2016-119 Electrical Distribution and Control (Plans)ELECTRICAL SYMBOLS INSTRUMENTATION SYMBOLS INSTRUMENT IDENTIFICATION LETTERS FIRST LETTER SUCCEEDING LETTERS INSTRUMENT OR OTHER COMPONENT TO BE LETTER MEASURED OR MODIFIER READOUT OR OUTPUT F- NORMALLY OPEN CONTACT O MOUNTED IN THE FIELD. INITIATING VARIABLE PASSIVE FUNCTION FUNCTION MODIFIER C.T. CURRENT TRANSFORMER �- NORMALLY CLOSED CONTACT A ANALYSIS ALARM INSTRUMENT OR OTHER COMPONENT TO BE B BURNER, COMBUSTION °� TORQUE SWITCH (SPECIFY WHEN OPEN) °`O COIL /INDUCTOR -�-_ MOUNTED IN AN AUXILIARY LOCATION 90% TORQUE C CONTROL NORMALLY NORMALLY ACCESSIBLE BY OPERATOR. D DENSITY DIFFERENTIAL Q CLOSED WHEENEDEPRESSEDITCH TRANSFORMER EMF oQa NORMALLY CLOSED LIMIT SWITCH X' Flc INSTRUMENT OR OTHER COMPONENT TO BE E VOLTAGE ( ) PRIMARY ELEMENT OPENED WHEN DEPRESSED MOUNTED ON MCB FRONT PANEL OR OTHER F FLOW RATE RATIO cmo ono FLOAT TYPE LIQUID LEVEL SWITCH, FR PHASE FAILURE RELAY PANEL MARKED. O� CLOSING ON RISING LEVEL G GRAPHIC fto W Flc INSTRUMENT OR OTHER COMPONENT H HAND HIGH OQ FLOAT TYPE LIQUID LEVEL SWITCH, TR, TIME DELAY RELAY NORMALLY INACCESSAB LE. (BACK PAN) I CURRENT (ELECT) INDICATE �° OPENING ON RISING LEVEL. VACUUM OR PRESSURE SWITCH, LR J POWER SCAN oho O LATCHING RELAY Pie Psi SINGLE INSTRUMENT OR OTHER K HML UK CONTROL STA. CLOSING ON RISING PRESSURE. COMPONENT HAVING MULTIPLE FUNCTIONS. TIME SCHEDULE LOW L LEVEL LIGHT ° VACUUM OR PRESSURE SWITCH, CR CONTROL RELAY M MOTOR MIDDLE OR OPENING ON RISING PRESSURE. INSTRUMENT OR OTHER COMPONENT TO BE INTERMEDIATE FURNISHED AND INSTALLED BY OTHERS N USER ISOLATOR, ORIFICE oo TEMPERATURE ACTUATED SWITCH, ISR INTRINSICALLY SAFE RELAY 0 IN THE FUTURE. 0 OPERATOR RESTRICTION CLOSING ON RISING TEMPERATURE. \ �E EDGE CONNECTORS P PRESSURE, VACUUM POINT TEST CONNECTION ° �/ TEMPERATURE ACTUATED SWITCH, ---- - - - - -- FIELD WIRING OPENING ON RISING TEMPERATURE. Q QUANTITY, EVENT INTEGRATE TOTALIZER LJ PANEL WIRING R RADIOACTIVITY RECORD FLOW SWITCH (AIR, WATER, ETC.) DUPLEX RECEPTACLE S SPEED /FREQUENCY SAFETY SWITCH �0 CLOSING ON FLOW INCREASE. (GFI) GROUND FAULT INTERRUPT - - COMMUNICATION T TEMPERATURE TRANSMIT FLOW SWITCH (AIR, WATER, ETC.) U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION OPENING ON FLOW INCREASE. � SIMPLEX RECEPTACLE (3) INDICATES QUANTITY OF SIGNALS (THREE) V VIBRATION VALVE DAMPER OR LOUVER 0 0 NORMALLY OPEN PUSHBUTTON, MOMENTARY CLOSE. BATTERY HYDRAULIC LINE W WEIGHT OR FORCE WELL +I