Loading...
2021-17211 G (Plans):IIt] :Iwe] mTff.AVMzto] Ii OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED GEOTECHNICAL INVESTIGATION FOR NEW, TWO-STORY RESIDENCE WITH BASEMENT GARAGE PREPARED BY EAST COUNTY SOIL CONSULTATION & ENGINEERING, INC. DATED 02-08-2021 PROJECT # 21-1147A3 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1 /2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT LDEV-017211-2021 HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT, DIRECT TO TEMPORARILY HALT GROUND - DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES ■ CHANGE NO. DESCRIPTION APPROVED I DATE BENCHMARK DESCRIPTION: LOCATION: IN DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICA COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIVITIES ARE ALLOWED TO RESUME. 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED ARCHAEOLOGIST AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THE CORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097.98. IF SUCH A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND/OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU(`IN PLACE"), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - LWD 760-753-0156 B. GAS & ELECTRIC - SDGE - (760)-438-6200 C. WATER - S.D.W.D. - 1-800-227-2600 D. TELEPHONE - SBC BELL - (760)-489-3411 E. CABLE TV - COX COMMUNICATIONS - (760)-806-9809 X-2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)-633-2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)- 633-2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. SOILS ENGINEER'S CERTIFICATE I, MAMADOU S. DIALLO A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 02-08-21 AND FOR AN UPDATE ON 07-21-99 ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN/ THE GRADING PLANS AND SPECIFICATIONS. SIGNED: GE NO.: 2704 EXP. DATE: 12/31 /23 Q 'OfESSi01V o � JOB #: 21-1147A3 ��oo� S. o,OF� COMPANY: EAST COUNTY SOIL CONSULTATION & ENGINEERING. INC. GE 2704 ,m ADDRESS: 10925 HARTLEY ROAD, SUITE "I" Exp.12-31-23 SANTEE, CA 92071 O cF PHONE: 619-258-7901 rTgT FCHN ��\P f OF GA`\Fo STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT A AR GG OUT OF THE WORK PERFORMED BY THE ENGINEER. SIGNATURE: DOUGLAS E. LOGAN COMPANY: RANCHO COASTAL ENGINEERING & SURVEYING INC. ADDRESS: 310 VIA VERA CRUZ, #205 PHONE NUMBER: 760-510-3152 RCE EXPIRES: 12 31 /2023 RECORD FROM: CITY OF ENCINITAS SURVEY CONTROL NETWORK ELEVATION: 60.601' DATUM: NAVD88 QRpF E SS O q JG�PS E • z OC a 9� U m C 39726 �r �r qTF OF CA0F DATE: 8/29/2022 LEUCADIA WASTEWATER DISTRICT SAN DIEGUITO WATER DISTRICT NOTES • SEE SHEET 5 LEUCADIA WASTEWATER DISTRICT NOTES • SEE SHEET 5 STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES • SEE SHEET 5 STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP f IMP NOTES • SEE SHEET 5 EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT TIM PARILLO AT 415-238-6961 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. NOT -A -PART APN: 254-221-02 U S74° 16' 30"W 120.00' 0 z NOT -A -PART 0 Z `O �I PROPOSED - DRIVEWAY PROPOSED RESIDENCE C Z R1 N PROJECT SITE APN: 254-221-03 < �n Z S74° 16' 30"W 120.00' NOT -A -PART APN: 254-221-04 KEY