Loading...
2020-14629 SG (Plans)OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DIVISION AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED "GEOTECHNICAL INVESTIGATION' PREPARED BY NOVA SERVICES, INC. DATED OCTOBER 10, 2019,PROJECT# 201969 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. SItY/3161ACIJq:l7,16-?.9G1:61:BM1*013fillCI4d&]:C1IR1019X911xH9:P]IC[r S. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING, 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOGAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION, 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN -AS GRADED CERTIFICATION' SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT NO: 14623G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADIN PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN'. THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATION$ ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT, DIRECT OR TEMPORARILY HALT GROUND -DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIVITIES ARE ALLOWED TO RESUME. NO.I DESCRIPTION I APPROVED I DATE 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE CORONER HAS MADE THE PUBLIC RESOURCES CODE EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND/OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU (-IN PLACE-), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT DAVID DEMIAN AT (8B) 245.2451. 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. B. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE DRIVEWAYS OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DE MPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3' CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE, ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION. AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ONSETE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS $HALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 4384151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. NOTIFICATIONS OLIVENHAIN MUNICIPAL WATER DISTRICT POTABLE WATER SYSTEM NOTES (CONT-D ON SHEET 2) 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES 1. POTABLE WATER WORKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE DETAILS AND EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE MATERIALS AS SPECIFIED IN THE MOST RECENT EDITION OF THE OLIVENHAIN MUNICIPAL WATER CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO DISTRICT (DISTRICT) STANDARD SPECIFICATIONS AND DRAWINGS FOR THE CONSTRUCTION OF WATER ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: MAINS AND FACILITIES, INCLUDING ALL AMENDMENTS ADOPTED PRIOR TO THE DISTRICT APPROVAL A. SEWERS-CTRIC-SSIXESD -GE6 DATE ON THESE PLANS. CONTRACTOR SHALL HAVE A COPY OF THE STANDARD SPECIFICATIONS ON B. GAS ELECTRIC - (760)430 386200 THE JOB SITE AT ALL TIMES. (SOGE E -6466 C. WATER-OMWD- (780)7538488 2. THE SUBMISSION AND REVIEW OF ALL SUBMITTALS (SHOP DRAWINGS, SIX SETS) AS REQUIRED BY D. TELEPHONE -SBC BELL- (760)-489-3411 THE STANDARD SPECIFICATIONS ARE TO BE ACCOMPLISHED PRIOR TO THE PRE -CONSTRUCTION E. CABLE TV- COX COMMUNICATIONS-(760}806-9809 X-2233 MEETING WITH THE DISTRICTS INSPECTOR. 