i I i X RUN X -AXIS UNCLASSIFIED UNCLASSIFIED 0 I A NORMALLY CLOSED PUSHBUTTON, CAPACITOR PROCESS PIPING Y ---VENT/STATE/PRESENCE Y -AXIS RELAY , MOMENTARY OPEN. COMPUTE CONVERT SOLENOID DRIVER, ACTUATOR 0 o SELECTOR SWITCH, 2 POSITION N.O. Z POSITION Z -AXIS UNCLASSIFIED O SONIC SIGNAL DIMENSION CONTROL RESISTOR ELEMENT oZo SELECTOR SWITCH, 2 POSITION N.C. CI CHLORINE RESIDUAL H p A -_ DIODE x 7k CAPILLARY TUBING (FILLED SYSTEM) DP DIFFERENTIAL PRESSURE 0� 0 SELECTOR SWITCH, HAND - OFF -AUTO o METAL OXIDE VARISTOR 0 0 OHMS A.S. AIR SUPPLY (20 PSIG- EXCEPT AS NOTED) PH HYDROGEN CONCENTRATION Tu TURBIDITY r i INDICATING FUSE HOLDER Ss SUSPENDED SOLIDS INDICATED COMPONENTS ARE NOT SPECIFIED INDICATOR LIGHT, PUSH -TO -TEST XX A AMPERE SIZE SHOWN AS PART OF THE INSTRUMENT PACKAGE. 0 OXYGEN CONCENTRATION TRANSFORMER 2 — CABLE (MULTICOLOR OR COAXIAL) o FURNISHED WITH EQUIPMENT GENERAL NOTES FOR CONTROL DIAGRAMS: 1. ALL CONTROLS ARE SHOWN DE- ENGERGIZED. INDICATOR LIGHT, PUSH -TO -TEST O EQUIPMENT TAG REFERENCE 2. ALL CONTROL DIAGRAMS SHOW CONTROL FUNCTIONS ONLY 1/0 POINT REFERENCE PLC, 1/0 RACK, OR WHERE REQUIRED, SLAVE RELAYS SHALL BE INSTALLED. SINGLE POLE TOGGLE SWITCH C= ANNUNCIATOR PANEL ( "ON -OFF ",ETC.) EARTH GROUND 0 DRAWING REFERENCE ABBREVIATION LIST ■ A AMPERES G, GND GROUND N NEUTRAL SR SIMPLEX RECEPTACLE oho NORMALLY OPEN WITH TIME DELAY CLOSING. LOCATION SYMBOL AM AMMETER GFI GROUND FAULT CIRCUIT INTERRUPTER NA NON AUTOMATIC SS SELECTOR SWITCH O MOTOR STARTER CONTACTOR COIL AC ALTERNATING CURRENT HPS HIGH PRESSURE SODIUM (N) NEW SP SURGE PROTECTOR M AIC AMPS INTERRUPTING CAPACITY HS HAND SWITCH N.I.C. NOT IN CONTRACT SV SOLENOID VALVE °�° NORMALLY CLOSED WITH TIME DELAY OPENING. BAT BATTERY ICP INSTRUMENTATION CONTROL PANEL NP NAMEPLATE SWBD SWITCHBOARD NORMALLY OPEN WITH INSTANT CLOSING 0 SHEET NOTE TAG BC BATTERY CHARGER ISR INTRINSICALLY SAFE RELAY OT OVERTEMPERATURE TB TERMINAL BLOCK o C COMMON I, IND INDICATOR 0/L OVERLOAD DEVICE TR TIME DELAY RELAY AND TIME DELAY OPENING. EDGE CONNECTOR CB CIRCUIT BREAKER INST INSTANTANEOUS PB PUSHBUTTON TC TIMECLOCK NORMALLY CLOSED WITH INSTANT OPENING E� CNTL CONTROL KV KILOVOLT PCB PRINTED CIRCUIT BOARD TM THERMAL MAGNETIC 0-T-0 CPT CONTROL POWER TRANSFORMER KVA KILOVOLT AMPERES PC PROGRAMMABLE CONTROLLER TS TEMPERATURE SWITCH AND TIME DELAY CLOSING. CID CONTROL PANEL KW KILOWATT PLC PROGRAMMABLE LOGIC CONTROLLER TSP TWISTED SHIELDED PAIR ---- - - - - -� SOFTWARE CR