Loading...
2018-14083-G (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBUC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBIUTY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UT= NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE. PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED "PRELIMINARY GEOTECHNICAL EXPLORATION ENCINITAS RESORT HOTEL" PREPARED BY LEIGHTON GROUP DATED 04/04/12. AND UPDATE DATED 08/02/2017. PROJECT# 11574.001 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. SEE GEOTECHNICAL RENEW LETTER PREPARED BY LEIGHTON GROUP DATED JANUARY 4, 2019 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION 'NTH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5, CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS. LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE PATH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR. CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED PATH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAUUNG DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT 14083-G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED. GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE :FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE UABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANYSUCHMATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITYS URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT. SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT NTH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL, NO. I DESCRIPTION I APPROVED I DATE PLANS FOR THE CONSTRUCTION OF ENCINITAS BEACH RESORT PRECISE GRADING IN THE CITY OF ENCINITAS KEY MAP LEGEND PROPERTY LINE _R _ RIGHT-OF-WAY. -R/W- SHEET INDEX. ... BC .............. BEGINNING OF CURVE EC .............. END OF CURVE EP.............. EDGE OF PAVEMENT TC.............. TOP OF CURVE FL_ ........... FLOW LINE FS... I ... ....... FINISH SURFACE FG.............. FINISH GROUND FF.. ............ FINISH FLOOR GB .............. GRADE BREAK TF.............. TOP OF FOOTING TW............. TOP OF WALL SD CB....... STORM DRAIN CATCH BASIN SO CO.-.... STORM DRAIN CLEANOUT GR............. GRATE ELEVATION IE.............. INVERT ELEVATION TOP........... TOP OF PIPE 'S STATEMENT FOR SWPPP PROJECTS IN THE CASE IN WHICH A PROJECT PROPOSES LAND DISTURBANCE OF ONE ACRE OR MORE, AN ADDITIONAL CERTIFICATION WILL BE REQUIRED. THE OWNER/DEVELOPER SHALL EXECUTE THE STATEMENT BELOW. DEVELOPMENT OF THIS PRODUCT SHALL COMPLY WITH ALL THE REQUIREMENTS OF THE MOST RECENT STATE WATER RESOURCES CONTROL BOARD (SWRCB) ORDER, WASTE WATER DISCHARGE REQUIREMENTS FOR DISCHARGES OF STORMWATER RUNOFF ASSOCIATED WITH CONSTRUCTION ACTIVITY. IN ACCORDANCE WITH SAID PERMIT, A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) AND A MONITORING PROGRAM PLAN SHALL BE DEVELOPED AND IMPLEMENTED CONCURRENT WITH THE COMMENCEMENT OF GRADING ACTIVITIES, AND A COMPLETE AND ACCURATE NOTICE OF INTENT (NOI) SHALL BE FILED WITH THE SWRCB. A COPY OF THIS PROJECT SWPPP SHALL BE FILED WITH THE CITY OF ENCINITAS; FURTHER, A COPY OF THE COMPLETED N01 FROM THE SWRCB SHOWING THE PERMIT NUMBER FOR THIS PROJECT SHALL BE FILED WITH THE CITY OF ENCINITAS WHEN RECEIVED. IN ADDITION, AND SUBSEQUENT OWNER(S) OF ANY PORTION OF THE PROPERTY COVERED BY THIS GRADING PLAN NO. 6394-G AND BY SWRCB NO. R9-2015-0001 AND ANY SUBSEQUENT AMENDMENTS THERETO SHALL COMPLY WITH THE SPECIAL PROVISION AS SET FORTH IN SECTION C.7 OF SWRCB NO. R9-2015-0001. NO 'Lo 37C384!k 7(\ O _JJ DA ENCINITAS BEACH HOTEL VENTURE LLC OWNER'S CERTIFICATE I HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I HEREBY AGREE TO INDEMNIFY DEFEND AND HOLD CITY AND GTYS OFFICERS OFFICIALS EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL UABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS,. SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PL&NS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS, SIGNATURE: DATE: XIL4110, E ITAS BE HOTEL VENTURE, LLC SOILS ENGINEER'S CERTIFICATE I, WIWAM D. OLSON A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR WWI I - V V V RECOMMENDATIONS, HASBEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. SIGNED: �D• ��`�' 3zj19 L U WASTEWATER PE 45283 WILUAM D. OLSON DISTRICT SIGNED: R• 'a•J, ` RwA 3 I h9 - PUBLIC SEWER SYSTEM APPROVAL CEG 2099 ROBERT C. STROH _ 9PLj&QV® BY: LOUD DISTRICT ENGINEER LEIGHTON CONSULTING INC. -lll��X1]Y.CX/C)/1IVl1 C336921'`'Z-� 3934 MURPHY CANYON ROAD, SUITE B-205 DES. CSON, P.E. RCE DATE SAN DIEGO, CA 92123 (858) 292-8030 DEXTER WILSON ENGINEERING, INC 6/30/2020 FIRM EXP. DATE SCALE T SCALE 1" = 100' NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE -PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES -TO PROTECT ANY EXISTING UTIUTIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - CSD/ESD - (760)-633-2770 LWD 760-753-0155 B. GAS & ELECTRIC - SDGE - (760)-438-6200 C. WATER - SAN DIEGUITO WATER DISTRICT-1-800-227-2600 D. TELEPHONE - SBC BELL - (760)-489-3411 E. CABLE TV - COX COMMUNICATIONS-(760)-806-9809 X-2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)-633-2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633-2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 13,939 SOFT IMPERVIOUS AREA AFTER CONSTRUCTION: 112,550 SOFT INCREASE IN IMPERVIOUS AREA: 98,611 SOFT IMPERVIOUS AREA REPLACED: 13939 SOFT STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFIGENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON, THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED. BY THE ENGINEER. SIGNATURE: ;�_ DATE: ac MA K L. HENNING, R.C.E. 58007 HALE gSVpGA,O0 pT C,s sxeixeexANDHALE ENGINEERING ANDSURVEYING, INC. 7970 CONVOY CT.i1*2 EN6INEERINO SAN DIEGO, CA 92111 (858) 715-1420 lP TT` P PUBLIC WORKS P NG AND BUILDING P r r r •r r I" h I CLINTON E. HALE DATE RICE. NO.: 58007 VERTICAL NA r I L_ .: n :: �a�m�a:amLi�r.�raaeyyalr•TernreVllaa:a v. r r LEGEND IMPROVEMENT STD, DRAWING NO. SYMBOL PROPERTY LINE ........................... _ _-R- RIGHT-OF-WAY. ..... . _ .... .... -R/W- EXISTING CONTOUR ..... ... PROPOSED CONTOUR......1 11.....1 .... LIMIT OF GRADING/DAYLIGHT LINE. .... . .................. - - SLOPE (CUT 1:1 MAX, FILL 2>1 MAX) . . ................... . GRADE BREAK LINE .................. ................. PROPOSED BUILDING OUTLINE. ................... PROPOSED DECORATIVE 6" VEHICULAR I.e PEDESTRIAN _ P.C.C. CONCRETE PER GE07ECH REPORT AND LANDSCAPE PLANS FOR FINISH AND COLOR PROPOSED AC OVERLAY (T=1.5"). ....... I .......... {{���'77cC�-'��..,, FlXY�I1�YiL5(� PROPOSED REMOVED AND REPLACE AC PAVEMENT. .(4" AC/4". BASE).. PROPOSED PRECAST TRUNCATED DOME PAVERS S.D.R.S. DWG. G-3.0 ONYX OR DOME ACKERSTONE' CAST TRUNCATED APPROV, EQUIV,. _ . "°�°"°"°"°•°°�"°"°°"°"°"°"°"°"° PROPOSED 6" PCC CURB. ... ..- SOR.S. DWG. G-1 PROPOSED RETAINING WALL . ........... . ............. . PERMANENT SHORING PER ROUGH GRADING PLANS PROPOSED MODIFIED PCC BROW PER MODIFIED TYPE IS BRDW, DITCH DETAIL, SHEET 2 '0' DITCH TYPE WIDTH = 1FT PROPOSED SD CLEANOUT. ....... PER SD CLEANOUT DETAIL, SHEET 2 PROPOSED 18"X18" SD GRATE. . ,PER CATCH BASIN DETAIL, SHEET 2 PROPOSED STORM DRAIN - CABLE VEHICULAR/PEDESTRIAN BARRIER. ... PER LANDSCAPE PLANS. EXISTING 0-3 INLET STRUCTURE . ............... ......... �TP� EXISTING CURB INLET TYPE 'B'....... EXISTING STORM DRAIN CLEANOUT TYPE •A-4'..........._- EXISTING STORM DRAIN . ............. ............ - - - - EXISITNG WATER MAIN ................................. -W W- EXISTING SEWER MAIN _ _ _ ___ _ _ _ _ _ _ ___ ...... _ . _ -S S- EXISTING ELECTRICAL ONE .................. -E E- FINISHED GRADE ELEVATION ............. . ....... ✓ 4 FG 44.8 EXISTING GRADE ELEVATION.. .. . ........... F L 44.83 FLOW LINE ELEVATION. ....................... . ......... FS 44.83�µ�83g� FINISH SURFACE ELEVATION. ...... ... _ _ FINISH FLOOR ELEVATION . .. ...... ...... ........ �p TEE y;.3 TOP OF CURB ELEVATION . ....................... EDGE OF PAVEMENT ELEVATION. . TOP OF CURB FOOTING. TOP OF CURB WALL ... INVERT ELEVATION .... ... ..... ......... 44.83 TI��4q�g� TOP OF PIPE ELEVATION ............................ ✓TOP GRATE ELEVATION . .................... .............. ✓ SHEET INDEX SHEET 1 ................ I....... TITLE SHEET SHEET 2 ................ ... ... I. NOTES AND DETAILS SHEET 3-11 ........................ PRECISE GRADING PLAN SHEET 12-13 ..............._ ..... PRECISE GRADING CROSS-SECTION SHEET 14-19 ........................ RETAINING WALL PROFILES SHEET 20-23 ....................... RETAINING WALL STRUCTURAL NOTES AND DETAILS SHEET 24-25 ........................ EROSION CONTROL EARTHWORK `CUT=5,540 CY FILL-15,960 CY IMPORT-10,420 CY ENCINITAS BEACH HOTEL VENTURE, LLC 12250 EL CAMINO REAL, SUITE 160 SAN DIEGO. CA 92130 PHONE: 858-350-4800 0 u+. BATIQUITOS LAGOON 5 E PROJECT d z a NRfW P w W O IAA J � YLL 2 i d N SITE ADDRESS VICINITY MAP 2100 NORTH COAST HIGHWAY N.T.S. ENCINITAS, CA BMP PROJECT STATUS ASSESSOR'S PARCEL NUMBER 216-041-26-00 PRIORITY STORMWATER LEGAL DESCRIPTION 3Y OWNER IN ACCORD, PRIVATE STORMWATER PARCEL 1 OF PARCEL MAP NO. 18587 IN THE CITY OF ENCINITAS COUNTY OF SAN DIEGO STATE OF FACIUTIES TO BE MAINTAINED CALIFORNIA, ACCORDING TO THE MAP THEREOF, RECORDED ON RECORDED NOVEMBER 21, 2000 AS FILE NO. _0117081 2000-0635224, FILED IN THE OFFICE OF THE AS DOC. $: COUNTY RECORDER OF SAN DIEGO COUNTY. ARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT W17-030 DIVISION APPROVALS APP OVED EDWA J MME DATE SIGN DATE CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT I DRAWING NO. ENCINITAS BEACH RESORT PRECISE GRADING APN: 216-041-26 -014 18-257 SURC 14083-G M F�c U„ LDEV-011233-2018 EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REWIRED, CONTACT DREW PETERSON AT (619) 571-6054. 24 HQURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON0CTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACIUTATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL R THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION R THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REWIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION R UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAM AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION R FACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE M PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL STORMWATER POLLUTION CONTROL BLIP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE VA2HDM CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM R ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. WNSTROCTNRI SR'6 ACCESS; A STABIUZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE THIS SHALL INCLUDE USING MATERIAL SUCH AS Y CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CMMTRUCMCM AA SPECIFICNAARREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. SON CON110N, EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES R SHRUBS UNNECESSARILY: THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PUNTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIED AND BIND THE SOIL PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON-= CCONSTRUCM N► MM STORAGE I STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WLL STAY DRY OUT F THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. EUMMATE R REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL HE COVERED OR PROTECTED WTH SOIL STABILIZATION MEASURES AND PROVIDED WTH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. 7RAOIRTO CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY R ENCINITAS SHALL BE TRAINED TO BE FAMILIAR NTH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THOR OWN RESPONSIBILITIES. CONTRACTOR BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATEMAL4. DUMPING OF UNUSED R WASTE PRODUCTS ON THE GROUND. WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES NTH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WTH ANY TRASH MATERIAL MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL R DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL I AT (760) 436-4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTR, AND STORMORAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY R ENCINITAS AT (760) 633-2770. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BLIP/DIIP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF RAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WTHOUT A PERMIT FROM THE CITY, SAN DIEGUITO WATER DISTRICT NOTES FOR GRADING PLAN 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES STANDARDS COMMITTEE (WASC). 2- RENEW R THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, R THE EXISTENCE R NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE R STRUCTURE WHHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., UNE CROSSING, LINE PARALLEU14G R PROPOSED CONNECTION SHALL BE RED VERIFIED. All EXISTING R PROPOSED UTIUTY CROSSING WTHIN 10 FEET R PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND/OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES STANDARDS COMMITTEE (WASC) STANDARDS IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6, MINIMUM HORIZONTAL SEPARATION R 10-FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVLED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION R REPAIR R ALL POTABLE WATER SYSTEM EFFECT JANUARY 1, 2010. IN COMPLIANCE NTH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED NTH CATHODIC PROTECTION IN ACCORDANCE NTH WC-17 OR WC-18. LEUCADIA WASTEWATER DISTRICT NOTES 1. LOUD APPROVAL OF THESE PLANS DOES NOT REUEVE THE APPUCANT, PRIVATE ENGINEER OR WORK, R CONTRACTOR FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED WRING R AFTER CONSTRUCTION. 2. OSHA SAFETY ORDERS AND OSHA CONFINED SPACE ENTRY REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES WITHOUT EXCEPTION. 3. APPROVAL OF THIS PLAN BY LOUD DOES NOT CONSTITUTE A REPRESENTATION R THE ACCURACY OF THE LOCATION OR, OR THE EXISTENCE R NON-EXISTENCE OF. ANY UNDERGROUND UTILITY, PIPE, OR STRUCTURE WITHIN THE UNITS R THIS PROJECT. 4. ALL REVISIONS TO DRAWNGS SHALL BE APPROVED BY THE LOUD DISTRICT ENGINEERING IN WRITING PRIOR TO CONSTRUCTION. 5. FINAL APPROVAL R THE PLANS BY DISTRICT ENGINEER IS VALID FOR A PERIOD R TIME NOT TO EXCEED ONE YEAR FROM APPROVAL DATE TO START OF CONSTRUCTION. IF THE ONE-YEAR TIME UNIT IS EXPIRED PRIOR TO START OF CONSTRUCTION THE DEVELOPER SHALL RESUBMIT THE PLAN CHECK TO THE DISTRICT ENGINEER FOR AN UPDATED REVIEW AND APPROVAL ANY RANGES REQUIRED TO THE PLANS SHALL BE MADE AT THE DEVELOPER'S EXPENSE AND APPROVED BY THE LOUD DISTRICT ENGINEER PRIOR TO THE START OF CONSTRUCTION. 6. CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO PROTECT LN) FACUTIES AND STRUCTURES DURING CONSTRUCTION. SHOULD THE CONTRACTOR AT ANY TIME DAMAGE I R PRIVATE SEWER LATERAL FAGUTIES, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK, NOTIFY LWD, MINIMIZE AND CONTROL ANY SEWAGE SPILL AND REPAIR DAMAGED FACILITIES TO THE SATISFACTION R THE LWD ENGINEER AT NO COST TO LNT INCLUDING INSPECTION AND ANY BYPASSING REQUIRED TO SEWER FACIUTY OPERATIONS. DAMAGE CAUSED TO SEWER FACIUTIES SHALL BE REPAIRED IN ACCORDANCE WITH ALL APPLICABLE LWD STANDARD SPECIFICATIONS AND DRAWINGS. SUBMIT FOR LWD APPROVAL PRIOR TO REPAIR. 