2019-14167-G (Plans)RIGHT-OF-WAY N 0 TE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS /HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORTS TITLED "PRELIMINARY GEOTECHNICAL INVESTIGATION AND FOUNDATION RECOMMENDATIONS PROPOSED NEW TWIN HOMES TO BE LOCATED AT 2139 -2414 MONTGOMERY AVENUE, CARDIFF -BY- THE -SEA, CALIFORNIA" PREPARED BY ENGINEERING DESIGN GROUP DATED DECEMBER 4, 2018 AND SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORTS. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE - CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE - CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633 -2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK OF CER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND /OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL { BE PROVIDED STATING: "THE GRADING UNDER PERMIT NO. ( 6]l G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12, ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT THOMAS SCHROEDER AT (619) 884 -3660, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP /IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP /IMP FACILITIES AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITY AND /OR THE TURF /LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP /BMP. 6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON- COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY - APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. SAN DIEGUITO WATER DISTRICT NOTES 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). 2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON- EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND /OR ADJUST TO GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE. 5. UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 6. MINIMUM HORIZONTAL SEPARATION OF 10 -FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING. 8. CALIFORNIA STATE LAW ASSEMBLY BILL AB -1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC -17 OR WC -18. N 0 TI FI CA TIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWER - CARDIFF SANITARY DIVISION - 760 -633 -2840 B. GAS & ELECTRIC - SDGE - (760)- 438 -6200 C. WATER - SAN DIEGUITO WATER DISTRICT -1- 800 -227 -2600 D. TELEPHONE - SBC BELL - (760)- 489 -3411 E. CABLE TV - COX COMMUNICATIONS- (760)- 806 -9809 X -2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)- 633 -2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL PANELS /PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST- GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER (S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS /DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON- RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436 -4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633 -2770. EARTHWORK DATA STEEPEST EXISTING NATURAL SLOPE ON -SITE = 4 H 1 V MAXIMUM VERTICAL DEPTH OF CUT = 9 FT MAXIMUM VERTICAL DEPTH OF FILL = 13 FT CUT = ±225 C.Y. FILL = ±150 C.Y. EXPORT = ±70 C.Y. REMEDIAL = ±210 C.Y. * ESTIMATE DOES NOT INCLUDE STRIPPINGS, UTILITY TRENCH VOLUMES OR ANY OVEREXCAVATION, IF REQUIRED BY SITE CONDITIONS. CONTRACTOR SHALL CONFIRM THAT ESTIMATES ARE CORRECT PRIOR TO COMMENCEMENT OF WORK. EARTHWORK QUANTITIES ARE ESTIMATED FOR PERMIT PURPOSES ONLY. (CALCULATED ON A THEORETICAL BASIS. ACTUAL QUANTITIES MAY VARY DUE TO SHRINKAGE OR SWELL FACTORS). REMEDIAL GRADING