2020-14641 G - LDEV-012763-2020 (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS /HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NO TE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORTS TITLED "REPORT OF PRELIMINARY GEOTECHNICAL INVESTIGATION F STREET RESIDENTIAL DEVELOPMENT" DATED JANUARY 30, 2019, PREPARED BY CHRISTIAN WHEELER ENGINEERING SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT OF WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. : ��i9: 7�����■»: 7�I��y[ �P► �y7I_ 1��: 3�i]: �Lll�l�: l�il :�_1��'Li]y�9���e1:L1:71�[elI 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE - CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE - CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633 -2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND /OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT 14641 -G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. 18. IF ANY ARCHAEOLOGICAL, HISTORICAL, OR PALEONTOGICAL RESOURCES ARE INADVERTENTLY DISCOVERED GRADING ACTIVITY, THE PROJECT CONTRACTOR SHALL DIVERT, DIRET OR TEMPORARILY HALT GROUND- DISTURBING ACTIVITIES IN THE AREA OF DISCOVERY TO ALLOW EVALUATION OF THE SIGNIFICANCE OF SUCH RESOURCES. THE PROJECT APPLICANT SHALL IMMEDIATELY NOTIFY DEVELOPMENT SERVICES DEPARTMENT STAFF OF SUCH FINDING AT THE TIME OF DISCOVERY. THE SIGNIFICANCE OF THE DISCOVERED RESOURCE(S) SHALL BE DETERMINED BY A QUALIFIED ARCHAEOLOGIST, HISTORIAN, OR PALEOTOLOGIST IN CONSULTATION WITH THE DEVELOPMENT SERVICES DEPARTMENT AND, FOR ARCHEOLOGICAL RESOURCES, THE NATIVE AMERICAN COMMUNITY. THE DEVELOPMENT SERVICES DIRECTOR MUST CONCUR WITH THE EVALUATION PROCEDURES AND ANY NECESSSARY DATA RECOVERY SERVICES BEFORE GRADING ACTIVITIES ARE ALLOWED TO RESUME. 19. AS SPECIFIED BY CALIFORNIA HEALTH AND SAFETY CODE SECTION 7050.5, IF HUMAN ARE FOUND ON THE PROJECT SITE DURING CONSTRUCTION ACITIVITY, THE PERSON RESPONSIBLE FOR THE EXCAVATION, OR HIS OR HER AUTHORIZED REPRESENTATIVE, SHALL IMMEDIATELY NOTIFY THE SAN DIEGO COUNTY CORONER'S OFFICE BY TELEPHONE. NO FURTHER EXCAVATION OR DISTRUBANCE OF THE DISCOVERY OR ANY NEARBY AREA REASONABLY SUSPECTED TO OVERLIE ADJACENT REMAINS, AS DETERMINED BY A QUALIFIED ARCHAEOLOGIST AND /OR A TRADITIONALLY AND CULTURALLY AFFILIATED (TCA) NATIVE AMERICAN MONITOR, SHALL OCCUR UNTIL THECORONER HAS MADE THE NECESSARY FINDINGS AS TO ORIGIN AND DISPOSITION PURSUANT TO PUBLIC RESOURCES CODE 5097.98. IF SUCH A DISCOVERY OCCURS, A TEMPORARY CONSTRUCTION EXCLUSION ZONE SHALL BE ESTABLISHED SURROUNDING THE AREA OF THE DISCOVERY SO THAT THE AREA WOULD BE PROTETED (AS DETERMINED BY THE QUALIFIED ARCHAEOLOGIST AND /OR THE TCA NATIVE AMERICAN MONITOR), AND CONSULTATION AND TREATMENT COULD OCCUR AS PRESCRIBED BY LAW AS FURTHER DEFINED BY STATE LAW, THE CORONER WOULD DETERMINE WITHIN TWO WORKING DAYS OF BEING NOTIFIED IF THE REMAINS ARE SUBJECT TO HIS OR HER AUTHORITY. IF THE CORONER RECOGNIZES THE REMAINS TO BE NATIVE AMERICAN, HE OR SHE SHALL CONTACT THE NATIVE AMERICAN HERITAGE COMMISSION (NAHC) WITHIN 24 HOURS. THE NAHC WOULD MAKE A DETERMINATION AS TO THE MOST LIKELY DESCENDENT. IF NATIVE AMERICAN REMAINS ARE DISCOVERED, THE REMAINS SHALL BE KEPT IN SITU ( "IN PLACE "), OR IN A SECURE LOCATION IN CLOSE PROXIMITY TO WHERE THEY WERE FOUND, AND THE ANALYSIS OF THE REMAINS SHALL ONLY OCCUR ON -SITE IN THE PRESENCE OF THE TCA NATIVE AMERICAN MONITOR. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOSEPH DIASPARRA AT 201 - 647 -7743, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP /IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP /IMP FACILITIES AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITY AND /OR THE TURF /LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP /BMP. 6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON- COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY - APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT: CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS: A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL PANELS /PLATES. CONSTRUCTION VEHICLES: A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL: EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST - GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING: CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT: CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS /DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON- RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436 -4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633 -2770. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - CSD - (760)- 633 -2770 B. GAS & ELECTRIC - SDGE - (760)- 438 -6200 C. WATER - SAN DIEGUITO WATER DISTRICT -1- 800 - 227 -2600 D. TELEPHONE - SBC BELL - (760)- 489 -3411 E. CABLE TV - COX COMMUNICATIONS - (760)- 806 -9809 X -2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)- 633 -2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. CHANGE NO.I DESCRIPTION I APPROVED I DATE I BENCHMARK I AS -BUILT APPROVALS CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. ELEVATION = 92.004' DATUM = NAVD 88 STEVEN R. JONES SENIOR ENGINEER DATE DATE PUBLIC WORKS PLANNING REVIEWER INSPECTOR SAN DIEGUITO WATER DISTRICT NOTES 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON- EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES WHICH MAY AFFECT FINAL DESIGN I.E. LINE CROSSING LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND /OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6. MINIMUM HORIZONTAL SEPARATION OF 10 -FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB -1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC -17 OR WC -18. 