2020-14747 G LDEV-012506-2020 (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED 'UPDATED GEOTECHNICAL INVESTIGATION REPORT, PROPOSED MCMILLIN RESIDENCE, 1349 CREST DRIVE, ENCINITAS, CALIFORNIA" PREPARED BY CHRISTIAN WHEELER ENGINEERING DATED 1211612109 AND THE INFILTRATION STUDY TITLED 'PRELIMINARY STORM WATER INFILTRATION FEASIBILITY STUDY, PROPOSED MCMILLIN RESIDENCE, 1349 CREST DRIVE, ENCINITAS, CALIFORNIA'; PREPARED BY CHRISTIAN WHEELER ENGINEERING DATED 711312020 ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. �;li��►�I��;Iu'i�'1•'�C�1►��'�GIi�:1�i1:iCl�i►�I��l;�i1:ILL�i'Li1�'i�� ' I'i(►�L 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. B. GRADING AND EQUIPMENT OPERATING WITHIN ONE-HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5'30 P.M. AND 730 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE -CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR. CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE -CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633-2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND/OR FINAL RELEASE OF SECURITY, AN 'AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT NO. 14747-G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS -GRADED PLAN". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT-OF-WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONT06ICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT, DIRECT OR TEMPORARILY HALT GROUND -DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIVITIES ARE ALLOWED TO RESUME. 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.$ IF HUMAN REMAINS ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONERS OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTURBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED ARCHAEOLOGIST AND/OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THE CORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097.98. IF SUCH A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTECTED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND/OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW. AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU (IN PLACE), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT ANDY MCMILLIN AT (858) 245-8812, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP/IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND/OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP/IMP FACILITY AND/OR THE TURF/LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP/BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP/8MP. 6. ALL STORMWATER IMP/BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. B. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON-COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OILI GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY -APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK. - A. SEWERS - DEH - (858) 505-6700 B. GAS & ELECTRIC - SDGE - (760)-438-6200 C. WATER - SAN DIEGUITO WATER DISTRICT 1-800-227-2600 D. TELEPHONE - SBC BELL - (760)-489-3411 E. CABLE TV - COX COMMUNICATIONS-(760)-806-9809 X-2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE (760)-633-2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633-2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. FIRE NOTES. 1. ALL ROADWAYS SHALL BE A MINIMUM OF 24 FEET IN WIDTH DURING CONSTRUCTION AND MAINTAINED FREE AND CLEAR, INCLUDING THE PARKING OF VEHICLES, IN ACCORDANCE WITH THE CALIFORNIA FIRE AND THE ENCINITAS FIRE DEPARTMENT. 2. ALL FIRE DEPARTMENT CONNECTIONS SHALL BE MOUNTED AT THE FOLLOWING HEIGHT(S): 36 TO 42 INCHES ABOVE FINISHED GRADE, TO THE TOP OF THE CONNECTION. A. IF AN FDC IS INSTALLED SEPARATE FROM THE BACKFLOW/DOUBLE DETECTOR CHECK, IT SHALL BE LOCATED A MINIMUM OF 5 FEET FROM THE BACKFLOW/DDC VALVE. B. WHEN AN FDC IS ATTACHED TO THE BACKFLOW/DDC THE FDC MOUNTING HEIGHT SHALL STILL BE 36 TO 42 INCHES MAX ABOVE FINISHED GRADE. C. IF THE BACKFLOW/DDC IS INSTALLED WITHOUT AN VDC, BOTH OS&Y VALVE HANDLES SHALL BE MOUNTED 36 TO 42 INCHES ABOVE FINISHED GRADE. D. BUSHES, TREES, AND SIMILAR FOLIAGE SHALL NOT BE LOCATED WITHIN A RADIUS OF 5 FEET OF THE FDC OR BACKFLOW/DDC VALVE ASSEMBLY. GROUND COVER LANDSCAPE IS ACCEPTABLE. E. TOP OF STEM FOR BACKFLOW/DDC SHALL NOT EXCEED 48 INCHES IN HEIGHT. 3. PRIOR TO THE DELIVERY OF COMBUSTIBLE BUILDING CONSTRUCTION MATERIALS TO THE PROJECT SITE ALL OF THE FOLLOWING CONDITIONS SHALL BE COMPLETED TO THE SATISFACTION OF THE FIRE DEPARTMENT. - A. ALL WET AND DRY UTILITIES SHALL BE INSTALLED AND APPROVED BY THE APPROPRIATE INSPECTING DEPARTMENT OR AGENCY, B. AS A MINIMUM, THE FIRST LIFT OF ASPHALT PAVING SHALL BE IN PLACE TO PROVIDE A PERMANENT ALL-WEATHER SURFACE FOR EMERGENCY VEHICLES: AND C. ALL FIRE HYDRANTS SHALL BE INSTALLED, IN SERVE AND ACCEPTED BY THE FIRE DEPARTMENT AND APPLICABLE WATER DISTRICT. EARTHWORK DATA II GEPAMVBT OF STEEPEST EXISTING NATURAL SLOPE ON -SITE = _N/A MAXIMUM VERTICAL DEPTH OF CUT = 4.5' MAXIMUM VERTICAL DEPTH OF FILL = 3.7' CUT = 1.250 C.Y. FILL = 880 C.Y. EXPORT= 370 C.Y. REMEDIAL = 850 C.Y. STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRICTION STTF ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. ��Ii1�iILPI iliiil �LI ��Zelell�i1►�IeLTiiliPiilil��lel�l�i),^I�Ir1�I►ICii►�1e7.^I�1;'I�i1.9�:i DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY, THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST- GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. L^Li7�ei►.GYTe1��i1:1�II��TiliP►iil�l�y:L1�:1��ii►�iiuiTa��a rI I I I I l.Q�ii�.rl.��il rritl.