MAP SCALE: 1 " = 30' LEGAL DESCRIPTION: THE LAND REFERRED TO HEREIN IS SITUATED IN THE STATE OF CALIFORNIA, COUNTY OF SAN DIEGO, CITY OF ENCINITAS AND DESCRIBED AS FOLLOWS: LOT 13, BLOCK 3, SOUTH COAST PARK NO. 4, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA ACCORDING TO MAP THEREOF NO. 2049 FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY JULY 26, 1927. OWNER'S CERTIFICATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. l' `O APN: 254-221-38 N rn NOT -A -PART o APN: 254-221-37 0 N N 30 15 0 30 60 SCALE IN FEET SCALE: 1 " = 30' WORK TO BE DONE THE IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE ACCORDING TO THE SPECIAL PROVISIONS, AND THE FOLLOWING SPECIFICATIONS OF THESE PLANS AND STANDARD DRAWINGS: STANDARD SPECIFICATIONS 1. "GREENBOOK" STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION (2021 EDITION). 2. CALIFORNIA DEPARTMENT OF TRANSPORTATION, "MANUAL OF TRAFFIC CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES," (2009 EDITION). 3. STATE OF CALIFORNIA STANDARD SPECIFICATION S-DECEMBER 2018. STANDARD DRAWINGS 1. COUNTY OF SAN DIEGO REGIONAL STANDARD DRAWINGS-DECEMBER 2018. 2. STATE OF CALIFORNIA STANDARD PLANS -MAY 2018. DESCRIPTION STD DWG SYMBOL EXIST. LOT BOUNDARY ...................... - - EXIST. EDGE OF PAVEMENT ................ ' EXIST. CONTOURS ........................... - 85 EXIST. FENCE .................................. E] EXIST. RETAINING WALL ..................... PROP. CONTOUR .............................. PROP. P.C.C. DRIVEWAY ..................... PROP. PRO SERIES CHANNEL DRAIN...... PROP. STEM/RETAINING WALL ............. PROP. CONC. BLOCK RETAINING WALL.... PROP. 4" PVC DRAIN PIPE ................. PROP. 4" PERFORATED PIPE ............... PROP. 2" PVC SCH. 80 PRESSURE LINE. PROP. AREA DRAIN ........................... PROP. 6" MINUS ROCK ...................... PROP. BIO-RETENTION BASIN .............. PROP. BROOKS BOX .......................... PROP. SUMP PUMP ........................... P.C.C. RIBBON GUTTER ...................... EARTHWORK STEEPEST EXISTING NATURAL SLOPE ON -SITE = 10 H: 1 V MAXIMUM VERTICAL DEPTH OF CUT = 3-FEET MAXIMUM VERTICAL DEPTH OF FILL = 3.98-FEET CUT = 690 C.Y. FILL = 30 C.Y. EXPORT = 660 C.Y REMEDIAL = 200 C.Y. IMPERVIOUS AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 4,486 SQFT IMPERVIOUS AREA AFTER CONSTRUCTION: 3,518 SQFT INCREASE IN IMPERVIOUS AREA: a SQFT IMPERVIOUS AREA REPLACED: 0 SQFT SIGNATURE: DATE: 8/29/2022 TIM PARILLO PUBLIC SEWER SYSTEM APPROVAL APPROVED BY: LWD DISTRICT ENGINEER PUBLIC WORKS PLANNING DIVISION Engineering on Behalf of Public Works OWNER & PERMITTEE: OWNER: TIM PARILLO 126 7th STREET DEL MAR, CA 92014 415-238-6961 (C) SITE LOCATION: APN: 254-221-03 1439 NEPTUNE AVENUE ENCINITAS, CA 92024 PARKS AND RECREATION C33692 8/31/2022 9/8/2022 DEXTER S. WILSON, PE RCE DATE 9/14/2022 Jam` DEXTER WILSON ENGINEERING, INC. 6/30/2024 I FIRM AS -BUILT APPROVALS DOUGLAS E. LOGAN DATE PRINCIPAL ENGINEER DATE PUBLIC WORKS PLANNING REVIEWER EXP. DATE SIGN DATE SIGN DATE SIGN DESIGNED BY: DRAWN BY: CHECKED BY: AJL AJL DEL ENGINEERING DIVISION APPROVALS INT. DATE P NS PR ARED