7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PREVENTING SEWAGE SPILLS: CONTAINING AND SEWAGE SPILLS; RECOVERY AND LEGAL DISPOSAL R ANY SPILLED SEWAGE ARISING FROM ANY WORK ADJACENT TO LWD FACILITIES R ALLOWING A SEWAGE SPILL R FAILURE TO PREVENT A SEWAGE SPILL WIHILE PERFORMING THE WORK. CONTRACTOR WILL BE RESPONSIBLE FOR ALL CLEAN UP COSTS AND PENALTIES ASSESSED TO THE DISTRICT AS A RESULT OF A SEWAGE SPILL CAUSED BY THE CONTRACTOR, TOP OF m STANDARD 1/8 ATRIUM GRATE ��� 18" ATRIUM GRATE PER NOS 1891 OR EQUIVALENT (USE TRAFFIC RATED CAST IRON ADA COMPLIANT FLAT GRATES IN TRAFFIC OR PEDESTRIAN AREAS) RISER WEIGHT - SEE T EXTENTION A WEIGHT 6" 160 LB: 12° 315 LB: IRON TRAFFIC COVER BODY WEIGHT - 607 STANDARD WYE BRANCH STORM DRAIN CLEANOUT DETAIL NO SCALE EXISTING MOD. TRIPLE TYPE "G-3" INLET STRUCTURE PER ROUGH IL GRADING PLANS 6394-G (ELEV 41.33) ) �' EXIST. GROUND EXISTING SHORING 12"z48" INLET ® 3.5' FROM WALL PER ROUGH I- j BOTTOM (FL ELEV. 39.50) GRADING PLANS j=j ! (_ _ 6394-0 PLANTING MINIMUM 18-INCHES O.C. n AND 2-INCHES OF HARDWOOD MULCH 5" DIM. HOLE ®2.25' FROM PER LANDSCAPE ARCHITECTS PLANS BOTTOM (FL ELEV. 38.25) BOTTOM ELEV. 36.00 �, I_..�i ,._ N EXTEND EXISTING 6" DIA. PVC �CLEANOUT AND CAP TO 12" ABOVE MULCH ELEVATION ELEV. 36.00 a I i- -I ELEV. 34.00 � £ .w � .+ K y� INSTALL MEDIA LAYER A-1 ELEV: 33.50 ri, q1 , ° -n `' '^t.Y4•'[�ITH IORETENTION SOIL MIX #'BA EXISTING 3° ORIFICE -R APPROVED EQUAL (2.0' PLATE (FL ELEV. 32.75) o a - ICK) (SEE NOTE 1) (LE. 32.25) INSTALL FILTER COURSE 3" LAYER OF CLEAN AND WASHED ASTM 33 (ELEV. 32.58) - EXISTING PVC PERF. PIPE FINE AGGREGATE SAND OVERLYING ELEV. 51.2.5 `(FL ELEV. 32.777555))� A 3 LAYER OF ASTM NO. 8 (( oV STONE (SEE NOTE 1) �� f1EV, 3025) I� EXISTN'_DRAINAGE STONE It I� BOTTOM OF EXISTING GRAVEL LAYER ELEV. 26.50 WATER OUAUTY/HYDROMOD BASIN NOTES 1. AFTER THE SITE HAS BEEN LANDSCAPED AND EROSION IS FULLY STABILIZED, THE EXISTING 3/4- PROTECTIVE ROCK, FILTER FABRIC, AND ANY DEBRIS OR SILT FROM THE ROUGH GRADING OPERATORS SHALL HE REMOVED FROM THE EXISTING BASIN. THE EXISTING DRAINAGE STONE SHALL BE INSPECTED FOR ANY LEACHED SEDIMENT R DEBRIS AND CLEANED R REMOVED AND REPLACED AS NECESSARY. ONCE THE DRAINAGE STONE IS RESTORED, THE FILTER COURSE AND MEDIA LAYERS CAN BE INSTALLED PER THE ABOVE DETAIL. 2. SPECIAL INSPECTION OF ALL POST CONSTRUCTION BIRILTRATION BASINS BY THE ENGINEER R RECORD R ANOTHER LICENSED CIVIL ENGINEER IS REQUIRED AT THE FOLLOWING STAGES PROGRESS PICTURES R BIRILTRATON BASIN CONSTRUCTION SHALL BE TAKEN AND PROVIDED TO THE CITY AT THE FOLLOWING STAGS: 1. BASIN EXCAVATION 2. PLACEMENT OF PERFORATED PIPE RISER PIPE, OUTLET PIPE, PIMP ORIFICE, ETC. 3. PLACEMENT R DRAINAGE STONE LAYER • 4. PLACEMENT R ENGINEERED SOIL LAYER '• 5. FINAL BASIN GRADING ** 6. FINAL COMPLETED BASIN NTH VEGETATION ESTABLISHED ** 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL RAIN TO APPROVED BMPAUP FACIUTIS AND/OR TO TURF OR • PERFORMED DURING ROUGH GRADING LANDSCAPED AREAS WITH. ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROOM THE SITE. ALL IMPERVIOUS AREAS •* PERFORMED AFTER SITE IS LANDSCAPED AND SITE EROSION IS FULLY STABILIZED. LOPE TOWARD THE OVED THE JPED S. ry 4. ALL STORMWATER I P/BMPRFACILITIES PSHOWN HEREON SHALL NOT BEFMODIFIEDEAR ALTEARD WITHOUT A PERMIT WATER TTAT SCALE DROMOD BASIN FROM THE CITY. NO SCALE IHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT ZIN AS BUILT 4-1-21 DE$CIilP¶ON: PT N0. 1 SEA 1FR-022 PER ROES 17271 //,/� -yL- LOCATION: AD. 2" IRON PIPE AND DISK IN AC HORIZONTAL VA //�'�JJ.FIrv� PAIR. NORTH SIDE OF LA COSTA AVE AT CLINTON E. HALE DATE VULCAN AVENUE 13' OFF SHOULDER VERTICAL N/A RECORD FROM SAN DIEGO COUNTY 4-1-21 ELEVATION: 62.949 DATUM: N Vgp 88 Vl W 1�0 N N I' CHAMFER (T CORNERS TOP BOTTOM) 18" WIDE X 29 I° DEEP THIN -WALL TYPICAL ON ALL FOR 12" RCP ANT 12" ATRIUM GRATE PER NOS 1290 OR EQUIVALENT o (USE TRAFFIC RATED CAST IRON ADA COMPLIANT FLAT GRATES IN TRAFFIC OR PEDESTRIAN AREAS) a 18" CATCH BASIN NO SCALE RISER WEIGHT - SEE TA EXTENTION A I WEIGHT 6" 94 LBS. 12" 1188 LDS. BODY WEIGHT - 339 LB'. I" CHAMFER (TIP. 4 CORNERS TOP AND BOTTOM) If WEE X 16" TALL DEEP THIN -WALL KNOCKOUTS TYPICAL ALL FOUR WALLS FR PVC AND SMALLER 12" CATCH BASIN NO SCALE OF LINE) a PER PLAN TYPE 1 OUTLET "FL" MORE THAN 36" BELOW "GR° NO SCALE BASIN DETAIL NO SCALE 3 ZSUU YSI AIK PLAULU ULMI It WTH 6 X 6-WI.4 X WI.4 WWF MODIFIED D-75 TYPE 'B' BROW DITCH NO SCALE 5 6" 6" 6' CURB 4" PGC 6' 6 v /OVA i DATE: 2/Z7//9 R.C.E. NO.: 58007 STO 1 06/30/20 DATE SIDEWALK DETAIL MODIFIED TYPE V BROW NO SCALE DITCH PER DETAIL THIS SHEET 12" 6" 81 6" 12" 1.5" X 1.5" SLOT IN TOP OF CURB AT 5' ON -- rc CENTER IS" X 1.5° SLOT 4° PCC WALKWAY FINISH IN TOP OF CURB , a L PER LANDSCAPE PLANS A3 REPAR 24' ON AT 5' ON CENTER 2.0% (MAX) CENTER, EACH WAY 6" CURBI „ DIVISION APPROVALS APPROV EDQ DB,J tMER DATE CITY OF ENCINITAS - DEVELOPMENT SERVICES ENCINITAS BEACH RESORT PRECISE GRADING APN: 216-041-26 -014 18-257 SUBC D AN. DRAWING NO. 14083-G LDEV-011233-2018 CONSTRUCTION NOTES O1 - INSTALL 6" DECORATIVE P.C.C. OVER 6" CLASS 2 AGGREGATE BASE COMPACTED TO 95% PER ASTM D1557. FINISH PER LANDSCAPE PLANS. PROTECT IN PLACE EXISTING STORM DRAIN PER GRADING PLAN 8394-G. PROTECT IN PLACE EXISTING WATER LINE PER IMPROVEMENT PLAN 8745 I. 'V A INSTALL 6" CURB PER SDRS DWG G-1. INSTALL BEACH ACCESS WALKWAY AND APPURTENANCE \ - \ '// PER DETAIL, SHEET 2. 1 \\� Ir. \� �\ ��- PROTECT IN PLACE EXISTING SEWER LINE PER �\ � � � _ 11 ( � � � \ 3 \ 1 � �`� � ��� K �\ IMPROVEMENT PLAN 6745-I. �\ PROTECT IN PLACE EXISTING SEWER MH PER IMPROVEMENT PLAN 6745-I. RAISE TO GRADE AS n V NECESSARY. EXISTING STORM DRAIN TO BE REMOVED PER GRADING PLAN NO. 6394-G. OQ (T y� V AV A �� OF EXISTING UTILITY TO BE REMOVED PER GRADING PLAN NO. PROTECT IN PLACE EXISTING UTILITIES. IF X�F vvvvvv �� SHEET 2. vvv 16 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, A A EXISTING STORM DRAIN EASEMENT �t 2 V A A %� PER DOA. 2019 0023339 - \ \ \ ✓\ \ �1\ j \ 25 - EXISTING RETAINING WALLS PER ROUGH GRADING PLANS RECORDED JANUARY 22, 2019/ j - 6394-G. AND EMRC PER DOC. 2019 0023349 t � j \.� RECORDED JANUARY 22,2019 14 , _�� i \O \\ 33 - REMOVE AND REPLACE EXISTING RIP -RAP WITH RIP -RAP � � � i ENERGY DISSIPATER PER SDRS DWG D-40, FACING RIP -RAP (T=1.4') TYPE 2, D.G. FILTER BLANKET (T=1.0') EXISTING TYPE A 4' CAB � BA� � NOTE' CLEANOUT PER GRADING q A i ! % PLAN NO. 6394-G LE RRIER T -i6 A�.p41 LANDSCAPE' FS 41.8 13q� �/b j- \ �� \ 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR PLANS 61 42.82� '� O ^ . / \\ \\\ ALA ACCESSIBILITY COMPLIANCE 6" CURB POST � , \ \ I/a. \\ �'� 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE SATISFACTION OF \\\ \ POOF'L THE DEVELOPMENT SERVICES DEPARTMENT. OP _ O i f , / TC 42 24 ,O p O J 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN I GRADING DAYLIGHT �� �° 9%4,99p;!� � IF� ON THE LANDSCAPE PLANS. If SOUTH CARLSBAD / ! To a'// rc 4z.33 ?p. �� 00, oil J SEE CURB INLET 1.50% / a n ( C o ♦ ��,� p STATE BEACH DETAIL THIS SHEET ' f,(- TC 42.40 d TG 422Z s (/ TC 4180' �' 1ya- ,� a y \ 9' � \\ A\ p °p 000 TC 41..28ANG PNT 2 n �- \� \ \ t p o FL 41.78 r / 11 TC 43.69 y ,�" r \\ oo°opp TC /42.17 / e ��6°�' - _ 6 CURB AA t AA \ o ° 1 1 1' CURB a v �� v v pogo ? f 43.50V� \�� a� I A \� _ o000 WALKWAY FLUSH TC 41,55 �' I GB 2 *��A V �V o r a EXISTING IMPROVEMENTS PER � �v \ \ p WITH PAVEMENT j (( EC 7C 42.38 - 15 IMPROVEMENT PLAN N0. 6169-1 �� TC 84�.16 _V TC 4218 FL 41. 1.6B PROTECT IN PLACE \ t I FL 41.71 REVISED IOD EASEMENT FOR I / VERTICAL PUBLIC ACCESS 0 �. o 2y / EXISTING PUBLIC STORM DRAIN \ / ORIGINALLY RECORDED AS % t DOC. 2000-0615532 - TC 43.21 - ` �� 7 \ PUBLIC DRAINAGE EASEMENT t f DATED NOVEMBER 13. 2000 %' \a - 0� A PER DOC. 2019-0215167 - E p \ �_\ \ REC. JUNE 04 2019 -- �\ f NOTE: ETC 40.38 ///,q" �° �^< - A a ' \ V � V FS 42.01 C FOR OFFSITE IMPROVEMENTS SEE STATE PARKS �C- F `� �� 7� / TC 41 00 0 k TC 43.24 FL\TC 42.48 \ RIGHT -OF -ENTRY PERMIT: _ DA' 1. CURB ' �\ r \\\\\\ FL=41.65 DATED: s/ �� _TC 44.22 a �� �'% 3S� CABLE BARRIER \ O 7 EXISTING TYPE 'A-1' CURB JANUARY 9, 2019 7 1 q =: � - a�- .o . 25 A, A PER LANDSCAPE \ CABLE BARRIER PER �5� PLANS\� I INLET PER GRADING PLAN LANDSCAPE PLANS N0. 6 \ 394-G 8• F 7 TC 44 70 GB, EC/{p A�' - �� �` FL 42.00 o i TC 39 83 : c '- C / 5' \� FL 4260 CURB ' � 1 - � � FS=36 00 h � _ - v BC, GB IF i eW /� ` TC 45.20 _ a a h TW 45 3 BIOFILTRATION / HYDROMODIFICATION BASIN SHALL BE RECONFIGURED AND r �� \\\ HAVE BIOFILTRATION MEDIA �\ / AND FILTER INSTALLED PER WATER \ \` QUAUTY/HYDROMOD BASIN NOTES AND `', fTC 45.88 DETAIL ON SHEETS 2 AND 12 / ;'\� CURB INLET DETAIL 10 GB, BC (3344 S.F. MINIMUM) - \A NO SCALE „f y - E70STING SLOPE TO REMAIN / a EMERGENCY ACCESS EASEMENT 47.00 / NO DISTURBANCE ALLOWED \ \�\� �\ PER CERTIFICATE OF CORRECTION _7 \ /� TO MAP 18587 RECORDED AS ��\ e _-DOC. 2019-0117080 i �I �� r DATED: APRIL 02, 2019{7((� A\\ a n:., rITIN -- i..IA. SEE SHEET 5 = PLAN VIEW �1}5 ,0 g,� O 0 20 30 sq,zd u . eX c J ^ 1 w w a' SCALE ,"= 10' r >o SCALE 10 = 10 °J•U aiN� oe�� B AF Ch45 p�J Ls ... _ - jl/ `. ,\ n i V �A nz N KEY MAP aw z'zo SCALE AS -BUILT ENGIN ERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. Oz DO PLANS PREPARED UNDER OF SUPERVISION OF REC M D: APP OVED: GRADING PLAN FOR: wy n HORIZONTAL: 1"=10' /�` � G- -��- DATE: I/A6/1 G�� ENCINITAS BEACH RESORT 14083-C a z m CLINTON E. HALE DATE R.0 E. NO.; 58007 STEVEN OW EDWA D J. MER PRECISE GRADING, z 8 2 w VERTICAL: N/$ _ (.5 at �. `; AP_N: 218-041-E6' w oKtM 4-1 21 MARK L. HENNING EXP.: 06/30/2 DATE DA PLANNING CASE NO: TPM-89-014 18,257 SUBC � � SHEET 3 OF 2S .. �< F � E E SENT N LDEV-011233-2018 WIDE WHITE STRIPE IL DE DETAIL S1 GR 50.93 IE 47.77 1: MATCH EXISTING 2 4" WIDE YELLOW STRIPES 1 ARROW I(I TYPE 1 (10,-0") i ARROW _. ._ h t\/ U FG (52.9) 4" 'WIDE WHITE V0 A, >V 14 STRIPES D- _ E V/ 18" SD C P R 0 DETAIL SHT 2 _ _ q TC 51.79 `GR 52.99 --'- IE 4762- 6_ 2 4s MADE YELLOW - STRIPES' TC 52 1 Tn 12s7 , a WIDE WHITE C 0� 7 2OACHMENTS WITHIN CITY R/W- PER EMR 2019-0127080 REC APRI 09. L 09 2019 FG 5 -w = f FG 52.71 - �- i - 10 10 -_- 31 R/W OEDICATION PER ❑ _ DOC 2019-0010408 REC. JAN. 10. 2019 1 ���� �� / - - STRIPE .40R' D • TC 52.90 / "S. PROP. WALL 12 SEE SHEET .� - D ` �D 7 D e /TC 94.28d 15 FOR PLAN AND PROFILE �/ M1 ' SEE LANDSCAPE PLANS FOR BENCH/PLANTER WALL DETAIL >FS 53 8 - + 00 f f' FS 53.15 R 10 O r*1 ° TW 54.00 it 11 O 171 D D W �• A 83 / TC 53.84 W 4 FS 5 . TC 5.92- q , Q� W v _ 7 _ W \ f 27 T���Y 1/ 1 FS .56 18" SO54.07 DETAIL H PI DEL SHT 2 (SOLID COVEF TOP 53.97 IE 46.72 a,. FS ACC r.511/1 �/ 0 CURB ° PRECAST TRUNCATED DOME + TC 53 02 ?, PAVERS 'ACKERSTONE 12X12 -0" CURB D' IN ONYX OR APPROV EQUIV.n - _D > STD DWG. G 30 (TYP) D D + 31 F ,. may/ TC 5323 + � p � � ` -.. 3p. 53.820" CURBS o n D 54 88 °°..' /O CURB �D TC 54.32 D 0 CURB D 54 85 - :7 ...._..,..-- 0` CURB ° %..°° D5.00 IS WIDE BY 0 DEPTH PCC END 6" CURB INTO WALL =FS 78.97.-.,_, . D A n0 78.90 HIG WALKWAY AND ELEVATIONS t LOADING (SEE DETAIL I - r 1 D 1 ° FS 54.85 s 101- --68 EXISTING IMPROVEMENT PLAN NO PER IMPROVEMENT PLAN NO. 6169-I _PEDESTRIAN RAMP SEE DETAIL THIS SHEET "'-- PERMANENT ENCROACHMENTS WITHIN CITY E ---.PER EMRC DOC 2019-0127080_____�- Cp REC APRIL 119, 2019 FG 55.01 g CURB CUT AND BROW DITCH TRANSITION .! . 1 PER DETAIL THIS SHEET ` �,�FG 55.9 15 MATCH EXISTING TC 55.9 O �L- TC 56.0 FG 57.4 r _ E V/ n �IEOFI �4 GR 54.56 IE 50.50 GATE / FENCE PER ARCHITECTS PLANS PROP, WALL 15 SEE SHEET 19 FOR PLAN AND PROFILE E FG(57.4)\E � E -_ 14 EXISITING CURB 4" THICK PCC TRANSITION FROM BROW DITCH TO PCC PAVEMENT G WALL IG PLANS s ^~ ti MODIFIED TYPE 'B' \�j\ BROW DITCH W=1' TS �/\ PER DETAIL SHEET 2 c-- 0�7SlF6 D �j�l,p� `'�"SF' p`�RI�S $ CURB CUT AND BROW DITCH 5975E o �'oFg Flo°" Q� ? TRANSITION DETAIL 4SFFgoiF.I, NOT TO SCALE ELEVATED WALKWAY AND DECK DETAIL NOT TO SCALE �. 4 PRIVATE SEWER LATERAL DATA TABLE Q LENGTH BEARINGIDELTA RADIUS SLOPE DESCRIPTION 1 38.57' S29037'25-E - 8.84% 6" PVC 2 10.97' S54'44'43"W - 8.83% 6" PVC 3 2.52' N90000'00"W - 8.83% 6" PVC 4 19.34' N3515'17"W - 2.00% 6" PVC 5 10.99' N89'24'04"W - 2.00% 6" PVC NOTE: 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR ADA ACCESSIBILITY COMPUANCE. 2. ALL GROUND MOUNTED UTILITIES. SHALL BE SCREENED TO THE SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. FS (55.1}% 12" WIDE BORDER r '� TC 55,27 ,D PER SDRS G-32A ,/-6" CURB �, '0.. CURB, `DETAIL A 6" CURB< "ETC 55.21 TRUNCATED DOMES PER \FS 54.71 TC 54.75� 6" CURB STD DWG. G-30 0" CURB PEDESTRIAN RAMP DETAIL SCALE: 1" = 5' SEE SHEET 5CONSTR CT ON NOTES PLAN VIEW SEE SHEET 10 Ye a sc SCALE 1" = 10' � .\a ' !e 27 - INSTALL 4 WIDE BLUE STRIPE AT 3 O.C. O - INSTALL SEWER CLEANOUT PER LWD 70• INSTALL 6" DECORATIVE P.C.C. OVER 60 CLASS 2 15 - PROTECT IN PLACE EXISTING UTILITIES. 28 - CONNECT TO EXISTING SEWER CLEANOUT PER 6169-I. STD S-25 AGGREGATE BASE COMPACTED TO 95% PER ASTM 35 - INSTALL SEWER SAMPLE BOX, JENSEN D1557. FINISH PER LANDSCAPE PLANS. i6 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER pg - CONNECT TO E%ISTING SEWER SNB PER 6169-I MODELEV20 PRECAST MODEL EV200 OR DETAIL, SHEET 2. APPROVED O - INSTALL 6" CURB PER STIRS DWG G-1. 31 COVEREBAIN TRASH TO 18 - INSTALL ONE FOOT WIDE CURB CUT AND PCC CATCH ER DETAIL SHEETT 2 W/N RA REM, TRITON 10 0 10 20 30 12 - INSTALL 5' WIDE SIDEWALK PER DETAIL, SHEET 2. APRON, DIRECT RUNOFF TO BROW DITCH. VPF FILTER SERIES', CARTRIDGE 'TR10-CART WITH FOG - EXISTING UTILITY TO BE REMOVED PER GRADING 26 - RETAINING WALL PER ARCHITECT PLANS. MEDIA OR AN APPROVED EQUIVALENT FOR FILTER. PRIVATE STORM DRAIN DATA TABLE Ll LENGTH BEARINGIDELTA RADIUS SLOPE DESCRIPTION Li 87.59' S8739'14"E - 1.00% 12" HDPE PVT SD* L2 101.41' S31-53'35"E - 2.68% 10* HDPE PVT SD* L3 45.77' N536'53"E - 1.00% 10" HDPE PVT SD* 14 FILTER TO BE PROVIDED WITH AN OVERFLOW CAP TO *HDPE PER AASHTO M252 & M294 WITH WATER TIGHT JOINTS KEY MAP aw SCALE 1" = 10' PLAN NO. 6394-G. BE SOLVENT WELDED TO THE TOP OF THE FILTER. m iANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT wmm- ENGIN ERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NOMUN. z o CLINTON E. HALE DATE /�Jjv� - REC D: APPROVE PLAN FOR: w> zz LOCATION FD. 2" IRON PIPE AND DISK IN AC Y/✓//� DATE: 9/i/ro P ENCINITAS BEACH RESORT p z j 1 AS BUILT a-1-21 DESMPTICN. PT ND 22s1AasR-o22PERgas17271 PLANS PREPARED UNDER SUPERVISION OFGRADING HORIZONTAL: 1 -10• m/ /- � z PATH. NORTH SIDE OF LA COSTA AVE. AT 14O4A3-G z p VULCAN AVENUE 13' OFF SHOULDER R.C.E. NO.: 58007 STEV NO K EDW D MMER „�- -' PRECISE GRADING-. wo 4tC FROM: SARI DIEGO COUNTY VERTICAL: � � APN: 216-441-26 4-1-21 MARK L. HENNING EXP.: O6f30f20 DATE DA no ELEVATION: 62.949 DATUM. NAw 98 V1EWE INSPE O NI N IN PLANNING CASE NO: TPM-89-014 18-257 SUBC SHEET 4 OF 25 < J _ N LDEV-011233-2018 /ILL- 1// ////}y SEE [ SHEET %3 SAMOVE AND WCUT LINE (LACj 1.5'\� ,/(%NOTE: `'y l/ TC BC` its° J TC 39.83f dai a TW 4 53 N `� rjY y �� FOR OFFSITE IMPROVEMENTS SEE STATE PARKS /' ^. 1 iA- f' TC 452 ° h a-. BIOFILTRATION / HYDROMODIFICATION T\ RIGHT -OF -ENTRY PERMIT: i i.' 