LDEV-013341-2020 (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBIUTY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE /N ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONS7TRUCRON, 7HE DESIGN CONSMUCRON STANDARDS OF 7HE CITY OF ENCINITAS AND 7HE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REW90NS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTON. 2 7HE SOILS REPORT 777LED "PRELIMINARY GE07ECHNICAL INV£S77GA77ON AND FOUNDATION RECOMMENDATIONS PROPOSED NEW MIN CONDOMINIUM UNITS WITH DETACHED ACCESSORY DWELLING UNITS" PREPARED BY ENGINEERING DESIGN GROUP DATED NOVEMBER IZ 2020, PROJECT NO, 206446-1, SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE /N ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMI7S FOR ANY CONSTRUCTION K1774/N PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMIS51ON SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTONS REQUIRED 70 PROTECT ADJACENT PROPER7ES DURING GRADING OPERA77ONS ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIWL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL. STATE AND FEDERAL SAFETY AND HEALTH STANDARDS LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING W WN ONE-HALF (112) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5.•30 P.M. AND 7..-30 A.M. NOR ON SATURDAYS SUNDAYS AND CITY RECOGNIZED HOLIDAYS 9. NO GRADING OPERATIONS SHALL COMMENCE UN71L A PRE -CONSTRUCTION MEE77NG HAS BEEN HELD ONSI7E WITH THE FOLLOWING PEOPLE PRESENT CITY INSPECTOR, CIWL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITME. THE PRE-CONS7RUCTON MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PRO,ECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF 7HE WORK UNDER 7HE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN AS GRADED CERTIFICATION' SHALL BE PROVDED STATING "THE GRADING UNDER PERMIT NO.. LDEV-013341-2020 HAS BEEN PERFORMED /N SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN' THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF 7HE CIWL ENGINEER KHO CERTIFIES SUCH GRADING OPERA TON. SUITABILITY OF ANY FILL MATERIAL. UPON COMPLE7ON OF GRADING OPERA77ONS HE SHALL STATE THAT OBSERVATIONS AND 7ES73 WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE S17E AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFTCAT70N ALL VEGETABLE MATTER AND ORECTONABLE MATERIAL SHALL BE REMOVED BY 774E CONTRACTOR FROM THE SURFACE UPON WHICH 7HE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. 774E EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTIH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPON981LIFY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15 CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED 70 FINISH GRADE TO PRODUCE SM007H SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXAVA7ON AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES ROOTS AND 07HER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO 774E DISPOSAL OF ANY IT THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE ClWS URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PRO7ECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED 07HERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROTECTION ON THE GROUNOI. IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPRO D IMPROVEMENTS ARE /N CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. �l�I.i7J.-Zd9X.7•.'6lti'71CGL��iC�17lT4X:.7i•:�.7x7JILiAL�PISd�iLl.94�1i ��ii9fit47•]Fi'�)<X99% SERVCES DIRECTOR MUST CONCUR KITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERNOES BEFORE GRADING ACTIWTIES ARE ALLOWED TO RESUME. 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, 1F HUMAN REMAINS ARE FOUND ON THE PRO,ECT SITE DURING CON57RUC77ON ACI77I4TY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMER/AN MONITOR, SHALL OCCUR UN77L THE CORONER HAS MADE THE NECESSARY FINDINGS AS TO OR/GIN AND DISP0,9770N PURSUANT TO PUBLIC RESOURCES CODE 5097.98 /F SUCH A DISCOVERY OCCURS A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY VINE QUALIFIED ARCHAEOLOGIST AND/OR THE ICA NATIVE AMERICAN MON/TOR). AND CONSULTARQV AND TRE47MENT COULD OCCUR AS PRESCR/ ED BY LAW. AS FURTHER DEFINED BY STA LAW, IHE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NODFIED /F THE REMAINS ARE SUBECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINARON AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN 5177) (IN PLACE%. OR IN A SECURE LOCATION /N CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE /N THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. NO.I DESCRIPTION STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM, 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/SMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILLNOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHAR D INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. SAN DIEGUITO WATER DISTRICT 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND/OR ADJUST TO GRADE ANY EXISTING WATER FACUTY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACUTIES MUST MEET CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACUTIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6. MINIMUM HORIZONTAL SEPARATION OF 10-FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC-17 OR WC-18. