2018-14094 G (Plans) (2)m N 0 rn 0 d- CV 0 N a� v N c 0 c 0 v 3 v I 0 IL 0 1 a v+ c v 0 0 0 0 CN 0 0 1 N 0 Q a 0 c 0 V) v 0 i v c ;n a) Z) -90 2 GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED "GEOTECHNICAL EVALUATION SAN DIEGO BOTANIC GARDEN" PREPARED BY NINYO AND MOORE DATED MARCH 15, 2016, AND UPDATE DATED NOVEMBER 14, 2018, PROJECT#108685001 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. S. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT 14094-G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT, DIRECT OR TEMPORARILY HALT GROUND -DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIVITIES ARE ALLOWED TO RESUME. Ica JNDERGROUND SERVICE ALERT CALL: TOLL FREE (800)422-4133 TWO WORKING DAYS BEFORE YOU DIG "CAUTION": REMEMBER THAT THE USA CENTER NOTIFIES ONLY THOSE UTILITIES BELONGING TO THE CENTER. THERE COULD BE OTHER UTILITIES PRESENT AT THE WORK SITE. THE CENTER WILL INFORM YOU OF WHOM THEY WILL NOTIFY. DESCRIPTION SNT130 01 -§ a 311 SAXONY LANE, ENCINITAS, CALIFORNIA GENERAL NOTES CONTINUED 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED ARCHAEOLOGIST AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THE CORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097.98. IF SUCH A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND/OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT INSITU(IN PLACE"), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. TOPOGRAPHY SOURCE THE EXISTING TOPOGRAPHY AS SHOWN ON THESE PLANS FOR THE MAIN PROJECT SITE WAS DETERMINED BY FIELD SURVEY CONDUCTED BY. COUNTY OF SAN DIEGO (11-03-15) THE EXISTING TOPOGRAPHY AS SHOWN ON THESE PLANS FOR OFFSITE SEWER AND WATER IMPROVEMENTS WAS PROVIDED USING AVAILABLE SAN DIEGO COUNTY GIS CONTOUR FILES BASIS OF BEARING HORIZONTAL CONTROL IS BASED ON THE CALIFORNIA COORDINATE SYSTEM, ZONE 6, NAD83 (NSRS2007) DATUM EPOCH 2O11.00. THE DATUM WAS ACCESSED USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) "CLBD", AS THE BASE STATION. RTN GPS METHODS WERE USED TO ESTABLISH ADDITIONAL CONTROL POINTS. ADDITIONAL CONTROL POINTS WERE ESTABLISHED DURING DATA COLLECTION. VERTICAL BENCHMARK ELEVATIONS ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) WHICH WAS ACCESSED USING THE CORS STATION AND THE NGS GEOID MODEL 'GEOID09' NAwsa PT# NORTHING EASTING ELEV STATION 101 1964992.1067 6245073.5110 226.93 FND LD RCE22606 102 1964982.2401 6245752.4478 287.14 FND 3/4"IP LS415 103 1964341.4305 6245064.0612 209.88 FND 3/4"IP RCE27 104 1964334.0299 6245719.6377 267.27 FND 2"IP RCE2957 301 1964667.3982 6245218.2860 232.31 TCP 1 302 1964397.4160 6245146.3499 220.61 TCP 2 303 1964520.5858 6245237.1859 229.75 TCP 3 304 1964345.3070 6245823.4120 279.73 TCP 4 305 1964489.1570 6245837.0440 287.76 TCP 5 306 1964446.9210 6246034.6310 259.41 TCP 6 SHEET INDEX: SEE SEPARATE COUNTY OF SAN DIEGO 01- TITLE SHEET 02- NOTES AND KEY MAP APPROVED BUILDING PERMIT AND 03- GRADING PLAN LANDSCAPE & IRRIGATION PERMIT FOR 04- SITE SECTIONS AND BASIN DETAILS ADDITIONAL PROJECT INFORMATION 05- PRECISE GRADING PLAN _ 06- PRECISE GRADING PLAN 07- PAVING DETAILS 08- OVERALL WATER PLAN 09- WATER PLAN AND PROFILE 10- WATER PLAN AND PROFILE 11- EROSION CONTROL NOTES 12- EROSION CONTROL PLAN 13- KEYSTONE WALL NOTES 14- KEYSTONE WALL KEY MAP 15- KEYSTONE WALL SECTION & DETAILS 16- KEYSTONE WALL 1 & 2 PROFILES VICINITY MAP: BENCHMARK AS -BUILT APPROVALS 1 FIELD SURVEY CONDUCTED BY COUNTY OF //3 2 ► PUBLIC WORD SAN DIEGO USING THE CONTINUOUSLY - OPERATING REFERENCE STATION (CORS) JOH P INC , P.E. DATE PLANNING AND THE NGS GEOID MODEL'GEOID09'. DATUM:NAVD88 StPNP✓NOWGLIy 3/9/21 REVIEWER CITY ENGINEER DATE INSPECTOR U) z EARTH WORK DATA STEEPEST EXISTING NATURAL SLOPE ON -SITE = 13 H 1 V MAXIMUM VERTICAL DEPTH OF CUT = 2 MAXIMUM VERTICAL DEPTH OF FILL = 4 CUT = 170 C.Y. FILL = 1,100 C.Y. IMPORT = 900 C.Y. REMEDIAL = 1,350 C.Y. (5' REMOVAL AND RECOMPACTION UNDER AND 5' OUTSIDE OF BUILDING AREAS) DISTURBED AREA = 39,900 S.F. IMPERVIOUS AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 0 SQFT IMPERVIOUS AREA AFTER CONSTRUCTION: 23,200 SQFT INCREASE IN IMPERVIOUS AREA: 23,200 SQFT IMPERVIOUS AREA REPLACED: 0 SQFT OWNER'S CERTIFICATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY. AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLAN-0 _11 - S ZNTRIVATE PROPERTY OR PUBLIC EAS MENT . SIGNATU . DATE: A ALBRIGHT DIRECTOR OF PARKS & RECREATION FOR THE COUNTY OF SAN DIEGO SOIL ENGINEER'S CERTIFICATE I, RONALD S. HALBERT, P.E. A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON MARCH 15, 2016 AND FOR AN UPDATE ON NOVEMBER 14. 2018. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATE THE GRADING PLANS AND SPECIFICATIONS. SIGNED: �� RCE NO.: 042204 ESSIO Qt69��V EXP. DATE: 3-31-2020cr Nv- p�i22 JOB #: 108685001 c� >Mxp. NINYO & MOORE ON�� 5710 RUFFIN ROAD, SAN DIEGO, CA 92123 � (858)-576-1000 STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. (:aa H INCfESS$,�' ems,, OQEUL Pq SIGNATURE: 0I S111J E, .E. C72279 DATE: DELANE ENGINEERING `�'' No. C72279 ^' 4909 MURPHY CANYON ROAD, SUITE 330 E+w• 8/30/2o 66 RCE EXPIRES6/30/20 �f'lf OF ck\.%' 0+� DELANE pon 4909 MURPHY CANYON ROAD, SUITE 330 SAN DIEGO, CA 92123 PHONE: 619.787.5566 OWNER COUNTY OF SAN DIEGO 5500 OVERLAND AVENUE, SUITE 410, SAN DIEGO, CA 92123 (858) 694-3030 SITE ADDRESS 311 & 315 SAXONY LANE, ENCINITAS, CA 92024 APN: 256-340-31-00 LEGAL DESCRIPTION PORTION OF S HALF OF N HALF OF SE QTR OF SW QTR OF SECTION 10, TOWNSHIP 13 SOUTH, RANGE 4 WEST, SAN BERNARDINO MERIDIAN, PER US GOVT SURVEY APPROVED APRIL 19, 1881 AS BUILTS THE CONTRACTOR SHALL FURNISH TO THE ENGINEER OF WORK, AS -BUILT PLANS FOR ALL NEW IMPROVEMENTS AND GRADING SHOWN ON THESE PLANS FOR SUBMITTAL TO THE CITY ENGINEER FOR APPROVAL IN ACCORDANCE WITH ENCINITAS MUNICIPAL CODE WORK TO BE DONE: THE WORK TO BE DONE CONSISTS OF THE ITEMS INDICATED UNDER THE "LEGEND" SHOWN BELOW, AND IS TO BE DONE IN ACCORDANCE WITH THESE PLANS. 1. WATER AGENCIES STANDARDS SPECIFICATIONS AND DRAWINGS FOR WATER, RECYCLED WATER AND SEWER FACILITIES, LATEST EDITION. 2.2015 SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. 3. 2012 STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION ("GREENBOOK") AND 2012 REGIONAL SUPPLEMENT AMENDMENTS (TO THE GREENBOOK). 4. CALIFORNIA DEPARTMENT OF TRANSPORTATION U.S. CUSTOMARY STANDARD SPECIFICATIONS AND PLANS, 2015 EDITION LEGEND: DWG. NO. RIGHT OF WAY ............................................... PROJECT BOUNDARY ............................................... EASEMENT .................................................... PROPERTY LINE .................................................. PROPOSED A.C. PAVING EX A.C. PAVING ................................................ CONCRETE SIDEWALK/PAVING ........ S.D.R.S.D. NO. G-7............. GRADE BREAK .................................................... 6" CURB & GUTTER TYPE G......... S.D.R.S.D. NO. G-2............. EDGE OF CONCRETE PAVING ........................................ 6" CURB.........................S.D.R.S.D. NO. G-1............. WATER MAIN (DOMESTIC) ........ W.A.S WP-01, WP-02................ WATER SERVICE** (SIZE PER PLAN) ................................ (SUBMETERS TO BE INSTALLED PER BUILDING PLANS) FIRE LATERAL....................4" PVC C900 W.A.S WF-05........ FIRE HYDRANT ASSEMBLY ........... W.A.S. WF-01 & WF-04........... GATE VALVE ...................... W.A.S. WV-02, WV-03............ AIR VACUUM VALVE................W.A.S. WA-07, WC-17............ BLOW -OFF TYPE C................... W.A.S. WB-06, WC-17............ CONCRETE THRUST BLOCK ........... W.A.S. WT-01................... SEWER MAIN - PUBLIC (SDR 35).... S.D.R.S.D. NO. SP-2............ SYMBOL W -, SEWER MAIN - PRIVATE (SDR 35)... S.D.R.S.D. NO. SP-2............ S 5' SEWER MANHOLE ................S.D.R.S.D. NOS. S-2, M-4....... PVT. SEWER CLEANOUT.............S.D.R.S.D. NO. S-3............. 4" SEWER LATERAL ................S.D.R.S.D. NOS. S-13........... --� EX. SEWER END CAP .............................................. PVT. STORM DRAIN PIPE ........... S.D.R.S.D. NOS. D-60, D-61..... - - - - EX. STORM DRAIN PIPE ............ S.D.R.S.D. NOS. D-60, D-61..... -- PVT. CURB INLET, TYPE B......... S.D.R.S.D. NO. D-2............. Fol PVT. CURB INLET, TYPE A-1....... S.D.R.S.D. NO. D-1............. PVT. STORM DRAIN CLEANOUT(TYPE A) ... S.D.R.S.D. NO. D-9......... -� PVT. STORM DRAIN CATCH BASIN ..................................=-- STREET LIGHT PER SEPARATE PERMIT ...............................