'SO;p'r' 1 CURB GB BC .y BASIN SHALL BE RECONFIGURED AND ITC 16.9fi GB, BC - JI r DATED: JANUARY9 2019 f- 6 HAVE BIOFlLTRATION MEDIA +'✓ a ° AND FILTER INSTALLED PER WATER QUALITY/HYDROMOD BASIN NOTES AND _ •� /� % CABLE BARRIER P� TC 45.68 j DETAIL ON SHEETS 2 AND 12 LANDSCAPE PLANS Y ITC 17.13 } 3 GB.760 mil. - TW 47. TC 37.81 .ram A . / TC ` �'" .�. r ��' V IE OUT 37.00 - TC 46.38 L / REVISED IOD EASEMENT FOR GB. EC e /A �qA',' / �( .VERTICAL PUBLIC ACCESS / _ / ° �... v 'ti� r n j, ORIGINALLY RECORDED AS - ' ° /--� ?s ' 25, 8 aD CB_ / DOO. 2000-0615T32 }/ �; //f/ - - _. M -- f : `' / ' 'DETf IL SHT DATE Q NOVEMBER 13, 2000p`Za - f.CR 45.50 / 3823h - d � - TC 48.71 1 LIT/ �y 1' CURB GB BC / �. PRC lg'I' a R" GB, EC a 7 n 11 .°'^, CABLE BARRIER PER LANDSCAPE PLANS 7 IT, r � %i / � CABLE EARNER PER' _ LANDSCAPE PLANS ., t �A IE OUT 37.00 \ t'/ \ j 2 ,x%'TW 48. - L7 '; i \ , a• r; � i 7 I i ; ? a° DETAIL .HT 2 EXISTING SL03E fO REMAIN i (.� y. q •TIC 47.98 18' SO CB PEF �' c- NO CISTIIRBHNCI Al LOVED ' FII47 3)• GF 47.3q I.FL 7FI. IE 31OS\y_'2\�\ CB, BC \`� of 3 .l7 0" CURB s S 4848 ds a .:. j TC 48.74.. .L FS 48.48 BUILDING JICF FIFE BUILCJN RO_ ri i) ! V IILI -. 1 CURB FL 78.65 G8. PCC i r, . S. °.8 r i '' i I ✓"� -�- ` a ^ TC - "GRADING DAYLIGHT ` a. a TRUNCATED DOMES PER PROP WALL 2 SEE ROUGH GRADING PLAN - i S 6rC' ' N0. 6394-G FOR PLAN AND PROFILE _ y ,� 7 ° _ ° ti :�' - ST DWG. G-30 TC 48 F4 ' - - FL 7 .75� EMERGENCY ACCESS . EASEMENT PER CERTIFICATE OF CORRECTION TO MAP c' �� T • O6� _. ° a ° 'a T 49.35 f �.� 16 -"� { ,� I 7 - STAIRS TO BE CONSTRUCT- 18587 RECORDED AS - n. `; d ,_ `,° -.` f;� ..\ \ I H ,f t �i ' PER THE BUILDING PERMIT° H-. DOC. 2019-0117080 TC 51.65 - , a -- . =.-- -'- _ $' ! ' _ ' P .18" SD CB PLIN l `_ ' = DATED: APRIL 02, 2019 DETAIL SHT e' :" 1 �\ -� lr BE SHT 2 i 1 i 'f y� 9 '� r'_ W (TIED 53.54) a a 10 5 kh OR 48.67 it E 71.83 IE 43.00 \\ BROW DITCH / �°' ' -)' `, \ , ,;_✓ �. '1 q� ADDED FG 85.90 n7�Y ,DE IL CB PERLILL O / W ETC 6�66 A_ i _ 18° CB PER DETAIL SHT 2FL 7 ti,� r - GB, PRC - ;='� '" DETAIL SIT 2 GR 65.16 / a , . �.-, , - ....._-_ - - '.GR41.39 IE 61 70 _ _ � 74.00 6 8 N � ° CONNECT ID ° ` TIC 52.11 4.- - 4 ^ W . GB, EC a -1 - TW 57.34 IE 40.49 (2=10") - ` FFL 66.21 / a `' �� _ �DETAIBL SHT 2 ,.CONNECT TOEXIST D r . -LB F / _ \ ° OR 54.fi1 _ IE 43.79 (8 'T L 66 -IE _48.00 TW 57.34 BROW DITCH TO BE PROP WALL 3 A 5 66.68 -.. - - - CONSTRUCTED 2 FEET FROM - _ SEE SHEET 14 FOR 1¢ - BACK OF WALLPLAN AND PROFILE - tG - _ -..PLANTING PER LAA ALLOW FORNDSCAPE' l y - - _ - ARCHITECT'S PLANS *; rF ����y DING DAYLIGHT �npp'PO Y � TW 60.67 -3:1" 2'1 �^ RL 1 CONNECT TO 10" SOL IE 40.76 (B")- ` - - -.l` _. �... 'Fs 6698� \ >-- BUILDING POC TO EXIST 12" SD FS 66 98� IE 45.96 FG FD4 T4525 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE _ AS BUILT 4-1-21 DEiCMP1101k PT No. 22 SfA am-m PER R0517271 LOCATION: ED. 2w IRON PIPE AND DISK IN AC HORIZONTAL 1"=10' PATH NORTH SIDE OF LA COSTA AVE. AT - �, WLCAN AVFN 13' OFF SHOULDER VERTICAL: NIA - - RECORD FROM SAN DIEGO COUNT/ SEE SHEET 10 PLAN VIEW SCALE 1" = 10 rLruvo rrlarmmau UIVuER our Ercnoiui4 yr f' /z- DATE: ZA7/i9 LINTON E. HALE DATE R.C.E. N0. 58007 4-1-21 AARK L. HENNING �LNIVK `- EN- - - EXP.: " 06/30/20 I 53.97 PRIVATE STORM DRAIN DATA TABLE LENGTH BEARING/DELTA RADIUS SLOPE DESCRIPTION Li 80.90' N80'03'17"E - 1.00% 12" HDPE PVT SD* L2 2.87' S40'00'05"E 3.00% B" HDPE PVT SD* L3 49.56' S72042'18°W 14.61% 8" HDPE PVT SD* L4 25.50' S19'32'53"E 2.GO% 10" HOPE PVT SD* LS 24.9T N19.3253W 2.G4% 10° HOPE PVF SD* L6 30.50' N4718'31"E - 26.07% 8" HDPE PVF SD* L7 2.58' N4110'39"W 200.% 8" HDPE PVT SD* FL9 48.93' S72'43'29"W 36.60% 8" HDPE PVT SD* 37.53' S64'47'04"W 36 58% 8" HDPE PVT SD* *HDPE PER AASHTO M252 k 4294 WITH WATER TIGHT JOINTS mt CONSTRUCTION NOTES E4 O INSTALL 6" P.C.C. ORW AGGREGATE BASERATIVE COMPACTED TO9 5%"PERASS ASTM D1557. W FINISH PER LANDSCAPE PLANS. I•�"4 2O - PROTECT IN PLACE EXISTING STORM DRAIN PER GRADING FTC/--11 PLAN 6394-G. PROTECT IN PLACE EXISTING WATER LINE PER IMPROVEMENT PLAN 6745-I. PROTECT IN PLACE EXISTING FIRE HYDRANT PER W IMPROVEMENT PLAN 6745-I. O7 - INSTALL 6" CURB PER SDRS DWG G-1. O8 - INSTALL BEACH ACCESS WALKWAY AND APPURTENANCE PER DETAIL, SHEET 2. 10 - PROTECT IN PLACE EXISTING SEWER LINE PER IMPROVEMENT PLAN 6745-I. 11 - PROTECT IN PLACE EXISTING SEWER MH PER IMPROVEMENT PLAN 6745-I. 16 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, SHEET 2. EXISTING RETAINING WALLS PER ROUGH GRADING PLANS E 6394-G. ®- INSTALL (5' X 5') FACING RIP -RAP (T=1.4') TYPE 2 ENERGY DISSIPATER PER SDRS DWG D-40, D.G. FILTER BLANKET (T=1.0') 33 - REMOVE AND REPLACE EXISTING RIP -RAP WITH RIP -RAP ENERGY DISSIPATER PER SDRS DWG D-40, FACING RIP -RAP (T=1.4') TYPE 2, D.G. FILTER BLANKET (T=1.0') NOTE: 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR ADA ACCESSIBILITY COMPLIANCE. 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED. WALLS ARE SHOWN ON THE LANDSCAPE PLANS. EXISTING SHORING PER ROUGH GRADING PLAN 6394-G 18"X18" STORM DRAIN ROUND SLOPES THAT CATCH BASIN MATCH EXIST (TYR) WATER QUALITY/ EXISTIN GROUND HYDROMOD BASIN uz r ,y 8" HDPV SD MM+� 1' MIN. FG 6.0 SECTION G-G TYPICAL SECTION F-F LANDSCAPE DRAINAGE SWALE NO SCALE NO SCALE ;, It O \ U U 10 0 10 20 30-(tw ILII�� NQ SCALE i" = 10' KEY MAP o m < F: o N � ING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. i o i APOVELI' GRADING PLAN FOR: ENCINITAS BEACH RESORT ry GSC/./�M6Yn 1a08 ED ER PRECISE GRADING,. m _�� DATE PLANNING CA - SE NO: TPM-89-014 18-257 SUBC _ -. SHEET 5 OF 25 i n " LDEV-011233-2018 d/ J/ -� v-��cT✓""�� TC 17.13 /� / - J �„�- REMOVE AND REPLACE 1.5� r% � PRIVATE STORM DRAIN DATA TABLE C- J ! OF EXISTING + i / � 17 j IENDTHLN19*26'27mW LTA RADIUS RADIUS DESCRITION I SOUTH CARLSBAD ���I�C G A I G DAYLIGHT / _ NOTE: STATE BEACH 9 J, j 31.43'2"E 1..95% Bw HDPE PVT o* ip \"� L2 5.14•"W - 1.95$ 8' HDPE PVT SD" FOR OFFSITE IMPROVEMENTS SEE STATE PA S N 7 .61, - / RIGHT -OF -ENTRY PERMIT: SAWCUT LINE X L3 3.34 237.4$ 5" HDPE PVT SD* DATE . JAN UARY 9 2019 p1'k' Y 4 TC 15.82 7 R 4' - 'HDPE P& ER AASHTO M252 M294 WITH WATER TIGHT JOINTS REMOVE AND REPLACE 1.5' J i OF EXISTING AC (TYP) - .. GRADING DAYLIGHT ! - d\- -_ -� I CONSTRUCTION NOTES aA• - JC' 17.00 . ' ' PROP WALL 8 K I +, / Oj - INSTALL 6" DECORATIVE P.C.C. OVER 6" CLASS 2 SEE SHEET 17 _ w :%N _, AGGREGATE BASE COMPACTED TO 95% PER ASTM D1557. ^'� -\ I FOR PLAN AND I 7C 16.00 FINISH PER LANDSCAPE PLANS. TW 17 33 " PROFILE I I l 1 (y PROTECT IN PLACE EXISTING STORM DRAIN PER GRADING PLAN 6394-G. ''- v_�— _ `--- � � � � a.%' O3 - PROTECT IN PLACE EXISTING WATER LINE PER TC 22.77 ° -- - ----- rn - - IMPROVEMENT PLAN 6745-1. 11 CURB ° -.i CB, EC ""-V -- - -- - 20.63 z `� !� ,- �,_d ° �. ' - - PROTECT IN PLACE EXISTING FIRE HYDRANT PER IMPROVEMENT PLAN 6745-I. 30.63 GB - .. - D - INSTALL 6" CURB PER SDRS DWG G-1. 16 �- - WALKWAY AND APPURTENANCE 30.54 �- =B, PCC 46 ° 1� 1 U e�r'-' O PER DETAIL, SHEET C2. GO, PCC %� , -� 10 - PROTECT IN PLACE EXISTING SEWER LINE PER q36% IMPROVEMENT PLAN 6745 a °-I. A ' /� fl - PROTECT IN PLACE EXISTING SEWER MH PER 10- _a-' °-d ,- ' e _ _. --:+ IMPROVEMENT PLAN 6745-I. TC 31.2 ° --' tt`t TC 26.97.. ° + '" - 1' CURB% - PROP WALL 2 SEE ROUGH GRADING i ,.-(TW 5354)��y'� a- INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, 1 CURB -_ _- - -. GB __ PLAN NO. 6394-G FOR PLAN AND - '-'� i--' �� SHEET 2. 16 - � -� PROFILE - - - _ TC 31,16 - ,�. '� 17 EXISTING AC TO BE SCARIFIED TO A MINIMUM DEPTH OF 1 CURB _ _---- - y�" - 1.5-IN AND OVERLAYED TO MATCH EXISTING FINISHED m GB. PCC /' T _ �� _ SURFACE_ '� E-y - / - LO NOTE • _ �,...:_ W v� !(TW 49.50) ° 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE W REVISED IOD EASEMENT FOR _ PRIVATE FACILITIES FOR ADA ACCESSIBILITY S VERTICAL PUBLIC ACCES_ - 1 - COMPLIANCE. -- --- -_ '- -- ORIGINALLY RECORDED AS - - ' �+ v - °. ° .ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED DOC. 2000-0615532 �"- DATED NOVEMBER 13. 2000 5 `4 - - 00X SATISFACTION OF THE DEVELOPMENT SERVICES - �_- �%-' ' _.. -•r'T A / Nrn. �� 1 a 2 DEPARTMENT �•"Y .' PROP WALL 33 �l `�''SEE SHEET 14 FOR 'a- s_ ,."TC COLOR/MATERIALS SPECIFICATIONS FOR THE TC 57.02 G BC_ a PLAN AND PROFILE PROPOS ED DWALLSARESHOWN ON THE LANDSCAPE CONNECT TO _ EC ' " a e 3 PLANS. E EMERGENCY ACCESS EASEMENT -- _ - - : v r•/ '° EXIST 18 S a \-- , D,_ -PER CERTIFICATE OF CORRECTION �� la E 43.98"(8)- TO MAP 18587 RECORDED AS _ ��//••��i�' `�.. �� " - GB. EC .. i�� --- TC 58.11 a•. -00C. 2019-0117080 _ —.. .._-, i—.-' :.D'.'. n + +A ''n X_VERT BEND.:.` a d ° NO. I DESCRIPTION SEE SHEET 9 SCALE 1 1 1 1 1 ilk - :,1 1 �. O' 1 I'L / DATE; 1 :11 MARK HENNING 061 1 ■I�IIIIIIIIIIIIIIIIIIIIII■ 1� ■�� L .� :, 1 } 1 1 : a 1 1 I U :_ -- 1:7dvd>Y7II.1.i93�5ii7:7t.9�N[�7i7i.fA1:1Yyi>• DIVISION APPROVALS AP OVED EDW ME� DATE Y ESS1D z n n m 9,z JrCRt�1� II 0 M 10 0 10 20 30 SCALE 1" = 10' KEY MAP CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. \DING PLAN FOR: ENCINITAS BEACH RESORT AO�R* PRECISE GRAPINP T, APN: 216-041-26 _ ANNING CASE N0: TPM-89-014 18-257 SUBC "HEFT -B 6F'11 -011233-2018 SEE SHEET 11 9 TC 1 E9.71 "�... �� ail L 4 Be yR ti '^ �V if \\ TC 20.33, ' \ \ ;\\� .. 1. BCRB TC 67.58 �. `���s_." 4 EP 671 '...END CURB` \� ' \ 1'� \ \\,-. > .,;,� \ ^ ^'v. PRIVATE STORM DRAIN DATA TABLE LENGTH BEARINOrOELTA RADIUS SLOPE DESCRIPTION Lt 2.16' N7542'11"E - 2.00% 12" HOPE PVT SD* L2 6.75' N33'20'25"E - 91.14% 10" HOPE PVT SD' L3 14.13' 11 517'02'E - 50.25% 8" HOPE PVT SDI if *HOPE PER AASHTO M252 & M294 WITH WATER TIGHT JOINTS TC 22.15.... EXISTING OFFSITE EMERGENCY � _ ACCESS ROAD EASEMENT PER y-y �� 78 .;` EC -. - �. JANUAROY223�2019 �'N` v: \^�.. , �h �� ^ C STRUCTION NOTES AND EMRC DOC. 2019-0024341 _ REC. INSTALL b" DECORATIVE P.C.C. OVER fi" CLASS 2 AGGREGATE V�. �� . JANUARY 23, 2019 x ` A ^"-� BASE COMPACTED TO 95% PER ASTM D1557. �` � -.' \ �'� FINISH PER LANDSCAPE PLANS. "a fin.. \ (TW 867 )\ �\ v \� \ �` y TC 42.77, °2O - PROTECT IN PLACE EXISTING STORM DRAIN PER GRADING PLAN '.� ,CAP EXISTING 8" 1. a' - r °' , V ^�� "` 6394-G. '. -i �T STORM DRAIN o - . r < -r y ` �,•�. TC 66.71 ` ,� 1GB, E C n '�-'.� NOTE _ PROTECT - EC >7-IN PLACE EXISTING WATER LINE PER IMPROVEMENT ! r d t r 3 1 � � OFFSITEMPROVEMENTS SEE STATE PARKS -. O v,.. FOR FOF-E _ PLAN 6745-I. ^ RIGHT -OF -ENTRY PERMIT: _ -°°��; T v �TC 66.51 _DATED; JANUARY9 2019 _ ` �4 - PROTECT IN PLACE EXISTING FIRE HYDRANT PER IMPROVEMENT /'J P 66.6 ' - a 1 ''" Tb�66 94 PLAN 6745-I. a �� /END CURB �C 66.80 w� v� _ EXISTING STORM DRAIN GRATE TO BE REMOVED. 'PROP WALL 1 _ 6 - EXISTING STORM DRAIN TO BE REMOVED. SEE ROUGH GRADING PLAN •� r'. ^ -. - - _ INSTALL 6" CURB PER SDRS DWG G-1. .AN 6 PROFILE FOR PLAN "�._ r - _^. - \ AND PROFILE REVISED EASEMENT F �`" �""-- ,,:-'�' � � 0 � - ACCESS WALKWAY AND APPURTENANCE PER " e VERTICAL PUBLIC ACCESS R - DETAIL, SHEET H2 CC ji ^ TC 66.56 , �'6,-• +. �dC 66.16 ORIGINALLY RECORDED AS � IRREVOCABLE OFFER TO ', I `+ EC t .A GB - DOC. 2000-0615532 16 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, SHEET 2. PY- DEDICATE OPEN SPACE �yy,, II a ��� TC BC.03 DATED NOVEMBER 13. 2000 �/� TO WEST .EASEMENT, REC'D T.,A$ri qk, �.. ^,,,'... _ _ _ �1J NO NOVEMBER 13, 2000 AS EP 66.28d - 4' �j , CONNECT TO EXIST 2;^ `4 ��� TC65.57 - FILE NO. 2000-0615531 EC i 18" SD, IE 5485 �_\ y_ - TL''' O.R. CERTIFICATE OF I `.l `, K 1"`„`""` �� GB ` _ 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE ACCEPTANCE RECORDED �. �. 't t DETAIL SHT 2R ` 4t),� �+. (TW 66.00) FACILITIES FOR ADA ACCESSIBILITY COMPLIANCE. AUGUST 4, 2015 AS \�� I ` ` 8 4 _ �-' , OR 65.16 r3 - _ TC 66 25 ^ - �^ - W 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE % a' - Be ��;.. CABLE BARRIER PER SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. INSTRUMENT N0. t -_ _� IE 61.00 CAPE R TC D 2015-0410851 OR. 1. \5 �' d ,, EP EC.80, \ ,��� E 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS 1 '^go- LANDSCAPE PLANS r , t1, W I 4 65 99 ARE SHOWN ON THE LANDSCAPE PLANS. I KKK Y ; e ° TC 65.76 J ` EMERGENCY ACCESS EASEMENT LE \ - �' PER CERTIFICATE OF CORRECTION TO MAP 18587 RECORDED AS DOC 2019 0117080 DATED: APRIL 02 2019 Y r' �) 1 C 20 a .a 7 !% I ? - BC - 7 .. °..� 'L�a.-'TC 64.95- ' X , 1 �L EMERGENCY ACCESS EASEMENT PER CERTIFICATE OF CORRECTION TO MAP 18587 RECORDED AS ff`�'DOC. 2019-0117080 t� DATED: APRIL 02, 2019 _ 4 yy m _ Q t � t r I � 1 4 d 4 N / \v REVISED IOD EASEMENT FOR LATERAL PUBLIC ACCESS \� -iF ORIGINALLY RECORDED AS I I I , ;=" DOC. 2000-0615533 EP 64.88 "' DATED NOVEMBER 13, 2000 1 GB A ° 1 l I ' � 1 - ( ^ . ` v'. 1 4° / CONNECT TO EXIST SI C IRREVOCABLE OFFER TO DEDICATE yY'} OPEN SPACE EASEMENT. RECD I - 18" S PER ( :'CLEAN OUT, IE 58.09 5, DETAIL SHT 2 NOVEMBE{q{ ly 2000-061 531 O.R. .. FILE ... OR 63.61 L7 6 2000 0615531 O.R. CERTIFICATE OF IE 58.20 P /,y(t ACCEPTANCE RECORDED AUGUST 4, _ TA ,i 2015 INSTRUMENT NO. c , E 64 2075 410851 OR. I I .. -Be 0 EP I PLAN VIEW H xy [H, i m�:r� H:a.T„ • �:rr� �y a x6 N gl:l'dIIIIIIII �I :.. • • ,:.. I .J. OR , , 1; WA - • - - DATE: a RICE. NO.: 58007 1. /30/20 -- cl-INTONE. HALE DATE r •ra -. L_ . .VERTICAL .: ,1 :: -- -�&"I � rml Il l!SJ-.1)CV]YNIT]LiJJIl1'a9FreT.fY3:)• i GB EC ° EC �4 CONNECT TO EXIST/ �C 8518 18 SD, IE 5290 4 �t Be i d �7 364 ;TC 6503 ^', GB EO R ��4P DETAIL SHT 2.-�., ^4\ n IE 60.00 m It '\ 10 0 10 20 30 INN SCALE 1" = 10' BSMT FF=45.67 ���o�i1���������ti4����2��x - b �all- 1 U xy z m Ore1atE0 KEY MAP o m Zc <� mo DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. i DOI ue AP OVEIJ GRADING PLAN FOR: wy ENCINITAS BEACH RESORT z o PRECISE GRADING 14083-G �o . 1 EDWA D 1 ER ApN: 216-041-26 mo DATE t PLANNING CASE NO: TPM-89-014 18-257 SUBC SHEET 7 OF 25 �<F LDEV-011233-2018 r, E R i 4 3; 1 4K� PATTERNED DECORATIVE CONCRETE `C PER LANDSCAPE PLANS EP 64.48 BC 6 > 64 >r i 7 C s EP 6447 r � 1 PCR EP�64.37 e REVISED IOD EASEMENT FOR =Y�\ LATERAL PUBLIC ACCESS -\\, ORIGINALLY RECORDED AS 1 EP 64.23 DOC. 2000-0615533 PRO DATED NOVEMBER 13, 2000~ I E .14 K EASEMENT TO THE PUBLIC, PUBLIC \ PATHWAY AND BEACH ACCESS, 1 I' REC'D JUNE 7, 2000 AS FILE NO. I P 64.0 I I 2000 0299890 O.R. x EC, GB IRREVOCABLE OFFER TO DEDICATE I 18 5 SO CB P `" \ OPEN SPACE EASEMENT, REC'D DETAIL SHT 2 j \NOVEMBER 13, 2000 AS FILE NO. OR 63.31 j 20OG-0615531 O.R. CERTIFICATE I IF I 59.48 OF ACCEPTANCE RECORDED j AUGUST 4, 2015 AS INSTRUMENT Y NO. 2015-0410851 O.R. 1 \,I EMERGENCY ACCESS EASEME T � PER CERTIFICATE OF CORRECTION 1 TO MAP 18587 RECORDED A DOC. 2019-0117080 DATED: APRIL OZ 2019 18" SD g PER 1} OR 62.AIL HT 2� L: 7 OR \ �IE 59.8 v � 5 1 V ) i. IRREVOCABLE OFFER TO DEDICATE OPEN SPACE EASEMENT, REC'D f I / I FS NOVEMBER 13. 2000 AS FILE NO, 1 I t 2000-0615531 O.R. CERTIFICATE OF I. ACCEPTANCE RECORDED AUGUST 4, 2015 AS INSTRUMENT NO. 12015-0410851 O.R. 4- PROPOSED GAZEBO NOT I BUILT REMOVED I J FROM SCOPE. CHANGE NO. I DESCRIPTION I APPROVED I DATE SEE SHEET 7 1 1 1 A n . /hURUANVAAAAAU� FS d _ g °t d � a t sEP 63.99 EC, G8 I! f � I 20' ' ° I CONNECT TO E%IS 3 1 18" SO, IE 591: 6 K° 1�4 5 rn 6 dry °7 L3 = e CONNECT TO EXIST 15" SD, IE 59J1 EP 63.53 GB d� a EP 633.33 a 1 ° {{ d C a N ° o ° F86346 d 1. GB / 18 SD DETAIL 51 OR 63.56 i IE 60.28 Vr I x 62 I I AS 02, i � P1Z5 �NpE P7" ° 'I FS 67. 