Loading...
2020-13765 G (Plans)RIGHT OF WAY NOTE EROSION CONTROL STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES OWNER DLS HOLDINGS LP, OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT DANIEL FRYE AT (858) 401-2292, 24 HOURS A DAY. CONCRETE WASHOUT 2047 SAN ELIJO AVE. PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE CONTRACTOR SHALL ESTABLISHAND USE AN ADEQUATELY SIZED CONCRETE CARDIFF, CA 92007 RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE PERMITTEE DRAINAGE NOTE LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. WASHOUT LOCATION. LEIGHTON R. FRYE DLS HOLDINGS LP, m NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. CONSTRUCTION SITE ACCESS 2047 SAN ELIJO AVE. SITE ym� T FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF CARDIFF, CA 92007 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCKAND/OR CORRUGATED STEEL PANELS/PLATES. (858)401-2292 �m , UTILITY NOTE ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. �m CONSTRUCTION VEHICLES -o uN N 0 ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE SITEADDRESS G DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAYARISE. REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. 555 & 571 N. VULCAN AVE. 0 c, GENERAL NOTES ENCINITAS, CA 92024 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS EROSION CONTROL APN: 256-090-06 & 07 m �� 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST �Z THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. BONDED FIBER MATRIX. LEGAL DESCRIPTION NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. 2. THE SOILS REPORT TITLED "LIMITED GEOTECHNICAL INVESTIGATION AND INFILTRATION TESTING FOR LID FEASIBILITY, VULCAN 16," 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT THAT PORTION OF LOT 11 OF LEUCADIA ACRES, IN THE COUNTY OF SAN DIEGD STATE OF VICINITY MAP PREPARED BY CW LA MONTE COMPANY, INCORPORATED, DATED SEPTEMBER 11, 2018, SHALL BE CONSIDERED AS A PART OF THIS GRADING EACH WORK DAY. CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. CALIFORNIA ACCORDING TO MAP THEREOF NO. 1704 FILED IN THE OFFICE OF THE COUNTY PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID RECORDER OF SAID COUNTY, JULY 5, 1918, MORE PARTICULARLY DESCRIBED IN GRANT DEED NTS 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE RECORDED NOVEMBER 4, 2020, DOCUMENT NO.2020-0688048, O.R. (APN 256-090-07) 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH EROSION. CONJUNCTION WITH IMPROVEMENT PLANS. RAINFALL. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION THE NORTHWESTERLY 50 FEET OFALL THAT PORTION OF LOT I I OF LEUCADIA ACRES IN THE CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 1704, FILED 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. BIND THE SOIL. IN THE OFFICE OF THE COUNTY RECORDER OF SAID SAN DIEGO COUNNY, JULY 5, 1918, MORE PARTICULARLY DESCRIBED IN GRANT DEED RECORDED NOVEMBER 4, 2020, DOCUMENT NO. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. 2020-0688048, O.R. (APN 256-090-06) OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF RE-ESTABLISHED AND REPLACED BYA REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET ON -SITE CONSTRUCTION MATERIAL STORAGE ANDIOR INTO THE PUBLIC STORM DRAIN SYSTEM. STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE SOILS ENGINEER'S CERTIFICATE 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL FOR CONFORMING TO ALL LOCAL, STATEAND FEDERAL SAFETYAND HEALTH STANDARDS, LAWS AND REGULATIONS. STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, I, CLIFFORD W. La HAN C A REGISTERED CIVIL ENGINEER IN THE STATE OF OF TH SOIL PRINCIPALLY DOING BUSINESS IN THE FIELD A 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS PERMIT FROM THE CITY. PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MADE BY ME O UNDER MY DIRECTION ON SUBMITTED 15, THE ONE COMPLETE COPY G THE SOILS REPORT COMPILED FROM THIS STUDY, CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL APRE-CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING THEAPPROVED BMP/IMP FACILITYAND/OR THE TURF/LANDSCAPED AREAS. TRAINING PEOPLE PRESENT CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY MEETING SHALL BE SCHEDULED WITH THE CITYAT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SIGNED: 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM CLIFFORD W. La MONTE THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE AND THEIR OWN RESPONSIBILITIES. DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE RCE NO.: 25241 FFSFESS/F FCZFEESS SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. SYSTEM THAT IS DESIGNED TO COLLECT RUNOFFAND DISCHARGE IT TO AN ADEQUATE IMP /BMP. CONTRACTOWASTE MANAGEMENT TERIALS. DUMPING OF EXP. DATE. �C �� �� 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL ANDIOR FINAL UNUSED ORWASTEPRODUCTS SHALL BE SON THIBLE E GROUND, WHERE WATER CAN CARRYY DISPOSING OF ALL WASTE THEMINTO THE CONVEYANCEND UNUSED CONSTRUCTION SYSTEMIS STRICTLY ��� F�UtO� <Q �2 � O V\I,��F 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE JOB #: 18-7045 U 02 RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT LDEV-013765-2020 CITY PROHIBITED. 0 �Exp. -z U J Exp. 7, HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS W = 12/31 /2023 0 W U 12/31 /2023 U m AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN C.W. LA MONTE COMPANY, INC. U U 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE 7840 EL CAJON BLVD, SUITE200, LA MESA CA 91942 U No. 25241 No. 495 GRADING OPERATION. REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH12. F TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. PH: (619) 462-9861 C'v TEST ALL GRADING SHALL BE INSPECTED AND TESTED BY QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR T� �F\� �T� \� REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE ALLOW RAINWATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE STATEMENT OF ENGINEER OF WORK CA OF FF\ SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT TOLL FREEAT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. I E. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED US ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ENGINEER CONTROLS H PERFORMANCE THE ENGINEER AGREES THAT ANY PLAN HE K R REVIEW PERFORMED BY THE CITY F WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK G IN 0 S CIT 0 CE G G S C C 0 0 C 0 HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAYBE REQUIRED FOR THIS STRUCTURE. AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE CONTROL MEASURES HAVE BEEN INSTALLED. FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFYAND 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE SAN DIEGUITO WATER DISTRICT NOTES NOTIFICATIONS ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE WITHIN THE COURSE AND SCOPE OF S AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A • CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR SIGNATURE: DATE: 0512012022 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THEACCURACY STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID BRIANARDOLINO THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK OF, THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: PASCO, LARET, SUITER &ASSOCIATES AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR THE LIMITS OF THIS PROJECT. 535 N. HWY 101, SUITE A, EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SOLANA BEACH, CA 92075 SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED A. SEWERS - LEUCADIA WW DISTRICT - (760)-753-0155 D. RECYCLED WATER -SAN ELIJO JOINT POWERS AUTHORITY- (760) 753-6203 X-32 CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER B. GAS & ELECTRIC - SDGE - (760)-438-6200 E. TELEPHONE - SBC BELL - (760)-489-3411 PH: (858) 259-8212 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN C. WATER - SAN DIEGUITO WATER DISTRICT-1-760-633-2650 F. CABLE TV - COX COMMUNICATIONS-(760)-806-9809 X-2233 SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: SHEET INDEX TO THE DISPOSAL OF ANY SUCH MATERIAL. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE ANDIOR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE (760)-633-2770. 1, TITLE SHEET HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES 32. LEGEND AND DETAILS 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITYS URBAN FOREST MANAGEMENT PROGRAM. TREES MUST MEET CURRENT WATER AGENCIES . THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: 633-2770. ALL WORK PERFORMED WITHOUT STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET ( 3. GRADING PLAN LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. 4. SECTIONS AND DETAILS SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR 5. EROSION CONTROL PLAN DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE OWNER'S CERTIFICATE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE 6. MINIMUM HORIZONTAL SEPARATION OF 10-FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. DIEGO GAS AND ELECTRIC VAULTS. OVER ALL GRADING ACTIVITYAND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS. THE PROJECT CONTRACTOR SHALL DIVERT, DIRECT OR TEMPORARILY HALT GROUND -DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY WATER METERS MUST BE IN FRONT OF THE PARCEL THEYARE SERVING. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR BMP PROJECT STATUS DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. pF E S S/p ACTIVITIES ARE ALLOWED TO RESUME. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC QFZ ry9 PROTECTION INACCORDANCE WITH WC-17OR WC-18. SIGNATURE: DATE: 811212022 ��0 HAE1 q�l PRIORITY STORMWATER TREATMENT FACILITIES TO BE MAINTAINED BY IMPERVIOUS AREA EARTHWORK DATA 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE �� HOA IN ACCORDANCE WITH "MAINTENANCE AGREEMENT FOR PRIVATE �Q �� DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, 0PRINT NAME: DANIEL FRYE PARTNER STORMWATER TREATMENT AND STORMWATER POLLUTION CONTROL z z SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 35,999 SQFT STEEPEST EXISTING NATURAL SLOPE ON -SITE = 2 H : 1 V w m No. 71651 o m FACILITIES THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED IMPERVIOUS AREA AFTER CONSTRUCTION: 19,350 SQFT MAXIMUM VERTICAL DEPTH OF CUT = 3.5' DANIEL FRYE ON BEHALF OF DLS HOLDINGS LP Exp. 12/31 /23 ARCHAEOLOGIST AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THE 15% CONTINGENCY FUTURE IMPERVIOUS AREA: 2,903 SQFT MAXIMUM VERTICAL DEPTH OF FILL = 2.2' A CALIFORNIA LIMITED PARTNERSHIP RECORDED ON NOVEMBER 30, 2022 CORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097.98. IF SUCH TOTAL IMPERVIOUS AREA (FULL BUILDOUT): 22,253 SQFT CUT = 350 CY FILL = 770 CY `sT CI V 1 _ �P AS DOC. #: 2022-0453971 A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DECREASE IN IMPERVIOUS AREA: 13,746 SQFT IMPORT = 420 CY REMEDIAL = 513 CY 9TF OF CAS DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST ANDIOR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, IMPERVIOUS AREA REPLACED: 0 SQFT DISTURBED AREA = 34,125 SF THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU ('IN PLACE'), OR IN A SECURE LOCATION IN CLOSE SDWD W21-030 PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. TL� >< �� 11/30/2022 Bob Keeley �11130/2022 Steven Kelly Gaffrey 11/29/2022 December 6, 2022 SI DATE SIf N n DATE SIGN DATE SIGN DATE SIGN DATE CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: BMA I RDM BMA GINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: STATION "134WCCS1" INT. DATE PLANS PREPARED UNDER SUPERVISION OF coNDED: APPROVED: GRADING PLANS FOR: LOCATION: 2.5" BRASS DISC IN THE SOUTHEAST PUBLIC WORKS ° DATE: 8/12/2022 �i Jill T. Bankston 555 & 571 NORTH VULCAN AVENUE BRIAN ARDOLINO DATE LDEV-013765-2020 QUADRANT OF LEUCADIA BLVD. AND ORPHEUS ° ICHA TRIZIC JILL T. BANKSTON AVE. PLANNING APN: 256-090-06 & 07 �\.; R.C.E. NO.: 71651 PRINCIPAL ENGINEER CITY ENGINEER RECORD FROM: ROS 18416 PRINCIPAL ENGINEER DATE REVIEWER 12/08/2022 12/13/2022 ELEVATION: 178.543' DATUM: NAVD88 INSPECTOR I BRIAN ARDOLINO EXP.: 12/31/23 DATE DATE I PLANNING CASE NO: 18-220 TMDB/DR/CDP/EIA MULTI-002569-2018 I SHEET 1 OF 5 0 N Q U O O w_ W in N Zr U o � O 0 N U) r QwLO 06 D w U X �L� �aC-4 O N w W 00 Q<-LO � N Z OU)00 U� Qrn= r PLSA 2872 LEGEND LEUCADIA WASTEWATER DISTRICT NOTES 1. LWD APPROVAL OF THESE PLANS DOES NOT RELIEVE THE APPLICANT, -PRIVATE ENGINEER OF WORK, OR CONTRACTOR FROM RESPONSIBILITY -FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING -OR AFTER CONSTRUCTION. 2. ALL DESIGN, MATERIALS, AND CONSTRUCTION WORK SHALL CONFORM TO❑THE LEUCADIA WASTEWATER DISTRICT LWD SEWER STANDARDS AND TO -THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS FOR PUBLIC -WORKS CONSTRUCTION (GREENBOOK) AND THE REGIONAL STANDARD, DRAWINGS. MOST CURRENT EDITIONS. IN THE EVENT OF CONFLICT THE-LWD SEWER STANDARDS GOVERN. 3. OSHA SAFETY ORDERS AND OSHA CONFINED SPACE ENTRY -REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES WITHOUT EXCEPTION. 4. -'_'THE CONTRACTOR SHALL HAVE A COPY OF THE SEWER NOTES 2A 3. - DOCUMENTS ON THE JOB SITE AT ALL TIMES. 