��r_riair_►��n.lr�la STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING TORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNERS) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE WOOD AND CLEARED VEGETATION CAN BE RECYCLED. NON -RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STOPMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMORAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633-2770. HEU.TM IMPERVIOUS AREA AREA DISTURBED. =40,382 SF TOTAL EXISTING ON -SITE IMPERVIOUS AREA: = 51867 SF TOTAL NEW ON -SITE IMPERVIOUS AREA: =14,527 SF TOTAL EXISTING ON -SITE IMPERVIOUS AREA TO REMAIN.' = 1,938 SF TOTAL NET INCREASE IN ON -SITE IMPERVIOUS AREA: =10,598 SF SHEET INDEX 1 TITLE SHEET 2 NOTES, SECTIONS & DETAILS 3 GRADING PLAN 4 EROSION CONTROL 5 STRUCTURAL WALL NOTES & DETAILS PUBLIC WORKS PLANNING DIVISION ANDREW S. MCMILLIN & TARA MCMILLIN TRUSTEES OF THE ANDREW & TARA MCMILLIN LIVING TRUST P.O. BOX 21010 EL CAJON, CA 92021 (858) 245-8812 SITE ADDRESS 1349 CREST DRIVE ENCINITAS, CA 92024 APN.262-012-11 LEGAL DESCRIPTION REAL PROPERTY IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: THE WESTERLY 278.03 FEET OF LOT 7 IN BLOCK 'E" OF PALOMARES HEIGHTS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 2114, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 19, 1928. SITE VICINITY MAP OWNER'S CERTIFICATE NOT TO SCALE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK ORCONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. . �V vvN SIGNATURE. DATE: IIO 20 ANDREW MCMILLIN ANDREW AND TARA MCMILLIN LIVING TRUST v ` clV SIGNATURE: DATE: II/30120 TARA MCMILLIN ANDREW AND TARA MCMILLIN LIVING TRUST SOILS ENGINEERS CERTIFICATE I, DANIEL ADLER A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 5122118. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. Qp,OFESSI(01-) p O l 10115120 8. L 4 Z � DANIEL B. ADLER DATE RCE 36037 ti EXP. DATE: 06130122 CD No. 36037 Exp. 06/30/22 CHRISTIAN WHEELER ENGINEERING S'T CIVIL 3980 HOME AVENUE q OF SAN DIEGO CA 92105 CA (619) 550-1700 JOB #: 2190113.01 STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE ORPROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. SIGNATURE: r' DATE: 11/23/2020 BRIAN ARDOLINO QppFESSIpN PASCO LARET SUITER & ASSOCIATES 535 N. HIGHWAY 101 SUITE A Z q SOLANA BEACH, CA 92075cp (858) 259-8212 ,`�" ti� �� z RCE EXPIRES: 12-31-21 CM w o No. 71651 o rn m Exp. 12/31/21 PASCO LARET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 North Highway 101, Ste A, Solana Beach, CA 92075 ph 858.259.8212 � fx 858.259.4812 1 plsaengineering.com PARKS AND RECREATION BMP PROJECT STATUS PRIORITY STORMWATER TREATMENT FACILITIES TO BE MAINTAINED BY HOMEOWNER IN ACCORDANCE WITH 'MAINTENANCE AGREEMENT FOR PRIVATE STORMWATER TREATMENT AND STORMWATER POLLUTION CONTROL FACILITIES" RECORDED ON ------------ AS DOC. # SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT n Annette Saul 12/9/20 12/D7/2020 "2I1I2p�a SIGN DATE SIGN DATE SIGN DATE SIGN DATE SIGN DATE CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS UCJ DT: V UI IHTRG ' LI1ClRA or: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. I'RG DESCRIPTION.' STATION 'ENC 39" LOCATION.' 2.5" BRASS DISC By TOP OF CURB M,w DF�THE MIDGE NT OF OF IETUiV OR & LAKE RECORD FROM: ROS IB416 ELEVATION: 323.983 DATUM: NAVD88 INT. DATE PLANS PREPARED UNDER SUPERVISION OF /1 _ DATE: II/23/2020 r\. //��►�ll-- R.C.E. NO.: 71651 BRIAN MICHAEL ARDOLINO 12-31-21 EXP.: RECOMMENDED. APPROVED. Ste�ve� Nawa ly ��,��C . ?.d;�,ry,, � STEVEN NOWAK EDWARD J. WIMMER DATE 12/10/2020 DATE !2llO12020 GRADING PLAN FOR: 1349 CREST DRIVE ANDREW & TARA MCMILLIN LIVING TRUST APN: 262-012-11 PLANNING CASE NO. CDP-003420-2019 14747'G LDEV-012506-2020 PUBLIC S BRIAN M. ARDOLINO DATE FLAMBE REV�R SENIOR ENGINEER DATE INSPECTOR SHEET 1 OF 5 w H U Q 0 u) co Ca CCn N 0 worn :U co w�Qrn �HWO) Q=mm Q� Cj Zz Co LLB J LLB �cn cnC)!�! PLSA 3088 F 11/30/2020 kinrC0. SAN DIEGUITO WATER DISTRICT NOTES 1. THE MAINTENANCE OF ALL PROPOSED BMP S WILL BE THE RESPONSIBILITY OF THE OWNERS. THIS WILL INCLUDE ANY POST -CONSTRUCTION BMP AS WELL AS ANY CONSTRUCTION BMP THAT IS DETERMINED TO NEED TO REMAIN PERMANENTLY OR FOR A SPECIFIED PERIOD OF TIME AFTER THE COMPLETION OF ALL CONSTRUCTION OPERATIONS. 2. THE OWNER WILL BE PRESENTED WITH INFORMATION ON SOURCE CONTROL MEASURES, SUCH AS THE PROPER MEANS OF DISPOSING OF POLLUTANTS, DIRECTING WAS WATER INTO LANDSCAPING AREAS RATHER THAN INTO THE STREET GUTTER OR STORM DRAIN, MINIMIZING THE USE OF HOUSEHOLD CLEANERS AND OTHER PRODUCTS WHEN THEY HAVE THE POTENTIAL TO CONTRIBUTE POLLUTANTS INTO STORM WATER, AND SPILL CLEAN UP TECHNIQUES. 3. IN THE EVENT THAT LANDSCAPING MATERIALS ARE REQUIRED TO BE STOCK- PILED, THE STOCKPILES WILL BE LOCATED OUTSIDE OF ANY DRAINAGE COURSE IN ORDER TO REDUCE THE POTENTIAL FOR STORM WATER TO COME IN CONTACT WITH AND SUSPEND THE MATERIALS WITHIN ITS FLOW. IN ADDITION TO THE LOCATION OF THE STOCKPILES, WHEN THE STOCKPILES WILL REMAIN IN PLACE FOR THE COURSE OF MORE THAN 1 DAY, THEN THE STOCKPILE WILL BE ADEQUATELY COVERED SUCH THAT PRECIPITATION WILL NOT BE CAPABLE OF COMING IN CONTACT WITH THE STOCKPILED MATERIAL. 4. THE PROPOSED IRRIGATION SYSTEM WILL HAVE AN AUTOMATED RAIN SHUTOFF DEVICE, WHICH WILL DISCONTINUE IRRIGATION IN THE EVENT OF RAIN AND IF THE SOIL IS SUFFICIENTLY SATURATED. 5. THE PROPOSED IRRIGATION SYSTEM WILL BE ROUTINELY INSPECTED AND MAINTAINED TO ENSURE THAT OVER WATERING IS MINIMIZED, BROKEN OR MALFUNCTIONING SPRINKLER HEADS WILL BE REPLACED AS NEEDED, AND IN THE EVENT THAT ANY IRRIGATION PIPING DEVELOPS CRACKS, LEAKS OR BREAKS REPAIRS WILL BE ARRANGED FOR AND THE IRRIGATION SYSTEM WILL EITHER BE SHUT -DOWN ENTIRELY OR THE PROBLEM AREA WILL BE ISOLATED AND TAKEN OFFLINE. IF POSSIBLE, UNTIL THE PROBLEM IS CORRECTED. 6. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 7. OWNER TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN AN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBLIBITY OF THE OWNER TO KNOW WHERE THE LOCATION OF THE PROPERTY LINE IS. B. ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. 9. NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. 10. EROSION CONTOL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, GRAVEL BAGS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE. MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS, PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE.) 11. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (DCIA) SHALL BE ALLOWED. DCIA MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS, SUCH AS ROOF, ROOF DRAIN, DRIVEWAY, AND STREET. BMP MEASURES SHALL BE IDENTIFIED ON THE SITE PLAN. MOST COMMON MEASURES ARE DESIGNATED TURF AREAS, WHICH RECEIVE ROOF DRAINS AND RUNOFF FROM IMPERVIOUS AREAS. TURF AND LANDSCAPED AREAS THAT ARE DESIGNED FOR BMP S SHALL BE DELINEATED ON PLANS AND A NOTE PLACED ON PLANS PROHIBITING MODIFICATION OR REMOVAL OF THE BMP LANDSCAPE AREAS WITHOUT A CITY PERMIT. ROOF DRAIN NOTE • FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND/OR INTO THE PUBLIC STORM DRAIN SYSTEM. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. GRADING NOTE: ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPLICANTS PROPERTY. IF ANY DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORK OR AT THE DISCRETION OF THE CITY FIELD INSPECTOR. A WRITTEN LETTER OF PERMISSSION FROM THE ADJACENT PROPRTY OWNER MUST BE OBTAINED AND SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ADJACENT PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AND SUBMITTED TO THE CITY IS GROUNDS FOR A STOP -WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION IS OBTAINED. EXISTING EASEMENTS EASEMENTS PER TITLE REPORT DATED 0710712020 BY FIRST AMERICAN TITLE CO.: 03 AN EASEMENT FOR RIGHT OF WAY AND INCIDENTAL PURPOSES TO SDG&E IN THE DOCUMENT RECORDED 12/15/43 AS BOOK 1604, PAGE 114 OF O.R. THE LOCATION 9 WIDTH OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. ® AN EASEMENT FOR RIGHT OF WAY FOR DRIVEWAY PURPOSES AND INCIDENTAL PURPOSES IN THE DOCUMENT RECORDED 9130147 AS BOOK 2493, PAGE 277 OF O.R. AN EASEMENT FOR PUBLIC RIGHT OF WAY EASEMENT AND INCIDENTAL PURPOSES IN THE DOCUMENT RECORDED 4/01/0B AS INSTRUMENT NO. 08-169415 OF O.R. DEVELOPMENT NOTES. 1. ALL EXISTING STRUCTURES ON SITE ARE TO BE DEMOLISHED UNLESS NOTED OTHERWISE. 2. EXISTING UTILITIES SHOWN PER BEST AVAILABLE RECORDS. ACTUAL FIELD CONDITIONS MAY VARY 3. ALL EXISTING OVERHEAD ONSITE UTILITIES TO BE UNDERGROUNDED. 4. ALL UNDOCUMENTED AND/OR UNSUITABLE FILL MATERIALS ACROSS THE ENTIRE PROJECT SITE SHALL BE REMOVED AND REPLACED TO THE SATISFACTION OF THE PROJECT SOILS ENGINEER AND CITY ENGINEER. 5. THE DEVELOPEMENT PROPOSES TO DISTURB APPROX. 40,382 SF OR 0.93 AC. 6. THE DEVELOPMENT PROPOSES TO UTILIZE A SEPTIC SYSTEM. 7. PER THE PROJECT GEOTECHNICAL REPORT, EXTERIOR CONCRETE SLABS ON GRADE SHALL HAVE A MINIMUM THICKNESS OF 5 INCHES AND BE REINFORCED WITH AT LEAST NO. 4 BARS PLACED AT 18 INCHES ON CENTER EACH WAY (OCEW). DRIVEWAY SLABS ABUTTING LANDSCAPE AREAS SHOULD BE PROVIDED WITH A THICKENED EDGE AT LEAST 12 INCHES DEEP AND 6 INCHES WIDE. SEE PROJECT GEOTECHNICAL REPORT FOR MORE RECOMMENDATIONS. 1. WATER MAIN, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON-EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND/OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5-FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6. MINIMUM HORIZONTAL SEPARATION OF 10-FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. B. CALIFORNIA STATE LAW ASSEMBLY BILL AB-1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECT JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC-17 OR WC-18. MONUMENT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND/OR BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BY A LICENSED LAND SURVEYOR OR A REGISTERED CIVIL ENGINEER AUTHORIZED TO PRACTICE LAND SURVEYING. A CORNER RECORD OR RECORD OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE LICENSED LAND SURVEYOR OR THE REGISTERED CIVIL ENGINEER AS REQUIRED BY THE LAND SURVEYORS ACT INSPECTION NOTE.' SPECIAL INSPECTION OF ALL POST CONTRUCTION BMP PLANTERS, CLEANOUTS, ETC. BY THE ENGINEER OF RECORD OR ANOTHER LICENSED CIVIL ENGINEER REQUIRED AT THE FOLLOWING STAGES. PROGRESS PICTURES OF BMP PLANTERS, CLE4NOUTS, ETC. CONSTRUCTION SHALL BE TAKEN & PROVIDED TO THE CITY AT THE FOLLOWING STAGES: 1. PLANTER BMP WALL INSTALLATIONS 2. PLACEMENT OF PERFORATED PIPE$ RISER PIPES, OUTLET PIPES ETC. 3. PLACEMENT OF GRAVEL LAYERS 4. PLACEMENT OF ENGINEERED SOIL LAYERS 5. FINAL COMPLETED BASIN WITH VEGETATION ESTABLISHED SEE SPECIAL INPSECTION REPORT PREPARED BY PASCO LARET SUITER & ASSOCIATES DATED ON FILE WITH ENGINEERING DIVISION m APN 262-012-08 0 GAP/JOINT FILLER* 10' MAX ' 17. d .... 1%MIN e��e��e���-:tee•® 18 " ENGINEERED- * SEE NOT BEL II I IMPERMEABLE LINER ON SIDS DAILl�TO DEEP-ROOTED DROUGHT TOLERANT PLANTS FOR WELL -DRAINED SOILS OR CITY APPROVED EQUIV. 1 12"X12" BROOKS BOX OVERFLOW INLET TG 385.6 TW 366.3 II \I I/ III II 4 IR OVERFLOW �o" uTAI WEIR IE 385.96 2 X1.5' GRAVEL SPREADER SATISFACTION OF GEDTECHNICAL ENG 6" OF 3/8" GRAV�- 12" OF 3/4" GRAY ** SEE NOTE BELO I 1=III- 4"p VAC 4" PERFORATED PIPE -FLOW ORIFICE DRILLED 3" MIN AGGREGATE BELOW UNDERDRAIN INTO RESrRICTOR PLATE. PERF. PIPE NETWORK TO HAVE ONLY 1 POINT OF CONNECTION TO A BOX VIA ORIFICE 5" THICK CONCRETE PA W/ N0. 