2019-14164 G (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES WATER IS TO DRAIN AWAY FROM STRUCTURES FORA MINIMUM OF 5 FEETAT2 PERCENTAND BE CONVEYED TO ANAPPROVED DRAINAGE FACILITY UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BEAPPROVED BYTHE CITYENGINEER PRIOR TO ANY REQUESTFOR INSPECTION. 2 THE SOILS REPORT TITLED "PRELIMINARY GE07ECHNICAL INVESTIGATION, PROPOSED TWO STORY MIXED USE BUILDING COMMERCIAL AND RESIDENTIAL, 204 WEST J STREET ENCINITAS, CALIFORNIA- PREPARED BY COAST GEOTECHNICAL, DATED OCTOBER 15 2007, W.O. # P,519037, AND UPDATE REPORT TITLED "GEOTECHNICAL UPDATE PROPOSED MIXED USE DEVELOPMENT 204 WEST J STREET, ENCINITAS, CALIFORNIA, PREPARED BY HETHERINGTON ENGINEERING, INC, DATED MARCH 1, 2019 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL REDONE INACCORDANCE WITH THE RECOMMENDATIONSAND SPECIFICATIONS CONTAINED IN SAID REPORT 3. SEPARATEAPPROVALSAND PERMITS FORANYCONSTRUC77ON WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNC77ON WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6_ THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE REESTABLISHEDAND REPLACED BYA REGISTERED CIVIL ENGINEER ORA LICENSED LAND SURVEYOR. 7 THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATEAND FEDERAL SAFETYAND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (112) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 PM. AND 730A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITYAT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE THE DEVELOPER SHALL COMPLY iMTHALL CONDITIONSAND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11, UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING. 'THE GRADING UNDER PERMIT NO. 14164-G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE NTH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE ,AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECTAND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTSAND EKCAVATIONSAREACCEPTABLE FOR THEIR INTENDED USE 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PLACE SPREAD,,WATERANDCOMPACT THE FILL IN STRICTACCORDANCEWITHSPECIFICATIONS, 15. CUT AND FILL SLOPES SHALL BE CUTAND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED INACCORDANCE WITH THE GRADING ORDINANCE 16. ALL TREES BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OFANY SUCH MATERIAL. 17. THE REMOVAL OFANY ANO ALL CITY TREES SHALL BE CONSISTENT NTH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM TREES LOCATED W,-'i HIN CITY STREET RIGHT-OF-WAY ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUT�RMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IFA CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MU.7T BE PROTECTED 1N PLACE EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNI ESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT DIRECT OR TEMPORARILY HALT GROUND -DISTURBING ACTIWTIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY, THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIWTIESAREALLOWED TO RESUME. 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED ARCHAEOLOGIST AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THE CORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097,98, IF SUCH A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND/OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WTHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT 1F NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU rIN PLACE-), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. EROSION CONTROL I. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JAKE SCHULZ AT (760) 621-8751, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT 3 DEVICES SHOWN ON PLANS SHALL NOTCE MOVED OR MODIFIED 1MTHOUT THEAPPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO KORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5 THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAYARISE 6 THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE ORAREPOTENTIALLY UNSAFE. 