5. THE CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE-YEAR AFTER THE DATE OF FINAL ACCEPTANCE BY LWD AND SHALL -REPAIR OR REPLACE ANY WORK THAT MAY PROVE DEFECTIVE IN -WORKMANSHIP AND/OR MATERIALS WITHIN THE ONE YEAR PERIODWITHOUT EXPENSE WHATSOEVER TO LWD. 6. QUANTITIES SHOWN HEREON ARE FOR BOND ESTIMATE PURPOSES ONLY. -NEITHER THE PRIVATE ENGINEER NOR LWD GUARANTEE THE ACCURACY -OR COMPLETENESS OF THE SEWER QUANTITIES 7. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT SHOP -DRAWINGS REPRESENTING ALL MATERIALS AND SUPPLIES SATISFACTORY TO LWD. WORK SHALL NOT COMMENCE UNTIL SUCH MATERIALS ARE -APPROVED BY LWD. 8. PRIOR TO BEGINNING SEWER WORK, THE LWD INSPECTOR SHALL BE -FURNISHED A SETS OF CUT SHEETS AND THE CONTRACTOR SHALL -COMPLY WITH LWD STANDARD SPEC SURVEY REQUIREMENTS. 9. PRIOR TO START OF WORK, CONTRACTOR SHALL SECURE A LWD PERMIT -FOR CONSTRUCTION, SUBMIT SHOP DRAWINGS FOR ALL MATERIALS FOR -REVIEW & APPROVAL, SCHEDULE AND ATTEND A PRECONSTRUCTION- MEETING PER APPENDIX V OF STD SPEC, PROVIDE 3-WEEK LOOK AHEADSCHEDULE(S) FOR ALL SEWER WORK THRU-OUT PROJECT IN ADDITION - TO 72 HOURS NOTICE OF NEED FOR EACH INSPECTION. 10. NO WORK SHALL BE COMMENCED UNTIL ALL RIGHT-OF-WAYAND-OTHER REQUIRED PERMITS HAVE BEEN OBTAINED FROM THE -JURISDICTIONAL CITY, COUNTY, AND/OR OTHER APPROPRIATEL-AGENCIES. 11. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 67057BY SUBMITTING A DETAIL PLAN TO THE DISTRICT ENGINEERLSHOWING THE DESIGN OF SHORING, BRACING, SLOPING, OR OTHER -PROVISIONS TO BE MADE FOR PROTECTION OF WORKERS FROM THE -HAZARD OF CAVING GROUND DURING TRENCH EXCAVATION ANDLPIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FORLALL TRENCHES FIVE FEET OR MORE IN DEPTH. IF THE PLAN VARIES -FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE -CONSTRUCTION SAFETY ORDERS, TITLE 8, CALIFORNIA-ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BYA REGISTERED ENGINEER. A COPY OF THE OSHA EXCAVATION PERMIT=MUST BE SUBMITTED TO THE LWD INSPECTOR PRIOR TOLEXCAVATION. 12. ALL SEWER FACILITIES SHALL BE INSTALLED IN DRY EXCAVATIONS AND -TRENCHES. CONTRACTOR SHALL DEWATER AND MAINTAIN DEWATERING-CONTINUOUSLY UNTIL THE WORK IS COMPLETED INCLUDING PLACEMENT -AND COMPACTION OF BACKFILL MATERIALS IN A DRY STATE. ALL PIPE -ZONE MATERIAL LOCATED IN WET OR AREAS SUSPECTED TO BE WET IN -THE FUTURE SHALL BE ENCASED IN GEOTEXTILE MATERIAL. SUITABLE-GEOTEXTILE MATERIAL SHALL BE SUBMITTED TO THE DISTRICT ENGINEERLFOR REVIEW AND APPROVAL. CONTRACTOR SHALL OBTAIN DEWATERING-PERMITS AS NECESSARYAND RETURN OF GROUNDWATER TO THE -SEWER SHALL NOT BE ALLOWED. 13. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES SHOWN ON -THESE PLANS WAS OBTAINED BYAVAILABLE RECORDS SEARCH BY THE -PRIVATE ENGINEER. TO THE BEST OF THE PRIVATE ENGINEER'SLKNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN -ON THESE PLANS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE -OF OTHER UTILITIES OR STRUCTURES NOT SHOWN, OR IN A DIFFERENTLLOCATION FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR SHALL TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES -SHOWN ON THE PLANS AND OTHER EXISTING FACILITIES OR -STRUCTURES NOT SHOWN. 14. APPROVAL OF THIS PLAN BY LWD DOES NOT CONSTITUTE A.:7 REPRESENTATION OF THE ACCURACY OF THE LOCATION OF, OR THE -EXISTENCE OR NONEXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE,LOR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 15. -CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800)-422-4133, TWO BUSINESS DAYS PRIOR TO ANY EXCAVATION, AS REQUIRED BY STATE LAW. ALL UTILITY CROSSING S-SHALL BE POT HOLED PRIOR TO TRENCHING. 16. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL LOCAL, STATE, -AND FEDERAL SAFETY REGULATIONS INCLUDING, BUT NOT LIMITED TO, -TRENCH SAFETY AND CONFINED SPACE ENTRY. 17. SOILS REPORTS SHALL BE SUBMITTED TO LWD BYA QUALIFIED SOILS -ENGINEER WHICH CERTIFIES THAT TRENCH BACKFILL WAS COMPACTED -AS DIRECTED BY THE SOILS ENGINEER IN ACCORDANCE WITH ON SITE -EARTHWORK SPECIFICATIONS AND THE LWD STANDARD SPEC. 18. SEWER ELEVATIONS SHOWN ARE INVERT ELEVATION (I.E.), INSIDE -BOTTOM OF PIPE. SEWER LENGTHS SHOWN ARE FROM CENTER OF -MANHOLE TO CENTER OF MANHOLE. 19. ALL REVISIONS TO DRAWINGS SHALL BE APPROVED BY THE LWD_-DISTRICT ENGINEER AS CONSTRUCTION CHANGES TO THE ORIGINAL MYLAR DWGS. WITH INITIALED APPROVAL ON THE MYLARS. 20. CONTRACTOR IS RESPONSIBLE FOR KEEPING COMPLETE RECORD OFLCHANGES AND SHALL MAKE SUCH RECORD AVAILABLE TO THE PRIVATELENGINEER. THE PRIVATE ENGINEER SHALL PROVIDE AS -BUILT DRAWINGS -TO LWD FOR REVIEW AND APPROVAL PRIOR TO FINAL ACCEPTANCE OF -THE PROJECT. 21. LENGTH OF OPEN TRENCH SHALL BE LIMITED TO 350 FEET, INCLUDING -COLLECTORS AND LATERALS, UNLESS OTHERWISE APPROVED IN WRITING -BY THE DISTRICT. TRENCH SHALL BE BACKFILLED OR PLATED AT THE -CONCLUSION OF EACH DAY OF WORK. 22. THE CONTRACTOR SHALL PROTECT ALL SURVEY MONUMENTATION. IF -ANY SURVEY MONUMENTS ARE DISTURBED OR DESTROYED, THE -CONTRACTOR SHALL RETAIN A LICENSED SURVEYOR TO REESTABLISH -AND RECORD THE MONUMENT CHANGE PER STATE LAW. 23. A MINIMUM OF 12-INCHES OF VERTICAL CLEARANCE SHALL BE PROVIED -BETWEEN THE SEWER PIPE AND ANY OTHER UTILITIES. EXIST. SEWER -CROSSED WITHIN 3-FT VERTICAL ABOVE OR BELOW SHALL BE CCTV- INSPECTED BOTH BEFORE AND AFTER THE CROSSING WORK IS -COMPLETED FOR LWD REVIEW, APPROVAL, & RETENTION OF DIGITAL-- VIDEO FILES. ANY DAMAGED LWD FACILITIES SHALL BE REPAIRED TO-LWD SATISFACTION AT NO COST TO LWD INCLUDING ADDITIONAL CCTVANSPECTION. 24. SEPARATION OF SEWER / WATER AND SEWER / RECLAIMED WATER=SHALL COMPLY WITH LWD STD DWG S-2 AND WITH ALL COUNTY AND -STATE HEALTH DEPT REGULATIONS. 25. CONNECTIONS TO EXISTING SEWER PIPE OR MANHOLES SHALL ONLY BE -DONE IN THE DIRECT PRESENCE OF THE LWD INSPECTOR. NEW SEWER -SHALL NOT BE CONNECTED OR ALLOWED TO FLOW TO EXISTING SEWER -UNTIL AFTER FINAL ACCEPTANCE OF ALL UPSTREAM WORK BY THE LWD 7 INSPECTOR, OR AS APPROVED BY DISTRICT ENGINEER. 26. ALL SERVICE LATERALS SHALL BE LOCATED AT RIGHT ANGLES TO THE -SEWER MAIN UNLESS OTHERWISE SHOWN AS APPROVED BY LWD ON -THE PLANS. 27. A 2-INCH HIGH "S" SHALL BE INSCRIBED ON THE CURB FACE AT EACH -LATERAL LOCATION BY THE CONTRACTOR. 