4 BARS PLACED 18" OCEW YR ROCK PER GEOTECH RECOMMENDATIONS' GER *GAP/JOINT BETWEEN PAVERS SHALL BE A MINIMUM OF 5% OF THE PAVER DIMENSION. A JOINT SHALL BE INSTALLED AT THE OUTER BOUNDARY OF THE PAVER. ALL JOINTS TO BE FILLED WITH 3/8" OR LARGER CRUSHED ROCK OR GRAVEL. NOTE.' SEE CUT-OFF WALL & STABILIZATION FABRIC PER GEOTECHNICAL ENGINEER RECOMMENDATIONS CUSTOM PERVIOUS PAVER DRIVEWAY DETAIL NTS * BIORETENTION 'ENGINEERED SOIL" LAYER SHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 65% SAND, 15% COMPOST OR HARDWOORD MULCH, AND 20% TOPSOIL, FREE OF STONES, STUMPS; ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. ** 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL BIORETENTION AREA DETAIL NTS HOLD HARMLESS FOR DRAINAGE AGREEMENT RECORDED APRIL 1, 2020 AS DOCUMENT 2008-169414 OF O.R. ENCROACHMENT MAINTENANCE 6 REMOVAL AGREEMEN' RECORDED 1 2020 AS DOCUMENT 2020- ____________- OF O.R. NTS GAP/JOINT FILLER* 10' MAX Q 4" THICK CONCRETE PA W/ NO. 3 BARS PLACED 18" 0 �1= 6" MIN CRUSHED ROCK PER GEOTECH RECOMMENDATI III -III- 3/4" OR LARGER *GAP/JOINT BETWEEN PAVERS SHALL BE A MINIMUM OF 5% OF THE PAVER DIMENSION. A JOINT SHALL BE INSTALLED AT THE OUTER BOUNDARY OF THE PAVER. ALL JOINTS TO BE FILLED WITH 3/8" OR LARGER CRUSHED ROCK OR GRAVEL. NOTE SEE CUT-OFF WALL & STABILIZATION FABRIC PER GEOTECHNICAL ENGINEER RECOMMENDATIONS CUSTOM PERVIOUS PAVER PATIO DETAIL NTS PL I APN 262-012-10 ORIFICE PLATE.' MIN SQUARE DIMENSIONS 1.0 FT GREATER MIN. 6" THAN PIPE DIA. HOT DIP (TYP.) STAINLESS STEEL 1/4" GALVANIZED PLATE AFTER BOLT OR APPROVED EAUAL HOLES HAVE BEEN DRILLED INFLOW PIPE (4" • PERF. PVC TYP.) N LOW -FLOW ORIFICE y y (SIZE PER PLAN) NOTE ORIFICE AND FLANGE -TCL 3/8" DIA. CONNECTION TO CONCRETE F- HOLE (TAP.) SHALL BE FILLED WITH 30 DUROMETER NEOPRENE RING FLOW CONTROL ORIFICE PLATE DETAIL NTS BUBBLER ip' MIN ' i5' MAX - - <-3 O -tS-O O O Off, 2' -cS- O O 0�0_-� -r 0cT�ZS00�0�0__� - v- O O 0�O--�'-- O_ O___o-- rs 4" PERFORATED COBBLE STORMORAIN PIPE RIP -RAP IE 381.3 SPREADER COBBLE RIP -RAP SPREADER DETAIL NTS PL EX. ACCESS EASEMENT 10' ENCE PER APN OTHERS i 262-012-12 - Z F%T IT -I � Irt -IIII EX. AC DWY �i on�rl �cn TO REMAIN LEGEND SUBDIVISION BOUNDARY ADJACENT PROPERTY LINE PROPOSED SETBACKS CENTERLINE OF RIGHT-OF-WAY EXISTING EASEMENT EXISTING SPOT ELEVATION EXISTING CONTOUR EXISTING WATER MAIN EXISTING SEWER MAIN PROPOSED TOP AND BOTTOM OF RETAINING WALL ONLY PROPOSED SPOT ELEVATION PROPOSED CONTOUR PROPOSED BUILDING FOOTPRINT 4" PVC DRAINAGE PIPE 6" PVC DRAINAGE PIPE 8" PVC DRAINAGE PIPE DRAINAGE DIRECTION DRAINAGE SWALE (1% MIN) RETAINING WALL PER STRUCTURAL LIMIT OF GRADING LIMIT OF PAD PCC PAVING PERVIOUS PAVER PER OTHERS BIORETENTION BASIN SITE WALL PER OTHERS k100.0 S TW@FG 102.0 BW@ FG l00.0 FS 100.0 AB AGGREGATE BASE AC ASPHALT CONCRETE APPROX APPROXIMATE BCR BEGIN CURB RETURN BW@FG BOTTOM OF WALL AT FINISH GRADE CL CENTER LINE DW DOMESTIC WATER ECR END CURB RETURN EE EMBEDMENT ELEVATION EL ELEVATION EX EXISTING FS FINISH SURFACE FG FINISH GROUND FYSB FRONT YARD SETBACK FL FLOWLINE HP HIGH POINT IE INVERT ELEVATION LF LINEAR FEET MAX MAXIMUM MIN MINIMUM OCEW ON CENTER EACH WAY PL PROPERTY LINE PROP PROPOSED PUB PUBLIC PVT PRIVATE RIM RIM ELEVATION RYSB REAR YARD SETBACK SO STORM DRAIN SDRSD SAN DIEGO REGIONAL STANDARD DRAWING SF SQUARE FEET SS SANITARY SEWER SYSB SIDE YARD SETBACK TC TOP OF CURB TF TOP OF FOOTING TG TOP OF GRATE TW TOP OF WALL TW@FG TOP OF WALL AT FINISH GRADE TYP TYPICAL I\IV WALL PER STRUCTURAL SEE SHEET 5 CIO No. 71651 Exp. 12/31/21 PASCO URET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 I\Torth Highway 101, Ste A, Solana Beach, CA 92075 ph 858.259.8212 0 fa 858.259.4812 1 plsaengineering.com CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS UCJ DT: UI IHT DT: LI1ClRCU DT: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. I'RG DESCRIPTION.' STATION 'ENC 39" LOCATION: 2.5" BRASS DIX IN TOP aF CUB NW QUADRANT OF BIRIVECHAM OR & LAKE DR IN THE MIDDLE OF RETURN RECORD FROM: ROS 18416 ELEVATION: 323.983 DATUM: NAVD88 INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: II/23/2020 r\, - R.C.E. NO.: 71651 k OC. BRIAN MICHAEL ARDOLINO 12-31-21 EXP.: RECOMMENDED: APPROVED: Steve/ Nowak. d . wl� STEVEN NOWAK EDWARD J. WIMMER DATE 12/10/2020 DATE !2llO, 00Z0 GRADING PLAN FOR: 1349 CREST DRIVE ANDREW & TARA MCMILLIN LIVING TRUST APN: 262-012-11 PLANNING CASE NO. CDP-003420-2019 14747-G LDEV-012506-2020 PUBLIC WOWS BRIAN M. ARDOLINO DATE FLAMBE REV�R SENIOR ENGINEER DATE INSPECTOR SHEET 2 OF 5 PLSA 3088 F ii/30/2020 T / PRO EX. PARADISE PA t E T TREE IN -PLACE. E rm CT PROTECTIVE TP / ING PER ARBORISf E PROTECT EX. CANARY I ATE PALM CITY STREET IN -PLACE. ERECT PROTE TPZ FENCING PER AFE A APPROX. LOCATIO EX. 12" ACP WATER 3 j I \ 1 REMOVE EX. -� 1 DRIVEWAY I \ m I I \ \ EX. 518" WATER METER. DISTRICT TO UPSIZE TO 1" WATER SERVICE & DUAL METER PER WAS WS-09 & WC-17 AT OWNERS EXPENSEI I / I JW 1 > I fr 1 W I w I � w I FECT' EX. CANARY ISLAND-= PALM CITY STREET TREE LACE. ERECT PROTECTIVE( FENCING PER AR30RIS (EX 395.6) I a a LL 0 ww �0 0 w (Ex;-7) , 26.3 t \ 3 EX. \WATER 9 GAS II PROTECT IN I I � ...........A 1 I I COMM. POLE FD I IP & DYSC BIRD OF PARADISE I WIND BREAK \ 12" PVC SO CO 6" PVC SD BYPASS IE 383.6 LS ?�318 \ \ \ B I - I r �'1�1' - RIM 388.3 @ 2% MIN - - " TW � E E E E E FENCE PER = E 386.4 i87c6 PCCE MG 384.6 E - C 1( 1 I OTHERS-'-'73`�978:� - /- E/ / �� - -.E /- /- - - - TC_ - - ------------------------------------------ ---- - - --------------------------------- - =- EE E 3 9 J I _ ,--- =_E ==-----_�-,- E -- --- --- - - - - - - - - ------IS, --- ---- - - - - ---- ---- - - _ _ _ _-- _ --- -- --- 6" PVG SD BYPASS J _ _ _ - _ TG 3932 @ 2% MHV\ - - - -- ----- - _ _ _ ________ _ - - I FS �893' '\. J / ovERHEAD �LEC. 1) RANS EDGE TW@FG 385.9 / OVERFLOW WEIRS IE 3908 ------ - - - ------ - - - - i, // ` Q' I � PAD (T11P) BW@FG 365.6 / EVERY 1S ALONG --- _____----- S T SMALy _ITR . E� &BRUSH TG 3062 I TG 386.0 / GRAVEL SPREADER � / I IE 3852 6" PVC SD TG 386.0 I 384 8 / IE 385.96 393.7 391.7 j ' - J T RTHEN SW 2' mn - 394134 F I W � ml CD - of ti Z 77�7- HP 394. Wm Q / W I @LAR MIN Cz } ~ \ I TG 394.3 0 \ I IE 392.3 WM @ 1% MIN IE / '8 -- I - 12'X12" BROOKS