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS 3. UNLESS OTHERWISE NOTED, CONNECTIONS TO EXISTING MAINS SHALL BE MADE DRY. THE TIME AND PROJECT. PHONE: (760)-633-2770. DURATION OF ANY SHUTDOWNS OF EXISTING MAINS SHALL BE SUBJECT TO APPROVAL BY THE 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633-2770. ALL WORK DISTRICT. DISTRICT SHALL BE NOTIFIED TWO WEEKS MINIMUM IN ADVANCE OF ANY SHUTDOWN. PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. 4. CONTRACTOR SHALL COORDINATE WITH DISTRICT ALL ARRANGEMENTS FOR HIGH -LINING EARTHWORK DATA TEMPORARY SERVICES PRIOR TO SHUTDOWNS. NO SHUTDOWNS WILL BE SCHEDULED ON A MONDAY STEEPEST EXISTING NATURAL SLOPE ONSITE= 4.5' H : T V OR FRIDAY. MAXIMUM VERTICAL DEPTH OF CUT= 4.3' MAXIMUM VERTICAL DEPTH OF FILL = 33' 5. CONTRACTOR SHALL REVIEW ALL PROPOSED TRENCH WORK WITH CAL/OSHA. A COPY OF EXEMPTION LETTER OR TRENCHING PERMIT, IF REQUIRED, SHALL BE SUBMITTED TO THE DISTRICT CUT= 81 C.V. FILL= 109 C.V. PRIOR TO CONSTRUCTION. IMPORT 228 C.V. REMEDIAL = 140 C.V. ( 1 REMOVAL AND RECOMPACTION UNDER AND 3 'OUTSIDE OF BUILDING AREAS) 6. WORK MAY BEGIN PROCEED WITHOUT DIRECTION DISTRICTS INSPECTOR. CONTRACTOR SHALL NOTIFY THE DISTRICT INSPECTIONS DEPARTMENT 488 HOURS PRIOR TO THE BEGINNING OF DISTURBED AREA= 438�SF WORK TO ARRANGE FOR INSPECTION OF THE PROJECT. IMPERVIOUS AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION: SOFT ABBREVIATIONS IMPERVIOUS AREA AFTER CONSTRUCTION: 1�00 SOFT INCREASE IN IMPERVIOUS AREA: 1,800 SOFT ADU ACCESSORY DWELLING UNIT FG FINISH GRADE P/L PROPERTY LINE BLDG BUILDING FS FINISH SURFACE PVC POLYVINYL CHLORIDE IMPERVIOUS AREA REPLACED: 40 SOFT OWNER DAVID S. DEMIAN S JESSICA M. DEMIAN 660 WINDMILL RANCH ROAD ENCINITAS, CA 92084-6558 SITE ADDRESS 660 WINDMILL RANCH ROAD ENCINITAS, CA 920846558 APN 264-172-37-00 PARCEL 1 TRACT 14488 OWNER'S CERTIFICATE VICINITY MAP V (WE) HEREBY CERTIFY THAT REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN WILLBE RETAINED TO SUPERVISE OVER AO GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. SIGNATVRE /y( DATE'✓/ /3O /Z V DEMIAN �/� 2 Z SIGNATURE �/ L DATE lV � �$ICA DEMIAN I, JOHN F. O'BRIEN A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON AND FOR AN UPDATE ON . ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. \ ( 7 SIGNED ,-,1pFE5 RCE NO 1 ^ � �� F. O'g�,p EXP. DATE: O 3-31-2021 JOB #: 2019189 COMPANY: NOVA SERVICES INC. ADDRESS: 4373 VIEWRIDGE AVENUE, Sw B SAN DIEGO, CA 92123 PHONE: 858-292-7575 4? _Q]FCN40CF STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS. TO THE EXTENT THAT THE ENGINEER NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. SIGNATURE: DATE: 5 20 0?A AS AGUILAR COMPANY: SAN DIEGUITO ENGINEERING ADDRESS: 462 STEVENS AVE. SUITE 306, SOLANABEACH CA92075 PHONE NUMBER: 85&345-1149 RCE EXPIRES 6-30-2021 I BMP PROJECT STATUS STANDARD BW BOTTOM OF WALL FL FLOW LINE R/W RIGHT OF WAY PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION OLIVENHAIN MUNICIPAL ENCINITAS FIRE DEPARTMENT C.O. CLEANOUT END FOUND SO STORM DRAIN WATER DISTRICT - D DEPTH IE INVERT ELEVATION SF SQUARE FEET Saud 71151120 DO DECOMPOSED GRANITE No. NUMBER TG TOP OF GRATE 7/15/20 14wmM EP EDGE OF PAVEMENT P PAD ELEVATION -7 � /` f7 { t 7191 TW TOP OF WALL TE S DATE SIGN DATE SIGN DATE SSITE SInGNw FF FINISH FLOOR PERF PERFORATED W WIDTH BENCHMARK AS -BUILT APPROVALS DesIGNEO e . DRAWNBY: 1 cHECKEO ev: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. AD im REVISE PAD SHEET 3 Qo 613o/zi INT. DATEI PLANS PREPARED UNDER SUPERVISION OF DATE:61D .207n R.C.E. NO.: 61158 RECOMMENDED: APPROVED: SNowO.k. �''•�'N/'•nr..ce STEVE NOWAK EDWARD J. WIMMER TITLE SHEET ACCESSORY DWELLING UNIT ADU DEMIAN RESIDENCE 14629• SG DESCRIPTION:ENCINITASCONTROLSTATIONENC-19 LOCATION: FD 2.5" CITY OF ENCINITAS BRASS DISC STAMPED"ENC-19' PUBLIC WORKS A,S.AGUILAR DATE PLANNING RECORD FROM: RECORD OFSM:NA -- �1 CITV13'1Z0 7/15/2020 7/IS/2020 660 WINDMILL RANCH ROAD REVIEWER D884I6 ELEVATION: 10]826 DATUM: NAVD88 A. S. AWILAR EXP.: 6-30-2021 0 DATE DATE PLANNING CASE NO: N/A 264-172-37-00 SHEET 1 OF 4 SENIOR ENGINEER DATE INSPrcma H U:IIDATA\ PROJECTS\5957 DEMIAN 660 WINDMILL RANCH RD\CAD FILES45857-GRAD61 TITLE.DWG EL CAMINO DEL NORTE EP—- EP— J (3) EXISTING WATER METERS PROTECT IN PLACE 190.53 N73 01' 18"W \ s SI so�sD�so� \ \ I I \ \ \ I I I \ \ \ \ I I ! I \ I I I I P r- I I i EXISTING DRIVEWAY I I � I _ i' � so,zi aw i I 83.00 BW i 60 8 (BF. __ IG\ 11 \TG/L I I 1 V I\ \ 1 Q 1 �, v1 \ \ 1 \ \\ (PROPOSED PAD Al \\ 1 (83.00) \ FG 83.00 BW/ / x I� �O S / APN 264-172-38-00 10 5 0 1D 20 SCALE: 1" = 1 V / /I / / I / YARD GRADING SCALE 1"=40' FOUND MAG I II II II APN 264-172-24-00 II I II I I w I 1 I 2� 1 1 I 1 1 I 1 1 EWER M.H. M=75.63 64.08' II II II I I I S I \\ FOUND MAG NAIL \ O1 EXISTING SAN DIEGO GAS AND ELECTRIC COMPANY EASEMENT PER F/P NO. 78-255931 RECORDED 6-20-70 OF O.R. EXISTING 20' PRIVATE ROAD AND UTILITY EASEMENT PER F/P NO. 77-435925 RECORDED 10-21-77 OF O.R. CONSTRUCTION NOTES O7 MASONRY RETAINING WALL PER SDRSD C-06 Q 12" X 12" BROOKS BOX SPECIAL NOTES 1. TW AND BIN GRADES REPRESENT THE GROUND ELEVATION AT THE BACK AND FRONT OF THE WALL THE ACTUAL TOP -OF -WALL AND TOP -OF -FOOTING AND WALL DIMENSIONS TO BE DETERMINED BY THE WALL DESIGNER. 