0 WNERS CERTIFICATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. SIGNATURE: ------------------ - - - - -- DATE: --------------- JOSEPH DIA PARRA, MANAGER "F" STREET PROJECT, LLC SOILS ENGINEER'S CERTIFICATE I, DANIEL B. ADLER, A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON JANUARY 30, 2019 ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEEER, FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN INCO RATED THE GRADING PLANS AND SPECIFICATIONS. SIGNED: rrc�_,)C SS /p4 R.C.E.: 36037--------- - - - - -- EXP. DATE:6�30�??600 22 JOB #: ____.00LE21$Qa,5_8_Ql ---------- V EXP. /3 CHRISTIAN WHEELER ENGINEERING t�q 3980 HOME AVENUE F A SAN DIEGO, CA 92105 619- 550 -1700 STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFOMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHINICAL SUFFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN, AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBUITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. BY: 9 -8 -2020 STEVEN R. JONE DATE FESS RCE 65124 QF\0 I pN c cD Co COASTAL LAND SOLUTIONS, INC. d No . 65124 .Zo C� 577 SECOND STREET L ENCINITAS, CA 92024 VIC �P i� PH (760) 230 -6025 9TF OF CA�ZF�P� 1� FAX (760) 230 -6026 U4 < c ��+ ° E T. v SITE -� ❑❑ z ❑F T. m REQUEZA ST. z m ❑ ❑� z ° S 0 ° o F �� EBARD = z❑ m v� SANTA FE DR. �j VICINITY MAP 0 WNER/PERMITTEE JOSEPH DIASPARRA 2223 AVENIDA DE LA PLAYA #300 LA JOLLA, CA 92037 -3218 201 - 647 -7743 SITE ADDRESS 66, 76, AND 84 F STREET ENCINITAS, CA 92024 APN# 258 - 202 -23, 24, AND 25 LOTS 18, 20, 22, AND 24 IN BLOCK B OF MCNIELL AND KEY'S SUBDIVISION OF EAST BLOCK 6 OF ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 112 FILED IN THE COUNTY SAN DIEGO COUNTY RECORDER OFFICE RECORDED APRIL 5, 1887. SEE CERTIFICATE OF COMPLIANCE RECORDED ON DECEMBER 5, 2017 AS FILE NO. 2017 - 566393 OF OFFICIAL RECORDS. EARTHWORK QUANTITIES: EXCAVATION (CUT) 3,232 CUBIC YARDS EMBANKMENT (FILL) 75 CUBIC YARDS 3,157 CUBIC YARDS EXPORT MAX. DEPTH OF CUT: 12 FEET MAX. DEPTH OF FILL: 3 FEET R"ERVIOUS SURFACE: EXISTING IMPERVIOUS AREA = 4,000 sf PROPOSED IMPERVIOUS AREA = 9,900 sf REPLACED IMPERVIOUS AREA = 4,000 sf EXISTING SITE AREA = 15,841 sf NOTES: 1. ANY EXISTING IMPROVEMENTS THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED AND /OR REPLACED TO THE SATISFACTION OF THE CITY ENGINEER PRIOR TO FINAL APPROVAL. 2. THE EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE. IF ANY MONUMENT IS DISTURBED OR DESTROYED IT SHALL BE REPLACED BY A LICENSE LAND SURVEYOR AND SHALL FILE A CORNER RECORD WITH THE COUNTY OR BE INCLUDED WITH FINAL PARCEL MAP. 3. ALL SERVICE LINES TO THE SUBJECT BUILDINGS SHALL BE CONSTRUCTED CONSTRUCTED UNDERGROUND. 4. REFER TO ARCHITECTURAL SITE PLAN FOR WALL FINISHES AND COLORS. SHEET INDEX SHEET NO. 1 TITLE SHEET SHEET NO. 2 GRADING AND DRAINAGE PLAN SHEET NO. 3 SECTIONS AND DETAILS SHEET NO. 4 EROSION CONTROL PLAN SHEET NO. 5 SHORING PLAN PREPARED BY COASTAL LAND SOLUTIONS, INC. 577 SECOND STREET ENCINITAS, CA 92024 760 - 230 -6025 DATE OF SURVEY: OCTOBER 11, 2018 BY SAMPO ENGINEERING INC. BMP PROJECT STATUS _►O_ ull PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION I SAN DIEGUITO WATER DISTRICT I ENCINITAS FIRE DEPARTMENT INT. I DATE PLANS PREPARED STEVEN cl 1� .LD DATE �IVD THE SUPERVISION OF DATE: 9 -8 -2020 R.C.E. N0. 65124 S EXP. 9 -30 -21 SDWD W20 -030 () ` 9/25/2020 \ 9/23/20 0J°/2V2020 lqcdw.+ J.� DATE SIGN DATE SIGN DATE SIGN DATE (SIGNATURE EXPIRES 2 YEARS AFTER DATE) ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. RECOMMENDED APPROVED GRADING PLAN FOR: A.P.N. #258- 202 -23, 24, AND 25 StevelNawak. Y. V., F STREET PROJECT, LLC 14641- G STEVE NOWAK EDWARD J. WIMMER 66, 76, AND 84 F STREET 9/3012020 9' /301zozo ENCINITAS, CA 92024 LDEV- 012763 -2020 DATE DATE PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 1 OF 8 F: \MISC \185 CLS 1585 fancornis F street (Encinitas) \CLS #1585 FCORNISH GP 9 -4 -20 v43.pro U z 0 0 F a 0 U ALL MONUMENTS CALLED OUT AS TO BE PROTECTED IN PLACE OR REPLACED AFTER CONSTRUCTION TO BE VERIFIED PRIOR TO FINAL AS- BUILTS AND CONFIRMED OR REPLACED AS NEEDED BY A LICENSED LAND SURVEYOR. l TWOFS= 156.21 BWOEX= 153.00 GRAPHIC SCALE 1 " =10' 0 10 20 30 COASTAL LAND SOLUTIONS, INC. C LI� 577 SECOND STREET ENCINITAS, CA 92024 PH (760) 230 -6025 FAX (760) 230 -6026 GRADING AND DRAINAGE PLAN NOTES: 1. REMOVE ALL EXISTING ONSITE TREES AND STREET TREES WITHIN THE ROW. SEE LANDSCAPE PLAN FOR LOCATION OF NEW STREET TREES BY OTHERS PLAN VIEW SCALE: 1"=10' CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. PUBLIC WORKS ELEVATION = 92.004' PLANNING DATUM = NAVD 88 STEVEN R. JONES DATE REVIEWER SENIOR ENGINEER DATE INSPECTOR EX =154.09 TRENCH RESURFACING PER SDRSD G -24A (TYPICAL) W � — TWOFS= 158.00 BWOFS- 05� TC=158.00 FS- 157.50 TC =157.43 EX- 154.50 3 / i ti EXz/154.25 BELGARD PERMEABLE PAVING STONE OR EQUAL 2" THICK NO.8 AGGREGATE 4" THICK NO.57 AGGREGATE 6" THICK 3/4" CRUSHED ROCK — 0.33' (LESS THAN 5% OF I 3/4" CRUSHED ROCK BASE (6" THICK) COMPACTED SOIL SUBGRADE T'VDTr4 A T 1010101►AD A DT 1Q D A 17VD C AND TRUNCATED DOME MAT G -27 AND G -30 EXISTING GRADE 6" PVC PIPE INLET WITH 2'x2' x 6 "0 ROCK DISSIPATOR 2 M AND PLANTS AT 188" " O.C. O. MIN. *12" ENGINEERED SOIL / 3" THICK 3/8 AGGREGATE) * *12" THICK 3/4" CRUSHED ROCK RATIVE GRAVEL /PLANTING IN PLACE CONCRETE PAVER CUSTOM PERMFARLE PAVERS (DRIVEWAY) N TS UGb1bIVGU 6T: Uh{A CT: �nt�rt Sn CT: ENGINEERING DIVISION APPROVALS SRJ SRJ SCE E INT. DATE PLANS PREPARED D R THE SUPERVISION OF RECOMMENDED APPROVED DATE: 9 -8 -2020 StieyerNoAy0Lk e ec.d Y. v., R.C.E. N0. 65124 STEVE NOWAK EDWARD J. AMMER STEVEN ES EXP. 9 -30 -21 DATO /2020 DATE lZOZO LEGEND S.D.R.S.D. = SAN DIEGO REGIONAL STANDARD DRAWINGS PROPERTY BOUNDARY EXISTING EASEMENT PROPOSED CONTOURS 255 EXISTING CONTOURS 255 EXISTING EDGE OF PAVEMENT CENTERLINE — EXISTING WATER MAIN _w _w EXISTING SEWER MAIN _S _s EXISTING ELECTRIC LINE EXISTING JOINT POLE C-Q, EXISTING BUILDING EXISTING HARDSCAPE EXISTING FENCE EXISTING BLOCK WALL BUILDING FOOTPRINT DRAINAGE DIRECTION X X- FLOWLINE SWALE E - -- BELGARD PERMEABLE PAVERS (PARKING) OVER 2" THICK 3/8" BEDDING COURSE OVER 4" THICK 1/2" CHOCKER COURSE OVER 6" THICK 3/4" CRUSHED ROCK CUSTOM PERMEABLE PAVERS (DRIVEWAY) 4" CONCRETE HARDSCAPE I . 