7 ALL EROSION CONTROL MEASURES PROVIDED PER THEAPPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADEDAREASAROUND THE PROJECT PERIMETER MUST DRAINAWAY FROM THE FACE OF SLOPEAT THE CONCLUSION OF EACH WORK DAY 9 ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITYFORECAST EXCEEDS FORTY PERCENT (40%). SILTAND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP11MP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMPlMP FACILITIES ANWR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP1lMP FACILITYANDIOR THE TURFILANDSCAPEDAREAS 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMPIMP 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMPBMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFFAND DISCHARGE IT TO ANADEQUATE IMP /BMP 6 ALL STORMWATER IMPBMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7 THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATEENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NONCOMBUSTIBLE ROOF THAT WILL NOT ALLOW RAINWATER TO ENTER THE ENCLOSURE THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED MIEN NOT IN USE A BERM SHALL BE INSTALLED ATALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENTANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED VNDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIU GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. ASEPARATE BUILDING PERMITMAYBEREQUIRED FOR THIS STRUCTURE . SAN DIEGUITO WATER DISTRICT NOTES 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THEACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION 6YSAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND/OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6 MINIMUM HORIZONTAL SEPARA7ON OF 10-FEET REQUIRED BETWEEN FIRE HYDRANTSAND SAN DIEGO GASAND ELECTRIC VAULTS. 7 ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS WATER METERS MUST BE IN FRONT OF THE PARCEL THEYARE SERVING. 8 CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED NTH CATHODIC PROTECTION IN ACCORDANCE KITH WC-17OR WC-18. IMPERVIOUS AREA (ONSITE IMPERWOUSAREA PRIOR TO CONSTRUCTION: 3,379 SOFT IMPERVIOUS AREA AFTER CONSTRUCTION. 3,635 SOFT INCREASE IN IMPERVIOUS AREA: 256 SQFT 1MPERWOUSAREAREPLACED: 0 SQFT IMPERVIOUS AREA (OFFSITE IMPERVIOUSAREA PRIOR TO CONSTRUCTION1,975 SOFT IMPERVIOUS AREA AFTER CONSTRUCTION: 1,975 SQFT INCREASE IN IMPERVIOUS AREA: 0 SQFT IMPERVIOUSAREAREPLACED: 1,975 SQFT CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK -)AI-0- DESCRIPTION: 25" BRASS DISK LOCATION: THE TOP OF CURB ON THE SIDEVVALK QUADRANT OF THE INTERSECTION OF HIGHWAY 101 AND "J" STREET TYLER G LAWSON RECORD FROM. ENCINITAS CONTROL STATION OC-139 EDW4RD J. VVIMMER ELEVATION: 78.658' DATUM. NAVD88 CITY ENGINEER EARTHWORK DATA STEEPESTEXISTING NATURAL SLOPE ON -SITE = 20 H : 1 V MAXIMUM VERTICAL DEPTH OF CUT = 0.8' MAXIMUM VERTICAL DEPTH OF FILL = 0.9' CUT = 30 CY FILL = 70 CY IMPORT = 40 CY REMEDIAL = 500 CY AS -BUILT APPROVALS INT. DATE DATE PUBLIC WORKS PLANNING DATE REVIEWER INSPECTOR 1%TAMMfi1A[A TY-Pf ~%§ 1 11-11/%A1 AAA I -PM A/ MEAA ![/%TPA H1•■ A't'ra r� �w wwarw.�wr ■w�ew-r a w�r� rr�r�w CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISHAND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE 1T IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM ORANYRECEIVING WATER. CONTRACTOR SHALL POSTA SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE THIS SHALL INCLUDE USING MATERIAL SUCHAS 3" CRUSHED ROCKAND/OR CORRUGATED STEEL PANELSIPLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCHAS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATIONAND GRADING ACTIVITIESAREALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENTAND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OFTHE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY- THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUALAND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATIONAS SOONAS POSSIBLE, ONCE EXCAVATIONAND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION AIATERVIL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED NTH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETERATALL TIMES. TRAINING CONTRACTORS' EMPLOYEES W40 PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORSABOUT STORMWATER REQUIREMENTSAND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLYPROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMWIKE"S SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED W THIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED AITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195, FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENTAND LOCATE PORTABLE TOILETSAWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET GUTTER, AND STORMORAIN. CONTRACTOR MUST ROUTINELY CHECKAND CLEAN UP MATERIAL THAT MAY HAVE TRAVELEDAWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT CITY OF ENCINITASAT (760) 633-2770. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER' THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK 51TE IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWNG OVWERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATIONAND LOCATION OF UTILITIESAND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS-ENCINITAS SANITARYDISTRICT-(760) 633-2770 8 GAS & ELECTRIC - SDGE - (760) 438-62D0 C. WATER - SAN DIEGUITO WATER DISTRICT-1-800-227-2600 D. TELEPHONE - SBC BELL - (760) 489-3411 E CABLE TV - COX COMMUNICATIONS - (760) 806-9809X-2233 2 CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT PHONE (760)-633-2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760) 633-2770. ALL WORK PERFORMED V14THOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECRONAND REMOVAL. SHEET INDEX 1_ TITLESHEET 2. GRADING PLAN 3. SECTIONS & DETAILS 4. EROSION CONTROL PLAN PUBLIC WORKS 08.1. 1 S! N DATE DESIGNED BY. DRAWN BY CHECKED BY.' LSM LSM TGL PLANS PREPARED UNDER SUPERVISION OF DATE- - Z- R.C.E. NO.: 80356 TYWR G LAWSON EXP.: 12131120 ,0 pFESS/ z w No. 80356 � rExp. 12/31 /20 __Tj �1 CA 1F��`P OWNER 204 J STREET HOLDING LLC 620 2ND STREET ENCINITAS, CA 92024 ABP CAPITAL, LLC 8202ND STREET ENCINITAS, CA 92024 SITE ADDRESS 204-208 J STREET ENCINITAS, CA 92024 APN' 258-293-09-00 D M m zi t7 O > SITE, r- D � VII J ST EJST 0 Z C7 cn 4 PACIFIC W K ST OCEAN VICINITY MAP LEGAL DESCRIPTION NTS LOT 8 IN BLOCK 15, MAP OF ENCINITAS, IN THE CITY OF ENCINITAS COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 148, FILED IN THE OFFICE OF THE COUNTYRECORDER OF SAN DIEGO COUNTY. OWNER'S CERTIFICATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR IMLL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIWTYAND ADVISE ON THE COMPACTIQNAND STABILITY OF THE SITE I (VVE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITYS OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OFACTIONS, LOSSES DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE _PERMIT OR CONNECTED DIRECTLYOR INDIRECTLY TO THE PERMIT ORAPPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. - -------- - SIGNATURE. DATE - PRINT NAME: MICHAEL PERSALL THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY NTH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEERS TRADE OR PROFESSION THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HISMER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCYAND EMPLOYMENT ANDARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. SIGNATURE TYLW G LAWSON DATE PASCO, LARGT SUITER &ASSOCIATES 535N. HWY 101, SUITEA, SOLANA BEACH, CA 92075 PH: (858) 259-8212 SOILS ENGINEER'S CERTIFICATE MARK 0. HETHERINGTON, A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 10-13-07 AND FOR AN UPDATE ON 3-1-19. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS, RCEI CEG NO.: 304881397 EXP DATE 3-31-20 Wo. g 8786.1 HETHERINGTONENNGINEERING, INC. 5365AVENIDA ENCINAS CARLSBAD, CA 92008 PH. • (760) 931-1917 ASCC LARET SUITER & ASSOCIATES IL ENGINEERING + LAND PLANNING + LAND SURVEYING i North Highway 101. Ste A. Solana Beach, CA 92075 858.259.8212 1 ix 858.259.4612 plsaenglneering.com o.397 EXP. Date BMP PROJECT STATUS STANDARD PLANNING DIVISION PARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT SDVIV Vim W19-050 ' 9 i- s A AAA - G -' 64eq-- S f S 1,19 SIGN DATE SIGN DATE SIGN DATE SIGN DATE ENGIN RING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. RECOM ENDED: AP VED • _ GRADING PLAN FOR: ilw% - JESS NS �,z t DATE Ifod EDWARDJ.'p CITY GINE a DATL1 204 / 208 WEST J STREET APN:258-293-09 PLANNING CASE NO: 07-154 DR / TPM/CDP 3 to 7 - %o I l 5 04t- �4�fi4-�i SHEET 1 OF 4 PLSA .1095-01 40` �.. APPRX. LOCATION OF EX. 6"AC ` 20''' `� , EXISTNG 8" VCP SEWER EXISTING STREET WATER MAIN PER WO-5?-1 d , 10 10 MAIN PER CITY OF LIGHT TO REMAIN e_ APPRX. LO TLON OF EX. " r ENClNITAS DWG TM-4157-! GAS MAIN PER CITYOF \ v ENClNlTAS DWG TM-41574 APN. 25$ 293-10 APN: 258 293-07 EXISTING EDGE OF', LOT 10 PAVEMENT,� LOT 7 '`' '' " � � PROTECTEKIS77NG MAP 14$ 1 STA: 1+88.63 4.0' LT N WATER METER {N-PLACE SAP 148 EXISTING STRUCTURE To `EXISTING TREE t� CONNECT TO WG4TER MAIN ! - 2:1 TRANSITION Td EXISTING `\ Y FS=72.5 BE PROTECTED IN -PLACE PREVIOUSLY REMOVED BY CITY OF S 7 248'i r TA+8 .48 EDGE OF PAVEMENT � � ` � � = - - - _ � FG 73-3 FG-72.8 FS 73.4 � (!E 7 .87) FS 73 9 TG=73.3 19 )CAUTION! PRdTECT EX. FL 72 - IE=72.7 1 rG=73.21 1 14 _ 14 TG=72 65 FS=73.5 MO ME I • - % _,' '_.'__ _ 1 `72.3 FS 72.5 ;f : fN83°5 `16"E 100.71 1E r !E 7 . �. f- ... 0 STA: I ,� 0 FS CONNECT TO WATER M, ,N LA _ i' N >.'.... ......... T . STA. 1 84.63 4.2 LT _.... 77; A= •I - F-7.� , _ b p_ 102.0 CONNECT TO WATER MAIN :.:;:::::. _ _� ' . :....... �....: � . °..�� �. - 11 FS-74.4 FS 74 4:. F------------- S 73.5 .6 STA: 1+82.63 4. `LT ::'': •:': _ FS-74.0 LINE OF FLOOR FG=73.8 FG=72.7 CONNECT TO WATER AMAIN e' : , :_� - _.. 95+ _ i � ABOVE.