2017-13531 G (Plans)iTICTS9414INLIVAR00
OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48
HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN
ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE
OWNER TO KNOW WHERE HIS /HER PROPERTY LINE IS.
DRAINAGE NOTE
NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS
TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO
AN APPROVED DRAINAGE FACILITY.
UTILITY NOTE
ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND
GENERALNOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF
ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR
REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR
INSPECTION.
2. THE SOILS REPORT TITLED "PRELIMINARY GEOTECHNICAL INVESTIGATION PROPOSED SUBDIVISION
1375 NORTH VULCAN AVENUE (APN: 254 - 254- 12 -00) ENCINITAS, CALIFORNIA. CTE JOB NO. 10- 12763G"
DATED DECEMBER 4. 2015 SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL
BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID
REPORT.
3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY OR
EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS.
4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE
GRADING.
5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT
PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE
REPLACED OR REPAIRED TO CONDITION
EXISTING PRIOR TO GRADING.
6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS
DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL
ENGINEER OR A LICENSED LAND
SURVEYOR.
7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING
SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL
SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS.
8. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (1/2) MILE OF A STRUCTURE FOR HUMAN
OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON
SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS.
9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE - CONSTRUCTION MEETING HAS BEEN
HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS
ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE - CONSTRUCTION MEETING SHALL BE
SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633 -2770.
10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE
WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY
ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS
AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION.
11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL
GRADING APPROVAL ANDIOR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL
BE PROVIDED STATING: "THE GRADING UNDER PERMIT
NO. 13531 -G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED
GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT SHALL BE
FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING
OPERATION.
12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS
DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS
AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED
AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING
OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS
SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE
FOR THEIR INTENDED USE.
13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE
DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID
DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL
MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT
DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED.
14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE
MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS
TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL
GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN
COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS.
15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH
SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL
BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT
AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR
EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE
REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN
ACCORDANCE WITH THE GRADING ORDINANCE.
16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED
OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT
HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS.
APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY
ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL.
17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITYS URBAN
FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY
PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE
PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO
GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE
CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF
THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE
REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT
WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE
TREE REMOVAL.
CHANGE
/L.'T
r -•
EROSION CONTROL
1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT TONY CASSOLATO AT{ 619) 823 -_16o2
24 HOURS A DAY.
2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES
DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE
STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID
CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT.
3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE
ENGINEERING INSPECTOR.
4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO
THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL.
5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE
REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN
CIRCUMSTANCES WHICH MAY ARISE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO
PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE.
7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE
INCORPORATED HEREON.
8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF
SLOPE AT THE CONCLUSION OF EACH WORK DAY.
9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH
WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40
%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL.
STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP /IMP NOTES
1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS
SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS
PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM
DRAIN SYSTEM.
2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL
NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY.
3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP /IMP FACILITIES
AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE
FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITY
AND /OR THE TURF /LANDSCAPED AREAS.
4. NO DRAINS SHALL BE INSTALLED IN HANDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA
UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP/BMP-
5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE
ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE
IT TO AN ADEQUATE IMP /BMP.
6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED
WITHOUT A PERMIT FROM THE CITY.
7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY
REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED.
8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM
WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN
IMPERVIOUS, NON - COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE
ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM
SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE
DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE
AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN
AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES
THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A
CITY- APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER
SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE
REQUIRED FOR THIS STRUCTURE.
SAN DIEGUITO WATER DISTRICT NOTES:
1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE
STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC).
2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE
REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR
NON - EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS
PROJECT.
3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE
PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR
PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON
IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN
WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT.
4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND /OR ADJUST TO GRADE ANY
EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS
AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER
AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS,
THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE.
5. UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER SERVICES.
6. MINIMUM HORIZONTAL SEPARATION OF 10 -FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN
DIEGO GAS AND ELECTRIC VAULTS.
7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED
WAYS.
WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING.
8. CALIFORNIA STATE LAW ASSEMBLY BILL AB -1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN
THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN
COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS
PARTS.
9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED
WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC -17 OR WC -18.
Tl ■11 Vw
DESCRIPTION: #1004 STATION NAME: ENC -04
SET 2.5" CITY OF ENCINITAS BRASS DISC IN
IN DRAINAGE BOX INLET.
LOCATION: THE NORTHEAST CORNER OF THE
CITY OF ENCINITAS LEUCADIA OAKS PARK ON
THE WEST SIDE OF RAINTREE DRIVE,
ELEV: 67.639 DATUM: NAVD 88
STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES
CONCRETE WASHOUT
CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE
WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO,
PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL
POST A SIGN DESIGNATING THE WASHOUT LOCATION.
CONSTRUCTION SITE ACCESS
A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT
TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL
PANELS /PLATES.
CONSTRUCTION VEHICLES
A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES
PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE.
EROSION CONTROL
EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE
PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS,
ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX.
NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER.
DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL
PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES.
REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN
PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS
UNNECESSARILY; THEY HELP DECREASE EROSION.
TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR
EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST - GROWING ANNUAL AND PERENNIAL
GRASSES TO SHIELD AND BIND THE SOIL.
PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE.
WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED.
ON -SITE CONSTRUCTION MATERIAL STORAGE
STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL
STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY
CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES
KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC.
STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN
INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A
TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES.
TRAINING
CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR
WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE
AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM
SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES.
WASTE MANAGEMENT
CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION
MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE
CONVEYANCE SYSTEM IS STRICTLY PROHIBITED.
NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS /DIKES SHALL BE PLACED AROUND
ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS.
DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES
WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL.
MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND
CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED, NON - RECYCLABLE MATERIALS MUST BE TAKEN TO AN
APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS
MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO
ORDER DUMPSTERS CALL EDCO AT (760) 436 -4151.
POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE
SITE.
PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS, CONTRACTOR SHALL
PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS
SURFACES.
ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST
ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE
FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE
ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633 -2770.
NOTIFICATIONS
1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE
OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES
EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION,
FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK:
A. SEWERS LWD - (760)- 753 -0155
B. GAS & ELECTRIC - SDGE - (760)- 438 -6200
C. WATER - SAN DIEGUITO WATER DISTRICT -1- 800 - 227 -2600
D. TELEPHONE - SBC BELL - (760)- 489 -3411
E. CABLE TV - COX COMMUNICATIONS- (760)- 806 -9809 X -2233
2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT.
PHONE: (760)- 633 -2770.
3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633 -2770. ALL WORK
PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL.
IMPERVIOUS AREA
IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 2723 SOFT
IMPERVIOUS AREA FOR DRIVEWAY: 1634 SOFT
IMPERVIOUS AREA HOUSE AND PATIOS: 3136 SQFT
TOTAL NEW IMPERVIOUS AREA: 4775 SQFT
PLIBUC WORKS
SEWER PUBLIC SYSTEM APPROVAL "
_.
BY: LWD
�� DISTRICT •3 69
or
r^ ON -DATE ``
DEXTER WILSON
Firm . DATE
REV.
HORIZONTAL: N /A
LAWRENCE E. COLE
VERTICAL: N/A REVIEWER INSPECTOR FSENIOR ENGINEER
S KIC I�1 -f12 o . )/C IN I'v-,6 LAWRENCE E. COL
.0 -(Q 3.19 -[S
DATE SIGN u DATE
• i,
•A
.)
OWNER SITE ADDRESS
MBM GROUP LLC 1375 NORTH VULCAN AVENUE
MICHAEL CASSOLATO, MGR. ENCINITAS, CA 92024
576 CAMINO ELDORADO APN: 254 - 254 -12
ENCINITAS, CA 92024
PH. (619) 823 -3602
LEGAL DESCRIPTION
THE SOUTHERLY 66 FEET OF THE WESTERLY 115 FEET
OF LOT 5, BLOCK 3, SOUTH COAST PARK, IN THE CITY
OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA,
ACCORDING TO MAP THEREOF NO. 1776, FILED IN THE OFFICE
OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, o
JANUARY 11, 1924. cl
9
OWNER'S CERTIFICATE 2
I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR
GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL
GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF
THE SITE.