-� RETAINING WALL ................................................. BROW DITCH ............. .......S.D.R.S.D. NO. D-75......... ... -> => ROCK MULCH SWALE............................................... BMP PROJECT STATUS ppp-NN1? PRIORITY STORMWATER TREATMENT FACILITIES TO BE MAINTAINED BY CWArq 01rSAI✓ 8*40 rn±R) IN ACCORDANCE WITH "MAINTENANCE AGREEMENT FOR PRIVATE STORMWATER TREATMENT AND STORMWATER POLLUTION CONTROL FACILITIES" RECORDED ON ALC-j 25T_ Z7 Z�fx� AS DOC. #: PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT SDWD W17-070 SIGV DATE �N B A-3 DATE SIGN DATE l l 1 GN DATE SIGN DATE BY: INT. DATE PLANS PREPARED UNDER SUPERVISION OF NA DATE: g 1511 N-A r-r R.C.E. NO.: C72279 J4o 3/61 KK 3/Q J HA PRINC P.E. EXP.:6130/20 ENGINEERIN_ DIVISION APPROVALS RECOMMENDED: �4APP OVED: JES ENS 4WIM ARD MJ.e7M i M E R /; `� CITY_NGIN DATE DAT CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: DRAWING NO. 14094-G SHEET 1 OF 1 SPECIAL NOTES: 1. THE FOLLOWING NOTES ARE PROVIDED TO GIVE DIRECTIONS TO THE CONTRACTOR BY THE ENGINEER OF WORK. 2• THE ENGINEER OF WORK SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, NOR SHALL THE ENGINEER BE REQUIRED TO SUPERVISE CONDUCT OF THE WORK OF THE CONSTRUCTION PROCEDURES AND SAFETY PROCEDURES FOLLOWED BY THE CONTRACTOR OR SUBCONTRACTORS OR THEIR RESPECTIVE EMPLOYEES OR BY ANOTHER PERSON AT THE JOB SITE OTHER THAN THAT OF THE ENGINEER'S EMPLOYEES. 3. THE LOCATIONS OF ANY UNDERGROUND STRUCTURES AS SHOWN ON THESE PLANS HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR THE BENEFIT OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONARY MEASURES TO PROTECT ALL UNDERGROUND OR OVERHEAD STRUCTURES WHETHER SHOWN OR NOT ON THESE DRAWINGS 4. FOR ELECTRONIC FILES OF THE HORIZONTAL CONTROL OR ONSITE IMPROVEMENTS, CONTRACTOR SHALL CONTACT THE ENGINEER OF WORK AT (619) 787-5566. 5. THE CONTRACTOR SHALL VERIFY THE LOCATION OF AND PROTECT ALL EXISTING IMPROVEMENTS BEFORE AND DURING CONSTRUCTION. 6. CONTRACTOR SHALL MAKE EXPLORATION EXCAVATIONS AND LOCATE EXISTING UNDERGROUND UTILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF LOCATION OF EXISTING UTILITIES. 7. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE 'PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 8. IF ANY EXISTING HARDSCAPE OR LANDSCAPE, INCLUDING STRIPING, INDICATED ON THE APPROVED PLANS IS DAMAGED OR REMOVED DURING DEMOLITION OR CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT IT SHALL BE REPAIRED OR REPLACED IN KIND AND EQUIVALENT SIZE PER THE APPROVED PLANS. RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DIVISION AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING) OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - CSD/ESD - (760)-633-2770 LWD 760-153-0155 B. GAS & ELECTRIC - SDGE - (760)-438-6200 C. WATER - SAN DIEGUITO WATER DISTRICT-1-800-227-2600 D. TELEPHONE - SBC BELL - (760)-489-3411 E. CABLE TV - COX COMMUNICATIONS-(760)-806-9809 X-2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)-633-2770. M 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: 00 (760)633-2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO cv REJECTION AND REMOVAL. d- EROSION CONTROL 0 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOHN SCHMITZ AT (760) 315-3055, cn 24 HOURS A DAY. r- 0 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL r TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE 0 RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. c c°� 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 0 L < 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. v 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO NI PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 1 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE c� INCORPORATED HEREON. 04 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF r SLOPE AT THE CONCLUSION OF EACH WORK DAY. E 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. v 0 0 r Q r - N CHANGE NO. DESCRIPTION APPROVED DATE 0 0 N 2 AS -BUILT SIR N 319121 0 n N STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SF+ALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195, FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/BMP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE, THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. BENCHMARK AS -BUILT APPROVALS G " : o AC ASPHALTIC CONCRETE PCC PORTLAND CEMENT CONCRETE ACC ACCESSIBLE PIV POST INDICATOR VALVE BFP BACKFLOW PREVENTOR POC POINT OF CONNECTION BW BOTTOM OF WALL PB PULL BOX CL CENTERLINE RIM RIM OF STRUCTURE COVER CO CLEANOUT RW RECYCLED WATER CONC CONCRETE R/W RIGHT OF WAY CYD CUBIC YARDS S SEWER EX EXISTING SCO SEWER CLEANOUT EOP EDGE OF PAVEMENT SD STORM DRAIN FDC FIRE DEPARTMENT CONNECTION SFM SEWER FORCE MAIN FFE FINISH FLOOR ELEVATION SMH SEWER MANHOLE FG FINISH GRADE SWPPP STORM WATER POLLUTION FH FIRE HYDRANT PREVENTION PLAN FL FLOWUNE TB TOP OF BOX FS FIRE SERVICE TB THRUST BLOCK FS FINISH SURFACE TC TOP OF CURB GB GRADE BREAK TD TRENCH DRAIN G&O GRIND AND OVERLAY TF TOP OF FOOTING HH HANDHOLE TG TOP OF GRATE IE INVERT ELEVATION TP TOP OF PIPE IRR IRRIGATION TW TOP OF WALL LF LINEAR FEET TYP TYPICAL LG LIP OF GUTTER W WATER LOW LIMIT OF WORK WM WATER METER P PAVEMENT WV WATER VALVE INT. DATE PLANS PREPARED UNDER SUPERVISION OF FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY � �3 2 � PUBLIC WORKS NA ---- DATE: ' g t51 J N RIN E, P.E. DATE PLANNING NA OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL 'GEOID09'. R.C.E. NO.: C72279 DATUM: NAVD88 StP�yPrNowG�Jv 3/9/21 REVIEWER jQO 3/61 CITY ENGINEER DATE INSPECTOR KK S/A H PRIN P.E. EXP.: 6/30120 a � A P N 2 5 7- 0 2 0- 2 7 PROPERTY ��" --- LINE a SHEET 8, 92 10 FND 3 4" IP LS415 -- FND 2" IP RCE2957 -_--_ fr__ 15' WIDE SAN DIEGUITO IRRIGATION 1 DISTRICT EASEMENT RECORDED I I I I 1 6/10/1966 AS FILE/PAGE NO. 96007 I I I I I I I I I I I PROPERTY I ' --- I PROPERTY LINE LINE I Is I 15' EA SEMENT FOR ROAD AND INCIDENTAL PURPOSES RPOSES IN THE DOCUMENT RECORDED N l APRIL 19, 1963 AS INSTRUMENT NO. 146817 CQ I i O I I I I � I I � AAPN 256-340-31 ------------------ ----------- I L11 I I N I � AN EASEMENT FOR WATER PIPELINES AND i SHEET 3, 5, 6 11, 12 I INCIDENTAL PURPOSES, RECORDED JULY 31, , Q 1 1985 AS INSTRUMENT NO. 85-274415 OF OFFICIAL RECORDS. I I � ENGINEERING DIVISION APPROVALS RECOMMENDED: APPROVED: JES OWFNS DAR J. IM I CITEENGI D ER DA� 14 r ' II KEY MAP 1 "=60 - NOTES AND KEY MAP CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 14094-G 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: SHEET 2 OF 16 i N N O N C O U C O L O Q '1w _ _ 15' P L � ��— V I PARKING PA 24' _ 1 _ 15' DRIVE AISLE I PARKING 6" CURB 6 I l i— UNDER PAVEMENT, OVEREXCAVATE EX FILL SOILS TO DEPTH OF 12-IN BELOW THE EXISTING OR PLANNED GRADE, WHICHEVER IS LOWER, PER XISTING FILL GEOTECHNICAL RECOMMENDATIONS. 48"X48" OVERFLOW INLET PER PLAN (Q100) WITH ORIFICE PLACE PER DETAIL THIS SHEET 2'12" Imo_ TG 219.: 219.91 ° 218.5-\ WALL TYPE C PER `< SDRSD C-9 VARIES EX 216.9-219.0f ` GROUND e d _ 12" MIN d a e ' BW ELEV PER PLA 12" MIN 12" STORM DRAT PIPE PER PLAN v+ c 0 / 0 0 Q i N CHANGE NO. 0 0 N 2 0 0 IL N PA TW 219. SITE SECTION N.T.S. 15" w- a zw J J W C a z w a5 a cu _J 24" 6" CURB 10' PLANTER 0 PER SDRSD ARATE :1 EVENTS • I PA 15" z a J a. TG 216.58 w 36"X36" OVERFLOW INLET PER PLAN (Q100) o 9 42' WITH ORIFICE PLATE 2 J w PROPOSED BLDG PER ER DETAIL THIS SHEET U) z 3, SEPARATE PERMIT CLEANOUT 2" O z O F= BENCH 2" ABOVE INLET. W N 10" MAX LOCATION PER PLAN. O m 219.50 FFE = 220.0 12" URFACE PAD = 219.25 8" ONDING 2" 215. 3" F- MULCH (Q1 10) f' 12 MIN-1 r-CLEANOUT 4" 12- ABOVE INLET. SURFPROPOS ACE 3. - LOCATION PER PLAN GRADE PONDING (Q100) 3••1 S`OPE NDER PAVEMENT, OVEREXCAVATE I I I I SVOPE — I I EX FILL SOILS TO DEPTH OF 12-IN I 4 I I 3•� — BELOW THE EXISTING OR PLANNED GRADE, WHICHEVER IS LOWER, PER -I' GEOTECHNICAL RECOMMENDATIONS. 3" C18" MULCH 18" UNCOMPACTED BIORETENTION SOIL MEDIA (BSM) PER APPENDIX G.1 OF THE _ CURRENT COUNTY OF SAN DIEGO LOW IMPACT DEVELOPMENT HANDBOOK -`� STORMWATER MANAGEMENT STRATEGIES, CONSISTING OF 65% WASHED SAND, 20% �- =21"-: - _ SANDY LOAM, AND 15% COMPOST (5% ORGANIC MATTER). PERCOLATION RATE _ 4 - - 5-/HR MIN WASHED PEA GRAVEL FILTER COURSE " WASHED, OPEN -GRADED �4" CRUSHED ROCK �� m AMI��iCi�►n�n�n�n�n���n�n�n�n�nv� 0kvAVAAA rn���n�n�n�n�n�n�►�n�i.- • • - LA WASHED, OPEN -GRADED �'4" CRUSHED ROCK BUILDING FOOTPRINT, I PER 18" UNCOMPACTED BIORETENTION SOIL MEDIA BSM PER APPENDIX G.1 GEOTECHNICAL TO RECOMMENDATIONS. ( ) BACKFILL TO PAD OR FINISH OF THE CURRENT COUNTY OF SAN DIEGO LOW IMPACT DEVELOPMENT GRADES. HANDBOOK STORMWATER MANAGEMENT STRATEGIES, CONSISTING OF 65% WASHED SAND, 20% SANDY LOAM, AND 15% COMPOST (5% ORGANIC MATTER). PERCOLATION RATE = 5"/HR MIN XISTING NATIVE SUBGRADE SITE SECTION (BMP 2) 6 _ I ISID� EWA KI 2' h— 11.8 I 2' ISID� EWALKI 46.1' " PERFORATED SUBDRAIN PER PLAN PER DETAIL 1 SHEET 6 15 MIL PVC OR HDPE IMPERMEABLE LINER SITE SECTION BMP 1 ( ) AL N.T.S. — 6.3' WALL LENGTH WALL TYPE C PER SDRSD C-9 PROPOSED BLDG FFE = 220.0 12" FG 219.5 PAD = 219.25 2• .: a A. - KEY WALL INTO aWALL d.. d. ' .. •. .