UNDER SUPERVISION OF RCM E D APPROVED: DATE: 8/29/2022 39726 MICHAEL TRIZIC JILL T. BANKSTON R.C.E. N0. PRINCIPAL ENGINEER CITY ENGINEER ENGINEER 09/22/2022 09/27/2022 DOUGLAS E. LOGAN EXP. 12-31-23 DATE DATE JUPITER SIT[ SHEET INDEX LA COST 0 -A C,_o Z vL DIANA ST- JASPER ST ■■■■■■■■■■■■■■■■■■■■■■■■■■ 5 N JASON ST HOEBE ST VICINITY MAP W GLAUCUS ST T.B. PG. 1147-A3 NO SCALE LEUCADIA BLVD `\ c LEUCADIA BLVD c RANCHO COASTAL ENGINEERING & SURVEYING SINGLE SOURCE DEVELOPMENT CONSULTANT 310 VIA VERA CRUZ, #205 SAN MARCOS, CA. 92078 (760) 510-3152 Ph / (760) 510-3153 Fax SHEET 1 COVER SHEET SHEET 2 EXISTING TOPO & DEMO PLAN SHEET 3 GRADING PLAN SHEET 4 SITE SECTIONS AND DETAILS SHEET 5 EROSION CONTROL PLAN & NOTES SAN DIEGUITO WATER DISTRICT 09-13-22 09/08/2022 DATE SIGN DATE i i c I l i BMP PROJECT STATUS i f STANDARD PROJECT c c ENCINITAS FIRE DEPARTMENT SievmXeUy Qafr'e�y 916t2022 SIGN CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT GRADING & DRAINAGE PLAN FOR: PARILLO RESIDENCE 1439 NEPTUNE AVE., ENCINITAS, CA 92024 CASE NO. CDP-004397-2021 APN: 254-221-03 1 DATE DWG. N0. l I LDEV-017211-2021 c i SHEET 1 OF 5 �12 O nv d� (n LiJ �� �( �O JJ � O -D � E� J Q nW N Ln z� 7 :c O l�- Ln j_ CD n O �z JJ JJ W ?z -D O 1J � RAProjects\7929 - Parillo\ENGINEERING PLAN S\7929-GP01.dwg 5/29/2022 2: C5 PM EXISTING LEGEND X 86.25 3� 86.29 \1 x I 86.32 I 1 I I I x I (E) WHITE EDGE I I 8817 J STRIPING ALONG NEPTUNE 86.28 1 f6.29 � 14 x 8g•�2 I � I I Q I EXISTING 4" � Q SEWER LATERAL Q I Q J 14 I I 3: 4 I I IQ 86.31 � I I I I � I APPR XIMATE 1 I 4 I I LOCATION TER MAIN I z 86.39 rn o I o o T p I RAW II o� I x rn � I 15.3' I I 86.41 I n z I rn (86.59) I I x I I I u 84.31 181 I I 86.45 I 4 Q 1 4 I EXISTING CONCRETE DRIVEWAY I� I 14 I I Q I 83.74 I TOP I ORAIN (E) 8" SEWER MAIN I I Q I I I PER LEUCADIA 85.29 gw WASTEWATER ))6.48 4 DISTRICT 92.13 92.57 \ I x APN: 254-221-02 \` x / 90.28 \ x JI \ 8g 50 � / \ 91 0, bUUINUAK T - RETAINING WALL BROCK RETAINING WALL v CONCRETE 1O WATER METER I x 93.10 x x 93.64-� - 1 S74° 16' 30"W 120.00' \ \I \ 90. I / Q r �4 J �- 9 3 (g 3.18) \ x I / I Q J i Q 4 J \ 4 4 �94. g2\ TW 93.25 Q I Q v 4 -93.23 BW 14 Q EXISTING ICONCRETE .DRIVEWAY J / I APN: 254-221-38 � Q 91.49 ti a' 4 cD J 92' 31 4 92.54 Q I J (E) GAS METER 93.55 \ 4 Q I 4 Q I z� EXISTING BUILDING N I 4 cli \ I I 1.4 I 0 EXISTING BUILDING 4 I I: 4 •• I t o 4 PATIO/DECK ABOVE GARAGE I TOP FLOOR ROOF I OUTLINE U' I (86.63)1917 �6.49 86.48 cn 86.48 X 90 6 j I 90 36.00 X86. 5 I • I a 4 / Cam. J v \ 4 (93.03) 9 �\ 4I •. I T\N 21.23 91LQ8 BW �4 400 �g24b) \ (---119 � SOS �6 9 S74° 16' 30"W 120.00' x 8 ���\\409 -��� ��� 9413 91. g X IZA N: 254-221-0 x 94.86 EASEMENT NOTE: ONLY EASEMENT ON PROPERTY IS AN EXISTING EASEMENT FOR TELEPHONE AND/OR ELECTRIC 1 94 54 APN: 254-221-37 S -9 c c \� l i c l N c 5 2.5 0 5 10 f SCALE IN FEET c SCALE: 1 " = 5' c POLES AND LINES FOR SEWER, WATER AND/OR GAS MAINS AND PIPE LINES AND RIGHTS INCIDENTAL THERETO, AS SET FORTH IN A DOCUMENT RECORDED ON JULY 6, 1944, IN BOOK 1715 PAGE 61, OF OFFICIAL RECORDS. THE EXACT LOCATION OF SAID EASEMENT CANNOT BE DETERMINED AND IS NOT