I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S
OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST
ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES,
DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING
OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY
ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES,
CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES
FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR
CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS
WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS.
SIGNATURE: ZvocAi M DATE:
MICHAEL CA SOLATO,
MBM GROUP LLC
576 CAMINO ELDORADO
ENCINITAS, CA 92024
PH. (619) 823 -3602
SOILS ENGINEER'S CERTIFICATE
1, DANIEL T. MATH, A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN
THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL
CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 12 -04 -2015 AND FOR
AN UPDATE ON . ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY
RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE
REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS
REPORT FOR THIS PROJECZ4AAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS.
SIGNED:
79Ti-EL T. MATH PROFESS /p�
GE NO.: 2665 ko� EL T. MgA��c
EXP. DATE: 12/31/18 win
GE No. 2665 �1
JOB #: 10- 127636 Exp. 12/31/18
CONSTRUCTION TESTING & ENGINEERING, INC, ST p C1 VIL ��
1441 MONTIEL ROAD, SUITE 115 F OF CAUFOR
ESCONDIDO, CA 92026
PH. (760) 746 -4955
STATEMENT OF ENGINEER OF WORK
THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH
THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE
ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE
RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER
CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY
THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS
NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE
PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS
OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS
THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY
INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER
AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND
ARISING OUT OF THE WORK PERFORMED BY� THE EEENGINEER.
SIGNATURE: - �L/' � DATE:
LAWRENCE E. COLE
LANDMARK ENGINEERING CORPORATION o PROFESS /p
3443 CAMINO DEL RIO SOUTH, STE 204
SAN DIEGO, CA 92108 �� y
PH. (619) 260 -0420 L
RCE 36292 EXPIRES: 6130118 No. 36292
Exo. 06/30/18
EARTHWORK DATA CIVIL �s
STEEPEST EXISTING NATURAL SLOPE ON -SITE = 17.3% qTF pF CAL�F�R
MAXIMUM VERTICAL DEPTH OF CUT = 5.7'
MAXIMUM VERTICAL DEPTH OF FILL = 2'
CUT = 592 C.Y. FILL = 0 C.Y.
iMP9R7F/EXPORT = 592 C.Y.
REMEDIAL= 101 C.Y.( 1_5' REMOVAL AND RECOMPACTION UNDER AND 5 'OUTSIDE OF BUILDING AREAS)
TOTAL AREA OF LAND DISTURBANCE 9254 SQ FT
1 LANDMARK ENGINEERING
i
W,
SIGN DATE SIGN DATE
DATE_-/ � / -1 d DATE 7'19'Z016 I PLANNING CASE NO:
r
13531®
am
z
0
N
w O
N
w��
�0
zo
cn
w0 LL
w
ZJN
w
moo®
wog
a�zN
rn
°z "t
x
g�a
LA
n
N
T
O
1
N
V
:O
N
1�
1
t
r
i
s
Y
� ,4
\ \ 01 <ao V pp6 26 \ i :z � X . 66 63
9.42 5 J
/
( 6 \
\ (FL 59.09) S� PAR (66
C
\ � 79J �
\ 59.19 \ EGPS DV /z g�ppK MPP �Ao • (67.90)
64.43 '255 13 .90
'R
ED
0 \ (T8 59.40 0 4 _ , � (6 >4 (67.67 81 _ n
\ G�
(FL 59.15) 619 APB. 25 I 665 '% EDGE PD 9 �J,�? 67.93 �\ �(s82sJ
(5 =8) c \
�oJ ' / R�EX1S� • 36 ONED0 67\
f g 66.67 REM
\ EX UR FgNDE I r 10 BE (s> (6,>3 67.67 _
\ \ \ o
\ s a 67.31
a (67.41 rn 6
\s \ \ (Te 66.26 l PSPV\ 6�96� 480 PpDM
`J \
00, 59.07) / i� 64.54 EX \Sj �1R�M0\�ED (65.67) �W ls0 25 \ \P 7.40) I/
X60 0.2) i 6 �0 8
\ \ s2.is / \
\ ` F8
?59.0 �) s0 2.83 R \\� (64.93
es \
5 t gEE. XD. R P SPP
67 46 � 0 _(658.4 , 0 t s I
\
\ \ 5 I J m�`�. 'No qt r EDGE PC, _: .,,.. '\ 6 a 67.42 Z \
SDG
i
ca 1 ,?Ar�Af
9J A
• (58.10 ERS l2� +- '- 0.7>� �X\, .'.. $s � "� .c� F-'r
\\\ \ \PROP��� -��� 7'„ •� < $,� \\ \ FFg2.OS \
L ,,�
57.49 \ i �% e. , \ aoD
_(1761)
o \ \ \\ G '} A+Al�i+ o\ I `�'' •. \�a ' \\ FF \62.04 \ \ \ pROpOS� (\
67.44 t7 \
Z06 SDEN AND + } } \ \ sin F \3 %, �S � s 7 vo a' $ o
\ \+ +k + +k } }+ + 'F\ \��,F \ WSJ �jF6 `•Vg \\ \oi
\ \ k+ + }+ k_ �o cs /3e dl \ �1G S \ o d � '^ v
y s
FOR NEW STREET Jr + + A-
IMPROVEMENTS 89 ° si 4r.
SEE \ \ \ s+ + +, k kk + E } �� F J\ s \ �F6 ° d C`� ,�� `S
DWG. N0. 13531 -I \\ 57.90 }k } + + + + + .,< 8� �° ° \ N \ Q d 63 - FEN��
\ 7 \ } + + o �> FS61.72
*PRIVATE KEYSTONE RETAINING WALL
AND (2) SIEWALK UNDERDRAIN + ikWI3811+ + ON 3k a ° -\ d \ 2'` Q �p -r \ d ° d d
ENCROACHMENTS TO BE MAINTAINED + +ti "a + + + ° s "PVO ® 0. A y \0� °p� E`NP % % ) \ s N
+ + + ° rn �� 6.e -Ll ` �R \v 8 D ss 6464 (s )� FSP
BY HOMEOWNER PER ENCROACHMENT \ � .� N ° \ ON ss
MAINTENANCE AND REMOVAL \ + \ + +2 + } +. z,�6 �� - �, d_ Oil, FS6/ ,/PA/fE 6 C >o EX•
COVENANT DOC. N0.2A1$' Ol6ZnIZ \\ U +\ @���A� + d \ a �� dl 65.02 '4 66 ��6 8
DATED: \ }p pRE` p+t + } d 1 0 %.. 5 WER�IA E 6%89
25 A- `{ �.,kG} + +} .� . �D, v� \ .27' ° q F`10 PCK 64.59 J X• DN s4 8 $r ?�R
7, NI4 °5 SR
o \ \\ \ 'o, +Nab + OQlvFNj ° F �. \ . oIsR 64.54 P
P pE�`'D1D +
N \ _711 \ \ \ �- P k �\ K�SSOtdE
u) s
cn
(63.70)
•,�� ',� � ssO 633
NOTE: (sue U �� CP s 2
SEWER LATERALS CONSTRUCTED PER DWG. NO. 13531 -I I
\ �r:z c \
TRANS
G
J
\ o
A \ \ \ \ FL • 58.17
s
56.84
6 "X16" PCC FLUSH CURB
OR DEEPENED G -1 CURB
VOID FILLER - 1/8' TO 3/8" (NO. 8) ACKERSTONE(AQUA -VIA TRIO)
AGGREGATE IN VOIDS PERVIOUS PAVERS W/ MIN.
BEDDING COURSE - 2" THICK OF 3/8" VOID
1/8" TO 3/8' (NO. 8) AGGREGATE ' SEE SOILS ENGINEER'S
NOTE BELOW
CHOKER COURSE - 4" THICK OF <'
3/8' TO 1/2" (NO. 57) CRUSHED ROCK\
MIN. 6" THICK OF 3/4"
/ CRUSHED ROCK�6"
SOIL SUBGRADE
-ALL AGGREGATE MUST BE CLEAN /WASHED AND FREE OF FINES (SAND, SILT, ETC.)
-THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED
-EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE
o -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED
*SOILS ENGINEER'S NOTE:
IMPERVIOUS LINER OR FABRIC TO BE PLACED BETWEEN THE REAR YARD PAVER SECTION
AND THE BUILDING FOUNDATIONS ALONG THE VERTICAL LENGTH OF THE ENTIRE PAVER
SECTION. THE SUBGRADE SURFACE BELOW THE PAVER SECTION IS TO BE GRADED AT
MINIMUM OF 2% SLOPE AWAY FROM THE BUILDING FOUNDATION.
T Z O
o O
y �w
N ZOO
6 19 p O
Nj JOO
O
LEGEND
IMPROVEMENTS SYMBOL
PROPERTY LINE:
60)
EXISTING CONTOUR:
PROPOSED CONTOUR:
SETBACK LINE:
DIRECTION OF DRAINAGE
PRIVATE CATCH BASIN:
RETAINING WALL: PER WALL PLANS
SHEET 5
GRAVITY KEYSTONE RETAINING WALL:
PER WALL PLANS SHEET 6
AC BERM
6" CONC. CURB e
H
PCC CONCRETE D
°
NEW ASPHALT 3-AC/6 CLASS II BASE + + + + + ++
ASPHALT OVERLAY
ACKERSTONE (AQUA- VIA TRIO)
PERVIOUS PAVERS
DETAIL PER THIS SHEET
ABBREVIATIONS
EX. EXISTING
ASPH ASPHALT
a SETBACKS TELE TELEPHONE
ELEC ELECTRIC
(s8� 0 REQUIRED PROPOSED TRANS TRANSFORMER
FRONT YARD 20' FRONT YARD 20' FF FINISH FLOOR
\ SIDEYARD 5' SIDEYARD 5' GF GARAGE FLOOR
1, 1 r1l S:�I \ \
PLANTING
CpAD. 64.79 sass
POCKETS
s 3 \ A ppPST PARK K
PLANTING B\ ppK �\AP Np N115601 CONC. DRIWEWAYLf
�sJ POCKET D \Ng ApN. 254'25
DFF 65 24 F� 0 EX. ASPH
DRIVEWAY
-_ --
=1
2n R(1 =illl
M X ,
Sri �
FINISH GRADE >> SEE NOTE A
PAD 61.89
=II =11p
Iil =1111-
SECTION B -B
SCALE 1 " =5'
SECTION /A-/A
SCALE 1 " =5' Li
RETAINING WALLS LOCATED ON A PROPERTY LINE WILL
BE CAPABLE OF WITHSTANDING A SURCHARGE.
(TO THE SATISFACATION OF THE CITY ENGINEER)
FINISH GRADE
PAD 61.89
REAR YARD 15' REAR YARD 15' TW TOP OF WALL
BW BOTTOM OF WALL
LAND DISTURBANCE TG TOP OF GRATE
9254 SQ. FT. CB CATCH BASIN
FL FLOWLINE
FS FINISH SURFACE
RW R R
*11 ) r I _ - y I GRAVITO`fS � RA _
two 61..
NEW CURB, GUTTER
& SIDEWALK
FINISH SURFACE
AT 2% GRADE
25' It , R
PzD DBIICA im
1' `�� 5.86' 7.14' 5 3'
NSW RgMENT
4 AC 16 CLASS II o WATER METER (TYP.)
s BASE xs PER WAS WS -03
e
2 (0.8% _ %
FUTURE FINISH SURFACE NEW CURB GUTTER
AT 2% GRADE & SIDEWALk
NORTH VULCAN AVENUE FINISH SURFACE
STA 3 +55.47 AT 2% GRADE
SCALE 1 " =10'
WAN 11
00
0
N
�h BIORETENTION BASIN SHALL BE PLANTED
WITH ADEQUATE GROUNDCOVER OR TURF. 6.00' U
y EX. ASPH PLANTS THAT ARE NOT PRONE TO ROCK ENERGY TURF REINFORCEMENT MAT o
�- DRIVEWAY BLOCKING THE DRAINAGE FLOW MAY DISIPATOR IF APPLICABLETGX12CB o
- - -- ALSO BE PLANTED ON SIDE SLOPES 2 FREEBOARD
iii =ru- -- FL60.33
z
2" WALL 2A PER SDRSD C -03 `� �; � cc
SEE NOTE A SEE SHEET 5 FOR PROFILE
01
SECTION -C
SCALE 1 " =5'
NOTE A
INSTALL PREFABRICATED VERTICAL SHEET
DRAINS USING SINGLE SIDED SITEDRAIN
SHEET 180 SERIES (AMERICAN WICK DRAIN
CORP) OR APPROVED EQUAL. DRAIN IN A
STRIP ED DRAIN AT BASE PER SOILS REPORT.
No. 02M
ExP• 06/30/78
`Sy CIVIL L
OF CALv
2 -3 PVC 4"
I N Y:
z N c
TO CURB I I I =1 I I =1 I I III =1 I =1 I I� I I =1
"
WALL 2A PER SDRSD C -03
n
I1 =) I1 = � I I I=1) �I - I
]LI
SEE SHEET 5 FOR PROFILE
p
III = III = III =1�1
18' MIN, ENGINEERED SOIL
a=
a-r-�
,o,,,,o°°o°o° °,o °,;°
° °° ° ° ° ° °° ° ° ° ° °° °°
PER CITY OF ENCINITAS STANDA
"SEE NOTE BELOW"
o�
c)
41' a
2" MIN. 38' GRAVEL
z 0 c
uiw
��
z ui
z
1.33 4"
MIN. 3/4" CRUSHED ROCK
NOTE: OMIT SUBDRAIN PERF PIPE ON
Z 0 cc
w r
WALLS 2 AND 2A
cr a 6
¢o-
"ENGINEERED SOIL" LAYER SHALL BE MINIMUM 6" DEEP "SANDY
LOAM" SOIL MIX WITH NO
o n,
MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 50 -60% SAND, 20 -30% COMPOST OR
g n
HARDWOOD MULCH, AND 20 -30% TOP SOIL,
NOTE: NO FILTER FABRIC IS TO BE USED IN THIS SECTION.
BIORUMON BASIN
NO SCALE
AS -BUILT APPROVAL
I N Y:
DRAWN BY: CHECKED BY:
EN INE RI G DIVISION APPROVALS CITY OF ENCINITAS -
DEVELOPMENT SERVICES DEPARTMENT
- --
PLANS PREPARED UNDER SUPERVISION O'F. /
DATE: _�/�/�8
REVIE t� GRADING PLAN FOR:
�ii�tt✓L� / /e��rr�
CASS ®LATO RESIDENCES
415'7c ninoTU All 11 nAni Avcnsa oc
\ p1,1, uu
lE 5o a21 \ T8 59.4z
\ (FL 59.09) POR' �OOPS� PA fsBTS)
U1
SOVTH E -(ss)-
\ 59.16 \ LGPS G� g�00K MPp N0 EX \Sg�1REMCVEO \ (67.90)
5 -Z55'13 (67.60)
58.83 I f6,R7 67.81 \
\ \ G (8 59.75) 61 g0 PPN' 2 sss>/ 'EDGE PC Zg )^ rn 67.93 \\ (6825)
(5_ \ \\ un \ \\ \•, r,..� i6� RAVEL BAGS (ES6Q) �J6„
\ \ X � C� ) CE 7 EX \S8E MOVs 0 fs,� 9
\ Rg 2 HIGH 4TYP. 66.6, RE
\\ ? r? EX SE \ SEE DETAIL (64 >SJ EX LN NPSE I °' �0 s'oo >2j 36� �� 67.31
\ \ y 0s NP Y SC -8 SC 8 PR \IFWP -
\ 4 O P� WP ® \�`L C 167.41 s co
\ y ° \ \c R3 �61s�1 OR \VLF\ sA EX. 0 \SP\A i ' 's3
62.71 E FX. PSP 6�g6� C 80� » �M EX• 12 \\
WSJ \\ �� \ (FB 59.07) �X \rr�• �$ O Q 165.61 EX`�A
\ O ) , . -...