^ g ' A — — — PER DETAIL 9 ON SHEET 7 r<. a a _ - p • a' — — UILDING AND FOOTING . ' aKEY WALL INTO BUILDING F Z. - I = — — PER SEPARATE PERMIT LE d d - ' . Yd . °, . ' a • ' PER DETAIL 9 ON SHEET 7 �. . 'a . WALL TYPE C PER d ♦ d SDRSD C-9 REMOVE EX FILL SOILS TO EXPOSE VARIES <: .a ' 1_ IIII 1' MIN VERY OLD PARALIC DEPOSITS OR 216.5t TORREY SANDSTONE, EXTENDING LATERALLY OUT 5-FT FROM BUILDING FOOTPRINT, PER 12" MIN `' GEOTECHNICAL RECOMMENDATIONS. ° BACKFILL TO PAD OR FINISH GRADES. XISTING FILL BW 215.0 215.1 OOTING PER 12" STORM DRAT SEPARATE PERMIT PIPE PER PLAN SITE SECTION N.T.S. DESCRIPTION APPROVED DATE BENCHMARK SR 3 9 21 FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL 'GEOID09'. DATUM:NAVD88 N.T.S. 6' PWALq 8 - 1 SEE SHEETS 13, 14, 15, & 16 EX GROUND PROPra ' WATER LINE WATER LINE EMOVE EX FILL SOILS TO EXPOSE VERY OLD PARALIC DEPOSITS OR TORREY SANDSTONE, EXTENDING LATERALLY OUT 5-FT FROM UNDER PAVEMENT, OVEREXCAVATE EX FILL BUILDING FOOTPRINT, PER GEOTECHNICAL RECOMMENDATIONS. SOILS TO DEPTH OF 12-IN BELOW THE XISTING BACKFILL TO PAD OR FINISH GRADES. EXISTING OR PLANNED GRADE, WHICHEVER IS LOWER, PER GEOTECHNICAL RECOMMENDATIONS. PLATE 3" -ESS (TYP) UT (TYP) F C�7 PROPOSED BLDG FFE = 225.0 PAD = 224.25 FILL ` WHERE A CUT/FILL TRANSITION LINE EXTENDS BENEATH A \PROP PROPOSED STRUCTURE, THE CUT PORTION SHALL BE UNDERCUT TO A DEPTH OF 2 FEET BELOW AND 5-FT BEYOND PROPOSED SEWER LA FOUNDATION OR TO A DEPTH ONE-THIRD OR MORE OF THE DEEPEST FILL DEPTH BENEATCH STRUCTURE, WHICHEVER GREATER, AND THEN FILLED, PER GEOTECHNICAL RECOMMENDATIONS. SITE SECTION N.T.S. RIFICE PLATE: MIN. SQUARE DIMENSIONS 1' GREATER THAN PIPE DIAMETER. HOT DIP GALVANIZE PLATE AFTER HOLES HAVE BEEN DRILLED NFLOW PIPE RIFACE DIAMETER: BMP 1: 1.5" BMP 2: 0.75" r- 1/2" MAX BMP SPECIAL INSPECTION NOTE: DIAMETER NOTE: HOLE (TYP) ORIFICE & FLANGE CONNECTION TO CONCRETE SHALL BE FILLED WITH 30 DUROMETER NEOPRENE RING FLOW CONTROL ORIFICE PLATE N.T.S. AS -BUILT APPROVALS "��"'"C" �': ""`"l�" ter: `'"t`'�t" �Y: ENGINEERING DIVISION APPROVALS BW BW JP 1�i3 x i INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: e I .s I R.C.E. NO.: C72279 OHN RIN E, P.E. EXP.: 6/30/20 REC(IMMENDED: AP ROV JESS OW -.NS EDWARD J IMMER >®l� CITY E G ER DATE DA E PUBLIC WORKS NA ---_ JCqN RIN , P.E. DATE Steve, Nowak 3/9/21 PLANNING NA ---- REVIEWER JQO 3�6I CITY ENGINEER DATE INSPECTOR KK 3/A SEWER LINE SPECIAL INSPECTION OF THE BMP FACILITIES BY A LICENSED CIVIL ENGINEER IN THE STATE OF CALIFORNIA IS REQUIRED DURING CONSTRUCTION. PRIOR TO OBTAINING BUILDING OCCUPANCY, AN INSPECTION REPORT SHALL BE SUBMITTED WITH THE FINAL GRADING CERTIFICATION TO THE ENGINEERING DIVISION VERIFYING THE SIZE AND DEPTH OF THE EXCAVATION, GRAVEL AND ENGINEERED SOIL DEPTH AND MATERIAL, STORM DRAIN PIPE, OVERFLOW AND OVERALL FUNCTION OF THE FACILITIES PER THE APPROVED GRADING PLAN. THE INSPECTION REPORT SHALL INCLUDE ANY PERTINENT INFORMATION INCLUDING MATERIAL RECEIPTS, SURVEY DATA, INSPECTION DATES, ETC. IN ORDER TO DETAIL THE CONSTRUCTION OF THE DRAINAGE FACILITY. SPECIAL INSPECTION REPORT PREPARED BY _JOHN PRINCE, PE DATED 10%Q2020 __ IS ON FILE WITH THE ENGINEERING DIVISION. Y It - SITE SECTIONS AND BASIN DETAILS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 14094-G 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: 16-147 CDP SHEET 4 OF 1 a rn N O 6 O -1 N ao 00 0 rn r 0 N N 0 N 0 N c 0 c 0 0 rn 3 v a CD 1 ca I 0 E `v a rn c 'v v 0 0 / 0 N It 0 1 N 0 51 0 a N BIOFILTRA BASIN SEI PER SITE D ON SHE N.T.S. TW 217.2E BW 211.25 EG 214.04 CURB OUTLET 7-)p, Q100=4.13 CFS V100=6.3 CFS �p P, 2 ' I I I I I i I I I I I I I E I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I MATCH EX GRADE (FG 236.60t) EX AC I � I I MATCH EX PAVEMENT I L aaa P SD HEADWALL L. p L. p L. G` FINISHED GRADE PER SDRSD D-34 PER PLAN 6" CURB L D L p � MATCH EX GRADE c g. PLAN 3''�X �— EX AC SCALE 1 "=5' STORM DRAIN OUTLET 5 2.5 0 SCALE: 1 "=5' 10 20 ,NGE NO. DESCRIPTION APPROVED DATE BENCHMARK 2 AS -BUILT SIRN 3/9/21 FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 AS -BUILT APPROVALS SECTION TYPICAL DRIVEWAY TRANSITION INT. DATE _ PUBLIC WORKS NA __ J N RIN E, P.E. DATE PLANNING NA ---- Steve, Nowak 3/9/21 REVIEWER JQO 3/61 CITY ENGINEER DATE INSPECTOR KK 3/61 N.T.S. DESIGNED BY: DRAWN BY: CHECKED BY: BW BW JP PLANS PREPARED UNDER SUPERVISION OF DATE: S li /q jr f R.C.E. NO.: C72279 OH PRI CE, P.E. EXP.: 6/30120 e� 24.3' I MATCH EX GRADE (FG 236.40f) FINE GRADING AND PAVING PLAN n NOTE: ALL ITEMS PER PAVING DETAIL SHEET UNLESS OTHERWISE NOTED CONSTRUCTION NOTES 1O PROTECT EX BERM O 6" CURB PER SDRSD G-01 3Q 6" CURB AND GUTTER PER SDRSD G-02 ® FLUSH EDGE 5J ADA RAMP WITH HANDRAILS PER SEPARATE PERMIT ©STRIPING AND SIGNAGE PER SEPARATE PERMIT 7O SLURRY SEAL FULL ROAD WIDTH AT COMPLETION OF WORK ®TYPICAL DRIVEWAY TRANSITION PER SECTION A ON SHEET 6 (9)PEDESTRIAN CONCRETE PAVEMENT PER DETAIL 2 ON SHEET 7 10 ASPHALT PAVEMENT PER DETAIL 3 ON SHEET 7 11 ASPHALT PAVEMENT SAWCUT TRANSITION PER SDRSD G-11 12 RIBBON GUTTER PER DETAIL 7 ON SHEET 7 13 12" WIDE PEDESTRIAN CONCRETE PAVEMENT STRIP PER DETAIL 8 ON SHEET 7 14 ROOF DRAIN DOWNSPOUTS PER SEPARATE PERMIT 15 AWNING POSTS PER SEPARATE PERMIT 16 SEGMENTAL WALL PER SHEETS 13, 14, 15, & 16 17 LIGHT POLES AND FOUNDATIONS PER SEPARATE PERMIT 18 ROCK MULCH SWALE PER DETAIL 1 ON SHEET 6 19 BROW DITCH PER SDRSD D-75 ©p CONCRETE TURNDOWN WITH FENCE PER ARCHITECTURAL/STRUCTURAL PLANS MATCH EX XPAVENT(P 233.63 MATCH EX PAVEMEN' 10 5 0 ® ENO a so�� _� SCALE 1"� —' n- Amor 10 SCALE: 1 "=10' O1 ROCK MULCH TO BE SANTA FE COBBLE (SFC) OR EQUAL. VENDOR: SOUTHWEST BOULDER AND STONE OR APPROVED EQUAL. ROCK SIZEM 4" TO 8". BACKFILL VOID AREAS TO COVER VIEW OF WEED BARRIER WITH 1" TO 2" SIZE SFC. MINIMUM DEPTH 12" AT CENTER LINE OF SWALE. ROCK SHOULD NOT BE PLACED ON TOP OF FINISH GRADE. 20 SWALE LIMITS, 18" TO 24" WIDTH. OWEED III BARRIER. VENDOR: DEWITT PRODUCTS, MODEL NO., 12 YEAR EARTHTONE FABRIC OR EQUAL. EXTEND FABRIC 6" BEYOND EDGE OF SWALE LIMITS. �4 MINIMUM SLOPE 1 % MAINTAIN DRAINAGE AWAY FROM BUILDING OWOOD MULCH, AS REQUIRED. OAT BASE OF DOWNSPOUTS MAINTAIN CONTINUOUS 12" DEPTH OF ROCK, 2" SQUARE. DETAIL 1 - ROCK MULCH SWALE ENGINEERING DIVISION APPROVALS RECO MENDED- APP V D- JESS [ NS 17 WARD J. MER CITY _NGIN R DATE -I 20 30 CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 14094-G 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: 16-147 CDP SHEET 6 OF 16 rn 0 N N 0 EX PAVEMENT NEW PAVEMENT _ SECTION PER PLAN w z NOTE: STEEL REINFORCEMENT (NUMBER 3 BARS 4" ASPHALTIC CONCRETE PAVEMENT ® 24" ON CENTER EACH DIRECTION MINIMUM) D a 1.5" MIN PLANE AND I0 14- PORTLAND CEMENT CONCRETE* o OVERLAY. PROVIDE A 1' MIN < D a CLASS 520-C-2500, MOR=600 4" FOR PASSENGER/MAINTENANCE VEHICLES SMOOTH TRANSITION 2" COMPACTED SUBGRADE (95% MIN) 6" FOR FIRE ACCESS ROAD JCLvA S I AGGREGATE AS L JOINTS AND SPACING OTHERWISE SPECIFIED BY ARCHITECT) TYPICAL DETAILS (UNLESS \\\\ \\12" COMPACTED SUBGRADE (95%\ MIN )\ \ \ � EXISTING BASE p o *ALL VALUES ARE PRELIMINARY. CONTRACTOR IS RESPONSIBLE FOR FINAL PAVEMENT SECTIONS AS DETERMINED BY GEOTECHNICAL ENGINEER AFTER R-VALUE TESTING AND TEST OF COMPLETED SUBGRADE. REBAR REINFORCEMENT AS REQUIRED PER SPEC. 1 NOT USED 2 PEDESTRIAN CONCRETE PAVEMENT SECTION 3 ASPHALT PAVEMENT SECTION 4 ASPHALT PAVEMENT SAWCUT TRANSITION MATCH FLUSH TO EX WITH EXPANSION w JOINT (" MAX) 1/2" (PAVEMENT) PROP CONC FINISHED 0 w m 1/4" MIN - 1/2" EX CONC SURFACE 1/4" RECESS ----MAX (SIDEWALK) -�- 3/16 PORTLAND CEMENT CONCRETE* ¢� w � 1/4" 1 4"R TYP 1/4" r 1/4"R (TYP) / ( CLASS 560-B-3250, MOR=600 18" 18" SURFACING OR FINISHED 12" -�- ,( 1 e GRADE PER PLAN j� j ^ a a , - ° a PAVEMENT OR 1 JOINT FILLER OR OMODTBAR,R30S ON 1 CENTER, CENTERED 2 PREFORMED TYPE "B" BACKER ROD �� \� JOINT FILLER VERTICALLY IN JOINT FILLER ELASTOMERIC PER BASE MATERIAL AND SEALANT PAVEMENT SECTION AND SEALANT MANUFACTURERS TRAVERSE WEAKENED PLANE RECOMMENDATIONS JOINTS ® 20' O.C. EXPANSION JOINT CONTACT JOINT WEAKENED PLANE JOINT JOINT FILLER AND SEALANT NOTE: UNLESS OTHERWISE SPECIFIED BY ARCHITECT: • CONSTRUCT CONTACT OR KEYED JOINT AT CONNECTION TO EXISTING CONCRETE OR END OF POUR. • CONSTRUCT WEAKENED PLANE JOINTS AT 15-FT MAX INTERVALS BOTH WAYS PER GB SPEC 201-3.5 • CONSTRUCT EXPANSION JOINTS AT 45-FT MAX INTERVALS BOTH WAYS, AND ADJACENT TO STRUCTURES, PER GB SPEC 201-3.5 • COORDINATE JOINT LOCATIONS TO ALIGN WITH BUILDING CORNERS, ENDS OF WALLS, AND OTHER STRUCTURES STD DWG REF: G-10, G-18, G-19, G-20, G-21 5 CONCRETE JOINTS 7 RIBBON GUTTER 8 12" PEDESTRIAN CONCRETE PAVEMENT STRIP W J W U m O U I--- w m AC PAVEMENT OR a D 0.5" CONCRETE PER PLAN VOLCLAY WATERSTOP -RX 101 6"w U 0.5" RADIUS (TYP) 6" CURB PER PLAN OR APPROVED EQUAL / FACE OF PERPENDICULAR WALL, WHERE OCCUR FINISHED GRADE PER PLAN / CONCRETE PER PLAN ao �12 pN 1 i x3i" KEY A. 2 WEAKENED PLANE JOINT AT 15' O.C. NOTES: 1. CONCRETE SHALL BE 520-C-2500. 