PLOTTED. Q�OFESS/pN a� `� JG�Ps E. hoc �� D C 39726 sTgTF oF�cA`\FoR��P RANCHO COASTAL ENGINEERING & SURVEYING SINGLE SOURCE DEVELOPMENT CONSULTANT 310 VIA VERA CRUZ, #205 SAN MARCOS, CA. 92078 (760) 510-3152 Ph / (760) 510-3153 Fax = CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DWG. N0. AJL AJL DEL DESCRIPTION: 2.5" CITY OF ENCINITAS BRASS DISC POINT ID 1025 LOCATION:IN A WELL MONUMENT STAMPED ENC-25 LS 7322 AT THE INTERSECTION OF EL PORTAL STREET AND LA MESA AVE. RECORD FROM: CITY OF ENCINITAS SURVEY CONTROL NETWORK ELEVATION: 60.601' DATUM: NAVD88 DOUGLAS E. LOGAN DATE PRINCIPAL ENGINEER DATE INT. DATE P NS PR ARED UNDER SUPERVISION OF DATE: 8 29 2022 DATE: R.C.E. N0. 39726 ENGINEER DOUGLAS E. LOGAN EXP. 12-31-23 R COM E D MICHAEL TRIZIC PRINCIPAL ENGINEER 09/22/2022 DATE APPROVED: JILL T. BANKSTON CITY ENGINEER 09/27/2022 DATE EXISTING TOPO & DEMO PLAN FOR: PARILLO RESIDENCE 1439 NEPTUNE AVE., ENCINITAS, CA 92024 CASE N0. CDP-004397-2021 APN: 254-221-03 LDEV-017211-2021 PUBLIC WORKS PLANNING REVIEWER INSPECTOR SHEET 2 OF 5 O nv (n LJ � U -LJU O J Q nW N Ln L �r10 I �O Ln 7;;o n O �z J LJ ?z O 1J R: \Projects\7929 Parillo\ENGINEERING PLANS\7929 GP02.dwg 8/29/2022 2: C6 PM t 1 00 I ■) (F\ 1A/"ITF FnrC (P) PAVED FL I I I I I I —(E) 8" SEWER MAIN PER LEUCADIA WASTEWATER DISTRICT (P) PAVED FL - STREET OVERLAY FOR SWALE k6.49 I 86.4 66. 5 1 DROUGHT RESISTANT LANDSCAPING. 6" MINUS ROCK 4" DRAIN PIPE---, 1. W.=y I .0 90.0 IE 3" MIN. OF MULCH 12" BROOKS BOX OR EQUAL 12" F.S.=90.0 _ - - - lAIIIIII111L MR . `��l �l v7_1 DIN 4� III1.•..f.:;�1.•N*•��:,�1.•.f.:;�1..N*•��:,3�.,Zf�*"S;�dd�e'�4�si'A:S�d�' s2►:.n.��l_i rF� II _.�L�J■'�1 = 10 f 1 SDRSD RETAINING WALL "C-1" WATER PROOF SIDES OF WALLS -3" OF 3/8" GRAVEL 88.0 IE //v T.F=87.5 SOLID 4" PVC PIPE, OUTLET TO NEPTUNE *BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 65% SAND, 15% COMPOST OR HARDWOOD MULCH, AND 20% TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. **3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL. SOLID 4" PV OUTLET TO N SUMP PUMP & STORAGE SPECIFICATIONS (2) BARMESA PUMP 1 /2 HP 115v 1 PH 84 GPM 14' TDH (1) 122 - SJE RHOMBUS CONTROL PANEL (20-30 AMPS W/ BREAKERS) (3) LEVEL CONTROL W/O PLUG BOX (3) HAPPY FACE WEIGHTS - ZINC PLATED CAST IRON CORD WEIGHT (2) 2 TRUE UNION SWING CHECK VALVE (1) 2" PVC BALL VALVE (1) 36 x 72 FIBERGLASS BASIN W/ ANTI FLOAT 317 GAL (1) 36" TRAFFIC RATED STEEL COVER BROOKS BOX DETAIL NOT TO SCALE V4- PERF. UNDERDRAIN PIPE VOID FILLER - 1 /8" T "X16" PCC 3/8" (NO. 8) FLUSH CURB APPROVED PERVIOUS AGGREGATE IN VOIDS OR DEEPENED PAVERS W/ MIN. BEDDING COURSE - 2" THICK OF 1 TO 3/8" G-1 CURB 3/8" VOID I a: \� /8" , _ I / (NO. 8) AGGREGATEex a CHOKER COURSE - 4 THICK OF 3/8" TO 1 /2"�4" /////jj (NO. 57) CRUSHED ROCK MIN. 6" THICK---' OF3/4" CRUSHED ROCK WORK TO BE DONE: I 1D P.C.C. DRIVEWAY, SEE DRIVEWAY DETAIL ON \ SHEET 4. O2 PROPOSED CONCRETE BLOCK RETAINING WALL PER S.D.R.S.D. "C-1 ". WHICH REFERENCES IN x THERE TO SEE "C-7" & "C-8" FOR ADDITIONAL 9,31 NOTES & DETAILS, THE "C-8" DETAIL SHOWS WEEPHOLES WHICH WE WILL BE USING. O3 4" PVC DRAIN PIPE @ 0.5% MIN. 235 L.F. \ O4 6" AREA DRAINS. x 93 O 2'x2' 6" MINUS ROCK, PER S.D.R.S.D. D-40. \ O6 BIO-RETENTION BASIN PER DETAIL THIS SHEET, I FINISHED SURFACE = 90.0 O BIO-RETENTION BASIN PER DETAIL THIS SHEET, ID z FINISHED SURFACE = 90.0. Ln O INSTALL 8" "NDs" PRO SERIES CHANNEL DRAIN SYSTEM. USE PART NO. 838 TRAFFIC CHANNEL N GRATE & PART NO. 833 DEEP PROFILE DRAIN. I L4 9` O9 SUMP PUMP PER SPECS, THIS SHEET. 