0. d. ,y FS 67.00 a B .05 � 7.00- 4 °F - 700g1 e d ° TW 67. ° d ° a PROP WALL 13 II - SEE SHEET 19 FOR 1 PLAN AND PROFILE ° " F 6390 -^ POOL DECK FA'e d -SEE LANDSCAPE °6d PLANS FOR DECK J J« a DRAIN LOCATION « a ° - AND ELEVATIONS Tw sza ° FS 6 d 4 / ° d ° l a a _.M 1 SO 8 R ° d > " DETAIL SHT 2 IR 61.93 GQ.. IE 59.38 FS 6 0 ° t POOL d '- 18" SO PE ° DETAIL SHT 2 12" SD C8 F OR 61.92 W 6700 - �' DETAIL SHT IE 9 72 - 1 " �� ° OR 69.50 PROP WALL 14 IE 63.08 -' S 6 " SEE SHEET 19 FOR y . FS 6710. ° PLAN AND PROFILE - a CONNECT TO EXIST. STUB PER ° ROUGH GRADING PLAN, IE 60.20 �,' F 7.0 �iFS 83.45 FS 67.11 Lt -FS 6 64.660 4I p a FS 67 4 Sf" TW 67.00 TO 65.23lq 8.01 % � TO PROP WALL 11 "6 . TW 79.00) 18 12 TO 7 TP 28 TO 7 TO 67.2 1 Tom' 7 SEE SHEET 18 FOR YT PLAN AND PROFILE PERMANENT SHORING �t } ` PER ROUGH GRADING \1 PLANS NO. 6394-G y PLAN VIEW SCALE 1 10 SCALE AS -BUILT "" VIH PLANS PREPARED UNDER SUPERVISION OF HORIZONTAL: 1"=10' //°*'2LFln� �/7F.C/� DATE: 4/A/4 CLINTON E. HALE DATE VERTICAL N/11 R.C.E. NO.: 58007 4-1-21 MARK L. HENNING E P - uriu EXP.: 06 /30 /20 IE AIL SHT 2 64.87 ,GR 69.50 JE 62.39 W.N1 GRADING DAYLIGHT DP WALL 10 SHEET 18 FOR v-- AN AND PROFILE --" PRIVATE STORM DRAIN DATA TABLE LENGTH I BEAPINGIDELTA RADIUS SLOPE DESOWPTIOM L1 81.14' S8916'36"E - 2.70% 10" HOPE PVT SD* L2 40.80' N85'37'29"E - 19.20% 10" HDPE PVT SD* L3 34.47' S77051'05"W - 1.00% 8" HDPE PVT SD* L4 35.86' S3007'20"E - 1,00% 8" HDPE PVT SD* L5 29.13' S52054'02"E - 1.50% 8" HDPE PVT SD* L6 17.18' S81'40'58"W - 1.54% 12" HDPE PVT SD* L7 17.59' N7031'05"W - 1.00% 10" HOPE PVT SO* LB 11.89' S0629'32"E - 2.00% 6" HDPE PVT SD* L9 12.32' N89'30'28"E - 2.00% 6" HDPE PVT SD* L10 1.58' NO'43'24"E - 2.00% 6" HDPE PVT SD* *HDPE PER AASHTO M252 & M294 WITH WATER TIGHT JOINTS CONSTRUCTION NOTES INSTALL 6" DECORATIVE P.C.C. OVER 5" CLASS 2 AGGREGATE BASE COMPACTED TO 95% PER ASTM D1557. FINISH PER LANDSCAPE PLANS. O - PROTECT IN PLACE EXISTING STORM DRAIN PER GRADING PLAN 6394-G. O3 - PROTECT IN PLACE EXISTING WATER LINE PER IMPROVEMENT PLAN 6745-I. ®- PROTECT IN PLACE EXISTING FIRE HYDRANT PER IMPROVEMENT PLAN 6745-I, O5 - EXISTING STORM DRAIN GRATE TO BE REMOVED. O6 - EXISTING STORM DRAIN TO BE REMOVED. INSTALL 8" DECK DRAIN PER DETAIL, SHEET 2. 12 - INSTALL 5' WIDE SIDEWALK PER DETAIL, SHEET 2. 16 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, SHEET 2. NOTE: 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR ADA ACCESSIBILITY COMPLIANCE. 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. 10 0 10 20 30 II 0 SCALE 1" = 10' DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERV APPROVED- GRADING PLAN FOR: 0ENCINITAS BEACH RESORT EDw ER PRECISE GRADINST _ APN: 216-04T-126 DATE hm PLANNING CASE NO: TPM-89-014 18-257 SUBC KEY MAP 14083-G LDEV-011233-2018Y LD EV-011233-2018 NO.I DESCRIPTION 90-T975511 1•ZTid SEE SHEET 5 PLAN VIEW SCALE 1' = 10 SCALE AS -BUILT HORIZONTAL 1"=10' 1eIZ,' �/p�g�j� rLr�rva rrt�r Hr«u urvurr< �u5; r DATTE:E: 2/Z7 27 CLINTON E. HALE DATE VERTICAL: HL R.C.E. NO.: 58007 . 11 E R INSP . O 4-1-21 MARK L. HENNING E%EXP.:06/30/20 I R GINEER ENGINEERING DIVISION APPROVALS AP OV D: ' ` - l�.J �{ , -lv- `CL EDWA ER lD DA E CONSTRUCTION NOTES W2 - INSTALL 5' SIDEWALK PER DETAIL, SHEET 2. W 6 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, SHEET 2. INSTALL ONE FOOT WIDE CURB CUT AND PCC APRON, 'n DIRECT RUNOFF TO BROW DITCH. RETAINING WALL PER ARCHITECT PLANS. W �W V L NOTE: 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR ADA ACCESSIBILITY COMPLIANCE. 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. N O D r m II 0 10 0 10 20 30 M SCALE 1" = 10' CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT 4DING PLAN FOR: ENCINITAS BEACH RESORT PRECISE GRADINR , APN: 216-04t-26 �z ow <'o Q d.N DRAWING NO. z o K U N Z 14083-q 5_m - wn� o .. SHEET 10OF 25 r LDEV-011233-2018 f'. EXIST 12" SO TO REMAIN o CONNECT TO EXIST SO / i CLEAN OUT, IE 11.71 IN r / Elf If If 1 - SD CO PER }( TIf DETAIL SHT 2 ��- li IS 11.84 INN NiN t TW 16.67 If FS 1481 TW 19 33 x 14.3 PROTECT IN PLACE EXISTING t 12"X12" GRATED INLET (OR 14.3t) SEE INFILTRATION TRENCH) FFFFFF DETAIL . THIS SHEET I END CURB. GRADE ADJACENT LANDSCAPE AREA TO ALLOW DRAINAGE TO ENTER FROM WALKWAY G \` d. ° FS 14.97 T �\ FS 1502 if d `I h IPROP WALL 9 h 11 �� SEE SHEET 17 FOR PLAN AND PROFILE 5 IF TW 17. ' TG 1Q `\ a \\ EXIST 8" SO TO REMAIN ' SD CB PER \DETAIL SUIT GR 1700 IS 1230 1\ 1-x C `� EL ROP III EXISTING RIP RAP REMOVED \ DETAI PER RIP RAP REMOVAL'E TH PLAN ACCEPTED ON \\ BAS FEBRUARY 10, 2021 k / I\SEE SWWA m GB. BOA FOR DESIGN 4 = 154 SF C 986,E VI p v' i 1 �N I Lf RINPRAP REMOVED UNDER SEPARATE TEMPORARY BEACH RIP RAP REMOVAL A REA A ENCROACHMENT PERMIT #PROW-014537-2021, PURSUANT TO CDP #5-92-203. CONDITION # 13. NOT SHOWN ON PLAN VIEW ( ) ACCEPTED FEB. 10, 2021. SHOWN FOR REFERENCE ONLY. SCALE 1" = 20' NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS BUILT 4-1-21 DESCRIPTION: PT N0 22 STA OSB-022 PER ROS 17271 LOCATION: ED. 2" IRON PIPE AND DISK IN AC PATH. NORTH SIDE OF LA COSTA AVE. AT HORIZONTAL- 1_10 VERTICAL: d($ WLCAN AVENUE 1S OFT SHOULDER CRYY}Il cuttu ceu rornn rrvwry - - - - IF ®MMM �\ FF\LT1.7 \ _ \ TW 22 24" X 2plip CAT O0HH BASIN WITH STEEL GR1<TE. NO DOME GRATE. OR I 1 EXISTING GROUND _ - BOTTOM OF BASIN * .v.r5 I ( ELEVATION = 14.0 18" CATCH BASIN WITH ATRIUM TIO INSTALL MEDIA LAYER A-1 BIORETENN SOIL GRATE, SEE DETAIL ON SHEET 2 MIX #BA OR APPROVED EQUAL (1.5- THICK) EXTEND EXISTING 6" DIA. PVC CLEANOUT AND CAP TO 6- T,II� 'i - ABOVE MULCH ELEVATION12" HOPE PIPE TO EXISTING INSTALL FILTER COURSE 3" LAYER OF STORM DRAIN SYSTEM �'1 CLEAN AND WASHED ASTM 33 FINE ENO-FIC 1 p���, N 11V1•ALE BAS IN DETAIL LAYER AGGREGATE ASTM NO. 8SAND RSTING A "NO SC�t NOTE: FOR OFFSITE IMPROVEMENTS SEE STATE PARKS RIGHT -OF -ENTRY PERMIT: DATED: 11p DAYLIGHT EXISTING GROUND UNDISTURBED • 111 [1.1 •ii rrrr` EXIST 12" X 12" CATCH BASIN WITH STEEL GRATE. PROTECT IN PLACE. 18 _I EXISTING CONCRETE � SIDEWALK I - I I .-HINSTALL 1'_ to 2.5' CLEAN ANGULAR DRAIN ROCK E _ - - STORM DRAIN PUNDISTURBED SOIL - TRENCH BOTTOM PROTECT IN PLACE ELEVATION = 12.30 INFILTRATION TRENCH DETAIL NO SCALE MODIFIED TY r 12" 12" 1.5' X 1.5" SLOT IN TOP OF CURB AT a 5' ON CENTER C5 t o N 4" PCC WALKWAY 1 _ FINISH PER - 6° w o LANDSCAPE PLANS ¢ 2.0% (MAX) f IIIII,IIIIIall >_ CB ISER j #4 0 13" EW EF - - TAIL IS SHEET j( - - ,4. -III-III 12.1 2_I_ 3w III=_I pip.IG ,4.DD I=1 I w ;III-1 i I_ -III-I Ilo�� w FG .DD / -III III wpp� 0 FIG 14.00 I ° - wow FG 14.00 ,IF -III III; owe Syr -P arc 1s4 4 �t TW 22 90 Fs lsoo FL 21 90 11TC 20 08 ITION FftOM MODIFIED 1' CURB W DITCH TO NORMAL-,, CB, BC TYPE B BROW DITCH➢,, ET A7��� SCALE 1" = 10 AS -BUILT LJL iLZW UT: urcnw eT: cnccncu UT: ENGINEERING �^ D PLANS PREPARED UNDER SUPERVISION OF REC N /'-vyGFjrli G-/Ai' DATE: A&2& GUNTON E. HALE DATE R.C.E NO.: 58007 STE OW lei 4-1-21 MARK L. HENNING I IN EXP.: 06/30/20 DATE \` 9 14.� tj M1 I i I F TY OF ENCINITAS - DEVELOPMENT SERV IG PLAN FOR: ENCINITAS BEACH RESORT PRECISE GRADING APN: 216-041-26 PRIVATE STORM DRAIN DATA TABLE Lj LENGTH I BEARING/DELTA RADIUS SLOPE DESCRIPITION L1 42.10' S17'53'O6"E - 0.30% 12" HDPE PVT SD* L2 52.46' S26'27'48"E - 0.30% 12" HDPE PVT SD* L3 42.26' S55'2T33"E - 0.30E 12" HOPE PVT SD* L4 12.24' N31'S4'2TE - 5.00% 1 12" HOPE PVT SD* HDPE PER AASHTO M252 WITH WATER TIGHT JOINTS CONSTRUCTION NOTES O - INSTALL BEACH ACCESS WALKWAY AND APPURTENANCE PER DETAIL, SHEET 2. 16 - INSTALL MODIFIED TYPE 'B' BROW DITCH PER DETAIL, SHEET 2. 18 - INSTALL ONE FOOT WADE CURB CUT AND PCC APRON, DIRECT RUNOFF TO BROW DITCH. 30 - INSTALL NO. 2 BACKING RIP -RAP (T=1,0') TYPE 2 ENERGY DISSIPATER PER SDRS DWG D-40, D.G. FILTER BLANKET (T=1.0') NOTE: 1. THE CITY OF ENCINITAS HAS NOT REVIEWED ON SITE PRIVATE FACILITIES FOR ADA ACCESSIBILITY COMPLIANCE. 2. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED TO THE SATISFACTION OF THE DEVELOPMENT SERVICES DEPARTMENT. 3. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. 01 #3 REPAIR 24" ON 1.5' X 1.5" SLOT IN TOP OF CURB AT S' ON CENTER CENTER EACH WAY 40 u 1. a - I -III- ,5.7 ;III -I I III III -I -I lr"i I-lil GEOGRID PER GEOTECHNICAL ENGINEER SECTION A -A BEACH ACCESS WALKWAY CROSS-SECTION NO SCALE 1 0 IIII 10 0 10 20 30 UV SCALE 1" = 10, KEY MAP DRAWING NO. 140,83-4 LDEV-011233-2018 I 24 a CABLE VEHICULAR PEDESTRIAN "-------- - —�- --- 6" DECORATIVE PCC. "SEE-TAQS 42 MIN 1 CABLE VEHICULA BARRIER ° EMERGENCY ACCESS ! OR DETAILS ° SEE LANDS( E PLANS ° ROAD. FINISH PER V ° I FORDETAILS LANDSCAPE PLANS { fi" CURB e ° fi" CURB 1 NoTm 1. SEE SWOMP PREPARED BY HALE ENGINEERING DATED 02j20J2019 FOR STORM WATER DESIGN AND SIZING ON F4lE AT CYtt OF ENCINITAS. EXIST4 WALL PER �'_ �T-III I I I I 1-III I (I I (( III''-i I I ( G GRADING, 2. SEE SWMA DOC NO. �0�91__ _... NEC,'f•.02 20 y CURB 112" I ` ' I ! (I �! 6' CLASS 2 BASE COMPACTED IIII I k, III:. R' "I I' AGGREGATE _ _ I III -I (I I I �- � I I I _ _ {I III ( I IIII I I I (l 1 I I -I TO 95R_-_- .• I (WATER OUAL"/ _ _ CURB . ,' I i ' -�- PER -� ASTM D1557 - - -f II + k -II- { 40 - _ SF zN MODIFIED TYPE B 1 ! - I i ' - !BROW DITCH PER t DETAIL O SEE BEACH ACCESS A N SHEET 2 i III I' I :.� �- SEE SHEEN 2 DETALS IIi 11 I'- - �, I WALKWAY CROSS-SECTION q--' T �T�- y ON SHEET 2 ! _ -- " PVC WATER BOTTOM ELEV.36.00 11 MEDIA LAYER A-1 BIORETENTION SOIL MIX SBA OR APPROVED EQUAL 2 THICK I EXIST. I 8- PVC SEWER t III IIII '- GROUND _� FILTER COURSE 3 LAYER OF CLEAN AND WASHED ASTM 33 FINE AGGREGATE SAND-- ( G' ✓�' OVERLYING A 3" LAYER OF ASTM TONE `� ��.�. �-�-,w �- - -___--§Eg --- _ _ _ ,a.� - �! DRAINAGE STONE (ASTM �57 OPEN -- � - -" A I y� SEE SHEET 3 GRADED STO NE OR EQUAL) , f E NO SCALE I I "� BOTTOM 0 GRADE BASIN ELEV. 27.0 1 EE "••1 A _ \ROUGH -. BOTTOMOF AVEL LAYER YF it ..-__- {! I ' : !.' IIi� �: i i(- (}j-�([,,_jj 1 T14+=7T1�T� OVE EXIT TOP 6" OF {{} DE OPERATIONS FROM ROUGH SCARIFY SUBGRADE -- _--.-__ --MODIFIED TYPE'B' -__.-- BROW DITCH PER DETAIL ON SHEET 2 ! PROP. WALL 3 SEE SHEET 14 _ ----- _ ____ u ___-.___-__-- _- .-j_..�.____�..v-j._ _ _ CABLE VEHICUL, EEDE$J$IAN BARRIER SEE LANDSCAPE PLANS 1 ° 6" DECORATIVE PCC _ { FOR DETAILS EMERGENCY ACCESS ROAD, FINISH PER e LANDSCAPE PLANS 6" CURB - fi" C RB °. 1 �-{- �.___._.-__ _. __.�- �__.'_-_..__-._-_�` - ---� - PROP. WALL 2 PER v - f - " y'� �T 50 - DING. ROUGH GRADING, r DWG. NO. 6394-G ...... - ...:..:.. ......... - 11 �, +<^:'- .,_ �.. y { I III { I I I f • �:� T 6" CLASS 2 AGGREGATE I II{ _- III {II II II ri EXIST. BASE COMPACTED TO 95% ��� �lil II� ji!- y y - 1- (GROUND PER ASTM D1557 - f I 1 �._ : III- III I ' I I !i j 1- •. • I �_ 1 'PVC WATER { - �� / 24" SD III l'� {I - ,�/� 'tV __�-a-__.,40 I �- III 7 8" PVC WERE j } TT' ,.III 10' FOOTING SETBACK MIN. TN' SeC po B- 6" CURB 12" CURB (SEE SHEET i MODIFIED TYPE 'B' rtBROW �• x; { NO SCALES) 1 ' DITCH PER 7 SEE BEACH ACCESS -DETAIL ON SHEET 2 WALKWAY CROSS-SECTIONON SHEET 2 I I�/� -- - -_ I 1 _�fj/� 1 ! I CHANGE NO. DESCRIPTION APPROVED DATE I BENCHMARK SCALE AS43UILT ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. M AS BUILT a-1-21 DESCRIPTION: PT NO22STA09E-022PER RX;IZ LOCATION: FD. Y IRON PIPE AND DISK IN AC NORTH SIDE OF LA COSTA AT HORIZONTAL: i"=l0, ,`y� � � ir✓ PLANS PREPARED UNDER SUPERVISION OF DATE: Z7 RE C D: APP V �-� GRADING CROSS SECTIONS FOR: ENCINITAS BEACH RESORT 14083-G PATH. AVE CLINTON E. HALE DATE PRECISE GRADING - - WLCAN AVENUE 13' OFF SHOULDER RECORD FROAk SAN DIEGO COU VERTICAL: (� R.C.E. NO.: 58007 STE WA '4� (� EDWARD ER APN: 216.041.26 4-1-21 SHEET12OF 25 ELEVATION: 62.949 DATUM: NAW BB DATUM: H MARK L. HENNING EXP.: 06 30 20 DATE DATE PLANNING CASE NO: TPM-89-014 18-257 SUBC E R INSPECTOR SENI K ENGINEER N U z Z S- w KZ N O ZF Q� zo w z z� 5Zp w0 LDEV-011233-2018 of N Y N n OU 75 70 65 60 55 50 45 40 35 30 OV 75 70 65 60 55 50 45 40 35 30 9+90 10+00 10+10 10+20 10+30 10+40 10+50 10+60 10+70 10+80 10+90 11+00 11+10 11+20 11+30 11+40 11+50 11+60 11+70 11+80 11+90 12+00 12+10 12+20 12+30 12+40 12+50 12+60 12+70 PRORLE: WALL 3 (CMU) SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 23. DETAIL 9 I --.•. .-I PROPOSED STORM I 10 0 10 20 30 SCALE 1" = 10' NO. I DESCRIPTION I APPROVED I DATE I BENCHMARK I SCALE HORIZONTAL: 1"=10' VERTICAL: VA PLAN: WALL 3 (CMU) SCALE: 1"=10' DATE: oWX ;r R.C.E. NO.: S8007 MARK L. HENNING EXP.: 06/30/20 NOTE: 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. APPROVED: RETAINING WALL PROFILES FOR: aj -' ENCINITAS BEACH RESORT 14083•13 �EDM J. M ER PRECISE GRADING _ _ APN: 216-041-26 DATE PLANNING CASE NO: TPM-89-014 18-257 SUBC SHEET14OF21 LDEV-011233-2018 NO. 10 0 10 20 30 SCALE 1- = 10' DESCRIPTION I APPROVED I DATE /V 65 60 55 50 45 40 i g FINISH SU RFACE BACK OF WALL f E � ' ♦4 00 vl Y Y •� N O o�� _ _. � FACE OF FINISH SURFACE AT WALL V 5 0 5 0 5 0 9+90 10+00 10+10 10+20 10+30 10+40 10+50 10+60 10+70 10+80 PROFILE: WALL 12 (CAST -IN -PLACE) SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22, DETAIL 2 BENCHMARK SCALE AS -BUILT PT NO 22 STA Os%-022 PER ROS 17221 PLANS PREPARED UNDER SUPERVISION OF . 2' IRON PIPE AND DISK IN AC HORIZONTAL 1"=10• ��g�Z[ DATE: 7/27/M SIDE OF LA COSTA AVE AT n� CLINTON E. HALE DATE IE 13' OFF SHOULDER R.C.E. NO.: 58007 SAN -DIEGO CWNTY VERTICAL y($ M&I4-1-21 MARK L. HENNING 2949 DAIDM: NAVD 88 �n w N a ruriNrra EXP.: 06/30/20 NOTE: 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT App OVE : _ RETAINING WALL PROFILES FOR: ENCINITAS BEACH RESORT Eo v�A 11F MER PRECISE PRADINQ,• w APN: 216-041.26 DATE PLANNING CASE NO, TPM-89-014-18-257 SUBC`:" �o p rcci N Z Q ON Q d.N F DRAWING NO. czo= U w�� 14083mG z6N W p W SHEET750F29 �� -011233-2018 10 0 10 20 30 SCALE I" = 10' NO. N a� 90 85 80 75 70 65 60 ��'t3.6S71Q�.•gi�S�S��CPr'�GSG'Z�.'1L'3595®�sl�l�i�6G�s�aeQ'J',� a� 90 85 80 75 70 65 60 9+90 10+00 10+10 10+20 10+30 10+40 10+50 10+60 10+70 10+80 10+90 11+00 PROFLEI WALL 7 (CM) SCALE: 1°=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 23, DETAIL 9 SCALE �A—S43UUILLTT HORIZONTAL: 1"=10' !//�*� L•/'VwCL� CLINTON E. HALE DATE VERTICAL: N/A PLAN' WALL 7 (CW) SCALE: 1"=10' DATE: R.C.E. NO.: 58007 ARK 1. HENNING EXP.: 06/30/20 ENGINEERING DIVISION APPROVALS IIyAW€ D: APPaOVFp:,, r NOTE: 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT 2ETAINING WALL PROFILES FOR: ENCINITAS BEACH RESORT PRECISE GRADING r APN: 216-04f-26. _ PLANNING CASE NO: TPM-89-014 18-257 SUBC N Urn ? U w z su WEI ww< ow aro � N :DRAVWJNGNO.owo�U �N SHEE -011233-2018 N NO. JO 30 25 20 15 10 5 0 ao 30 25 20 15 10 5 0 9+90 10+00 10+10 10+20 10+30 10+40 10+50 10+60 10+70 10+80 10+90 11+00 11+10 11+20 11+30 11+40 11+50 11+60 PROFILE: WALL 8 (CAST-N-PLACE) SCALE: 1'=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22, DETAIL 12 RNSH GRADE orn rio aio oin oM 0 6ci + + - rn oaf m 03 o c + p3 ayq To I EXISTING G ADE AT FACE OF WALL "1 rn n n + i__. .... I I -f" 10 0 10 20 30 SCALE 1" = 10' DESCRIPTION JV 25 20. 15 10 5 0 Jv 25 20 15 10 5 0 9+90 10+00 10+10 10+20 10+30 10+40 PROFILE WALL 9 (CAST -IN -PLACE) SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22, DETAIL 12 GRADE T BACK OF ALL o+0 LEASTNG o •o $ FIN SH GRADE I o o}} NT OF WALL-tO o $, p� +ry N /� rl m � CAST -IN -PLACE WALL .— CONNECT WALL DRAIN , _ - _- ? FINISH TO MATCH EXISTING '� TO STORM DRAIN 4,.ON SITE RETAINING WALLS - _ r, 10+60 -10+70— o+Bo o _. 10 ,- W �:-✓�-a`�" FACE OF PR '11+20-'F..'f -... -c ,,/f =A0+� WALL 8 r`"^-- 11+3p,.,. _ .