91.57 EXISTING CITY STREET TREES FOUND 5/8- REBAR W/BKN CAP TO PROTECT IN PLACE, 6 PLACES — — — — — EL CAMINO DEL NOR—71- a _ ADU GRADING 190.5 SEE PLAN SHEEP 3 --- m i so_�� �r I YARD GRADING m o SEE PLAN THIS SHEET I 1 I T IO I' N o I zi n �m � Rl• � Rl• � I 'o - I ' ¢ n I 2AP 0, N Z IJ 2-172N37-00 YARD 20 I / 83.09 S4�3g�{_ �� R1• R1• R1• I R1• , FOUND 1/2' PIN W/CAP RCE24000 �O,S�-p�fpTliiS 75.53 7548 \FOUND MAG NAIL FOUND MAG SPIKE \ \ ao' so• � � I snr I s1mG*U I \ VACATED I VACATED I 7. THE CONTRACTOR MUST CALL "DIG ALERT OF SOUTHERN CALIFORNIA• TO HAVE UNDERGROUND SERVICE UTILITIES LOCATED PRIOR TO CONSTRUCTION. THIS CALL WILL BE MADE AT LEAST 48 HOURS IN ADVANCE PRIOR TO ANY WORK BEING PERFORMED IN PUBLIC RIGHT-OF-WAY. (DIG ALERT PHONE: 800-227-2600) S. ALL EXISTING FACILITIES WHICH MAY AFFECT PROJECT CONSTRUCTION, I.E., LINE CROSSINGS, LINE PARALLELING, OR PROPOSED CONNECTIONS SHALL BE FIELD VERIFIED BEFORE ANY CONSTRUCTION BEGINS. 9. THE CONTRACTOR SHALL FURNISH AND INSTALL PER THE STANDARD SPECIFICATIONS THE APPROPRIATE BURIED UTILITY WARNING AND IDENTIFICATION TAPE ABOVE ALL PUBLIC WATER LINES INCLUDING WATER LATERALS LOCATED IN PUBLIC RIGHT-0E-WAY. 10. WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE PROFILE IS 48-INCHES BELOW CENTERLINE OF FINISH GRADE OF STREET. 11, ALL DEFLECTIONS (HORIZONTAL AND VERTICAL) SHALL BE MADE BY USE OF JOINT COUPLINGS WITH 4° MAXIMUM DEFLECTION PER COUPLING (2- PER JOINT). NO BENDING (CURVING) OF PIPE SHALL BE PERMITTED. 12. MANUAL AIR RELEASES SHALL BE INSTALLED AT ALL HIGH POINTS AND BLOW -OFFS AT ALL LOW POINTS IN THE WATER MAIN PROFILE. PLACE MANUAL AIR RELEASE$ AND BLOW -OFFS WITHIN METER BOX AND LOCATE BEHIND CURB UNLESS OTHERWISE APPROVED BY DISTRICTS REPRESENTATIVE. FIRE HYDRANTS MAY BE USED IN LIEU OF A MANUAL AIR RELEASE OR BLOW -OFF WHEN LOCATED AT OR NEAR HIGH OR LOW POINTS, AS APPROVED BY THE DISTRICTS REPRESENTATIVE. 13. INSTALL A MINIMUM 1-INCH WATER SERVICE TO EACH LOT. METER TO BE LOCATED S-FEET FROM A SIDE LOT LINE. A 3/41NCH HIGH LETTER •W" SHALL BE CHISELED IN TOP OF EXISTING CURB OR IMPRINTED IN NEW CURB AT ALL WATER SERVICE CROSSINGS. 14. METER BOXES SHALL NOT BE PLACED WITHIN DRIVEWAYS OR SIDEWALKS WITHOUT THE DISTRICTS PRIOR WRITTEN CONSENT. 15. ALL WATER SERVICES FOR IRRIGATION, MULTIPLE RESIDENTIAL COMPLEXES, COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL HAVE APPROVED BACKFLOW PREVENTION DEVICE ON CUSTOMER'S SIDE OF WATER METER, 16. CONTRACTOR SHALL TIE OFF ALL VALVE LOCATIONS AND PROVIDE WRITTEN DIMENSIONS TO INSPECTOR IMMEDIATELY UPON INSTALLATION OF VALVES. 17. LINE VALVES, WHERE REQUIRED AT STREET INTERSECTIONS SHALL BE LOCATED AT THE TEE WHENEVER POSSIBLE. 