(r? ?J . __ .. FS-73.7 a �G=73.7 Ca_ -fit F 0;_. STA: 1+72.58 7.0 RT : FS`�73 APPRX. LOCATION OF FxX ..'.. ISTALL SEWER LATERAL ::'`':{:::::::':'::.::' SEWER CLEANOUT 9 . �, FS=74.3 APN 58 293-09 1.7 R! -73.4;1-61.1..:. X. PALM .... - - SAGE LEVEL ;...::.:,,' _ r WX PALM :::::.:'..:::'.. FF=74.3 TREE TO BE - GRIND & OVERLAY TREETG-74.214 SEWER CLEANOUT TO REMAIN.:; , t f ' d �'.:•..:-''.'.:..:' - ��'.:::::...'.:" . _....:: r.,, REMOVED :,' :;:`':'.';:= : {.ups:'::: .. • PAD=73.6 REMOVED : !u IE=73.2 1STFLOOR 1 _ HALFVVIDTHPLUS 10' STA: 1+70.78 4.0 LT `'..,.':::�::�:;::�i:,:.::�:;�;';F•:'::':�' :� ; TC-73.7 ABANDON EX. WATER ::::': FG=74.3 TG=74.25 2 ' (FS=73.2j PER RESOLUTION - '' TSV1F-75.0 3 1 APN: 258-293-0$ SERVICE &METER ° IE=73.4 - IE=73.1 _ F�5`' .4 ` `=: - _ 11T=73.6 74.2 FS474.4Ar PAD=73.8 FG=73-3LOT 9 STA: 1¢�0.08 7.0 RT -::'.:ti:.:::':'::' :.....:'. ".:''.:'.;'.:•.':"TG74, TC-74.75 IE UT; pTC=74i9 5 ,.,:,.::'.Q :,.. 1 FG74.3 - ` :':::::'.�.FL=74.25 = .3 lE-73.1 - - MAP 148 INSTALL SEWER LATERAL �- FS-744 FS-73.45;. y ; RIM-73 �, IE=61.18-..:.55 - TG=74.2 3 FG=73.4 FS- - ..,a 1E=73.05 TC- 3 5 5 STA:1+67.58 70 RT :```:..:��:;:.::-:_ �•. ,'.�' :�':`:;��,::=:�:�:`; �� - FS=74.5 INSTALL SEWER LATERAL74 FS=74.3 RIM=73:6' I€=61.19 '.':.. � r �::..'.i:7: .. -. STA: 1+65.08 �7 0 RT <....:�, . � - .• a . _ ��-~� . -�- . � ��~ , .� 1 INSTALL SEWER LATE�2AL '...- o ...:.�� ,��»-#�A1i`#lI'� ;.�.� ; . ��4.3•- �� M �74. - . .,_ RIM=73.7; {E=61.0- _- G-73 FS=74. 3CAUTIO PROTECTEX 7. MONUIiiIENlN PLACE14 -�- -� TC=7 8• TG=73.7 T-73.7 lE 73 0 10�727 TC=75.7' FL=75.2 ttyy �-_ } w >� •� ° ° o N 3059'10`E ':100.69' 1 ° - TG-73.8 (1.0/D) - 15.0%) 3 �r, �' u, a - 1.4/ 530. ° TC.-74 9 -> 32 TC-74.5 - r ° �= - -¢ 6 ' 2.6% `:. 5=74.4 IE=73. I,; ' " FS-74.05 FS=74.0 . (17 - . a FS=74.84 TC=74.2 ° M,a, . E _ _ - X. ` EXIS77NG PCC °FS 75.0 TC-74.9 _.. 7) 12 PCC SIDEWALK ¢ (F5=73. SIDEWALK TO i FS=74.9 TC=74.55 z, a_ 99 12 x z REA MIN �'•_ �I. �' ;` �,' BMPAREA �C FS=74.05 EXISTING 6" PCC CURB & GUTTER TO REMAIN E~ (d CC cr, 6o W N V >` � cti E~ Do F- W Cr , Za o�w�� aWr�an Q. dimU� der -'�Lu ; i1.1 ii h it' } it QC� NLCryU o Q QZiLW x NNE �p 0 ��-- 6 .I ti" i b F Co O [' � a cry w w�� ri M + r w " w,` U v� cn �� � ti � ow€] U kL CONSTRUCTION NOTES O SDWD TO INSTALL 4" FIRE SERVICE PER WAS WF-05AT OWNER'S EXPENSE INSTALL FIRE SERVICE BACKFLOW PREVENTER BY VVlLKINS MODEL 375DA PER WAS WR-02. FIRE NOTE: IFANY MONUMENT IS DISTURBED OR DESTROYED SERVICE LINE TO SERVEALL UNITS, 2 RESIDENTIALAND 2 COMMERCIAL UNITS IT SHALL BE REPLACED RYA LICENSED LAND SURVEYOR AND A CORNER RECORD OR RECORD OF SURVEY SHALL 2 sD To { TALL 1) Sillifil LE NE COMMERC! L 1" W TER METER PER WAS S-O�lAfe BE FILED WITH THE COUNTY. Seh;_S��Fr INSTALL BACKFLOW PREVENTER BY WILKINS MODEL 975XL2 PER WAS WR-01. u 2v2. NOTE. ALL EXISTING ONSITE STRUCTURESAND VEGETATION TO BE REMOVED UNLESS OTHERWISE NOTED. NOTE. UTILITIES ARE KNOWN TO EXIST IN THEAREA, INFORMATION SHOWN HEREON IS PER BESTAVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONSTRACTOR SHALL NOTIFY ENGINEER OF WORK OFANY DISCREPANCIES BETWEEN ACTUAL LOCATIONAND PLAN LOCATION OF UTILITIES UPON DISCOVERY OF DISCREPANCY. CHANGE NO. DESCRIPTION P �lNL7 2of 3 D O I ALL 1 " ME W S ICEAND 314" METER PER WAS WS-01 FOR EACH UNIT; RESIDENTIAL UNIT 201, 202 ® SEVER LATERAL TO BE EXTENDED FROM NEW CLEANOUT TO NEW RESIDENCE WITH 4" PVC INSTALL 4" PVC SEWER LATERAL PER SDRSD SS-01; RELOCATE SEWER CLEANOUT PER SC-01 0 INSTALL 4" PVC SEWER LATERAL WITH CLEANOUT PER SDRSD SS-01 AND SC-01 ® INSTALL 4"AC OVER 6" CLASS !I AB OR PER GEOTECHN{CAL RECOMMENDATIONS (D INSTALL 3' WIDE PCC RIBBON GUTTER PER DETAIL SHEET ® INSTALL 5.5" THICK MIN. PCC DRIVEWAY OVER 3" CLASS I{AB PER GEOTECHNICAL RECOMMENDATIONS APPROVED I DATE 4+50 O it tk. N � 1 O �I i GRADING PLAN CONSTRUCTION NOTES O SDWD TO INSTALL 4" FIRE SERVICE PER WAS WF-05AT OWNER'S EXPENSE INSTALL FIRE SERVICE BACKFLOW PREVENTER BY VVlLKINS MODEL 375DA PER WAS WR-02. FIRE NOTE: IFANY MONUMENT IS DISTURBED OR DESTROYED SERVICE LINE TO SERVEALL UNITS, 2 RESIDENTIALAND 2 COMMERCIAL UNITS IT SHALL BE REPLACED RYA LICENSED LAND SURVEYOR AND A CORNER RECORD OR RECORD OF SURVEY SHALL 2 sD To { TALL 1) Sillifil LE NE COMMERC! L 1" W TER METER PER WAS S-O�lAfe BE FILED WITH THE COUNTY. Seh;_S��Fr INSTALL BACKFLOW PREVENTER BY WILKINS MODEL 975XL2 PER WAS WR-01. u 2v2. NOTE. ALL EXISTING ONSITE STRUCTURESAND VEGETATION TO BE REMOVED UNLESS OTHERWISE NOTED. NOTE. UTILITIES ARE KNOWN TO EXIST IN THEAREA, INFORMATION SHOWN HEREON IS PER BESTAVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONSTRACTOR SHALL NOTIFY ENGINEER OF WORK OFANY DISCREPANCIES BETWEEN ACTUAL LOCATIONAND PLAN LOCATION OF UTILITIES UPON DISCOVERY OF DISCREPANCY. CHANGE NO. DESCRIPTION P �lNL7 2of 3 D O I ALL 1 " ME W S ICEAND 314" METER PER WAS WS-01 FOR EACH UNIT; RESIDENTIAL UNIT 201, 202 ® SEVER LATERAL TO BE EXTENDED FROM NEW CLEANOUT TO NEW RESIDENCE WITH 4" PVC INSTALL 4" PVC SEWER LATERAL PER SDRSD SS-01; RELOCATE SEWER CLEANOUT PER SC-01 0 INSTALL 4" PVC SEWER LATERAL WITH CLEANOUT PER SDRSD SS-01 AND SC-01 ® INSTALL 4"AC OVER 6" CLASS !I AB OR PER GEOTECHN{CAL RECOMMENDATIONS (D INSTALL 3' WIDE PCC RIBBON GUTTER PER DETAIL SHEET ® INSTALL 5.5" THICK MIN. PCC DRIVEWAY OVER 3" CLASS I{AB PER GEOTECHNICAL RECOMMENDATIONS APPROVED I DATE 4+50 O it tk. N � 1 O �I i GRADING PLAN 9 f 1 F ` 73.3 {E=72.9 1295' � � 6 F ' G 2 TC-74:1 ° (1.0%) , - Fs 73:6 12 , D 18 IE OUT=72.6 FG ' I F` STA 7+46.76.25.0' LT: (IE=72.7) 2ND ST STA: 7+39.97, 25.0' LT ECR; MATCH EX. CURB & GUTTER (TC=73.35); (FL=72.85) 2ND ST STA: 7+35.75. 25.6' LT ` TC=73.38; FL=72.88 INSTALL TYPEA CURB RAMP PER SDRSD G-27; SEE DETAIL SHEET FS=72.95 I ITEM STD, DWG SYMBOL SUBDIVISION BOUNDARY ADJACENT PROPERTY LINE / RIGHT-OF-WAY PROPERTY SETBACK CENTERLINE OF ROAD EXISTING EASEMENT PROPOSED BUILDING FOOTPRINT STEM WALL PERARCH DEEPENED FOOTING PER ARCH GRADE LIMI T LINE W PROPOSED FLOW LINE CONSTRUCT 6" PCC CURB & GUTTER SDRSD G-02 CONSTRUCT 6" PCC CURB SDRSD G-01 PROPOSED CONTOUR LINE 75 EXISTING CONTOUR LINE _..._... _ . ... _ _ .._ . _... _.............. EXISTING EDGE OF PAVEMENT INSTALL 4" PVC STORM DRAIN PIPE INSTALL 3 PVC SIDEWALK UNDER DRAIN SDRSD D-27 -•-• - _ --- - - - - - - - - SAWCUT GRIND & OVERLAY GRIND &OVERLAYMMKM��_zm INSTALL 4" FIRE SERVICE WF--05, VVR-02 W W WITH BACKFLOW INSTALL 1" COMMERCIAL WS-01, VVR-01 W W SERVICE WITH BACKFLOW INSTALL I" DOMESTIC SERVICE WS-01 W vv MTH 314" METER INSTALL 4" PVC SEWER LATERAL SDRSD SS-01 S CONSTRUCT BMP BASIN PER DETAIL SHEET 3 INSTALL PERVIOUS PAVERS PER DETAIL SHEET 3 CONSTRUCT PCC FLATWORK ° b (THICKNESS PER PLAN) INSTALL 12"X 12" GRATED INLET NDS OR EQUAL INSTALL 6" DIA. AREA DRAIN NDS OR EQUAL 0 EXISTING WATER MAIN -.-- ---__ Vf EXISTING SEWER MAIN _._.._.............._._.... __........._..._...-- EXISTING WATER METER �.._._.._' EXISTING STREETLIGHT EXISTING SURVEY MONUMENT ABBREVIATIONS FS = FINISHED SURFACE FG = FINISHED GRADE GF = FACE OF GARAGE ELEVATION SCALE: 1 "=10' TC = TOP OF CURB IE = INVERT ELEVATION TG = TOP OF GRATE ® INSTALL 4" THICK PCC HARDSCAPE OVER 4" CLEAN SAND OR PER GEO TECHNICAL 20 SDWD TOABANDON EXISTING 314" COPPER WATER S1=RVICEAND 518" WATER METER TSW= TOP OF STEM WALL RECOMMENDATIONS 21 {IifSTALL PCCALLEYAPRON PER SDRSD G-17 10 INSTALL PERVIOUS PAVERS PER DETAIL SHEET 3 22 SAWCUT EXISTING AC PAVEMENT SEE DETAIL SHEET 3 11 INSTALL 6"X 16" PCC FLUSH CURB ENCROACHMENT MAINTENANCE 23 INSTALL 3" PVC SIDEWALK UNDER DRAINPIPE PER SDRSD D-27 AND REMOVAL AGREEMENT 12 INSTALL 6" PCC CURB PER SDRSD G-01; DEEPEN CURB AS NECESSARY TO EXTEND BENEATH DOC #: COI 1 - O la IZ57 PAVER SECTION 24 EXISTING PCC SIDEWALK TO REMAIN, CONTRACTOR TO REMOVEAND REPLACE PORTIONS OF DAMAGED SIDEVVALKAS NECESSARY TO THE SATISFACTION OF THE CITY ENGINEER. SIDEWALK DATED: ss elm�I l9 13 INSTALL 6" CURB & GUTTER PER SDRSD G-02 SHALL BE SCORED WITH THE TWO -FOOT BY TWO -FOOT SCORE PATTERN TO MATCH THE EXISTING 14 INSTALL 6"AREA DRAIN BY NDS OR APPROVED EQUAL 25 CONSTRUCT TYPEA PCC CURB RAMP PER SDRSD G-27, SEE DETAIL SHEET SCALE: 1 " = 10' 15 INSTALL 12"X 12" GRATED INLET WITH CAST IRON GRATE BY NDS PART NO.1213 OR APPROVED 26 CONSTRUCT MODIFIED TYPED PCC CURB RAMP PER SDRSD G-31; SEE DETAIL SHEET 3 EQUAL 16 INSTALL 4" PVC STORM DRAIN PIPEAT 1 % MIN SLOPE 27 CONSTRUCT STEM WALL PER SEPARATE PLAN 28 CONSTRUCT DEEPENED FOOTING PER SEPARATE PLAN 17 INSTALL MODIFIED CUTOFF WALL PER DETAIL SHEET GRIND & OVERLAY TO ENSURE POSITIVE ..... ...... DRAINAGEFROM CENTERLINE TO GUTTER t1 ui t` er c•j o ri ............ Co it � i n Lu w , w ti I W �I 10 S 0 10 20 Q�of ESS lo�v �o �R c L�q� � �`,�" 18 CONSTRUCT MODIFIED PCC CUTOFF WALL PER DETAIL SHEET 3 WITH 2'X 2' COBBLE D{SSIPATOR 29 CONSTRUCTALLEYAPRONPFR SDRSD G-17 � 30 EXISTING STREET SIGN TO BE PROTECTED IN PLACE w No. 80356 19 EXISTING SURVEYMONUMENT TO BE PROTECTED IN -PLACE. IF MONUMENT IS DISTURBED OR Exp. 12/31 /20 DESTROYED, IT SHALL BE REPLACED BYA LICENSED LAND SURVEYOR ANDA CORNER RECORD 31 INSTALL 6" STORM DRAIN CLEANOUT? OF SURVEY SHALL BE FILED WITH THE COUNTY ,S j C! V � �Q 32 INSTALL 4" EMERGENCY OVERFLOW RISER /ATRIUM GRATE 0PW0JffP? rMAER AM W FW F0. WA� W01 i Wj� �jF O,c CAS PASCO LARET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 Forth Mghway 101, Ste A, Soiaaa Beach, GA 92075 ph 858.259.8212 I fx 898.289AS12 I Phs - &cm BENCHMARK AS -BUILT APPROVALS DESIGNED BY DRAVVN BY' CHECKED BY: ENGINE I G IVISIONAPPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT LSM LSM TGL DESCRIPTION.' 