2. SLOPE TO OF CURB 1 /4" PER FOOT IN DIRECTION OF FLOW. 9 WALL KEY 10 FREESTANDING CURB (6) 11 CURB (0') 12 CURB TRANSITION (6" TO 01) PAVING DETAILS CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. BW BW JP FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO 13 zi INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE:1.S 1 RECOMMENDED: APP O / �' GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS p __ AS-BUILT._i SRN 3 9 21 PUBLIC WORKS N f} ____ - �- -- USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) JES. - F NS DWARD J. IMMER COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 14094-G J N RIN -, P.E. DATE PLANNING NA ---- AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 Ste�ve/No-wak. VV21 R.C.E. NO.: C72279 JOH PRIN E, P.E. EXP.: 6/30/20 CI Y ENGI ER � 1-1 l ��, i �' 311 SAXONY LANE - APN 256-340-31-00 REVIEWER jQO 3/61 CITY ENGINEER DATE INSPECTOR 1CK 3/G� DATE I PLANNING CASE NO: 16-147 CDP SHEET 7 OF 16 As- 00 N 0 :t. cp .P z � \ o°+ O o m r — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — �a) 0- m D I EASEMENT FOR ROAD AND INCIDENTAL i� 1 0) V) I \ o (A M D R I I PURPOSES IN THE DOCUMENT RECORDED I e o> z r Z I I APRIL 19, 1963 AS INSTRUMENT NO. I e Z m o o o i APN 2 5 6 -- 3 3 O- 6 2 I 146817 OF OFFICIAL RECORDS. � e e � �• I � e I �c:mmo�cmi�o I _ D np z D Z I EASEMENT FOR ROAD AND INCIDENTAL PURPOSES IN THE o z -i v I DOCUMENT RECORDED APRIL 19, 1963 AS INSTRUMENT N0. 1 e cn o� F m o I 146817 OF OFFICIAL RECORDS. n I \\ 1 ee ---------- I I 1 \ ------- ---------------------- ----------------------------------------------® �.—.-- -- I 1 e —® ®_--__ \ eee STA 12+64.14 / — — �I-3+ — — — — — — _ _ _ -- -------------------- ------------------- e 45' BEND, _ ---1- ---- — — — — — — —------- t`- m — — ------ 1� oO--_ _ — — — — —— — — — — 4 ` ee - --- -- -- - -- - -yk--------•TB 34 -SF MIN � � \ e _ ---------------- \ / / r------------------------------------- _ nA R_ -- ------ ®-_-------- ---------------- / -------------------- i - - ----------------------------- / SDWD EASEMENT PER DOC-- o94 / 1 / RECORDED -A- 10M > ee — I I 1 SHEET ee STA 11 +96.87 / 0 / < FH LAT TB4.2-SF MIN/ O e\e O \ 1 WIDE SAN DIEGUITO IRRIGATION\ • ` // / APN 2 5 6 - 3 40 - 31 DISTRICT EASEMENT RECORDED 6/10/1966 AS FILE/PAGE NO. 96007 / \\ 4 L n EX WATER ACP 2" BLOW OFF PER WB- 4 / v / / // TRANSITION 0^ OUPLING TEST PL FOR �.<. Z / SDWD WATER NOTES FOR IMPROVEMENT PLANS: JOINT RESTR NG CHLO TION AND SYS PR URE TESTING (1) WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING (17) WATER CONNECTIONS TO COMMERCIAL DEVELOPMENTS SHALL HAVE AN 8" PVC (4' MIN) TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES STANDARDS APPROVED BACKFLOW DEVICE INSTALLED TO THE DISTRICTS SATISFACTION AND CURRENT \,- n z / // / �S• COMMITTEE (WASC). THE CONTRACTOR SHALL AND HEREBY DOES GUARANTEE ALL WORK WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. BACKFLOW DEVICES ARE 8" FLG X PO RWGV 2" BLOW OFF PER WB-06 m FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE. TO BE INSTALLED DIRECTLY OUTSIDE CITY OR COUNTY RIGHT-OF-WAY OR OUTSIDE PER WV-02 N / / // WATER DISTRICT EASEMENT. REPAIR, MAINTENANCE AND ANNUAL TESTING OF BACKFLOW NO 1 (2) THE CONTRACTOR SHALL NOTIFY THE DISTRICT'S INSPECTION DEPARTMENT 48 DEVICE ARE RESPONSIBILITY OF OWNER. 8"X8"X8" FLG TEE V5 ED HOURS IN ADVANCE OF BEGINNING WORK TO ARRANGE FOR INSPECTION OF PROJECT. W/ THRUST BLOCK SDWD EASEMENT PER DOC_( THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (18) MINIMUM HORIZONTAL SEPARATION OF 10 FEET REQUIRED BETWEEN FIRE 16.1-SF MIN Q���®ig HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. b 1�D1�L') (760) 633-2709. ALL WORK PREFORMED WITHOUT BENEFIT OF INSPECTION WILL BE �`"`\•� y / RECORDED-&V(p , 7A19 '0 SUBJECT TO REJECTION AND REMOVAL. 8" PVC (4" MIN) (19) UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING (3) THE CONTRACTOR WILL BE REQUIRED TO SCHEDULE A MANDATORY WATER SERVICES. JOINT RESTRAINT SYST 22° BEND PRE -CONSTRUCTION CONFERENCE WITH THE SAN DIEGUITO WATER DISTRICT INSPECTOR OI TRANSITION COUP _8" FLG X FLG W/THRUST BLOCK 20 CONTRACTOR AND DEVELOPER ARE RESPONSIBLE TO RELOCATE ANY EXISTING " RWGV PER WV-0 (6.3-SF MIN) PRIOR TO COMMENCEMENT OF WORK ON WATER IMPROVEMENTS. PHONE: (760) ( ) R EX 8 WATER / 633-2709. WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) THAT ARE / EFFECTED BY THEIR PROJECT. �- o / / (4) UNLESS OTHERWISE NOTED, ALL CONNECTIONS TO EXISTING MAINS WILL BE MADE BY A �'` •° �� / / THE CONTRACTOR, UNDER THE SUPERVISION OF SAN DIEGUITO WATER DISTRICT, AFTER (21) CONTRACTOR TO SUPPLY DOCUMENTATION SHOWING THAT ANY ASBESTOS / PAYMENT OF THE ESTIMATED COST BY THE DEVELOPER. WATER PIPES REMOVED FROM THE GROUND WERE DISPOSED OF IN A MANNER N.T.S. ACCEPTABLE TO THE SAN DIEGO COUNTY WASTE DIVISION. \ y. 60? r / TOP OF PIPE PROFILIO IS 48 ANDGRADES BELOW CEONTERLINOWN ON E FINIISHTHE WATER MAIN GRADE OF STREETPROFILE, (22) USE THE FOLLOWING VARIOUS COMBINATIONS OF PLAIN END PIPE LENGTHS WITH j / N x� / �� HIGH DEFLECTION COUPLINGS AND INTEGRAL BELL END PIPE FOR CURVED ALIGNMENTS IN / 15-FOOT WIDE SAN DIEGUITO IRRIGATION DISTRICT EASEMENT, N ^O (6) ALL SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS. BOTH HORIZONTAL AND VERTICAL DIRECTIONS. DO NOT BEND PIPE BETWEEN COUPLINGS. ; RECORDED 6/10/1966, FILE/PAGE NUMBER 96007 SAW CUT INTEGRAL BELL END OF STANDARD PIPE AND BEVEL END FOR USE WITH p // s•0,__� 0 \� 7 CONTRACTOR TO FURNISH ONE INCH COPPER WATER SERVICE AND METER BOX FOR DEFLECTION COUPLINGS. USE 9.5-FOOT PLAIN END PIPE LENGTHS WITH DEFELCTION / A ( ) COUPLINGS FOR ALL RADII BETWEEN 140 FEET TO 270 FEET. USE 19-FOOT PIPE TB. 13.2-S ib1 1 EACH RESIDENTIAL LOT. LENGTHS WITH DEFELCTION COUPLINGS FOR ALL RADII BETWEEN 270 FEET TO 560 FEET. / / / 6Jc USE AND INTEGRAL BELL END PIPE LENGTH JOINED TOGETHER WITH A 19-FOOT PLAIN 6 weT TAB ONNEc_T1otN -I-o i 3 (8) CONTRACTORS SHALL ACQUIRE A TRENCHING PERMIT FROM THE CALIFORNIA DIVISION r / N ?uguC WATR MAIN 4�E'R WAS END PIPE LENGTH TO FORM A CHORD. USE DEFLECTION COUPLINGS ON EACH END OF � 8 OF SAFETY FOR ALL TRENCH WORK. THE CHORD AND CONTINUE THIS COMBINATION THROUGH THE CURVED ALIGNMENT FOR ZO �� / SP£c 5£c-riov-1 ISOoo- 1.06 e / ALL RADII BETWEEN 560 FEET TO 1,150 FEET. PIPE LENGTHS SHORTER THAN 9 FEET 4 trip 2fes.®*% T$ 24.2-SP MIT4 3 (9) INSTALL FIRE HYDRANTS 2.5 FEET FROM FACE OF CURB, IF NO SIDEWALK EXISTS, WILL NOT BE USED UNLESS SPECIFICALLY AUTHORIZED THE BY THE DISTRICT'S t OR 7 FEET FROM FACE OF CURB WHERE SIDEWALK EXISTS OR WILL BE CONSTRUCTED. REPRESENTATIVE. �, \ SDWD EASEMENT PER OD A ° I f DOC_2e -sZ o94 0j C�j (10) PROVIDE AIR RELEASE ASSEMBLIES AT ALL HIGH POINTS IN WATER MAIN.p (23) CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD �1` I �� RECORDED_&Vb,_ajp 2p11 BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM N (11) CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT FROM THE CITY OF EFFECT JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW THE DISTRICT SHALL REQUIRE 04 ENCINITAS FOR ANY EXCAVATION WITHIN EXISTING CITY RIGHTS -OF -WAY. ALL MATERIALS TO BE NO -LEAD BRASS PARTS. (12) THE DISTRICT REQUIRES THAT COMPACTION TESTS BE TAKEN WHERE WATER LINES I I \ \ ARE INSTALLED WITHIN EXISTING COUNTY RIGHTS -OF -WAY, CITY OF ENCINITAS (24) ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC-17 OR WC-18. I I a. RIGHTS -OF -WAY, OR PRIVATE EASEMENTS, AND THE RESULTS APPROVED BY THE CITY �„ T N OF ENCINITAS, BEFORE THE WATER LINES ARE ACCEPTED AND A COPY SENT TO THE SAN (25) WATER SERVICES TO BE ABANDONED THAT ARE CONNECTED TO PIPELINES THAT I s DIEGUITO WATER DISTRICT OFFICE. WILL REMAIN IN SERVICE SHALL BE DISCONNECTED T o A THE CORPORATION STOP, SHALL I I -1 j (13) PRIOR TO AWARDING WATER LINE CONTRACT, OWNER SHALL ADVISE PROSPECTIVE HAVE THE CORPORATION STOP REMOVED AND SHALL HAVE A BRASS PLUG INSTALLED; I \ £Of� J OR BE ABANDONED AS DIRECTED BY THE SDWD INSPECTOR. > CONTRACTORS TO OBTAIN AND REVIEW CURRENT WATER AGENCIES STANDARDS o`" COMMITTEE (WASC) SPECIFICATIONS. I - / 11 DATER CONSTRUCTION NOTES I 1 v (14) FILL AREAS MUST BE COMPACTED TO 90%, PRIOR TO PIPE INSTALLATION. / / I I Eel (DINSTALL CONCRETE THRUST BLOCKS PER WAS SD WT-01 I L - / o (15) APPROVAL OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE Q INSTALL FIRE HYDRANT PER WAS SD WF-01 WITH BOLLARDS. EHT I - -- - O '- A REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR FLAW CfE L�-Ev. 51-IA�L BF 6" t t" FiloM -MP OF S�.A�. N NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. Q INSTALL 6- GV WITH VALVE SUPPORT BLOCK PER WAS SD i / a 13.2-SF MIN L------------- o (16) ALL EXISTING FACILITIES WHICH MAY EFFECT FINAL DESIGN, I.E., LINE CROSSINGS, LINE PARALLELING, OR PROPOSED CONNECTION SHALL BE FIELD WV-02 AND WT-02 ®br Pvc- C��o®�Gc3v5,�a`\^� ifZEN�1� RES�RF�IN6 I FLA ELE N I „ „ VERIFIED. I SHALL t1 j 20 10 0 20 40 60 ALL EXISTING OR PROPOSED UTILITY CROSSINGS WITHIN 10 FEET OF PROPOSED WATER �Q.