QUANTITIES ARE NOT ABLE TO BE DETERMINED. REFER TO SOILS REPORT FOR REMOVAL AND RECOMPACTION DEPTHS. IMPERVIOUS AREAS IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 3715 SQFT IMPERVIOUS AREA AFTER CONSTRUCTION: 4104 SQFT INCREASE IN IMPERVIOUS AREA: 389 SQFT IMPERVIOUS AREA REPLACED: 3715 SQFT DRIVEWAY (IMPERVIOUS): 1083 SQFT TOTAL AREA OF LAND DISTURBANCE= 5008 SQFT • OWNER /PERMI TTEE THOMAS SCHROEDER 3518 CALLE GAVANZO CARLSBAD, CA, 92009 619 - 884 - 3660 SITE ADDRESS 2139 MONTGOMERY AVENEU ENCINITAS, CA 92007 APN: 260 - 403 -08 LEGAL DESCRIPTION LOT 37 AND 38 IN BLOCK 58 OF CARDIFF "A" IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO PARCEL MAP THEREOF NO. 1334, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, MAY 12, 1911. TOPOGRAPHY PASCO LARET SUITER & ASSOCIATES PH 858- 259 -8212 DATE OF SURVEY: APRIL 24, 2018 OWNER'S CERTIFICATE VICINITY MAP I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITH THE PRIVATE PROPE OR PUBLIC EASEMENTS. 2 -II SIGNATU E�� DATE: �D 4' Y Hof OMAS S ROEDER TRUSTEE THOMAS S. SCHROEDER LIVING TRUST SOILS ENGINEER'S CERTIFICATE I, ERIN RIST A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 1 -18 -2016 AND FOR AN UPDATE ON 10 -6 -2016. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADIN�lG S AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJKT HAVE EN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. 13 z m N_ plapopm-i� RCE NO.: 65122 EXP. DATE: 09/301;32.1' JOB #. 186063 -1 ENGINEERING DESIGN GROUO�f 2121 MONTIEL ROAD SAN MARCOS, CA 92069' PHONE: (760)- 839 -7302' , SHEETINDEx SHEET DESCRIPTION 1 TITLE SHEET 2 GRADING PLAN 3 EROSION CONTROL PLAN 4 -8 SHORING PLANS STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PU3LIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. QROf ESS /Oy O �GHAEC SIGNATURE: DATE: JO-2"l-It 9P� F BRIAN OUNO RCE No. 71651 h Q� 0_-0- (p PASCO LARET SUITER & ASSOCIATES w m No. 71651 'D m 535 N. COAST HIGHWAY 101 s Exp. 12/31/19 - SOLANA BEACH CA, 92074 RCE EXPIRES 12 -31 -19 ITA CIVIV BMP - • STANDARD I c, It fe /I el aMA6"40 9-E-19 DATE SI 'DATE SIGN DATE 'SIGN DATE SIGN DATE CHANG= NO DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS utawivtu n : unH ter: UntWncu rsr. ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING N®. A DESCRIPTION: 2.5" BRASS DISC THE SOUTHEAST QUANDRANT OF LEUC ADIA BLVD. AND ORPHEUS AVE. PER ROS 18416, AS PT N0. 1024 RECORD FROM: ELEVATION: IE 178.543 DATUM: NAVD88 INT, DATE PLANS PREPARED UNDER SUPERVISION OF DATE: `1� R.C.E. NO.: 71651 B N AR INO EXP.: 12- 31- 19°� RECOMMENDED: C ? s VED: JE E OWENS EDWARD J. WI R ���Y NGI E Al- "1 DATE DAT GRADING PLAN FOR: 2139 MONTGOMERY AVENUE APN: 260 - 403 -08 18 -114 DR 11 CDP 14167-G PUBLIC WORKS BRIAN ARDOLINO DATE PLANNING REVIEWER SENIOR ENGINEER DATE INSPECTOR SHEET 1 OF 8 PLSA 2832 �L J 'U4 o (� �O � J QQ �m �Q WW Q J N OCN LO N m Z amp �O Wz ZW 3 W� wx -201- to EXISTING EDGE OF -NI I PAVEMENT (E) MONUMENT TO BE I PROTECTE -IN -PLACE 103 87 E 18 11S CUT 1404 PROPOSED . LINE 4" SEVER LATERAL :::...........:... TRENCH RESURFACE . PER CITY OF t ENCINITAS PROPOSED t0l�r ;STANDARDS BIORETENTION EXISTING BASIN 84 SF 10" SEWER FG 103.49 w MAIN SUMP & PUMP TTOMLESS BOX 1 WEEP HOLES PROPOSED 36" )LOW WALL ATOP RETAINING WALL 104 SDRSD TYPE C -1 O•7 SUMP &PUMP 1 357 !