2.5" BRASS DISK LOCATION: THE TOP OF CURB ON THE SIDEWALK QUADRANT OF INT DATE PLANS PREPARED UNDER SUPERVISION OF DATE. Y -? - hi _ R.C.E. NO.: 80356 TYLERGLAWSON EXP: 12/31/20 RECOM ENDED: APP OVED: JESSE WENS EDWARD J. M. R �J /e A CrTYEGW o� Ij p -`D----ATTEE�= �- DATEI GRADING PLAN FOR: 204 / 208 WEST J STREET 204 J STREET HOLDINGS' LLC APN: 258 293-09-00 PLANNING CASE NO.07-154DR/TPM/CDP 3117-tat 506aL- PUBLIC WORKS TYLER G LAWSON DATE THE INTERSECTION OF HIGHWAY 101 AND 7' STREET PLANNING RECORD FROM:. _ENCINITAS CONTROL STATION OC-139 ..._ :....: ELEVATION. 78,658 DATUM: NAVD88 EDWARD J. WIMMER DATE C17YENGINEER REVIEWER INSPECTOR DRAINING NO. 14164-G SHEET 2 OF 4 PLSA 3095-01 r J R WEST J STREET 80' 40' 40' 15E V LANDSCAPE 5 g 25' TO FC 25' TO FC STRIP SIDEWALK PARKWAY EXISTINGAC VARIES VARIES PAVEMENT VARIES --- -- - € i I EXISTING PCC SIDEVALK TO " w E ` I ; -_ I _ - -- - - PCC PROPOSED 6 - �_. _ -._ - - r -�� REMAIN CURB &GUTTER PER PROPOSED 2"--- SDRSO G 2 GRIND & OVERLAY TYPICAL SECTION - WEST J STREET NOT TO SCALE R 2ND STREET 800' ' Y 40' 40' 15, 1 `LANDSCAPE 5f 9` 25' TO FC 25' TO FC STRIP SIDEWALK PARKWAY VARIES GRIND & 10' EXISTINGAC VARIES OVERLAY VARIES PAVEMENT EXISTING PCC SIDEVV4LK TO \41 .; `- -"� EXISTING CURB &v_- _ �-- •=-�._- _ -�`"` _ .___ __ _ _ . REMAIN GUTTER TO REMAIN m LIMIT GRIND & OVERLAY OF EXISTINGAC PAVEMENT TYPICAL SECTION - 2ND STREET NOT TO SCALE , , ' ••. - _' _. .•. -.3..' ". - - S' • --1_• `i 1 €•i • ' : e i f - _7-/,4am,-ka . 1 • - - _ - Imo, TC-74.� s i FS=74:3 i a V . A i" "" o i ' t .:.� 'mil •�.--� -��_ ' zf•-`7.-.'" ' r , Q- i.J.• '£ - • .f' . ... .. .•-' .. 3, -•--•=w•;-"' E :l :�s3_ 1;' - I 1 FS=74 4 f=74 i TC=7538TG=7497 o FL=74.88 fl�4�� FS=74.97 a FS=74.92 D FS--74,5 �FS=74 2. a MATCHEX. _ V /V PCC SIDEMK ! 4 J ' f FS=74.84 o TC=75.3# o TC=74.9 � , FS=74.3 I FL=74.8 TC=75.1 FS=74. r INSTALL YELLOW FS=74.6 TRUNCATED DOMES SDRSD GIGO 4.0'X 5.0' f TC=74.8 LANDING TC=74.1 o FS=74.3 BRISBANE BOX CITY FS=73.6� o , ' STREET TREE(TYR) N _ ':•:.:, �.... u: WEST J STREET _ TYPICAL DETAIL - G-31 TYPE D CURB RAMP NOT TO SCALE 15' PARKWAY VAS EXISTING CURB & \- EXISTING GUTTER TO REMAIN DECORATIVE PAVER WALKWAY TO REMAIN 15' PARKWAY VARIES .............- - --- UIS77NG CURB & -- GUTTER TO REMAIN EXISTING PCC SIDEWALK TO REMAIN IN 2NDT STA: 7+39.97 25.OLT 4 EXIST MATCH EX. CURB & GUTTER FS=73.41 (TC=73.35); (FL=72,85) F=7 _49 FL=73.53 FSi73.43 0 ' 2ND ST STA: 7+3575 25.E TC=73.W; FL=72.88 QZ MATCH EXIST.; S FS=73.47 oR - 2ND ST STA.- 7+29.36 29.4' LT t INSTALL TYPEA CURB RAMP PER --- - - - 4 --- SDRSD G 27 WITH YELLOW DOMES PER G-30; FS=72.95 FL=72.97 WESTJST STA: 5+13.45 25 3 LT TC=73.53, FL=73.03 ' TYPICAL DETAIL - G-27 TYPEA CURB RAMP NOT TO SCALE APPROXIMATE LOCATION OF EXISTING GAS MAIN APPROXIMATE LOCATION OF EXISTING SDKD 6"ACP WATER MAIN PER WO-52-1 10, 10` INSTALL NEW PCC RIBBON GUTTER PER DETAIL THIS SHEET 2.0% 2Y0% INSTALL 4"AC OVER 6" CLASS IIAB OVER { NATIVE SUBGRADE COMPACTED TO 95% REL. COMP OR TO SATISFACTION OF CITY ENGINEER OR GEOTECHNICAL ENGINEER RECOMMENDATIONS APPROXIMATE LOCATION OF EXISTING 8"VC SEWER MAIN PER CITY OFENCINTAS DWG TM-4157-1 TYPICAL SECTION - ALLEY W DRAIN PIPE °ER PLAN) DASHED LINE REPRESENTS EXISTING/PROPOSED GRADEAT INVERT 'CC CUTOFF AALL HICKNESS=6" ! TYPICAL DETAIL MODIFIED CUTOFF WALL NOT TO SCALE 3.0' X" OF SUBGRADE PER GEOTECH RECOMMENDATIONS FS=FL + 0.1' FL=PER PLAN 3.0' MIN 201MIN COLD PLANEAND OVERLAY (2" MIN DEPTH) TO PROVIDE SMOOTH TRANSITION INSTALL 6" PCC CURB & GUTTER EXISTINGAC PER SDRSD G 2 PAVEMENT Q 4 STRUCTURAL SECTION NEW �0 4"AC OVER 6" CLASS II AB OVER NAT#VE SUBGRADE EXTFND BASE COMPACTED TO 95% REL. COMP. 6"BEHIND CURB TYPICAL SECTION - SAWCUTAC PAVEMENT NOT TO SCALE 6"X 16"PCC FLUSH CURB OR DEEPENED G-1 CURB VOID FILL ERe"TO! 8"(N0.8) APPROVED PERVIOUS AGGREGATE IN VOIDS PAVERS W/ MIN. $ "VOID BEDDING COURSE 2" THICK OF-!" e TE a N0.8 AGGREGA - 6 Q 'a A d F 3" COURSE-4 - CHOKER coU -4 " THICK of -� s 4 TO2"(NO.57) CRUSHED ROCK II 611 I MIN. 6" THICK OF a CRUSHED ROCK SOIL SUBGRADE��- NOTE: ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEENADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRNN MAY BE REQUIRED TYPICAL DETAIL - PERVIOUS PAVERS NOT TO SCALE NOT TO SCALE SOIL J - - X MDE, 6" THICK PCC SUBGRADE RIBBON GUTTER, 560-C-3250 CONCRETE TYPICAL SECTION - AC ALLEY & PCC RIBBON GUTTER NOT TO SCALE 2" LAYER OF Fr=PFR P1 AN HARDWOOD MULCH INSTALL 4"AC OVER 6" CLASS II AB OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP. OR TO SATISFACTION OF CITYENGINEER OR GEOTECHNICAL ENGINEER RECOMMENDATIONS 4" PVC EMERGENCY OUTFLOW PIPE I , 18" LAYER OF ENGINEERED SOIL; MINIMUM INFILTRATION -._ ----- RATE OF 5 INCHES PER HOUR, - -- --- SEE NOTE BELOW - .. 