28. ALL PIPE SHALL BE HANDLED AND INSTALLED SO AS TO PROTECT -PIPE, JOINTS, LINING, AND COATING. THE PIPE SHALL BE CAREFULLY -BEDDED TO PROVIDE CONTINUOUS BEARING AND PREVENT UNEVEN -SETTLEMENT PIPE SHALL BE PROTECTED AGAINST FLOTATION AT ALL -TIMES. OPEN ENDS OF PIPE SHALL BE SEALED AT ALL TIMES WHEN -CONSTRUCTION IS NOT IN PROGRESS. ORIFICE PLATE: MIN SQUARE _\ DIMENSIONS 1.0 FT GREATER THAN MIN, 6" PIPE DIA. HOT DIP GALVANIZED PLATE ` (TYP.) AFTER HOLES HAVE BEEN DRILLED l 1 CHANGE NO. NOTE: ORIFICE AND FLANGE CONNECTION TO CONCRETE SHALL BE FILLED WITH 30 DUROMETER NEOPRENE RING INFLOW PIPE (4" PERF. PVC TYP.) LOW -FLOW ORIFICE (SIZE PER PLAN) 3/8" DIA. HOLE (TYP.) TYPICAL DETAIL - FLOW CONTROL ORIFICE PLATE NOT TO SCALE 29. PIPE JOINTS SHALL NOT BE DEFLECTED UNLESS SO DESIGNED AND -SHALL THEN BE LIMITED TO LESS THAN ONE-HALF OF THE ANGLE -RECOMMENDED BY THE PIPE MANUFACTURER. 30. SEWER PIPE ZONE AND TRENCH BACKFILL SHALL BE PER THE LWD- SEWER STANDARDS SPECIFICATIONS. WATER JETTING SHALL NOT BEALLOWED. 31. ALL LATERALS SHALL BE CONSTRUCTED CLEAR OF DRIVEWAYS. 32. JOB MIXING OF CONCRETE IS NOT ALLOWED WITHOUT EXCEPTION. -CONCRETE TESTING BY LWD WILL BE AT CONTRACTOR EXPENSE. 33. MANHOLE BASES SHALL BE MONOLITHICALLY PLACED, FINISHED, AND -COMPLETED AT TIME OF PLACEMENT. GPK PRODUCTS, INC., OR -APPROVED EQUAL, MANHOLE ADAPTERS SHALL BE SET IN THE BASE -FOR EACH PIPE CONNECTION. SETTING OF MH RINGS SHALL NOT BE -ALLOWED FOR 48 HOURS AFTER CONCRETE PLACEMENT. PRECAST -MANHOLE BASES ARE ACCEPTABLE FOR USE WITH DISTRICT APPROVAL. 34. JOINTS BETWEEN MH BASE, SHAFTING, CONE SECTIONS, AND RING=SHALL HAVE 2" BY 2" BUTYL RUBBER GASKET PLACED WITHIN THELFULL CIRCUMFERENCE. GASKET SHALL BE CPS-210 BY PRESS-SEALLGASKET CORP., OR APPROVED EQUAL. 35. -ALL MANHOLES SHALL BE VACUUM TESTED 1) BEFORE BACKFILL, 2)-AFTER BACKFILL, AND 3) SUBSEQUENT TO ANY SUSPECTED MOVEMENTOR DAMAGE AFTER BACKFILL. 36. ALL SEWERS AND LATERALS SHALL BE WAYNE BALLED OR JETTED, LOW-PRESSURE AIR TESTED, AND TELEVISED AT THE APPLICANT -/CONTRACTORS EXPENSE PRIOR TO CONSIDERATION FOR FINAL -ACCEPTANCE BY LWD. AIR TEST SHALL BE DONE AFTER CONSTRUCTION OF ALL OTHER UTILITIES AND UTILITY LATERALS. 37. ALL SEWERS AND LATERALS SHALL BE IN PLACE AND SHALL HAVE -FINAL APPROVAL BY THE LWD INSPECTOR PRIOR TO BACKFILL. 38. MANHOLES SHALL BE 4-FEET DIAMETER FOR PIPE UP TO 15-INCH` DIAMETER PER LWD STD DWG S-3. MANHOLES SHALL BE 5-FEETLDIAMETER FOR PIPE 18-INCHES AND LARGER OR 12-FEET OR GREATER -DEPTH PER LWD STD DWG S-4. 39. ALL NEW MH SHAFTS AND PRECAST MH BASES SHALL BE LINED WITH` APPROVED LININGS SPECIFIED IN DIVISION 2 PART 5 TABLE 502-1.1 OF THE LWD SEWER SPECS. EPDXY OR PVC LINING SYSTEMS SHALL BE PER SECT 500-2 OF THE GREENBOOK. A MINIMUM OF FIFTEEN PERCENT (15%) OF MANHOLES AND NOT LESS THAN ONE PERCENT -(1 %) WITH EPDXY LINERS SHALL SUCCESSFULLY PASS PULL -TEST AND, BE REPAIRED UNTIL PASSING. 40. MAXIMUM DEPTH OF SEWER FOR SDR 35 PVC PIPE IS 15'. C900 PIPE AS REQUIRED FOR DEPTH OF COVER OVER 15'. 41. FINAL APPROVAL OF PLANS BY DISTRICT ENGINEER IS VALID FOR A -PERIOD OF TIME NOT TO EXCEED ONE YEAR FROM APPROVAL DATE TO -START OF CONSTRUCTION. IF THE ONE YEAR TIME LIMIT IS EXPIRED -PRIOR TO START OF CONSTRUCTION THE DEVELOPER SHALL RESUBMIT -THE PLAN CHECK TO THE DISTRICT ENGINEER FOR AN UPDATED REVIEW -AND APPROVAL. ANY CHANGES REQUIRED TO THE PLANS SHALL BE -MADE AT THE DEVELOPERS EXPENSE AND APPROVED BY THE LWD--DISTRICT ENGINEER PRIOR TO THE START OF CONSTRUCTION. 42. WHEN CONNECTION TO AN EXISTING MANHOLE IS NECESSARY AND SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL CONNECT TO -EXISTING MANHOLE STRUCTURES AND CONSTRUCT THE NEW -FLOW -THROUGH CHANNELS IN EACH MANHOLE BASE TO ACCOMMODATE -THE NEW SEWER LINES AS REQUIRED. SMOOTH TRANSITIONS SHALL BE -INSTALLED FROM THE INVERTS OF NEWLY INSTALLED PIPES TO THE -EXISTING MANHOLE STRUCTURES. MANHOLES SHALL BE CORE DRILLED -AND MANHOLE CONNECTION FITTINGS SHALL BE CONNECTED TO THE -CORE DRILLED HOLE BY LINK -SEAL, OR APPROVED EQUAL. THE FIRSTLFLEXIBLE JOINT SHALL BE LOCATED WITHIN ONE -FOOT OF THE MANHOLE BASE. JACK HAMMERING SHALL NOT BE ALLOWED. 43. ALL NEW CONNECTIONS TO EXISTING SEWER SHALL BE MADE TOLEXISTING WYES OR SHALL BE MADE BY INSTALLING NEW -MANUFACTURED WYES. FOR INSTALLING NEW MANUFACTURED WYES,SSTANDARD BELL AND SPIGOT OR PLAIN END WYES AND PLAIN END -PIPE SPOOLS MATCHING THE ADJACENT EXISTING PIPE MAY BE USED -FOR INSERTING WYES INTO AN EXISTING SEWER. GASKETED PVC SADDLE-WYES MAY BE USED FOR EXISTING SEWER MAINS 10-INCHES AND -LARGER. ALL CONNECTIONS NOT MADE TO EXISTING WYES MUST BE IN -ACCORDANCE WITH LWD STANDARD DRAWING S-32. 44. IF NECESSARY DURING THE LATERAL CONNECTION WORK, UPSTREAM -FLOW IN THE EXISTING SEWER SHALL BE TEMPORARILY PLUGGED ANDLBY-PASSED. A BY-PASS PLAN IN ACCORDANCE WITH LWD STANDARD -DRAWING S-32 MUST BE REVIEWED AND APPROVED BY THE LWDDISTRICT ENGINEER PRIOR TO INSTALLING THE TEMPORARY PLUG. 45. FOR CONNECTION OF PLAIN END TO PLAIN END PVC SEWER, REPAIRLCOUPLINGS SHALL BE MADE OF PVC MATERIAL MEETING THE SAME -MATERIAL REQUIREMENTS AS THE PIPE BEING REPAIRED. PVC SEWERSREPAIR COUPLINGS SHALL BE RUBBER GASKETED WITH NO CENTER -STOP. PIPE ENDS SHALL BE THOROUGHLY CLEANED PRIOR TO -INSTALLATION OF THE REPAIR COUPLING(S). THE REPAIR COUPLING_ SHALL BE SLIPPED ALL THE WAY ON TO ONE PLAIN END PIPE, THEN THE PIPE AND ADJOINING PIPES SHALL BE ALIGNED TOGETHER AND - THE REPAIR COUPLING SLIPPED BACK INTO A POSITION EQUALLY SPACED BETWEEN THE TWO PLAIN END PIPES. PVC SEWER REPAIR -COUPLINGS SHALL BE AS MANUFACTURED BY PW PIPE OR EQUAL -APPROVED BY THE LWD DISTRICT ENGINEER. 46. PVC OR VITRIFIED CLAY PIPE (VCP) SEWER PIPE AND WYES MAYBE -USED TO TIE-IN TO EXISTING VCP. FOR CONNECTION OR REPAIR OF -PLAIN END VCP TO VCP OR VCP TO PVC A FERNCO SERIES 5000 -COUPLING OR APPROVED EQUAL SHALL BE USED-L-. THE CONNECTION SHALL BE CONCRETE ENCASED A MINIMUM 12" ON EACH SIDE OF THE COUPLING. 47. FOR CONNECTION OF NEW LATERALS TO EXISTING PIPE GREATER THAN-8-INCH DIAMETER CONTRACTOR SHALL CUT IN A NEW WYE PER ABOVE- OR MAY USE A SUITABLY SIZED SEWER SADDLE WYE PER STD. DWG.-S-32. 48. CONTRACTOR SHALL BE AWARE THAT LWD FACILITIES PROVIDE -WASTEWATER CONVEYANCE, TREATMENT, AND DISPOSAL TO THE PUBLIC-24 HOURS A DAY, 365 DAYS A YEAR. THEREFORE, LWD OR THEIRnCONTRACTORS MAY NEED ACCESS TO FACILITIES FOR OPERATIONS, -MAINTENANCE, OR EMERGENCY REPAIR AT ANY TIME. THE CONTRACTOR- WILL ENSURE THAT ACCESS TO THE FACILITIES IS MAINTAINED AT ALL -TIMES (DURING CONSTRUCTION AND AT THE END OF EACH -CONSTRUCTION DAY) AND SHALL NOT HINDER AND WOULD BE EXPECTED TO ASSIST WITH ACCESS WHILE WORKING AROUND LWD=FACILITIES. 49. CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARYTO PROTECT LWD FACILITIES AND STRUCTURES DURING CONSTRUCTION. -SHOULD THE CONTRACTOR AT ANY TIME DAMAGE LWD OR PRIVATE -SEWER LATERAL FACILITIES, THE CONTRACTOR SHALL IMMEDIATELY -STOP WORK, NOTIFY LWD, MINIMIZE AND CONTROL ANY SEWAGE SPILL, -AND REPAIR DAMAGED FACILITIES TO THE SATISFACTION OF THE LWD-ENGINEER AT NO COST TO LWD INCLUDING INSPECTION AND ANY --BYPASSING REQUIRED. DAMAGE CAUSED TO SEWER FACILITIES SHALL -BE REPAIRED IN ACCORDANCE WITH ALL APPLICABLE LWD STANDARD -SPECIFICATIONS AND DRAWINGS. SUBMIT FOR LWD APPROVAL PRIOR - TO REPAIR. 50. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PREVENTING -SEWAGE SPILLS; CONTAINING ANY SEWAGE SPILLS; RECOVERY AND -LEGAL DISPOSAL OF ANY SPILLED SEWAGE ARISING FROM ANY WORK -ADJACENT TO LWD FACILITIES OR ALLOWING A SEWAGE SPILL OR -FAILURE TO PREVENT A SEWAGE SPILL WHILE PERFORMING THE WORK. -CONTRACTOR WILL BE RESPONSIBLE FOR ALL CLEAN-UP COSTS AND -PENALTIES ASSESSED TO THE DISTRICT AS A RESULT OF A SEWAGE -SPILL CAUSED BY THE CONTRACTOR. 51. CONTRACTOR SHALL NOTIFY LWD A WEEK IN ADVANCE OF PLANNEDCONSTRUCTION ACTIVITIES IN THE AREA OF WORK POTENTIALLYAFFECTING LWD SEWER FACILITIES. 52. - -CONTRACTOR SHALL NOTIFY LWD 48 HOURS PRIOR TO EXCAVATION OF -SEWER UNDER CROSSINGS, OVERCROSSINGS, OR PARALLEL- INSTALLATIONS WHERE SEWER MAYBE EXPOSED. s s s s s s •- s 0 0 0 0 0 o STRUCTURAL SECTION; 4"AC OVER 21 " CLASS II AB MIN OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP. AC PAVEMENT SECTION NOT TO SCALE DESCRIPTION APPROVED DATE BENCHMARK DESCRIPTION: STATION "134WCCS1" LOCATION: 2.5" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS AVE. RECORD FROM: ROS 18416 ELEVATION: 178.543' DATUM: NAVD88 6" CURB TC ELEV.= 2 PER SDG-150 PAVEMENT ELEV. + 0.5' TYPICAL DETAIL - CURB TAPER NOT TO SCALE AS -BUILT APPROVALS BRIAN ARDOLINO DATE PRINCIPAL ENGINEER DATE PUBLIC WORKS PLANNING REVIEWER INSPECTOR SPECIAL INSPECTION NOTE NOTE: SPECIAL INSPECTION OF THE BMP FACILITIES BYA LICENSED CIVIL ENGINEER IN THE STATE OF CALIFORNIA IS REQUIRED DURING CONSTRUCTION. PRIOR TO OBTAINING BUILDING OCCUPANCY, AN INSPECTION REPORT SHALL BE SUBMITTED WITH THE FINAL GRADING CERTIFICATION TO THE ENGINEERING DIVISION VERIFYING THE SIZE AND DEPTH OF THE EXCAVATION, GRAVEL AND ENGINEERED SOIL DEPTH AND MATERIAL, STORM DRAIN PIPE, OVERFLOW, AND OVERALL FUNCTION OF THE FACILITIES PER THE APPROVED GRADING PLAN. THE INSPECTION REPORT SHALL INCLUDE ANY PERTINENT INFORMATION INCLUDING MATERIAL RECEIPTS, SURVEY DATA, INSPECTION DATES, ETC. IN ORDER TO DETAIL THE CONSTRUCTION OF THE DRAINAGE FACILITY. SPECIAL INSPECTION REPORT IS ON FILE WITH THE ENGINEERING DIVISION PREPARED BY DATED 2" HARDWOOD MUL CHI GRASS COVER OR CITY APPROVED EQUIVALENT TIN PER PLAN-\ 18" LAYER ENGINEERED SOIL *SEE NOTE BELOW -ill-III= 111=� 12'x 12" OVERFLOW INLET, TG PER PLAN DROUGHT TOLERANT PLANTS (TYP.) 10 PONDING -1 I I-111-111-111 2" LAYER OF 318" GRAVEL 12" LAYER OF 3/4" GRAVEL **SEE NOTE BELOW * BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 65% SAND, 15% COMPOST OR HARDWOORD MULCH, AND 20% TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. ** 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON CALCULATION. ITEM & STD. DWG. SIDS SYMBOL SUBDIVISION BOUNDARY (EXISTING) SUBDIVISION BOUNDARY (PROPOSED) PROPERTY LINE / RIGHT-OF-WAY CENTERLINE OF ROAD PROPOSED SETBACKS EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED FLOWLINE PROPOSED SWALE PROPOSED PERVIOUS PAVERS SEE DETAIL SHEET 2 PROPOSED PCC PAVEMENT PROPOSED AC PAVEMENT SEE DETAIL SHEET 2 PROPOSED 8" SEWER MAIN SEE LDEV-013766-2020 PROPOSED 4" STORM DRAIN (UNLESS OTHERWISE NOTED) PROPOSED AREA DRAIN BY NDS OR APPROVED EQUAL PROPOSED BROOKS BOX (SIZE PER PLAN) EXISTING WATER MAIN (SIZE PER PLAN) EXISTING SEWER MAIN (SIZE PER PLAN) EXISTING STORM DRAIN (SIZE PER PLAN) PROPOSED I" DOMESTIC WATER SERVICE SEE LDEV-013766-2020 PROPOSED 2" FIRE SERVICE SEE LDEV-013766-2020 PROPOSED 4" SEWER LATERAL SEE LDEV-013766-2020 PROPOSED MASONRY RETAINING WALL C-01, C-03, C-09 PRIVATE STREET LIGHT "NO PARKING FIRE LANE" SIGN 47 S S W W F F S S WEST SIDE HMP BIOFIL TRA TION BASINS HOLD HARMLESS FOR DRAINAGE AGREEMENT NOT TO SCALE ABBREVIATION LEGEND RECORDED 2022, AS DOCUMENT No.: 2022- OF 0.R. PERVIOUS PAVERS W/ BIN = BOTTOM OF WALL ELEVATION VOID FILLER-8 " TO s " (NO.8) MIN. s " VOID FS = FINISHED SURFACE ENCROACHMENT MAINTENANCE AND REMOVAL AGGREGATE IN VOIDS 6" X 16" PCC FLUSH CURB OR FG = FINISHED GRADE AGREEMENT RECORDED 2022, DEEPENED G-1 CURB FL = FLOWLINE AS DOCUMENT No.: 2022- OF O.R. BEDDING COURSE-2" THICK OF FF = FINISHED FLOOR ELEVATION 8 " TO a " (N0.8) AGGREGATE GF = GARAGE FACE ELEVATION IE = INVERT ELEVATION CHOKER COURSE-4" THICK OF " ! " �� ' �I=III=III- = = L TC = LEFT TOP OF CURB TIN = TOP OF WALL AT s TO (NO.57) CRUSHED T ° "I -III -III= MH = SEWER MANHOLE FINISHED SURFACE ROCK MIN. 6" THICK OF ! " I=III=III= RTC =RIGHT TOP OF CURB _ _ _ _ =-!-T 4 =III-III=III=III=III=III�III-III=III-1 TG = TOP OF GRATE ELEVATION CRUSHED ROCK -III=III=III=1 I I=� i i=1 I I =III=III=III= - TF = TOP OF FOOTING ELEVATION _ I- I _ SOIL SUBGRADE 1=1 1=i '- " -� �= TW = TOP OF WALL ELEVATION - -I I PED = PEDESTRIAN BIN = BOTTOM OF WALL -_- NOTE: DED = DEDICATION AT FINISHED GRADE -PAVERS SHALL BE H-20 RATED -ALL AGGREGATE MUST BE CLEANIWASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED - -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED - - -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL - SUBDRAIN MAYBE REQUIRED **CONSTRUCTION NOTE: TYPICAL DETAIL - RETAINING WALL -PAVERS TO BE COVERED AND PROTECTED DURING CONSTRUCTION NOT TO SCALE TYPICAL SECTION - PERVIOUS PAVERS NOT TO SCALE EXIST EXIST PROP. R R.O.W. R.O.W. 55' 20' 20' EX. 40.0' COUNTY ROAD EASEMENT 15 DED. 3' 2' PUBLIC PED. 5' 34.0' g 5' PERVIOUS SWALK IDE- FC TO FC SIDE- I ACCESS EASEMENT AT DRIVEWAYS PER PM I I PAVERS WALK 2" GRIND AND OVERLAY 2.0% 2.0% 2.0 0 2' 2,0% -� 2:1 MAX TO PAD 4.5' PCC SIDEWALK PERSDRSD G-7 INSTALL 6" PCC CURB \\ �����j� \\ INSTALL 6 PCC CURB TC ELEV.= PER SDRSD G-1 PAVEMENT ELEV. &GUTTER PER SDRSD G-2 � � \��j q �� \ PERVIOUS PAVERS PER ENGINEERING OVER 4 MIN CLASS II BASE \ \ �� EXIST 6" SPECIAL CONDITION 1A, AND GREEN SITE NOTES 1. EXISTING SURVEY MONUMENTS TO BE PROTECTED IN PLACE. IF MONUMENT IS DISTURBED OR DESTROYED, IT SHALL BE REPLACED BYA LICENSED LAND SURVEYOR AND A CORNER RECORD OF SURVEY SHALL BE FILED WITH THE COUNTY. 2. NO GRADING SHALL OCCUR OUTSIDE THE LIMITS OF THE APPROVED GRADING PLAN UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED FROM THE CITYAND THE OWNERS OFAN OTHER AFFECTED PROPERTIES. 