� a-' i / - FACE OF PROP CAST -IN -PLACE WALL i "-11+q0 „/ \ WALL 9 F FINISH TO MATCH EXISTING ON -SITE RETAINING WALLS I 1 \ WALL DRAIN THROUGH ! 9 � v CURB jj t If X PLANT WALL 8 (CAST -IN -PLACE) PLAN: WALL 9 (CAST-N-PLACE) SCALE: 1"=10' SCALE: 1"=10' SCALE 1p. VVf4SSl h NOTE: ' 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS. r: ARE SHOWN ON THE LANDSCAPE PLANS. ° � JR Tsi1Z`• DATE BENCHMARK SCALE AS -BUILT "" "" -1-21 DESCRIPTION: PT Na 22 STA CLSB-022 PER ROS 17221 AC LOCATION: ED. 2' IRON PIPE AND DISK IN PATH NORTH SIDE OF LA COSTA AVE, AT HORIZONTAL: 1"=10, VERTICAL N[@ - �' PLANS PREPARED UNDER SUPERVISION � OF � DATE: �d7 R.C.E. NO.: 58007 MARK L. HENNING / EXP.: 0673D/20 CLINTON E. HALE DATE - WER LGAN AVENUE 13' OFF SHOULD RECORD FROM: 9SAN49 OlEGO COUNTY ELEVATION: 6 DATUM: NAVD 6� - 4-1-21 O S N IN R ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS -DEVELOPMENT SERVICES DEPARTMENI DRAWING NO. D APP OV D: RETAINING WALL PROFILES FOR: G� ENCINITAS BEACH RESORT 14083-G PRECISE GRADING OWAN ,� EDWAR - MER APN: 216-041-26 l 0 DA PLANNING CASE NO: TPM-89-014 18-257 SUBC IHEET17.OF 21 LDEV-011233-2018 N !if 15 r NO. II, III 85 80 75 70 65 60 FINISH GRI DE BEHIND Ap�LL 0O min N M M. IN 6 ,N N OI fO N N n - _••_• h n-i +onn + + o+ ; ++ +n� . m O„WNN nn VICE 6 FINIS SURFACE A FACE OF VLL III, III 85 80 75 70 65 60 9+90 10+00 10+10 10+20 10+30 10+40 PROFLE: WALL 10 (CMU) SCALE: f=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 23, DETAIL 9 PLAN: WALL 10 AND 11(CMU) SCALE: 1"=10' 10 0 10 20 30 iiiiiii SCALE 1' = 10' 03 FINISH SURFACE AT m o 00 FINISH SURFACE AT NORTH FACE OF WALL -o o SOUTH FACE OF WALL (POOL DECK) n 80 — 80 75---- 75 70 70 , 65 65 888 ci o NISH SURFACE AT o N g n 60 0 wAtt-+ sptu-- �_._-_ 0 POOL DECK) ? +o�� 55 -FINISHI--SD ACE -AT.__ _...__ _.-__._-- 55 OUTH FACE OF WALL 50 50 9+90 10+00 10+10 10+20 10+30 10+40 10+50 10+60 10+70 PROFLE: WALL 11 ON SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 23, DETAIL 9 DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT UrtHvrry or UNLo or 4-1-21 DESCRIPTION: PT Na 22 STA cLm-M PER ROS n2n LOCATION: ED.2 IRON PIPE AND DISK IN AC PATH. NORTH SIDE OF LA COSTA AVE. AT HORIZONTAL: 1 =10 VERTICAL: _ //A/ Ad,/ � � PLANS PREPARED UNDER SUPERVISION OF DATE: s�9 R.C.E. NO.: 58007 MARK L. HENNING EXP.: O6�i�Q/20 DATE CLINTON E. HALE DATE HALE - AYENU€ 13' 4LE SHO LU DER RECORD FROAh sAN DIEGOcoUNn _ ELEVATION. 52949 DATUM: NA)M 88 4-1-21 R I PEC OR NI IN i 8� } I 8( 7` A Z 6` PL EX STING SITE WALL 2.6' EXISTING GRADE PERMANENT SHORING PER ROUGH GRADING PLANS NO 6 94-C _ loi� g0':; RETAIN NO WALL 11 POOL DECK W WAY RAMP NEW WATER MAIN SGASEC nON1 F-F VERT NOTE: 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS ARE SHOWN ON THE LANDSCAPE PLANS. Z�jQ oN Z o N APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. y o ROVED- RETAINING WALL PROFILES FOR: EEO z x ENCINITAS BEACH RESORT PRECISE GRADING 141063-rA o W e EY "u APN: 216-041-26' 0 PLANNING CASE NO: TPM-89-014 18-257 SUUC SHEET 18OF25 wa „ `ZZ; LDEV-011233-2018 t- 80 75 70 65 60 55 50 45 bu 75 70 65 60 55 50 45 9+90 10+00 10+10 10+20 10+30 10+40 10+50 PROFILE: WALL 13 (CMU) SCALE: 1-=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22. DETAIL 2 NO.I DESCRIPTION PLAN: WALL 13 AND 14 (CMU) SCALE: 1"=10' 80 — 75 70 65 60 55 50 45 80 75 70 65 60 55 50 45 9+90 10+00 10+10 10+20 10+30 PROFILE: WALL 14 (CMU) SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22, DETAIL 2 I�mss=E- I ,G SCALE: 1" xi0' L 10 0 10 20 30 SCALE 1" = 10' APPROVED DATE BENCHMARK SCALE AS -BUILT wv 4-1-21 1 DESCRIPTION: PT Na 22 sTA a.% -oat PER Ros 17271 LOCATION: E12 2" IRON PIPE AND DISK IN AC PATH. NORTH SIDE OF LA COSTA AVE. AT • HORIZONTAL: 1"=10 VERTICAL: N/$ *+ ' ?rn � Ak �`� PLANS PREPARED UNDER SUPERVISION OF PATE: ¢h3/iy R.C.E. NO.: 58007 MARK L. HENNING EXP.: 06/30/20 CLINTON E. HALE DATE - 1M1l1 BAN AVENGE 13- OFF SHOULDER RECORD FROM: SAN DIEGO CODNTY ELEVATION: 62,949 DATUM: NAmp ao 4-1-21 - IN N EER SHORING WALL PERK 75 70 65 60 55 50 45 40 75 70 65 60 55 50 45 40 9+90 10+00 10+10 10+20 PRARI R WAI I 15 (CIP) FINISH SUR ACE AT BACK -F WALL a O O N w m m o� IL FACE Of WALL SCALE: 1"=10' HORIZ. / VERT SEE STRUCTURAL PLANS SHEET 22, DETAIL 12 a 3 p �jp FACE OF PROP BOARD FORMED CIP WALL _( -SHORING WALL] r , £ E p FINISH PER LANDSCAPE f/4Lr PER DWG NO. ARCHITE\C^T PLANS /6394 G lZ PLAN WALL 15 (CIP) SCALE: 1"=10' NOTE: i 1. THE COLOR/MATERIALS SPECIFICATIONS FOR THE PROPOSED WALLS -� ARE SHOWN ON THE LANDSCAPE PLANS. ZCT 5-0 wo Nz no a,zo rcN :ERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT :DRAWING roD: APP OV D: RETAINING WALL PROFILES FOR: Roo wENCINITAS BEACH RESORT z DWA D MER PRECISE GRADINCq .APN: 2'1"41-26,.............,..-. :__w oDA PLANNING CASE NO: TPM-89-D14 18-257 SUBG<F LDEV-011233-2018 STRUCTURAL - GENERAL NOTES GENERAL REQUIREMENTS GOVERNING CODE: The design and construction of this project is governed by the "Caldfomla Building Code (CBC)", W 16 Edition, bereaRer reerted to as the CBC, as adopted and modified by the C'Ty of Encinitas, CA un- derstood to be Me Authority Having Jurisdiction (AHJ). REFERENCE STANDARDS: Refer to Chapter S5 of 2016 CBC. Where rimer Standards are noted in the draw- ings, use he latest edition of the standard unless a Specific date is indicated. Reference to a spectik section in a code dam not relieve the contractor from compliance with the entire standam. DEFINITIONS: The following definftions cover the meanings of cerise terms used in these notes: 'Archi ectrEngine si The Architect of Record and the Structural Engineer of Record • "Structural Engineer of Record' (SER) - The structural engineer who is licensed to stamp & sign the structural documents for the project- The SER is responsible far the design of the Primary Structural Sys- tem. • 'Submit for recall - Submit to the AmhitecHEngineer far review prior to fabrication or construction. 'Per Plan' - Indicates references to the structured plans, elevations and Structural general notes. • "Specialty Structural Engineer' (SSE) - A pmfeasdonal engineer (PE or SE), licensed in the Slate where the project is local (typically not the SER), who pedoons specialty Structural engineering services for Selected specialty engineered elements identified in Ne Contract Documents, and who has experience ant training in the Specialty. Documents scrimped and signed by the SSE shall be completed by or under Me direct supervielon of the SSE. "Bidder -designed" - Components of the structure Net require tM general contractor, subcoMador, or supplier "a is responsible for the design, fabrication and installation of warciatiy-engineered adamants Identified in Me Contract Documents fa main the services of an SSE. Submittals of'Bidder-designs ele- ments shell be stamped and s el by the SSE. SPECIFICATIONS: Refer to the project specifications sound as pad of fie contract documents for Information supplemental to these drawings. OTHER DRAWINGS: Refer to Me architectural, mechanical, electrical, civil and plumbing drawings for additional information Inctudlng but not limited to: dimensions, elevations, slopes, door and window openings, non -bearing walls. stairs, finishes, drains, waterproofing railings, curtain walls, elevators, curbs, dimensions, mechanical unit Indefinite, and other constructurel items. STRUCTURAL DETAILS: The structural drawings are intended to show the general character and extent of the project and am net intended to show all means of the work. Use entire detail sheets and specific details referenced In the plans as'Typical' wherever they apply. Similarly, use detalls on entire Shoals with "typical" in the name wherever they apply. STRUCTURAL RESPONSIBILITIES: The structural engineer (SER) is responsible far the strength and stability of the primary stmdure in its completed farm. COORDINATON: The Contractor Is responsible far coordinating details and accuracy of the work; for confirming and careful all quantities and dimensions; for Salentine fabrication procesaea; for techniques of assembly; and far performing work in a sate and swum manner. PRE -CONSTRUCTION MEETINGS: The Contractor is responsible for demanding pm -construction meetings prior to commencing work. Pre -con meetings, scheduled approximately two weeks color W the start of the relevant work, are requiretl for me fddowing phases of construction: Poet -tensioned slabs, Concrete, Wood Framing. Attendees for pre -construction meeting am to include contactor, relevant subcontracers, fabricators, inspectors, arohgectlengineeq and nepreseitativeofthe Authority Having Jurlsdictia where required Meefingagendasareto include review 0 the work snipe, project schedule relevant to the work, contact information d responsible parties, Inspection peims, review of materlads and any special caws or Issues, procedures for publications if required, rest- ing and acceptance, etc. MEANS METHODS and SAFETY REQUIREMENTS: The contractor is responsible for the means and methods of construction and all jab mated safety standards such as OSHA and DOSH (Department of Occupational Sorely and Health). The connector is responsible for means and methods of construction alleged to the intemrediae struc- tural conditions (la. movement of the structure due to moisture and thermal effects; construction sequence; tempo- rary grading, etc). BRACING/9HORING DESIGN ENGINEER: The contractor shall at his discretion employ an SSE, a registered professional engineer for Me design of any temporary bmang and sharing. Submit adnatmation sequence to Arent. tecVEngdneerfor review. TEMPORARY SHORING BRACING The contractor is responsible for the strength and stability 0 the structure during construction and shall provide temporary shoring, bracing and other elements required to maintain stability unfit the creature is complete. It us the contractors responsibility to be familiar with me work required in the con - woman documents am the requirements he executing fi properly. CONSTRUCTION LOADS: Loads an Me structure during construction shall not exceed the tlesign loads as noted in DESIGN CRITERIA & LOADS below or the capacity of par lolly completed construction as determined by the Contractors SSE far Braang/Shoring. CHANGES IN LOADING: The Samuel has the responsibility to notify the SER of any amhfiecfoml, mechanical, electrical, or plumbing load imposed onto the structure that dMrs from, a mat is me documented on the original CmdDocumen(amhlteduml/structurallm"hanicel)ek&fimplumbingdmwdngs). Providedocumenb- Lou of location, load, size and anchorage of all undocumented loads in excess of 400 pounds. Provide marked -up structural plan indicating locations of any new equipment or loads. Submit plans to the AmhotecVEngineer far m- view prior to Installation. NOTE PRIORITIES: Plan and deail notes and specific loading data provided on individual plans and detail draw- ings supplements information in the Structural General Notes. DISCREPANCIES: IO case of discrepancies between the General Notes, Si ecificalluns, Plans/Debits or Refis- ence Standads, the Architect Engineer stall determine which shall govern. Discrepancies shall be brought to the attention of the ArchitecVEngineer before processing with me wore. Should any discrepancy be found in the Con- tract Documents, the Connector will be deemed to have included in the prise the most expensive way of complet- ing the wont, unions prior to the submission d the price, the Contmads asks for a decision mom the Ambfiem as to which shall govem. Accordingly, any coMlld In or between the Contract Documents shall net W a basis for adjust- ment in the Carl Rica. SITE VERIFICATION: The wrNacta' Shall verify all dimensions and conditions at the She. Coal between the drawings and actual site candidate shall be brought to me attention of the Amhitectligi inere before processing with the work. ADJACENT UTILITIES: The contractor shall determine the location of all adjacent underground utilities prior to earthwork, international sharing, and excavation and prior to drilling hoes far piles and tieback anchors. Any utility information shown on the drawings and Saudis is approximate and net necessarily complee. ALTERNATES: Alternate products of similar strength, nature and form for specified gems may be submitted with adequate technical documentation (proper test raped etc.) to the AmbromEngineer for review. Alternate moral als that are Submitted without adequate technics documentation «that sgr i inn6y deviate from the design intent of mate Cats specHled may be returned without review. Alternates that require substantial effort te review will not be reviewed unless authorized by the Owner. SUBMITTALS SUBMITTALS of shop drawings, Product data and mill feels are required for items noted sections and far Wow designed elements SUBMITTAL REVIEW PERIOD: Submittals shall be made in time to provide a mhmmuen of TWO WEEKS or 10 WORKING DAYS for review by the Archit"VErgeneer prior to the onset of fabrication. GENERAL CONTRACTOR'S PRIOR REVIEW: Prior to submission to the ArchitectEngineer, the Contractor shall review the submwal for completeness. Dimensions and quantities are not estiewetl by the SER, and therefore, must be verified by the General Contractor. Contractor shall provide any necessary dimensional details requested by me Detainer and provide the Contractors review stamp and signature before forwarding to the Amhiteohl Engineer. CHANGE NO. I DESCRIPTION I APPROVED I DATE SHOP DRAWING REVIEW: Once the Somewhat has completed his review the SER will review the subs lal far general conformance with the design concept and the contract documents of the building and will stamp the sub- mtw accordingly. Markings or comments shall not be cormWetl as relieving the contractor from mmpllance with the project plans and specifications, nor departures there room. The SER will return submittals in the form they are submitted in (either hard copy or dectoonic). For hard copy submi Mal the contractor is responsible for submitting the required number of copies to the SER for review. SHOP DRAWING DEVIATIONS: When shop drawings (component design drawings) differ from or add to the re- quirements of the structural drawings May shall be designed and stamped by the responsible SSE. BIDDER -DESIGNED ELEMENTS Submit 'Bidder -Designed' detail submittals to the Architect and 5ER for review. The defamed submitals slash also be Submitted to the city far approval, if requiretl by the city. Design of prefabricated, "bidder designed, manufactured, pre-engineered, w other fabricated products shall be comply wMh the following requirements: 1) Design considers tributary dead, live, wind and earthquake loads In combinations required by CBC. 2) Design whin the Deflection Limits noted herein and as speal or referenced in the CSC. 3) Design shall conform to the specifications and reference standards of the governing adds. 4) Submital shall incude: a. Calculation prepared, stamped and signed by the SSE demonstrating cabe conformance. 