00 I 10 4" PERFORATED PVC PIPE, 15 L.F. �� 11 12" BROOKS BOX PER DETAIL THIS SHEET. z_ B 12 INSTALL A.C. PAVEMENT IN PARKING LANE ALONG FRONTAGE TO CREATE A 4.8-INCH RISE °? FROM WHITE EDGE STRIPING TO T. SEE SHEET 4 FOR NEPTUNE AVE. MORE DETAILED. cn 2 13 SUBDRAIN PER BUILDING PLANS, 140 L.F. 4' 0 14 EXISTING 1-INCH WATER METER TO BE N RELOCATED INTO THE RIGHT-OF-WAY BY SDWD. > 15 INSTALL SEWER CLEANOUT PER LWD S-25 ON z EXISTING SEWER LATERAL. N �4, � PROPOSED HATCHING LEGEND 54 9.T N 91.1 r PERVIOUS PAVERS Bw j (SEE DETAIL THIS SHEET) 90.04 TF C'j v GARDEN PLANTING 0 0 0 o PEA GRAVEL h❑ El El E-i E STEP STONES El Ll SURVEY NOTE: ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED -IN -PLACE. IF ANY MONUMENT IS DISTURBED OR DESTROYED IT SHALL BE REPLACED BY A LICENSED SURVEYOR. SOIL SUBGRADE ��//\\/� PERF. SUBDRAIN41 NOTES: -ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL - SUBDRAIN MAY BE REQUIRED. PERVIOUS PAVER DETAIL NOT TO SCALE Q�OFE5S/ON 9 5 2.5 0 N 5 10 C 39726 Civi SCALE IN FEET sTgTE OFcP, \FOR�\F SCALE: 1 = 5 NOTES: • NEPTUNE IS CONSIDERED A "SPECIAL CASE" FOR RIGHT-OF-WAY AND NO ADDITIONAL RIGHT-OF-WAY SHALL BE REQUIRED. • ALL UTILITY SERVICE LINES TO THE BUILDING SHALL BE CONSTRUCTED UNDERGROUND. RETAINING WALL NOTE: • TW = FINISH GRADE @ TOP OF RETAINING PORTION. NOT ARCHITECTURAL TOP OF WALL • BW = FINISH GRADE @ BOTTOM OF RETAINING PORTION. - NOT TOP OF FOOTING. • TF = TOP OF FOOTING EASEMENT NOTE: ONLY EASEMENT ON PROPERTY IS AN EXISTING EASEMENT FOR TELEPHONE AND/OR ELECTRIC POLES AND LINES FOR SEWER, WATER AND/OR GAS MAINS AND PIPE LINES AND RIGHTS INCIDENTAL THERETO, AS SET FORTH IN A DOCUMENT RECORDED ON JULY 6, 1944, IN BOOK 1715 PAGE 61, OF OFFICIAL RECORDS. THE EXACT LOCATION OF SAID EASEMENT CANNOT BE DETERMINED AND IS NOT PLOTTED. BMPs NOTE: BMPs ARE TO BE PRIVATELY MAINTAINED AND THE FACILITIES NOT MODIFIED OR REMOVED WITHOUT A PERMIT FROM THE CITY. SINGLE SOURCE DEVELOPMENT CONSULTANT 310 VIA VERA CRUZ, #205 SAN MARCOS, CA. 92078 (760) 510-3152 Ph / (760) 510-3153 Fax c CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS- DEVELOPMENT SERVICES DEPARTMENT DWG. N0. AJL AJL DEL DESCRIPTION: 2.5" CITY OF ENCINITAS BRASS DISC POINT ID 1025 LOCATION: IN A WELL MONUMENT STAMPED ENC-25 LS 7322 AT THE INTERSECTION OF EL PORTAL STREET AND LA MESA AVE. RECORD FROM: CITY OF ENCINITAS SURVEY CONTROL NETWORK ELEVATION: 60.601' DATUM: NAVD88 DOUGLAS E. LOGAN DATE PRINCIPAL ENGINEER DATE INT. DATE P NS PR ARED UNDER SUPERVISION OF DATE: 8 29 2022 R.C.E. N0. 