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWER - CARDIFF SANITARY DIVISION - 760-633-2770 B. GAS & ELECTRIC - SDGE - (7601-438-6200 C. WATER - SAN DIEGUITO WATER DISTRICT - 1-800-227-2600 D. TELEPHONE - SBC BELL - (760)-489-3411 E. CABLE TV - COX COMMUNICATIONS - (760)806-9809 X-2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)-633-2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633-2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT LAURA TAUBER AT (858) 922-3350, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON rTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT ONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. S. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (407). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. APPROVED DATE BENCHMARK DESCRIPTION: CONTROL POINT ENC48 LOCATION: ON THE NORTH SIDE OF SANTA FE DRIVE, 175' WEST OF THE 1-5 SB OFF RAMP TO SANTA FE DRIVE IN THE NW CORNER OF A Cl. RECORD FROM: ROS 18416 ELEVATION: 173.376' DATUM: NAV088 STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABIUZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. I46V 0aN-YTHaY8,T:a'MAI[01C2rIS*1111I.9:G1AMai711I 117,IN4C T FOR ALL ON -SITE. STOCKPILES BE COVERED OR PROTECTED WITH SOIL STABILIZATION BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES, WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. EARTHWORK DATA STEEPEST EXISTING NATURAL SLOPE ON -SITE = N/A, NO NATURAL SLOPES ON SITE MAXIMUM VERTICAL DEPTH OF CUT = 12 FT MAXIMUM VERTICAL DEPTH OF FILL m 2 FT CUT = 1,110 C.Y. FILL = 10 C.Y. EXPORT = 1.100 C.V. REMEDIAL = 400 C.Y. ( 400 REMOVAL AND RECOMPACTION UNDER AND 0 OUTSIDE OF BUILDING AREAS) ESTIMATE DOES NOT INCLUDE STRIPPINGS, UTILITY TRENCH VOLUMES OR ANY OVEREXCAVATION, IF REQUIRED BY SITE CONDITIONS. CONTRACTOR SHALL CONFIRM THAT ESTIMATES ARE CORRECT PRIOR TO COMMENCEMENT OF WORK. EARTHWORK QUANTITIES ARE ESTIMATED FOR PERMIT PURPOSES ONLY. (CALCULATED ON A THEORETICAL BASIS. ACTUAL QUANTITIES MAY VARY DUE TO SHRINKAGE OR SWELL FACTORS). REMEDIAL GRADING QUANTITIES ARE NOT ABLE TO BE DETERMINED. REFER TO SOILS REPORT FOR REMOVAL AND RECOMPACTION DEPTHS. DISTURBED AREA: 8.900 SQFT IMPERVIOUS AREAS ON -SITE IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 3.998 SQFT OFF -SITE IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 1.005 SQFT ON -SITE IMPERVIOUS AREA AFTER CONSTRUCTION: 4791 SQFT OFF -SITE IMPERVIOUS AREA AFTER CONSTRUCTION: 0 SOFT DECREASE IN IMPERVIOUS AREA: 212 SQFT IMPERVIOUS AREA REPLACED: 3A42 SOFT ZONING REQUIREMENTS R-11 (RESIDENTIAL - 11) OWNER/PERMI TTEE LRT VENTURES, LLC 461 MARVIEW LANE SOLANA BEACH, CA 92075 (858) 922-3350 SITE ADDRESS 1739-1741 SAN EUJO AVENUE CARDIFF, CA 92007 A. P. N.: 260-275-28-00 LEGAL DESCRIPTION PARCEL 1 OF PARCEL MAP NO. 16711, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CAUFORNIA, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO DECEMBER 13, 1991. TOPOGRAPHY PASCO LARET SUI7ER & ASSOCIATES PH 858-259-8212 DATE OF SURVEY: APRIL 24, 2019 VICINITY MAP NTS OWNER IS CERTIFICATE SUPERVISE OVEHEREBY R FRTIFY THAT ALL GRADING AACTIVIITY AND ADILS VISE ON THE COMR OR PACTION STABILIT HAS TY OFEN OUTHE SSIITE. RETAINED TO SIGNATURE [�1�t>• �v 'b6� DATE: 05-10-21 LAURA TAUBER FOR LRT VENTURES, LLC SOILS ENGINEER'S CERTIFICATE I, ERIN E. RIST A REGISTERED OWL ENGINEER /N THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN 774E FIELD OF APPLIED SOIL MECHANICS HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT KIRSH THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON SEPTEMBER 16, 2019. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE RENEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN /NCORPOR47ED IN THE GRADING PLANS AND SPECIFICATIONS SIGNED: DATE: 05-10-21 ERIN E. RIST Q(IOFESS/(y,. RCE NO.: 65122 EXP. DATE: JOB P. 206446=1 ENGINEERING DESIGN GROUP 2121 MON77EL ROAD SAN MARCOS CA, 92069 PROJECT NO.. 196180-1 PHONE.: 760-839-7302 ��r rraL,►�rz.�za.�rH►r►��:z.», r.�: C 65122 7HE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY 774E ENGINEER SHALL COMPLY K17H THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF VINE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE /N ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO VINE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES 7HAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS. AGENTS AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM 774E NEGLIGENT ACTS ERRORS OR OMISSIONS OF 774E ENGINEER AND HIS/HER AGENTS OR EMPLOYEES AC77NG K17HIN 7HE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF 774E WORK PERFORMED BY TIH E$, NGINEER. SIGNATURE DATE. �ypFESS/q,� BR/AN M. ARDOL/NO RCE No. 71651 (W�rE 0535 N. COASTHIGIWA&Y 101OCIAIESSOLANA BEACH CA 92074 2-3%-2f71651RCE EXPIRES 131 21/ / I BMP PROJECT STATUS STANDARD PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT 6/28/2021 /� L17IZIJohn U rob 6/9/2021 "Pe)s/zfi/zozl SIGN DATE N DATE SIGN DATE SIGN DATE SIGN DATE AS -BUILT APPROVALS Ni ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. TNT DATE PLANS PREPARED UNDER SUPERVISION OF REC I N APPROVED: GRADING PLAN FOR: PUBLIC WORKS n��7�'1111 DATE: 05-10-21 *A 1739-1741 SAN ELIJO AVENUE LDEV-013341.2020 BRIAN M. ARDOLINO DATE PLANNING lN� ST IOWAK .. .KSTON LAURA TAUBER, LTR VENTURES R.C.E. NO.: 71651 ACTING CITY ENGINEER REVIEWER n' 7-20-21 7/30121 APN: 260-275-28-00 SENIOR ENGINEER DATE BRIAN M. ARDOLINO EXP.: 12-31-21 DATE DATE INSPECTOREfl PLANNING CASE NO: 3288-2019 CDP; MULTI-003286-2019 SHEET 1 OF 8 ti c¢_ O y N ^ w3� y2i KQW m 002 �z0 ahm PLSA 3106 - - - - PROPERTY LINE - - CENTER LINE V EXISTING WATER LINE S EXISTING SEWER LINE 398 EXISTING CONTOUR LINE ® EXISTING STRUCTURE PROPOSED SETBACKS PROPOSED PERMANENT BMPAREA PROPOSED DECOMPOSED GRANITE PROPOSED PERVIOUS PAVERS 82 PROPOSED CONTOUR LINE PROPOSED RETAINING WALL ===g--- PROPOSED STORM DRAIN INLET ____ PROPOSED 4" PVC STORM DRAIN 1 \J PROPOSED SO PUMP TG TOP OF GRATE IE INVERT ELEVATION DG DECOMPOSED GRANITE PA PLANTERAREA FS FINISHED SURFACE FG FINISHED GRADE FL FLOW LINE FF FINSHED FLOOR FYSB FRONT YARD SETBACK SYSB SIDE YARD SETBACK RYSB REAR YARD SETBACK PIP PROTECT IN PLACE IMPERVIOUS, PERVIOUSANDTREATMENTAREAS PAVEMENT TYPE UNITIAREA(SF) UNIT2ARE4(SF) IMPERVIOUS PAVEMENT/BUILDINGS 2,393 SF 2,398 SF PERVIOUS LANDSCAPE AREA 1,285 SF 1,982 SF TOTALAREA 3.678 SF 4,380 SF REQUIRED BMPAREA 89 SF 85 SF PROPOSED TREATMENTAREA 84 SF 88 SF NOTES 1. ALL SERVICE LINES TO THE SUBJECT BUILDING SHALL BE CONSTRUCTED UNDERGROUND. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND/OR BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINT SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BY A LICENSED LAND SURVEYOR OR A REGISTERED CIVIL ENGINEER AUTHORIZED TO PRACTICE LAND SURVEYING. ACORNER RECORD OR RECORD OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE LICENSED LAND SURVEYOR OR THE REGISTERED CIVIL ENGINEER AS REQUIRED BYTHE LAND SURVEYOR'S ACT. 3. ALL STREET SIGNS, LIGHTS, LAMPS, UTILITIES, ETC. LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE PROTECTED IN -PLACE DURING CONSTRUCTION OR REPLACED TO THE SATISFACTION OF THE CITY ENGINEER. 4. CONTRACTOR TO FIELD VERIFY LOCATION, ELEVATION, AND CONDITION OF EXISTING SEWER LATERAL. EASEMENTS OF RECORD O1 SAN DIEGO GAS & ELECTRIC COMPANY HOLDER OF AN EASEMENT FOR PUBLIC UTILITIES, FLOES, WIRESAND INCIDENTAL PURPOSES, RECORDED DECEMBER 22, 19261N BOOK 1299, PAGE 142 OF OFFICIAL RECORDS. OSAN DIEGO GAS & ELECTRIC COMPANY HOLDER OF AN EASEMENT FOR PUBLIC UTILITIES, FLOES, WIRES AND INCIDENTAL PURPOSES, RECORDED DECEMBER 22, 19261N BOOK 11515, PAGE 407 OF DEEDS. VOID FILLER-]' TO'g°M0.8) AGGREGATE IN VOIDS CHOKERCOURSE4"THICK OFg'' T074'(N0.57) CRUSHED ROCK MIN. IT THICK OFj''CRUSHEDROCK PERVIOUS PAVERS W/ MIN.g°"VOID 6•X 18"PCC FLUSH CURB ORDEEPENEDG4CURB NOTE: .... .... ......-- -ALLAGGREGATE MUSTBE CLEANIWASHEOAND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENTOFNEXTCOURSE -NO IMPERVIOUSLINEROR FILTER FABRIC IS TO BE USED, EXCEPT FORS'FROM BUILDING SPECWL APPROVAL REQUIRED FOR USE W HIGHLY EXPANSIVE SOIL - SUBORAIN MAYBE REQUIRED "CONSTRUCTIONNOTE: -PAVERS TO BECOVEREDAND PROTECTED DURING CONSTRUCTION m \ i\ 1 i 1 1 1 1 1 1 11 l l I PROTECTEX B2,S BM / II, UMENTWPLACE M4'IP, LS 8518 1 Db°C6'Ld52' 8'FL 00 1 R -302456' Imo 802 !8 F 67LUSHCURS 11 TSTRKITTOINS LL PCOPPER WATERVERVIOUS' PAVER LATERALAND DUAL METER PER WAS y W OG C4RftTV/ALL dj N/ PA I ;DING ]s.i FS V 2D% }V✓B3.5' DISTRICTTOARANDON EXIST. WAMRIATERALANDMETER:� AT OWNER5EXPENSE �, CONTRACTOR TO VERIFYf L069TIONOFEXISTWATER \ iPo LATERALANDMETER \ RIGHTOFWAYCONSTRU&ION \ PERMITTOBEOSTAINED BY� DEVELOPERICONTRACTOR La 8'AC WATER SPRROX LOCATION) NOTE- STRIPING TO REMAIN, REPLACE PER TRAFFIC DIVIS+ON NOTE. CAP ABANDONED S€WER LATERALS of `I I \ I 2" HARDWOOD MULCH/GRASS COVER OR CITYAPPROVED EQUIVALENT TOP OF WALL = 83.5 SDRSD C4 RETAINING WALL PVC LINER/WATER PROOFING BETWEEN - WALL AND BMP FS = 79.1 WTCH ASPHALT 20% _W f]9.5F; 6'RB 35' CL TO PL ROCKWALL " 21'PERVIOUS I, PAVER DRIVE y0% ]A4'FL 179 Z, Nt- NI 5.0 ' D ICATION I \ \ FO PU IC ROAD IIII6p \ R 18]11 \I 1 \ i DROUGHTTOLERANT PLANTS (TYP.) TG = 83.0 r FG = 82.5 PL PA✓ERS 60, 1 15,11, 8.0011, 80 W BO.5BS 82585 W \ \ C-2RETWALL C pEG2 - PROTECTU.. r WALL PRECONCORNER T RECORDREWIRED CIM"IP, LS 7W -- I \ \ l I /ea 1 \ / I \ / R� I TOP OF WALL = 83.5 1 SDRSD C-4 WALL I 0.33' 18" LAYER ENGINEERED SOIL 'SEE NOTE BELOW F 2" LAYER OF 3/8" GRAVEL 1 6" LAYER OF 3/4" GRAVEL SEE NOTE BELOW FG = 80.2 4" PERFORATED UNDERORAIN, IE NOT TO SCALE • BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5%CLAY CONTENT. THE MIX SHALL CONTAIN 65%SAND, 15%COMPOST OR HARDWOORD MULCH, AND 20%TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. •• 3/4" CRUSHED ROCK LAYER SHALL BE MINIMUM OF 6" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED. ALL BIORETENTION PLANTERS TO BE DEPRESSED AT LEAST 6" BELOW ADJACENT FINISHED SURFACE BIORETENTIONAREA A' DETAIL, SECTIONA A NOT TO SCALE V aweao' 4.0'PVC p11.0%MIN 5'BY38;- ITS - _8Bd. 91.0'TS -8I6 BW :88.0'BS 4-PVC@TO%MIN B€^F5FS ,TV 87YF 6L5'FS' ILFG _ILWALL 91.1F 40"PVCSUAORAIN SUBORAIN PB3'FG ROOFORAIN & _��tMkfIN - O PUP FF Ts J�<P M i POINTOF CONNECTION / UNIT III I - T1 I )PAIN DRAIN 2ND FLOOR FF=96.3' / suMPPuMP FIRST FLOOR FF= 87.7' - / I GARAGE/BASEMENT FF=78.7-78.2 PAD=78.0' _ / FF=91.1' DRAINBYAco, / PAD=90.4' ✓EOEQUAL (��y�� I _ I _-I/ BASFEMENTLIMIT I ;non. ce rervo>mommw t j 1 I / I /" I HDRAWBYACO OVEDEQUAL NIT`2 / RDRAINDRAIN 2ND FLOOR FF=96.3' 'OsuMPPuMP I FIRSTFLOORFF=877 - GARAGE/BASEMENTFF=78.7-78.2 IIIFFF-91.V PAD=78.0' D=90.4' //UP& �' 1 WALLSUBDBAIN R DWM E �40PVCSUBORAIN TOSUMPPUMP PoINT01 ONNECRO 70 V� B76'1 cs wau \ \\ �Besrrs A_9.0 - Y' \ \ PROTECTBX l MONUMENTINPIACE \-91.9'11, - - Y4'N. LS 8508 PROTECTEX RETAINING - - - -gG_ WALLINPLACE SCALE: V" 10' ENCROACHMENT MAINTENANCE& REMOVAL AGREEMENT RECORDED JULY7 ,2021 AS DOCUMENT NUMBER 2021 - 0487685 OF O.R. 8" OVERFLOW RISER "SEE PLAN VIEW FOR TG AND FS ELEVATIONS DROUGHTTOLERANT PL PLANTS(TYP) l FG=93.0' nn' DER WAL I \ I leuncrae2 II 1 I I 1 I I I I I ( I I I I 1 I \ I I I I \ l \\ II \\ II AP I \ POWERFDLE III elTVe 2d' RYSR Off 1E BUILDING 5P SSS RETAINING WALL 939 ADU ROOFDR4W IT 918 41PVC II POINTOF I PRR9L1 ,_ CONNECIR*1 90.15'IE .TI WrFG 4C 1.lN.EE 1 -S &qv lIPNDSCAPE 9029E �I IV62"53'OB"€ 6499_ 3'N✓ 1 TWILL B DECORATIVE,�'� � LERIPRAP1314 $ \ ERVIOL 15' ' SAN ELIJO AVENUEµ 2% 30 2 "F PAVER60% PCC FLUSH CURB SECTION D-D NOT TO SCALE PL \ \ PROTECTIN➢lACE EaE @2%MIN r \ % �\ _EMOVE`OOVERHEADIC 1 IMTBIWFPLANTER B'2F \ / TJiP 93 PGP IE=90 fE.00' 1 Td IE r7 271 g2%MIN \ \ N I I 1 i� \. K I \ I 1 I g I \ \ .0� I A A I 1 I 1 \ 2 1 \ I W PROTECTEX. MONUMENTINPLACE Il2'SQ PMI, LS B548 F \I S \ \ " SCALE: 1= 10' 1 0 10 20 30 rS' DEDICATION FOR PUBLIC ROAD PER PM 16711 -s'-1 LANDSCAPE TOP OF EXISTING 6" OVERFLOW RISER 5 TG 90.5 BERM DROUGHTTOLERANT 1 PLANTS (TYP) TOP TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOTTOSCALE W CONCRETE HEADWALL TOP OF BERM kG AL OTHERWISE) cW� O fNiT ^ w3� y2i KQW m 002 Qzg ahm CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS -DEVELOPMENT SERVICES DEPARTMENT CONTROL POINT ENC48 ON THE NORTH SIDE OF SANTA FE DRIVE. 175' WEST OF THE I-5 SB OFF RAMP TO INT DATE PLANS PREPARED UNDER SUPERVISION OF DATE:282021 R.C.E. NO.: 71651 BRIAN M.A DOLINO EXP.: 12-31-21 REC I N APPROVED: "�,N ST IOWAK .. .KSTON ACTING CITY ENGINEER 7-20-21 7/30121 DATE DATEINSPECTOR GRADING PLAN FORLOCATION: 1739-1741 SAN ELIJO AVENUE LAURA TAUBER, LTR VENTURES APN: 260-275-28-00 PLANNING CASE NO: 3288-2019 CDP; MULTI-003286-2019 =DRANGJONDESCRIPTION: PUBLIC WORKS BRIAN M. ARDOLINO DATE PLANNING SANTA FE DRIVE IN THE NW CORNER OF A CI. RECORD FROM: ROB 18416 ELEVATION: 173.376' DATUM: NAV088 REVIEWER SENIOR ENGINEER DATE PLSA 310 STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. B. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. ADJACENT PROPERTY DISTURBANCE NOTE ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPUOWS PROPERTY. IF ANY DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORK, A WRITTEN LETTER OF PERMISSION FROM THE ADJACENT PROPERTY OWNER MUST BE OBTAINED AND SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ABMCENT PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AND SUBMITTED TO THE CITY IS GROUNDS FOR A STOP -WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION IS OBTAINED. I 1 1 W W a\ IFF154FLOGRO510' \\ 5 ONSTRUCTION 5; PTi7I \\ \ \\ II 11 A AV•\ R cE;=Hies' A I FIDGE cniknoF�ses' I ��\\ \l 1 I \ { I II II II II X I 'U�O \ S 9 S I S I. I I I O v@n�vn �e=+s' V ^ l I� II vv � INLErarsdrEciiQN O�0 \\ W W \ V. 1 & 0 O \V ever \ SILT FE v �\ \�-__� �� �� A A V 04zz'eq �-___ ___---- LEGEND PROPOSED SILT FENCE PROPOSED GRAVEL BAG BERM ® PROPOSED CONSTRUCTION ENTRANCE ADDITIONAL NOTES 1. EROSION CONTROL MEASURES (EG BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL ER09M ON SITE SEDIMENT COMM MEASURES (EG. SILT FENCING, FIRER ROLLS, GRAVEL 64GS) NOTE: MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE M4T'ERI4LS BIORETENTION BASINS SHAL BE EXCAVATED AND USED AS DESILTING 1. SET POSTS AND EXCAVATE A 2. STAPLE EXTRA STRENGTH SILT FENCE TO MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WINS DURING CONSTRUCTION THE SILT SHALL BE COMPLETELY 4 BY 41N (10 BV 10 CM) THE POSTS. POSTS ARE TO BE SPACED WIN MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEWA6910N DOWNSTREAM TRENCH UPSLOPE FROM AND CLOSER THAN STANDARD REMOVED AND THE BIORETFNTTON BASINS COMPLETED ONCE FINAL SITE GRAVEL BAGS OVERLAP ALONG THE LINE OF POSTS. PRE -MANUFACTURED SILT FENCE (EG. CONCRETE OR STUCCO WASHOUT AREAS, COVERED SMR40E AREAS FOR STABILIZATION IS ACHIEVED, PRIOR TO OCCUPANCY AND/OR FINAL ONTO CURB HAZARDOUS MATERIALS, PIACENENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE PRODUCTS. 2. NO DIRECTLY CONNECTED IMPWV)OUS AREAS (DOA) SHALL BE ALLOWED. OOA MEANS STORM RUNOFF GENERATED AND CONVEYED VA IMPERVIOUS ARE45, SUCH AS ROOF, ROOF DRAMA, DRIVEWAY, AND STREET. GREATER THAN 3"0 BUT / SMALLER THAN 6" 3. All PARCELS ARE SUBJECT TO DEVELOPMENT T SESGUI GUIDELINES FOR ABLEFUTUREA SINGLE-FAMILY RESIDENTIAL DEVELOPMENT. THESE GUIDELINES ARE AVAILABLE AT CITY FILTER FABRIC ' f HALL (505 S. WLGAN AVE, ENCINTTAS CA 92024) AND ARE APPROVED AS PER PC RES. 12" MIN. GRADE RUNOFF EXISTING 61N (15 CM) 2006-Y7 WITH ENDS OVERLAPPED LANDSCAPE EFFICIENCY BMP NOTES: SECTIONA-A 3. ATTACH THE FILTER FABRIC TO 4. BACKFILL AND COMPACT THE 1 NOTE: CONSTRUCT SEDIMENT THE POSTS AND EXTEND IT EXCAVATED SOIL. 1. ROUTINE INSPECTION TO GUARD AGAINST RUNOFF AND EROSION AND TO DETECT 20'R BARRIER AND CHANNELIZE RUNOFF INTO THE TRENCH. TO SEDIMENT TRAPPING DEVICE PLANT OR OF DEMON SYSTEM FAILURE IN. A TWO LAYERS OF GRAVEL BAGS 3 ERADICREPL4ATION NI F I DEAD DYING AND DISEASED YECETA)ION ` FILTER FABRIC ) 3. REPAIRING T OF INVASIVE SPECIES III 4. REPAIRING Tiff MULCH AS SYSTEM AND R$ COMPONENTS WHEN REQUIRED WIDTH A REQUIRED S REPLENISHING MULCH AS NEEDED TO ACCOMODATE 6. SOIL AMENDMENT WHEN NECESSARY TO SUPPORT AND MOUNTAIN HEALTHY ANTICIPATED_ - PLANT GROOM TRAFFIC s 7. FERTILIZING, PRUNING AND WEEDING AND MANTMNING TURF AREAS B. OWNER WELL E AVOID OBSTRUCTION OF MOTORISTS VIEWS A �® CORRUGATED 9. OWNER WILL BE G DEVISE TO FOR ALL I WIDERIGUIO SEE CALIFORNIA I STEEL PANEL$ RUNOFF TWO LAYERS OF GRAVEL BAGS A' 10. USE OF A TIMING DEVISE TO RUN ALL IRRIG4IION (W/&TIERY BACKUP) STORMWATER QUALITY F-25' MIN -I WITH ENDS OVERLAPPED 11. MAINTAIN THE SYSTEM CONSISTENT WITH dNWA (MAY APPLIED WATER ASSOCIATION (CA$QA) I Ny ALLOWANCE) STANDARD DWG. NO. TC-1 FOR GAP BETWEEN BAGS 12. REPLACEMENT OF VEGETATION TO BE CONSISTENT WITH PLANTS NIDROZONC ADDITIONAL INFORMATION ACTS AS SPILLWAY 1J. AN EH THE IRRICAIiON $FS7EN 10 NOT EXCEED M4WA (MAX APPLIED WATERALLTYPICAL STABILIZED CONSTRUCTION ENTRANCE TYPICAL INLET PROTECTION TYPICAL SILT FENCE F NOTTO SCALE S NOTE: GRADING INSPECTOR MAYALLOW CORRUGATED STEEL PANELS ONLY WITHOUTAGGREGATE. W c¢ a�n w3� S �_cQi 'Pxx KQW m 002 Qzg ahm SCALE: 1" = 20' 0 20 40 60 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: CONTROL POINT ENC48 LOCATION: ON THE NORTH SIDE OF SANTA FE DRIVE, ITS WEST OF THE I-5 SB OFF RAMP TO INT DATE PLANS PREPARED UNDER SUPERVISION OF DATE:262021 /II !