�, TO BOTTOMLESS ;� � Box 0" FLUSH 6'X16" PCC � ?, x CURB E WEEP HOLES co (2%) A ~- 103.271E 1" SEWER PROPOSED CtS MAIN BIORETENTION ,. BASIN 84 SF PROPOSED FG 103.27 4 "SEWER . #': ............... LATERAL TRENCFI%RESURFACE PROPOSED I PER CITY OF ENCINITAS 42 "WIDE SY {STANDARDS 36 "HIGH WOOD I j GATE (TYP.) 4( 103.79 EX t in PROPOSED i PERVIOUS PAVERS � 1 X 4� i f , t?a V` it NOTES: _. 104.6411. .19 FS 105.70 tW 104.03 AW (E) MONUMENT TO BE x 1 ;PROP �FENglr I PROTECTED -IN -PLACE PROPOSED 0 `"'1 18'X42" F{1LASTER (TYP.) E4 C PROPOSED SDRSD C -3 PROPOSED RETAINING WALL SDRSD TYPE C -1 f l RETAINING WAL 11 .4 TG 110.63 - 1 .' 0 1,07.77 TS 1 9.46 IE 108.70 108.00\TW 104.77$W x ; - - 107.80T1� 106.871E 107.453 BW 197.96 BS 110 5T G 109.57 f <. 113.28 TG fix" 11Z28 IE 100 _. 104.6411. .19 FS 105.70 tW 104.03 AW (E) MONUMENT TO BE x 1 ;PROP �FENglr I PROTECTED -IN -PLACE W RETAII)IING iii j 3i t1 ✓ PROPOSED TYR J 110.73 FS VE ` SECOND FF= 120.83 EGRESS EXISTING ' FIRST FF = 110.83 LIGHT BUILDING TO BE BASEMENT FF = 101.25 WELL REMOVED 3AS ESMENT PAD = 100.58 FS 103.58 UNIT 1 s.001G «102.65 TG: )RN: 260- 403 -08 101.65 IE V) 9HT WELL iL OF BLDG. 102.75 1 1R1 : WALL Ll TWELL G) UNIT2 ° ARN: 260 - 403 -08 E SECOND FF= 123.08 n 103.48 T( FIRST FF = 114.75 102.48 /E BASEMENT FF = 104.25 BASEMENT PAD = 103.58 S � ¢" PVC TY EL FS 103. „ ENCROACHMENT MAINTENANCE AND REMOVAL AGREEMENT RECORDED AL03/ 12, 2019 AS DOCUMENT NO, 2019 -StI SOJ OF O.R. 1. ALL SERVICE LINES TO THE SUBJECT BUILDING SHALL BE CONSTRUCTED UNDERGROUND. 2. ALL STREET SIGNS, LIGHTS, LAMPS, UTILITIES, ETC. LOCATED WITHIN THE PUBLIC RIGHT -OF -WAY SHALL BE PROTECTED IN -PLACE DURING CONSTRUCTION OR REPLACED TO THE SATISFACTION OF THE CITY ENGINEER.` 3. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SEWER LATERAL. MONUMENT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FORANY MONUMENTATION AND /OR BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BYA LICENSED LAND SURVEYOR OR REGISTERED CIVIL ENGINEER AUTHORIZED TO PRACTICE LAND SURVEYING. A CORNER RECORD OR RECORD OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE LICENSED LAND SURVEYOR OR THE REGISTERED CIVIL ENGINEERAS REQUIRED BYTHE LAND SURVEYOR'SACT. GE N0] DESCRIPTION I APPROVED I DATE 1 12' TO 4 112.30 EXCEED 6' WITH RET. IE BOTTOMLESS BOX FOR PUMP OUTLET 61X16" PCC PERMEABLE PAVERS FLUSH CURB ORCOAQUA -BRIG OR APPROVED EQUAL GRIND & OVERLAY EXISTINGAC zo/o - Os (E) TO (W 119.0 BW TgW.& to 12 OEX - STRICT TO INSTALL 1" WATER LATERAL,; I D DUAL METER PEk EX' 8" ISWS =09, C -VRte.. -_- 14EWER OWNER'S EXPENSE \�, MAIN ze 3: w I M1} i SDRSD C -1 RET. WALL I I BIORETENTIONAREA PER DETAIL THIS SHT. PVC 4" THICK OF G It2",-11 .. , .. , .0 -a� 1; tai \� (NO. 57) CRUSHED ROCK FLUSH CUR 6" LAYER OF 314" CRUSHED ROCK SECTIONA A: MONTGOMERYAVE. FRONTAGE IMPROVEMENTS NOT TO SCALE >- TRANSITION /FEATHER ALLEY IMPROVEMENTS TO MEET EXISTING OFFSITE TO BE °- (E) WATER METER TO REMAIN, ADJUST WATER METER BOX TO GRADE 118.89 EX DISTRICT TO UPGRADE TO 1 " WATER LATERAL & DUAL METER PER WAS WS -09, WC -17AT 8 OWNER'S EXPENSE; ADJUST METER BOX TO GRADE 119.66 EX 119.40 FL - PROPOSED PCC RIBBON GUTTER PROPOSED 4" ASPHALT PAVING OVER 6" CLASS It BASE - (E) SEWER MANHOLE TO REMAIN; ADJUST RIM TO GRADE 120.56 EX 1, TRANSITION /FEATHER ALLEY IMPROVEMENTS TO MEET EXISTING APPROXIMATE X LOCATION OF 6 "ACP WATER Q �� 4"X24" 2 BROOKS BOX j\�tll,/ /LID) PROPOSE DRIVEWi PER PD P/L SDRSD C -1 RET. WALL WEEPHOLES