CONTROL RELAY LED LIGHT EMITTING DIODE PL -1 PILOT LIGHT 1 TWP TWISTED PAIR ® NAMEPLATE CT CURRENT TRANSFORMER LCD LIQUID CRYSTAL DISPLAY PFR PHASE /POWER FAIL RELAY TYP TYPICAL ® FUSE ------ - - - - -- FIELD WIRING DC DIRECT CURRENT LA LIGHTNING ARRESTER PNL PANEL UG UNDERGROUND DR DUPLEX RECEPTACLE LCP LOCAL CONTROL PANEL POT POTENTIOMETER V VOLTS, VOLTAGE OHMS RESISTOR (FIXED) PANEL WIRING (E) EXISTING LPU LIGHTNING PROTECTION UNIT PR PAIR CABLE VM VOLTMETER EC `, EDGE CONNECTOR LOS LOCK OUT STOP PS PRESSURE SWITCH VFD VARIABLE FREQUENCY DRIVE ETM ELAPSED TIME METER COMMUNICATIONS EF EXHAUST FAN LR LATCH RELAY PT POTENTIAL TRANSFORMER WP WEATHERPROOF ETM ELAPSED TIME METER LS LOAD SPLITTER PTT PUSH TO TEST TR,XMFR TRANSFORMER SLfLLL HEATER BOUNDARY FUSE mA MILLIAMPERES PVC POLYVINYL CHLORIDE XP EXPLOSION PROOF FB FUSE BLOCK MB MAIN BREAKER PWR POWER (FUTURE) FUTURE MCC MOTOR CONTROL CENTER RR RUN RELAY FLTR FILTER MCP MOTOR CIRCUIT PROTECTOR RVSS REDUCED VOLTAGE FS FLOAT SWITCH MOT MOTOR OVERTEMPERATURE SOLID -STATE STARTER FVNR FULL VOLTAGE NON REVERSING MMS MOTOR MOISTURE SENSOR RVAT REDUCED VOLTAGE FVR FULL VOLTAGE REVERSING MS MOTOR STARTER AUTOTRANSFORMER DRAWING NOTES: THIS DOCUMENT CONTAINS INFORMATION THAT IS THE GENERAL DESIGNED CITY OF ENCINITAS CONFIDENTIAL AND PROPRIETARY PROPERTY OF AD a TES CONTROLS, INCORPORATED AND MAY NOT BE TESCO CONTROLS, INC. SYMBOLS LEGEND DRAFTED COAST HIGHWAY 101 SEWER PUMP STATION REHABILITATION COPIED, PUBLISHED, DISCLOSED, OR USED FOR ANY AN EMPLOYEE -OWNED COMPANY BD ELECTRICAL DISTRIBUTION AND CONTROL OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN .8440 FLORIN ROAD � 1 11 -13 -2017 8D AS INSTALLED CONSENT OF TESCO CONTROLS, INCORPORATED. SACRAMENTO, CA 95828 N (916) 395 -8800 REVIEWED DWG. STATUS DATE JOB NO. SHEET NO. DRAWING n REV DATE BY DESCRIPTION DRAWING SCALE : NOT TO SCALE WWW.TES000ONTROLS.COM AS INSTALLED 09 -06 -16 T -46076 2 OF 20 46076 -L1 M 1. y. IM41 i7e �OA a 240VAC, 34, 60HZ SOB o I I >0C o -------- - - - - -- — — — — — — — — — — — — — — -- — — — — 10 PMP -1 HP PUMPENO. 1 CPT1 500VA xi x2 100 128 F3 100B 1ODA 100A 6.25A 100N 101 HS -1 129 102 R OFF 102 HAND AUTO 1028 C 106 102C CR1 PUMP 14 X00 CALL 130 103 OOX 103 - -�3� — 1028 NC 108,133 CUTLER SVX9000 FHHAMMER HIM I 131 COMMUNICATION I CABLE 0 FROM 127 104 — CR105 0 132 A9 00°0 10ON 103 — —I — — 1026 132 6 +24V 105 133 IC�32A 133 g DI-1 START FWD > VFD BYPASS 1068 IC1 ISOLATION 10 102 FROM 127 106 