� a�l R.C. E. N0.: 71851 BRIAN M.ARDOLINO EXP.: 12-31-21 REC I N APPROVED: "�'N 5T IOWAK .KSTON ACTING CITY ENGINEER 7-20-21 7130121 DATE DATE GRADING PLAN FOR: 1739-1741 SAN ELIJO AVENUE LAURA TAUBER, LTR VENTURES API: 260-275-28-00 PLANNING CASE NO: 3288-2019 CLIP; MULTI-003286-2019 LDEV-013341-2020 PUBLIC WORKS BRIAN M. ARDOLINO DATE PUNNING SANTA N THE CORNER OFACl. RECORD FROM: ROS 18416 RECORD FROM' ROB ELEVATION: 173.376' DATUM: NAV088 REVIEWER SENIOR ENGINEER DATE INSPECTOR SHEET 3 OF PLSA 3106 s DISTRO WATER LATEF s WASV VV kP $EWER ION. L19CATION) �ABAND,'INO �TEILAND / TO NERS EXPENSE / T01}EREY IN FEAST `, Z TERdi AND I IETER Is PROP. ygEW E}_______ LATERAC Y EX. 8'ACWAT 21 (APPROX. LOL W - DISTRK s WATER LATEM WAS N ON C F R�LS I I 1 l I I I , 314"IP,LSI8548 6"FLUSH CURB INSTALL VCOPPER FERVID) D DUAL ME7ER PER PAVER WC-1; OWNER'S PARKING EXPENSEW VV �9, IS (E) ROCK WALL PROP - (TO BE REMOVED) AL LATERAL 2.0% W RIGHT-OF-WAY g(/ 5 FS) /Y 4' FL 35 CL TO PL S I I I I / ) I 1 / / 1 / 111 1 I PROTECT MONUMENT 1 PBACE (60 1 T '949 i I I I I / / / / / / 4 DPA,N. IE C977 11LL IFc *7Ty) ^34'. IPLS 8548��8W \ 86I m/ PIP TWryyBBB B �Td BW795 2' I C-5 RE7 WALL S I 9.0% PROPERTY LINE PERVIOUS 4 I PAVERS g FS i� A 5 � � T-0 EASEMENT (E) 2-STORY RESIDENCE '^k PROPOSED TEMPORARY—' SHORING (SEE SHEET SH5) — ot, � O' IE 100R . I UNIT#1 BASEMENT/GARAGE rt� 6 TI F,. rnu-/o u y 4C0 ' 11 SLF _L L �1 ) I / �� \ �J I ( I / -yL�lxli Tw ITPROPERTY LINE PG \OE ROOF DRAIN NIO C NNE ION 1 g p _ POINT OF / CONNECTION U IT T - 0'IE + ADU UNIT#1 I l PARTIALLY COVERED. I Pao su Dr0111n1 IS PATIO TEMPORARY 1-1 SLOPE \ (BY OTHERS, TYPICAL) g1} \ BASEM NTLIMIT TG I I I Li Know what's below. Call before you dig. DIG ALERTII TWO WORKING DAYS BEFORE DIG ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT & GENERAL CONTRACTOR SHALL LOCATE 0 POTHOLE 1 (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL \ CONSTRUCTION BEGINS. 1 A STATE OF CALIFORNIA POWERPOLE DEPARTMENT OF INDUSTRIAL RELATIONS PROTECT N, DIVISION OF OCCUPATIONAL SAFETY AND HEALTH euwc 70, TRENCH/EXCAVATION PERMIT NO. VVLHNLAU A CTRIC ,11'CO TEN STEEL BI _ANTER OP=94.O', FG =907' 1 I 1 1- I III I I � �.. - �=` `�� �� �2NDSTORY `� 6 \ OVERHANG 911VG tiv 3:1 II UNIT 21 3,1 I -6'­T(�ENCHC-' -�_ -96_ UNIT #2BASEMENT/GARAGE �� (`9 V LANDSCAPE V 9 2 I1 4C0!OR AP -- 98 1E _ TROLLY aO' PROPERTY LINE GARAGEv �' - _..PAR, t 7pppn\ R B 1.TAD=78.Q' I - PI41TIO 1 '. L — — — —- _ W .0% e v A LI I - - f PROPOSED TEMPORARY 1W @J o �� 90.251E \ ADU UNIT#2 1 I AL W '\ 83.0) r4 L LF SHORING (SEE SHEET SH6) JNIT2 a A'HU I / !STALL i"COPPER OG 79.4' .0' ! 91.1'FG a FF=Bq.8 EXPENSE -- - -IJ — 92S PAD=91\i \ DUAL METER PER PERVIOUS VC 17 AT OWNER'S PAVER 5' / L-- -to PARKING ROOF DRAIN - 14'AC A POINT OF \ '� _ 9j CONNECTION \ 6" FLUSH CURB _ V 79.2'FS 79.1'FL 1 80. FS 179-8.'IE 15 -- - 13 - 101 '1 / V 90.15'IE \ 5.00'DEDICATION LB RETW L - 90.1, 94.7'FG, ^DRAIN 79.6' \ PROPERTY LINE J 1 F II t % \ 94�7 I 2 / \ FOR PUBLIC ROAD 1 \ - - BMPARE� > - 011 TG \ PERPM16711 4E IPOTECTEX. A V / _ ova gpp�- (E)CMUWALL 'IE m �I 1 ^U I MIONUMENTWPLACE e'SYS� .,..nrc 4'�IP, LS 8548 A ( / �92 �LL Nrt,PTEX 89. GN E 6439'_ 933Tvl V 1MOfJUMENT PLACE "TVV _ !'rFX RFT9ININ(,' �� 1 3/4"IP,LS8548 6 \� .ONU ENTI WALL PROPERTY LINE DECORATIVE CQBBLERIP / / / (3. 4' / I ryry11ONUMENTS8548E /6 EXISTING RESIDENCE \ V _ - - PAP A \ \ \ h/2^SD PIN, L58548 L STRUCTURAL REVIEW PERFORMED BY ESGIL, A 11 I \ I 1 AV ,SAFEBUILT COMPANY, AS PLAN CHECK I I A 1 / LDEV-013341-201.e, DATED 5/3/2021 BA' \ I 1 ri-run T.O.W. = TOP OF SOLDIER BEAM WALL B.O.W. = BOTTOM OF SOLDIER BEAM WALL BY OTHERS = WORK OUTSIDE SHORING SCOPE (P)= PROPOSED (E) = EXISTING PROPOSED IMPROVEMENTS IMPROVEMENT SYMBOL TEMPORARY SOLDIER BEAM I TEMPORARY TIMBER LAGGING SOLDIER BEAM COUNT O DETAIL/SECTION CALLOUTS X SHX 3x12 DF#2 TIMBER LAGGING SHORING DESIGN GROUP � ppFE55/pU- 0 4 8 16 24 C 80503%W7 GRAPHIC SCALE: 1" = 8' Ex , 3/31 /21 C �P 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 LCMNGE DESCRIPTIONDESIGNED BY: APPROVED GATE BENCHMARK AS -BUILT APPROVALS RPR T3R DRAWN BY: RPR CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS -DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: CONTROL POINT ENC 48 INT. DATE PLANS PREPARED UNDER SUPERVISION OF REC01 D APPROVED: SHORING PLAN FOR: LOCATION: ON THE NORTH SIDE OF SA14TA FE DRIVE, 175' ROY P REED DATE PUBLIC WORKS DATE: -- 1739-1741 SAN ELIJO AVENUE LDEV-013341-2020 WEST OF THE I-5 SB OFF RAMP TO SANTA FE DRIVE IN THE NW PLANNING ST INAK LT.BAN KSTON LAURA TAUBER, LTR VENTURES CCORNER OF A CI. SEE RIGHT R.C.E. NO.: 80503 INTERIM CITY ENGINEER RECORD FROM: ROS 18M SENIOR ENGINEER DATE REVIEWER 7-20-21 713W21 APN: 260-275-28-00 ELEVATION: 173.376 DATUM: NAVD88 INSPECTOR ROY P REED EXP.: 3/31/21 DATE DATE PLANNING CASE NO: 32H 2019 CDP; MULTI-003286-2019 SHEET 4 OF 8 PLEA 310E 8 SPACES @ 8'-0" O.C. = 64•-0" 90.00' EXISTING GRADE —i 90.00• T.O.W. = 88.09 T.O.W. = 89.00' T.O.W. = 87.00' T.O.W. = 86.W T.O.W.=85.00' _ T.O.W.=85.00' — — B.O.W. = 84.09 � I 80.00, — — 80.00• B.O.W. = 79.0w9 3 8.00' SH7 IB.O.W.= — _ — ,T=i 6: .W.