4" PERVIOUS CONCRETE (DRIVEWAY) 4" DG PATH GRASSCRETE /TURFSTONE (DRIVEWAY) DEEPEND FOOTING /STEM WALL SDRSD SEWER LATERAL SS -01, SS -02 WATER SERVICE, WS -01 6" CONCRETE CURB B -1 CMU RETAINING WALL C- SERIES 3" PVC STORM DRAIN PIPE 6" AND 12" NDS AREA DRAIN INLET 6" TRENCH DRAIN, (TRAFFIC RATED) WITH SUMP AND PUMP DOWNSPOUTS BUILDING SUBDRAIN TO CONNECT TO SEPARATE SUMP & PUMP S OS W�W 991.0 HATCHED AREA REPRESENTS LANDSCAPED TREATEMENT AREA FOR BEST MANAGEMENT PRACTICE TO BE CONSTRUCTED TO SPECIFICATIONS OF BIORETENTION DETAIL ON PAGE 7, APPENDIX C -3 OF THE ENCINITAS STORMWATER MANUAL. AREA NOT TO BE MODIFIED WITHOUT PERMIT FROM THE CITY. REQUIRED BASIN AREA = 4% x 9,900 sf = 396 sf PROPOSED BASIN AREA = 426 sf R/W 12" AREA DRAIN — RETAINING WALL PER SDRSD C -4 OR EQUAL TW= 157.00 1' TO 2' TYPE A DIKE CORNISH /---SAWCUT _DRIVE 4" HMA OVER 12" CLASS II BASE D -27 UNDERDRAIN *BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 12" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 65% SAND, 15% COMPOST OR HARDWOOD MULCH, AND 20% TOPSOIL. * *3 4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENDED TO INC EASE THE INFILTRATION AND STORAGE ABILITY OF THE BASIN. THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON ENCINITAS STORMWATER MANUAL CALCULATIONS. TYPICALLY, THE SURFACE AREA OF THE BIORETENTION BASIN IS 4% OF THE IMPERVIOUS AREA DRAINING TO IT. NO LINER SECTION E - BIORETENTION BASIN SCALE: 1 " =4' QPpFESSIpN R. c w 'o No . 65124 rmn CC 3TgT CIVIC \ \OF CA\- CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT I DRAWING NO. GRADING PLAN FOR: A.P.N. #258- 202 -23, 24, AND 25 F STREET PROJECT, LLC 14641 - G 66, 76, AND 84 F STREET ENCINITAS, CA 92024 LDEV- 012763 -2020 PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 2 OF 8 U z 0 0 H 0 U CMU RETAINING WALL PER SDRSD C -1 OR EQUAL CMU RETAINING WALL PER SDRSD C -1 OR EQUAL R/W CENTERLINE F STREET 4" HMA OVER 12" CLASS II BASE C/L STRIPE EX= 151.19 2" GRIND AND OVERLAY TO STREET CENTERLINE EX 6" MAIN IE= 142.59 SECTIONS AND DETAILS 32.50' 22.66' 12' FL EXISTING GRADE SAWCUT EP 1, P 4.5' 4' 8.57' 5.93' 12.16' 6' .1 4% 15% 5% - -� 15% GRASSCRETE-j y h � CUSTOM h o o N PERMEABLE m PAVERS U R/W CENTERLINE F STREET R/W 32.50' 20' TC 12' _I SAWCUT EP F EP= 154.22 CA STRIPE EX= 154.78 1 1. 57. - - - - -- 7=- 4" INCH HMA OVER �o 12" CLASS II BASE 6" FLUSH CURB 18" DEEP J�' EX 6" MAIN (DEAD END) IE= 145.79 P/L BIORETENTION BASIN I SEE TYPICAL DETAIL X FS= 155.60 t = Ylu7_ III PA I. G WALL ST FF =1 I , GARAGE= 146.83 : I [ u X111 =� 1Lt= LLt= LLt= LLF �- '' -1 I IJ I Lam- III -I I �I i i -I i Iii i i -i i �i i i -i COASTAL LAND SOLUTIONS, INC. C LL� � 577 SECOND STREET ENCINITAS, CA 92024 PH (760) 230 -6025 FAX (760) 230 -6026 TW= 158.00 4.5' FS= 155.65 15% 1 � PCC SIDEWALK PER SDRSD G -07 6" CONCRETE CURB PER SDRSD G -07 18" DEEP BELGARD PERMEABLE PAVERS P/L 10% 4� SECTION A SCALE: 1"=8' 26.64' PA 20' FIRST FF= 156.33 TRENCH GRATE TG= 146.55 GF= 146.63 1 GARAGE 3' DEEPEND FOOTING AT GARAGE (TYPICAL) BUILDING WALL TG- 157.40 IE= 156.57 CMU RETAINING WALL PER SDRSD C -1 OR EQUAL CMU RETAINING WALL PER SDRSD C -5 OR EQUAL CMU RETAINING WALL PER X SDRSD C -5 OR EQUAL _ _ _ - - - - - - - FS= 160.40 FS= 157.40 P�L 5' SYSB FENCE BY OTHERS CMU RETAINING WALL PER SDRSD C -4 OR EQUAL ------ - - - - -- CMU RETAINING WALL PER SDRSD C -1 OR EQUAL CHANGE NO. DESCRIPTION APPROVED DATE FS= 158.00 BENCHMARK P/L V BASIN SUBDRAIN TO CONNECT TO ONSITE ARE DRAIN SYSTEM (TYPICAL) CMU RETAINING WALL PER SDRSD C -5 OR EQUAL FIRST FF= 161.00 SECTION B SCALE: 1"=8' I BASEMENT FF= 145.83 I 20' P/L TW= 161.83 FF= 158.00 2 " FS= 157.63 GRASSCRETE /TURFLOCK PERMEABLE PAVERS CMU RETAINING WALL PER SDRSD C -1 OR EQUAL _, FENCE BY OTHERS-----_ CMU RETAINING WALL PER SDRSD C -5 OR EQUAL X ' FINISH GRADE 2 I 2" MULTCH *12" ENGINEERED SOIL 3" THICK 3/8 AGGREGATE TOP OF GRATE IS 6" INCHES ABOVE BASIN TYPICAL 2' I -PLA TS 18" O.C. MIN. INSTALL 30 MIL LINER AT SIDES AND BOTTOM • OF ALL BASINS UNITS 1 -4 * *12" THICK 3/4" CRUSHED ROCK •° 0 ° 4" PERFORATED SUBDRAIN CONNECT TO AREA DRAIN 3" SOLID PIPE OUTLET * BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 12" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 65% SAND, 15% COMPOST OR HARDWOOD MULCH, AND 20% TOPSOIL. **3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENDED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE BASIN. THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON ENCINITAS STORMWATER MANUAL CALCULATIONS. TYPICALLY, THE SURFACE AREA OF THE BIORETENTION BASIN IS 4% OF THE IMPERVIOUS AREA DRAINING TO IT. INSTALL 30 MIL LINER AT SIDES AND BOTTOM OF ALL BIORETENTION BASINS AT UNITS 1 -4 TYPICAL BIORETENTION BASIN SCALE: 1"=2' NOTE - SPECIAL INSPECTION REQUIRED: PRIOR TO OCCUPANCY, FINAL INSPECTION, RELEASE OF SECURITIES, AS- BUILTS, AND /OR GRADING PLAN SIGNOFF, WHICHEVER MAY COME FIRST, THE ENGINEER OF RECORD SHALL FIELD SURVEY AND VERIFY THAT THE CONSTRUCTED IMPERVIOUS SURFACE IS LESS THAN 10,000 SF. A SIGNED AND STAMPED INSPECTION REPORT SHALL BE PROVIDED TO THE ENGINEERING FIELD INSPECTOR. IF 10,000 SF OR MORE OF IMPERVIOUS SURFACE IS CREATED, THE PROJECT SHALL BE CONSIDERED A PRIORITY DEVELOPMENT PROJECT FOR PURPOSES OF STORMWATER QUALITY TREATMENT AND SHALL COME INTO FULL COMPLIANCE WITH THE PROVISIONS OF THE NPDES MS4 PERMIT AND THE CITY OF ENCINITAS BMP DESIGN MANUAL. IMPERVIOUS AREA SPECIAL INSPECTION REPORT PREPARED BY DATED _______________ ON FILE WITH ENGINEERING DIVISION. p/L OTHERS E(TYPICAL) BIORETENTION BASIN R/W SEE