18. FIRE HYDRANTS, AS APPROVED BY THE APPROPRIATE FIRE DISTRICT AND MEETING THE DISTRICTS STANDARD SPECIFICATIONS, ARE TO BE INSTALLED AT LOCATIONS SPECIFIED BY THE FIRE DISTRICT. 19. ALL DESIGN CHANGES TO THE WATER SYSTEM SHALL BE APPROVED BY THE DISTRICT REPRESENTATIVE IN WRITING PRIOR TO CONSTRUCTION AND ACCEPTANCE OF THE CHANGE. 20. THE WATER SYSTEM SHALL BE PRESSURE TESTED IN ACCORDANCE WITH THE PROCEDURES IN THE OMWD STANDARD SPECIFICATIONS. THE CLASS OF PIPE SHALL BE USED AS THE DESIGNATED WORKING PRESSURE FOR TESTING ALL PIPE, VALVES (CLOSED) AND APPURTENANCES. 21. PIPELINES AND APPURTENANCES SHALL BE DISINFECTED IN ACCORDANCE WITH SECTION 1SIN 1 OF THE OMWD STANDARD SPECIFICATIONS PRIOR TO TIE-IN OR CONNECTION TO EXISTING SYSTEM FACILITIES. BACTERIOLOGIC QUALITY TEST RESULTS SHALL CONFORM TO THE CRITERIA SPECIFIED IN THAT SPECIFICATION. 22. CONTRACT RECORD DRAWINGS MUST BE SUBMITTED PRIOR TO FINAL ACCEPTANCE OF WORK. THE PLANS MUST PROVIDE POST CONSTRUCTION VERIFICATION OF THE LOCATION AND ELEVATION OF PIPES AND APPURTENANCES. 23. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF ACCEPTANCE FOR THE PROJECT. CONTRACTOR SHALL REPAIR OR REPLACE ANY OR ALL SUCH WORK, TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN SO DOING THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND/OR MATERIALS WITHIN THE ONE-YEAR PERIOD FROM THE DATE OF ACCEPTANCE WITHOUT EXPENSE WHATSOEVER TO THE DISTRICT, ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT EXCEPTED. 24. ALL IRRIGATION METERS SHALL BE SERVED WITH RECYCLED WATER UNLESS PREVIOUSLY APPROVED IN WRITING BY THE DISTRICT 25. ALL BURIED FITTINGS AND VALVES SHALL BE WAX TAPE WRAPPED IN ACCORDANCE WITH OMWD STANDARD SPECIFICATIONS. SITE PLAN _ SCALE 1"-40' LOT AREA: 27,442 SF ZONING: R-1 : SINGLE LAND USE: SFR FLOOR AREA OF PRIMARY RESIDENCE: 2,201 SF CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: ro ID.w2� R.C.E. NO.: 81158 d X% 'A. S. ACI EXP.: 6-30-2021 RECOMMENDED: APPROVED: S ,�NQ,,, f�d„„„,e s. N/.,,,,,,,�,, STEVE NOWAK EDWARD J. WIMMER CITY ENGINEER 7/35/2020 7//$/2020 DATE GATE SITE PLAN PLAN FOR: ACCESSORY DWELLING UNIT ADU 1 DEMIAN RESIDENCE 660 WINDMILL RANCH ROAD PLANNING CASE NO: N/A 264-172-37-00 14629•SG SHEET 2 OF 4 DESCRIPTION: ENCINITASCONTROLSTATION ENC-19 LOCATION: FD 2.5" CITY OF ENCINITAS BRASS DISC STAMPED"ENCSTAMPED'ENL1� RECORD FROM: RECORD OF SURVEY N0.18416 ELEVATION: 10]826 DATUM: NAVD88 PUBLIC WORKS A. S. AGUILAR DATE PLANNING REVIEWER SENIOR ENGINEER DATE iMsurcma u U:IIDATA\ PROJECTS\5957 DEMIAN 660 WINDMILL RANCH RD\CAD FILESM57-GRAD-02 SITE PLANOWG �.