BOX _I--==---- ------------- --- -- --------------�__ = OR EQUAL -FS.9 J J J Y I I I TG 385.6 ------ - -- -- - -- - - --- --- --- --_-_ --- --% ' =__-� =L _ - 1-,-- - -----____-_____�--___ � J- 18 x6" LIE 381.4 --- - - -- - - -- - - -- --- --- - --- --r - WA Y HEAD L (EX 391.5) 1 I % :J' _ G 396.2 4" PERF PIPE / "PVC SQ -I f I FS 3B9.96 TG 3892 \ I i T�, ,9 (EX 386.6) I FG 386.33 I 0 101 LF FG 390.7 TG 389 8 IE 387.0 - 1% MTN I SEEt�AGE PIT I J SEEPAG�Ey PIT 6g -I FG 386.33 \ I c J J , .. .I / _ R OTHERS J J I I 384.05) IE 381.3 L = PER OTHERS- J - / / >f, /i /ii / /up -, RV GARAGE TG 388.9 IE 387.1 \ / - BLDG WALL Tok FF 387.0 I 14. i' IE 397.4 RETAIN RAISED DIRT I - -- / �p ,J % J J / , 84.6 8 MAilk BY PAD 386.33 rw 3B6 3 QlACD I EIIsUAL _\ { I - WG3383 2) co % _ I i TW 3.aO _, - - - 3 6% % 1 FG 386.33 II TF �.97 ' T ICK P(Z DRNEWAY "�` -TG 386.9 I I l EDGE OF ii 388.9 J - / PAD (TYP) 387.5 (EX 391.4) GARAGE ) / 4 WS 18 .00EW (EX 384.05) \ FG 389.33 I 1 PEA. CH RECOMMENDATIOPIS J J .' I IE 8�r6i co- - - - p I \ i 1 -` T 1500 GAL SEPTIC \ _ m -i - 1 J i BUBBLERS(TYP) \ I 6" PVC - ✓ TANK PER OTHERS \ i @ 1% MII� I J \ _7 PLANTER I TG 386 _ _ _ _ = < L \ L. ///////////i////�/////// f // // - a - FG 369.5 I I I -385.3 I � I. 386.9 3B7.0 I I 2' DEEP X 1.5' WIDE \ - t g�►� JTYP� . % II J ADU I VEL SPREADER � �' ' � , I � 385.5 i �S 7. J FS 387.96 FG 386.33 _, 387 \ FF 388.0 I I - (EX 384.4) - J 7 33 1 - /,uu I // i///L/i✓////rii//////�/ir ; id/'. _//,//ice O O PAD 38 . I I I. FG 387 33 I �, 12'X12" BROOKS BOX \ i I I - - - \ FS 387 8 I I I 384.4) I I I u i OR EQUAL . CONNECT \ \ ,f 8.9 i % ' \ FL 3892 �� - - - i I FG 387.33 g" PVC SD IFS 387: 5 I 1 H ORIFICE PLATE � - 7.7 I I I �m '1 1 i I (EX 386.1J @ 1% MIN I I TG 385.6 I I V TW@FS 390.04 TG 397B TG 387.8 I I 127� SET I IE 381.4 TG 397.8 j TG 3B7.6 L I - _ _ Ln _ J I LL I TW 386.3 1 I �f BW@FG 389.3 I IE 3862 \ IE 385.9 IE 385.6 I i -IE 385.3---------- -- - ----- �o- - 0 - o m _ I TW@FG 384.6 _ I ____ _____ _ ___________ __ ____ ______------____------- ------------__------- -----_ __' _ ______ _- _ - (BW@FG 3832) If G 388 5 I 1 I TG 3872 TG 3872 TG 3872 I " 393 . O I IF - I TF 380.97 If -` IE 385.1 IIE 384.9 IE 384.7 I I HEADWALL 3.1 ' MAX EXPOSED HT RET WALL FS .0 II i J SEE SHEET L 7G 388 i 1 I J J a - - I EET 5 - / _, SINGLE FAMILY RESIDENCE �. � � , ,_� _/ I 1 v __-- J 1 I i -� PER STRUCTURAL I S I 387 i J I II % ` Ll FF 390.0 TG 38� - -.�- - - I I TW 386.3 _ \ I. J (II J J I 1 I I I I TW@FG 384.6 R PAD 389.33 � 1 FS 389.96 g 3B6 J I STEPPERS 1 \ I I I I (BW@FG 3832) to I n\ I I PER OTHERS I R ENTION TF 380.97 m J' \ 1 1 ,. J w I I I / m CD ASIN B 1 I J \COVER / J Go m I I 38 > I 12'X12" BROOKS BOX 389.8 .3 �FS.96 I E4 POOL I I OR EQUAL 1 J f� I I J' y A' PCC PATIO J C ii 1 (SEPARATE PERMIT) I I I I IE �Bi:4 I SEPTIC VAULTS I 1 ti j . II I RV M E D TG 398 1' = - f / " . % J° J 1.. I I I CAUTIONS )P A T I O IE 387 % f) 1 I J- I EX. SEEPAGE PIT TEST HOLE 5 r \ VEFiEQ L \ I TGB9.9 PER LOWS 14105 E12 DATED II w q PCC y--- , --- ' 8/30/07. TO BE SECURED O O IE 387-T I;/ \ J / AND BACKFILLED (PATIO f r� 4 l EX. SEPTIC VAULTS J TO BE REMOVED / / Z Z W m q 2% I G 366.311 386.3 I TW 386.3 r77-/I I f -' / - l I / TG 3862 ty I TW@FG 364.6 FS 389.96 - IEIE 77 (BW@FG 80.9 e32� FS 389.96 / W@FG 390.0 I / I R/ l TW 3s6.3 i t FG 398.5at I / W@FG 386.3 Ii I 3.1' MAX EXPOSED I °m° i / / / I (EX�) W@FG 388.0 I l RESERVE PIT I BW@FG 384.6 i I HT PET WALL Y f PER OTHERS TF 380.97 I PER SDRSD C-5 I i i MAX. HT � BHT OF FILL 3.4' / CUT 1� CULENTS I I I l DEEPENED FOOTING � TG 387.3 // l TG 386 8 I I I m m p"i RESERVE PIT �y \ l IE 384.9/� I I 1 CD m I / // IE 386.1 I PER OTHERS I �R / I I i i I FENCE PER I / 1 1 2% P I \ i 125 • OTHERS CACTUS I u 4" PVC N PI�,� @ 1% MIN \ 2%_ \ i i I / \ \ I l / (EX 392.5) I 6" PVC SO \ TGI399.0 FG 399.33 I I \ \ \ TG 386.8 TG 389.0 TG 3872 TG 388.0 \ TG 387.6 TG 3872 38<i•1 FG 389.33 @ 1% MIN !1E1386.3 (EX 388.3) 2!% 13 I - 46 I I + IE 366.6 IE 385.9 �1' IE 38<i.7 \ IE 385.5 IE 38! I-- ----- ---- --_--- ---- -- -- --- I ------------------ ------- �- BdPVC So i C -------_---¢-------- I ---- ----- --------�---------- ----- m TG 387.8 \\ @ 1% MIN - - --- --� j TG 394.7 r-----------------D===-- I J M ol 1.3 rn - - IE 39 - 1 m --------� ---- ---------------------_�_________--_--- ---- _ - _ _ __ _ _ _ _ 1-------------------- -- IE 386.1----------------__ -- --------- -------------------------------- ---- ------------------------------------ � FS`96.0 39 � --- 391 11 I� ---------�� "! - - - - - � ---- �------- 387 ----- 1 \ \ \- -' 2 PYSO CO -A-_ HEADWAL _ PVC SD IE RIM 3 EX. AC DRIVEWAY TO REM�N BYPASS 6" PVC �2% PENCE PER I ' /l FD 1/2" SO. PIN + \ I BYPASS @ 5% \ LIMIT OF GRADING (TYP) S"BB 54 51'E 278.03' OTHERS I / PER ROS 16083 \ __ __ __ __ __ __-__ __ __ __�__ ____� __ _ter______- \ \ \ \ PRIVATE DRIVE \ I FD 3/4" IP Am I B \ I LS 2318 _ APN 262-012-13 / L 1 APN 262-012-12 / / m \ CHAIN LINK FENCE WOOD FENCE r -64B 45 b1S 4.33 J" co If z PASCO LARET SUITER Cm No. 71651 M mExp. 12/31/21� & ASSOCIATES {} CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING GRAPHIC SCALE 1 "-10 S'T CIVIC- P 535 North Highway 101, Ste A, Solana Beach, CA 92075 �� OF CCR ph 858.259.8212 0 £z 858.259.4812 plsaengineering.c®m 0 10 20 30 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: STATION 'ENC-39" INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APPROVED: GRADING PLAN FOR: LOCATION.' 