106A C1 1 5A DI —2 106 CONTACTOR 133A XO 0 N0100,133 134 132 11 33A 9 100 SPEED A2 100B ' OCl NC 108 107 106D N0128 135 10 EXT. FAULT I 21 I 1006 100N NC —�— 108 CR1 108A CR5 108,6 C1 1086 BC1 HS -1 DI -4 RUNNING ' 108 I o0X I BYPASS 136 136 14 AUTO R01 22 CONTACTOR 102 124 0 NO 11 ,126,128,154 i I CR6 109 ^� 137 102 15 AUTO i 23 ' 137 VFD RUNNING PTT PB -1 I I N0125,152,DWG 46076 -12, 518 110 BC1 110 BYPASS RUNNING '— t38 DI -6 I I NC 108 1008 �� A LIGHT 138 112° 16 FAULT RESET 24 PTT RESET VFD i 111 139 20 READY FAULT 25 R RUNNING RESET � 1006 P--° / � PB -1 112 CR3 CR3 CR7 112 112A VFD I 140 VFD FAILED 148 112 FAULT 140 ❑ 1 26 I I 113 I CR7 NO 112,154, DWG 46076 -12, 524 N0113 1 1006 i 140 NC 141 " 141 +10V REF NC PTT s 114 I A VFD FAULT 142 SC1 2 ii 142 2 Alt+ VAUGHAN PMR1 1008>__o LIGHT MANUAL SPEED CONTROL n 143 10K OHMS i 143 3 GND 115 I 3 L1 N 4 H�o 116 i CR2 PT MOTOR OVERTEMP ' A LIGHT 144 VFD SPEED CONTROL A0+ ` 4 AI2+ OVERTEMP 118 1008 >--O FROM PLC AO 117 I 117 116 A 2 1 1 145 AO- 5 AI2- A01+ AI 18 + VFD SPEED STATUS I CR2 jHLD V TO PLC AI 118 11 MOTOR OVERTEMP 146 SHD I I GND A01— n1 --------- #--- - - - - -- 19 H� AI— CR4 NO 116,150,DWG 46076 -12, 516 119 I NC102 147 G SHD SEAL LEAK 120 CR4 120 I 120 10 9 120A MOTOR SEAL LEAK 148 HS -1 HS -2 NO 119,152,DWG 46076 -12, 522 121 NC 149 I 149 t49 PUMP 1 IN AUTO 149A 149A PUMP 1 OVERTEMP I 1498 1498 PUMP 1 IN VFD — — --- 3 6 PTT TO PLC DI CR2 TO PLC DI I TO PLC DI 122 EAK�GE PROBE s—° — — — — — — 4 5 RESET A MOTOR SEAL LEAK 150 � OOX 150 �� 150A i 1508 IJV 150A 1506 �TAS 1008 I>--o / I 118 PUMP MOTOR r worse r - - -- 2 7 i 151 151A 1516 123 Lw - - - - -- 1 8 151 "15 151 PUMP 1 IN HAND RUNNING IN VFD PUMP 1 SEAL LEAK 124 TO PLC DI TO PLC DI CR4 TO PLC DI 0 L -1 152 L-C, R 6 152A 1526 124. 77 -P2 124A CR5 PUMP L �� 120 LJ o I JL/1 FAILURE 137 125 CR6 125 153 153A 1538 N0108 153 153 PUMP 1 FAIL 153A RUNNING IN BYPASS 1536 VFD FAULT 137 NC 154 BC1 ETM1 ELAPSE TIME R5 154 TO PLC DI BC1 154A TO PLC DI CR3 1546 TO PLC DI 126 1 2 METER 154 154 h�J 1546 108 2 108 112 127 100B 10ON 155 TO 135 TO 132 DRAWING NOTES: ®' THIS DOCUMENT CONTAINS INFORMATION THAT IS THE MOTOR CONTROL CENTER DESIGNED CITY OF ENCINITAS zi Wiring change to keep VFDs powered CONFIDENTIAL AND PROPRIETARY PROPERTY OF AD a TOSCO CONTROLS, INCORPORATED AND MAY NOT BE TOSCO CONTROLS, INC. PUMP NO. 1 DRAFTED COAST HIGHWAY 101 SEWER PUMP STATION REHABILITATION 2 3 -26 -2018 BD REVISED AS INSTALLED Motor Saver