= 7700, I SB#9 �J SB#1 TEMPORARY SOLDIER BEAM LEGEND: L J (SEE SCHEDULE FOR SIZE) T.O.W. = TOP OF WALL SB#2 L J L J SB#3 SB#4 B.O.W. = BOTTOM OF WALL L J J L J NOTES: SB#5 SB#6 SB#7 L J DESIGNATES 3x12 PRESSURE 1. SEE SOLDIER BEAM SCHEDULE ON SHEET SH7 FOR SHORING ATTRIBUTES. SB#8 TREATED LAGGING DF#2 2. POTHOLE/FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. PROFILE -LOOKING NORTH 3. LAGGING ABOUT THE LOWER 2'-0" MAY BE OMITTED FOR EXCAVATIONS MADE WITHIN DENSE TERRACE DEPOSITS/SANDSTONE. ONSITE GEOTECHNICAL ENGINEER TO CONFIRM. SCALE: 1" = 16/3 f 1 / (E) 2-STORY RESIDENCE OTECTEX NUMENTt�IN tEE�R EX. (E) NEIGHBORING WALL %4CE 8548 RD ��'7" � '9N PRovosEERETAINING IONUACE q , 1 wALL (SEE RETAINING DWG) ��3 � 4" IN It C-2 RET W LL \ TW 870' g SH7 lam T 80.0' W 83. 890 TC� X� 1' CORT PROPERTY LINE COBBLE 4'� (E) NEIGHBORING WALL 2 82 d LATER T P-50. ' 2 FL R ?0 - -4:0"PVC 1.0% B r-5". nc F 1 2 3 4 5 6 _ _ 7 8 9 I X o— n 40 �- FLUS'� 2-af BMPA 625 — IE — YSEi TALL 1 PERVIOU y �_ z 6' - - — — - v _ "PVC Loo 9 1.FFC FD 3/4" JAL MIE) RocK wALL - — — - (TO BE REMOVED) JIP LS T'"' I T '' -17ATS DG 8r�8 PROPERTY LINE - PROPOSED TEMPORARY 93. OF EOE PIP � ,,��aa.0 85I SHORING (TYPICAL) 1 BDFL7 OFD In EGVVW IyyPROPOSED SUMP SH7 Its INT 0 BWI(SEE CIVIL DWG) /o- :', '� C NNE ION 7 �� 55'-D =T WALL r1 naYT 1 U IT o EASEMENTo PROPOSED SITE DRAIN SS - .0% S 1 UNIT #1 BASEMENT/GARAGE I 1R r� y6. � { (SEE CIVIL DRAWINGS) - DD/1D CCln/Cp PROPOSED DRIVEWAY _ PARTIALLY PROPOSED LATERAL FI k`_II COVERED, RIGHT-OF-WAY L (SEE CIVIL DRAWINGS) PERVIOUS GARAGE/6I J / .2 TEMPORARY 1-1 SLOPE y7 nnn mu �...�,.•..>_,.... II PAVERS i- fi"T FNCH DRAT Y 1 •�:- (BY OTHERS, TYPICAL) PERVIOUS PA I FO R M0�/E E 1 AD=�B. / III 1 SHORING DESIGN GROUP y� ppFESS/ 0 4 8 16 SCALE:1"=15/3' 7727 CAMINITO LILIANA `- SAN DIEGO, CA 92129, (760)586-8121 DESIGNED BY: DRAWN BY: CHECKED BY: CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS RPR T3R RPR ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: CONTROL POINT ENC 48 INT. DATE PLANS PREPARED UNDER SUPERVISION OF REC01 D APPROVED: SHORING PLAN FOR: LOCATION: ON THE NORTH SIDE OF SA14TA FE DRIVE. 175' PUBLIC WORKS DATE: -- 1739-1741 SAN ELIJO AVENUE WEST OF THE-5 SB OFF RAMP TO SANTA FE DRIVE IN THE NW ROY P REED DATE LDEV-013341-2020 WESTOR HE 1-5 PLANNING R.C.E. NO.: 80503 ST I PAK LL T. BANKSTON LAURA TAUBER, LTR VENTURES CCORNERECORD FROM: ROS 18146 SEE RIGHT INTERIM CITY ENGINEER APN: 260-275-28-00 SENIOR ENGINEER DATE REVIEWER ROY P REED 7-20-21 7130121 ELEVATION: 1]3.3]6' DATUM: NAVD88 INSPECTOR EXP.: 3/31/21 DATE DATE PLANNING CASE NO: 32882019CDP SHEET 5 OF 8 L I PLEA 3106 a 7 SPACES @ 8'-0" O.C. = 56-0" 90.00' 90.00' T.O.W. = 90.00' — T.O.W. = 89.00' I T.O.W. = 87.00' EXISTING GRADE T.O.W. = 86.00' B.O.W. = 85.00' _ T.O.W. = 8=.00' T.O.W. = 84.00' —T.O.W.=83.00' -H- — 80.W 80.00' 3 =— --- -- — — — — — — — < r r B.O.W. = 77.W -TIr;l Boo se#10 77.00 I I I I I I I I I I I I I IN 70.00' ° 70.00' I I I I I I I I LEGEND: L J L J T.O.W. = TOP OF WALL L J J SB#15 L J SB#17 B.O.W. = BOTTOM OF WALL NOTES: SB#13 SB#14 SB#16 L J DESIGNATES 3x12 PRESSURE 1. SEE SOLDIER BEAM SCHEDULE ON SHEET SH7 FOR SHORING ATTRIBUTES. ` J SB#12 TREATED LAGGING DF#2 2. POTHOLE/FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. SB#11 PROFILE -LOOKING SOUTH 3. LAGGING ABOUT THE LOWER T-0" MAY BE OMITTED FOR EXCAVATIONS MADE WITHIN DENSE TERRACE DEPOSITS/SANDSTONE. ONSITE GEOTECHNICAL ENGINEER TO CONFIRM. SCALE: 1" = 16/3 1VLIO030 30V7d NI 77VM — �4Q}I3i PROPERTY LINE �� 9b99 S7 'dl °blE \ \ — -- — Ml , A 3OV7d 1N3PVnNOW � v X310111 EXISTING RESIDENCE --- \ S— — �� 3OV7d NIlN3wnNOPV j,0 / (E)CMUWALL �� �� L X31O31o�ld I6L91WdHAC h_41�aedwa avow onend a ,�.06 _ ,I,� 68 I PROPERTY LINE 7 \ NOI1V01030 ,O( 2 v B'-0., 7 M 13a �e L 1 70 _ 6 l6 O l' L 3 SH7 7° V�I � �I ,8'6L Sd 9'09 7-4 V6L ' 11 12 13 — 14 6 15 — 16 — 17 94'06 \ -_2'-9.1 - - - -:Zi 2 -6^ — — ,ize /� `J ,PROPOSED LATERAL \ 92 Oj 1L6 lINn1� PROPOSEDTEMPORARY �� 10'9 ,b'6L z001 N 1 SHORING (TYPICAL) '. MI. /1'fA / M ,h dW� ` SH7 - �, ,ciWn PROPOSED SUMP lWd 8(1$ — — 3l l . (SEE CIVIL DWG) I d 5 0 D < Nlb' -400 •� �� - m M9 �� ,Oi �O88M1 EASEMENT Oils .snOinL13d TEMPORARY I-1 SLOPE L. b (BY OTHERS, TYPICAL) ' %O'Z PROPOSED DRIVEWAY > Lu ^ J� . UNIT #2 BASEMENT/GARAGE I ! 7 7 0 7 (lO3 73Vd RIGHT-OF-WAY ` A77bI121t d PROPOSED SITE DRAIN ry , d G , 1S21I� 9AO8ddvao `ow T4PPn„96 1i� 21001� aNZ a NleaO HON3 1 yJRTY LINE lD (SEE CIVIL DRAWINGS)�'llNn n� 9ti6� SHORING DESIGN GROUP ppFE55/0�- p�P 0 4 8 16 � C80503 � BCALE:1°=16/3' 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 DESIGNED BY: DRAWN BY: CHECKED BY: CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS RPR T3R RPR ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: CONTROL POINT ENC 48 INT. DATE PLANS PREPARED UNDER SUPERVISION OF REC01 D APPROVED: SHORING PLAN FOR: LOCATION: ONTHENORTHSIDE OF SANTA FE DRIVE. 175' ROVPREED DATE PUBLIC WORKS DATE: 1739-1741 SAN ELIJO AVENUE LDEV-013341.2020 WEST OF THE I-5 SB OFF RAMP TO SANTA FE DRIVE INTHE NW PLANNING ST IPAK LLT. BANKSTON LAURA TAUBER, LTR VENTURES CCORNER OF A Cl. SEE RIGHT R.C.E. NO.: 80503 INTERIM CITY ENGINEER RECORD FROM: ROS 18M SENIOR ENGINEER DATE REVIEWER 7-20-21 7/30121 APN: 260-275-28-00 ELEVATION: 173.376 DATUM: NAVD88 INSPECTOR ROY P REED EXP.: 3/31/21 DATE DATE PLANNING CASE NO: 32H 2019 CDP SHEET 6 OF 8 a 2i t m, Q p w m IS o PLEA 310E SAFETY CABLE RAILING, PER CAL-OHSA REQUIREMENTS (TYP., AROUND ENTIRE SHORED PERIMETER, SEE 4/SH7) H„ PAD ELEVATION 42" (MIN.) SEE ELEVATION FOR SPACING - SOLDIER BEAM DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL TIMBER LAGGING, TYPICAL FILL VOIDS BEHIND LAGGING fff MATERIAL) (SEE ELEVATION FOR SIZE) -, .. r: �....