-6" PVC RISER WITH DOME GRATE 70" *ENGINEERED SOIL NOTE: LAYER SHALL BE I8. DEEP AND SHALL HAVE VOLUME AND WEIGHT 3" WELL -AGED, SHREDDED AS FOLLOWS (PER COSD UD MANUAL G.1.1) AND MINIMUM INFILTRATION RATE OF 5.0 IN/HR.: �\ 6" T % HARDWOOD MULCH 5 11 --BOTTOM SURFACE AREA = 50 SFj 18" ENGINEERED SOIL, *SEE NOTE 1-I F-I I- L III III BELOW - 1 1Hll-L1=-11-iL f H 12" (3/4" ) CRUSHED ROCK IMPERMEABLE LINER GRAVEL LAYER ABOVE INVERT SOIL SANDY LOAM SAND SAND SILT CLAY COMPOST VOLUME 55% 20K 15% WEIGHT 75-80% 10% MAX 3% MAX 9% MAX OF PERFORATED PIPE ' "12" CRUSHED ROCK LAYER. CL. II PERMEABLE ROCK WITH MIN. 40% POROSITY PER **SEE NOTE BELOW CALTRANS SPEC 68-202F(3). 6" DISCHARGE PIPE- NUTRIENT SENSITIVE MEDIA NOTE: ALL MEDIA SHALL COMPLY WITH THE NUTRIENT 3" (3/4" )CRUUSHED ROCK GRAVEL DYER- 6SENSITIVE MEDIA PER BF-2. BELOW INVERT S PERFORATED PIPE `- * PERFORATED PVC PIPE W/ PERFORATIONS 0 BIOFILTRATION DETAIL *SEE NOTE BELOW INVERT ALONG LENGTH OF BASIN 4 0.5% SLOPE NOT TO SCALE _- _ _ �R/W-� ' I 1 117 __---___ __ _1 1 -L__ 1 \ \ I 1 1 I EXISTING CITY sTR,EET TREES -TO PROTECT IN PLACE , / FOLNO .516' REBAR JIj9KN CLAP PROTECT, MONUMENT IN PLACE f EL CAM�NO DEL'_NORTE m 1 1 I - p mm 71 91.49' m u nm 4 1�L/HP n 1 as _- a o - m m RIP -RAP to N i (91.50) m(91.13) 2 "(90_35) 3 _ _ (88.72)mm(68.33) mm8B.15. 66.15 N0.2 BACKING . - �'. FG ; �� FG�, FG FS FL \ �- 51 X 3'W X VU 91.65 TW 85.94 BW 90.31 TW \-87-00. 5 ri Gm) 8641 a 8q 87.46 8g4- .�p a 85, 4 8F.C9l�•84 TW \ 4J, - .FS/ _ 85.9C IE FIG UW I • tl5.94 IG /• - .•' 85.73 TO IE 5 f i , _ / i 1.,. 85,1 4 85.94 T61 2• TO / PROPOSED ADU _: _ -8C90-iG !'-'�G, �.- 85.40 IE 86. <... ,/8s.86 q' ff=87-.ff FF=86.61 / TW �! 85.90 IE i P-89:9B P=85.94 I 6. 8 B 1 !`. i 8A.f BIN V I aT FS 4 PVC _ - 1 - I 84.90 E. && 86.41 86.33 1l �4• 85.90 TO i• FS- 48.G43 �85.94 ,. % IE .711+ �,/ 86 4fi, 8g '@Y-7-�A _ FS. ,�� MIA 0 58.94 Y 66.2_5 •� L C FG / es4 i FG 51.775 IE SPECIAL NOTES 1. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN ALL DRAINAGE SYSTEMS FREE AND CLEAR OF ALL OBSTRUCTIONS IN ORDER TO ASSURE PROPER OPERATION. 2. TW AND SW GRADES REPRESENT THE GROUND ELEVATION AT THE BACK AND FRONT OF THE WALL THE ACTUAL TOP -OF -WALL AND TOP -OF -FOOTING AND WALL DIMENSIONS TO BE DETERMINED BY THE WALL DESIGNER. 3. ROOF GLITTERS REQUIRED FOR ALL SECOND STORY OVERHANGS. 4. THE LOCATION OF INDIVIDUAL UNDERGROUND UTILITY SERVICES. PRIVATE SEWAGE DISPOSAL SYSTEMS, IRRIGATION SYSTEMS AND SATELLITE CABLE TV SERVICES IS NOT KNOWN. THIS INCLUDES BUT IS NOT LIMITED TO, ELECTRIC SERVICE UNES, GAS TANKS, OAS SERVICE DIVES, TELEPHONE SERVICE UNES, WATER SERVICE UNES, GABLE TV LINES, SEPTIC TANKS, LEACH UNES, TIGHT UNES. SEEPAGE PITS. IRRIGATION LINES. SPRINKLERS, VALVES, AND SATELLITE TV CABLE THE CONTRACTOR WILL PERFORM THE NECESSARY RESEARCH, MAKE EXPLORATORY EXCAVATIONS AND/OR LOCATE THESE SYSTEMS/SERVICES SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING SYSTETJS/SERVIOES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT THESE SERVICES AS PART OF HIS WORK. 5. EARTHWORK QUANTITIES FOR PERMIT PURP05ES ONLY. CONTRACTOR TO CALCULATE ALL QUANTITIES. �✓ I 58428 0 S.F. y 1, �sa� 85.47 7 6" PERT. pIPE" 6.31 Bw' IE +^.e i lJ 85.40 8532 G \ I I! FC FG 2 85.35 FG ,\-RIP RAP 87.80 TW FG_ A � � � NO. 2 BACKING gy 85.13ew I 3'L X 3W X i'D - I-PCC HEADWALL 15" WIDE X 6" THICK o-�s�ss-ss-a=T + EXISTINGPAVEME 5.0 .