0 Engineered component design drawings are prepared, sbmped and signed by the SSE. c. Product dab, technical information and manufacturers written requirements and Agency ap- provals as applicable. U. SSE may submit to the Architect/Engineer a request to utilize relevant enemata design criteria of similar nature and generally equirwil y which is recognized by the Code antl acceptable fa Max Authority Having Jurisdiction. Submit adequate documentation of design. DEFLECTION LIMITS FOR VERTICAL LIMIT SSE I BIDDER DESIGNED ELE- MENTS: Roof Members, Dead +Live or Snow or Wind Total Lead(TL) Deflection L1240, where (L is span length.inches) Roof,Liveor Snowor Windl.oad (RLL) LI360 Fluor Members, Total Load 01)Unix 1_/240 Floor Uvl Laad (LL)uno L1360 Wood Floor Joist Total Load H L) L 1480 Wood Floor Joists Uve Load MILL) LI600 Members Supporting Masonry L 11200 or IX max masonry, DL only Operable Partition Support Members LI BW or'r/•°Maximum SIP Panel Live Laid Deflection L 1360 HORIZONTAL LIMIT and FOOTNOTE Members Supporting BrlMle Finishes L1240 (1) Members Supporting Flexible Finishes 10r(1) MmeSupporting Masonry 7 x Cladd (1)W0 (1) Wind Load is mducibie to 0.42 Was the Component and Cladding Loads per Table 16043 remember GENERAL CONTRACTOR'S PRIOR REWEW: Once Me connector has completed his review of the SSE compo- nent drawings, me SER will review the SubmiMat for general conformance with the design of the Wilding and will stamp the submiml admiral Review of the Specialty Stuctural Engineers (SSE) shop drawings (component design drawings) is for compliance wfth design criteria antl compatibility with the design of the primary structure and does net relieve the SSE of msponsib6ity for that design. All necessary bracing, gas, anchorage, propriefary products shall be famished and installed per manufacturers instructions or the SSE's design drawings and Seldom - More. These elements include but are not limited Me • Steel Stairs • Handrails, Guardrafis and Balcony Rail Anchorages • Extenor Cladding Systems: Curtain Wag Systems, Pre-engineered Panels • Ras Mounted Component: Skylights, hatches • Facade Access Equipment Loegne Supports • Mechanical, Eecbical,Plumbing & Sprinkler Hanger Plans Temporary Shoring Systems Prefablkated Woad Roa Trussas Solid Web Wood Joists • Engineered Wood Products, (PSL, LSL, LVL) • Pre-fabricwnd wood sheer & bearing wall Panels • Wood Hold-down Systems • Open Web Wood Josts • Tapered Solid Web Wood Joists • Facede Access Equipment I Lifeline Supports • Cdd-formed Metal Studs- Exterior Wall Assemblies • Cold -formed Metal Studs - Framing Interior Walls including Radial Height Cdd-`armed Metal Studs & Joists Framing Overhead Settle • Space Frames (UniwooQ Dock Lifts • Canvas awnings • Antennas, satellfie dishes, • Storage tanks & Coal lowers • Fountain or pool structures l equipment vautis • TOeming Elements .& Supports (see section above for more info) • Facade Access Equipment) L'oeline Supports INSPECTIONS. QUALITY ASSURANCE VERIFICATIONS AND TEST REQUIREMENTS INSPECTIONS: Foundations, famous, under slab systems antl framing are subject 0 inspection by the Building Official in accordance with CBC 110.3. Contractor shall cepminate all required inspections with the BwMing Offi- cial. SPECIAL INSPECTIONS VERIFICATIONS and TESTS: Special Inspections, Verifications and Testing shall be one in acceptance whb CBC Chapter 17 and the STATEMENT OF SPECIAL INSPECTIONS herein Po®r CBC Sections 17N and 1705, as applicable. SPECIAL INSPECTION AGENCY add SPECIAL INSPECTORS: Owner shall retain to Provide Special Inspections for the project. Spacial Inspectors shall W qualified persons per CBC 1704.2.1. STATEMENT OF SPECIAL INSPECTIONS. Special Inspections and Testing per CBC Sections 17i34 and 1705 am required for the following: FABRICATION SHOP INSPECTION: Where oforite Fabrication of gravity LOAD BEARING MEMBERS & AS- SEMBLIES is performed, Special Inspector shall verify that the cbricsnr complies with CBC Sections 1704.10 and 17N 25 which Includes the following: tE n Ps O m an so 101 West Broadway, Suite 1260 San Diego, California 92101 P; (6191234-0501 www.dcirendneemmm ®rpry+gMee]OIe UAmeb Un toot. Nlagns Rmawl Poor to the sbri of fabrication, Special Inspedor(s) representing the Owner, shall vin the Fab- neators shops) where the work is to be performed, and whims that the Fabricator ma'mwns de - Wiled Fabrication and Center Control procedures that provide a basis for inspection, cultural of workmanship, matenat control and fabricator's ability to conform ke approved Construction Gocu- memo and referenced Standards. Fabricator shall have available for Inspectors review, detailed procedures for mwcFA control that demonstrates the refu sator's ability to maintain suitable records and procedures such that, at anytime during the fabrication process, the malarial specification, grade and applicable test mports for Primary load-maying members, are capable of being construed. SOILS & FOUNDATION CONSTRUCTION per CBC Section 1705.6 • Periodic inspection of soils eaMwork par Table 1705.6 is required fa: o Foofing soil bearing surfaces prior to placing any radiating steel • Excavation depth and bearing layer motto placing any rainforohng steel. • Compacted fill material classification. o Srbgtode preparation poor fa filling. • Continuous inspection per Tablets). 1705.6 required for. o Filling operations W sandy requirements of CSC Table 1705.6 and the immuchnlol report listed under SOILS & FOUNDATIONS section. o Compacted fill density tasting of each lift, proper Ind thickness and material classification CONCRETE CONSTRUCTION per CBC Seddon 1705.3 and Table 17053 including, Periodic inspection required for: • Sae & placement of all reinforcing steel and PT tendons prior te the pour. o Placement clearances amund reinfardlg steel and PT tendons at embedded conduit. • Construction and removal of formwork and restoring. • Placing & size of cast -in -place bolls and embedded fabrications prior to the pour. o Shape, location IS dimensions d members formed. Use of the required design concrete mix. o Melncnarme of specified acing temperature and techniques. o Verificafion of inaXu concrete strength prior to removal of shores and forms from beams antl sdmo- Most slabs. Continuous inspection required during the: o Placing of reinforced concrete, for proper application techniques. o Placing of concrete around cad -in -place Whis and embeds. o Sampling of fresh concrete. • Detwmime m of slump, air content and emperature. • Grouting operation m posiJnstalled bolts or tuber dowels. • PT Tendon stressing. o Grouting d bonded prestressing tendons in the seismi>force-resisting system. SOILS AND FOUNDATIONS REFERENCE_ STANDARDS: Conform W CBC Chapter 18'Sets and Foundateli GEOTECHNICAL REPORT: Readmmemafions contained In Geotechnical Exploration Encinitas Resod Hotel 2100 Nunn Coast Highway 101 Assessors Parcel Number 216-041-26-00 dated April 40 2017; and addendum letter No 1 call September 14, 2017 by Leighton were Used for design. CONTRACTOR'S RESPONSIBILITIES: Contractor shed be responsible to review the Geotechnical Report and shall follow the recommendations sperofied therein including, but not limited W, subgrade preparations, pile firra l- Iatlon Precool ground water management and steep slope Beef Management Practices." GEOTECHNICAL SUBGRADE INSPECTION: The Geotechnical Engineer shall Inspect all sub -grades and pre- pared soil bearing surfaces, prior be placement of foundation reinforcing steel and concrete. Geotechnical Eng4 Seem shall proylde a letter to the owner stating Met wile are adequate to support Me 'Allowable Foundation Be- ing Pressure(s)' shown below, Assumed values shall be field vedfled by the Building Metal or the Geotechnical Engineer poor to placing concede. DESIGN SOIL VALUES: Alessi a Foundation Baoiing Pressure. .... .._............_..4WD-55M PER Passive al Prosame........... ............... _. 350 PSFIFT Active Lateral Pressure (unms inert) ............................. 35 PSFIFT At -Rest Local Pressure (restrainetl) _ S5 PSFIFT Seismic Lateral Pressure ....... ...................... ...._......... - 12H(BH at Unrestrained Walk) Coe0 ckart of Sliding Friction ...................... .... 0.35 (6) Chloride Content Conform to ACI 318 Table 19.3.2.1. (7) Non- chloride accelerator: Non -chloride associating admixture may be used in concrete placed at ambient temperatures below 50°F at the contractors opt. (8) ACI 318, Section ISE.1.1 exposure classes shall be assumed to be FO, SO, PO, and CO unless different ex- posure classes are listed In the Table of Met Design Requirements that modify Ness one requirements. IS) Shrinkage Limit Concrete used in elevated stabs and beams shall have a shrinkage limit of 0.045% at 28 days measured in accordance coif ASTM C157. Submit laboratory test result to SER for approval prior to construdion. FORMWORK & RESHORING: Conform to ACI 301 Section 2 "Formvrolk and Farm Acceswriea." Removal of Fortes shall carders b Section 2.3.2 except strength indicated in Section 2.3.2.5 shall be 0,75 f C. Recherche shall conform to Seddon 2.3.3. Contractor shall submit formwork removal antl mshore installation procedure and draw- ings as applicable sealed by a pronounced l engineer licensed in the sire where the project is located for the SERa information. Conform to ACI 301 Section 4.3. HANDLING PLACING CONSTRUCTING AND CURING: Cartoon to ACI 301 Smash 5. In addition, her weather concreting shall conform W ACI 30SR-10 and cold weather conc nng shall conform to ACI 3MR-10 CONCRETE CURING: Provide adrg compounds far concrete as follows: ill Use membrane curing compounds that are cempatible with and will not aged surfaces to be covered with finish materials applied directly to concrete. (2) Apply curing compounds at a rate equivalent to the rare of application at which curing compound was origi- nallytested for In conformance to the requirements of ASTM C Sol and the manufacturers commensal bons. (3) Apply specified curing compound to concrete slabs as soon as final finishing operational are complete (within 2 boors and after surface water sheen has disappeared). Apply uniformly in continuous operation by power spray or roller In accordance with manufacturers directions. Ramat areas Subjected to heavy rainfall within 3 hours after initial application. Maintain con nuity of coating and repair damage during during prior (4) Use curing compound compatible with and applied most direction of system manufacturer of prorq%V% seder. (5) Apply two separate coats with first allowed to become tacky before applying second Direction of second application shall W at right angles for direction of first CONSTRUCTION JOINTS: Conform 0 ACI 301 Sections. 22.2.5, 5.22.1 and 5.3.2.6. Construction joins shall be located and detailed as an to construction drawings. Submit aftemate locations per ACI 301 Section 5.1.2.3a for review and approval by the SER inter weeks minimum prow to farming. Use of an acceptable adhesive, surface rebNant, Portland cement grout or roughening the surface is not required unless specifically noted on the draw- ings. EMBEDDED ITEMS: Position and secure in place expansion joint manquil, anchors and other Structural and non- structural embedded dams before placing concrete. Contractor shall refer to mechanics, electrical, plumbing and archgedural drawings and coordinate other embedded items. LEAN CONCRETE aACKFILL: Conto to recommendations of ACI 229R-13'Controlled Low Stmngth Materas (CLSM)' for mixing and placing lean concrete backfifl shown on the drawings. Use iib psi mix far backfill not un- derfooungs. Use 300 psi mix for Sassari blow footings. Use standard slump test to verify flow ability. Test in an cordama arm ASTM D 4832-10'Standard Test Method far Preparation and Testing of Controlled Low Strength Material (CLSM) Test Cyleders." SHRINKAGE: Conventional and poet -tensioned concrete slabs will conunue to shrink after Initial placement and stressing of concrete. Contractor and subcontractor shall coordinate lending and interior material finishes to pro- vide adequate overseas far expected stmclral (come shrinkage and shall include, but not be limited as curtain wall, dryvit storefront, skylight, flaw finish, and ceiling suppliers. Contact Engineer for expected range of shrink- age. FLOOR FINISHES: Tile contractor mud provide and correctly install an Iwlation membrane and property dubiled FOUNDATIONS and FOOTINGS: Foundations shall bear on either on competent native soil or compacted struc- expansion joints to help minimize cracking afinishes with cementitious selfino beds et finish propadias (tile, stone, tua l IS as Per the geoterchnical expert. Extends pendular futures shall bear net less then t36t inches blow finish terrazzo, concrete tapping, elm). The expansion joints shall be sized for an expected shortening movement a 0,01 grade, unless se eraise specged by the geoteMnicel engineer and/or the building official. Ancillary structures shall inches per foot. bear not hew Nan 18' below lowest adjacent grade and have an allow able bearing value of 2000 PSF. -, T .11 II,., •.,•r�.,••,.