2.5" eBass DISC IN TOP OF CIM Nw PUBLIC WORKS 1349 CREST DRIVE 14747-G QUADRANT OF BMVINGHAM OR & LAKE BRIAN M. ARDOLINO DATE j DATE: 11/23/2020 StP�yPrNdWGlac � d �• � �� OR IN THE MICE OF RETININ PLANNING � . STEVEN NOWAK EDWARD J. WIMER ANDREW & TARA MCMILLIN LIVING TRUST RECORD FROM: ROS 18416 i\, G. - R.C.E. NO.: 71651 LDEV-012506-2020 ELEVATION: 323.983 REVIEWER BRIAN MICHAEL ARDOLINO 12-31-21 APN: 262-012-11 DATUM. NAVD88 SENIOR ENGINEER DATE INSPECTOR EXP.: DATE 12/10/2020 DATE lZIJOlZOZO PLANNING CASE N0: CDP-003420-2019 SHEET 3 OF 5 PLSA 3086 F 11/30/2020 ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPLICANTS PROPERTY. IF ANY DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORK, A WRITTEN LETTER OF PERMISSION FROM THE ADJACENT PROPERTY OWNER MUST BE OBTAINED AND SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ADJACENT PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AND SUBMITTED TO THE CITY IS GROUNDS FOR A STOP -WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION IS OBTAINED. ADDITIONAL NOTES 1. EROSION CONTOL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, GRAVEL BAGS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE. MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS. PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE. 2. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (OCIA) SHALL BE ALLOWED. DCIA MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS, SUCH AS ROOF, ROOF DRAIN DRIVEWAY, AND STREET. 3. ALL PARCELS ARE SUBJECT TO ARCHITECTURAL DESIGN GUIDELINES FOR FUTURE SINGLE-FAMILY RESIDENTIAL DEVELOPMENT. THESE GUIDELINES ARE AVAILABLE AT CITY HALL (505 S. VULCAN AVE, ENCINITAS, CA 92024) AND ARE APPROVED AS PER PC RES. 2006-27. DESIL TING NOTE.' THE PROPOSED AREAS DEDICATED FOR BIORETENTION BASINS SHALL BE USED AS DESILTING BASINS DURING CONSTRUCTION. E w w E E E STABILIZED CONSTRUCTION ENTRANCE PER DETAIL THIS SHEET Y / D L'J I I AV \ \ COMM. POLE BIRD OF \ PARADISEI WIND BREAK I -)E \ E� — — E E- ,—,—, I ,— — -- JE__ J - __ _____________________________ ____ - ---- __-_-_----- �` - -- _-_ -_ - E \ - - - \ / � I \ — ____---- _-L_- ======___ - - _ OVERHEAD 25 / I SILT FENCE PER SE-1 uccOLE SMALy IR ES M BRUSH / & DETAIL THIS SHEET %--------`--� `�ri� i• r :i• r'l :a y:r:�:, ----- O Y �(t:1.F� ,�•r, +G:�`"�J��•;iii•. �.si �.,�,J :.it•':1:\•S`f;r:i.J A:�if:"jhti I I U .-_.:i3:{•:'.�:�t'riJT~:.R•iC:.ii �.'.9�••�.fi••..•r•i' :-:.rlr(`i. :•�;i�:: •l Y.: ri �• � � I --f � � � I W I li 393. 80 FS • �I — 3g4 F- m � m ' Q Q1 394 34 F \ m I I \\ �04. 45 S I I � I' I RVMED VAII1 I I I I 394.33 F EL M I rn I I I 136 I 'i•: Y• GRAVEL BAGS AROUND I 3 / INLET PER SE-6 & DETAIL i THIS SHEET (TYP) m A 1 GL m GF 39 0 C =T- AB \ GAGAGE II I I 387 i W ii I I GRAVEL BAGS AROUND - INLET PER SE-6 & DETAIL II G0 I i THIS SHEET (TYP) 1 II I I 393. O:iF I I O SI GLE FAMIC R IDENCE 393.0 FS I n I ill 0 b � � 4�----- ---� I O II I II I II C_ ---pp 0 I I I it Io j �o � I I �) / i I / I Oo � • j 0 I GRAVEL BAGS AROUND �f INLET PER SE-6 & DETAIL I , II I w — THIS SHEET (TYP) 1 / i i I w I I I c D uccuLEMIs p � / CACTUS I I GAM=---------------- ------ ----_------------- ------ _-- - o> -- p 392 - ------ 9 ' -- 3--_— 386 N �T TF I -I- W M T T \ \ V _ SILT FENCE PER SE-1 T T \ & DETAIL THIS SHEET PR?��nTF °�''HF o I WM w I EROSION CONTROL PLAN NOT TO SCALE 1.SET POSTS AND EXCAVATE A 4 BY 4 IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS LEGEND HATCHED AREA REPRESENTS CONSTRUCTION ENTRANCE ::�=::` ::==• PER DETAIL A GRAVEL BAGS PER DETAIL B o00000000 SILT FENCE PER DETAIL C N 314" MIN COARSE AGGREGATE A p QP�NAELIONq� J CONTRACTOR TO MODIFIY CONSRUCTION �, Z q ti FABRIC �--� 4 IN (10 CM) ENTRANCE IN THE FIELD AS NECESSARY. ORIGINAL ° WIDTH AS REQUIRED o No. 71651 0 LLGRADE } ° . d ° ° °° ° ° 2. ATTACH THE FILTER FABRIC TO CONSTRUCT SEDIMENT BARRIER AND c� Q z m TO ACCOMODATE 3. BACKFILL AND COMPACT THE CHANNELIZE RUNOFF TO SEDIMENT Exp. 12/31/21 a ° ° 4 ANTICIPATED TRAFFIC THE WIRE FENCE AND EXTEND IT EXCAVATED SOIL. TRAPPING DEVICE ° L3L1 ° ° ° ° ° INTO THE TRENCH. Q Ar • °d ° ° ° ° ° ' ° ° ° ° a CIVIC- °d ° ° ° .. , I qIF OF CA�ZFpQ` .lY � e � III � v ° MIN., UNLESS OTHERWISE °d III I FILTER FABRIC SPECIFIED BY A SOILS ENGINEER ° ° °° ° RUNOFF I I I I III�� TWO LAYERS OF GRAVEL I �1 SECTION A -A A BAGS WITH ENDS _ WIRE _ 19' RADIUS OVERLAPPED GAP BETWEEN BAGS MINI PASCO LARET SUITER 50' MIN DETAIL A: CONSTRUCTION ENTRANCE " ACTS AS SPILLWAY-��-� & ASSOCIATES NOT TO SCALE DETAIL B: GRAVEL BAGS CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING NOT TO SCALE DETAIL C: SILT FENCE 535 I\r®rth Highway 101, Ste A, Solana Beach, CA 92075 NOT TO SCALE ph 858.259.8212 0 fa 858.259.4812 I plsaengineering.com CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION.' STATION 'ENC 39• INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APPROVED: GRADING PLAN FOR.' LOCATION., 2.5• BRASS DISC Dv TOP OF CURB NW PLOLIC WOWS Steve/No-wak. • '1349 CREST DRIVE 14747-`71 QUADRANT OF BIF WECHAM OR & LAKE BRIAN M. ARDOLINO DATE DATE: 1112312020 DR IN THE MIDDLE OF RETU3N FLAMBE � STEVEN NOWAK EDWARD J. WIMMER ANDREW & TARA MCMILLIN LIVING TRUST RECORD FROM: ROS 18416 r\, �/tl��— R.C.E. NO.: 71651 LDEV-012506-2020 ELEVATION: 323.983 REVIEKER BRIAN MICHAEL ARDOLINO 12-31-21 APN: 262-012-11 DATUM: NAVDBB SENIOR ENGINEER DATE INSPECTOR EXP.: DATE 12/10/2020 DATE !2llO, 00Z0 PLANNING CASE N0: CDP-003420-2019 SHEET 4 OF 5 PLSA 3088 F 11/30/2020 GENERAL STRUCTURAL NOTES STATEMENT OF SPECIAL INSPECTIONS GENERAL 1, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING WORK, THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES FOUND, 2, THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE ERECTION, SHORING AND BRACING AS REQUIRED FOR STABILITY OF ALL STRUCTURES AND EMBANKMENTS DURING ALL PHASES OF CONSTRUCTION, a IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS OR DETAILS ON THE DRAWINGS. 