3. ALL EXISTING STRUCTURES AND WALLS WITHIN THE PROPOSED DISTURBED AREA TO BE DEMOLISHED UNLESS OTHERWISE NOTED. 4. ALL EXISTING TREES WITHIN THE PROPOSED DISTURBED AREA TO BE REMOVED UNLESS OTHERWISE NOTED. 5. ALL UTILITIES SHOWN HEREON PER BEST AVAILABLE RECORDS. CONTRACTOR SHALL VERIFY EXACT HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD OF DISCREPANCIES UPON DISCOVERY. 6. SEWER, WATER, AND IMPROVEMENTS IN PUBLIC RIGHT-OF-WAYAND EASEMENTS SHOWN HEREON FOR REFERENCE ONLY. REFER TO SEPARATE IMPROVEMENT PLAN 13671-1 FOR CONSTRUCTION (TYP.) EXIST. ASPHALT OVER BASE INSTALL 6 x16 STREET CONDITION STORM 06 OF ESS/ I WATER MAIN FLUSH CURB Q� AE ONq� EXIST. 12" PVC WATER DESIGNED BY: DRAWN BY: I CHECKED BY: BMA RDM I BMA INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: 8/12/2022 X) r\-. R.C.E. NO.: 71651 BRIAN ARDOLINO EXP.: 12/31/23 EXIST. 8" SEWER MAIN TYPICAL SECTION - VULCAN AVENUE NOT TO SCALE ENGINEERING DIVISION APPROVALS C ENDED: APPROVED: Jill T. Bankston ICHA TRIZIC JILL T. BANKSTON PRINCIPAL ENGINEER CITY ENGINEER 12/08/2022 12/13/2022 DATE DATE ��H q� �O AN`='z w m No. 71651 m PASCO LARET SUITER Exp. 12/31 /23 sT CW\_ San Diego I Encinitas I Orange County �TF OF CA\-\F Phone 858.259.82121 www.plsaengineering.com CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. LEGEND AND DETAILS FOR: 555 & 571 NORTH VULCAN AVENUE LDEV-013765-2020 APN: 260-090-06 & 07 PLANNING CASE NO: 18-220 TMDB/DR/CDP/EIA MULTI-002569-2018 SHEET 2 OF 5 0 r r N rn Q U O (D w_ W Z N Z r U o) O oLO W N r Qw� 06 D w U X �UjU_ N O CN w O 00 �wEi 0) J N zco O�00 PLSA 2872 I 1 TRANSITiGiv FROND � I 10 SINGLE STORY BUILDING I / EASEMENTS OF RECORD I CURB I I AND GUTTER TO ASPHALT I EX. FIRE HYDRANT / I 1 COUNTY OF SAN DIEGO HOLDER OF AN DIKEPEI�G-05 REMOVE POLE DECORATIVE COBBLE BUILDING GAP INACCESSIBLE / O EASEMENT FOR PUBLIC ROAD PURPOSES CAP AND TERABASERVICE EX / DECORATIVE COBBLE I / RECORDED JUNE 12, 1934 IN BOOK 295, PAGE 339 5/8"WATER SERVICE TC66.7 1 TW68.6 11 MAX HT 1.9' TW68.6 11 11 TIN 68.6 ° s TW68.6 MAX HT 1'0 9 TIN68.6 SWALE@0.5% CTIN68.0 TW70.0 10 OF OFFICIAL RECORDS. N62 0712E 40.00 BIN 66.90 BW 66.9 0 OBW 67.3 N62 07'12"E 212.05' OBIN 67.3 \JBW 67.8 BW 68.60 s 'f p TC 66.7 FG 68.5f �O TG 68.1 72 . BMPA 249 SF, FS=67.30 . IE 67.3 68 !` O LEUCADIA COUNTY WATER DISTRICT HOLDER OF ' I I FL 66.2 IE 66.5 U� _ BUILDING AN EASEMENT FOR SEWER PIPE LINE AND INCIDENTAL PURPOSES RECORDED SEPTEMBER O I E 66.3 16 $ (EG 66.6) TIN 68.6 5.0' SYSB (EG 67.1) IE 67.3 (EG 67.3) TW 68.6 (EG 68.0) lFG 68.5 (EG 68.0) TG 69.5 VI / 15, 1964 AS DOCUMENT NO 1964-167928 OF I 15' O FG 68.5 BW 67.30 FG 68.5 FG 68.5 O FG 68.5 (EG 68.3) D I CA 15' FYSB 15.0' BW 67.3 FG 68.5 IE 68.6 OFFICIAL RECORDS. FG 68.5 u EXI TING SINGLE 10.5II I � 2.0% � ' 0' 2. I r====---_____� ST RYBUILDING FS 8.5 15'RYSB 11.4' EASEMENTS - PROPOSED FG 68.5 II II TO BE SINGLE STORY BUILDING � I 1 II TEMPORARY II UNIT 1 DEMOLISHED TG 68.5 O UNIT 2 1 UNIT 3 ❑ CONSTRUCTION I MAIN FF= 69.17 IE 67.4 MAIN FF= 69.17 O7 5 MAIN FF= 69.17 INDICATES EASEMENT FOR PUBLIC STREET RIGHT I I i II TRAILER MAIN PAD = 68.50 MAIN PAD = 68.50 MAIN PAD = 68.50 SWALE @ 0.5% I OF WAY OVER VULCAN AVENUE TO THE CITY OF ENCINITAS DEDICATED HEREON. _ I RET WALL PER 2 INDICATES PUBLIC PEDESTRIAN ACCESS s II II FG68.5 7 ❑ S I I (EG 67.1) (EG 68.0) 19 jjj I (EG 68.1) I SDRSD C-1 ) PROPOSED � EASEMENT FOR VULCAN AVENUE TO THE CITY OF 1 " WATER I - I 2. 0 % EG 66.8 FG 68.5 (EG 67.3) FG 68.5 4 FG 68.5 ITC � ( ) ( IT_Fs68 \ I MAX HT 3.4 ENCINITAS DEDICATED HEREON PER FINAL MAP. SERVI E I I FG 68.5 FG 68.5 IO 1 FL 66. I I 2 TG 68.5 FS 68.9 GF wT FS 68.9 GF I a 2 .9 GF II o TG 68.5 IE 67.6r' I 1\ 2 TG 68.5 TG 68.5 I I 1\ ❑ INDICATES SEWER EASEMENT TO LEUCADIA 2 IE 67. 5 0 07 16.0' IE 8 5 5 16.0' IE 67.7 IE 67. I - 16.0' I v COUNTY WATER DISTRICT GRANTED HEREON. I I - o I AREA T BED. G. FOR ' � s • i I I FS 66.7 FS 68.5 7 QFS68.7T66.1 TG 68.5 AC�ESSFG 68.5 TG 69.566.1 I W FS 68.8 FS 68.6 W 2 IE 67.7 FS 68.7 FS 68.5 FS 68.5 tiFS 68.6-o IE 68.4 O OWNER RESPONSIBLE FOR EX PAC BELL MH TO 20 � 2' "' / I BE RELOCATED AS DRIV 111} Y I 2 11.1% 14 H2O RATED RIM REPAIR/REPLACING PAVERS NECE'SARY f -' T PERVIOUS PAVERS IF SEWER IS TO BE REPAIRED f 20'PROPOSED �I _ I FS66.7 = .0 0 - _ _ _ - 1.0% 0 0 _ 1.0°0 10% IEIN61.65 OR REPLACED. SEWER EASE. 1' I S, JS- :i S S S S S S IE OUT 61.45 EX. SEWER MAIN I I I io% 0�❑ F 7 FS 69.0 HP S 68.7 FS 69.0 HP FS 68.7� FS 68.5 7 CTG 68.4 TW 71.0 10 TO BE REMOVED �1 I ^14 4 !v IE67.8 BIN68.6O ANY AND ALL TEMPORARY CONSTRUCTION V AND CAPPED II �I I � ,�, O IE67.7 14 1E67.9 TRAILERS OR SALE OFFICES USED DURING Qv - --�- - -- - - ----- -RM 68.5 - C 66.0 W W W o- W W W TG 68.5 W THE COURSE OF DEVELOPMENT SHALL BE I I F 61 FS 68.5 F 68.8 FS 68.6 2 TG 68.5 2 FS 68.6 FS 68.7 EX. SEWER TO IE IN 61.97 D 74 REMOVED PRIOR TO THE ISSUANCE OF 10' LCWD I I FL 66.0 i IE 67.7 F 68.7 IE 67.7 FS 68.5 BE REMOVED IE OUT 61.77 SEWER EASE. -- _ ,�,_ - - CERTIFICATE OF OCCUPANCY TO THE 911511964, F/P. 3 TG 67.0 TG 68.5 0 5 0 TG .5 10' 16.0' FS 68.5 _ I I 16.0' 2 7 _ SATISFACTION OF THE DEVELOPMENT 1964-167928, O.R. I I IE 59.7 I 2 IE 67.7� 2"0% O IE 67.5 5 I SERVICES DEPARTMENT. 1 1 FS 68.9 GF � I I EX. SEWER MH ------�---- - - --- TIEACKFLOW ROPOSED------------ --- - - --- - - -------------- --- - --- - - -- - ------ - ---- ---- --- RIM71.18 ( ) 1 ( ) 62.791E OUT T I C 66.5 I(EG 66.6) T 68.5 EG 67.3 EG 68.0 1 FL 66.0 1 I FG 68.5 IE 67.6 (EG 67. 5 FG 68.5 2 (EG 68.0) O FG 1,5 FS 68.9 GF FG 68.5 O 40'COUN�fRY I W W u)(TYPICAL) FG 68.5 15.0' FS 68.9 GF FG 68.5 _19 0 I FG 68.5 _ I '25 ROAD EAS . + W W I 7 FD 3/4" IP W/ CAP LS 6800 611211934, BK.29 , I '� I 15 TG 68.5 I � J(Zl PER ROS 22208 P.339, O.R. PROPOSED I x PROD UNIT 4 IE 67.4 UNIT 6 TO BE PROTECTED IN PLACE 1" WATER I ' T- . METER MAIN FF = 69.17 I 2 UNIT 5 8,5' MAIN FF = 69.17 TG 68.5 �. CONSTRUCTION NOTES I 100 YR FLOOD 0 1-0 MA FF - 69.17 MAIN PAD = 68.50 IE 67.7 I SERVICE I i o(TYPICAL) ELEVATION=66.9' MAIN PAD = 68.50 \ MAI AD = 9i50 \ - FS 68.7 EXISTING SINGLE STORY 1% N O EXISTING SURVEY MONUMENT TO BE PROTECTED IN PLACE. T I o FG 68.5 10 YR FLOOD 110.5' \ BUILDING TO BE DEMOLISHED FG 68.5J Cl) N I 1 "RI S I ELEVATION-67.5 I \ I I CONCRETE V-DITCH O INSTALL 4 AREA DRAIN BYNDS OR APPROVED EQUAL _ WORK IN R.O.W. PER I 1 2.0% o f _ 1 EG 66. 7 TIN 68.6 FG 68.5 \ EG 67.8 G 68.5 TIN 68.6 9 (EG 68.0) TG 69. 