\\ (i8 59.21
g9,00 1 ,'"'"" - a\ 67.46 I
a
164.o
( g
� 62 FCK , , N 4 5 - 2�r2o� ' ° • 1 ":� v
58.40 �Fj m �� 3 67.42 \
\ \ \ \ \ (rc .SS 2�l EX 1 p \ \G& 0 ,1►1.0 r� ' \ 10.5 o
1 I- � � W � m , � 4 PVC a. �•-•` ,� � qs C9 `9i \ , -o -o �\ �, �
T r r \\ U� \\ Og \ Z fs > >2) \
\ (sa.10 I aso.7o Q ' J \E\ S60 F rrF
C6 G !s� CB A VF6 0 7r ",\ �
X�
\ i :
67.46 vG �c`1'o a? o\�
(57.61) \ \ \ Y5q.�! . 'o c,
- c \\ \ � -\ rn r `F62 \
+ +
T� ++
�Ti A
+ + m GO 6T B. \ c s d F
FOR NEW STREET \\\ \ + k + EX+ ��� 9 J '` Q .r ° s S \\ �F6 X89 ��. \ �) \ a FS &I
IMPROVEMENTS SEE \ 866 / + + �, + + + + as \ ,: o d , a a �\
DWG. NO. 13531 -1 \�7.90 ++ + - ++ + ++ + + \'`'4 �R ° -�' \\ r° � ad . a ° d
'O \ \\ \ \ + ++ + + d . FS61.72 o t a °) W S a ►. d
UN�`"2 •� 6 •5 .. 4 d a d/ \ W N a
6 °PV I AJ n OCiO`vV
� \ + ,• vin + + a � a � � � o. , - � � � \� � � ERNE
A- +Z + inr C) d �6a �A F$6 °tppll�" 65
��� \ ✓� 5 + + \\ p Dt Zst�� + ++ d \ 1.0% ✓ a 4E %y, J oKC. E�1�REE
2 X� "
\ \ '-�\+ A, k $ + + v\ B U Q �gPCK oo. 64.59 EX• 64 8 a
. r I
f �
T O
o �y
'700
3 O
�n0�
ti /.425 h ^ 1216 \ 61 O
9t11
4�^ y n
.6 ) 64.94 \ \ <6sJ PN
CONC 65>0� EX FS
L� �� ++ ++ a o g S X110 g9
✓ `� + + + 7 \� da O E 6�. PPS \0 A.
O \ �O A. + + ++
? \\ o;\ S® S s •r 64.58 EX PLANTING
wa�G sR i 0AC- POCKETS
� 64.79
6k 63 LOT 4 OOPS pP
TEMPORARY GRAVEL CONSTRUCTION i + 9 63.70) �o ?s OcK 3, S 10 �1� -6
ENTERANCE (OR APPROVED EQUAL) \ ° +�'j �-\' ®� 6 6 \ PLANTING a� MPP 35,01
SEE DETAIL THIS SHEET ( \- �'��� °s 332 ?sz POCKET 25q -2
® \ \ �d . 'nom 1) 6343 EX gl1 \LOS C PPN
y` < s� A v v\ FF 65.2
: � c 6z,2
Ex. 0 6 GRAVEL BAGS
\ ` G v \ 0, + m 2 HIGH (TYP.)
h�
\ 57.64 \ \ \ SgSO\ SEE DETAIL
�- \ \ "' \ fs2
\ N ¢ s) I SC -8 SC -8
\ s
f6.
\
FL • 58.17
6�S O
O \ \\ \ SB S O y�c' \ \ \ 8) n
f \ \ so
(57.60 \ �L >,
56.84
\ y o',
.°
\ FL 58.08
\ O \
\ 01 EX y
120Q
(TB 58.59 \
\ \\ (EI4S8.0 /(FL 57 \99) EX. BERM
CHANGE NO. DESCRIPTION APPRO D DATE BENCHMARK SCALE AS -BUILT APPROVAL
AS- -BULL DESCRIPTION: #1004 STATION NAME: ENC -04
SET 2.5" CITY OF ENCINITAS BRASS DISC IN l�1
IN DRAINAGE BOX INLET. HORIZONTAL: 1 " =20'
LOCATION: THE NORTHEAST CORNER OF THE LAwREAVCE E. CoGE
CITY OF ENCINITAS LEUCADIA OAKS PARK ON VERTICAL: 1 " =20'
THE WEST SIDE OF RAINTREE DRIVE. REVS Ew�R i>�SPEtruR SEnnta ENriu1
ELEV. 67.639 DATUM: NAVD 88 1 SW IcAa 1/Iq lb*
_ 5/`� 1' �1 • �G
No. 36292
E.P. 06 130118
\T CIV11 e
F C CAL \Fo
F+dlf�lk� e�y
6� !.. V::
DIVERS /ON RIDGE REQU IRED
WHERE GRADE EXCEEDS 2% 2 ,- OR GREATER
i
ROADWAY
FILTER FABRIC
SECTION A - A
\
NOTE: /
STRAW BALES, SANDBAGS, SPILLWAY USE SANDBAGS, STRAW BALES
OR CONTINUOUS BERM OF OR OTHER APPROVED METHODS
EQUIVELENT HEIGHT TO CHANNELIZE RUNOFF TO
8AS /N AS REQU IRED.
SUPPLY WATER TO WASH
WHEELS /F NECESSARY
FLOW FLOW
o
� o
A o A 2 " -3° (50 -75mm) o
COURSE AGGREGATE o 12' MIN.
MIN. 6" (150mm) TH K (-T, 6m)
DIVERSION RIDGE
50' (15m) MIN.
NOTES: PLAN
1. THE' ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT
TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT -OF -WAYS. THIS MAY
REQUIRE TOP DRESSING, REPAIR AND /OR CLEANOUT OF ANY MEASURES USED
TO TRAP SEDIMENT.
2. WHEN NECESSARY, WHEELS SHALL BE
CLEANED PRIOR TO ENTRANCE ONTO PUBLIC
RIGHT -OF -WAY.
J. WHEN WASHING IS REQUIRED, IT SHALL BE
DONE ON AN AREA STABLIZED WITH CRUSHED
STONE THAT DRAINS INTO AN APPROVED
SEDIMENT TRAP OR SEDIMENT BASIN.
TEMPORARY CONSTRUCTION
ENTRANCE
NO SCALE
EXTRA STRENGTH FILTER FABRIC
NEEDED WITHOUT WIRE' MESH SUPPORT
M LEGEND
.STEEL O
WOOD POST
ATTACH FILTER FABRIC
SECURELY TO UPSTREAM
DIRECTION
OF LOT DRAINAGE
SIDE OF POST
MATERIALS
& WASTE MANAGEMENT CONTROL BMPs
"' "'
1
CWG WITH s FVVEE
WM -1
MATERIAL DELIVERY & STORAGE
� /•BU E INCING WT� T
E T FE
WM -5
SOLID WASTE MANAGEMENT
STEEL OR WOOD POST
35" (1m) HM,H MAX.
WM -9
SANITARY WASTE MANAGEMENT
POND/NO HEIGHT POND /NG HEIGHT
WM -8
CONCRETE WASTE MANAGEMENT
N o ?Nmm
WM -6
HAZARDOUS WASTE MANAGEMENT
WX
f``O -" S 25--) B-(200mm
RAGE HT.
WM-
HAZARDOUS WASTE MANAGEMENT
I , v:
( mJ \ (' oo m)
4°r5' (100 X 150mmJ
TEMPORARY RUNOFF CONTROL BMPs
TRENCH WITH
BAGXF/LL COMPA TED
TMCH DBTAM DWALUUON API'HOUT TMCHING
FTC -1
STABILIZED CONSTRUCTION ENTRANCE
i°sarFENGESH41LBEP/ACmONSLOPE
CON70URS TO MAX /M/ZE PONDING EFFICIENCY.