TYPICAL DETAL 20' CMU RETAINING WALL PER �SDRSD C -1 OR EQUAL EXISTING GRADE - CUSTOM PERMEABLE PAVERS (DRIVEWAY) 4' 4' TC 12' FS= 160.40 - - - - - - - GRASSCRETE /TURFBLOCK --1' SAWCUT 9.677 2% �2" GRIND /OVERLAY TO CENTERLINE ­4" HMA OVER 12" CLASS II BASE MODIFIED G -14 A/D DRIVEWAY APRON Tj G -7 SIDEWALK SECTION C 12" CLASS II BASE SCALE: 1"=8' FIRST FF= 161.00 I FS= 160.40 III FS= 160.40 I --- - - - - -- -- TRENCH DRAIN TG= 148.22 TRENCH DRAIN TG= 146.55 Ir CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. ELEVATION = 92.004' DATUM = NAVD 88 SECTION D SCALE: 1"=8' P/L WOOD FENCE BY P/L OTHERS (TYPICAL) B 5' SYSB CMU RETAINING WALL PER SDRSD C -1 OR EQUAL FLOWLINE F STREET - -- TRENCH DRAIN TG= 148.22 TRENCH DRAIN TG= 151.22 SECTION F SCALE: 1"=8' BUILDING WALL EXISTING GRADE BASIN FS= 156.00 FF= 158.00 5% BIORETENTION BASIN - SEE DETAIL THIS SHEET CMU RETAINING WALL PER`/ SDRSD C -1 OR EQUAL P NOTE: ALL BASIN SUBDRAINS SHALL DRAIN TO CURB VIA GRAVITY. DRIVEWAY SUMP PUMPS SHALL DRAIN TO BASINS AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: SRJ SRJ SCE INT. DATE PLANS PREPARED D R THE SUPERVISION OF PUBLIC WORKS DATE: 9 -8 -2020 STEVEN R. JONES DATE PLANNING REVIEWER STEVEN ES R.C.E. N0. 65124 SENIOR ENGINEER DATE INSPECTOR EXP. 9 -30 -21 R W CENT RLINE CORNISH AVE. R/W CENT RLINE R/W CORNISH DRIVE 20' 8' TB 12' 5.5' TYPE A DIKE 2% r-1' SAWCUT _�-4" HMA OVER L4" DG PATH 12" CLASS II BASE U z 1-1 QPOFESSIpN R. O U-1 No. 65124 m L � 3T CIVIC �tiP qTF OF CA�ZF�P 1--I ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. RECOMMENDED St -eVPi NOiUCLk STEVE NOWAK 9/30/2020 DATE APPROVED GRADING PLAN FOR A.P.N. #258- 202 -23, 24, AND 25 F STREET PROJECT, LLC 14641 - G EDWARD J. WIMMER 66, 76, AND 84 F STREET 9'/3olzozo ENCINITAS, CA 92024 LDEV- 012763 -2020 0 DATE PLANNING CASE N0. MULTI2940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 3 OF 8 (, RUNOFF GAP BETWEEN BAGS ACTS AS SPILLWAY TWO LAYERS OF GRAVEL BAGS WITH ENDS OVERLAPPED DETAIL GRAVEL BAGS NTS NOTE: CONSTRUCT SEDIMENT BARRIER AND CHANNELIZE RUNOFF TO SEDIMENT TRAPPING DEVICE COARSE AGGREGATE FI L TER FABRIC ORIGINAL GRADE 1.1' MIN., UNLESS OTHERWISE SPECIFIED BY A SOILS ENGINEER SECTION A -A n °e ° e o a ° ° A ° ° WIDTjI AS �EQUIRED a TO ACCOMODATE ° ANTICIPA -FED TRAFFIQ° e o ° ° U ° ed e ° ° 10' RADIUS MIN. 25' A CONSTRUCTION ENTRANCE N TS GRAPHIC SCALE 1 ''=10' 0 10 20 30 i I I I I I I I I I I I I I I I I I I I I jI I II / L 1 l �1SO N, N1� COASTAL LAND SOLUTIONS, INC. C L577 SECOND STREET ENCINITAS, CA 92024 PH (760) 230 -6025 FAX (760) 230 -6026 CHANGE N0. DESCRIPTION APPROVED DATE BENCHMARK \ �s7 Nualrol'a "I limme SILT FENCE 1 1 Ste\ CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. ELEVATION = 92.004' DATUM = NAVD 88 STEVEN R. JONES SENIOR ENGINEER DATE DATE 1s9\ PLAN VIEW SCALE: 1"=10' PUBLIC WORKS PLANNING REVIEWER INSPECTOR i Cr) L0 X1 W 4 UeaIUNMU 6T: UMAIVN CIT: LrltLKtU UT. ENGINEERING DIVISION APPROVALS SRJ SRJ SCE INT. DATE P:STEVEN S PREPARED E THE SUPERVISION OF RECOMMENDED APPROVED DATE: 9 -8 -2020 StieyerNOWL -k- �ioecvazoCY. '2f%inw,le�' R S R.C.E. N0. 65124 STEVE NOWAK EDWARD J. AMMER 9/30/2020 fl3o/zozo EXP. 9 -30 -21 DATE DATE i CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. ELEVATION = 92.004' DATUM = NAVD 88 STEVEN R. JONES SENIOR ENGINEER DATE DATE 1s9\ PLAN VIEW SCALE: 1"=10' PUBLIC WORKS PLANNING REVIEWER INSPECTOR i Cr) L0 X1 W 4 UeaIUNMU 6T: UMAIVN CIT: LrltLKtU UT. ENGINEERING DIVISION APPROVALS SRJ SRJ SCE INT. DATE P:STEVEN S PREPARED E THE SUPERVISION OF RECOMMENDED APPROVED DATE: 9 -8 -2020 StieyerNOWL -k- �ioecvazoCY. '2f%inw,le�' R S R.C.E. N0. 65124 STEVE NOWAK EDWARD J. AMMER 9/30/2020 fl3o/zozo EXP. 9 -30 -21 DATE DATE i \ 3 y4 3 I / 3 i ti LEGEND SAND /GRAVEL BAGS (2 HIGH) SILT FENCE 1. SET POSTS AND EXCAVATE A 4BY4IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS. 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. II I (((( III I I I 00000000 x X- 2. STAPLE WIRE FENCING TO THE POSTS. 4 IN (10 CM) 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. FILTER FABRIC WIRE DETAIL SILT FENCE DESILTING BASIN NOTE: BIORETENTION BASINS SHALL BE EXCAVATED AND USED AS DESILTING BASINS DURING CONSTRUCION. THE SILT SHALL BE COMPLETELY REMOVED AND THE BIORETENTION BASINS COMPLETED ONCE FINAL SITE STABILIZATION IS ACHIEVED, PRIOR TO OCCUPANCY AND /OR FINAL. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOSEPH DIASPARRA, 201 - 647 -7743 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. U 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE M� NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO Mai AREAS WHEN IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. .. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. z 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY 0 FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9 QPpFESSION 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE �O N R. 4l AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN 0 PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT co �N z AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 0 w No. 65124 m 10. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE rt a EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED WITH PUNCHED STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 3'T CjVIL �P OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE STATE qTF OF Cpl -ZF�P� OF CALIFORNIA DEPARTMENT OF CONSERVATION. CITY OF ENCINITAS — DEVELOPMENT SERVICES DEPARTMENT DRAWING N0. EROSION CONTROL PLAN FOR: A.P.N. #258- 202 -23, 24, AND 25 F STREET PROJECT, LLC 14641 - G 66, 76, AND 84 F STREET 0 ENCINITAS, CA 92024 LDEV- 012763 -2020 U PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 4 OF 8 3 � / / i \ 3 y4 3 I / 3 i ti LEGEND SAND /GRAVEL BAGS (2 HIGH) SILT FENCE 1. SET POSTS AND EXCAVATE A 4BY4IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS. 