I FOR OVERFLOW 4" MIN. WO LOCATIONS PER PLAN N 24" b ENGINEERED *SEE NOTE BE DROUGHT TOLERANT PLANTS (TYP.) DEEPENED SD DRAIN PIPE lI I CURB WALL I' PER PLAN YER OF HARDWOOD :H /GRASS COVER OF APPROVED EQUIVALENT A" V��2" LAYER OF � 318" GRAVEL 12" LAYER OF 314" GRAVEL SEE NOTE BELOW 4" PVC I TO SUMP & PUMP (SEESECTIONA -A) * BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 24" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 50 -60% SAND, 20 -30% COMPOST OR HARDWOORD MULCH, AND 20 -30% TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. ** 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON CALCULATION. TYPICALLY, THE SURFACE AREA OF THE BIORETENTION BASIN IS 4% OF THE IMPERVIOUS AREA DRAINING TO IT ALL BIORETENTION PLANTERS TO BE DEPRESSED AT LEAST 6" BELOW ADJACENT FINISHED SURFACE BIORETENTION AREA DETAIL NOT TO SCALE PI/L PI/L I I I SECTION B -B: ALLEY IMPROVEMENTS NOT TO SCALE UtJIIaIVtU CST: UK8 UT: UHLUKLU CT: BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS DESCRIPTION: 2.5" BRASS DISC IN THE INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECD MENDE AP OVED: SOUTHEAST QUANDRANT OF LEUCADIA BLVD. AND ORPHEUS AVE. PER ROS 18416, AS PT PUBLIC WORKS DATE: Io 2N•1i NO. 1024 BRIAN ARDOLINO DATE RECORD FROM: PLANNING R.C.E. NO.: 71651 JESA OWENS EDWARD J. MER ELEVATION: IE 178.543 CITY ENG N R DATUM: NAVD88 SENIOR ENGINEER DATE REVIEWER BRIAN M. RD LINO �� y�� INSPECTOR EXP.: 12 -31 -19 DATE DAT PROPERTY LINE CENTER LINE EXISTING WATER LINE EXISTING SEWER LINE 398 - - - -- EXISTING CONTOUR LINE WANMOMINNEWAMM EXISTING STRUCTURE PROPOSED SETBACKS PROPOSED BUILDING FOOTPRINT PROPOSED DECKABOVE PROPOSED ROOF ABOVE + + + + + + PROPOSED PERMANENT BMPAREA ° PROPOSED CONCRETE PROPOSED AC PAVEMENT PROPOSED BASEMENT WALL 38 PROPOSED CONTOUR LINE PROPOSED RETAINING WALL PROPOSED STORM DRAIN INLET PROPOSED STORM DRAIN PROPOSED SO PUMP FS FINISHED SURFACE FG FINISHED GRADE FL FLOW LINE FF FINSHED FLOOR FYSB FRONT YARD SETBACK SYSB SIDE YARD SETBACK RYSB REAR YARD SETBACK TOP OF WALL (TW) BOTTOM OF WALL (BM TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOT TO SCALE IZQ I %C QRpf ESSlOy /V c0 CNAE( '< O o 0 z� rm No. 71651 om ¢Q Exp. 12/31/19 `0 ce m J J> CIV11 F OF CAS \F� Lu w S 10 5 0 10 20 30 p 1 hHod U N (n ¢I GRAPHIC SCALE IN FEET (L 0) iii N CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. z Lo GRADING PLAN FOR: 2139 MONTGOMERY AVENUE °z 14167 -G Z Z APN: 260 - 403 -06 w a 8 -114 DR p CDP SHEET 2 OF 8 PLSA 2832 E SECOND FF= 123.08 n 103.48 T( FIRST FF = 114.75 102.48 /E BASEMENT FF = 104.25 BASEMENT PAD = 103.58 S � ¢" PVC TY EL FS 103. „ ENCROACHMENT MAINTENANCE AND REMOVAL AGREEMENT RECORDED AL03/ 12, 2019 AS DOCUMENT NO, 2019 -StI SOJ OF O.R. 1. ALL SERVICE LINES TO THE SUBJECT BUILDING SHALL BE CONSTRUCTED UNDERGROUND. 2. ALL STREET SIGNS, LIGHTS, LAMPS, UTILITIES, ETC. LOCATED WITHIN THE PUBLIC RIGHT -OF -WAY SHALL BE PROTECTED IN -PLACE DURING CONSTRUCTION OR REPLACED TO THE SATISFACTION OF THE CITY ENGINEER.` 3. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SEWER LATERAL. MONUMENT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FORANY MONUMENTATION AND /OR BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BYA LICENSED LAND SURVEYOR OR REGISTERED CIVIL ENGINEER AUTHORIZED TO PRACTICE LAND SURVEYING. A CORNER RECORD OR RECORD OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE LICENSED LAND SURVEYOR OR THE REGISTERED CIVIL ENGINEERAS REQUIRED BYTHE LAND SURVEYOR'SACT. GE N0] DESCRIPTION I APPROVED I DATE 1 12' TO 4 112.30 EXCEED 6' WITH RET. IE BOTTOMLESS BOX FOR PUMP OUTLET 61X16" PCC PERMEABLE PAVERS FLUSH CURB ORCOAQUA -BRIG OR APPROVED EQUAL GRIND & OVERLAY EXISTINGAC zo/o - Os (E) TO (W 119.0 BW TgW.