SC -6 SC -8 GRAVEL OR SAND BAGS
2 /hSPECT AND REPNR FENCE AFTER EACH
STORM EVENT AND REAro SEDIMENT WHEN
NECESSARY .9 225mm MAXIMUM
RECOMMENDED S BE EAwT.
SC -1
SILT FENCE
3 REMOVED SEDIMENT SHALL BE DEPOSITED
To AN Aqv
SEDIMENT OFF SITE AND CAN BE PEERMANEMLY
FS-C---71
STREET SWEEPING
SILT FENCE DETAIL
NO SCALE
W
Z
Z
N
CONCRETE THE CONCRETE MUST COMPLY WITH ACI318
FOUNDATION: GENERAL NOTES 1. CEMENT SHALL CONFORM TO ASTM C150,TYPE II.
1. ALL FOUNDATION RECOMMENDATIONS SHALL COMPLY WITH THE CBC 2016 1. IN CASE OF CONFLICT, SPECIFIC NOTES AND DETAILS SHALL TAKE 2. AGGREGATES SHALL CONFORM TO ASTM C33 FOR HARD ROCK CONCRETE, AND TO
PRECEDENCE OVER THESE GENERAL NOTES AND STANDARD DETAILS. ASTM C330 FOR LIGHTWEIGHT CONCRETE. AGGREGATE SIZE SHALL BE 3 4
SECTION 2 SDRSD C -01 5' -4" '.
SDRSD C -01 (3' -8 ") / '
a 2. FOOTINGS EXCAVATIONS SHALL BE KEPT FREE FROM LOOSE MATERIAL AND 2• WHERE A DETAIL IS IDENTIFIED AS TYPICAL THE CONTRACTOR SHALL 3. READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C94.
STANDING WATER :PRIOR TO POURING CONCRETE, EXCAVATIONS SHALL BE APPLY THIS DETAIL TO EVERY LIKE SITUATION, WHETHER OR NOT THE ¢, APPROXIMATE DRY DENSITY SHALL BE 110 PCF FOR LIGHTWEIGHT CONCRETE
REFERENCE IS MADE IN EVERY INSTANCE.
°z CHECKED, AND 145 PCF FOR HARD ROCK CONCRETE. CONCRETE SHALL BE HARD ROCK.
66.83 3. SUBMIT COMPACTION TEST REPORTS FOR ALL FILL BY A QUALIFIED TESTING 3. ALL WORK THAT lS NEITHER SPECIFICALLY NOTED NOR SPECIFICALLY
1 o LAB TO ARCHITECT AND BUILDING DEPARTMENT PRIOR TO REQUESTING DETAILED, SHALL BE CONSTRUCTED IN ACCORDANCE WITH OTHER SIMILAR 5. ADMIXTURES MAY BE USED WITH THE PRIOR APPROVAL OF THE ENGINEER.
W a �� p FINISH GRADE 0 FOUNDATION INSPECTION. ALL LOOSE AND FILL SOILS SHALL BE COMPACTED WORK SHOWN ON THE DRAWINGS AND /OR WITH TYPICAL DETAILS, ADMIXTURES SHALL NOT REDUCE THE SPECIFIED MINIMUM COMPRESSIVE
Z ryxI o° o TO A MINIMUM OF 90% OF THE MAXIMUM SOIL DENSITY. STRENGTH OF THE CONCRETE. (CALCIUM CHLORIDE SHALL NOT BE USED).
66 x `l. r7 4. DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THE A. o� 6. CONCRETE MIXES SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY
17 A Q) �'y 4. CONTRACTOR SHALL PROVIDE FOR DE- WATERING OF EXCAVATIONS FROM CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY AND REVIEWED BY THE ENGINEER. MIX DESIGNS SHALL BE STAMPED AND
IFT TW 65:50 ^�x x"�k SURFACE OR SEEPAGE WATER. DEVICES, INCLUDING SHORING AND TEMPORARY BRACING. THE CONTRACTOR
+ fTw 64.83 y a SIGNED C A CIVIL ENGINEER CURRENTLY REGISTERED IN CALIFORNIA:
N TW 6¢•17. x SHALL TAKE ALL NECESSARY MEASURES AND BE RESPONSIBLE FOR THE
^� 7. MINIMUM CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE:
TW 63.50 5. THE MAXIMUM ALLOWABLE SOIL BEARING PRESSURE SHALL BE: SAFETY OF ALL PERSONS AND STRUCTURES AT THE VICINITY OF THE CONCRETE PANEL .......... ...........................3000 PSI
TW 62.83 ALLOWABLE BEARING SOIL = 2000 psf SOIL REPORT SITE. VISITS TO THE SITE BY THE ENGINEER SHALL NOT INCLUDE
INSPECTION OF SUCH MEASURES. CONTINUOUS FOOTINGS .. ...........................2500 PSI
6. FOOTING ELEVATIONS INDICATED ARE ASSUMED TO BE IN SUITABLE BEARING SPREAD F001INS ..... ............................... 2500 PSI
SOIL.THE ACTUAL ADEQUACY OF THE BEARING SOIL SHALL BE VERIFIED 5. ALL WORK SHALL CONFORM TO THE STANDARDS OF THE 2016 SLAB ON GRADE ...... ............................... 2500 PSI
TF 60.17 FINISH GRADE PRIOR TO PLACING ADEQUACY THE CALIFORNIA BUILDING CODE AS AMMENDED AND ADOPTED BY THE LATEST
O TF 59.50 ORDINANCE OF THE CITY OF SAN DIEGO, AND OTHER REGULATING AGENCIES 8. WHERE NO ADMIXTURES ARE USED, SLUMP SHALL NOT EXCEED 3" FOR SLABS
yx�p SOIL SLOPE EXERCISING AUTHORITY OVER ANY PORTION OF WORK. ON GRADE AND 4" FOR ALL OTHER CONCRETE WORK.
6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY SITE CONDITIONS 9. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS
PROFILE. RETAINING WALL 1 NOT REFLECTED ON THE DRAWINGS OR DIFFERENT FROM THE INDICATED FOR ALL SLEEVES, INSERTS, MOLDS, GROOVES, ORNAMENTAL CLIPS,...ETC, TO
MAXIMUM /MINIMUM DIMENSIONS, INCLUDING EARTH HEIGHT, CONFLICT IN BE CAST IN CONCRETE AND FOR EXTENT OF DEPRESSIONS, CURBS,.. ETC.
GRADES, ADVERSE SOIL CONDITIONS.... ETC.
SCALE: HORIZ. 1 " =6' 1336 SQ. FT. 10. NO CONDUITS OR PIPES PLACED IN THE SLAB SHALL HAVE AN OUTSIDE
VERT. 1 " =6' 7 THE AND SHALL CONTRACTOR ELY NOTIFY DIMENSIONS OF ANY STARTING DIAMETER GREATER THAN N A OF THE SLAB THICKNESS. 3. CONDUITS OR
10' -0" MIN. DAYUGH PIPES SHALL BE PLACED IN A SLAB THAT IS LESS THAN 3.5 THICK.
8. OPENINGS, POCKETS, ETC, SHALL NOT BE PLACED IN STRUCTURAL ELEMENTS EXCEPT FOR LOCAL OFFSETS, MINIMUM CLEAR DISTANCE BETWEEN CONDUITS
UNLESS SPECIFICALLY INDICATED OR APPROVED BY THE ENGINEER. AND PIPES, PLACED IN CONCRETE, SHALL BE 6 ".
9. TYPICAL BASIC DESIGN LOADS CRITEREA:
TYPICAL DETAIL SHOWING \-FOOTING VERTICAL LOADS: 11. PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC, SHALL BE
SDRSD C -03 THE MINIMUM HORIZONTAL ROOF & FLOOR DEAD LOAD: ....... .............................25 PSF FORMED WITH A 3/4" CHAMFER.