� WAS SC V�P'o2 I F TOP 0 AB c MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS I I +• UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER N SCALE: 1 "=20' DISTRICT. I OVERALL WATER PLAN I U CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. BW BW JP t-w-m 10N Lo INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APP OVE GRADING PLAN FOR: AS -BUILT SI'R / /21 E 2 FIELD SURVEY CONDUCTED BY COUNTY OF �3 2 / DATE: I,S u j ADMINISTRATION AND HORTICULTURE BUILDINGS PUBLIC WORKS NA ____ SAN DIEGO USING THE CONTINUOUSLY COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 14094-G JOH P INC P.E. DATE OPERATING REFERENCE STATION CORS , PLANNING Nfl_ JESS OVVI f WARD J. \ ER AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 St-evelNo-wak, 3/9/21 R.C.E. NO.: C72279 CITY ENGIW R 311 SAXONY LANE - APN 256-340-31-00 REVIEWER JQO 3/q CITY ENGINEER DATE INSPECTOR KK 3/� SHEETS OF 1 JO PRIN E, P.E. EXP.: 6/30/20 SATE j D E PLANNING CASE NO: 16-147 CDC I rn r O N r O N v N C O 0 C O v I two •, • #^.:_ i ! NY r ! ` "• ♦ ,# yr; ♦ f # :; i •i # ' ' ! , • � Y # r .- , Y • a i - . _ • ! • a . a ; ! R • Y :. ; Y ' ^ " ' r • r r a r • ♦ r , i ^.- • r . , Y w • � 4 w 1 w , Y 1 ■ ♦ r 1 A 600 M SHEET FLOW_ LESS THAN 0.4 HA (1 AC) Hal*; GEOTEXTiLE BLANKET DRAiN INLET SECTION A —A LT FENCE PER SC-01 150 MM MIN OVERLAP AT ENDS OF SILT FENCE. A —GEOTEXTILE BLANKET SILT FENCE PER SC-01 1. FOR USE IN AREAS WHERE GRADING HAS BEEN COMPLETED AND FINAL SOIL STABILIZAT11 AND SEEDING ,R PENDING. 2. NOT : PAVED 3. NOT • :_ ►. SC-1 C� STORM DRAIN INLET PROTECTION c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE. � ` :III=III=III=III ` ` —III—I i l—III—i 11=1 11= A WATER- TO WASH NS-2 FTC-1 DEWATERING FILTRATION — Dw Dw STABILIZED CONSTRUCTION ENTRANCE 2. CONDITIONING THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED. -_---- —I-1 i - I I-III-III-III—III=11 % -III ;.I11--I -I II -III -III -III- II(_III- WHEELS IF NECESSARY 0 TC-2 CONSTRUCTION ROAD STABILIZATION b• THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS LEACHING OR FOR GROWTH. SILT FENCE o I TC-3 ENTRANCE / EXIT TIRE WASH NO SCALE SC-1 SOURCE CONTROL BMPS 4.2.1 PREVENTION OF ILLICIT DISCHARGES INTO MS4 4.2.2 STORM DRAIN STENCILING OR SiGNAGE 4.2.3 PROTECT OUTDOOR MATERIALS STORAGE AREAS FROM RAINFALL, RUN-ON, RUNOFF, AND WIND' DISPERSAL 4.2.4 PROTECT MATERIALS STORED IN OUTDOOR WORK AREAS FROM RAINFALL, RUN-ON, RUNOFF, AND WIND DISPERSAL 4.2.5 PROTECT TRASH STORAGE AREAS FROM RAINFALL, RUN-ON, RUNOFF, AND WIND DISPERSAL 4.2.6 ADDITIONAL BMPS BASED ON POTENTIAL SOURCES OF RUNOFF POLLUTANTS SITE DESIGN BMPS 4.3.1 _] MAINTAIN NATURAL DRAINAGE PATHWAYS AND HYDROLOGIC FEATURES 4.3.2 CONSERVE NATURAL AREAS, SOILS, AND VEGETATION 4.3.3 MINIMIZE IMPERVIOUS AREA 4.3.4 MINIMIZE SOIL COMPACTION 4,3.5 IMPERVIOUS AREA DISPERSION 4.3.6 RUNOFF COLLECTION 4.3.7 LANDSCAPING WITH NATIVE OR DROUGHT TOLERANT SPECIES E. ATDROSEEDED AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT # PERMANENTLY , LANDSCAPED , R • • FOR • AREAS WHERE HYDROSEEDING IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED r ALL BONDSRELEASED. F. PRIOR TO THE ACCEPTANCE OF THE HYDROSEEDED AREAS BY THE COUNTY RESIDENT NGINEER, A CERTIFICATION REPORT MUST BE SUBMITTED BY A REGISTERED.LANDSCAPE ARCHITECT, STATING# HYDROSEEDING DONE ACCORDING TO THE PROJECT SPECIFICATIONS AND THAT THE GROWTH IS ADEQUATELY ESTABLISHED TO PREVENT EROSION. G. IT IS THE INTENT THAT THE HYDROSEED MIX BE BEFOREJUST Y - OCTOr THE RAIN AFTER THE FIRST RAIN IN ER AND NO LATER THAN JUST AFTER H. ALL DISTURBED SLOPES TO BE HYDROSEEDED UNLESS OTHERWISE NOTED. 1. VEGETATION STABILIZATION (PLANTING OR HYDROSEEDING) MAY BE INSTALLED BETWEEN MAY 1ST AND AUGUST 15TH. SLOPE IRRIGATION MUST BE IN PLACE AND TO BE OPERABLE FOR SLOPES >3'. VEGETATION MUST BE WATERED AND ESTABLISHED PRIOR TO OCTOBER 1ST. THE OWNER SHALL SUPPLEMENT VEGETATION f_ BARK • Y MULCH :.. • i • 1ST IF VEGETATION ESTABLISHMENTDOES NOT OCCUR BY HAT DATE.•O;N CONTROL MEASURES• BE USED WHILE LANDSCAPING BEING ESTABLISHED. ESTABLISHED ! 1 : OF i MATURE .Y ROOTS . UNIFORM •1 VEGETATION - COVERAGE , OF r . OF THE NATURAL VEGETATIVE COVERAGE OR MORE ON ALL DISTURBED AREAS. J. ALL SLOPES OVER THREE FEET MUST HAVE ESTABLISHED VEGETATIVE COVER PRIOR li FINAL PERMIT Y.: APPROVAL 3 BAGS HIGH MAX.) EXISTING EDGE 2 BAGS HIGH MIN.) OF PAVEMENT GRAVEL BAG CHECK DAM NO SCALE -� SC-6 IN DRAIN INLET PROTEMIFION TYPE__ NO SCALE SC-?0 � ---USE GRAVEL BAGS, SPILLWAY% STRAW BALES OR OTHER APPROVED METHODS TO CHANNBASINASZREQUIREDF TO 00 0 O OHO %" - 3" COURSE AGGREGAi�O � d (6'° THICK MIN.} 0 12 MIN. �rn RUNOFF DIVERSION RIDGE NOTE: ALL AREAS OF SIGNIFICANT VEHICLE TRAFFIC (SITE ENTRANCES, ACCESS ROADS, PARKING LOTS, ETC.) SHOULD BE STABILIZED IMMEDIATELY AFTER GRADING TO PREVENT EROSION AND CONTROL DUST. SiTE ENTRANCES AND EXITS ARE ESPECIALLY IMPORTANT. USE GRAVEL APPROACHES TO LIMIT TRACKING OF SEDIMENT OFFSITE. STABILIZED CONSTRUCTION ENTRANCE NO SCALE TC-1 _v c� r .y +�, y rr rrrr/rrr w a.R rrrr/r rr rrrrr 12 C�` /rfirr/ r� r� r`rr ri r NOTE: INSTALL FIBER ROLL y /rirr, rri/rirrirrrr � ALONG A LEVEL CONTOUR. rri rr rr rr /r /r r y r ///rr rrrr/rr/rrrrr/ / -�l rri r�/� //r r �! y � y Fiber rolls ` r / ri /irrirrirri /r, VERTICAL SPACING r/rrrrrrrrrrr/r,!rr MEASURED ALONG THE rrrrrr/rrrrr y FACE OF THE SLOPE / VARIES BETWEEN -INSTALL A FIBER ROLL NEAR 2.4 M AND 6.0 M -- '- SLOPE WHERE IT TRAh151TI0N INTO A STEEPER SLOPE TYPICAL. FiDEP ROLL INSTALLATION -----_..._� NO SCALE. E SL a5 SLOPE V''gR'-ti 0 T E E c 19MMX o E 19MM WOOD STAKES MAX 1.2 M SPACING ENTRENCHMENT DETAIL NO SCALE SC-5 1=PnQ1C1A1 rnkIT0n1 AInTlI CHANGE NO. 2 DESCRIPTION APPROVED DATE BENCHMARK FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION i ) CORS AND THE NGS GEOID tv10DEL'GEOID09`. DATUM: NAVD88 _ _ AS -BUILT APPROVALS INT. DATE l/l3/21 PUBLIC WORKS NA --- ---------- J N Riry P.E. DATE __� PLANNING Nit Stewe/NOWA�cr _3/9/21 REVIEWER JQO 3_q CITY ENGINEER DATE INSPECTOR KK 3/q DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS_ RECO MENDED: APP O � �ft E EDWARD J. JESSWENS MER / CIT ENG[P` R Q�jZ /�q— Q ii DATE // F DAP1E - CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: 16-147 CDP -------- --- --- DRAWING NO. . 14094- BW BW JP PLANS PREPARED UNDER SUPERVISION OF DATE: � tL 6°j R.C.E- NO-: C72279 — OH PRIN P.E. EXP.: 6/30120 AS -BUILT SRN 3 9 21 — SHEET 11 OF 16 DESILTING BASIN NOTE 1. BIOFILTRATION BASINS SHALL BE EXCAVATED AND USED AS DESILTING BASINS DURING CONSTRUCTION. THE SILT SHALL BE COMPLETELY REMOVED AND THE BIOFILTRATION BASINS COMPLETED ONCE FINAL SITE STABILIZATION IS ACHIEVED, PRIOR TO OCCUPANCY AND/OR FINAL. APN 256-340-41 PROVIDE INLET PROTECTION PER SC-6/SC-8 AT NEAREST DOWNSTREAM INLET APN 256-340-43 pxll tl=f SCALE: 1 "=20' SCALE: 1"=20' .N EROSION CONTROL PLAN DESCRIPTION APPROVED DATE AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY:BENCHMARK DIVISION APPROVALS CITV OF ENCINITAS -DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. BW BW JPENGINEERING FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 13 Z 1 - 1 INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: $ 5 R.C.E. NO.: C72279 HN IN P.E. EXP.: 6/30/20 RECOMMENDED: APP O E . �� JES O E S EDWARD J. MMER CITY ENGI ER 1i1�1 i 2Z U DATE DA E GRADING PLAN FOR: ADMINISTRATION AND HORTICULTURE BUILDINGS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 311 SAXONY LANE - APN 256-340-31-00 PLANNING CASE NO: 16-147 CDP 14094-G LCHANGE AS -BUILT RN 319121 PUBLIC WORKS NA _-- JO N RIN -, P.E. DATE 3/9/21 PLANNING NA __ . REVIEWER JQO 3/GIca� CITY ENGINEER CITY ENGINEER DATE INSPECTOR KK /q I SHEET 12 OF 16 GENERALNOTES SEGMENTAL RETAINING WALL PRECAUTIONS 1. REFERENCED STANDARDS ASTM C1372 STANDARD SPECIFICATION FOR SEGMENTAL RETAINING WALL UNITS ASTM C140 SAMPLING AND TESTING CONCRETE MASONRY UNITS ASTM C145 SOLID LOAD BEARING CONCRETE MASONRY UNITS ASTM D1557 COMPACTION CHARACTERISTICS OF SOIL USING MODIFIED EFFORT ASTM D3034 PERFORATED PVC DRAINAGE PIPE ICC NO. ESR 2113 FOR KEYSTONE WALLS ASTM D2339 ASTM D3498 ASTM D572 2. MATERIAL DELIVERY, STORAGE, AND HANDLING CONTRACTOR SHALL CHECK MATERIALS UPON DELIVERY TO ASSURE THAT PROPER MATERIALS HAVE BEEN RECEIVED AND ARE NOT DAMAGED. CONTRACTOR SHALL PROTECT MATERIALS FROM DAMAGE DURING STORAGE AND HANDLING AND SHALL PREVENT CONTACT WITH MUD, WET CONCRETE, CHEMICALS, OR ADHESIVES. DAMAGED MATERIAL SHALL NOT BE INCORPORATED INTO THE RETAINING WALL STRUCTURE. 