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. II I (((( III I I I 00000000 x X- 2. STAPLE WIRE FENCING TO THE POSTS. 4 IN (10 CM) 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. FILTER FABRIC WIRE DETAIL SILT FENCE DESILTING BASIN NOTE: BIORETENTION BASINS SHALL BE EXCAVATED AND USED AS DESILTING BASINS DURING CONSTRUCION. THE SILT SHALL BE COMPLETELY REMOVED AND THE BIORETENTION BASINS COMPLETED ONCE FINAL SITE STABILIZATION IS ACHIEVED, PRIOR TO OCCUPANCY AND /OR FINAL. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOSEPH DIASPARRA, 201 - 647 -7743 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. U 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE M� NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO Mai AREAS WHEN IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. .. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. z 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY 0 FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9 QPpFESSION 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE �O N R. 4l AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN 0 PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT co �N z AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 0 w No. 65124 m 10. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE rt a EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED WITH PUNCHED STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 3'T CjVIL �P OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE STATE qTF OF Cpl -ZF�P� OF CALIFORNIA DEPARTMENT OF CONSERVATION. CITY OF ENCINITAS — DEVELOPMENT SERVICES DEPARTMENT DRAWING N0. EROSION CONTROL PLAN FOR: A.P.N. #258- 202 -23, 24, AND 25 F STREET PROJECT, LLC 14641 - G 66, 76, AND 84 F STREET 0 ENCINITAS, CA 92024 LDEV- 012763 -2020 U PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 4 OF 8 DESIGN BUILD PLANS: I� 3 I 3 I _ EX_7 �EX=1 Know what's b @IOW. Cal I before you dig. DIG ALERT!! TWO WORKING DAYS BEFORE DIG ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT Et GENERAL CONTRACTOR SHALL LOCATE Et POTHOLE (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL CONSTRUCTION BEGINS. f T / I s STATE OF CALIFORNIA A B C D 'TC =,59.30 E F G H J K L M N 0 LAMD60. F PROPERTY LINE / 3 9 S- E= 154.30 / so ' / Fs= TW@FS =15 DEPARTMENT OF INDUSTRIAL RELATIONS /I r, \\ / 'n' I I =157.9° // - s =57.zo BWC�FS =15f DIVISION OF OCCUPATIONAL SAFETY AND HEALTH - \�� v F5= 158.60 158.00 -� w p FL= 156.04 F P EX= 156.09 TRENCH/ EXCAVATION PERMIT N0.- - - - - - - - - - - _ 8 - I - / 3 I f TG= A 1 PROPERTY LINEI - - - - _ I �' °���ruUT TO / GRFMS�. rA DRAIN (TYPICAL) / \\ LEGEND �� 50.50 _ TWC�DFS =15 7 I um UMp I I = 148.50 ' I =151. 'IG 'Y50 I rET BW®EX =iS . / / \\ T.O.W. = TOP OF SOLDIER BEAM WALL WIDEx 6" � as _ DEEP � r _ P S -1s I wr I o �a<<�� s.so 1 o - / PROPOSED DUPLEX PROPOSED DUPLEX t' I° B �S 1 B.O.W. - BOTTOM OF SOLDIER BEAM WALL PROPOSED SINGLE FAMILY RESIDENCE ss.so 6 NF(' F 755.14 i BY OTHERS = WORK OUTSIDE SHORING SCOPE rF- 56 �Vwl I I I I I I I I I I � ) E= 155_19 F�14538 j ci )' 2° GRATE 5780., -- �COND FE- (P) = PROPOSED / j 769. // 5 UNIT 1 UNIT 2 �� UNIT 3 { UNIT 4 TEMPORARY SLOPE sr FF_758 000 1 E 1ss 20 / I (E) 2 -STORY RESIDENCE / \' (BY OTHERS TYP.) 'AD =157 s° I 2% �I�'� = I (E) = EXISTING 3 s= lss.so 4 - - - - - - - - - -� �I �s= 155.14 p 5 PROPOSED TEMPORARY SHORING - / 1 / I = 4.82 / TWOF 4 TYPICAL SEE SHEET SH6) 5731 / v % / Ij ' i ' I i 3 \ I PROPOSED IMPROVEMENTS ( III f ✓ AREA DRAIN / 157.46 LONG / X-152.7 rc=14s ,$„ G I /I -= 1ss.8s BR RETEN PION B 6 DEEP I /i I / \ IE =143.225 TE - z _ .SIN � + 1 � FS EA -g SF •:., / I � \ / 2 6 �@FS= ,s0.05 IMPROVEMENT SYMBOL I- - I 7 3 t - - a.-� - - - - -I 7G_r A - - - _ �'E� a . F• .. 3 \ + j, -- LU I I _41 �F :',�,/ \ 78" G _ �I�g7E < ° •% / -'` ' I h TEMPORARY SOLDIER BEAM I TW , . I _SUMP RP>l� I � BUMF I n � II �: � RE SD441N +/ 2 - - - - - - - - / is6.7s 156.50 se /venFS =7so.� !� x =, 9 w � - _ s I I I I 1 / TEMPORARY TIMBER LAGGING = TG= 151.21 TG -151 2 2.25' WIDE 76.3' LONG / FS= 157.50 a FL =154: 2 III II III 3.2 + �� - _ AR RAETEN TI N BASIN / r^ .njh i--- - - - -00 H5= 147.15 ° nL +"-'-'+ \ FS=1 .62 FS= 151.62 37 SF DS / I - EX =154.3 �/♦ S -1; v s'• 7W _ _ 1 AREA DRAIN FLU' MUM 80 > + +u� 2.5' WI z LO TG= 157.40 GRATE - Z m m I'7 \ BIORET -0016.3 L G S� IE= 156.57 157.40 / 2. A N C _ 1 AREA F BASIN LEANGU7 / �s - m IE- 156.20 25' TIDE RI M- 156.00 ° / / / TC= XX J' AREA r NTI k 16.3'1 LoN( �!� �� r - IE =1ss.4 / "LL s" PVC, s =19, z6% a -Po SOLDIER BEAM COUNT _ OY6V BAS ni J FL O J // � FS =15 �00 I F 1 I TW= 156.00 � o+ ^' TEMPORARY SLOPE + nlr� II 1z° RATE / rW�FS- 158.00 111 I,4 IE =SZ.so _ 12" cRA rE - T`is7.00 / rc 2,50 - L _ PROPOSED BIO- RETENTION rC= 152.30 \ - IE 163515° (BY OTHERS, TYP.) : =,ss.B =15482 / TWC�FS =156.00 ' / I I TC= 154.9 / = 149.92 i� /� - TWOoFS =158.00 ui / rW--FS= 749.80 P F: `. io0.02 FS= / \ - FS =153.7 BWpFS= 155.38 ' IFS= 754.40 / BASING (SEE CIVIL DWG.) W Ti 8W'FS=155.75 / / - �1�= 154.44 /' DETAIL /SECTION CALLOUTS X�/ u r F 149.5 S=15Q_0� 5=751 10�� 0, 0 F =153.79 FS o / W / � � - � JaoA / �� FS FS51� // FLF= 153.94 � / SH/� X147.6 NS 19 0 1 7.65 2 / PROPOSED LATERALS \ \ \ F - 155.37 / / - / II JNW� / FS =154.6F mmrA / (SEE CIVIL DRAWINGS) \ / \ \ \ - / RIGHT -OF -WAY °3- FS=, F st w�F, \ _ rw =1s3.8 /"y PRIOR FS� - - - PER DO =150.0 \ \ wy \ \ \ \ �/ 5 =155. �` -� �.' P DEDICATION - a149.5ki_ FS= 'x..04 °Y\ TW =151 53 jj��� \� =15�4� / \ \ FS-154 22 o W= 754.75 - >'i ,-x..(.;71`. h-rc " .i -0495299 ? r. �„ .,, 154.75 ., FS_h 49.42 / \ \ - / F -152- �V _ � 57 EX= 153.99 i I � \ \ - - -- L/ 3x12 DF #2 TIMBER LAGGING PROPOSED SIDEWALK ��g� � � , � . , � ,-'� I � _ - w' i9 , .n 1.7 �/' \ A, _ - �� FS =15410 \ (SEE CIVIL DRAWINGS) - �,r PROPOSED LATERALS sC `,� I- - v 54` (SEE CIVIL DRAWINGS) FALL_ �.