DISTANCE FROM THE ROOF LIVE LOAD: FLAT ROOF ....... .............................20 PSF
a a 0- FOOTING TO THE SLOPE 12. ALL FORMWORK MUST BE CLEANED, INSPECTED AND APPROVED PRIOR TO
M M M I SDRSD C -03 FACE. FLOOR LIVE LOAD =40 PSF , IF ANY PRIVATE DECKS LIVE LOAD ........... 60 PSF PLACING REINFORCEMENT. ALL REINFORCING BARS, ANCHOR BOLTS AND
0o m t. 0o n PUBLIC AREAS LIVE LOAD ............ 100 PSF INSERTS TO BE SECURED IN PLACE PRIOR TO POURING CONCRETE.
o LATERAL LOADS: LIGHT WEIGHT STORAGE 125 PSF
0o N Co M 1 q SEISMIC : ZONE FOUR , 13. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE A RESILIENT
± FINISH GRADE + + + + °o + WIND BASIC WIND SPEED = 110 MPH, WIND EXPOSURE: B TILE FINISH SHALL BE APPROVED BY THE ARCHITECT IN ADVANCE.
0
TW 61.50 + FINISH GRADE 10. ANY DISCRIPENCY IN THE DRAWNINGS DISCOVERED BY THE CONTRACTOR 14. CONTRACTOR SHALL SUBMIT JOINT LAYOUT FOR CONCRETE WORK TO BE APPROVED BY
AFTER THE CONSTRUCTION HAS STARED, IT IS THE CONTRACTOR'S RESPONSIBILTY THE ENGINEER PRIOR TO FABRICATION OF REINFORCING BARS. CONTROL JOINTS FOR
TW 61.50 TO DO FIX ON HIS OWN EXPENSES INTERIOR SLABS ON GRADES SHALL NOT BE SPACED MORE THAN 24' IN ANY DIRECTION.
gF 11. ALL DETAILS SHOWN ON STRUCTURAL DETAILS SHEETS ARE TO BE USED AS TYPICAL 15. REINFORCING STEEL SHALL HAVE A CONCRETE COVER AS FOLLOWS:
TF 57.50 1 N 1 1 t I 0°11p0111- DETAILS A) UNFORMED CONCRETE CAST AGAINST EARTH........... 3"
FINISH GRADE yd1�21k SIMPLIFY STATIC B) FORMED CONCRETE IN CONTACT WITH EARTH AND CONCRETE EXPOSED TO WEATHER
TF 57.50 FINISH GRADE BARS #6 AND LARGER .......................... 2"
PROFILE: RETAINING WALL 2 #508 "O.C. Site Class D BARS #5 AND SMALLER ....................... 1.5
EXIST GRADE Mapped Spectral Response C) CONCRETE NEITHER IN CONTACT WITH EARTH NOR EXPOSED TO WEATHER:
T=-T : Tip -ill -1!I F iT-
SCALE: HORIZ. 1 " =6' PROFILE: RETAINING WALL 2A III ,I'I I1 =III I! I- Acceleration Parameter, SS _1.178 SLABS, WALLS AND JOISTS:
" 174 SQ. FT. • 4 ®24 "O.C• I I1-1I I I = II 111 I I Mapped Spectral Response BARS #14 AND LARGER . ............................... 1.5
VERT. 1 =6 41402ONTAL I (i =1111 III Acceleration Parameter, S1 -0.454 BARS #11 AND SMALLER .............................. 3/4"
SCALE: HORIZ. 1 =6 REINFORCEMENT - (i Seismic Coefficient, Fa =1.029
- =i BEAMS AND COLUMNS (TO TIES) .................. 1.5"
144 SQ. FT. I Seismic Coefficient, Fv= 1.546
VERT. 1 -6 MICE Spectral Response UNPROTECTED COLUMNS (IN PARKING AREAS) ....... 2.5'
fm' 8" OUPSI I WATER PROOFING BY OTHERS Acceleration Parameter, SMS =1.212 THE ABOVE COVERAGE VALUES SHOULD NOT BE EXCEEDED BY MORE THAN
�^ �04?01;�' WITH SPECIAL I MICE Spectral Response 50% OF THE SPECIFIED VALUE.
tixp� 3�I�l� tti fc' INSPECTION
500 PSI 6>_g Acceleration 16. DOWELS E REINFORCEMENT NOF WALDLS SUPPORTS AND COLUMNS.
MATCH IN SIZE AND SPACING
2.75' Acceleration, Parameter SDS =0.808 17. CONCRETE WALLS SHALL BE REINFORCED WITH #4 0 12" O/C EACH WAY
WN 1 #5 08 "O.C• I #4 AND SMALLER fy= 40,000 PSI Design Spectral Response CENTERED IN WALL.
EXIST. GRADE Acceleration, Parameter SD7�.468
#5 AND GREATER fy= 60,000 PSI
TI; - =J1 L1 III -1I f -11� #5 ®8 "o.c. I PcAM=0.492 MASONRY:
#4 024 00.c. =1i _III __III '
r HORIZONTAL - =111 I F SEE NOTE B 1. CONCRETE BLOCK UNITS SHALL BE MEDIUM WEIGHT AND CONFORM TO
GNU + REINFORCEMENT I 111 =111 III ASTM C90,GRADE "N ".OPEN END UNITS SHALL BE GROUTED SOLID.
SHj 4 I_ (= (_) h #5 ®16 "O.C. T AND BOTTOM I r
� }OO�O ' +. 0 11_li FINISH GRADE m SEEINO NOTE Fill AUAoII 1�L�Z[s�U /1EJZEwED 2 PROVIDE DEEP CUT BOND BEAM UNITS WHERE HORIZONTAL REINFORCEMENT OCCURS.
12 5 I WATER PROOFING BY OTHERS = �Iri I�II 111 -I11 111- III - 111 - 111= 11�111�11 I A110 RM/i0�&D 6Y ESGit 3. BLOCKS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI.
1+ fm'$1500 PSI AS PL it P2 331. 4. MATERIALS SHALL CONFORM TO THE FOLLOWING U.B.0 STANDARDS:
r� WITH SPECIAL I • A) AGGREGATE: STANDARD 24- 21,AGGREGATE FOR MASONRY MORTAR
A. v INSPECTION
w STANDARD 24- 23,AGGREGATE FOR MASONRY GROUT
fc' =2500 PSI #4 AND SMALLER fy= 40,000 PSI 8 12"
#5 AND GREATER fy= 60,000 PSI 5-4" 1 NOTE A B) CEMENT: STANDARD #26- 1,PORTLAND CEMENT
2x� ?6� L C) LIME: STANDARD #24- 18,HYDRATED LIME FOR MASONRY PURPOSES
7x4333 2.75" (3) #4 T &B INSTALL PREFABRICATED VERTICAL SHEET 5. MORTAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AFTER
^ + 2
#5"?8 "O.C. I #4 012 "O.C. 4' -7.2" DRAINS USING SINGLE SIDED SITEDRAIN 28 DAYS. RECOMMENDED MIXING PROPORTIONS IN VOLUME:
0 MID SECTION
o PORTLAND CEMENT 1 PART
SEE NOTE B SHEET 180 SERIES (AMERICAN WICK DRAIN SAND (BASED ON DAMP LOOSE CONDITION) : 3 PARTS
1 #5 ®16 "O.C. T AND BOTTOM I : CORP.) OR APPROVED EQUAL. DRAIN IN A
P LIME : 3/8 PART
FINISH GRADE m 8"X8" KEY 6' -g" HEIGHT With 100 psf SURCHARGE STRIPPED DRAIN AT BASE PER SOILS REPORT. s' GROUT DYSHALL HAVE A
ENDEDIMXI1 G PROPORTIONS STRENGTH OF 2500 PSI AFTER
d I I I =1 I I -1 I I -1 11 =1 I I 1 11-1 I C I I� 11=1 I I-1 I ICI I I I '�
vwN` o S ECTI O N Z PORTLAND CEMENT : 1 PART
SNt 4 NOTE B SAND (BASED ON DAMP LOOSE CONDITION), : 3 PARTS
g 12" PEA GRAVEL (BASED ON DAMP LOOSE CONDITION) : 2 PARTS
7. PROVIDE PRISM TESTING AS PRESCRIBED BY SECS. 2105A & 2105A.3 OF THE CBC.
JV LANDMARK ENGINEERING CONTRACTOR TO LEAVE OUT THE MORTAR IN 8. MASONRY SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1500 PSI AFTER
QgOFESs 28 DAYS, (f'm = 1500 PSI).f'm SHALL BE DETERMINED IN ACCORDANCE
PLAN® RETAINING WALLS 1, 2 2A 3 AND 4 (3) #4 T & B ���E CEeclF2 CORPORATION IN THE VERTICAL SPACES BETWEEN ALL THE WITH SECTION 2105A OF THE C.B.C.