-i WITH LEAN CONCRETE - 5 SACK SLURRY SHAFT 1CKFILL (T.O. W. TO B.O.W) I. (MIN.) TIMBER LAGGING 20d COMMON NAIL FOR LAGGING BEARING (SEE ELEVATIONS) INSTALLATION (TYP., AS REQ'D) NOTES: 1. BOUNDARY LINES SHALL BE STAKED PRIOR TO DRILLING BY PROJECT SURVEYOR. (SEE NOTE 3) 2. OFFSET BEAMS IN DRILL SHAFT AS REQUIRED FOR SHORING PLACEMENT. 2 SOLDIER BEAM PLAN DETAIL (TYPICAL) 2,500 PSI CONCRETE SHAFT SH7 N.T.S. BACKFILL (B.O.W TO PILE TIP) -� - SOLDIER BEAM (SEE SCHEDULE FOR SIZE) 11= NOTES: 1. FIELD VERIFY ALL EXISTING & PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. SEE SOLDIER BEAM SCHEDULE ON SH8 FOR VARIABLES "H", "D", E "Dshaft". 3. LAGGING ABOUT THE LOWER 2'-0" MAY BE OMITTED FOR EXCAVATIONS MADE WITHIN DENSE TERRACE DEPOSITS/SANDSTONE. ONSITE GEOTECHNICAL ENGINEER TO CONFIRM. TEMPORARY CANTILEVERED SOLDIER BEAM (TYP.) NO. I DESCRIPTION APPROVED I DATE 2" L2x2x3/8 ANGLE IRON ATOP - EACH SOLDIER BEAM MEMBER 3/8-inch 0 WIRE ROPE � T ALONG ENTIRE SHORING 21" I PERIMETER (TYP.) I 44" 174" L=6" EACH BEAM SOLDIER BEAM, TYP. (SEE SCHEDULE) DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL MATERIAL) CAL -OSHA GUARDRAIL DETAIL $H] N.T.S. TIMBER LAGGING (SEE ELEVATION) ///. %\\\r. • % %1\� /I TIMBER LAGGING (SEE ELEVATION) 20d COMMON NAIL FOR LAGGING INSTALLATION (4 PER BOARD) TIMBER LAGGING DIAGONAL SUPPORT DETAIL $H] N.T.S. SOLDIER BEAM SCHEDULE maximum Ice IDial Ioe From To Beam Beam Shored Depth Drill Diameter Beam Beam Qty Section Height Depth H D H+D Dshaft ft ft ft in 1 1 1 W 14 x 30 6.0 11.0 17.0 24 2 2 1 W 14 x 30 7.0 13.0 20.0 24 3 4 2 W 16 x 36 9.0 13.0 22.0 24 5 6 2 W 16 x 40 10.0 14.0 24.0 24 7 7 1 W 18 x 50 11.0 14.0 25.0 24 8 8 1 W 18 x 60 12.0 16.0 28.0 24 9 10 2 W 14 x 30 5.0 10.0 15.0 24 11 11 1 W 18 x 60 13.0 17.0 30.0 24 12 12 1 W 18 x 60 12.0 16.0 28.0 24 13 13 1 W 16 x 40 10.0 14.0 24.0 24 14 14 1 W 16 x 36 9.0 13.0 22.0 24 15 15 1 W 14 x 30 8.0 12.0 20.0 24 16 16 1 W 14 x 30 7.0 13.0 20.0 24 17 17 1 W 14 x 30 6.0 11.0 17.0 24 SHORING DESIGN GROUP ppFE55/ `a' oz u=F C 80503 = c OP c z_r C �P 7727 CAMINITO LILIANA i S; SAN DIEGO, CA 92129, (760)586-8121 i 9; d DESIGNED BY: DRAWN BY: CHECKED BY: BENCHMARK AS -BUILT APPROVALS KPK I TJR I KPK ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING IN �NTROL POINT Ervo4e INT. DATE PLANS PREPARED UNDER SUPERVISION OF REC01 D APPROVED: SHORING PLAN FOR: 1E NORTH SIDE OF SANTA FE DRIVE, 175' PUBLIC WORKS DATE: 1739-1741 SAN ELIJO AVENUE SB OFF RAMP TO SANTA RE DRIVE IN THE NW ROV P REED DATE LDEV-013341-2020 PLANNING STEWNOWAK tr. eANKsroly LAURA TAUBER, LTR VENTURES SEE RIGHT R.C.E. NO.: 80503 INTERIM CITY ENGINEER APN: 260-275-28-00 0518146 SENIOR ENGINEER DATE REVIEWER 7-20-21 7/30121 376 DATUM: NAVD88 ROV P REED 3/31 /21 INSPECTOR Exp,; DATE DATE PUNNING CASE NO: 32H 2019 CDP SHEET 7 OF 8 PLBA 3106 GENERAL NOTES 1. CONSTRUCTION PLANS AND CALCULATIONS CONFORM TO THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODE. 2. TEMPORARY SHORING CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE OF CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL -OSHA). 3. HEAVY CONSTRUCTION LOADS SUCH AS CRANES, CONCRETE TRUCKS OR OTHER LOAD SURCHARGES NOT IDENTIFIED IN THE 'DESIGN CRITERIA-, WILL REQUIRE ADDITIONAL ANALYSIS & FURTHER RECOMMENDATIONS. NOTIFY THE SHORING E SOILS ENGINEER. 4. ALL TEMPORARY SHORING ELEMENTS DEPICTED WITHIN THESE DRAWINGS ARE LIMITED TO A MAXIMUM SERVICE LIFE OF ONE (1) YEAR. AT THE END OF THE CONSTRUCTION PERIOD, THE EXISTING OR NEW STRUCTURES SHALL NOT RELY ON THE TEMPORARY SHORING FOR SUPPORT IN ANYWAY. 5. AN UNDERGROUND SERVICE ALERT MUST BE OBTAINED 2 DAYS BEFORE COMMENCING ANY EXCAVATION. 6. THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNERS AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS DURING CONSTRUCTION. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL INSPECTION SERVICES, TESTING Ft NOTIFICATIONS. B. ALL PERMITS SHALL BE PROCURED AND PAID FOR BY THE OWNER OR GENERAL CONTRACTOR. 9. ALL MONITORING PROVIDED IN THESE PLANS HEREIN, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. TEMPORARY SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING & PROPOSED FEATURES, AS PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL CONTROL & COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY VARIATIONS TO THE ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK. 11. THE GENERAL CONTRACTOR OR OWNER SHALL LOCATE ALL EXISTING UTILITIES AND STRUCTURES PRIOR TO EXCAVATION AND THE INSTALLATION OF SHORING. 12. THE GEOTECHNICAL ENGINEER OF RECORD SHALL REVIEW & VERIFY THAT THE PROPOSED TEMPORARY SHORING, CONFORMS TO THE SPECIFICATIONS OF THE APPROVED SOILS REPORT. 13. THE GENERAL CONTRACTOR SHALL CONFIRM THAT THE PROPOSED SHORING DOES NOT CONFLICT WITH FUTURE IMPROVEMENTS PRIOR TO INSTALLATION. 14. THE GENERAL CONTRACTOR SHALL PROVIDE MEANS TO PREVENT SURFACE WATER FROM ENTERING THE EXCAVATION OVER THE TOP OF SHORING BULKHEAD. 15. INSTALLATION OF SHORING AND EXCAVATION SHALL BE PERFORMED UNDER CONTINUOUS OBSERVATION AND APPROVAL OF THE GEOTECHNICAL ENGINEER AND AUTHORITY HAVING JURISDICTION. 16. ALTERNATIVE SHAPES, MATERIAL AND DETAILS CANNOT BE USED UNLESS REVIEWED AND APPROVED BY THE SHORING ENGINEER. 17. IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFY CONDITIONS AT THE JOB SITE AND TO CROSS-CHECK DETAILS AND DIMENSIONS WITHIN THE SHORING PLANS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER PERTINENT DRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. 