�! " EX =153.98 L- _ - �C_ FL= TC =154. O TC= 155.00 E I 3.95 TC =149 C =149.8 so. a EXS X51.85 / rC= 152.58 / rC=153.30 87 80 TC= 155.00 EX= 154.93 X=15+147 77 FS- 154.50 \ / EX= 148.41 , EX= 148.91 EX = 14941 - FS =75i - ' -- -- FL= 15.;. - «// EX =7 JO FS= 154.30 \ / FL= 749.27 FL= 149.64 EX =750.1 _. - __ _ FL= 754.50 EX =754. EX =154.63 ----- - - - - -- G/ G G G/ G- L- G G/ G G � G- G C G G G G G G G ho EX= 149.7x / / H.P. EAST ' F' STR E E EX= 6p X- 54.62 , = 142.33 IE=�2.82 / IEy{44.1 I / RIM = 153.77 C RIM 149.73 I S TR E E \ FL= 12.00 \\ v Jam\ 7Q9 \ 7sO 7s7 sue\ 7S�\ FL- I / \ 145.79 W \ W W W w W 7 W W / W W W W W \ W W W W W v / - - - - -J I I / / / W I / O� oi STRUCTURAL REVIEW PERFORMED BY ESGIL, A SAFEBUILT COMPANY, AS PLAN CHECK 10 5 0 10 20 2020- 282 DATED MARCH 3 12020 SCALE: 1" = 10' SHORING DESIGN GROUP „F ow 619 - 561 -3510 ���P 7727 CAMINITO LILIANA o = _____ _ _____ SAN DIEGO, CA 92129, (760)586 -8121 CV CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. SRJ SRJ SCE j CITY OF ENCINITAS VERTICAL CONTROL STATION INT. DATE A.P.N. GRADING PLAN FOR: 258 - 202 -23, 24, AND 25 "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED # w DISC IN TOP OF CURB EAST SIDE OF VULCAN. PUBLIC WORKS S���N� �„� �' F STREET PROJECT LLC F- DATE: 14641- G Q ELEVATION = 92.004' PLANNING 66, 76, AND 84 F STREET DATUM = NAVD 88 STEVEN R. JONES DATE STEVE NOWAK EDWARD J. WMMER REVIEWER R.C.E. N0. ROY REED 913012020 17/30/0000 ENCINITAS, CA 92024 LDEV- 012763 -2020 -i i i I SENIOR ENGINEER DATE INSPECTOR EXP. 3 -31 -21 DATE DATE PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 5 OF 8 / I� 3 I 3 I _ EX_7 �EX=1 Know what's b @IOW. Cal I before you dig. DIG ALERT!! TWO WORKING DAYS BEFORE DIG ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT Et GENERAL CONTRACTOR SHALL LOCATE Et POTHOLE (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL CONSTRUCTION BEGINS. f T / I s STATE OF CALIFORNIA A B C D 'TC =,59.30 E F G H J K L M N 0 LAMD60. F PROPERTY LINE / 3 9 S- E= 154.30 / so ' / Fs= TW@FS =15 DEPARTMENT OF INDUSTRIAL RELATIONS /I r, \\ / 'n' I I =157.9° // - s =57.zo BWC�FS =15f DIVISION OF OCCUPATIONAL SAFETY AND HEALTH - \�� v F5= 158.60 158.00 -� w p FL= 156.04 F P EX= 156.09 TRENCH/ EXCAVATION PERMIT N0.- - - - - - - - - - - _ 8 - I - / 3 I f TG= A 1 PROPERTY LINEI - - - - _ I �' °���ruUT TO / GRFMS�. rA DRAIN (TYPICAL) / \\ LEGEND �� 50.50 _ TWC�DFS =15 7 I um UMp I I = 148.50 ' I =151. 'IG 'Y50 I rET BW®EX =iS . / / \\ T.O.W. = TOP OF SOLDIER BEAM WALL WIDEx 6" � as _ DEEP � r _ P S -1s I wr I o �a<<�� s.so 1 o - / PROPOSED DUPLEX PROPOSED DUPLEX t' I° B �S 1 B.O.W. - BOTTOM OF SOLDIER BEAM WALL PROPOSED SINGLE FAMILY RESIDENCE ss.so 6 NF(' F 755.14 i BY OTHERS = WORK OUTSIDE SHORING SCOPE rF- 56 �Vwl I I I I I I I I I I � ) E= 155_19 F�14538 j ci )' 2° GRATE 5780., -- �COND FE- (P) = PROPOSED / j 769. // 5 UNIT 1 UNIT 2 �� UNIT 3 { UNIT 4 TEMPORARY SLOPE sr FF_758 000 1 E 1ss 20 / I (E) 2 -STORY RESIDENCE / \' (BY OTHERS TYP.) 'AD =157 s° I 2% �I�'� = I (E) = EXISTING 3 s= lss.so 4 - - - - - - - - - -� �I �s= 155.14 p 5 PROPOSED TEMPORARY SHORING - / 1 / I = 4.82 / TWOF 4 TYPICAL SEE SHEET SH6) 5731 / v % / Ij ' i ' I i 3 \ I PROPOSED IMPROVEMENTS ( III f ✓ AREA DRAIN / 157.46 LONG / X-152.7 rc=14s ,$„ G I /I -= 1ss.8s BR RETEN PION B 6 DEEP I /i I / \ IE =143.225 TE - z _ .SIN � + 1 � FS EA -g SF •:., / I � \ / 2 6 �@FS= ,s0.05 IMPROVEMENT SYMBOL I- - I 7 3 t - - a.-� - - - - -I 7G_r A - - - _ �'E� a . F• .. 3 \ + j, -- LU I I _41 �F :',�,/ \ 78" G _ �I�g7E < ° •% / -'` ' I h TEMPORARY SOLDIER BEAM I TW , . I _SUMP RP>l� I � BUMF I n � II �: � RE SD441N +/ 2 - - - - - - - - / is6.7s 156.50 se /venFS =7so.� !� x =, 9 w � - _ s I I I I 1 / TEMPORARY TIMBER LAGGING = TG= 151.21 TG -151 2 2.25' WIDE 76.3' LONG / FS= 157.50 a FL =154: 2 III II III 3.2 + �� - _ AR RAETEN TI N BASIN / r^ .njh i--- - - - -00 H5= 147.15 ° nL +"-'-'+ \ FS=1 .62 FS= 151.62 37 SF DS / I - EX =154.3 �/♦ S -1; v s'• 7W _ _ 1 AREA DRAIN FLU' MUM 80 > + +u� 2.5' WI z LO TG= 157.40 GRATE - Z m m I'7 \ BIORET -0016.3 L G S� IE= 156.57 157.40 / 2. A N C _ 1 AREA F BASIN LEANGU7 / �s - m IE- 156.20 25' TIDE RI M- 156.00 ° / / / TC= XX J' AREA r NTI k 16.3'1 LoN( �!� �� r - IE =1ss.4 / "LL s" PVC, s =19, z6% a -Po SOLDIER BEAM COUNT _ OY6V BAS ni J FL O J // � FS =15 �00 I F 1 I TW= 156.00 � o+ ^' TEMPORARY SLOPE + nlr� II 1z° RATE / rW�FS- 158.00 111 I,4 IE =SZ.so _ 12" cRA rE - T`is7.00 / rc 2,50 - L _ PROPOSED BIO- RETENTION rC= 152.30 \ - IE 163515° (BY OTHERS, TYP.) : =,ss.B =15482 / TWC�FS =156.00 ' / I I TC= 154.9 / = 149.92 i� /� - TWOoFS =158.00 ui / rW--FS= 749.80 P F: `. io0.02 FS= / \ - FS =153.7 BWpFS= 155.38 ' IFS= 754.40 / BASING (SEE CIVIL DWG.) W Ti 8W'FS=155.75 / / - �1�= 154.44 /' DETAIL /SECTION CALLOUTS X�/ u r F 149.5 S=15Q_0� 5=751 10�� 0, 0 F =153.79 FS o / W / � � - � JaoA / �� FS FS51� // FLF= 153.94 � / SH/� X147.6 NS 19 0 1 7.65 2 / PROPOSED LATERALS \ \ \ F - 155.37 / / - / II JNW� / FS =154.6F mmrA / (SEE CIVIL DRAWINGS) \ / \ \ \ - / RIGHT -OF -WAY °3- FS=, F st w�F, \ _ rw =1s3.8 /"y PRIOR FS� - - - PER DO =150.0 \ \ wy \ \ \ \ �/ 5 =155. �` -� �.' P DEDICATION - a149.5ki_ FS= 'x..04 °Y\ TW =151 53 jj��� \� =15�4� / \ \ FS-154 22 o W= 754.75 - >'i ,-x..(.;71`. h-rc " .i -0495299 ? r. �„ .,, 154.75 ., FS_h 49.42 / \ \ - / F -152- �V _ � 57 EX= 153.99 i I � \ \ - - -- L/ 3x12 DF #2 TIMBER LAGGING PROPOSED SIDEWALK ��g� � � , � . , � ,-'� I � _ - w' i9 , .n 1.7 �/' \ A, _ - �� FS =15410 \ (SEE CIVIL DRAWINGS) - �,r PROPOSED LATERALS sC `,� I- - v 54` (SEE CIVIL DRAWINGS) FALL_ �.