#4 012 o.C. i 3443 Camino Del Rio South BLOCKS IN THE FRONT COURSE ABOVE THE 9• RETAINING WALLS AND WALLS BELOW GRADE SHALL BE GROUTED SOLID.
`20' 0 MID SECTION 4'-6" Q 10. ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID.
SCALE: 1 =20 of No. 36292 Suite 204 SOIL OR PAVING (HEAD - JOINT) ON THE 11. LIFTS SHALL NOT EXCEED 6' IN HEIGHT.CLEANOUT HOLES SHALL BE
5'-4" HEIGHT with 100 sf SURCHARGE Exp. 06/30/18 San Diego, CA 92108 PROVIDED AT T14E BASE OF ALL GROUTED CELLS FOR POURS OVER 5' IN HEIGHT.
p * * g FRONT FACE OF WALL. 12. GROUT CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR
8 "XB" KEY SECTION 1 T C V1� ��� (619) 260 -0420 1.5" BELOW THE TOP OF THE UPPERMOST UNIT.
F OF CAUFO 13. IMMEDIATELY AFTER GROUTING, CONSOLIDATE GROUT USING MECHANICAL
VIBRATING EQUIPMENT.RODDING WILL NOT BE ACCEPTED.
SI DRA N CHECKED BY:
CHANGE NO. APPROVED DATE BENCHMARK SCALE AS -BUILT APPROVAL LEG EN INEERIN DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING O.
•�UI L.I �. DESCRIPTION: #1004 STATION NAME: ENC -04 PLANS PREPARED UNDER SUPERVISION REVS WALL PLANS FOR:
SET 2.5" CITY OF ENCINTAS BRASS DISC IN CASSOLATO RESIDENCES
IN DRAINAGE BOX INLET. HORIZONTAL: AS SHOWN /? DATE: G /® //rte
LOCATION: THE NORTHEAST CORNER OF THE evArRFNCE F. Cock 1375 NORTH VULCAN AVENUE 13531 -
ST OWAK CHRISTO ER L. M DOSKU
CITY OF ENCINITAS LEUCADIA OAKS PARK ON VERTICAL: AS SHOWN R.C.E. NO.: 36292 APN:254- 254 -12
THE WEST SIDE OF RAINTREE DRIVE. RIwIEwr�p( IMSFrcT® §tcµroR, ENbtNEE(t �-• L/ Q
LAWRENCE E. COLE �_ DATE �lC! l DATE / �rZ04S• PLANNING CASE NO: 16 -157 TPM /DR /CDP SHEET 5 OF
ELEV: 67.639 DATUM: NAVD 88 - �� ��2Dm ���'/•11,� EXP.: 6 30 18
iP2
Z
r
rri
d'
00
op
z 0
wW
z0
zp
wz
Q U
z
gM
T
L
COMPAC UNIT II
I
�� rJ
r C1l
O
18
CAP UNIT
SPECIAL INSPECTION REQUIREMENTS
1.) THE SITE SOILS ENGINEER SHALL VERIFY THAT THE SOILS CONDITIONS
ARE SUBSTANTIALLY IN CONFORMANCE WITH THE SOIL INVESTIGATION
REPORT AND MEET OR EXCEED THE VALUES FOR BACKFILL,
FOUNDATION AND RETAINED SOILS AS' SHOWN HEREON.
2.) THE SITE SOILS ENGINEER SHALL VERIFY THAT THE BASE,
AND KEYSTONE UNITS ARE ADEQUATELY INSTALLED AS SHOWN ON
THE WALL SECTION AT THE ELEVATIONS SHOWN ON THE PROFILE.
3.) THE SITE SOILS ENGINEER SHALL PROVIDE SOIL COMPACTION TEST
RESULTS, DEPTH OF FILL, RELATIVE DENSITY AND BEARING VALUES
AS REQUIRED.
FOOTNOTES:
A. THE CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE CALLED
INSPECTIONS REQUIRED BY SECTION 108 OF THE UNIFORM BUILDING CODE.
SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A CITY
INSPECTOR. ALL WORK REQUIRING SPECIAL INSPECTION WHICH IS INSTALLED
OR COVERED WITHOUT THE APPROVAL OF THE CITY INSPECTOR IS
SUBJECT TO REMOVAL.
B. CONTINUOUS INSPECTION IS REQUIRED DURING THE PERFORMANCE OF THE
WORK UNLESS OTHERWISE SPECIFIED ON THE APPROVED PLANS.
C. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL
INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY PRIOR TO
PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION.
KEMONE RETAINING WALL
1.) KEYSTONE RETAINING WALL WILL BE CONSTRUCTED WITH FULL
SPECIAL INSPECTION ACCORDING TO THE MANUFACTURE'S
SPECIFICATIONS.
2.) KEYSTONE RETAINING WALL WILL BE CERTIFIED BY THE ENGINEER OF
WORK AS BEING CONSTRUCTED ACCORDING TO THE MANUFACTURER'S
SPECIFICATIONS.
°o FINISH GRADE °o FINISH GRADE
O N 0 N
O
+ + + +
TW
fTw 91 rn 62.50 TW
FINISH GRADE
PROFILE: KEYSTONE RETAINING WALL 3
SCALE: HORIZ. 1 " =6'
VERT. 1 " =6' 43 SQ. FT.
I�UL I KUJIUIN 1' 11:JLN iLHJJ
7
FINISH GRADE
SEE SPECIAL INSPECTION
PREPARED BY: SES cEN'EA
DATED: 121W/9
ON FILE WITH THE ENGINEERING
DIVISION
PROFILE: KEYSTONE RETAINING WALL 4
OR 8"
a
UNIT II
N GTH
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO
SCALE: HORIZ. 1 " =6'
VERT. 1 " =6' 38 SQ. FT.
Ado rE
TF✓E iGES���A/� B�o6![ tag y
EquAL . Act- 5,EGA4EAwr0vL°
w.®t..5 486' GEESar,A 3 FEAT
NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD
UNAUTHORIZED CHANGES &
USES: THE ENGINEER PREPARING
DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
THESE PLANS WILL NOT
BE
RESPONSIBILE
FOR,
OR LIABLE FOR, UNAUTHORIZED
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN
CHANGES TO OR USES
OF
THESE PLANS.
ALL
CHANGES TO THE PLANS MUST BE
PROFESSIONAL.
IN WRITTING AND MUST
BE
APPROVED BY
THE
PREPARER OF THESE PLANS.
CHANGE N0. APPROVED DATE
BENCHMARK
1/2 OR 1 SQUARE FOOT
SCALE
AS -BUILT APPROVAL
NOTE: CONTRACTOR TO LOCATE AND PROTECT ALL EXISTING UNDERGROUND
UTILITIES PRIOR TO COMMENCING CONSTRUCTION OF THE WALL. IT WILL
BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT THE UTILITIES
DURING THE CONSTRUCTION OF THE WALL.