3 INSTALL 6 X 16 PCC FLUSH CURB IMPROVEMENT PLANS I 1 T ( ) O (EG 67.0) (EG 67.2) ( ) 1 (EG 67.8) BW 67.30 FG 68.5 v IE 68.1� 0 " BW 67.3 FG 68.5 T I i 16 s FG 68.5 FG 68.5 IE 67.3 FG 68.5 FG 68.5 DECORATIVE COBBLE % TG 68.5CN I 1 TC 66.466.00 O4 INSTALL DECORATIVE PAVERS PER DETAIL SHEET 8 ' PERMIT LDEV-013766-2020', 11 FL65.9 E66.0 ..y.W"TG 8.3'• ..W.W.W...... .W.W.W.W.W..........W. W.y.W. .W.W.W.y.W.W.W.W....... W.W.W.W.W.y.W..W.W........ IE67.6 N \ <n I I 6 1, y y , D� OI ATIV� (O�BLE, *BMP B - 442 SF, FS=67.30 'DECORATIVE COBBLE y y `IE 67.3 z . . . IE 66.2 . . . . . . . . . . . IEW67.3 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . z I O5 5.5" CONCRETE OVER COMPACTED NATURAL GRADE 1 (EG 66.8) TIN 68.6 (EG 67.0) IE 67.3 (EG 67.2) (EG 68.0) FG 68.5 (EG 68.0) (EG 68.0 O FG 68.5 \ FG 68.5 I I FG 68.5 TIN 68.6 O ) �� (2 SANITARY SEWER MANHOLE, SEE IMPROVEMENT PLANS PROPOSED FG 68.5 BW 67.3 \ FG 68.5 FG 68.5 BW 67.3 PROPOSED I FIRE MAX FILL O7 INSTALL 4" PVC STORM DRAIN @ 0.5% MINIMUM SLOPE 2" FIRE I 1 BACKFLOW 15.0' 2.2' SERVICE 2.0% 1 TG 68.5 10. 6"PVC @ 0A 4_.8% OS INSTALL 6" PVC STORM DRAIN @ 1.0% MINIMUM SLOPE ti w IE 67.4 68.5 z I 1 F F F `FG 68.5 UNIT 7 FG 68.5 O UNIT 8 II UNIT 9 O9 CONSTRUCT GRAVITY RETAINING WALL PER SDRSD C-09 s I uV W W ! MAX HT 3.4' 10 z I MAIN FF = 69.17 MAIN FF = 69.17 5' MAIN FF = 69.17 TG 68.5 w MAIN PAD = 68.50 MAIN PAD = 68.50 MAIN PAD = 68.50 IE 67.8�, 10 CONSTRUCT RETAINING WALL PER SDRSD C-01 I I' Vp - CAP AND PROPOSED 1' I. 175' ABANDON EX. (EG 66.7) (EG 68.0) (EG 68.0) 11 CONSTRUCT RETAINING WALL PER SDRSD C-04 Q WATER SERVICE I I DE I ATION 518" SERVICE, EG 66.5 FG 68.5 FG 68.5 FG 68.5 FOR LANDSCAPE I TC 66.2 - _ S ( ) (EG 87.0) FG 68.5-""* 8.5� 6' SCREEN WALL PER z I FL 65.7 T FG 68.5 w LFG 68.5 w 4 FS 68.9 GF w LANDSCAPE 12 INSTALL 12x12 BROOKS BOX CATCH BASIN WITH GRATE cn 5 FS 68.9 GF o FS 68.9 GF �, o 2 ! TG 68.5 ! PROVIDE SPACE FOR 13 INSTALL SEWER CLEANOUT SEE IMPROVEMENT PLANS IE 67.7 5 16.0 IE 67.5 5 I 16.0 ��6� 16.0' DRAINAGE AT BASE O TC 66.2 s S 6 .5 FS 68.5 0 7 2 TG 68.5 TG 68.7 2 TG 68.5 FS 68.7 TG 68.7 13 TG 68.5 2 FS 68.6 TG 68.7 FS 68. _DING (EG 68.0) 14 INSTALL SEWER SERVICE, SEE IMPROVEMENT PLANS FS 68. IE 67.7 IE 67.7 0 �, 13 EG 68.0 \ I I FL 65.7 I I U W IE 67.6- -IE 64.7 FS 68.6� o W W -IE 64.7 -��/ F TG 68.5 o IE 64.7 FG 68.5) FG 68.5 TG 69.5 2 2 14 20 RA E 14 S 63.5 2 IE 67.7 IE 67.6 0 15 INSTALL 6 SHARED SEWER LATERAL, SEE IMPROVEMENT PLANS z / I ! s11 PERVIOUS PAVERS 15 14 TG 68.5 TG 68.5 10.T 2•0°o o IE 62.0 20, IE 63.3 I 15 IE 63.9 2 IE 68.0 IE 67.9 16 CONNECT TO D-25 SIDEWALK UNDERDRAIN, SEE IMPROVEMENT PLANS 6' 12.2/0 0 7- 10 0 0 1.0% �� O 1.0% 1.0%� BUILDING � s' NEW AC PVMT i I I ❑ S 1.3 0 1.0 /o S y -p PER DETAIL I I FS 66.5 FS 69.0 HP FS 68.7 FS 69.0 HP-1 FS 68.7 FS 68.5 �O I 17 UNDERGROUND ALL ELECTRIC POLES, WIRES AND TRANSFORMERS 20 (''�''''ll F`j 8.7� IE 62.1 15 IE 63.4 15 i S . / DRIVE I I I 1 14 / 14 % o IE 64.0 15 TG 68.5 13 TG 66.8 - ---I - - A O I �� I �' � '� T _ (�IE� ¢1.2 13 o FS 68.8 TG 68.7 13 FS 68.7 2 TG 68.5 2 TG 68.5 � = 14 IE 64.1 i TC 65.7 I l W W TG 68.5 VIE 64.7 W o W TG 63 5 TG 68.7 67.7 IE 67.7 FS 68.6 TG 68.713 (EG 68.0) / \ 40' I IE 67.6 IE 67.7 IE 64.7 13 FS 68.5 FS 68.5 IE 64.7 FS 68.7 FG 68.5 s i FL 65.7 FS 66.5 1 68.5 FS 68.6 SAWC UT' T ° GRIND AND I I ' TG 68.5 2 5 16.0, TG 68.5 S 16.0' 1 I� ) 16.0' �b s . I OVERLAY I I i IE 67.7 FS 68.9 GF G, FS 68.9 GF W IFS 68.9 GF o / I PR PO D I T I (EG 66.3)I (EG 67.3) I I / STRIPING TO REMAIN, 1 " W4 ER I C 66.2 I , , FG 68.5 FG 8.5 FG 68.5 REPLACE PER SATISFACTION I FL 65.7 I I _ r / FG 68.5 (EG 68.0) I (EG 68.0) SER ICE I 1 EX. 10-YR FLOOD 15.0' i EX. 100-YR FLOOD 1 FG 68.5 FG 68.5 T s ' I OF CITY ENGINEER I I ELEVATION=66.9' ' / L � ELEVATION= 67 5 19' � 1 FG 68.5 I � ' F Q T.� I � T f I W o r I I W I WPOO �/ / TG 68.5 UNIT 11 0 ' T �O [ >> IE 67.4 MAIN FF = 69.17 � v UNIT 12 TW 72.0 10 UNIT / �' 2 MAIN PAD = 68.50 - BW 68.6c FG 68.5 MAII F = 69.17 8.5 MAIN FF = 69.17 MA11V PAD = 68.50 EXISTING SINGLE MAIN PAD = 68.50 SWALE @ 0.5% j J STORYBUILDING FS 68.7 2.0% "1DECORATIVE RIPRAP MAX CUT I 1 �2.0%_ EXISTING MOD AR 1 I ° MAX FILL TIN 68.6 BUILDING F(EG 67.5) o (EG 67.8) TW 68.6 BUILDING TO BE REMOVED (EG 68.0) (EG 68.0) (EG 68.0) 3.5'�' 1 2 2' (EG 66.3) BW 67.3 a TO BE REMOVED FG 68.5 FG 68.5 CBW 676(.3 FG 68.5 IFG 68.5 FG 68.5 FG 68.5 �oI I FG 68.5 IIE 67.3 IE 67.3 TG 69.5 2 1 TC 66.3 I I g SWALE 0.5% IE 67.50 1 n cc o� I 1� 99 Q9 g @ PRIVATE ROAD AND DRAINAGE FACILITIES MAINTENANCE AGREEMENT RECORDED NOVEMBER 30 , 2022, AS DOCUMENT NO.. 2022- 0453965 OF O.R. _ TG 68.3 o - IE 65.9 ' 5.D' SYSB- . " � . ,BMP C 350 SF,-FS=67.30 . ..... �� Q�p - E SS/O,v T 6 9 1 T 6 s TW 68.6 N6 °07'12"E 211. TW 68.6 9 6"PVC @ 0.8% TW 69. DECORATIVE COBBLE TW 70. TW 71.5 9 BW 66.30 BW 66.60 M� CBW 67.2 REMOVIt�E POLE 6' TALL SCREEN WALL PER BW 68.00 BW 68.60 BW 68.6 1 o BW 68.6 10 BW 68.6 10 O �pHAE� q�l CC RESOLUTION NO.2020-85 x I � No. 71651 i PASCO LARET SUITER I � 10 5 0 10 20 30 o ASSOQ U AT ES GRADING, DRAINAGE & UTILITY PLAN s� CW\_ Exp. 12/31 /23 ��P San Diego I Encinitas I Orange County SCALE: 1 " = 10' qTF OF CA\_\F Phone 858.259.82121 www.plsaengineering.com CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. BMA I RDM BMA DESCRIPTION: STATION "134WCCS1" INT. DATE PLANS PREPARED UNDER SUPERVISION OF �QM ENDED: APPROVED: LOCATION: 2.5" BRASS DISC IN THE SOUTHEAST PUBLIC WORKS DATE: 8/12/2022 Jill T. Bankston 555 & 571 NORTH VULCAN AVENUE QUADRANT OF LEUCADIA BLVD. AND ORPHEUS BRIAN ARDOLINO DATE LDEV-013765-2020 MICHA STRIZIC JILL T. BANKSTON AVE. PLANNING ^ R.C.E. NO.: 71651 CITY ENGINEER APN: 260-090-06 & 07 RECORD FROM: ROS 18416 PRINCIPAL ENGINEER DATE REVIEWER / PRINCIPAL ENGINEER 12/13/2022 ELEVATION: 178.543' DATUM: NAVD88 INSPECTOR BRIAN ARDOLINO EXP.: 12/31/23 DATE DATE PLANNING CASE NO: 18-220 TMDB/DR/CDP/EIA MULTI-002569-2018 SHEET 3 OF 5 i REMOVE POLE 0 N rn Q U O CD w W N z00 U 0) 0 C N U� Q�LO 0� U X w ��LL O 04 w 0 00 O� W d) Q 0 N J z O � 00 U .� <�� P/L 15' 2' PUBLIC PE DEDICATION EASEMENT 15' FYSB - 6" CURB PER SDRSD G-1 I 0" CURB I STREET CONDITION STORM 06 SECTION A -A NOT TO SCALE i� 15' RET. WALL PFR SDRSD C-1 P, I� 15' I I RFT \A/AI I P/L RET. WALL PER SDRSD C-9 RET. WALL PER SDRSD C-4 "jq� DEEPENED FOOTING PER BUILDING PLANS P/L 5' FF=69.2 66.8 PAD=68.5 EX. 66.7 20' ACCESS ROAD RET. WALL 5 UNIT 2 PER SDRSD C-9 FF=69.2 RET. WALL EX. 68.0 PAD=68.5 EX. 68.0 20' ACCESS ROAD PER SDRSD C-4 DEEPENED FOOTING PER BUILDING PLANS RET. WA PER SDRSD C SECTION B-B NOT TO SCALE RET. WALL PER SDRSD C-9 FF=69.2 66.8 PAD=68.5 EX. 66 SECTION C-C NOT TO SCALE RET. WALL PER SDRSD C-9 UNIT 5 FF=69.2 -EX. 68.0 PAD=68.5 EX. 68.0 F F=69.2 66.8 PAD=68.5 EX.66.7 UNIT 8 FF=69.2 .68.0 PAD=68.5 EX.68. SECTION D-D NOT TO SCALE 20' ACCESS ROAD - CCESS ROAD LANDSCAPE BENCH RET. WALL PER SDRSD C-9 FF=69.2 66.8 PAD=68.5 EX. 67. LANDSCAPE BENCH RET. WALL PER SDRSD C-9 UNIT 11 FF=69.2 68.0 PAD=68.5 EX. 68. i An1ncf1An= or:!nir'u I t P/L RET. WALL PER SDRSD C-4 w/ SCREEN WALL, 6' HT. MAX X. 69.5 6" PVC FOR OFFSITE DRAINAGE DEEPENED FOOTING PER BUILDING PLANS P/L RET. WALL PER SDRSD C-4 w/ SCREEN WALL, 6' HT. MAX rl,1169.0 6" PVC FOR OFFSITE DRAINAGE DEEPENED FOOTING PER BUILDING PLANS SCREEN 4LL 72.4 6" PVC FOR OFFSITE 6'SCREEN WALL 8"x8" OPENINGS AT 10' O.C. FOR DRAINAGE . 