39726 ENGINEER DOUGLAS E. LOGAN EXP. 12-31-23 CO M N APPROVED: �����0� MICHAEL STRIZIC JILL T. BANKSTON PRINCIPAL ENGINEER CITY ENGINEER 09/22/2022 09/27/2022 DATE DATE GRADING & DRAINAGE PLAN FOR: PARILLO RESIDENCE 1439 NEPTUNE AVE., ENCINITAS, CA 92024 CASE NO. CDP-004397-2021 APN: 254-221-03 I LDEV-017211-2021 c i PUBLIC WORKS PLANNING REVIEWER SHEET 3 OF 5 INSPECTOR O nv (n LiJ � U �ca) _LjU JJ � O -Lj� Q nW N Ln L �r10 7 � O Ln j CD n O �z JJ LLJ ?z .D O 77_ = 1J Q_ R:\Projects\7929 Pcri o\EN&NEERING PLANS\7929-GP03.dwg 8/29/2022 2: 25 PM SITE SECTION A SCALE: H & V: 1 " = 5' LINE OF ELEVATOR SHAFT BEYOND m �6 � 2 NEPTUNE- 85 — :• SITE SECTION B SCALE: H & V: 1 " = 5' 2oz 10, V.C. DRIVEWAY PROFILE SCALES: HORIZ.: 1" = 5' VERT.: 1 " = 5' (E) WHITE EDGE STRIPING ALONG NEPTUNE -10' -V. C (P) PAVED FL 10' PARKING LANE 2' I, 8' GE @ 82.5 TRENCH DRAIN 4.8" ABOVE FL ELEVATION OF SWALE SCARIFY (E) A.C. PAVEMENT & ADD NEW A.C. PAVEMENT AS SHOWN NEPTUNE AVE. A.C. PAVEMENT NOT -TO -SCALE 90 rem :• TOP OF ROOF i, i 01) u I CROWN OF (E) PAVEMENT I 1 �n 1 00 85.92x 6' I I WWIT� �nr-,� V6.29 3: I SDWD S XH IBIT E8' � (P) PAVED FL ATI86.39 x� 3 C/ x it 86.41 / / (86. tk 5� I / 2' 186. FROM (E) 8"" SEWER MAIN PER LEUCADIA WASTEWATER 86.48 DISTRICTtk I / c I (P) PAVED FL / 8 i �6.49 x 86.48 1 Ik 88 x 86.48 x / _B7. <� \ 90 ;.00 86. 5 I �i 8g I/ I 7 PLAN VIEW - NEPTUNE AVE. FOR DRAINAGE i N SCALE IN FEET ` SCALE: 1 " = 5' QROFESS/ON 9 JG�p,S E. Z C� m C 39726 A i7 iY PT CIVIC �P qTF OF CA0F I RANCHO COASTAL CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DWG. N0. AJL AJL DEL DESCRIPTION: 2.5" CITY OF ENCINITAS BRASS DISC POINT ID 1025 LOCATION: IN A WELL MONUMENT STAMPED ENC-25 LS 7322 AT THE DOUGLAS E. LOGAN DATE PRINCIPAL ENGINEER DATE INT. DATE P NS 7RARED UNDER SUPERVISION OF DATE: 8 29 2022LDEV-017211-2021 R.C.E. N0. 39726 ENGINEER DOUGLAS E. LOGAN EXP. 12-31-23 APPROVED: ��a�L O�PARILLO w2l�� MICHAEL STRIZIC JILL T. BANKSTON PRINCIPAL ENGINEER CITY ENGINEER 09/22/2022 09/27/2022 DATE DATE SITE SECTIONS &DETAILS FOR: RESIDENCEINTERSECTION 1439 NEPTUNE AVE., ENCINITAS, CA 92024 CASE N0. CDP-004397-2021 APN: 254-221-03 PUBLIC WORKS OF EL PORTAL STREET AND LA MESA AVE. RECORD FROM: CITY OF ENCINITAS SURVEY CONTROL NETWORK ELEVATION: 60.601' DATUM: NAVD88 PLANNING REVIEWER INSPECTOR SHEET 4 OF 5 I 7 O nU r Cn � w �n, �@) LJO O �0 LJ J Q nW N Ln L �o Liz O > Q0 7 � n o �z -LJ w ?z 7 O LJ � R:\Projects\7929 Pcri o\ENGINEERING PLAN S\7929—GPO4.dwg 8/29/2022 2: 26 PM STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT • CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS • A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES • A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL • EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. • NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. • DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. • REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. • TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. • PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. • WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE • STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING • CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT • CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. • NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. • MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. • POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. • PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. • ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE • FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. LEUCADIA WASTEWATER DISTRICT NOTES: 1. LWD APPROVAL OF THESE PLANS DOES NOT RELIEVE THE APPLICANT, PRIVATE ENGINEER OF WORK, OR CONTRACTOR FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING OR AFTER CONSTRUCTION. 2. ALL DESIGNS, MATERIALS, AND CONSTRUCTION WORK SHALL CONFORM TO LEUCADIA WASTEWATER DISTRICT (LWD) STANDARD SPECIFICATIONS, AVAILABLE ON THE LWD WEBSITE, AND TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREENBOOK) AND THE REGIONAL STANDARD DRAWINGS, MOST CURRENT EDITIONS. IN THE EVENT OF CONFLICT, THE LWD SEWER STANDARDS GOVERN. 3. OSHA SAFETY ORDERS AND OSHA CONFINED SPACE ENTRY REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES WITHOUT EXCEPTION. 4. THE CONTRACTOR SHALL HAVE A COPY OF THE DOCUMENTS LISTED IN SEWER NOTES 2 & 3 ON THE JOBSITE AT ALL TIMES. 5. NO WORK SHALL BE COMMENCED UNTIL ALL RIGHT-OF-WAY AND OTHER REQUIRED PERMITS HAVE BEEN OBTAINED FROM THE JURISDICTIONAL CITY, COUNTY, AND /OR APPROPRIATE AGENCIES. 6. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES SHOWN ON THESE PLANS OBTAINED BY AVAILABLE RECORDS SEARCH BY THE PRIVATE ENGINEER. TO THE BEST OF THE PRIVATE ENGINEER'S KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITIES OR STRUCTURES NOT SHOWN, OR IN A DIFFERENT LOCATION FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR SHALL TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND OTHER EXISTING FACILITIES OR STRUCTURES SHOWN. 7. APPROVAL OF THIS PLAN BY LWD DOES NOT CONSTITUTE A REPRESENTATION OF THE ACCURACY OF THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE, OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 8. CONTRACTOR SHALL BE AWARE THAT LWD FACILITIES PROVIDE WASTEWATER CONVEYANCE, TREATMENT, AND DISPOSAL TO THE PUBLIC 24 HOURS A DAY, 365 DAYS A YEAR. THEREFORE, LWD OR THEIR CONTRACTORS MAY NEED ACCESS TO FACILITIES FOR OPERATIONS, MAINTENANCE, OR EMERGENCY REPAIR AT ANY TIME. THE CONTRACTOR WILL ENSURE THAT ACCESS TO THE FACILITIES IS MAINTAINED AT ALL TIMES (DURING CONSTRUCTION AND AT THE END OF EACH CONSTRUCTION DAY) AND SHALL NOT HINDER AND WOULD BE EXPECTED TO ASSIST WITH ACCESS WHILE WORKING AROUND LWD FACILITIES. 9. CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO PROTECT LWD FACILITIES AND STRUCTURES DURING CONSTRUCTION. SHOULD THE CONTRACTOR AT ANY TIME DAMAGE LWD OR PRIVATE SEWER LATERAL FACILITIES, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK, NOTIFY LWD, MINIMIZE AND CONTROL ANY SEWAGE SPILL AND REPAIR DAMAGED FACILITIES TO THE SATISFACTION OF LWD AT NO COST TO LWD INCLUDING INSPECTION AND ANY BYPASSING REQUIRED. DAMAGE CAUSED TO SEWER FACILITIES SHALL BE REPAIRED IN ACCORDANCE WITH ALL APPLICABLE LWD STANDARD SPECIFICATIONS AND DRAWINGS. SUBMIT FOR LWD APPROVAL PRIOR TO REPAIR. 10. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PREVENTING SEWAGE SPILLS; CONTAINING ANY SEWAGE SPILLS; RECOVERY AND LEGAL DISPOSAL OF ANY SPILLED SEWAGE ARISING FROM ANY WORK ADJACENT TO LWD FACILITIES OR ALLOWING A SEWAGE SPILL OR FAILURE TO PREVENT A SEWAGE SPILL WHILE PERFORMING THE WORK. CONTRACTOR WILL BE RESPONSIBLE FOR ALL CLEAN-UP COSTS AND PENALTIES ASSESSED TO THE DISTRICT AS A RESULT OF A SEWAGE SPILL CAUSED BY THE CONTRACTOR. 11. CONTRACTOR SHALL NOTIFY LWD A WEEK IN ADVANCE OF PLANNED CONSTRUCTION ACTIVITIES IN THE AREA OF WORK POTENTIALLY AFFECTING LWD SEWER FACILITIES. 12. CONTRACTOR SHALL NOTIFY LWD 48 HOURS PRIOR TO EXCAVATION OF SEWER UNDER CROSSINGS, OVERCROSSINGS, OR PARALLEL INSTALLATIONS WHERE SEWER MAY BE EXPOSED. SAN DIEGUITO WATER DISTRICT NOTES 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND/OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6. MINIMUM HORIZONTAL SEPARATION OF 10-FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECT JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC-17 OR WC-18. W.25 a&n 32 29 I ,8 �n a& STABILIZED/ 5.92x ° I CONSTRUCTIO / EN RANCE/- I / / rn ee.4 I I � I#esoo xes. 8&48X I � / I I _ 1rCCINI,rI ur0LvrC rrCVIVI HINU ALONG THE LINE OF POSTS. 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. NOTE: LOWER BAG ROW TO BE BURIED 6" UNDER GRADE. GRAVEL BAG CHECK DAM NOT TO SCALE STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMPZIMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. IN (10 CM) x 9a2s 71 I I Uss 10 SILT FENCE 1 �;15 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. FILTER FABRIC - RE SILT FENCE DETAIL NOT TO SCALE 10 5 0 10 20 SCALE IN FEET SCALE: 1 " = 10' LEGEND PROPERTY BOUNDARY CONSTRUCTION ENTRANCE GRAVEL BAGS SILT FENCE 20'MIN. Ilk rPUBLIC 1 RIGHT-OF-WAY 8" MIN.-i-i-1 iiii-iii-iii-iii II I I III III -III -I PROFILE EXISTING 1-1/2" PUBLIC CRUSHED RIGHT-OF-WAY GROUND ROCK i. 20' M I N . i. No PLAN PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT-OF-WAY c STABILIZED CONSTRUCTION ENTRANCE QRoFESS/ON 9 JG�p,S E z C� m � C 39726 A sT vivo- �P qTF OF CAS-\F��� NOT TO SCALE RANCHO COASTAL c ENGINEERING & SURVLYING SINGLE SOURCE DEVELOPMENT CONSULTANT 310 VIA VERA CRUZ, #205 SAN MARCOS, CA. 92078 (760) 510-3152 Ph / (760) 510-3153 Fax CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DWG. N0. AJL AJL DEL DESCRIPTION: 2.5" CITY OF ENCINITAS BRASS DISC POINJATTH LOCATION: IN A WELL MONUMENT STAMPED ENC-25 LS 7 DOUGLAS E. LOGAN DATE ENGINEER DATE INT. DATE P NS PR ARED UNDER SUPERVISION OF DATE: 8 29 2022 N0. 39726 ENGINEER DOUGLAS E. LOGAN EXP. 12-31-23 CO M N APPROVED: ���t�n MICHAEL STNGI JILL T. BANKSTON PRINCIPAL ENGINEER CITY ENGINEERRECORD 09/22/2022 09/27/2022ELEVATION: DATE DATE EROSION CONTROL PLAN FOR: PARILLO RESIDENCEINTERSECTION 1439 NEPTUNE AVE., ENCINITAS, CA 92024R.C.E. CASE N0. CDP-004397-2021 APN: 254-221-03 LDEV-017211-2021 PUBLIC WORKS OF EL PORTAL STREET AND LA FROM: CITY OF ENCINITAS SURVEY CONTROL NET 60.601' DATUM: NAVD88PRINCIPAL PLANNING REVIEWER INSPECTOR SHEET 5 OF 5 O nU Cn L-Li n, �@) -LJO O �0 Q nW N Ln E I O Ln O > Q0 n o �z _Lj LLI ?z 7 O LJ R: \Projects\7929 Pcrillo\ENGINEERING PLAN S\7929-GP05.dwg 8/29/2022 2: 27 PM