Contact laced back COPIED, PUBLISHED, DISCLOSED, OR USED FOR ANY AN EMPLOYEE-OWNED COMPANY o .2 into control circuit p OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN 8440 FLORIN ROAD CONTROL DIAGRAM BD ELECTRICAL DISTRIBUTION AND CONTROL 1 11 -13 -2017 BD AS INSTALLED CONSENT OF TESCO CONTROLS, INCORPORATED. SACRAMENTO, CA 95828 0 (916) 395 -8800 REVIEWED DWG. STATUS DATE JOB NO. SHEET NO. DRAWING REV DATE BY DESCRIPTION DRAWING SCALE : NOT TO SCALE WWW.TES000ONTROLS.COM AS INSTALLED 09 -06 -16 T -46076 8 OF 20 46076 -06 M I • MA "sl IRE >OA o i 240VAC, 30, 60HZ OB o i i , --------------- - - ---� ---- - - - - -- 10 PMP -2 - - - - -- HP PMP N0. 2 9 UF' 12 500VA 200 228 200A F6 20ON 2008 200A 6.25A 201 HS -3 229 202 R9 202 HAND OFF AUTO 2026 C 106 202C CR8 2ooN PUMP X00 230 1 I 203 -�- - CR301 NO 208,233 FDHAMMER HIM 203 i - -I - - 2028 CUTLER NC 231 Q i SVX9000 COMMUNICATION CABLE 0 FROM 227 CR105 Q1 232 A9 co o 20ON 204 1 203 - - -{ - - 2028 232 6 +24V 205 233 IC2 2�32A CRS DI -1 233 8 START FWD > HS -4 ISOLATION 20 206 206 206 VFD BYPASS 206A C 206B IC2 CONTACTOR CR 233A DI -2 FROM 227 234 232 233A 9 PRESET SPEED XO 0 NO 200,233 A2 200B OC2 NC 208 - -- 206D DI -3 i - -- 207 i 235 10 EXT. FAULT 21 BC2 NO 228,228,228 i 1 2008 200N I OX 208 CR8 208 A CR12 2088 C 208B NC 236 DI -4 RUNNING 208 , BYPASS 236 HS -3 14 AUTO R01 22 202 224 0 CONTACTOR 209 N�206226,228,254 237 15 AUTO 23 237 CR13 VFD RUNNING PTT PB -2 202 I I NO 225,252,DWG 46076 -13, 618 210 BC2 210 A BYPASS RUNNING 238 0 238 DI -6 I i NC LIGHT 212 16 FAULT RESET I +Ff24] i [Z-1 208 200B >--o VFD RESET 211 FAULT RUNNING RESET 239 20 READY R02 25 1 2008 > PB -2 212 CR10 CR10 212 212A VFD 26 1 CR14 2�8 212 FAULT 240 ❑ I i 240 VFD FAILED i CR14 NO 212,254 NO 213 213 2008 i 240 NC 241 241 1 +10V REF NC PTT s 214 I A VFD FAULT 242 SC2 �2 v 242 2 A11+ VAUGHAN PMR1 200B� —o� LIGHT MANUAL It SPEED CONTROL it 215 3 L1 N 4 243 10K OHMS 243 3 GND j HLD 216 i CR9 PT MOTOR OVERTEMP A LIGHT 244 VFD SPEED CONTROL A0+ 4 AI2+ FROM PLC AO OVERTEMP 218 2008 �--0 v 217 i 217 216 A 2 1 245 :jHLD 5 AI2- A01+ 18 VFD SPEED STATUS CR9 n TO PLC AI 218 11 MOTOR OVERTEMP 246 I GND A01- CR11 NO 216,250,DWG 46076 -13, 616 219 I NC 202 247 G SHD SEAL LEAK 220 CR11 220 220 10 9 220A MOTOR SEAL LEAK 248 HS -3 HS -4 NO 219,252,DWG 46076 -13, 622 221 NC 249 249 249 249A 249A 1 2498 2498 - - - - - - - 3 - T2- 6 PUMP 2 IN AUTO PUMP 2 OVERTEMP ",112 PUMP 1 IN VFD 222 GROUND RESET PT / 00 