3. REQUIRED SUBMITTALS A. LIST OF ALL PRODUCTS PROPOSED FOR USE. B. PRODUCT SAMPLES. C. CURRENT MANUFACTURER'S MATERIAL AND INSTALLATION SPECIFICATIONS. 4. QUALITY CONTROL COMPACTION TESTING AND OBSERVATION DURING EARTHWORK OPERATIONS WILL BE PROVIDED BY THE PROJECT GEOTECHNICAL ENGINEER. 5. MASONRY WALL UNITS MASONRY WALL UNITS SHALL BE KEYSTONE UNITS: STANDARD III UNIT MEASURING 18"W X 18"D X 8"H. WALL UNITS SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM C1262, ASTM C1372 AND ASTM C140. WALL UNIT CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI AND SHALL HAVE A MAXIMUM MOISTURE ABSORPTION OF 6 TO 8%. 6. CONNECTING PINS WALL UNIT CONNECTING PINS SHALL BE Z' DIAMETER NON -CORROSIVE FIBERGLASS RODS WITH A MINIMUM FLEXURAL STRENGTH OF 128,000 PSI SHORT BEAM SHEAR OF 6,400 PSI. 7. CAP ADHESIVE CAP ADHESIVE SHALL BE SRW VOC RETAINING WALL AND PAVER ADHESIVE OR APPROVED EQUIVALENT CONFORMING TO ASTM D2339, ASTM D572 AND ASTM D3498. 8. LEVELING PAD LEVELING PAD MATERIAL SHALL BE 4' MINUS CRUSHED ROCK OR CRUSHED RECYCLED MATERIAL. 9. UNIT FILL UNIT DRAINAGE FILL SHALL CONSIST OF CLEAN 1" (25 MM) MINUS CRUSHED STONE OR CRUSHED GRAVEL MEETING THE FOLLOWING GRADATION TESTED IN ACCORDANCE WITH ASTM D-422: SIEVE SIZE PERCENT PASSING 1" (25 mm) 100 m 4" (19 mm) 75 - 100 No. 4 (4.75 mm) 0-10 No. 50 (300um) 0-5 00 10.A. REINFORCED BACKFILL 0 rn REINFORCED BACKFILL SHALL BE FREE OF DEBRIS AND MEET THE FOLLOWING GRADATION N TESTED IN ACCORDANCE WITH ASTM D-422: 0 0 SIEVE SIZE PERCENT PASSING r 2 inch (50 mm) 100 3/4-inch (19 mm) 100-75 No. 40 (425 um) 0-60 o No. 200 (75 um) 0-35 o PLASTICTY INDEX(PI) <20 and LIQUID LIMIT <40 per ASTM D-4318. c� 0 10.13. NO -FINES CONCRETE BACKFILL 0 CEMENT - PORTLAND CEMENT, TYPE I OR II PER ASTM C150 3 • AGGREGATE - NO. 57 OR NO. 8 STONE OR EQUIVALENT PER ASTM C33 _C! 0 AGGREGATE/CEMENT RATIO - APPROX. 6:1 BY WEIGHT c WATER/CEMENT RATIO - 0.35 TO 0.45 BY WEIGHT 0 IN -PLACE VOID RATIO - 20 - 30% • IN -PLACE UNIT WEIGHT = 110 TO 130 PCF • COMPRESSIVE STRENGTH - 2,000 PSI NOMINALLY @ 28 DAYS o THE ACTUAL "NO -FINES" CONCRETE MIX DESIGN WILL BE DETERMINED BY THE SUPPLIER a_ BASED ON LOCAL MATERIALS AND BATCHING EXPERIENCE. THE PROPER WATER/CEMENT o RATIO IS A FUNCTION OF COMPLETELY COATING ALL AGGREGATE IN THE MIXING PROCESS WHILE CREATING THE PROPER CONSISTENCY OF THE MATERIAL FOR PLACEMENT PURPOSES BY BEING NEITHER TOO WET OR TOO DRY. 0 11. GEOSYNTHETIC REINFORCEMENT (GSR) (IF REQUIRED) cn GSR SHALL BE POLYMER COATED WOVEN POLYESTER FABRICATED FOR EARTH o REINFORCEMENT. GSR SHALL BE TENSAR TPG60, TPG80, TPG130 & TPG205. i SUBSTITUTE EQUIVALENT GSRS SHALL BE APPROVED BY THE ENGINEER. A HIGHER STRENGTH GSR OF THE SAME MANUFACTURER MAY BE SUBSTITUTED WITHOUT o QUESTION. 12. DRAINPIPE c o DRAIN PIPE SHALL BE 4" PERF SDR 35 PVC OR TRIPLE WALL OR EQUAL DRAIN INSERTED INTO DRAIN -SLEEVE FILTERSOCK, ENCASED IN 1" MINUS CRUSHED ROCK. LOCATE DRAINS AS LOW AS POSSIBLE AND EITHER DAYLIGHT OR CONNECT TO SITE STORM DRAIN SYSTEM. 0 0 13. FILTER FABRIC m o FOR WALLS DESIGNED WITH STANDARD III UNITS, A MINIMUM 4.0 OUNCE FILTER FABRIC m GEOTEXTILE SEPARATOR (MIRAFI 140NC, TERRATEX N04.5 OR EQUIVALENT SHALL BE USED i TO CONTAIN THE DRAINAGE FILL WITHIN THE KEYSTONE UNIT ALLOWING PLACEMENT OF n SELECT BACKFILL FIRST FOLLOWED BY THE DRAINAGE FILL WITHIN THE UNITS. THIS 7) METHOD SHALL NOT BE USED WITH WALLS DESIGN WITH COMPAC II UNITS ONLY. U a L 0 U i c E o CHANGE NO. 0 i z T U 0 L v KEYSTONE RETAINING WALL PLAN EXECUTION 14. EXCAVATION CONTRACTOR SHALL EXCAVATE TO THE LINES AND GRADES SHOWN ON THE CONSTRUCTION DRAWINGS. CONTRACTOR SHALL BE CAREFUL NOT TO DISTURB EMBANKMENT MATERIALS BEYOND LINES SHOWN. 15. FOUNDATION SOIL PREPARATION EXCAVATED FOUNDATION SHALL BE OBSERVED AND APPROVED BY THE SOILS ENGINEER TO CONFIRM THAT THE ACTUAL FOUNDATION SOIL CONDITIONS ARE CONSISTENT WITH CONDITIONS ASSUMED FOR DESIGN AND IDENTIFIED IN THE REFERENCED GEOTECHNICAL REPORTS. UNACCEPTABLE FOUNDATION SOILS SHALL BE REMOVED AND REPLACED WITH APPROVED COMPACTED BACKFILL MATERIAL. FOUNDATION SOIL SHALL BE PROOF ROLLED PRIOR TO FILL AND GSR PLACEMENT. 16. LEVELING PAD INSTALLATION LEVELING PAD MATERIALS SHALL CONSIST OF WELL GRADED ROCK (4' MAX SIZE), 6" MIN THICKNESS ON COMPACTED ENGINEERED FILL. DIMENSIONS SHOWN ON CONSTRUCTION DRAWINGS. FINISHED LEVELING PAD SHALL HAVE A SMOOTH LEVEL SURFACE TO PROVIDE COMPLETE SUPPORT THE FIRST COURSE OF RETAINING WALL UNITS. 17. WALL UNIT INSTALLATION THE FIRST COURSE OF CONCRETE WALL UNITS SHALL BE CHECKED FOR LEVELNESS AND ALIGNMENT AND TO ENSURE THAT UNITS ARE IN FULL CONTACT WITH LEVELING PAD. UNITS SHALL BE PLACED SIDE BY SIDE FOR FULL LENGTH OF WALL. ALIGNMENT MAY BE ACCOMPLISHED BY MEANS OF A STRING LINE OR AN OFFSET FROM BASELINE. INSTALL FIBERGLASS CONNECTING PINS. CONTRACTOR MAY STACK KEYSTONE UNITS VERTICALLY IN ROWS BETWEEN GSR LAYERS, BUT NO MORE THAN 3 KEYSTONE UNITS BEFORE FILLING WITH UNIT FILL MATERIAL. FILL ALL VOIDS WITH UNIT FILL MATERIAL. SINCE THE UNIT FILL IS A DRAINAGE MATERIAL AND SELF COMPACTING, NO COMPACTION IS REQUIRED. SWEEP ALL EXCESS MATERIAL FROM TOP OF UNITS AND INSTALL NEXT COURSE(S). ENSURE WALL UNITS OF EACH COURSE ARE COMPLETELY FILLED WITH UNIT FILL MATERIAL AND THAT THE BACKFILL HAS BEEN PLACED AND COMPACTED PRIOR TO PROCEEDING TO NEXT COURSE(S). ENSURE THAT CONNECTING PINS PROTRUDE A MINIMUM OF 1" INTO NEXT COURSE. TWO PINS ARE REQUIRED PER UNIT. PULL UPPER UNIT FORWARD TOWARD THE WALL FACE, AGAINST PINS PROTRUDING FROM THE LOWER COURSE TO ACHIEVE CORRECT UNIT SETBACK SHOWN ON THE CONSTRUCTION DRAWINGS. WHERE THE WALL CHANGES ELEVATION, UNITS SHALL BE STEPPED WITH GRADE OR TURNED INTO THE EMBANKMENT WITH A CONVEX RETURN END. PROVIDE LEVELING PAD FOR UNITS IN AREA OF CONVEX RETURN END. EVERY COURSE OF WALL UNITS SHOULD BE CHECKED FOR LEVELNESS WITH MINOR SHIMMING DONE EVERY COURSE OR TWO, OR AS NEEDED TO INSURE THAT THE UNITS REMAIN TRUE TO DESIGN BATTER. SHIMMING MATERIAL SHOULD BE SOMEWHAT FLEXIBLE, SUCH AS 1/4" NYLON ROPE, TO COMPRESS SLIGHTLY AND DISTRIBUTE LOAD EVENLY WHILE AVOIDING HARD MATERIALS WHICH CAN CREATE LOAD CONCENTRATION POINTS. 18. CAP INSTALLATION CONSTRUCTION ADHESIVE SHALL BE USED TO PROVIDE PERMANENT CONNECTION OF CAPS TO WALL UNITS. APPLY ADHESIVE TO TOP SURFACE OF LOWER COURSE PRIOR TO PLACING CAP UNIT INTO POSITION. PLACE KEYSTONE CAP UNITS OVER CONNECTING PINS PROJECTING FROM UNITS BELOW. PULL FORWARD TO CORRECT SETBACK POSITION. BACKFILL AND COMPACT TO FINISH GRADE. 19. GSR INSTALLATION (IF REQUIRED) GSR SHALL BE PLACED AT THE LOCATIONS AND ELEVATIONS SHOWN ON THE CONSTRUCTION DRAWINGS OR AS DIRECTED BY THE ENGINEER. GSR SHALL BE ORIENTED WITH THE HIGH STRENGTH DIRECTION (ROLL DIRECTION) PERPENDICULAR TO THE RETAINING WALL ALIGNMENT. CORRECT ORIENTATION OF THE GSR SHALL BE VERIFIED BY THE CONTRACTOR. THE GSR SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL AND CONNECTED TO THE CONCRETE WALL UNITS BY HOOKING GSR OVER CONNECTING PINS. GSR SHALL BE PULLED TAUT AND ANCHORED WITH SOIL STAPLES OR NAILS 6' O.C. EACH WAY TO MAINTAIN TAUTNESS DURING BACKFILL AND COMPACTION. FOLLOW MANUFACTURER GUIDELINES REGARDING OVERLAP REQUIREMENTS. 20. BACKFILL PLACEMENT BACKFILL MATERIAL SHALL BE PLACED IN 8" - 12" LIFTS, AS COORDINATED WITH THE GEOTECHNICAL ENGINEER AND COMPACTED TO MINIMUM 90% OF MAXIMUM DRY DENSITY DETERMINED PER ASTM D1557. MOISTURE CONTENT OF BACKFILL SHOULD BE AT OR SLIGHTLY ABOVE OPTIMUM MOISTURE CONTENT. ONLY HAND -OPERATED COMPACTION EQUIPMENT SHALL BE ALLOWED WITHIN 3' OF THE FACE OF THE RETAINING WALL UNITS AND ANY NUCLEAR COMPACTION TESTING SHALL NOT BE PERFORMED WITHIN THIS ZONE WHERE INCONSISTENT RESULTS WILL OCCUR. BACKFILL SHALL BE PLACED FROM THE WALL REARWARD INTO THE EMBANKMENT TO ENSURE THAT THE GSR REMAINS TAUT. BACKFILL SHALL BE LEVEL SUCH THAT ANY SHALLOW DEPRESSIONS AND HUMPS DO NOT EXCEED 6" IN DEPTH OR HEIGHT. BACKFILL SHALL BE PLACED, SPREAD AND COMPACTED IN SUCH A MANNER TO MINIMIZE THE DEVELOPMENT OF SLACK OR LOSS OF PRE -TENSION OF THE GSR. TRACKED CONSTRUCTION EQUIPMENT SHALL NOT BE OPERATED DIRECTLY ON THE GSR. A MINIMUM UNCOMPACTED BACKFILL THICKNESS OF 6" IS REQUIRED PRIOR TO OPERATION OF TRACKED VEHICLES OVER THE GSR. TURNING OF TRACKED VEHICLES SHALL BE KEPT TO A MINIMUM TO PREVENT TRACKS FROM DISPLACING THE FILL AND DAMAGING THE GSR. RUBBER -TIRED EQUIPMENT MAY PASS OVER GSR REINFORCEMENT AT SLOW SPEEDS, LESS THAN 10 MPH. AVOID SUDDEN BRAKING AND SHARP TURNING. 