4, BEFORE COMMENCING EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UNDERGROUND UTILITIES, VALVE PITS OR VAULTS AND SHALL NOT PERFORM WORK THAT WILL DAMAGE THEM OR INTERFERE WITH THEIR SERVICE, 5, STRUCTURAL DIMENSIONS CONTROLLED BY OR RELATED TO ARCHITECTURAL APPURTENANCES OR MECHANICAL OR ELECTRICAL EQUIPMENT SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION, 6, THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE, THEY DO NOT INDICATE METHODS OF CONSTRUCTION, THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT EXISTING AND NEW STRUCTURES DURING CONSTRUCTION, SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING, ET CETERA FOR ALL CONSTRUCTION PHASE LOADS. 7, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK, THE STRUCTURAL ENGINEER WILL NOT ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 8, THE STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED, THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING TEMPORARY SUPPORTS, ETC, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, 9. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK, THE SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, REINFORCED CONCRETE 1, CONCRETE SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS OF 4000 PSI, UNLESS OTHERWISE NOTED, 2, MIX DESIGN REQUIREMENTS; CEMENT SHALL BE TYPE IW; MAXIMUM SLUMP SHALL BE 4" (MAXIMUM SLUMP OF 8" SHALL BE PERMITTED AFTER INTRODUCTION OF A WATER -REDUCING OR SUPER -PLASTICIZER ADMIXTURE); MAXIMUM AGGREGATE SIZE SHALL BE 3/4"; MAXIMUM WATER -CEMENT RATIO SHALL BE 0,45. WEIGHT OF FINE AGGREGATES SHALL NOT EXCEED 43% OF TOTAL WEIGHT OF FINE AND COARSE AGGREGATES COMBINED, THOROUGHLY CONSOLIDATE CONCRETE USING MECHANICAL VIBRATORS. a ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND INSERTS SHALL BE WELL -SECURED IN POSITION PRIOR TO PLACING CONCRETE 4, PROVIDE A 3/4" CHAMFER ON ALL EXPOSED CORNERS UNLESS OTHERWISE NOTED ON THE DRAWINGS, 5. ALL COLD JOINTS SHALL BE ROUGHENED AND CLEANED PRIOR TO PLACING CONCRETE, 6, CONSTRUCTION JOINTS IN CONCRETE INDICATED WITH A ROUGH, CLEAN SURFACE SHALL HAVE A 1/4" MINIMUM AMPLITUDE. REINFORCING STEEL 1, NON -WELDED STEEL BAR REINFORCING SHALL CONFORM TO ASTM A615, GRADE 60. WELDED STEEL BAR REINFORCING AND REINFORCING IN WALLS SHALL CONFORM TO ASTM A706, GRADE 60. 2. BAR LAP SPLICE LENGTHS FOR BARS INSTALLED IN CONCRETE SHALL BE 48 BAR DIAMETERS UNLESS OTHERWISE NOTED ON THE DRAWINGS. a MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED ON THE DRAWINGS: CONCRETE CAST AGAINST EARTH 3" FORMED CONCRETE EXPOSED TO EARTH 2" CONCRETE EXPOSED TO WEATHER 2" ALL OTHER 1 1/2" 4, ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING STEEL SHALL CONFORM TO THE LATEST EDITION OF ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT FOUNDATION 1, UPDATED GEOTECHNICAL INVESTIGATION REPORT FOR PROPOSED McMILLIN RESIDENCE, 1349 CREST DRIVE, ENCINITAS, CALIFORNIA 92024, PREPARED BY CHRISTIAN WHEELER ENGINEERING, JOB NO, CWE 2190113,01, DATED DECEMBER 6, 2019. a. ALLOWABLE SOIL BEARING PRESSURE (SHALLOW FOUNDATIONS) 2,450 PSF b, ALLOWABLE EQUIVALENT FLUID PASSIVE SOIL PRESSURE 300 PSF/FT STRUCTRURAL SPECIAL INSPECTION REPORT PREPARED BY , DATED ON FILE WITH ENGINEERING DIVISION DESIGN CRITERIA 1. DESIGN BUILDING CODE 2. OCCUPANCY CATEGORY a ROOF LIVE LOAD 4, WIND DESIGN CRITERIA: BASIC WIND SPEED WIND EXPOSURE 5, SEISMIC DESIGN CRITERIA, SHORT PERIOD MCE SPECTRAL RESPONSE ACCELERATION, SS 1 SECOND PERIOD MCE SPECTRAL RESPONSE ACCELERATION, S1 SHORT PERIOD MCE SPECTRAL RESPONSE ACCELERATION, Sms 1 SECOND PERIOD MCE SPECTRAL RESPONSE ACCELERATION, SM1 SITE CLASS SEISMIC DESIGN CATEGORY DESIGN SHORT PERIOD MCE SPECTRAL RESPONSE ACCELERATION, SOS DESIGN 1 SECOND PERIOD MCE SPECTRAL RESPONSE ACCELERATION, SD1 SEISMIC FACTORS RESPONSE MODIFICATION FACTOR, R STRUCTURAL OVERSTRENGTH FACTOR, Qo DEFLECTION AMPLIFICATION FACTOR, Cd SEISMIC IMPORTANCE FACTOR, I HORIZONTAL STATIC BASE SHEAR, CS VERTICAL SEISMIC LOAD EFFECT, Ev 2019 CALIFORNIA BUILDING CODE II 20 PSF 110 MPH C 1.115 0,399 1.338 0.599 C D 0.892 0.399 6.5 2.5 4.0 1.0 0.137 W 0.178 D STRUCTURAL REVIEW PERFORMED BY ESGIL, A SAFEBUILT COMPANY, AS PLAN CHECK 2020- 14747-Ge , DATED October 12, 2020 STRUCTURAL OBSERVATION THE OWNER SHALL EMPLOY THE STRUCTURAL ENGINEER OF RECORD, OR ANOTHER ENGINEER DESIGNATED BY THE STRUCTURAL ENGINEER OF RECORD, TO PERFORM STRUCTURAL OBSERVATIONS AS DEFINED IN SECTION 1709 OF THE 2019 CALIFORNIA BUILDING CODE, OBSERVED DEFICIENCIES SHALL BE REPORTED IN WRITING TO THE OWNER'S REPRESENTATIVE, SPECIAL INSPECTOR, CONTRACTOR, AND THE BUILDING OFFICIAL THE STRUCTURAL OBSERVER SHALL SUBMIT TO THE BUILDING OFFICIAL A WRITTEN STATEMENT THAT THE SITE VISITS HAVE BEEN MADE AND IDENTIFYING ANY REPORTED DEFICIENCIES THAT, TO THE BEST OF THE STRUCTURAL OBSERVER'S KNOWLEDGE, HAVE NOT BEEN RESOLVED. STRUCTURAL OBSERVATIONS ARE IN ADDITION TO, AND NOT A SUBSTITUTE FOR, THE SPECIAL INSPECTIONS INDICATED BELOW AND THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY A CITY BUILDING INSPECTOR, STRUCTURAL OBSERVATION SHALL BE REQUIRED AT THE FOLLOWING STAGES OF CONSTRUCTION; 1. FOUNDATIONS; PRIOR TO PLACEMENT OF STRUCTURAL CONCRETE FOR ALL FOOTINGS, ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND OTHER INSERTS (INCLUDING HARDWARE FOR SHEAR WALL HOLD DOWNS) SHALL BE SECURED IN PLACE PRIOR TO CALLING FOR STRUCTURAL OBSERVATION, SPECIAL INSPECTION AND TESTING 1. NOTICE TO THE APPLICANT / OWNER / OWNER'S AGENT / ARCHITECT / ENGINEER OF RECORD; BY USING THESE PERMITTED CONSTRUCTION DRAWINGS FOR CONSTRUCTION / INSTALLATION OF THE WORK SPECIFIED HEREIN, YOU AGREE TO COMPLY WITH THE REQUIREMENTS OF THE CITY OF SAN DIEGO FOR SPECIAL INSPECTIONS, STRUCTURAL OBSERVATIONS, CONSTRUCTION MATERIAL TESTING, AND OFF -SITE FABRICATION OF BUILDING COMPONENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS AND AS REQUIRED BY THE CALIFORNIA CONSTRUCTION CODES, 2, NOTICE TO THE CONTRACTOR / BUILDER / SUB -CONTRACTOR / OWNER -BUILDER; BY