18. ALL GRADING & EXCAVATIONS PERFORMED FOR THE PROPOSED TEMPORARY SHORING AND/OR PROPOSED STRUCTURE, IS OUTSIDE THE SCOPE OF SERVICES PROVIDED HEREIN. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONDUCTING SITE EARTHWORK IN CONFORMANCE WITH CAL -OSHA & GEOTECHNICAL RECOMMENDATIONS. SHORING INSTALLATION PROCEDURE 1. FIELD SURVEY DRILL HOLES & SHORING ALIGNMENT ACCORDING TO WALL DIMENSIONS & DATA SHOWN OR AS APPROVED BY THE SHORING ENGINEER. 2. DRILL VERTICAL SHAFTS TO THE EMBEDMENT DEPTH AND DIAMETERS SHOWN. ALLOWABLE PLACEMENT TOLERANCE SHALL BE Y' IN OR Y' OUT OR AS OTHERWISE AUTHORIZED BY THE SHORING ENGINEER. 3. INSTALL SOLDIER BEAMS ACCORDING TO THE DETAILS It SPECIFICATIONS SHOWN IN PLAN. IF NECESSARY, CASING OR OTHER METHODS SHALL BE USED TO PREVENT LOSS OF GROUND OR COLLAPSE OF THE HOLE. 4. START EXCAVATION AFTER CONCRETE HAS CURED FOR A MINIMUM OF (3) THREE DAYS. 5. INSTALL LAGGING BETWEEN INSTALLED SOLDIER BEAMS IN LIFTS NO GREATER THAN V-0" OR AS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. 6. BACKFILL ALL VOIDS BEHIND LAGGING LEAN CONCRETE AS SPECIFIED IN THE DETAILS HEREIN. 7. REPEAT STEPS 5-6 UNTIL BOTTOM OF EXCAVATION IS REACHED. 8. ALL EXCAVATIONS SHALL BE LAGGED AND BACKFILLED BY THE END OF EACH WORKDAY. NO EXCAVATIONS SHALL BE LEFT EXPOSED OR WITHOUT BACKFILL. NO. I DESCRIPTION I APPROVED I DATE I BENCHMARK MATERIAL SPECIFICATIONS STRUCTURAL STEEL 1. STRUCTURAL STEEL (WIDE FLANGES) SHALL CONFORM TO THE REQUIREMENTS ASTM A-572 OR ASTM A-992 (GRADE 50). 2. MISCELLANEOUS STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-36, ASTM A-572 (GRADE 50) OR ASTM A-992. 3. TRENCH PLATES (LAGGING) SHALL CONFORM TO THE REQUIREMENTS FO ASTM A-36. 4. WIRE ROPE (GUARDRAIL): SHALL HAVE A MINIMUM BREAKING STRENGTH OF 13,500LBS. STRUCTURAL It LEAN CONCRETE A. STRUCTURAL CONCRETE: 1. STRUCTURAL CONCRETE (DRILL SHAFT TOE BACKFILL) SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,50OPSI AT 28-DAYS. 2. CONCRETE MIX SHALL BE IN ACCORDANCE WITH 2O19CBC Ft ACI 318 TO MEET THE FOLLOWING: A. MAXIMUM 1 ANCH HARDROCK CONCRETE CONFORMING TO ASTM C-33. B. TYPE II/V NEAT PORTLAND CEMENT CONFORMING TO ASTM C-150. C. SLUMP NO GREATER THAN 5-INCHES. B. LEAN CONCRETE (SLURRY) 1. LEAN SAND SLURRY MIX SHALL CONTAIN A MINIMUM OF 1.5 SACKS TYPE II CEMENT PER CUBIC YARD. TIMBER 1. TIMBER LAGGING SHALL BE ROUGH SAWN DOUGLAS FIR LARCH NO. 2 OR BETTER. 2. TIMBER LAGGING SHALL BE PRESSURE TREATED FOR GROUND CONTACT IN ACCORDANCE WITH AWPA U1 USE CATEGORY 4A. WELDING 1. ELECTRIC ARC WELDING PERFORMED BY QUALIFIED WELDERS USING E70XX ELECTRODES OR CONTIUOUS WIRE FEED. 2. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. MONITORING 1. MONITORING SHALL BE ESTABLISHED AT THE TOP OF SOLDIER BEAMS SELECTED BY THE ONSITE GEOTECHNCIAL REPRESENTATIVE AND AT INTERVALS ALONG THE WALL AS CONSIDERED APPROPRIATE. 2. THE GENERAL CONTRACTOR SHALL PERFORM A PRECONSTRUCTION SURVEY INCLUDING PHOTOGRAPHS & VIDEO OF THE EXISTING SITE CONDITIONS. BASELINE SURVEY DATA TO BE SUBMITTED TO CITY LAND SURVEYOR. 3. MONITORING SHALL BE PERFORMED AFTER ROUGH GRADING, ANY SIGNIFICANT STORM OR SEISMIC EVENT AND AT THE TERMINUS OF THE PROJECT. FINAL MONITORING REPORT SHALL BE SUBMITTED TO CITY LAND SURVEYOR PRIOR TO OCCUPANCY. 4. MAXIMUM THEORETICAL SOLDIER BEAM DEFLECTION IS 2/3-INCH. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) EXCEEDS THIS LIMIT, ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED AND INVESTIGATED BY THE SHORING ENGINEER FOR FURTHER ACTIONS (AS NECESSARY). AS -BUILT APPROVALS ROY P REED DATE SENIOR ENGINEER DATE INT. PLANS PREPARED UNDER SUPERVISION OF Kt IBLIC BLIC WORKS DATE: PLANNING ST AK SEE RIGHT R.C.E. NO.: 80503 REVIEWER 7-20-21 I^o ROY P REED EXP.: 3/31/21 0A7r STATEMENT OF SPECIAL INSPECTIONS VERIFICATION AND INSPECTION CONTINOUS PERIODIC CBC REFERENCE 1. Verify use of required design mix X 1904.2.2 2. Inspection of concrete placement for X proper application techniques. 3. Material verification of structural steel a. For structural steel, identification X markings to conform to AISC 360. b. Manufacturer's report X 4. Inspection of welding a. Multipass fillet welds X 2303.1.8.1 5. Material identification of timber a. Identification of preservative X VERIFICATION AND INSPECTION ITEMS (OTHER) 6. Observe drilling operations and maintain complete and accurate X records for each element. 7. Verify placement locations and plumbness, confirm element diameters, lengths, embedment into X bedrock (if applicable). Record concrete and grout values. 8. Verify excavations are extended to the proper depth. X SPECIAL INSPECTION REPORT PREPARED BY: DATED . ON FILE WITH ENGINEERING DIVISION. DESIGN CRITERIA 1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED IN THE FOLLOWING GEOTECHNICAL REPORTS: A. PRELIMINARY GEOTECHNICAL INVESTIGATION PROPOSED NEW TWIN CONDOMINIUM UNITS 1739-1741 SAN ELIJO AVENUE ENCINITAS, CALIFORNIA PREPARED BY: ENGINEERING DESIGN GROUP, DATED 11-12-20. 2. SOIL DESIGN PRESSURES A. PASSIVE EARTH PRESSURE = 350PCF (7,000PSF MAX). B. ACTIVE EARTH PRESSURE = 35PSF/FT (CANTILEVERED) C. MINIMUM LIVE LOAD SURCHARGE = 72PSF UNIFORM D. BUILDING SURCHARGE = 700PLF LATERAL LINE LOAD SHORING DESIGN GROUP ppFESS/O�. C 80503 � C �P 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. APPROVED: SHORING PLAN FOR: -- 1739-1741 SAN ELIJO AVENUE LDEV-013341.2020 ILL T. BANKsroN LAU RA TAU BE R, LTR VENTURES INTERIM CITY ENGINEER 7/30121 APN: 260-275-28-00 DATE PUNNING CASE NO: 32H 2019 CDP SHEET 8 OF 8 PLEA 3106