70.9 6" PVC FOR ' OFFSITE DRAINAGE �\ ROW OF OPEN HEAD JOINTS PER SDRSD C-08 SEWER MANHOLE ;REEN .L 1" OPENINGS AT 10' . FOR DRAINAGE 31 6" PVC FOR OFFSITE DRAINAGE )W OF OPEN HEAD ANTS PER SDRSD C-08 DRAINAGE QROF ESS/ON Uj m No. 71651 PASCO LARET SUITER SECTION E-EcrlExp. 12/31 /23 NOT TO SCALE � Q��O�'�Q��� `s'lgT CW\_ ���P San Diego I Encinitas I Orange County F OF CAQ Phone 858.259.82121 www.plsaengineering.com DESIGNED BY: DRAWN BY: CHECKED BY: CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS BMA I RDM I BMA ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: STATION "134WCCS1" INT. DATE PLANS PREPARED UNDER SUPERVISION OF C ENDED: APPROVED: SECTIONS & DETAILS LOCATION: 2.5" BRASS DISC IN THE SOUTHEAST PUBLIC WORKS ° DATE: 8/12/2022 �+ Jill T. Bankston 555 & 571 NORTH VULCAN AVENUE QUADRANT OF LEUCADIA BLVD. AND ORPHEUS BRIAN ARDOLINO DATE LDEV-013765-2020 PLANNING ^ ICHA L STRIZIC JILL T. BANKSTON APN: 260-090-06 & 07 AVE. / R.C.E. NO.: 71651 PRIPAL ENGINEER CITY ENGINEER RECORD FROM: ROS 18416 PRINCIPAL ENGINEER DATE REVIEWER 12%8�2022 12/13/2022 ELEVATION. 178.543' DATUM: NAVD88 INSPECTOR BRIAN ARDOLINO EXP.: 12/31/23 DATE DATE PLANNING CASE NO: 18-220 TMDB/DR/CDP/EIA MULTI-002569-2018 SHEET 4 OF 5 0 r N Q U 0 c� w_ Cn C N w Z r U CD M O o N C/) r Q00 w Ln H 06=)S w�Q Lww �aC,4 O w�.0 �w6, Q ES LO N J Z (] co '0 U�. Ur ADJACENT PROPERTY DISTURBANCE NOTE STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPLICANT'S PROPERTY. IF ANY DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORK, A WRITTEN LETTER OF PERMISSION FROM THE ADJACENT PROPERTY OWNER MUST BE OBTAINED AND SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ADJACENT PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AND SUBMITTED TO THE CITY IS GROUNDS FOR A STOP —WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION IS OBTAINED. ADDITIONAL NOTES 1. EROSION CONTROL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, GRAVEL BAGS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE. MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS, PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE. 2. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (DCIA) SHALL BE ALLOWED. DCIA MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS, SUCH AS ROOF, ROOF DRAIN, DRIVEWAY, AND STREET. J. ALL PARCELS ARE SUBJECT TO ARCHITECTURAL DESIGN GUIDELINES FOR FUTURE SINGLE—FAMILY RESIDENTIAL DEVELOPMENT. THESE GUIDELINES ARE AVAILABLE AT CITY HALL (505 S. VULCAN AVE, ENCINITAS, CA 92024) AND ARE APPROVED AS PER PC RES. 2006-27. LANDSCAPE EFFICIENCY BMP NOTES: 1. ROUTINE INSPECTION TO GUARD AGAINST RUNOFF AND EROSION AND TO DETECT PLANT OR IRRIGATION SYSTEM FAILURE 2. REPLACEMENT OF DEAD DYING AND DISEASED VEGETATION J. ERADICATION OF INVASIVE SPECIES 4. REPAIRING THE IRRIGATION SYSTEM AND ITS COMPONENTS WHEN REQUIRED 5. REPLENISHING MULCH AS NEEDED 6. SOIL AMENDMENT WHEN NECESSARY TO SUPPORT AND MAINTAIN HEALTHY PLANT GROWTH 7. FERTILIZING, PRUNING AND WEEDING AND MAINTAINING TURF AREAS 8. MAINTENANCE TO AVOID OBSTRUCTION OF MOTORISTS VIEWS 9. OWNER WILL BE RESPONSIBLE FOR MAINTENANCE 10. USE OF A TIMING DEVISE TO RUN ALL IRRIGATION (W/BATTERY BACKUP) 11. MAINTAIN THE SYSTEM CONSISTENT WITH MAWA (MAX APPLIED WATER ALLOWANCE) 12. REPLACEMENT OF VEGETATION TO BE CONSISTENT WITH PLANTS "HYDROZONE" 13. MAINTAIN THE IRRIGATION SYSTEM TO NOT EXCEED MAWA (MAX APPLIED WATER ALLOWANCE) NOTE: BIORETENTION BASINS SHALL BE EXCAVATED AND USED AS DESILTING BASINS DURING CONSTRUCTION. THE SILT SHALL BE COMPLETELY REMOVED AND THE BIORETENTION BASINS COMPLETED ONCE FINAL SITE STABILIZATION IS ACHIEVED, PRIOR TO OCCUPANCY AND/OR FINAL. �� 4 WDID # PLAN VIEW - EROSION CONTROL PLAN 3" TO 6" COARSE AGGREGI EXISTING GROUND 16'MIN. I I ­ v 1­1 1 11-1 BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT -OF- WAY *LESSER DISTANCE ALLOWED WITH CITY INSPECTOR APPROVAL DETAIL A: CONSTRUCTION ENTRANCE NOT TO SCALE SCALE: 1 " = 20' RUNOFF GAP BETV ACTS AS bt'ILLVVAY LAYERS OF GRAVEL BAGS WITH ENDS n] /rMl n MMrM AREA Dh DETAIL B: GRAVEL BAGS NOT TO SCALE 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON—COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY —APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. 1. SET POSTS AND EXCAVATE A 4 BY 4 IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS. 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. rr I I rr I �I EROSION CONTROL LEGEND PROPOSED CONSTRUCTION TR-1 ENTRANCE PER DETAIL A GRAVEL BAGS PER DETAIL B SE-4, SE-6, SE-10 SILT FENCE PER DETAIL C FIBER ROLL LIMIT OF WORK 2. STAPLE WIRE FENCING TO THE POSTS. 4 IN (10 CM) 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. q FILTER FABRIC WIRE DETAIL C: SILT FENCE NOT TO SCALE SE-1 SE-5 OOOO 845 EA 775 LF Ff2 240 LF GRAPHIC SCALE 1"=20' 20 0 20 40 60 Q?'OF ESS/ON HAEL q�l C/) m No. 71651 2 PASCO LARET SUITER Exp. 12/31 /23 ASSOMATES 0-1 clvi� \P San Diego I Encinitas I Orange County F of CA��F° Phone 858.259.82121 www.plsaengineering.com CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: BMA I RDM I BMA ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: STATION "134WCCS1" INT. DATE PLANS PREPARED UNDER SUPERVISION OF M ENDED: APPROVED: LOCATION: 2.5" BRASS DISC IN THE SOUTHEAST PUBLIC WORKS DATE: 8/12/2022 Jill T. Bankston 555 & 571 NORTH VULCAN AVENUE QUADRANT OF LEUCADIA BLVD. AND ORPHEUS BRIAN ARDOLINO DATEMLDEV-013765-2020 ^ MICHA STRIZIC JILL T. BANKSTON AVE. PLANNING / `j R.C.E. NO.: 71651 CITY ENGINEER APN: 260-090-06 & 07 RECORD FROM: ROS 18416 PRINCIPAL ENGINEER DATE REVIEWER/1—) PRINCIPAL 210022 ENGINEER ENGINEER 12/13/2022 ELEVATION. 178.543' DATUM: NAVD88 INSPECTOR BRIAN ARDOLINO EXP.: 12/31/23 DATE DATE PLANNING CASE NO: 18-220 TMDB/DR/CDP/EIA MULTI-002569-2018 SHEET 5 OF 5 0 N Q U O w C0LU N Q00 U U O5LO N U)� Qw00 06::)S w�Q U_ Q N ON w O 00 LU w a) Q N Z-� OU)00U