& to 12 OEX - STRICT TO INSTALL 1" WATER LATERAL,; I D DUAL METER PEk EX' 8" ISWS =09, C -VRte.. -_- 14EWER OWNER'S EXPENSE \�, MAIN ze 3: w I M1} i SDRSD C -1 RET. WALL I I BIORETENTIONAREA PER DETAIL THIS SHT. PVC 4" THICK OF G It2",-11 .. , .. , .0 -a� 1; tai \� (NO. 57) CRUSHED ROCK FLUSH CUR 6" LAYER OF 314" CRUSHED ROCK SECTIONA A: MONTGOMERYAVE. FRONTAGE IMPROVEMENTS NOT TO SCALE >- TRANSITION /FEATHER ALLEY IMPROVEMENTS TO MEET EXISTING OFFSITE TO BE °- (E) WATER METER TO REMAIN, ADJUST WATER METER BOX TO GRADE 118.89 EX DISTRICT TO UPGRADE TO 1 " WATER LATERAL & DUAL METER PER WAS WS -09, WC -17AT 8 OWNER'S EXPENSE; ADJUST METER BOX TO GRADE 119.66 EX 119.40 FL - PROPOSED PCC RIBBON GUTTER PROPOSED 4" ASPHALT PAVING OVER 6" CLASS It BASE - (E) SEWER MANHOLE TO REMAIN; ADJUST RIM TO GRADE 120.56 EX 1, TRANSITION /FEATHER ALLEY IMPROVEMENTS TO MEET EXISTING APPROXIMATE X LOCATION OF 6 "ACP WATER Q �� 4"X24" 2 BROOKS BOX j\�tll,/ /LID) PROPOSE DRIVEWi PER PD P/L SDRSD C -1 RET. WALL WEEPHOLES I FOR OVERFLOW 4" MIN. WO LOCATIONS PER PLAN N 24" b ENGINEERED *SEE NOTE BE DROUGHT TOLERANT PLANTS (TYP.) DEEPENED SD DRAIN PIPE lI I CURB WALL I' PER PLAN YER OF HARDWOOD :H /GRASS COVER OF APPROVED EQUIVALENT A" V��2" LAYER OF � 318" GRAVEL 12" LAYER OF 314" GRAVEL SEE NOTE BELOW 4" PVC I TO SUMP & PUMP (SEESECTIONA -A) * BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 24" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 50 -60% SAND, 20 -30% COMPOST OR HARDWOORD MULCH, AND 20 -30% TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. ** 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON CALCULATION. TYPICALLY, THE SURFACE AREA OF THE BIORETENTION BASIN IS 4% OF THE IMPERVIOUS AREA DRAINING TO IT ALL BIORETENTION PLANTERS TO BE DEPRESSED AT LEAST 6" BELOW ADJACENT FINISHED SURFACE BIORETENTION AREA DETAIL NOT TO SCALE PI/L PI/L I I I SECTION B -B: ALLEY IMPROVEMENTS NOT TO SCALE UtJIIaIVtU CST: UK8 UT: UHLUKLU CT: BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS DESCRIPTION: 2.5" BRASS DISC IN THE INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECD MENDE AP OVED: SOUTHEAST QUANDRANT OF LEUCADIA BLVD. AND ORPHEUS AVE. PER ROS 18416, AS PT PUBLIC WORKS DATE: Io 2N•1i NO. 1024 BRIAN ARDOLINO DATE RECORD FROM: PLANNING R.C.E. NO.: 71651 JESA OWENS EDWARD J. MER ELEVATION: IE 178.543 CITY ENG N R DATUM: NAVD88 SENIOR ENGINEER DATE REVIEWER BRIAN M. RD LINO �� y�� INSPECTOR EXP.: 12 -31 -19 DATE DAT PROPERTY LINE CENTER LINE EXISTING WATER LINE EXISTING SEWER LINE 398 - - - -- EXISTING CONTOUR LINE WANMOMINNEWAMM EXISTING STRUCTURE PROPOSED SETBACKS PROPOSED BUILDING FOOTPRINT PROPOSED DECKABOVE PROPOSED ROOF ABOVE + + + + + + PROPOSED PERMANENT BMPAREA ° PROPOSED CONCRETE PROPOSED AC PAVEMENT PROPOSED BASEMENT WALL 38 PROPOSED CONTOUR LINE PROPOSED RETAINING WALL PROPOSED STORM DRAIN INLET PROPOSED STORM DRAIN PROPOSED SO PUMP FS FINISHED SURFACE FG FINISHED GRADE FL FLOW LINE FF FINSHED FLOOR FYSB FRONT YARD SETBACK SYSB SIDE YARD SETBACK RYSB REAR YARD SETBACK