20.A. NO -FINES CONCRETE BACKFILL PLACEMENT BACKFILL THE WALL WITH NO -FINES CONCRETE. ALL VOIDS INSIDE AND BETWEEN THE UNITS MUST ALSO BE FILLED. THE VERTICAL HEIGHT OF ANY POUR OF NO -FINES CONCRETE IS LIMITED TO 6 COURSES (4'). "NO -FINES" CONCRETE SPECIFICATION BOTANICAL GARDENS 230 QUAIL GARDENS DRIVE ENCINITAS, CALIFORNIA 92024 "NO FINES" CONCRETE IS A PERMEABLE CONCRETE MASS THAT IS MADE BY ELIMINATING THE FINE AGGREGATE COMPONENT IN CONCRETE WHICH CREATES A SIGNIFICANT VOID STRUCTURE WITHIN THE CONCRETE. THE MATERIAL IS PLACED IN A SEMI -LIQUID STATE AND ALLOWED TO HARDEN IN PLACE WITH MINIMAL COMPACTION AND PLACEMENT WORK AS REQUIRED TO LEVEL MATERIAL AND FILL ALL VOIDS. "NO FINES" CONCRETE SHALL CONSIST OF PORTLAND CEMENT, WATER AND 3/8" - 3/4" COARSE AGGREGATE. FLY ASH MAY ALSO BE USED AS PART OF THE MIX DESIGN AS REQUIRED. THE CONCRETE SHALL BE MIXED BY MACHINE AND THE QUANTITY OF WATER USED SHALL NOT EXCEED THAT REQUIRED TO COMPLETELY COAT ALL THE AGGREGATE PARTICLE WITHOUT FORMING EXCESSIVE GROUT. DESCRIPTION I APPROVED I DATE I BENCHMARK AS -BUILT I SIN 1 319121 FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 SCOPE OF WORK TWO KEYSTONE RETAINING WALLS RETAINING ON QUAIL GARDENS DRIVE IN THE CITY OF ENCINITAS, CALIFORNIA. WALL NO. LINEAR FEET SQUARE FEET 1 96 400 2 32 90 SPECIAL INSPECTION SHOULD BE PERFORMED BY THE ONSITE REPRESENTATIVE OF THE PROJECT'S GEOTECHNICAL FIRM STATEMENT OF SPECIAL INSPECTION (PER ESR-2113 SECTION 4.3) SPECIAL INSPECTION MUST BE PROVIDED IN ACCORDANCE WITH 2O15 AND 2012 IBC SECTIONS 1705.1.1, 1705.4 AND 1705.6 (2009 IBC SECTIONS 1704.15, 1704.5 AND 1704.7). THE INSPECTOR'S RESPONSIBILITIES INCLUDE VERIFYING THE FOLLOWING: 1. THE MODULAR CONCRETE UNIT DIMENSIONS. 2. KEYSTONE UNIT IDENTIFICATION COMPLIANCE WITH ASTM C1372, INCLUDING COMPRESSIVE STRENGTH AND WATER ABSORPTION, AS DESCRIBED IN SECTION 3.1 OF ESR-2113. 3. EXCAVATION FOR FOUNDATION, SUBGRADE CONDITION PRIOR TO LEVELING PAD PLACEMENT. 4. FOUNDATION PREPARATION: SOIL TYPE, CLASSIFICATION, SHEAR STRENGTH PARAMETERS AND COMPACTION FOR SUBGRADE. 5. OBSERVE PLACEMENT & SEATING OF GRAVEL LEVELING PAD. 6. KEYSTONE UNIT PLACEMENT, INCLUDING PLACEMENT OF ALIGNMENT PINS (SEE DRAWING, ACTUAL BATTER BY SURVEY OR CIVIL). 7. GEOSYNTHETIC REINFORCEMENT TYPE AND PLACEMENT. 8. BACKFILL PLACEMENT AND COMPACTION: SOIL TYPE, CLASSIFICATION, SHEAR STRENGTH PARAMETERS AND COMPACTION FOR BACKFILL. 9. COMPACTION OF BACKFILL TO 90% OF MAXIMUM DRY DENSITY PER ASTM D1557. 10. SOIL TYPE TO MEET MINIMUM DESIGN REQUIREMENTS. 11. DRAINAGE PROVISIONS, INCLUDING SUB -DRAIN PLACEMENT. 12. SPECIAL INSPECTION SHALL BE PERFORMED ON A CONTINUOUS BASIS. 13. PROVIDE REPORT AT THE COMPLETION OF WALL(S). DESIGN PARAMETERS FOR KEYSTONE WALL DESIGN: MINIMUM SOIL PROPERTIES: FOUNDATION SOIL: RETAINED SOIL: REINFORCED SOIL: (D = 320 cb = 320 fi = 32° y =120 PCF y =120 PCP y =120 PCP c=0PSF c=OPSF c=0PSF SEISMIC DESIGN: PGAM = 0.483g. SPECIAL INSPECTION REPORT PREPARED BY NINYO & MOORE DATED 01/08/2021 ON FILE WITH ENGINEERING DIVISION RECOMMENDATIONS: 9 • THE KEYSTONE WALLS SHALL BE CONSTRUCTED WITH FULL SPECIAL INSPECTION ACCORDING TO THE MANUFACTURERS SPECIFICATIONS AND RECOMMENDED PROCEDURES FOR INSTALLATION OF KEYSTONE BLOCKS, FIBERGLASS PINS, AND GSR REINFORCEMENT. • THE TEMPORARY EXCAVATION BACK -CUT, GRADING, GROUND IMPROVEMENTS, SUB -DRAIN, AND SURFACE DRAINAGE SYSTEM FOR THE KEYSTONE WALLS SHALL BE PER THE PROJECT SOILS AND CIVIL ENGINEER'S RECOMMENDATIONS. • SOILS ENGINEER SHALL REVIEW THE DESIGN PARAMETERS USED HEREIN FOR CONFORMANCE WITH THEIR RECOMMENDATIONS. • GLOBAL STABILITY HAS NOT BEEN ANALYZED BY OUR FIRM. IF NECESSARY, GLOBAL STABILITY SHOULD BE PERFORMED BY THE PROJECT SOILS ENGINEER AS RECOMMENDED IN SECTION 12.4 OF THE NCMA MANUAL. WALLS SHOULD NOT BE CONSTRUCTED WITHOUT THE APPROVAL OF THE PROJECT SOILS ENGINEER. • KEYSTONE RETAINING WALL WILL BE CERTIFIED BY EITHER THE ENGINEER OF WORK, GEOTECHNICAL ENGINEER OF RECORD OR THE SPECIAL INSPECTOR AS BEING CONSTRUCTED PER THE MANUFACTURER'S RECOMMENDATIONS PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES ON SITE, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. AS -BUILT APPROVALS LBLICWO�R DATE Stevel Nowak 3/9/21 CITY ENGINEER DATE PLANNING REVIEWER INSPECTOR QROFESS/ON9 �0����'� Z Z w No.33538 m Exp.6-30-2020 A CIVIL \�O��P OF CPS INT. DATE PLANS PREPARED UNDER SUPERVIS,10 OF NA DATE: L / NA .i..� R.C.E. NO.: 33538 JQo 3/q KK 1 3/q NICK SERVIN, P.E. EXP.: 6/30/20 STRUCTURAL REVIEW PERFORMED BY ESGIL, A SAFEBUILT COMPANY AS PLANCHECK 19-611 DATED MARCH 26, 2019 THE AREA BEHIND THE WALL CONTAINS GEOGRID REINFORCING MATERIAL (REINFORCED ZONE) THAT IS THE STRUCTURAL COMPONENT OF THE WALL SYSTEM. UNDER NO CIRCUMSTANCES ARE YOU TO EXCAVATE OR DRILL THROUGH, OR DAMAGE THE FABRIC IN ANY WAY. IF IT BECOMES NECESSARY TO DO SO, PLEASE CONSULT YOUR CIVIL AND/OR DESIGN ENGINEER TO EVALUATE THE STRUCTURAL IMPACT. THERE IS A SUB -DRAIN LINE AT THE BASE OF THE WALL. IT WILL BE STUBBED OUT FOR FINAL CONNECTION BY OTHERS. TO INSURE PROPER DRAINAGE, ENSURE THAT ALL CONNECTIONS ARE MADE IMMEDIATELY AFTER THE COMPLETION OF THE WALL. NO STANDING WATER SHOULD BE LEFT TO ACCUMULATE OR LEACH INTO THE REINFORCED ZONE ABOVE THE WALL. PADS OR SLOPES ABOVE THE WALL ARE TO DRAIN AWAY FROM THE WALL AND ANY REQUIRED 'V' DITCHES INSTALLED IMMEDIATELY AFTER WALL INSTALLATION IS COMPLETE. NO STANDING OR RUNNING WATER SHOULD BE ALLOWED TO FLOW NEAR THE SLOPE ADJACENT TO THE GRAVEL BASE.(BOTTOM) ANY KNOWN SUBTERRANEAN WATER SHOULD BE INTERCEPTED AND DIVERTED AWAY FROM REINFORCED ZONE AND BASE. ANY 'V' DITCH ABOVE THE WALL SHOULD BE DESIGNED OF SUFFICIENT SIZE TO REMOVE ALL SURFACE WATER AND AVOID THE FLOW OF WATER OVER THE TOP OF THE WALL. OVERFLOW CAN CAUSE EROSION AT THE BASE OF THE WALL THAT MAY UNDERMINE IT. ANY LANDSCAPE WATERING AND ADDITIONAL SURFACE DRAINAGE IN THE REINFORCED ZONE SHOULD BE DESIGNED IN CONJUNCTION WITH THE GEOTECHNICAL ENGINEER AND LIMIT WATER FROM PERCOLATING INTO THE REINFORCED ZONE, THIS SEGMENTAL WALL BLOCK IS CONSTRUCTED OVER A GRAVEL BASE. ALL SURFACE WATER RUN-OFF OR SLOPES MUST BE DIVERTED AWAY FROM THE BASE OF WALL TO PREVENT PONDING AND UNDERMINING THE BASE. ALL UTILITY LINE AND SANITARY CONSTRUCTION SHOULD BE AVOIDED WITHIN THE REINFORCED ZONE. ANY LINES CONSTRUCTED BEHIND THE GRID ZONE SHOULD BE COMPACTED TO 90%+. DO NOT OPERATE HEAVY EQUIPMENT WITHIN 3 FEET FROM THE TOP OF WALL. THE SURCHARGE FROM THE EQUIPMENT WEIGHT CAN PUSH THE WALL OUT, ANY REPAIRS ARE THE RESPONSIBILITY OF THE OWNER. ALL COMPACTED FILL MATERIAL WILL SETTLE OR CONSOLIDATE OVER TIME. SEGMENTAL WALLS REQUIRE COMPACTED FILL MATERIAL. ALL FOUNDATIONAL MATERIALS BELOW THE BLOCK AND GRID ZONE MUST BE TESTED PRIOR TO WALL CONSTRUCTION TO ENSURE PRIOR CONSOLIDATION AND COMPACTION OF THE FOUNDATIONAL MATERIALS. THERE IS AN ALLOWABLE VARIANCE OF +/- 6" IN THE WALL FACE DURING INSTALLATION AND THE SETTLEMENT PERIOD. SEGMENTAL RETAINING WALLS ARE FLEXIBLE (NOT RIGID AS ARE CMU WALLS). ALL STRUCTURES SUCH AS TRASH ENCLOSURES, PAVEMENT, CURBS, ETC., SHOULD BE DESIGNED TO HANDLE SOME GROUND MOVEMENT IF THEY ARE NEAR THE WALL, PLEASE CONSULT YOUR DESIGN ENGINEER FOR FURTHER DETAILS. PRIOR TO CONSTRUCTION A HARD COPY SHALL BE SIGNED AND LEFT WITH THE ONSITE HILLSIDE COMPANIES REPRESENTATIVE. REFERENCES KEYSTONE RETAINING WALL SYSTEMS, INC. 2011, KEYSTONE DESIGN MANUAL AND KEYWALL OPERATING GUIDE. KEYSTONE RETAINING WALL SYSTEMS, INC., KEYWALL, VERSION 3.7.2 BUILD 10, 2012. NATIONAL CONCRETE MASONRY ASSOCIATION, DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS, SECOND EDITION. 