250 �� TO PLC DI CR9 TO PLC DI TO PLC DI IGK�CE PROBE — — — — — — — 4 — T2+ 5 '�' MOTOR SEAL LEAK _ 250 250 c5u 250A 250A TAS ® 2008 >—o 218 223 PUMP MOTOR f° - - - -- 2 — T2— 7 i 251 251A 2511 —— ` — — — — — — 1 — T2+ 8 Q 251 I 251 PUMP 2 IN HAND 251A RUNNING IN VFD 2518 PUMP 2 SEAL LEAK TO PLC DI TO PLC DI TO PLC DI 224 CR12 252 252 252 CR13 252A 252A CR11 252B 2526 0 L -2 224 777 —P2 224A PUMP 2 237 220 CR13 225 FAILURE 225 253 253 253 253A 253A 2536 2538 237 NO 208 PUMP 2 FAIL RUNNING IN BYPASS VFD FAULT NC 254 BC ETM1 ELAPSE TIME CR12 TO PLC DI BC2 TO PLC DI CR10 TO PLC DI 254 254A 2546 226 208 1 2 METER 254 2 254 254A 2548 208 212 227 200B 20ON 255 TO 235 TO 232 DRAWING NOTES: ® MOTOR CONTROL CENTER AD CITY OF EN CI N I TAS THIS DOCUMENT CONTAINS INFORMATION THAT IS THE � DESIGNED �1 Wiring change to keep VFDs powered CONFIDENTIAL AND PROPRIETARY PROPERTY OF TESCE CONTROLS, INCORPORATED AND MAY NOT BE TESCO CONTROLS, INC. PUMP NO. Z DRAFTED COAST HIGHWAY 101 SEWER PUMP STATION REHABILITATION " 2 3 -26 -2018 BD REVISED AS INSTALLED Motor Saver Contact laced back COPIED, PUBLISHED, DISCLOSED, OR USED FOR ANY AN EMPLOYEE — OWNED COMPANY o Q P OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN 8440 FLORIN ROAD BD ELECTRICAL DISTRIBUTION AND CONTROL 2 circuit CONTROL DIAGRAM CC into control circ CONSENT OF TESCO CONTROLS, INCORPORATED. SACRAMENTO, CA 95828 a 1 11 -13 -2017 BD AS INSTALLED (916) 395 -8800 REVIEWED DWG. STATUS DATE JOB NO. SHEET NO. DRAWING REV DATE BY DESCRIPTION DRAWING SCALE : NOT TO SCALE WWW.TES000ONTROLS.COM AS INSTALLED 09 -06 -16 T -46076 9 OF 20 46076 -07 M t�•s� ���s� yI �.. 4 WARNING NAMEPI ATF (SEE DETAIL "A" AT a ° a a a °o a ° a 0 0 0 o a ° 0 0 ° 0 0 o � M D ° D ° o ° o ° a a a ° a o f _l 8.00' FRONT VIEW �_l 8. D0 "---�I FRONT VIEW (SHOWN WITH DOORS OPEN) C1D2 COMPARTMENT I CONDUIT /WIRE 12.210 FROM MCC ON THIS SIDE R.438 938 2" 14.00 SOLID BOTTOM CONDUIT /WIRE 9.58 FROM SUMP ON THIS SIDE O TOP VIEW (NON- HAZARDOUS SIDE HAS OPEN BOTTOM C1D2 COMPARTMENT HAS SOLID BOTTOM) 1 1 1 11 -13 -2017 1 BD I AS INSTALLED IREVI DATE I BY I DESCRIPTION COMPRESSION SEAL BETWEEN COMPARTMENTS IRWATAil • d 4.' k i §y1 1'- 12.00" 24.