4" OR 8" CAP UNITT--,,\
COMPAC UNIT II (TYP.) --,
FINISH GRADE —\
GENERAL INFORMATION ESR -2113
ABSORPTION RATE
8% (MAXIMUM)
COMPRESSION STRENGTH
3000 PSI (APPROXIMATELY)
COMPOSITION
"0" SLUMP CONCRETE
COMPAC II UNIT
WEIGHT
82 LBS. (APPROXIMATELY)
SIZE
8 "H X 18 "W X 12 "D
EXPOSED FACE
1 SQUARE FOOT (8" X 18 ")
CAP'; UNIT ( 4" OR 8"
)
WEIGHT
45 OR 88 LBS. (APPROXIMATELY)
SIZE
4" OR 8 "H X 18 "W X 10.5 "D
EXPOSED FACE
1/2 OR 1 SQUARE FOOT
PINS
ALL UNIT TYPES
1/2" X 5 1/4" HIGH STRENGTH
DESIGNED
PULTRUSION FIBERGLASS
TENSILE STRENGTH
110,000 PSI
TENSILE MODULUS
4 X 10 PSI 6
FLEXURAL STRENGTH
128,000 PSI
FLEXURAL MODULUS
4 X10 PSI 6
SHORT BEAM SHEAR STRENGTH
6,400 PSI
SPECIFIC GRAVITY
1.83 PSI
ALL KEYSTONE UNITS COMPLY AS
GRADE "N ", TYPE 1,
IN ACCORDANCE WITH UBC STANDARD
21 -4.
SEE ICC -ES EVALUATION REPORT
ESR -2113 DATED 8/1/2013
NOTE: CONTRACTOR TO LOCATE AND PROTECT ALL EXISTING UNDERGROUND
UTILITIES PRIOR TO COMMENCING CONSTRUCTION OF THE WALL. IT WILL
BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT THE UTILITIES
DURING THE CONSTRUCTION OF THE WALL.
4" OR 8" CAP UNITT--,,\
COMPAC UNIT II (TYP.) --,
FINISH GRADE —\
BW
11 =1111
BACKFILL SHALL MEET
OR EXCEED 135 lbs.
UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
W =30
COMPACT TO 90 PERCENT
PER ASTM D -1557
3/4" CRUSHED. AGGREGATE
FOUNDATION SOIL SHALL MEET
BASE (6' MIN.) OR EXCEED 135 lbs.
GRAVITY Y Y ALL UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
1Q° =30
TYPICAL SECTION RETAINED SOIL SHALL MEET
NO SCALE OR EXCEED 135 lbs.
UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
N* =30
CONTRACTOR TO USE REAR PINS
KEYSTONE WALL INSTALLATION NOTES
BACKFILL MATERIAL MUST HAVE THE PROPER MOISTURE LEVEL FOR OPTIMUM PERFORMANCE
WHEN COMPACTING.
ORGANIC OR HEAVY CLAY MATERIAL SHOULD NOT BE USED. THESE MATERIALS HOLD
MOISTURE AND DO NOT COMPACT PROPERLY.
WALK BEHIND MECHANICAL COMPACTION EQUIPMENT MAY BE USED TO COMPACT ANY SOILS
PLACED BEYOND THE UNIT /DRAINAGE ZONE.
RIDE —ON MECHANICAL COMPACTION EQUIPMENT SHOULD BE OPERATED NO CLOSER THAN
WITHIN 3 FEET OF THE KEYSTONE UNIT BACK SURFACE.
DO NOT OVER COMPACT OR COMPACT SOILS NEXT TO THE BACK OF THE UNIT IN AN
UNCONTROLLED MANNER. THIS MAY DRIVE DRAINAGE MATERIAL UNDER THE UNIT,
RAISING THE REAR ELEVATION AND FORCING THE UNITS OUT OF LEVEL. IF THIS
CONTINUES, THE WALL WILL BEGIN TO LEAN FORWARD.
ALL SOILS TESTING SHOULD BE PERFORMED BY A QUALIFIED ENGINEER. SOIL TESTS
SHOULD BE TAKEN NO CLOSER THAN WITHIN THREE FEET OF THE BACK SURFACE OF
THE KEYSTONE UNIT.
FILL FOR UNITS SHALL BE FREE DRAINING GRAVEL. NO MORE THAN 10 PERCENT SHALL.
PASS THE NO. 200 SIEVE WITH A MAXIMUM SIZE OF 3/4 ". GRADATION APPROVED BY
THE ENGINEER.
QFtOFESS/0
�.
LANDMARK ENGINEERING
�•
DESCRIPTION: #1004 STATION NAME: ENC -04
SET 2.5" CITY OF ENCINITAS BRASS DISC IN
IN DRAINAGE BOX INLET.
LOCATION: THE NORTHEAST CORNER OF THE
CITY OF ENCINITAS LEUCADIA OAKS PARK ON
THE WEST SIDE OF RAINTREE DRIVE.
ELEV: 67.639 DATUM: NAVD 88
HORIZONTAL: AS SHOWN
VERTICAL: AS SHOWN
i
Ae^vA6AtCE • CoG
EVIEW�Q ��liPEcfo0. SEMI 0.EalGN!
ry� nn
��•� r�a' �Y� �. ��'
BW
11 =1111
BACKFILL SHALL MEET
OR EXCEED 135 lbs.
UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
W =30
COMPACT TO 90 PERCENT
PER ASTM D -1557
3/4" CRUSHED. AGGREGATE
FOUNDATION SOIL SHALL MEET
BASE (6' MIN.) OR EXCEED 135 lbs.
GRAVITY Y Y ALL UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
1Q° =30
TYPICAL SECTION RETAINED SOIL SHALL MEET
NO SCALE OR EXCEED 135 lbs.
UNIT WEIGHT WITH A
SOIL FRICTION ANGLE
N* =30
CONTRACTOR TO USE REAR PINS
KEYSTONE WALL INSTALLATION NOTES
BACKFILL MATERIAL MUST HAVE THE PROPER MOISTURE LEVEL FOR OPTIMUM PERFORMANCE
WHEN COMPACTING.
ORGANIC OR HEAVY CLAY MATERIAL SHOULD NOT BE USED. THESE MATERIALS HOLD
MOISTURE AND DO NOT COMPACT PROPERLY.
WALK BEHIND MECHANICAL COMPACTION EQUIPMENT MAY BE USED TO COMPACT ANY SOILS
PLACED BEYOND THE UNIT /DRAINAGE ZONE.
RIDE —ON MECHANICAL COMPACTION EQUIPMENT SHOULD BE OPERATED NO CLOSER THAN
WITHIN 3 FEET OF THE KEYSTONE UNIT BACK SURFACE.
DO NOT OVER COMPACT OR COMPACT SOILS NEXT TO THE BACK OF THE UNIT IN AN
UNCONTROLLED MANNER. THIS MAY DRIVE DRAINAGE MATERIAL UNDER THE UNIT,
RAISING THE REAR ELEVATION AND FORCING THE UNITS OUT OF LEVEL. IF THIS
CONTINUES, THE WALL WILL BEGIN TO LEAN FORWARD.
ALL SOILS TESTING SHOULD BE PERFORMED BY A QUALIFIED ENGINEER. SOIL TESTS
SHOULD BE TAKEN NO CLOSER THAN WITHIN THREE FEET OF THE BACK SURFACE OF
THE KEYSTONE UNIT.
FILL FOR UNITS SHALL BE FREE DRAINING GRAVEL. NO MORE THAN 10 PERCENT SHALL.
PASS THE NO. 200 SIEVE WITH A MAXIMUM SIZE OF 3/4 ". GRADATION APPROVED BY
THE ENGINEER.
QFtOFESS/0
�.
LANDMARK ENGINEERING
ENCE o�Fyc
CORPORATION
3443 Camino Del Rio South
No. 36292
Suite 204
Exp. 06 /30/18.
* *
San Diego, CA 92108
r Civ\\, R
F OF CAUFO
619 260 -0420
( )
DESIGNED
DRAWN
BY: C CKED BY: LEC EN INE ING DIVISION APPROVALS
CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT
PLANS PREPARED
UNDER
SUPERVISION_ 9F,
REVIE
WALL PLANS FOR: CASS()LAT® RESIDENCES
DATE: G�l�
1315 ORTFI VULCAN A�/ENLJE
R.C.E. NO.: 36292
STE NOWAK CHRIST HER L. MA 0SKU
4 -254-
AP[V:254- 25412
LAWRENCE E. COLE
EXP.: 6/30/18
DATE "��� DATE Y-1 9-2019-
PLANNING CASE NO: 16 -157 TPM /DR /CDP
13531 -