�! " EX =153.98 L- _ - �C_ FL= TC =154. O TC= 155.00 E I 3.95 TC =149 C =149.8 so. a EXS X51.85 / rC= 152.58 / rC=153.30 87 80 TC= 155.00 EX= 154.93 X=15+147 77 FS- 154.50 \ / EX= 148.41 , EX= 148.91 EX = 14941 - FS =75i - ' -- -- FL= 15.;. - «// EX =7 JO FS= 154.30 \ / FL= 749.27 FL= 149.64 EX =750.1 _. - __ _ FL= 754.50 EX =754. EX =154.63 ----- - - - - -- G/ G G G/ G- L- G G/ G G � G- G C G G G G G G G ho EX= 149.7x / / H.P. EAST ' F' STR E E EX= 6p X- 54.62 , = 142.33 IE=�2.82 / IEy{44.1 I / RIM = 153.77 C RIM 149.73 I S TR E E \ FL= 12.00 \\ v Jam\ 7Q9 \ 7sO 7s7 sue\ 7S�\ FL- I / \ 145.79 W \ W W W w W 7 W W / W W W W W \ W W W W W v / - - - - -J I I / / / W I / O� oi STRUCTURAL REVIEW PERFORMED BY ESGIL, A SAFEBUILT COMPANY, AS PLAN CHECK 10 5 0 10 20 2020- 282 DATED MARCH 3 12020 SCALE: 1" = 10' SHORING DESIGN GROUP „F ow 619 - 561 -3510 ���P 7727 CAMINITO LILIANA o = _____ _ _____ SAN DIEGO, CA 92129, (760)586 -8121 CV CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. SRJ SRJ SCE j CITY OF ENCINITAS VERTICAL CONTROL STATION INT. DATE A.P.N. GRADING PLAN FOR: 258 - 202 -23, 24, AND 25 "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED # w DISC IN TOP OF CURB EAST SIDE OF VULCAN. PUBLIC WORKS S���N� �„� �' F STREET PROJECT LLC F- DATE: 14641- G Q ELEVATION = 92.004' PLANNING 66, 76, AND 84 F STREET DATUM = NAVD 88 STEVEN R. JONES DATE STEVE NOWAK EDWARD J. WMMER REVIEWER R.C.E. N0. ROY REED 913012020 17/30/0000 ENCINITAS, CA 92024 LDEV- 012763 -2020 -i i i I SENIOR ENGINEER DATE INSPECTOR EXP. 3 -31 -21 DATE DATE PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 5 OF 8 0 CV O cV n w Q O J 160.00' 150.00' 140.00' NOTES: 1. SEE SOLDIER BEAM SCHEDULE ON SHEET SH7 FOR SHORING ATTRIBUTES. 2. POTHOLE /FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. 3. TEMPORARY SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING Et PROPOSED FEATURES, AS PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL CONTROL Et COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY VARIATIONS TO THE SHORING ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK. ri I= J >J W W. /culn \ n Cl ' �s U) 0 W \ DESIGN BUILD PLANS: PROPOSED LATERALS (SEE CIVIL DRAWINGS) F\ I _ , SB #2 SB #3 SB #4 SB #5 SB #6 SB #7 SB #8 PROFILE - LOOKING SOUTHWEST vp �y�Qr1 y SCALE: 1" = 16/3 Q 4 8 16 SCALE: 1 " =16V' 160.00' .W. = 154.00' .W. = 150.00' 150.00' LEGEND: T.O.W. = TOP OF WALL B.O.W. = BOTTOM OF WALL 1� PROPERTY LINE DESIGNATES 3x12 PRESSURE TREATED TIMBER LAGGING 140.00' SHORING DESIGN GROUP 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586 -8121 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS —BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS — DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. SRJ SRJ SCE CITY OF ENCINITAS VERTICAL CONTROL STATION "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS DISC IN TOP OF CURB EAST SIDE OF VULCAN. ELEVATION = 92.004' DATUM = NAVD 88 STEVEN R. JONES DATE SENIOR ENGINEER DATE INT. DATE PLANS PREPARED UNDER THE SUPERVISION OF DATE: R.C.E. N0. ROY REED EXP. 3 -31 -21 RECOMMENDED APPROVED St2NPiNoAv k/ � d n. w a STEVE NOWAK EDWARD J. WIMMER 913012020 T13010000 DATE DATE A.P.N. GRADING PLAN FOR: 258- 202 -23, 24, AND 25 # F STREET PROJECT LLC 66 76 AND 84 F STREET > ENCINITAS, CA 92024 PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 14641- G LDEV- 012763 -2020 PUBLIC WORKS PLANNING REVIEWER INSPECTOR I I I SHEET 6 OF 8 O N O N w Q O J ch GENERAL NOTES 1. CONSTRUCTION PLANS AND CALCULATIONS CONFORM TO THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODE. 2. TEMPORARY SHORING CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE OF CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL - OSHA). 3. HEAVY CONSTRUCTION LOADS SUCH AS CRANES, CONCRETE TRUCKS OR OTHER LOAD SURCHARGES NOT IDENTIFIED IN THE "DESIGN CRITERIA ", WILL REQUIRE ADDITIONAL ANALYSIS Et FURTHER RECOMMENDATIONS. NOTIFY THE SHORING Et SOILS ENGINEER. 4. ALL TEMPORARY SHORING ELEMENTS DEPICTED WITHIN THESE DRAWINGS ARE LIMITED TO A MAXIMUM SERVICE LIFE OF ONE (1) YEAR. AT THE END OF THE CONSTRUCTION PERIOD, THE EXISTING OR NEW STRUCTURES SHALL NOT RELY ON THE TEMPORARY SHORING FOR SUPPORT IN ANYWAY. 5. AN UNDERGROUND SERVICE ALERT MUST BE OBTAINED 2 DAYS BEFORE COMMENCING ANY EXCAVATION. 6. THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS DURING CONSTRUCTION. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL INSPECTION SERVICES, TESTING Et NOTIFICATIONS. 8. ALL PERMITS SHALL BE PROCURED AND PAID FOR BY THE OWNER OR GENERAL CONTRACTOR. 9. ALL MONITORING PROVIDED IN THESE PLANS HEREIN, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. TEMPORARY SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING Et PROPOSED FEATURES, AS PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL CONTROL Et COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY VARIATIONS TO THE ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK. 11. THE GENERAL CONTRACTOR OR OWNER SHALL LOCATE ALL EXISTING UTILITIES AND STRUCTURES PRIOR TO EXCAVATION AND THE INSTALLATION OF SHORING. 12. THE GEOTECHNICAL ENGINEER OF RECORD SHALL REVIEW Et VERIFY THAT THE PROPOSED TEMPORARY SHORING, CONFORMS TO THE SPECIFICATIONS OF THE APPROVED SOILS REPORT. 13. THE GENERAL CONTRACTOR SHALL CONFIRM THAT THE PROPOSED SHORING DOES NOT CONFLICT WITH FUTURE IMPROVEMENTS PRIOR TO INSTALLATION. 14. THE GENERAL CONTRACTOR SHALL PROVIDE MEANS TO PREVENT SURFACE WATER FROM ENTERING THE EXCAVATION OVER THE TOP OF SHORING BULKHEAD. 15. INSTALLATION OF SHORING AND EXCAVATION SHALL BE PERFORMED UNDER CONTINUOUS OBSERVATION AND APPROVAL OF THE GEOTECHNICAL ENGINEER AND AUTHORITY HAVING JURISDICTION. 16. ALTERNATIVE SHAPES, MATERIAL AND DETAILS CANNOT BE USED UNLESS REVIEWED AND APPROVED BY THE SHORING ENGINEER. 17. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFY CONDITIONS AT THE JOB SITE AND TO CROSS -CHECK DETAILS AND DIMENSIONS WITHIN THE SHORING PLANS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER PERTINENT DRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. 