-� ne�� FOOTING DEPTH: Tops of footings shall be as shown on plans with vertical changes as indicated with steps In the footings; locations of steps shown as approximate and shall be coordinated pour me civil grading plans to en- sure Met the Solution Perimeter ooings bear no less Nan 38 inches area finish grade, or as otherwise indicated by the gwtamnical engineer or building official. SLABS -ON -GRADE: All slaws-on-gmda shall bear on compacted stmcWral fill or competent native sail per the ge- commcel repart. Ad moisture sensitive slabs -on -grade or than subject to receive moisture sensitive coal covering shall be provided with an appropriate capillary break and vapor barrieurelardanl over the subgrade pre- pared and Installed as noted in the gedechnical report, earlier manufacturers widen recommendations and mori dill with me finishes specified by Me Architect. CAST -IN -PLACE CONCRETE REFERENCE STANDARDS: Conform to: (1) ACI301-10"Spec gansfor StruOUMIConcrete (2) CBC Chapter 19'Concretl (3) ACI 318-14'Building Code Requirements for Structural Concrete" (4) ACI 117-10'Specifications for Toerances far Concrete Genotypical and Material" FIELD REFERENCE: The contractor shall keep a copy of ACI Field Reference manual, SP-15,'S undard Spece- cations ter Studded Concrete (ACI 301)wit Selected ACI and ASTM References:' CONCRETE MDITURES: Conform to ACI 301 Section 4 'Concrete Mixtures' and CBC Section 1904.1. MATERIALS: Conform to ACI 301 Section 4.2.1 'Materials" far requirements for comentidous materials, Steel plan, mixing water and welcomes. SUBMITTALS: Provide all submit required by ACI 301 Section 4.1.2. Submit mix designs for each mix in the table below. Subslantating strength results from past tests shall not be old" Than 24 Mambo per ACI 318 Section 26.4.3.1 MIT TABLE OF MIX DESIGN REQUIREMENTS Member Strength Test Age Nominal Exposure Max Air Con- te Nos Type mboution I psi) (days) Maximum Class W/C ern h to e Typical Aggregate Ratio ONO) Foofirrgs 4000 28 1" C2 - - Recurring Walls 1 4000 1 28 1' 02 0.40 - Table of Mix Design Recommence Notee: (1) WIC Ratio: Warercwoudd ions material mesa shall be based on the total weight of cementiteus materials. Maximum mites are controlled by strength noted In the Table of Mix Design Requirements and durability re- quirements given In ACI 318 Section 193. (2) CemenMious Mateme: a. The use M fly ash, other poaelans, sines fume, or slag shall conform to ACI 318 Sections 19.3 2 ant 26.4.2.2. Maximum amount of fly ash shall be 25% of total conventions content unless reviewed ant approved otherwise by SER. In. For concrete used in elevated flows, minimum cementitious-materials content shall spoken to ACI X1 Table 4.2.2.1. Acceptance of lower cement content is contingent an providing supparting data to Me SER for review and acceptance. S. Camentitious materials shall conform to the relevant ASTM standards listed in ACI 318 Section 264.1.1.1(a). (3) AS Consent Conform to ACI 318 Section 19.3.3.1. Minimum standams for exposure Mass am noted in the table. If freezing and thawing class is not noted, air content given Is that required by the SER. Tolerance is af-7==%. At content shall be measured at point aplacement. (4) Aggregates shell conform 0 ASTM C33. (5) Slump: Conform In ACI Sol Swoon 4.22.2. Slump shod be determined at point of placement. to two years arrer constructed one as a exi crsuing Will rymeany uses. i nose aeons ua nu, gP,wnr Me iintegrity of the stmcbre. However, Di recommends a one-time crack repair and maintenance program be implemented for than slabs exposed to water or chemkals. The maintenance program shall consistof: Inspect slabs and supporting members two years after consW ction • Detamimoracksini Mruc core bompalred • Repalrcracer The noel length of cracking can be estimated in a 009 feet of cracks per square feet of slab ane& The owner should reserve funds far this one time maintenance program, which is to take place two years after the completion of consumption. Evan though cracking is normal and meet olden not structurally significant, when checking occurs during construc- tion the contractor shall coned me ArchtlecMEngineer for review. The contractor should budget 0.004 it of epoxy Injected Stock repair per square four of slab. STRENGTH TESTING AND ACCEPTANCE: Tes' : Goldin samples and conduct tests in accordance with ACI 301 Section 1.6.3.2. Additional samples may he required 0 When concrete strengths at alu:mate intervals than shown below. • Cure 4 cylinders far 28-day test age Cure 6 cylinders far 28Eay test age post -tensioned concrete. Test 2 cylirm re at 2 or 3 days for poo-tensioneld concrete only, lest 1 cylinder at 7 days, test 2 cylinders at 28 days, and hold 1 Stunner in reaerve far use as the Engineer items. After till days, unless notified by the Engineer to the contrary, the reserve cylinder may be discaded without being tasted far specimens meeting 2&dlay strength requiremene. • Cure 5 cylinders for N day test age. Ter one at 7 days, one at 28 days, 2 at 56 days and hold 1 cylin- der in reserve for use as the Engineer directs. After 72 days, unless nodded by the Engineer to the con- trary, the reserve cylinder may bra discarded without being lased far specimens meeting 5I day strength requirements. • Cure 6 eygnders fa 90+Iay teat age. Test one at ] days, one at 28 days, one at 56 days, 2 at SO days. and hold 1 cylinder In reserve for use as the Engineer dinam. After 106 days, unless notified by the En- gineer 0 Me contrary, the reserve cylinder may be tliscamed without being tested for specimens meet- ing 91 strength requirements. • The number of cylinders indicated above reference 6 by 12 In cylinders. If 4 by 8 in cylinders are he be usetl, additional cylinders most be cured for testing d 3 cylinders at test age per the table of as design requirements. AcceptanceStrength S satisfactory when: (1) The averages a all sets of 3 consecutive testa Spend or exceed the enriched efrength- (2) No individual last falls below Me specified strange by mom than 500 psi. A lest' for acceptance is the average strength 0two 5 by 12 in. cylinders or three 4 by 8 incytinderstest- ed at the specified test age. CONCRETE PLACEMENT TOLERANCE: Denfarm 0 ACI 117-10 far concrete placement tolerance. REFERENCE STANDARDS: Conform to: (1) ACI 301-10'Standard Specif fs far Structural germinal Seddon 3 "Reinforcement and Reinforcement Supports," (2) ACI SP-66(04)'ACI Dia6irg Manual' (3) CRSI MSP-09, 28w Edition, 'Manual of Standard Practice ° (4) ANSVAW S of A: 200,'Strucluml WoMNg Code - Reinforcing Steel.° (5) CBC Chapter l 9Goncrete. (6) ACI 318-14 "Builtling Code Requirements far Structural Concrete." (7)ACI 117-10'Specrm ons fa Tolerances for Concrete Construction and Matimes' On DESIGNED BY'. DRAWN BY: CHECKED BY:AS-BUILT MIL TJH JWENGINEERING DNISION APPROVALS CITY OF ENCINITAS-DEVELOPMENT SERVICES DEPAFlTMENT DRAWING NOPLANS PREPARED UNDER SUPERVISION OF RECO E EPn VPt�� D APPROVED: ENCINITAS BEACH RESORT DATE:? 2i��L �.14083-G JUSTIN WEI OArR.C.E. NO.: S62B3STE AK DWARDJ. IM R PRECISEGRADNG 4-1-21 . to -1� APN: 216-041-2fi REVIEWER INSPECTOR SENIORENGINEER JUSTIN WEI EXP: 06PORD19 DATE DA PLANNING CASE NO: TPMA9014 18267SUBCrot SHEET 20 OF Z$ LDEV-011233-2018 SUBMITTALS'. Conform to ACI 301 Section 3.1.1 "Submittals." Submit placing drawings showing fabrication tl4 mensions and placement locations of reinforcement add reinforcement supports. MATERIALS: Reinforcing Bars .......... ,....... ., ...... ASTM A615, Grade 60, deftern ed bars. ASTM A706, Grade 60, deformed bars. Smooth Welded Wire Fabric ............... ASTM A185 Deformed Welded Wire Fabric.... _._ . ASTM A497 Bar Suppors........_......._....._....._...... GRSI Mal Chapter 3 "Bar Supreme.' Tie Wire__ _.__.__._.__.._................ 16 gage or heavier, black annealed. Stud Rails........ ASTM A1044 Hssdetl Deformed Sara ........... ... ASTM M70 EARTHQUAKE REQUIREMENTS: Longitudinal Bars in shear walls and coupling beams of shear walls Shall con- form to ASTM A706, Grade 60 or shall conform to the following requirements: (1) all i_ng', Welding is not pwmMed except as specibed in Me drawings. Weld in accordance wiN AWS D1.4. (2) Mill Tess: Submit milt coriflcates indicating physical and chemical properties. (3) Yield Strensel Actual yield strength, based on mill lads, does not exceed the specified yield strength by more than 18,000 psi. (Retexi shall not exceed this value by more than an additional 3000 psi.) (4) Ultimate Strength: The ratio dthe actual tensile strength to tie actual yield! Strength is not lass than 1.25.] FABRICATION: Conform to ACI 301. Sedan 3.2.2.'Fabrlcation", and ACI SP-%"ACI Detailing Manual" WELDING: Bars shall not be welded unless authorized When authorized, Perform to ACI 301, Section 322 2. 'Welding', AWS D1A, and provide ASTM A708, grade 60 reinforcement. LACING: Conform to ACI 301, Section 3.3.2 "Placing." Placing tolerances shall conform to ACI 117. CONCRETE COVER: Conform added following cover requirements unless noted otherwise in me drawings. Concrete cast against earth ... ..... .................. 3" Concrete exposed to earth or weather.................T Barsin walls .................. ....... ................................ '/.' SPLICES: Carfwm to ACI 301, Section 3.3.21, 'Splices'. Rater fo "Typical Lap Splice and Development Length Schedule' far typical reinforwmem splices. Refer to "Column Vertical Reinforcing Splice Schedule" and "Shear Wall Reinforcing Splice Sdetlule" for iM1ose specifm elamems. Splices extracted on Individual sheets stall compy over the schedule. Mechanical connections maybe used when approved by the SER. For reinforcing within the lateral system (shear wads) and reinforcing connecting the diaphragm slab to the lateral system, mechanical splice strength Is Increased to develop 125 percent affirm specified tensile strength of the splices bar. FIELD BENDING: Conform to ACI Sol Section 3.3.2.8- "Field Bending or Straightening.- Bar sizes R3 through 45 may be field bent cold the first time. Subsequent bends and other bar sizes require preheating. Do not twist bars. Bars shall not be bent past 45 caroms. TYPICAL CONCRETE REINFORCEMENT: Unk ss noted on vie plans, concrete wells shell have the following minimum reinforcement. Contractor shell confirm minimum reinforcement of walls with SER prior to rebar fabrica- tion. TABLE of MINIMUM CONCRETE WALL REINFORCING Well Thickness HORIZONTAL Bars VERTICAL Sara Location 6" Psi @12"OC N4@1T OC center in wall a" R5@12.00 BS@12'OC center in wall to- N4@16'OC EF See @16-DC EF EF=each face 12" d4@iT OC EF Set @12-GO EF EF=each face REFERENCE STANDARDS: Conform to: i) CBC Chapter 21"Masonry." 2) ACI 530-13/ASCE 5-131TMS 402-13'Building Code Requirement for Masonry Stmdures; Herein refer- anced as MSJC. 3) ACI 630.14ffiASCE 6-lWTMS 602-13'Spectication for Masonry Structures." Herein referenced as MSJCA1 4) ACI SP-06 "ACI Detailing Manual" inducting ACI 315 "Colors and Deal of CorKuete Reinfolcermint " 5) ANSIIAWS DI.4"Structural Welding Code- Reinforcing Steel." SUBMITTALS: Conform to MSJC.1 Seddon 1.5. Submit shop drawings for review including: 11 Masonry reinforcement, size, layout, and glade in accordance with plans. 2) Material careficates for all Steel Reinforcing, Anchors, Ties and Metal Accessories cathode compliance with required strength, Wade and ASTM standards. 3) Mix Designs far each Grout Mix indicating type and proportions of Ingredients In compliance of Proportion Specification. 4) Location of expansion and rontrol joints. 5) Product Infomlation, IGO ESR Reports and Material Codifications certifying compliance for all norl approved Post -Installed Anchors. 6) Hot and/or Cold weather construction procedures. STRENGTH: The assumed compressive strength of the masonry assemblage, fm, is IGM psi based on lit Section IAB for concrete and day masonry. MATERIALS: 1) Concrete Masonry Units: Conform to ASTM C-90-14, Type -I (moisture controlled), medium weight (approx. 115 PCP) units. Provide 2000 of compressive strength to achieve masonry assembly strength indicated above under STRENGTH, 2) Mori Conform to ASTM C270, Type S, and CBC Section 2103.2 "Mother." 3) Grout Conform W ASTM C476 and CBC Sedon 2103.3 Proportion Steeofications. 4) Reinforcing Bars: Conform all Al Gentle 60 returned here and CBC Section 2103.14 unless not- ed otherwise. Lap Spaces shell be as noted on plans. Fabrication shall bra In accuNanca with MSJC 1 Seddon 2.7. 5) Joint Reinforcement. Conform W ASTM A951 and CBC Section 2103.4. 6) Anchors. Ties and Accessories: Conform to CSC Section 2103.4 and MSJC.1 Section 2.4D. T) Water Shall be dean and parable. 8) Admixtures: Admixtures shall not be used unless approved by SER. 9) Post -Installed Anchors in MA50NRY: Reference the POST- INSTALLED ANCHORS section for applicable Poet -Installed Anchors W Masonry. 10) 5econd-Hand Units: Shall not be used unless approved by SER. QUALITY ASSURANCE(fm=2000 osi): Conform to CBC Sedan 2105 "Quality Assurance'. 1) Masonry Units: A letter of camcation from the manufacturer of the units shall be provided to the SER poor to the delivery of the units to the jobsite to ensure the units comply with the compressive strength specified above and ASTM C-90A 4. 2) Modac Na morsrtesting is required 3) Grout: A letter of certfficadon from the supplier of the grout shall he provided to the SER prior W delivery of the grout to vie jobsite to ensure that the grout complies with ASTM C 476. DELIVERY STORAGE AND HANDLING: Delivery, sforage and handling of materials used for masonry construc- tion shall be per MSJC 1, Section i]. SPECIAL INSPECTION: Special Inspections shall be performed per the "TESTS AND INSPECTIONS" section of the STRUCTURAL GENERAL NOTES. ANCHORS, TIES AND CONNECTORS: Masonry anchors, ties and connedom shall be as specified on structural drawings. Consult ardi edural doormats for masonry anchor ties not Inducetl on the structural drawings. CHANGE NO. I DESCRIPTION I APPROVED I DATE EMBEDDED ITEMS: Embedded Items and Accessories shall b r in accordance With MSJC Section 6.1 and in- stalled in accordance with MSJC.1 Section 3.3D. Position and Seare in place expansion joint material, anchors and other sblrctural and nonstmcNml embedded Items before placing grout. Contractor shall refer to structural, arohitedural, mechanical, electrical, plumbing, etc. and coordinate all embedded items. MASONRY REINFORCING STEEL: Masonry reinforcing shall be as noted on plane and shall be securely placed In accordance with CBC Sections 2106, [2107, and 21081 and MSJC Section &l. Masonry shall be constraded within the tolerances Speciietl in the MSJC Unless otherwise noted on the plans, the minimum wall reinforcement shall be as allows: TABLE of MINIMUM REINFORCING Wall Thickness Vertical Bars Running Bond Stack Bond Hair. Horizontal Bars ixon4l Bars 4" N4 @ 16- OC N4 @ 32" OC W @ 32"0C 6" N5@24"OC d5@32"OC R6@40'OC 8' N5@24'OC (2)IN. @48"OC (2)g5@WOE 12' MB@32"DC (2)H5@48"OC (2)if6@48rOC Bond beams with horizontal bar or bare shall be provided at 48 inches on center and at all floor and roof lines and at the fop of the wall. Provide a bond beam With horizontal bar or bars over all openings, and extend these bars 2'- 0' pad the opening at each side. Provide a bar or bare vertically for the full height of the wall at each side of open- ings, wall ends and inessential Dowels to masonry walls shall be embedded a minimum of 1'4i" or hooked into the supporting SWcture and be of the same size and sparing as wall reinforcing. Reinfoming steel shall the as specified under "MATERIALS' Section, Provide corner bars to match the harbabr al wait relntatirg at Wall inid- sedions. Ail bars shall he lapped a minimum 46 diameters or TFY minimum unless noted on the plans. Idf1' TSL$ Reinfomed masonry lintels to be installed over all openings unless otherwise indicated an drawings. Do not splice reimordng bars within lintels and maintain 8 indl bearing minimum on each side. Jolene; odgermse nd- ed on the plans, the minimum reinforcement for lintels in T masonry shall be as follows: (1) Openings up to 42 inches wide: (2) A at bottom web of 8 inch deep lintd. (2) Openings 42 to 78 inches wide' (2) A at bottom Web d 16 inch deep lintel. (3) Openings over 78 inches wide: Reinforce per drawings CONSTRUCTION: Masonry shall be constructed in accordance with CBC Section 21M'ConsWction', and MSJC.1 Pad 3'Execulmi COLD AND HOT WEATHER CONSTRUCTION: Cold and hot weather construction shall be in accordance with MSJC.1 Section 1 AC and 1.BD. BLOCK PATTERN: Use running bond unless noted. For stack bond, follow others in MSJC Sedon 4.5. GROUTED CELLS: Fill gg cells with grout unless noted otherwise on plans. Minimum grouting spaces and cal situation shall be in accordance with MSJC Section 3.2 and MWCA Section 3.5. GROUT POUR HEIGHT' Grout Pour Height shell not exceed height specified In MSJC.1 Sedan 3.5C. • Masonry blacks shall be adequately braced to withstand fluid pressures of Grout Pouf, see temporary bracing. GROUT LIFTS: Unless otherwise noted, Grout Lifts antl pour height shall not exceed 5H 41n. Grout Lifts shall not exceed spacing of intermedlas reinforced bond beams. Grout Lifts exceeding Sit 4in shall be approved! by SER. Unless otherwise noted: Clear distance between parallel bare (and between adjacent pairs of lap spliced hers) shall be equal to the adja- cent bar diameter (for bars greater than XBJ, and not less than: 1) 1-atiYandsmagerblock, 2) Tatin"block 3) T at 12" block. Clearance loser space) between the black and the minfarctng shell be: 1) %'atfinegrout 2) >4" el course grout. Masonry Cover (Including grout and Mock wall) at masonry face exposed to each or weather Shall be: 1) 112'minlmum 2) 2" for bars pit and larger CONTROL AND EXPANSION JOINTS: Reference Drawings for typical detuils m Masonry ConVol and Expansion Joins. Location of cored and expansion joins shall be approved by SER. Unless otherwise indicated on draw - Inge, indan control and expansion loins at the following: (1) Confinuous Walls: Vertical joins at the lesser of1.5 times the wall height or 25 feet am center maximum. 