�O" SIDE VIEW PUMP POWER BLOCKS e�:z m�u10 11111 F i0 0 0 0 M 18.00" BACK VIEW 0 ® ® o ME o M 9�9 a 18.00' FRONT VIEW (SHOWN WITH DOORS OPEN) NON- HAZARDOUS COMPARTMENT 4 THIS DOCUMENT CONTAINS INFORMATION THAT IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF TESCO CONTROLS, INCORPORATED AND MAY NOT BE TESCO CONTROLS, INC. COPIED, PUBLISHED, DISCLOSED, OR USED FOR ANY AN EMPLOYEE -OWNED COMPANY OTHER PURPOSE WITHOUT THE EXPRESS WRITTEN 8440 FLORIN ROAD CONSENT OF TESCO CONTROLS, INCORPORATED. SACRAMENTO, CA 95828 (916) 395 -8800 DRAWING SCALE : NOT TO SCALE WWW.TES000ONTROLS.COM 0 COMPRESSION SEAL BETWEEN COMPARTMENTS SUMP TERMINATION PANEL ELEVATION NAME PLATE SCHEDULE WHITE TEXT ON BLACK BACKGROUND TAG # QTY TYPE SIZE INSCRIPTION 1 1 PLATE 1" x 4" SUMP TERMINATION BD ELECTRICAL DISTRIBUTION AND CONTROL CABINET 2 1 PLATE 1" x 4" PUMP NO. 1 REVIEWED DWG. STATUS DATE JOB NO. 3 1 PLATE 1" x 4" PUMP NO. 2 09 -06 -16 T -46076 19 of 20 PMP -2 NOTES: 1. 2" X 6" PLATE NAMEPLATE IS WITH 1/2" ENGRAVED LETTERING (TYP). 2. 1" X 4" PLATE NAMEPLATE IS WITH 1/4" ENGRAVED LETTERING (TYP). 3. 3/4" X 3 PLATE NAMEPLATE IS WITH 3/16" ENGRAVED LETTERING (TYP). 4. RING NAMEPLATE WITH 3/16" ENGRAVED LETTERING (TYP). 5. NAMEPLATES SHALL BE BLACK WITH WHITE ENGRAVED LETTERING. DETAIL "A" — WARNING NAMEPLATE WARNING EQUIPMENT CABLES TO PASS FROM CLASS 1 DIVISION 2 AREA TO AN UNRATED AREA. ALL COMPRESSION POINTS SHALL INCLUDE BLANK PLUGS FOR INSTALLATION WHEN CABLES ARE REMOVED. NOTES; 1. FIRST LINE IS 1/4" ENGRAVED LETTERING 2. OTHER LINES ARE 3/16" ENGRAVED LETTERING 3. NAMEPLATE IS RED WITH WHITE ENGRAVED LETTERS. 4. NAMEPLATE DIMENSIONS ARE 2 "H x 6 "W INSTALLATION NOTES; 1. ENCLOSURE MOUNTING DISTANCE PER NFPA820 REQUIREMENTS 2. SEAL CONDUITS PER NEC REQUIREMENTS ENCLOSURE CONSTRUCTION NOTES 1. EXTERIOR 14 GA. 316 STAINLESS STEEL AND INTERIOR 14 GA. COLD ROLLED STEEL ELECTRICALLY WELDED AND REINFORCED WHERE REQUIRED. 2. CONSTRUCTION WILL BE NEMA 3RX. 3. ALL NUTS, BOLTS, SCREWS AND HINGES WILL BE STAINLESS STEEL. 4. NUTS, BOLTS & SCREWS WILL NOT BE VISIBLE FROM OUTSIDE OF ENCLOSURE. 5. PLASTIC NAMEPLATES WILL BE PROVIDED AS REQUIRED. 6. CONTROL WIRING WILL BE MARKED AT BOTH ENDS BY PERMANENT WIRE MARKERS. 7. A PLASTIC COVERED WIRING DIAGRAM WILL BE ATTACHED TO THE INSIDE OF THE FRONT DOOR. 8. ENCLOSURE WILL BE FACTORY WIRED AND CONFORM TO REQUIRED NEMA STANDARDS. 9. INSTRUCTIONS FOR INSTALLING AND MAINTAINING BARRIER INTEGRITY WILL BE ATTACHED TO INSIDE OF DOOR. DESIGNED CITY OF ENCINITAS AD a DRAFTED COAST HIGHWAY 101 SEWER PUMP STATION REHABILITATION BD ELECTRICAL DISTRIBUTION AND CONTROL (;IG y cb REVIEWED DWG. STATUS DATE JOB NO. SHEET N0. DRAWING AS INSTALLED 09 -06 -16 T -46076 19 of 20 46076 -17 IM41 M