+ 633 /-' .wrote an rrarw= W W 6�` 65.10 IE EXISTING DRIVEWAY -a-;..G-y, III" 4.: PD� I F5 _ - _ W� "� FIG r FG2y - 87r'66 TN 88.32i FL RIP -RAP r o' NO. 2 BACKING m 5'L X VW X 1�`D 1 5' ADU AD SETBACK lI 'FS/�'''� - 87.80 TV 84.94 BW I \' ` `� gl I'� f 80 s2 BIN \\ 97.ao Tw vl 84.89 84.93 BW �L b , FS STARS 86 53 TWL 84.92 ({)-7�M,}X- '1 _ (84.86) RISERS DGI (PATH LL I[;8 `IFS s �`... (8 \1 FS aa.7e F r EXISTING I R°f PAVFUFNT _ 1 `j86.53 TW (84.63) FS EXISTING RESIDENCE ACCESSORY DWELLING UNIT GRADING SCALE: 1 *m5' J - 0 5 2.5 0 5 SCALE: 1" =5' 10 M \ 1 1 1 1 1 1 1 1 I I PROPOSED WATER AND SEWER CONNECTIONS BY OTHERS LEGEND AREA DRAW W/PVC PIPE-so--("rso- RETAINING WALL (SIZE PER PUN) 12" X 12" BROOKS BOX ® CONCRETE SWALE SWALE DIRECTION DO PATH SLOPE TOP h TOE _ y _ F _ EXISTING CONTOURS CONCRETE PROPOSED CONTOURS 200 - RIP RAP SPOT ELEVATION 94.8 LIMIT OF GRADING 1 BUILDING SETBACK - - - 4"-6* PVC STORM DRAIN sc / EXISTING EDGE OF PAVEMENT rF PCC HEADWALL, 18"W K 6"T PROPERTY UNE CONSTRUCTION NOTES CONCRETE SIDEWALK Q MASONRY RETAINING WALL PER SDRSO C-03 O3 BROW DITCH (TYPE B) PER SDRSD D-75 O4 NOT USED O 6" PVC STORM DRAIN CLEAN OUT O 6" PVC STORM DRAIN RISER O9 REMOVE EXISTING ONSITE TREES AS NEEDED AND DIRECTED BY CONTRACTOR AND OWNER. -? `'D��.F-RIP-RAP 1 \ \ \ �\. NO. 2 BACKING V' PCC HEADWALL\ \ 10'L X 5'W X 1'D I8* WIDE X 6* THICK \\ \\ 1 I 1 \ \ \ V It I I \ \ \ I I \ \ \ I II \\ \ \ 1 IT wi WSTiNG DRIVEWAY \\ \\ I I 1 \ I J \ I I 1 aft1 CHANGE NO. I DESCRIPTION APPRovEo I DATE I BENCHMARK LOCATION. FD:2.5"CFNCINOFENUNITASTROL ATIGND11 ]R LOCATION: STAMPDI EN CNGNRAa BRAs5 DISC STAMPED`ENC-19" RECORD FROM: RECORD OF SURVEY NO. 18418 ELEVATION: 107826 DATUM: NAVD88 AS -BUILT APPROVALS INT, DATE PUBLIOWORKS ENGINEERING DIVISION APPROVALS RECOMMENDED: APPROVED: O TINEA NOWLLIo E.ARDJt WIMM.`*..,�" STEVENOWAK EDWARDJ. WIMMER CITY 7' ENGINEER %/1.5/202D 7//$/-0- j�� DAB CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT ADU GRADING PLAN ACCESSORY DWELLING UNIT (ADU) DEMIAN RESIDENCE 660 WINDMILL RANCH ROAD PLANNING CASE NO: N!A 264-172-37-00 DRAWING NO. 14629•$(a' 1p."- b"g?'=''��""'"`"" PLANS PREPARED UNDER SUPERVISION OF DATEL10.1020 - '� 1 R.C.E. NO.: 81158 C x�'� .0. 