12) Comers and Intersecting WallsFirst vertical joint from the corner at lesser of 1.25 times the wall height or 16 feet. 011 Atari changes in wall height and are thickness, such as adjacent to columns or pilasters. TEMPORARY BRACING: Contractor's responsible for all temporary bracing of masonry during construction. Ref- erence "CONTRACTOR RESPONSIBILITIES" Sudden for hundreds Moratorium and requirements. M00 101 West Broadway, Suite 1260 San Diego, California 92101 P'.(61912M-0501 wnvAcnengineers.com AS -BUILT PLANS PREPARED UNDER SUPERVISION OF R.C.E. NO.: S6283 EXP, 05/3Q019 ENGINEERING DIVISION APPROVALS APPROVED: CITY OF ENCINITAS - DEVELOPMENT ENCINITAS BEACH RESORT PRECISE GRADING APN: 21 SAX1-26 1&25] SUBC 5 Y NOTE: STRUCTURAL WALL DESIGN � REVIEWED &APPROVED BV a ESGIL CORP. AS PL 1&2]04 ' DRAWING NO- 14083-G S SHEET 21 OF 25 CasseM1100]%e owners Snares hc. AIRgle enxwtl LDEV-011233-2018 CHANGENO. I DESCRIPTION I APPROVED I DATE HDO Kdg�L'��0 101 West Broadway, Suite 1260 San Diego, California 92101 P: (619) 234-0501 wwiv.da-engineers.rAm 0 01400 GRADE 60 REINFORCING BAR MISCELLANEOUS BARS TOP BARS (see note#51 HOOKED BARS SIZE Ld Splice Ld Splice Ldh Vc - 4006pe1 #3 15 19 19 25 0 #4 19 25 25 33 10 #5 24 31 31 41 12 #6 29 37 37 49 15 #] 42 54 54 71 17 #8 48 62 62 81 19 #9 54 70 70 91 22 #10 61 79 79 102 25 #11 67 87 87 114 2] #14 81 N/A ins N/A 33 #E 108 N/A 140 1 N/A 43 2' CLR 11014 TANALL TYP PER PLAN • - z NOTE ? 7m FIN GRADE,, THIS DETAIL APPLIES TO WALLS 12, 13. 14 AND 15 FOUND IN THE PRECISE GRADING PLANS. z _ �. PER PI -AN y; _J FILTER FABRIC -r; RETAINING WALL / FOOTING SCHEDULE WALL HORIZ RUNE CONCRETE WALLS VERT CONTROL JOINT ED PER SCH PER VERT REINF WALLIFOOTING SIZES IWALL REINFORCEMENT FOOTING REINFORCEMENT PER14/SHEET22 PERSCHED H TOE is HEEL tf D VERTICAL HORIZONTAL TOPTRANSV TOPLONGIT BOT LONGIT BOT TRANSV WATERPROOFING 2'-0" 0'-6' 8' 1'-0" 12' WA #5®12"OC #501 YOC #5018"OC #5012"0C #5012.00 #5018.00 DOWELBW/STDHOOK BYOTHERS TO MATCH VERT pEINF PROVIDE FREE DRAINING MATERIAL PER 4'-0' V-0' 8' 1'-fi' 12' N/A #F 01200C IS 01 WOC #501WOC 9012VC #5012'OC #50IFOC '^ 0 GEOTECH REPORT tk4'KEY 6'-P' 1'-6" 8' 2'-6. 18' WA #501200C #5015'OC il5®18°OC #5®12'9C #5012.00 #5018"DC WE+ z a o P ti, ''(� GONT FR36RAIN PER CIVIL q;°' 8'-0' 2'-0° B 4'-0' 18' WA #6012'0L #5418"OL "18'OL 111 #6012'l7C #5018'OC ¢ag FTG TOP TRANSV REINF FIN GRADE ap 0 - IW/LOOP PER SCHED PER ARCW 5" _ FTG TOP LONGIF RETAINING WALL / FOOTING SCHEDULE CIVIL a = I, FREI F PER SCHED CMU WALLS WALL/FOOTING SIZES WALL REINFORCEMENT FOOTING REINFORCEMENT z 4° 0 TOE is HEEL tf D VERTICAL HORIZONTAL TOP TRANSV TOP LONGIT BOT LONGIT EDT TRANSV • -_ 2'-0" 0'-6" 8" 1'-O" 12" N/A #5 ® 24"OC (2)#5 0 16'OC #.5 0 18.00 J5 0 12.00 /5 0 12.00 #5 0 18"OC _- - g ^ _— " 0 3' - PTO SOL LONG IT 4'-0' V-O" 8" 1'-6" 12" N/A #5 0 24"OC (2)#5 0 16"00 #5 0 WOO #5 0 12"OC #5 0 12"OC #5 0 18"OC o CLR REINF PER SCHED is 6'-0" V-6" 8" 2'-6" 12" N/A #5 0 16"OC (2)#5 0 16'OC 15 0 WES 15 0 12"OC #5 a 12'OC #5 a 18"OC TOE HEEL FTG BOTTRANSV REINF PERSCHED 8'-0" Z'-0" 8" 4'-0" 12" N/A #6 ® 8"OC (2)#5 0 16"OC #5 018"OC #5 012"OC #5 ® 12"OC #5 018"OC CANTILEVERED CAST IN PLACE SITE RETAINING WALL AND SCHEDULE (NO SLOPE TO BACKFILL) SCALE: 3/4'= VHS' 102304) 3/4" CHAMFER STD HOOK AT WALLS NOT IN CONTACT W/ SOIL NP ° V ° •" " CORNER REINF CORNER REINF z Z z TO MATCH TO MATCH n v1 w HORIZ REINF CROSS WALL e R". HORIZ gEINF CROSS I I° WALL AT CORNERS NOTES: 1, SPLICE LENGTHS PER LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE. 2. WALL REINFORCING PER PLAN OR ELEVATIONS, SECTIONS AND DETAILS. 3, AT FOOTINGS AND 5TEMWALLS, CORNER REINFORCING TO MATCH FOOTING AND STEMWALL HORIZONTAL REINFORCING. PLAN - TYPICAL CORNER REINFORCING 0AT CONCRETE WALLS SCALE: 3/4'=1'03 (03403-0OUS LE MAT) EXT FACE III���CLR COVER PER IWAL_ SECTIONS,TYP WALL REINF EF WHERE OCCURS PLAN FIN GRADE PER ARCH/ SF CIVIL z NOTES: 1 (- 1. ALLTABULATED VALUES ARE IN INCHES. 11 .'. I I, PI - °I I" CONC RETAINING WALL PER PLAN & WALL SECTIONS VERT REINF PER PLAN _ &WALL SECTIONS, TYP III I HORIZ WALL HEINE PER PLAN, WALL SECTIONS & PLAN BELOW, TYP 2- VALUES FOR UNCOATED REINFORCING AND NORMAL WEIGHT CONCRETE WITH CLEAR SPACING> db, CLEAR COVER>& AND MINIMUM STIRRUPS OR TIES THROUGHOUT Ld OR CLEAR SPACING>2db AND CONTROL JOINT �` SECTION CLEAR COVER> db. 3. DEVELOP ALL REINFORCING IN STRUCTURAL SLABS WITH MINIMUM DEVELOPMENT LENGTH Ld. 4. Ldh = DEVELOPMENT LENGTH OF BAR WITH STANDARD HOOK. W HEN VERT REINF IS NOTES: DIRECTLY BEHIND CONTROL 5. TOP BAR= HORIZONTAL BAR WITH MORETHAN I2'OFFRESH CONCRETE BELOWORAS NOTEDON CQ. -.I'- JOINT, ADJUST AS SHOWN DOCUMENTS AS' TOP BAR'. 1. VERTICAL COMROLJOINIS 'T TO BE LOCATED PER^� h 5. LAP SPLICE OF DIFFERENT SIZED BARS TO BE THE LARGER OF Ld OF THE LARGER BAR OR SPLICE LENGTH ARCHITECTURAL. MAXIMUM OF THE SMALLER BAR. SPACING EQUAL TO 10' 'OC OR HEIGHT OF WALL, 7. LAP SPLICE OF#14 AND#18 BARS IS NOT PERMITTED . LAPSPLICEOFSMALLERTO#14AND#1BBABSIS WHICHEVER IS LESS NOTPERM17ED. 3/" a "• ALTERNATE HORIZ REINF TO 2, JOINT BOTH SI DES FOR ° I BE DISCONTINUOUS AT EA 8, LAP SPLICE OF DIFFERENT GRADES OF REINFORCING TO BE TH E LARG ER OF IA OF THE HIGHER GRADE WALL THICKER THAN 8"OR CONTROLJOINT, BAR OR SPLICE LENGTH OF TH E LOWER GRADE BAR. EXPOSED ON BOTH SIDES. PLAN EF WHERE OCCURS TYPICAL LAP SPLICE AND VERTICAL CONTROL JOINT AT DEVELOPMENT LENGTH SCHEDULE �� CONCRETE RETAINING WALLS I9 13 SCALE: 3/4"=1'-0' (01400) SCALE: 111T=V-0- l023101 Fccof F JAMFs DE51ON BC AS -BUILT ML pHAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS- DEVELOPMENT SERVICES DEPARTMENT TJH JW 8283 �^ 5 19 64 B t�$ /2 �/ PLANS PREPARED UNDER SUPERVISION OF _ DATE : ' RC.E.N2y0. S�623 JU WEI EXR 06taNO19 RECO N APPROVED'. �(L/J��� 1 STEVETV WAK EDWARD J. VER 8• DATE 1 DATE ENCINITAS BEACH RESORT PRECISEGRADING APN: 216(141-26 PLANNING CASE NO: TPM-89414 18-257SUBC STIN WEI UATE --_4-1-21"/f6,�k' SENIOR ENGINEER REVIEWER INSPECTOR DRAWING NO. 14083-G SHEET 22 OF 25 ®cogpmmx�e o'Amab CdF9vwlrc.an#IN nmva LDEV-011233-2018 REINFORCING SIZE GRADE60 #a 24 #5 30 #6 36 #Z 42 #B 48 NOTES: 1. DEVELOPMENT AND LAP SPLICE LENGTHS INDICATED SHALL BE USED UNLESS SPECIFICALLY NOTED ON DRAWINGS. 2 REINFORCING MAYBE CONSIDERED TO BE SPLICED WHEN PLACED IN ADJACENT CLJOINT VERT CONTROLJOINT OMIT MORTAR. CAULK PER ARCH TERMINATE HDRIZ REINF 2'FROM CONTROL JOINTS, EXCEPT AT FILE &ROOF BOND BEAMS - eieeeeene�eiea �11 ��e�eiee�'e�eieee� PROVIDE 16" SMOOTH DOWEL VERT REINF PER PLAN (SAME SIZE AS HORTZ REINH ACROSS JOINT, PREVENT BOND BTWN DOWEL & GROUT W/ GREASE OR PLASTIC SLEEVE. CAP ALL DOWELS TO ALLOW 1"OF MOVEMENT. PROVIDE CLOSED END BLOCKS AT CONTROL JOI MS, TYP AT CORNERS AT INTERSECTIONS RETAINING WALL / FOOTING SCHEDULE CONIC CMU FOOTING SIZES WALL REINFORCEMENT FOOTING REINFORCEMENT H VERTICAL HORIZONTAL y HOT WCMU tf TOE HEEL D W TOP TRANSV TOP LONGIT BOT LONGIT BOT TRANSV DOING CMU CONC GMU a 4'-0" 8" N/A 1'-6" 1'-0"2'-6"N/A N/A #5 0 12°OC N/A #5 0 12'OC N/A #5 0 18"OC #5 0 78"OC #5 0 18"OC #5 0 18"OC 6'-0" 8" N/A 2'-0' i-6" 3'-0- 0'-6" 0'-6" #6 0 1VOC N/A #5 0 12"OC N/A #5 0 12"OC #5 0 12"OC #5 0 12"OC #5 9 12"0C T-O" d4'-On 12" N/A 2'-0- 2'-6° 4'-6" 1'-0- 1'-C" #8 0 1VOC N/A #5 0 12"0C EF N/A #5 0 12"OC #5 0 12"OC #5 0 12"OC #5 0 12"0C 10'-0" 12" N/A 2'-0' S-6" 5'-6" 1'-6" V-6" #8 0 12°OC N/A #5 0 12"0C EF N/A #5 0 12"OC #5 0 12"OC #5 0 12"OC #5 0 12"OC 12'-0" 12" N/A 2'-6" 4'-6" 6'-6" 7-0" 1'-6" #8 0 8"OC N/A #5 0 1200C OF N/A #5 0 10"OC #5 0 10"OC #5 0 10"OC #5 0 10"OC RETAINING WALL / FOOTING SCHEDULE CONIC CMU FOOTING SIZES WALL REINFORCEMENT FOOTING REINFORCEMENT H VERT HDRIZ HC WC HCMU WCMU 11 TOE HEEL D W TOPTRANSV TOP LONGIT BOTTRANSV BOT LONGIT CONIC CMU CONIC CMU 4'-0" NIA NI 4'-0" W 1'-w 1'-V 2'-6 WA WA N/A #5424CC N/A (2)K 016"OC #5018'OC #5010"OC #5@18OC #5018'0C 6'-0" N/A WA 6'-0' 1" 2'-D" 1'-6" 3'-0' 01 B" 0'-6- NIA #6a 16"0C N/A (2W50 WOO #501210C #5012"OC #5012'CC #5012'OC 8'-0" NIA N/A a-0' 12" 2'-0" 2'-6' 4'-6- 1'-0' 1'-0' N/A #Ba 16'OC N/A (21#5016'OC 05012'OC #5012.00 #5012OC #5012.00 101fY 2'-0, 12' 8'-0' 12" 2'-OF 3'-6 5'-6" 1'-6' 1'-6' #8012'OC #B016"OC #5@12mOCEF GM WOO #501TOC #5012'OC #5012"CC #50ITOC 12'D' 4'-0" 12' a' 0' 12" 2'-F 4`-W 6'-6' 2'-0" 1'-8' #808CC #80 ITOC M01T'OC EF (21#5016'OC #5010"DO #501010C #501010C #5010'OC CMU WALL VERT DOWELS W/ST) HOOK TOM H VERT REINE- #6 @ 15'0C o CONC WALL HORIZ REINF x 1'-0' a GRADE VARIES PER CIVIL CMU WALL HDRIZ REINF PER SCHED CONC WALL VERT REINF PER SCHED PROVIDE FREE DRAINING MATERIAL PER GEOTECH REPORT WATERPROOFING BY OTHERS CONT FTG DRAIN PER CIVIL FTG TOP TRANI HURT (WI HOOK) PER PORED FTG TOP LONGIT REINF PER SOILED -3-CLR `FTG BOT LONGIT TYP REINF PER SCROD + I � I I HEEL TOE FTG ROT TRANISV REINF NOTE: PER SCHED RETAINING WALL TO BE BACKHLLED PRIOR TO START OF WOOD FRAMING. 9 CANTILEVERED CAST IN SCALE: 3/4'=1'-0' (02304) TO 1SH MIN, UNO PER PLAN TO MATCH FTG REINF V 6 TIFTG PERPLAN AS POSSIBLE III PER PLAN WALLVERT REINF, TYP fez V r x a 2 T1FTG LL PER PLAN GROUTED CELLS AND IF THE BARS ARE SPACED NO FARTHER APARTTHAN 1#i THE NOTES: .III-1I 1.. 1 =11 I� REQUIRED LENGTH INDICATED AND NEVER FURTHER APART THAN T 1. LAP LENGTHS PER REINFORCING LAP SPLICE AND DEVELOPMENT LENGTH 1.5 H FTG FEINT 3. ALLTABULATEDVALUESAREININCHES. SCHEDULE FOR CMU. MIN, UNO TO MATCH FTG PER PLAN TYP, NOTE: 2. WALL REINFORCING PER PLANS, ELEVATIONS, SECTIONS AND DETAILS. PER PLAN THICKNESS CONTROL JOINT LOCATIONS SHALL BE THE LESSER OF 1.5 TIMES WALL HEIGTH OR 25PL. JOINTS SHALL TYPICAL LAP SPLICE AND ALSO BE PLACED 4 ABRUPT CHANGES IN WALL HEIGHT AND THICKNESS CONTRACTORSHALL 3. CORNER REINFORCING ATFOOTINGAND STEMWALLSTOMATCH FOOTING COORDINATE LOCATION OFJOINTWITH ARCHITECT AND STRUCTURAL ENGINEER. AND STEMWALL HORIZONTAL REINFORCING. DEVELOPMENT LENGTH PLAN - TYPICAL CORNER REINFORCING SCHEDULE FOR STRUCTURAL MASONRY PLAN - CMU CONTROL JOINT AT CMU WALLS �1 TYPICAL STEPPED FOOTING 11 12 13 SCALE. 3/4' =1'-0' (01402) SCALE: 1" = 10" SCALE: 1' =1'-0" 104002) SCALE: 31W = V U (039OR NOTE: THIS DETAIL APPLIES TO WALLS 3, ], 8. ➢, 10, AND 11 FOUND IN THE PRECISE GRADING PLANS. lne 46° 210 MIN °❑ D D D) 1eo° 4s° D=6d FOR#3T#8 10 D=Bd FOR#9,#1081#11 D -iDd FDR Rtd&#1R ¢oz09 12d � 2 D 160° -- 19s°. 1- ` I D d d' ❑ D D STIRRUP STIRRUP OR TIE D=4d FOR#3,#4&#5 D = 6d FOR #6, #] & #B 90° 135° 90° D160I Ed OR D D T ❑ I III""ITT-I3'MIN � in 0 min BEAM OR COLUMN CROSSTIES NOTE: BEAM STIRRUPS AND COLUMN TIES d=BARDIAMFTER, D=BENODIAMETER TIES AND CROSSTIES FOR SHEAR WALL BOUNDARY ELEMENTS SHALL BE DETAILED AS COLUMN TIES/CROSSTIES. STANDARD HOOKS AND BENDS - 15 BEAM STIRRUPS AND COLUMN TIES I� SCALE 3/4"=1-0" 103400) NOTE. CHANGE NO, DESCRIPTION APPROVED DATE JA,yfS AS -BUILT B RA N DESIGNED DBY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS-DEVELOPMENTSERVICES DEPARTMENT ME ITH JW IL 4-1-21 tiD PLANS PREPARED UNDER SUPERVISION OF APPROVED: ENCINITAS REACH RESORT f�t'w�101 West Broadway, Rn aR lR 9®DATE:z Suite 1260 ♦ -Tip. 6 30 19 y USTIN WEI DATE R.C.E. NO.. EECOMND: EDWARD J. ARE PRECISE GRADING San DIBJ0, California 92101 'i` �Q FjF 4-1-21 JUSTIN WEI EXP.. 06f30/2019 p C APN. 216-041-26 P:(619)234-ND1 a .dei-engieeem.con REVIEWER INSPECTOR SENIORENGINEER GATE DATE PLANNING CASE NO. TPMe9-014 18-257 SUED ®Cpp- — I O'— Ifm,wvm Fo.NIP—PeevwG REVIEWED & APPROVED DRAWING NO. iuiFk3e] SHEET 23 OF LDEV-011233-2018 3 S STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMPAMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS, THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED 'VIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN -QUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN /ED HYDROCARBON FILTER AND DISCHARGED INTO THE NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A REQUIRED FOR THIS STRUCTURE. GRAVEL BAGS PERIMETER DIRECTION OF FLOW 2 GRAVEL BAGS HIGH (OMIT ONE (1) BAG ON TOP ROW FOR INFLOW) pML INLET PROTECTION DETAIL (SE-10) NOT TO SCALE LEVEL CONTOUR SPACING SLOPE ELEVATION S < 4:1 20' 4.1 < S < 2:1 15' S < 2:1 10, 1" x 1" STAKE NOTE: 1. STRAW ROLL INSTALLATION REQUIRES THE PLACEMENT AND SECURE STAKING OF THE ROLL IN A TRENCH, 3"-5" DEEP, DUG ON A CONTOUR. RUNOFF MUST NOT BE ALLOWED TO RUN UNDER OR AROUND ROLL. FIBER ROLL BARRIER DETAIL (SE-5) NOT TO SCALE NOTE THIS PLAN DEPICTS FINAL GRADED CONDITION; HOWEVER, INTERIM EROSION CONTROL MEASURES NOT SHOWN HEREON MAY/WILL BE REQUIRED DURING THE VARIOUS CONSTRUCTION PHASES AT DISCRETION OF ENGINEERING INSPECTOR AND PROJECTS QSP. COVERAGE UNDER STATE CONSTRUCTION PERMIT PER WORD: 9 37C381021 QSD: WILLIAM MCKNIGHT, CERTIFICATION NO. 00973 QSP INSPECTOR: HUNTER MAUL, CESSWI NO. 26114 24-HOUR CONTACT NUMBER 760-835-7755 RESPONSIBLE PARTY: ENCINITAS BEACH HOTEL VENTURE, LLC. CURB & GUTT OVERFLOW WATER SURFACE GRAVEL i HARDWARE WIRE MESH CONC. BLOCK LAID LENGTH'MSE- INLET PROFILE VIEW PLAN VIEW 3S HIGH LWAY 1 HIGH STORM DRAIN INLET PROTECTION DETAIL (SE-10) NOT TO SCALE. 1. EXCAVATE A 4 BY 4 IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE PROPOSED LINE OF POSTS. 4 IN (10 CM) 2. SET POSTS OF PREFABRICATED 3, BACKFILL AND COMPACT SILT FENCING AND EXTEND SILT THE EXCAVATED SOIL. FENCING INTO THE TRENCH. NOTES 1SILT FENCE TO BE LOCATED WITHIN 5 FEET OF TOP OR TOE OF SLOPE WHERE APPLICABLE 2. SILT FENCE WILL TERMINATE 1 FOOT ON EITHER SIDE OF RIP RAP ENERGY DISSIPATORS. SILT FENCE DETAIL (SE-1I NOT TO SCALE . ... - s , IrLilw1*11.110 W -'X01 13 AI rai a PLANS PREPARED UNDER SUPER "SIO, OF • / r DIED: APPROVED: HORIZONTAL: N/A DA 17 TE vf ' I ' P.? E:7iYB.Fi9 tNR ]:igQC® 0.MARK L. HENNING 0 ,. I �, ,. GRAVEL -FILLED BAG DIMENSIONS 18" X 12" X 3" WEIGHING N 33LBS. USE 1/2" - 1" GRAVEL. DRAINAGE CONDITION (TYP.) GRAVEL BAG BERM DETAIL (SE-6) NO SCALE DIRECTION OF FLOW 1 BAG MIN. GRAVEL BAGS (TYP) O TYPI AL TYPICAL ES CT1ON ELEVATION GRAVEL BAG PLACEMENT DETAIL (SE-6) NOT TO SCALE s NOTES: 1. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBUC RIGHT-OF-WAYS. THIS MAY REWIRE TOP DRESSING, REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 2. WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY, 3. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON A AREA STABILIZED WITH CRUSHED..: STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. STABILIZED CONSTRUCTION ENTRANCE DETAIL (TC-1� NOT TO SCALE OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. :ONTROL NOTES & DETAILS FOR: ENCINITAS BEACH RESORT 14U83-G PRECISE GRADING APN: 216-041-26 PLANNING CASE NO: TPM-89-014 LDEV-011233-2018 LDEV-011233-2018