3" LAYER OF PEA GRAVEL 9" LAYER OF 314" WASHED, BQTTOM OF BASIN; CRUSHED STONE LAYER {NO EL=FG PER PLAN MINUS 2.5' RECYCLED MATERIAL) *BIOFILTRATION "ENGINEERED SOIL "LAYER SHALL BE EVENLY MIXED COMPOSITION OF GASHED SAND, SANDY LOAM TOPSOIL, AND HUMIC COMPOST. THE MIX SHALL CONTAIN 65% SAND, 20% TOPSOIL, AND 15% COMPOST OR HARDWOOD MULCH IN ACCORDANCE VWTH COUNTY OF SAN DIEGO LID BIOSWALE MEDIA B1065 CUT SHEET !f " ''3/4 CRUSHED ROCK LAYER SHALL BEA MIN#MUM OF 6 BUT MAY BE DEEPENED TO INCREASE THE INFILTRATIONAND STORAGEABILITY OF THE DETAIL TYPICAL SECTION - BIORETENTION BASIN NOT TO SCALE QRpFESSIOy �Q ?GLq "9! w tb. 80356 � Exp. 12/31 /20 'qT£ OF CAS-�F� PASCO LARET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 533 Notch EMShmay 103, Ste A, Sol=& Heach, CA 92075 ph 898.2ff.8212 I fz 6U.MA812 000z ffI CHAN(3EN0. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY DESI DRAWN BY CHECKED BY. - ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. LSM LSM TGL AN AM -Whfa SEPA5DESCRIPTION: 2.5" BRASS DISK LOCATION" THE TOP OF CURB ON THE SIDEWALK UADRANT OF THE INTERSECTION OF HIGHWAY 101 AND "J" STREET INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE T -1-0 R.C-E NO.: 80356 TYLER G LAWSON EXP.. 1031/20 RECO ENDED: AP VE JES OWENS EDVV4RD J. VVIM CITYENGIN -F CL DATE LffTE SECTIONS & DETAILS FOR: 204 / 208 WEST J STREET 204 J STREET HOLDINGS LLC ' APN. 15S 293-09-00 PLANNING CASE NO: 07-154 DR / TPMI CDP Ks 11 Y - To 19 S V eL i4 G4 G PUBLIC WORKS TYLER G LAWSOIV DATE PLANNING RECORD FROM.' E�NCINITAS CONTROL STATION OC-139 ELEVATION. 78.658' DATUM: NAVD88 EDWARD J. AIMMER DATE CITY ENGINEER REVIEWER INSPECTOR SHEET 3 OF 4 PLEA 3095 01 i_40Y- 3 ::•:':' p e � e _ �_ ......... • :: SILT FENCE PER I DETAIL D THIS SHEET 4 GRAVEL BAGS PER DETAIL B THIS SHEET :::'. :::...... :. ........... :::-':........ CONSTRUCTION GRAVEL BAIL INLET" Q �:`.:.E•.::•:.::;:.:':':_'':•:': ENTRANCE PER DETAIL PROTECTION P ::: THIS SHEET B THIS SHEET (TYP) e SILT FENCE PER DETAIL D THIS SHEET GRAVEL BAG INLET -PROTECTION PER DETAIL B THIS SH1=ET (TYP.) f � _ (� F GRAVEL BAG INLET PROTECTION PER DETAIL B THIS SHEET(7YP.) a r., EROSION CONTROL PLAN SCALE: 1"=10' WEST J STREET 16.0' ROW APN.' 258-293-10 J.7` I 11.3' Offer 5.0' - COMMERCIAL BUILDING A LEVEL 1 FS=74.5 APPROX. LINE OF A FF=74.5 TC=74.05 EXISTING GRADE PAD=73.8-y FG=73.3 FG=73.55 FS=73.5 - EXISTING STRUCTUREAT 7,77 FG=72.6 .. - PROPERTY LINE TO BE E-- PROTECTED IN PLACF :: _ : € e i i i f f t , i mmmmW � � ._�� 3"PVC SIDEWALK UNDER INSTALL 6" PCC CURB PER ._... =" LANDSCAPE PLANS; DEEPEN INSTALL BMP BASIN DRAIN PIPE OVERFLOW INSTALL 4" PVC STORM CURB TOAVOID SURCHARGE PER DETAIL SHEET 3 FROM BMP PER PLAN DRAIN PIPEAT 1 % MIN ON BMP BASIN INSTALL 6" PCC CURB PER EXISTING PCC INSTALL 6"X 16" PCC FLUSH - LANDSCAPE PLANS, DEEPEN SIDEWALK TO REMAIN CURB; DEEPENAS NECESSARY CURB TO EXTEND 6" MIN FOR 1' MIN EMBEDMENT BENEATH BMP BASIN DESILTING BASIN NOTE: BIORETENTION BASINS Sr ALL BE EXCAVATEDAND USEDAS DESILTING BASINS DURING CONSTRUCTION. THE SILT SHALL BE COMPLETELY REMOVED, BOTTOM SCARIFIED IF NECESSARYAND THE BIORETENTION BASINS COMPLETED ONCE FINAL SITE STABILIZATION ISACHIEVED, PRIOR TO OCCUPANCYAND / OR FINAL NOT TO SCALE APN: 258-293-10 ',� i 8.51 APPROX. LINE OF EXISTING GRADE FG=73.3 EXISTING STRUCTUREAT FS=73.6 GARAGE LEVEL ? PROPERTY LINE TO BE LANDSCAPE FF 74.3 PROTECTED IN -PLACE f AREA ^ - - - - - - - -, PAD=73.6 . ....... k CHANGE NO, I DESCRIPTION I APPROVED _ E ; INSTALS_ DEEPENED FOOTING PER INSTALL 4" PVC STORM SEPARATE PLAN DRAIN PIPEAT 1 % MIN INSTALL PERVIOUS INSTALL 6" X 16" PCC PAVERS PER DETAIL FLUSH CURB SHEET 3 SECTION C NOT TO SCALE DATE BENCHMARK DESCRIPTION: 2.5" BRASS DISK LOCATION: THE TOP OF CURB ON THE SIDEWALK -QUADRANT OF TYLER G LAWSON THE INTERSECTION OF HIGHWAY 101 AND "J" STREET RECORD FROM. ENCINITAS CONTROL STATION OC-139 EDWARD J. WIMMER ELEVATION: 78.658' DATUM: NAVD88 CITYENGINEER 1 3" TO 6" COARSE AGGREG/ PLAN i PROVIDEAPPROPRIATE TRANSITION -- BETWEEN STABILIZED CONSTRUCTION ENTRANCEAND PUBLIC RIGHT -OF- WAY *LESSER DISTANCEALLOWED WITH C17YINSPE'CTORAPPROVAL DETAILA: CONSTRUCTION ENTRANCE NOT TO SCALE NOTE: CONTRACTOR TO MODIFY CONSTRUCTION ENTRANCE IN THE FIELD AS NECESSARY CONSTRUCT SEDIMENT BARRIERAND CHANNELIZE RUNOFF TO SEDIMENT TRAPPING DEVICE SCALE: 1 " = 10' 0 5 0 10 20 31 1. SET POSTS AND EXCAVATE 4 BY4 IN (10 BY 10 CM) TRENCH UPSLOPE FROMAND ALONG THE LINE OF POSTS. 