TOP OF WALL (TW) BOTTOM OF WALL (BM TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOT TO SCALE IZQ I %C QRpf ESSlOy /V c0 CNAE( '< O o 0 z� rm No. 71651 om ¢Q Exp. 12/31/19 `0 ce m J J> CIV11 F OF CAS \F� Lu w S 10 5 0 10 20 30 p 1 hHod U N (n ¢I GRAPHIC SCALE IN FEET (L 0) iii N CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. z Lo GRADING PLAN FOR: 2139 MONTGOMERY AVENUE °z 14167 -G Z Z APN: 260 - 403 -06 w a 8 -114 DR p CDP SHEET 2 OF 8 PLSA 2832 Q �� 4"X24" 2 BROOKS BOX j\�tll,/ /LID) PROPOSE DRIVEWi PER PD P/L SDRSD C -1 RET. WALL WEEPHOLES I FOR OVERFLOW 4" MIN. WO LOCATIONS PER PLAN N 24" b ENGINEERED *SEE NOTE BE DROUGHT TOLERANT PLANTS (TYP.) DEEPENED SD DRAIN PIPE lI I CURB WALL I' PER PLAN YER OF HARDWOOD :H /GRASS COVER OF APPROVED EQUIVALENT A" V��2" LAYER OF � 318" GRAVEL 12" LAYER OF 314" GRAVEL SEE NOTE BELOW 4" PVC I TO SUMP & PUMP (SEESECTIONA -A) * BIORETENTION "ENGINEERED SOIL" LAYER SHALL BE MINIMUM 24" DEEP "SANDY LOAM" SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 50 -60% SAND, 20 -30% COMPOST OR HARDWOORD MULCH, AND 20 -30% TOPSOIL, FREE OF STONES, STUMPS, ROOTS, OR SIMILAR OBJECTS, AND ALSO FREE OF NOXIOUS WEEDS. ** 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM OF 12" BUT MAY BE DEEPENED TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE DETAIL THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED ON CALCULATION. TYPICALLY, THE SURFACE AREA OF THE BIORETENTION BASIN IS 4% OF THE IMPERVIOUS AREA DRAINING TO IT ALL BIORETENTION PLANTERS TO BE DEPRESSED AT LEAST 6" BELOW ADJACENT FINISHED SURFACE BIORETENTION AREA DETAIL NOT TO SCALE PI/L PI/L I I I SECTION B -B: ALLEY IMPROVEMENTS NOT TO SCALE UtJIIaIVtU CST: UK8 UT: UHLUKLU CT: BENCHMARK AS -BUILT APPROVALS ENGINEERING DIVISION APPROVALS DESCRIPTION: 2.5" BRASS DISC IN THE INT. DATE PLANS PREPARED UNDER SUPERVISION OF RECD MENDE AP OVED: SOUTHEAST QUANDRANT OF LEUCADIA BLVD. AND ORPHEUS AVE. PER ROS 18416, AS PT PUBLIC WORKS DATE: Io 2N•1i NO. 1024 BRIAN ARDOLINO DATE RECORD FROM: PLANNING R.C.E. NO.: 71651 JESA OWENS EDWARD J. MER ELEVATION: IE 178.543 CITY ENG N R DATUM: NAVD88 SENIOR ENGINEER DATE REVIEWER BRIAN M. RD LINO �� y�� INSPECTOR EXP.: 12 -31 -19 DATE DAT PROPERTY LINE CENTER LINE EXISTING WATER LINE EXISTING SEWER LINE 398 - - - -- EXISTING CONTOUR LINE WANMOMINNEWAMM EXISTING STRUCTURE PROPOSED SETBACKS PROPOSED BUILDING FOOTPRINT PROPOSED DECKABOVE PROPOSED ROOF ABOVE + + + + + + PROPOSED PERMANENT BMPAREA ° PROPOSED CONCRETE PROPOSED AC PAVEMENT PROPOSED BASEMENT WALL 38 PROPOSED CONTOUR LINE PROPOSED RETAINING WALL PROPOSED STORM DRAIN INLET PROPOSED STORM DRAIN PROPOSED SO PUMP FS FINISHED SURFACE FG FINISHED GRADE FL FLOW LINE FF FINSHED FLOOR FYSB FRONT YARD SETBACK SYSB SIDE YARD SETBACK RYSB REAR YARD SETBACK TOP OF WALL (TW) BOTTOM OF WALL (BM TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOT TO SCALE IZQ I %C QRpf ESSlOy /V c0 CNAE( '< O o 0 z� rm No. 71651 om ¢Q Exp. 12/31/19 `0 ce m J J> CIV11 F OF CAS \F� Lu w S 10 5 0 10 20 30 p 1 hHod U N (n ¢I GRAPHIC SCALE IN FEET (L 0) iii N CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. z Lo GRADING PLAN FOR: 2139 MONTGOMERY AVENUE °z 14167 -G Z Z APN: 260 - 403 -06 w a 8 -114 DR p CDP SHEET 2 OF 8 PLSA 2832 PROPERTY LINE CENTER LINE EXISTING WATER LINE EXISTING SEWER LINE 398 - - - -- EXISTING CONTOUR LINE WANMOMINNEWAMM EXISTING