USING THESE PERMITTED CONSTRUCTION DRAWINGS FOR CONSTRUCTION / INSTALLATION OF THE WORK HEREIN, YOU ACKNOWLEDGE AND ARE AWARE OF THE REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS. YOU AGREE TO COMPLY WITH THE REQUIREMENTS OF THE CITY OF SAN DIEGO FOR SPECIAL INSPECTIONS, STRUCTURAL OBSERVATIONS, CONSTRUCTION MATERIAL TESTING, AND OFF -SITE FABRICATION OF BUILDING COMPONENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS AND AS REQUIRED BY THE CALIFORNIA CONSTRUCTION CODES, a SPECIAL INSPECTION IS REQUIRED PER CHAPTER 17 OF THE 2019 CALIFORNIA BUILDING CODE AND AS SUMMARIZED BELOW THE OWNER SHALL EMPLOY A SPECIAL INSPECTION AGENCY APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE START OF WORK, COPIES OF ALL INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT OF RECORD, STRUCTURAL ENGINEER OF RECORD, AND CITY BUILDING INSPECTOR IN A TIMELY MANNER. 4, THE SPECIAL INSPECTIONS IDENTIFIED ON THE PLANS ARE IN ADDITION TO, AND NOT A SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY A CITY BUILDING INSPECTOR, 5, A PROPERTY OWNERS FINAL REPORT FORM FOR WORK REQUIRED TO HAVE SPECIAL INSPECTIONS, TESTING, AND STRUCTURAL OBSERVATIONS MUST BE COMPLETED BY THE PROPERTY OWNER, PROPERTY OWNER'S AGENT OF RECORD, ARCHITECT OF RECORD, OR ENGINEER OF RECORD AND SUBMITTED TO THE INSPECTION SERVICES DIVISION, 6. CONTINUOUS INSPECTION SHALL BE PROVIDED DURING THE PERFORMANCE OF WORK REQUIRING SPECIAL INSPECTION, UNLESS OTHERWISE NOTED, WHEN WORK IN MORE THAN ONE CATEGORY OF WORK REQUIRING SPECIAL INSPECTION IS TO BE PERFORMED SIMULTANEOUSLY, OR THE GEOGRAPHIC LOCATION OF THE WORK IS SUCH THAT IT CANNOT BE CONTINUOUSLY OBSERVED, IT SHALL BE THE RESPONSIBILITY OF THE AGENT TO EMPLOY A SUFFICIENT NUMBER OF SPECIAL INSPECTORS TO ASSURE THAT ALL WORK IS CONTINUOUSLY INSPECTED IN ACCORDANCE WITH THOSE PROVISIONS, 7. THE SPECIAL INSPECTORS SHALL BE CERTIFIED BY THE CITY OF SAN DIEGO, DEVELOPMENT SERVICES, TO PERFORM THE CATEGORY OF SPECIAL INSPECTION SPECIFIED. 8, THE CONSTRUCTION MATERIALS TESTING LABORATORY SHALL BE APPROVED BY THE CITY OF SAN DIEGO, DEVELOPMENT SERVICES, FOR TESTING OF MATERIALS, SYSTEMS, COMPONENTS, AND EQUIPMENT. 9, THE CONTRACTOR SHALL NOTIFY THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY PRIOR TO PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION, 10. WHERE MATERIALS OR ASSEMBLIES ARE REQUIRED BY THE CALIFORNIA BUILDING CODE TO BE LABELED, SUCH MATERIALS AND ASSEMBLIES SHALL BE LABELED BY AN AGENCY APPROVED BY THE CITY OF SAN DIEGO IN ACCORDANCE WITH SECTION 170a PRODUCTS AND MATERIALS TO BE LABELED SHALL BE TESTED, INSPECTED AND LABELED IN ACCORDANCE WITH THE PROCEDURES SET FORTH IN SECTIONS 1703,5.1 THROUGH 1703,5A 11. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY FOR CONSTRUCTION OF ITEMS LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTORS STATEMENT OF RESPONSIBILITY SHALL CONTAIN: (1) ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS; (2) ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL; (3) PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION; (4) THE METHOD AND FREQUENCY OF REPORTING AND DISTRIBUTION OF THE SPECIAL INSPECTION REPORTS; AND (5) IDENTIFICATION AND QUALIFICATIONS OF THE PERSON OR PERSONS EXERCISING SUCH CONTROL AND THEIR POSITION IN THE ORGANIZATION, CBC DESCRIPTION OF TYPE OF INSPECTION REQUIRED, DESIGN REF LOCATION, REMARKS, ETCETERA STRENGTH CONCRETE CONSTRUCTION. CONTINUOUS INSPECTIONS; INSPECT BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE; AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE 1705.3 TEMPERATURE OF THE CONCRETE; INSPECTION OF CONCRETE FOR PROPER Pc - 4,000 PSI APPLICATION TECHNIQUES. PERIODIC INSPECTIONS; INSPECTION OF REINFORCING STEEL AND PLACEMENT; VERIFICATION OF USE OF REQUIRED DESIGN MIX; INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES; INSPECT FORMWORK FOR SHAPE, LOCATION, AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED, SOILS, PERIODIC INSPECTIONS; VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY; VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER SEE 1705.6 MATERIAL; PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL FOUNDATION MATERIALS; OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED NOTES THIS PROPERLY PRIOR TO PLACEMENT OF COMPACTED FILL SHEET CONTINUOUS INSPECTIONS; VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL STRUCTURAL OBSERVATIONS 1709 SEE THE "STRUCTURAL OBSERVATIONS" NOTES PRECEDING THE "SPECIAL INSPECTION AND TESTING" NOTES, "00o : 0Z4R./ #5 CONT cr c\, 8" SOLID FIN GRADE PER CIVIL GROUTED CMU #5 @ 16" OC HORIZ #5 @ 16" OC VERT i #5 @ 16" OC W/ 39' MIN CONTACT LAP SPLICE FIN GRADE PER CIVIL CONT WATERPROOFING III=1I1= MEMBRANE CLEAN, ROUGHENED SURFACE • i #5 @ 12, OC W/ i 2" CLR STD 90 DEG HK i TOP &BOTTOM #5 @ 12, OC TOP & BOTTOM i i i 2x4 KEY mm v BIORETENTION RETAINING WALL DETAIL SCALE; 3/4" = 1'-0" OPESSIO No.55314' Exp. 9/30/22 S ti �RVCTU F OF CAL14 1870 Cordell Court Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com HANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS "�""'" 0'' "" fF_`'r`VF_" D' ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. B MVBD' DESCRIPTION: STATION "ENC-39" LOCATION: 2.5" RRASS nIqC: IN T(1P nl- NW UADR(MFTBOF BIRMINGHAM DR & INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: 10/15/2020 R.C.E. NO.: 5314 g,,�S' - MARK S. VAN BIBBER EXP.: 9/30/2022 RECOMMENDED: APPROVED: StP2vP�IVOivGt �°�, � 2� m� STEVE NOWAK EDWARD J. WIMMER DATE 12 10 2020 DATE /z ro zozo GRADING PLAN FOR: 1349 CREST DRIVE ANDREW & TARA MCMILLIN LIVIING TRUST APN: 262-012-11 PLANNING CASE NO: CDP-003420-2019 14747-G LDEV-012506-2020 ------- BRIAN M. ARDOLINO DATE — PLANNING REVIEWER RECORD FRCU3.983 SENIOR ENGINEER DATE1 INSPECTO—R-7 SHEET 5 OF 5 ELEVATION: DATUM: NAVD88