2016 CALIFORNIA BUILDING CODE, (CBC 2016) DELANE ENGINEERING, GRADING PLANS FOR SAN DIEGO BOTANICAL GARDENS, CAD FILE RECEIVED JANUARY 29, 2019. NINYO & MOORE, GEOTECHNICAL EVALUATION, SAN DIEGO BOTANIC GARDEN, 230 QUAIL GARDENS DRIVE, ENCINITAS, CA, PROJECT NO. 108112001, DATED MARCH 15, 2016. NINYO & MOORE, GEOTECHNICAL EVALUATION UPDATE, SAN DIEGO BOTANIC GARDEN IMPROVEMENTS PROJECT, 230 QUAIL GARDENS DRIVE, ENCINITAS, CA, PROJECT NO. 108685001, DATED NOVEMBER 14, 2018. ICC ICC ESR-2113: REPORT FOR KEYSTONE RETAINING WALL SYSTEMS, REVISED OCTOBER, 2017. NOTE: REFER TO GRADING PLANS PREPARED BY DELANE ENGINEERING FOR FINISHED GRADE ELEVATIONS AND WALL LOCATION. THE WALL BOTTOM ELEVATION IS BASED ON FINISHED GRADE ELEVATION PLUS EMBEDMENT REQUIRED FOR THE WALL ANY DISCREPANCY IN WALL ELEVATIONS SHOULD BE BROUGHT TO OUR ATTENTION. DRAWING INDEX SHEET z O U) z L1J W O w Q z Q CU LLI 3 O d. z w LLI LLI z_ z W i z III J Q U_ z 13 KEYSTONE WALL NOTES h 14 KEY MAP m LID 15 SECTION & DETAILS o 16 KEYSTONE WALLS 1 & 2 PROFILE DESCRIPTION ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT RECOMMENDED: AP P O GRADING PLAN FOR: SAN DIEGO BOTANIC GARDENS COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION JEs o E s EDWARD J. MMER 311 SAXONY LANE - APN 256-340-31-00 ��t� CITY NGI��( KEYSTONE WALL NOTES DATE DAT PLANNING CASE NO: 16-147 CDP LL z J CL J DRAWING NO. (� z_ 14094-G z SHEET 13 OF 16 W m CL od LO w O N 00 O I 1 I Place Additional Pieces of GSR When Angle Exceeds 20' Overlapping GSR Is Acceptable T �. •... Cap Unit Elevation 18" Cap Unit Plan 3-Plane Split Cap Unit Option * Dimensions & Availability Will Vary by Region GSR Installation on Curves NO SCALE Standard III Elevation Standard III Plan Backfill and Extended Over the Fiberglass Pins, Place Next Unit Pull GSR Taught and Backfill_ Stake as required. GSR & Pin Connection Dimensions May Vary by Region Block Types NO SCALE Proposed Building M CID to AE DO TW 229.00 0 N Keystone Cap Unit Cap Unit Secured with o Kapseal Adhesive or equal 0 I Near Vertical Batter Q Front Pin Alionment 3 a 18" Deep Unit Drainage Fill Extends to Filter Fabric behind Block for Entire Length & o Height of Wall. (3/4" Crushed Rock or Stone) —'— co See Drainage Detail C O I'llStandard III Unit FG 224.41 �- 3.33' E - .n in C (714 BW 223.00--- U) 4" Compacted Crushed Stone or Recycled Material Leveling Pad o l 6" Minimum Thickness m a " A 0 0 4 U o CHANGE NO. DESCRIPTION 0 AS -BUILT L 0 U may Tau outsiae oT connecting cores in aaamonal units above, if this occurs re -drill new pin holes as needed using a 5/8 inch masonry bit and realign units and/or use Keystone KapSeal adhesive (or approved equal) to secure units together. 3. GSR reinforcement is to be taut and anchored approx. 6' 0. C. ±2' each way with soil staples or nails. *NOTE: SUBDRAIN OUTLET ELEVATIONS AND LOCATIONS SHOULD BE VERIFIED BY AND COORDINATED WITH THE PROJECT'S CIVIL AND SOILS ENGINEERS. ANY STORM DRAIN SYSTEMS AND/OR TIE-IN LOCATIONS NEED TO BE DISCUSSED WITH HILLSIDE BEFORE WALL CONSTRUCTION. CONNECTION TO BE PERFORMED BY OTHERS. HILLSIDE COMPANIES IS NOT RESPONSIBLE FOR ANY DISCREPANCIES BETWEEN THE GRADING PLAN, FIELD CONDITIONS AND THESE SEGMENTAL RETAINING WALL PLANS. ANY DISCREPANCIES SHOULD BE BROUGHT TO HILLSIDE'S ATTENTION AS SOON AS POSSIBLE SO THAT A RESOLUTION CAN BE FOUND. ENGINEERING AND/OR CONSTRUCTION FEES MAY APPLY TO CHANGES DUE TO THESE DISCREPANCIES. DRAINAGE & UTILITIES IN THE GSR ZONE SOME UTILITY LATERALS AND DRAINAGE PIPES ARE ALLOWED IN THE GSR ZONE BUT MUST BE COORDINATED AND INSTALLED DURING CONSTRUCTION OF THE RETAINING WALLS. IF GSR IS ENCOUNTERED DURING ANY EXCAVATIONS, EXCAVATION MUST STOP IMMEDIATELY AND THE CONTRACTOR MUST BE CONSULTED TO MITIGATE AND/OR REPAIR ANY DAMAGE. WITH 8" CAP TOP OF DITCH IS POURED WITH A 4" MORTAR CAP ABOVE STANDARD UNIT. /1 THE UPPER MOST GSR REINFORCEMENT MAY BE CUT THROUGH DURING DITCH EXCAVATION Brow Ditch Section NO SCALE Q Unit C)o Drainage Q Fill Q - A geotextile separator shall be used Select to contain the drainage fill within the WITH 4" CAP TOP OF DITCH IS O Keystone unit allowing placement of POURED AGAINST STANDARD UNIT. Granular Backfill select backfill first followed by the Q ,�tt drainage fill within the units. This contained drainage zone limits the infiltration of fines into the wall Q Geotextile subdrain. Separator C) O la1Al�hlif�,1�_lh�UA_fjInl�f�l�f���l�l�l�lhltl�l�l�i�.1�11f��1���1h1�1�___. Reinforced Soil dD = 320 y = 120 pcf -- Tensar TPG60 7.0' Length --- Min. 4.0 oz Filter Fabric —•— Tensar TPG60 7.0' Length --- Compact to 90% Min. per ASTM D 1557 _ I I Foundation Soil = 320 y = 1201 pcf c = 0 srr r r I I=11 I I-1 I I - I ---—�-18" Deep Drainage Zone Drainage Detail C Unit Drainage Fill with Geotextile Separator NO SCALE 4" PERF SDR 35 PVC OR TRIPLE WALL DRAIN INSERTED INTO FILTER SOCK, ENCASED IN 4" CRUSHED ROCK BEHIND BLOCK. LOCATE DRAINS AS LOW AS POSSIBLE BUT OUTLET PIPES MUST BE ALLOWED TO DAYLIGHT UNLESS CONNECTING TO A STORM DRAIN SYSTEM. TYPICAL GEOSYNTHETIC REINFORCED SECTION (Wall 1 @ STA 10+31.50) 1" = 2' Typical Section for Case 1 (see profile for GSR length and locations) Standard III Units - Front Pins (See Sheet 16) QROFESS/, O S. ql 2 Z w No.33538 m cl-' Exp.6-30-2020 A j�xyTF CIVIL OF CPL Base Levelina Pad Notes: 1. The leveling pad is to be constructed of crushed stone 2-The base foundation is to be approved by the site geotechnical engineer prior to placement of the leveling pad. Excavation Limits Standard III Unit Width: 18" `Depth: 18" Height: 8" *Weight: 106 Ibs 6" Crushed Rock Leveling Pad Cap Unit Width: 181, *Depth: 10 1 /2" Height: 4" *Weight: 45 Ibs Standard III Unit/Base Pad Isometric Section View Dimensions & Weight May Vary by Region Recycled Materialy Step Leveling Pad (4" Minus) Note: IV V Jl�iiLC 1. The leveling pad is to be constructed of crushed stone. 2" x 5 4' Fiberglass Pins Front Face 24" Section Leveling Pad Detail NO SCALE TW 220. Keystone Cap Unit Cap Unit Secured with Kapseal Adhesive or equal `� APPROVED DATE BENCHMARK AS -BUILT APPROVALS UtJII�IVtIJ tlT: UKiiVVly tlY: l;titC KtU by: BW BW JP SRN 3 L9 21 INT. DATE PLANS PREPARED UNDER SUPERVI—JJ,ON OF FIELD SURVEY CONDUCTED BY COUNTY OF '� SAN DIEGO USING THE CONTINUOUSLY PUBLIC WORKS NA ---- DATE: L OPERATING REFERENCE STATION (CORS) DATE AND THE NGS GEOID MODEL 'GEOID09'. $tPvPi Nawa 3/9/21 DATUM' NAVD88 CITY ENGINEER DATE PLANNING N R.C.E. NO.: 33538 REVIEWER JQO 3/GI INSPECTOR KK 3/q NICKS RUIN, P.E. EXP.: 6/30/20 Near Vertical Batter Front Pin Alignment FG 218.55------\ 5.6T 3:1 Slope Max. Unit Face Foundation Soil Typical Planting Limits Section lit Unit BW 217.67,,,­/ i—III—II11— 4" Compacted Crushed 11=1 11=1 I I-1I—I 11=1 I I-� I I I Stone or Recycled Material ) II I IIIil1 Foundation Soil Leveling Pad I=III=_ (D = 320 6" Minimum Thickness .=1I I=III y =i2o pcf = c -' 0 sf I - roposed building Unit Drainage Fill (3/4" Crushed Rock or Stone) Min. 24" from Face of Wall Min. 4.0 oz Filter Fabric It N� 6.6.- W 0 Q Z H 0 W O 0' U Z W Z Z LI J t W W (Q V 4" PERF SDR 35 PVC OR TRIPLE WALL DRAIN INSERTED INTO FILTER --� SOCK, ENCASED IN 4" CRUSHED ROCK BEHIND BLOCK. LOCATE Q DRAINS AS LOW AS POSSIBLE BUT OUTLET PIPES MUST BE ALLOWED U TO DAYLIGHT UNLESS CONNECTING TO A STORM DRAIN SYSTEM. Z TYPICAL GRAVITY SECTION Wall 2 @ STA 10+04.50) 1"=2' Typical Section for Case 2 Standard III Units - Front Pins (See Sheet 16) ENGINEERING DIVISION APPROVALS RECO MENDED: APP VE JESS OWENS CDWARD J. V IMER CITY NGIN FI 11 _II9 49 DATE DAT CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT GRADING PLAN FOR: SAN DIEGO BOTANIC GARDENS _~ COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION 311 SAXONY LANE -APN 256-340-31-00 _ SECTIONS & DETAILS PLANNING CASE NO: 16-147 CDP m LID O LL Z Q J Q DRAWING NO. (D Z 14094-G z Q F— SHEET 15 OLIJ F 16 a N co �t7 O O) O 00 O O N N O N C O 0 C O O Q O� 3 v v d c rn 0 c W c 0 5_ LO O M CD 0 a c N m N O d 0 U_ �C 0 0 0 m Ln O N Plan Legend: Standard III Unit: GSR Location: U a 0 v E o CHANGE NO. 0 2 AS -BUILT Cr U 0 a� i 230 225 220 lea 10+00 a=� F `�'H�,eSiay let .N +cl.. `x t'Srirs-'S t i'y' W L; m._ T �,,dard I ! Units Front Pins 10+10 Top Grade: Tensar TPG60 Cap Unit: ��" DESCRIPTION 10+20 10+30 10+50 6 3 0 6 12 18 SCALE: 1 " = 6' APPROVED I DATE I BENCHMARK SIN 1 319121_1 FIELD SURVEY CONDUCTED BY COUNTY OF SAN DIEGO USING THE CONTINUOUSLY OPERATING REFERENCE STATION (CORS) AND THE NGS GEOID MODEL'GEOID09'. DATUM: NAVD88 1 AS -BUILT APPROVALS PUBLIC WORKS DATE Steve/Nowak 3/9/21 PLANNING REVIEWER CITY ENGINEER DATE INSPECTOR 1 :1 >f Wall 220 215 10+90 Wall 2 Eliminated Keystone Wall 2 Standard III Units Front Pin 10+00 2 10+10 Case 2 10+20 10+30 9Rpl ESS/paq S. sF F "Z �\G R22z ul ul No.33538 m * Exp.6-30-2020 * PLANVIEW PROVIDED AS A COURTESY BY DELANE ENGINEERING TO SHOW WALL ��qTF IL OF ALIGNMENT ONLY. PLEASE SEE ITS GRADING PLAN FOR DETAILED INFORMATION. INT. DATE PLANS PREPARED UNDER SUPERVIOF N ___ DATE: L �1 NA R.C.E. NO.: 33538 JQO 3/q ERVIN, P.E. KK /q EXP.:6/30/20 ENGINEERING DIVISION APPROVALS RECOMMENDED: APP OVER: JESS lb*)ENS WARD J. W MER ,I! 1 C IT � N DATE // I—� DATE •SAN i BOTANIC c • COUNTY OF SAN DIEGO DEPARTMENT OF PARKS AND RECREATION LANE i.. KEYSTONEPROFILE PLANNING NO:DP DRAWING NO. 1 -G I I.� SHEET 16 OF 16'