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCEAND EXTEND IT INTO THE TRENCH. RUNOFF GAP BETV ACTS AS SPILLWAY 2. STAPLE WIRE FENCING TO THE POSTS. 4 IN (10 CM) 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. FILTER FABRIC WIRE s� LAYERS OF GRAVEL BAGS WITH ENDS n1=01 nnncn NOT TO SCALE EROSION CONTROL LEGEND CONSTRUCTION ENTRANCE PER DETAIL TR-1 RZ2= GRAVEL BAGS PER DETAIL 8 SE-4, 5E 6, S� 10 SILT FENCE PER DETAIL D SE-1 n n n FIBER ROLL DETAIL C SE-5 FR - HYDROSEEDING EC-4 x x x x x x x x x x x i r / FIBER ROLLS, SPACING MEASURED %/'';'/°/'�'' -V ALONG FACE OF THE SLOPE VARIESPER TABLE BELOW I y INSTALL A FIBER ROLL NEAR SLOPE WHERE IT TRANSITIONS INTO TYPICAL FIBER ROLL INSTALLATION A STEEPER SLOPE NOT TO SCALE FIBER ROLL t , 8" MIN �3/4" X 314" WOOD STAKES MAX 4' SPACING DETAIL v FIBER ROLLS FIBER ROLL SPACING TABLE (PLACED ON LEVEL CONTOURS) SLOPE INCLINATION HORIZONTAL INTERVAL 4: ? (H:Vj OR FLATTER 20 FEET (MAXIMUM) BETWEEN 4'?AND 2.'1(H. Vj 15 FEET (MAXIMUM) 2: ? (H: V) OR STEEPER 10 FEET (MAXIMUM) NOT TO SCALE STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO DETAIL D: SILT FENCE CONSTRUCTION ACTIVITIES (CONT'D FROM SHEET 1) NOT TO SCALE ON -SITE CONSTRUCTION ON rE NSTRLJ rION MATERIAL STORAGE V NT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PRE E O STAY DRY OUT OF THE RAIN CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE , ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED IMTH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES . WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED, NOSEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS t 0 DIVERT C WEST J STREET THE NATURAL STORM RUNOFF DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. 20.2' DUMPSTERS VVITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN ROW CONTACT WITHANY TRASH MATERIAL. 6.7' 6.0' 7.5' 1,O I 5.0` MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND INSTALL STEM APPROX. LINE OF CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS WALL PER HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195, TC=74.8 EXISTING GRADE FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCOAT (760) 436-4151. SEPARATE PLAN FS=74.3 GARAGE LEVEL 1 FS=74.3 TC=74.85 POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANSAND RECYCLING RECEPTACLES AROUND THE SITE. - - FF=74.3 - - - - - --- __- - - _ � FG=73.35 FS=73.3 PAD=73, 6 -� .. ^ L - - - - PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS, CONTRACTOR SHALL PROVIDE SECONDARY N . 9 CONTAINMENTAND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. FG=73.3 = _..._.. _� _ FG73.4 sGUTTER,D STORMDRAIN CONTRACTOR MUST ROUTINELY CHECK AND CLEAN - E E zE _ UP MATERIAL THAT MAY HAVE TRAVELEDAWAY FROM CONSTRUCTION SITE E PCC FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, EXISTING SIDEWALK TO REMAIN CITY OFENCINITAS A ( ) 33-2770 r7606 DEEPEN FOOTING AS NECESSARY TO AVOID �pF ESS/O APPROX. LINE OF 4.9' EXISTING GRADE COMMERCIAL BUILDING `FG=72.8) LEVEL 1 FS=74.0 FF=74.5 PAD 73.8 INSTALL DEEPENED w '! FOOTING PER SEPARATE PLAN INSTALL PERVIOUS PAVERS PER DETAIL SHEETS NOT TO SCALE SURCHAGE ON BMP BASIN INSTALL 6" PCC CURB INSTALL BMP BASIN INSTALL 6" PCC CURB PER �p e�R G L q ; 9! INSTALL BMA BASIN PER LANDSCAPE PLANS, PER DETAIL SHEET 3 LANDSCAPE PLANS, DEEPEN =' �� `�� - <"y DEEPEN CURB TO CURB TO EXTEND 6" MIN o PER DETAIL SHEET z EXTEND 6" MIN BENEATH BENEATH BMP BASIN 0 m BMP BASIN � EXp 01 1 /20 2 AS -BUILT APPROVALS INT DATE DATE PUBLIC WORKS PLANNING DATE REVIEWER INSPECTOR P• SECTION D �Tq CIVI\- NOT TO SCALE TF OF CA�-�F DESIGNED BY.' DRAWN BY CHECKED BY: LSM LSM _ TGL PLANS PREPARED UNDi-R SUPERVISION OF DATE, i'- f' ,f R.C.E: NO.: 80356 TYLER G LAWSON EXP: 12131120 PASCO LARET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 North ;I %hway 101. Ste A, Solana Burch. CA 92075 ph BSL259.8213 j fs 856.259.4812 ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. RECOMMENDED: VE®: [.--� EROSION CONTROL PLAN FOR. 20 / 208 WEST J STREET 14164-G JEs OWENS EDWARD d. WIMM 204 J STREET' HOLDINGS, LLC CITYE GINEE APN: 258-29-09-00 �A19 '10 DATE DAT PLANNING CASE NO: 07-154 DR / TPM / CDP % t 11- z 0141 s 0 8 c SHEET 4 OF 4 PLSA 3095-01 F ED � � N ti LQ �CO04 w a amid, N