18. ALL GRADING Et EXCAVATIONS PERFORMED FOR THE PROPOSED TEMPORARY SHORING AND /OR PROPOSED STRUCTURE, IS OUTSIDE THE SCOPE OF SERVICES PROVIDED HEREIN. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONDUCTING SITE EARTHWORK IN CONFORMANCE WITH CAL -OSHA Et GEOTECHNICAL RECOMMENDATIONS. SHORING INSTALLATION PROCEDURE 1. FIELD SURVEY DRILL HOLES Et SHORING ALIGNMENT ACCORDING TO WALL DIMENSIONS Et DATA SHOWN OR AS APPROVED BY THE SHORING ENGINEER. 2. DRILL VERTICAL SHAFTS TO THE EMBEDMENT DEPTH AND DIAMETERS SHOWN. ALLOWABLE PLACEMENT TOLERANCE SHALL BE 2" IN OR 2" OUT OR AS OTHERWISE AUTHORIZED BY THE SHORING ENGINEER. 3. INSTALL SOLDIER BEAMS ACCORDING TO THE DETAILS Et SPECIFICATIONS SHOWN IN PLAN. IF NECESSARY, CASING OR OTHER METHODS SHALL BE USED TO PREVENT LOSS OF GROUND OR COLLAPSE OF THE HOLE. 4. START EXCAVATION AFTER CONCRETE HAS CURED FOR A MINIMUM OF (3) THREE DAYS. 5. INSTALL LAGGING BETWEEN INSTALLED SOLDIER BEAMS IN LIFTS NO GREATER THAN 5' -0" OR AS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. 6. BACKFILL ALL VOIDS BEHIND LAGGING WITH COMPACTED SOIL OR LEAN CONCRETE AS SPECIFIED IN THE DETAILS HEREIN. 7. REPEAT STEPS 5 -6 UNTIL BOTTOM OF EXCAVATION IS REACHED. 8. ALL EXCAVATIONS SHALL BE LAGGED AND BACKFILLED BY THE END OF EACH WORKDAY. NO EXCAVATIONS SHALL BE LEFT EXPOSED OR WITHOUT BACKFILL. DESIGN BUILD PLANS: MATERIAL SPECIFICATIONS STRUCTURAL STEEL 1. STRUCTURAL STEEL (WIDE FLANGES) SHALL CONFORM TO THE REQUIREMENTS ASTM A -572 OR ASTM A -992 (GRADE 50). 2. MISCELLANEOUS STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A -36, ASTM, A -572 (GRADE 50) OR ASTM A -992. 3. TRENCH PLATES (LAGGING) SHALL CONFORM TO THE REQUIREMENTS FO ASTM A -36. 4. WIRE ROPE (GUARDRAIL): SHALL HAVE A MINIMUM BREAKING STRENGTH OF 13,500LBS. STRUCTURAL Et LEAN CONCRETE A. STRUCTURAL CONCRETE: 1. STRUCTURAL CONCRETE (DRILL SHAFT TOE BACKFILL) SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,50OPS1 AT 28 -DAYS. 2. CONCRETE MIX SHALL BE IN ACCORDANCE WITH 2O16CBC Et ACI 318 TO MEET THE FOLLOWING: A. MAXIMUM 1 -INCH HARDROCK CONCRETE CONFORMING TO ASTM C -33. B. TYPE II NEAT PORTLAND CEMENT CONFORMING TO ASTM C -150. C. SLUMP NO GREATER THAN 5- INCHES. B. LEAN CONCRETE (SLURRY) 1. LEAN SAND SLURRY MIX SHALL CONTAIN A MINIMUM OF 1.5 SACKS TYPE II CEMENT PER CUBIC YARD. 1. TIMBER LAGGING SHALL BE ROUGH SAWN DOUGLAS FIR LARCH NO. 2 OR BETTER. 2. TIMBER LAGGING SHALL BE PRESSURE TREATED FOR GROUND CONTACT IN ACCORDANCE WITH AWPA U1 USE CATEGORY 4A. WELDING 1. ELECTRIC ARC WELDING PERFORMED BY QUALIFIED WELDERS USING E70XX ELECTRODES OR CONTIUOUS WIRE FEED. 2. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. MONITORING 1. MONITORING SHALL BE ESTABLISHED AT THE TOP OF SOLDIER BEAMS SELECTED BY THE ONSITE GEOTECHNCIAL REPRESENTATIVE AND AT INTERVALS ALONG THE WALL AS CONSIDERED APPROPRIATE. 2. THE GENERAL CONTRACTOR SHALL PERFORM A PRECONSTRUCTION SURVEY INCLUDING PHOTOGRAPHS Et VIDEO OF THE EXISTING SITE CONDITIONS. BASELINE SURVEY DATA TO BE SUBMITTED TO CITY LAND SURVEYOR. 3. MONITORING SHALL BE PERFORMED AFTER ROUGH GRADING, ANY SIGNIFICANT STORM OR SEISMIC EVENT AND AT THE TERMINUS OF THE PROJECT. FINAL MONITORING REPORT SHALL BE SUBMITTED TO CITY LAND SURVEYOR PRIOR TO OCCUPANCY. 4. MAXIMUM THEORETICAL SOLDIER BEAM DEFLECTION IS 1 -INCH. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) EXCEEDS THIS LIMIT, ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED AND INVESTIGATED BY THE SHORING ENGINEER FOR FURTHER ACTIONS (AS NECESSARY). STATEMENT OF SPECIAL INSPECTIONS VERIFICATION AND INSPECTION CONTINOUS PERIODIC CBC REFERENCE 1. Verify use of required design mix X 1904.2.2 2. Inspection of concrete placement for X proper application techniques. 3. Material verification of structural steel a. For structural steel, identification X markings to conform to AISC 360. b. Manufacturer's report X 4. Inspection of welding a. Multipass fillet welds X 2303.1.8.1 5. Material identification of timber a. Identification of preservative X VERIFICATION AND INSPECTION ITEMS (OTHER) 6. Observe drilling operations and maintain complete and accurate X records for each element. 7. Verify placement locations and plumbness, confirm element diameters, lengths, embedment into X bedrock (if applicable). Record concrete and grout values. 8. Verify excavations are extended to the proper depth. X SPECIAL INSPECTION REPORT PREPARED BY: DATED . ON FILE WITH ENGINEERING DIVISION. DESIGN CRITERIA 1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED IN THE FOLLOWING GEOTECHNICAL REPORTS: A. REPORT OF PRELIMINARY GEOTECHNICAL INVESTIGATION F STREET RESIDENTIAL DEVELOPMENT 66, 76, AND 84 F STREET ENCINITAS, CALIFORNIA PREPARED BY: CHRISTIAN WHEELER, DATED JANUARY 30, 2019. 2. SOIL DESIGN PRESSURES A. PASSIVE EARTH PRESSURE = 425PCF B. ACTIVE EARTH PRESSURE = 30PSF /FT (CANTILEVERED) SHORING DESIGN GROUP „F ow 619 - 561 -3510 ���P 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586 -8121 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. SRJ SRJ SCE CITY OF ENCINITAS VERTICAL CONTROL STATION INT. DATE A.P.N. GRADING PLAN FOR: 258 - 202 -23, 24, AND 25 "ENC -32" POINT NO. 1032. A 2" MONUMNET BRASS PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED # DISC IN TOP OF CURB EAST SIDE OF VULCAN. PUBLIC WORKS St-ewe, Nowak � � F STREET PROJECT LLC ELEVATION = 92.004' PLANNING DATE: 66, 76, AND 84 F STREET 14641 - G DATUM = NAVD 88 STEVEN R. JONES DATE R NOWAK EDWARD J. WIMMER ROY REED REVIEWER .C.E. N0. 913012020 1713010000 ENCINITAS, CA 92024 LDEV- 012763 -2020 SENIOR ENGINEER DATE INSPECTOR EXP. 3 -31 -21 DATE DATE PLANNING CASE NO. MULT12940 -19; CDPNF2941 -19 & DR2942 -19 SHEET 8 OF 8 11