5. nGLiILMR EXP.: 6-30-2027 m REVISED PAD WALLS AND ELEVATIONS 110 6/�/a! A. S. AGUILAR DATE PLANNING REVIEWER SENIOR ENGINEER DATE INSPECTOR SHEET 3 OF 4 z'6 �w� Znmm 0 0 4< zw U� w>X 2 DIM, 0 33w z 70 w wM UAl OATAl PROJECT515857 OEMAN 660 WINDMILL RANCH RDICAD FILE515B57•GRAD-03 GRADING PLAN. DWG LEGEND PUBLIC TRAVELED WAY CONTRACTOR IS RESPONSIBLE TO ENSURE SHEET FLOW IS MNNTANED ACROSS FLOW BARRIERS 1I SET STAKES AND EXCAVATE SWALE DIRECTION �-�-- 'IIIN. —� 1 1jj7 �L 6 ByA 6 IN (15 BY 5 cm) _ _ _ r A TRENCH LFROM AND SLOPE TOP @TOE _ _ y _ HYDROSEEDING ALONG THEE LINE OF STAKES. L — — J 8" MIN. GRAVEL BAGS OVERLAP EXISTING CONTOURS 200 ® 1 PROFIL ONTO CURB PROPOSED CONTOURS — 200 — GRAVEL AND SAND BAGS /co SILT FENCE—9F—BF— EXISTING GROUND �� 6 IN (15 CM) m PUBLIC VELED WAY CD BUILDING SETBACK 2. ATTACH THE FILTER FABRIC TO THE WOOD J. B4CKFlLL AND COMPACT THE MATERIAL DELIVERY AND WM-1 ♦ STAKES AND EXTEND IT A MIN. OF 6" DEEP EXCAVATED SOIL. EXISTING EDGE OF PAVEMENT EP STORAGE AREA ��� AND 6" ACROSS THE BOTTOM OF THE TRENCH. PROPERTY LINE WM-5 WMIN. 3 FT (0.9 M) MIN. SOLID WASTE MANAGEMENT 0 �� 8" D14. FIBER WOOD ROLLS, EMBm IN LIMIT OF GRADING HAZARDOUS WASTE MANAGEMENT WM-6 PLC RUNOFF FILTER FABRIC T STAKE VAR/gg� SLOPE�� SOILCASSE-5 TE - PER SANITARY WASTE MANAGMEM WM-9 PROVIDE APPROPRIA TRANSITION BETWEEN STABILIZED CONSTRUC17ON GAP BETWEEN BAGS THREE LAYERS OF GRAVEL BAGS ENTRANCE AND PUBLIC TRAVELED WAY. ACTS AS SPILLWAY WITH ENDS OVERLAPPED 3/4" X SPACING, IBWOOD STAKES, MAX CONCRETE WASTE MANAGEMENT WM-B FIBER ROLL, PER CASOASE0~ 5 QA STABILIZED CONSTRUCTION ENTRANCE ® GRAVEL BAGS Q SILT FENCE Q FIBER ROLL -- \ EL CAM�NO DELI E — - 91.57 � FOUND 5/8" REBAR W/BEN CAP 15 / Y / \ 3's0� �I � /' I �_ I _��• s s I I v y 4 / \A / /0¢ WM-1 WM-5 WM-9 WM-3 WM-6 WM-8 II \\\ \\\ \\\ \\\ ,+f 9 q —SD su �. / \� \I II. CEP .< I 4R 3.5' IEa I \ \ y I T I \ III 11 I 1 \\ SF—SFI— S1—SF�-� � W 1 I / \ I / I\ \ \\ I 1 I \ / I \ IW LL I / / I O P P I `.J w w^ wt:AY 'NO. 61158 w i / /' i _/ ACCESSORY DWELLING UNIT EROSION CONTROL 5 2.5 D 5 10 p�< z ob / SCALE: I"I 4e CALAf� o w < w ww¢ / SCALE: 1" = 5' i- z So Ewa CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DesIGNED Bv: DRAWN ev: CHECJITKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRINT. DATE PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APPROVED: ADD EROSION CONTROL PLAN LOCATION: TION ACCESSORY DWELLING UNIT ADU LOCATION: FD 2.5"CffYOFENONRASBM56 DISC PUBLIC WORKS DATE: SiPNPr NOWCiIG fd«..d f{. %V'M�A STAMPED"ENC-19" A.S.AGUILAR DATE J.DEMIAN RESIDENCE 14629• SG PLANNING p'-� STEVE NOWAK CITY EN INFER ER RECORD FROM: RECORD OF SURVEY VD88 16 4 r _ .(? R.C.E. NO.: 81158 CITY ENGINEER ELEVATION: 10]826 DATUM: NAVD88 REVIEWER �JL-� 30'ti 7/35/2020 7//$/2020 660 WINDMILL RANCH ROAD SENIOR ENGINEER DATE INSPECTOR 'A' 8. AWUPIR EXP.: 6-30-2021 DATE DATE PLANNING CASE NO: N/A 264-172-37-00 SHEET 4 OF 4 U:IIDATA\ PROJECTSI5857 DEMIAN 660 WINDMILL RANCH RD\CAD FILESM57-GRAD-04 EROSION CONTROL PLAN.DWG