STRUCTURE PROPOSED SETBACKS PROPOSED BUILDING FOOTPRINT PROPOSED DECKABOVE PROPOSED ROOF ABOVE + + + + + + PROPOSED PERMANENT BMPAREA ° PROPOSED CONCRETE PROPOSED AC PAVEMENT PROPOSED BASEMENT WALL 38 PROPOSED CONTOUR LINE PROPOSED RETAINING WALL PROPOSED STORM DRAIN INLET PROPOSED STORM DRAIN PROPOSED SO PUMP FS FINISHED SURFACE FG FINISHED GRADE FL FLOW LINE FF FINSHED FLOOR FYSB FRONT YARD SETBACK SYSB SIDE YARD SETBACK RYSB REAR YARD SETBACK TOP OF WALL (TW) BOTTOM OF WALL (BM TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOT TO SCALE IZQ I %C QRpf ESSlOy /V c0 CNAE( '< O o 0 z� rm No. 71651 om ¢Q Exp. 12/31/19 `0 ce m J J> CIV11 F OF CAS \F� Lu w S 10 5 0 10 20 30 p 1 hHod U N (n ¢I GRAPHIC SCALE IN FEET (L 0) iii N CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. z Lo GRADING PLAN FOR: 2139 MONTGOMERY AVENUE °z 14167 -G Z Z APN: 260 - 403 -06 w a 8 -114 DR p CDP SHEET 2 OF 8 PLSA 2832 TOP OF WALL (TW) BOTTOM OF WALL (BM TYPICAL WALL ELEVATION LOCATIONS SHOWN ON PLAN NOT TO SCALE IZQ I %C QRpf ESSlOy /V c0 CNAE( '< O o 0 z� rm No. 71651 om ¢Q Exp. 12/31/19 `0 ce m J J> CIV11 F OF CAS \F� Lu w S 10 5 0 10 20 30 p 1 hHod U N (n ¢I GRAPHIC SCALE IN FEET (L 0) iii N CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. z Lo GRADING PLAN FOR: 2139 MONTGOMERY AVENUE °z 14167 -G Z Z APN: 260 - 403 -06 w a 8 -114 DR p CDP SHEET 2 OF 8 PLSA 2832 cc u. Ull w W W iz co ' i ra ;;c. r, m r r I x 3 o -d I S S GRAVEL BAGS OVERLAP �nrr� r,nn RUNOFF WITH ENDS OVERLAPPED 1. SET POSTS AND EXCAVATE A 4 BY 4 IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS. 2. STAPLE EXTRA STRENGTH SILT FENCE TO THE POSTS. POSTS ARE TO BE SPACED CLOSER THAN STANDARD PRE - MANUFACTURED SILT FENCE PRODUCTS. 6 IN (15 CM) LEGEND - X X - PROPOSED SILT FENCE PROPOSED GRAVEL BAG BERM LANDSCAPE EFFICIENCY BMP NOTES: 1. ROUTINE INSPECTION TO GUARD AGAINST RUNOFF AND EROSION AND TO DETECT PLANT OR IRRIGATION SYSTEM FAILURE 2. REPLACEMENT OF DEAD DYING AND DISEASED VEGETATION 3. ERADICATION OF INVASIVE SPECIES 4. REPAIRING THE IRRIGATION SYSTEM AND ITS COMPONENTS WHEN REQUIRED 5. REPLENISHING MULCH AS NEEDED 6. SOILAMENDMENT WHEN NECESSARYTO SUPPORTAND MAINTAIN HEALTHY PLANT GROWTH 7. FERTILIZING, PRUNING AND WEEDING AND MAINTAINING TURF AREAS 8. MAINTENANCE TO AVOID OBSTRUCTION OF MOTORISTS VIEWS 9. OWNER WILL BE RESPONSIBLE FOR MAINTENANCE 10. USE OF A TIMING DEVISE TO RUN ALL IRRIGATION (W /BATTERY BACKUP) 11. MAINTAIN THE SYSTEM CONSISTENT WITH MAWA (MAX APPLIED WATER ALLOWANCE) 12. REPLACEMENT OF VEGETATION TO BE CONSISTENT WITH PLANTS "HYDROZON E" 13. MAINTAIN THE IRRIGATION SYSTEM TO NOT EXCEED MAWA (MAX APPLIED WATER ALLOWANCE) STORMWATER POLLU77ON CONTROL POST CONSTRUCTION BMP /IMP NOTES 1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREETAND /OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUTA PERMIT FROM THE CITY. 1 ALL IMPERVIOUSAREAS WITHIN THE SITE SHALL DRAIN TOAPPROVED BMP /IMP FACILITIES AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITYAND /OR THE TURF /LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, ORANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP /BMP. 6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THATA SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON - COMBUSTIBLE ROOF THAT WILL NOTALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY- APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. ADDITIONAL NOTES 1. EROSION CONTROL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, GRAVEL BAGS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE, MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS, PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE. 2. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (DCIA) SHALL BE ALLOWED. DCIA MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS, SUCH AS ROOF, ROOF DRAIN, DRIVEWAY, AND STREET. 3. ALL PARCELS ARE SUBJECT TO ARCHITECTURAL DESIGN GUIDELINES FOR FUTURE SINGLE- FAMILY RESIDENTIAL DEVELOPMENT. THESE GUIDELINES ARE AVAILABLE AT CITY HALL (505 S. VULCAN AVE, ENCINITAS, CA92024)AND ARE APPROVED AS PER PC RES. 2006 -27, ADJACENT PROPERTY DISTURBANCE NOTE ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPLICANT'S PROPERTY. IF ANY DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORK, A WRITTEN LETTER OF PERMISSION FROM THE ADJACENT PROPERTY OWNER MUST BE OBTAINED AND SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ADJACENT PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AND SUBMITTED TO THE CITY IS GROUNDS FOR A STOP-WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION IS OBTAINED. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT THOMAS SCHROEDER AT (619) 884 -3660, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAYARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKDAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. INLET PROTECTION DETAIL 3. ATTACH THE FILTER FABRIC TO 4. BACKFILLAND COMPACT THE THE POSTS AND EXTEND IT EXCAVATED SOIL. INTO THE TRENCH. NOTE; BIORETENTION BASINS SHALL BE EXCAVATED AND USED AS DESILTING BASINS DURING CONSTRUCTION. THE SILT TWO LAYERS OF GRAVEL BAGS ��) SHALL BE COMPLETELY REMOVEDAND THE BIORETENTION III I I ' FILTER FABRIC ��r( BASINS COMPLETED ONCE FINAL SITE STABILIZATION IS I I I ACHIEVED, PRIOR TO OCCUPANCYAND /OR FINAL. AEL q�! AV Ilk RUNOFF WITH BAGS SILT FENCE DETAIL m No. 71651 IT 0 zz Exp. 12/31/19 GAP BETWEEN BAGS { S� 10 5 0 10 20 30 ACTS AS SPILLWAY GRAVEL BAG DETAIL sTgTF OF CAL�F��\P F s GRAPHIC SCALE IN FEET CHANGE NO DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIBMA BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. DESCRIPTION: 2.5" BRASS DISC IN THE INT. DATE PLANS PR RED UNDER SUPERVISION OF RECOMMEND APP OVED: EROSION CONTROL PLAN FOR: SOUTHEAST QUANDRANT OF LEUCADIA BLVD. PUBLIC WORKS DATE: to-EA-0t AND ORPHEUS AVE. PER ROS 18416, AS PT „i 2139 MONTGOMERY AVENUE NO. 1024 BRIAN ARDOLINO DATE 14167 -G RECORD FROM: PLANNING R.C.E. NO.: 71657 JE E OWENS EDWARD J. MER CITY ENG ELEVATION: IE 178.543 SENIOR ENGINEER DATE REVIEWER BRIAN M. ARDOLI // / ll� /9 Za� APN: 260- 403 -08 DATUM: Nei D88 INSPECTOR EXP.: 12 -31 -19 DATE DA 18 -114 DR CDP SHEET 3 OF 8 PLSA 2832 OQ U) �Q Q� U O �O � J QQ on �Q uw Q O� �U) N z� �O Wz ZW ?3 wa r TO BE 4-PLACE 0 EXISTING EDGE OF PAVEMENT" CUT a.. CUT LINE c� a i L PROPOSED ; x i _T1 =J 1` 1 �1 1 Qg I 04._1 °Glv, RIGHT -OF -WAY m i Z a m 4 A! Tin (2%) 103.27 u S 031, 79 E ;._, a nn` .tROPOSEDWOODf IPT EXISTING 2 STORY RESIDENCE 1' #1' 1 °;1"t °t; C 7„# E ED ' d B I ; � PROPOSED AND �I R T . , (n EXISTING 1 -STORY RESIDENCE t LOCAT ON WITH SDG c QE 1i « 1 s/ 1 3 7 1« o wT . .: �-� = 4I. W 112,3 13,35 BHI k . S { � jV p 321 8 ( ! 1 PROPERTY LINE �,r £ J iPROT ,...,) � � s d"�° A 9 E g 67- aI .p f'ry qq g ,�q (yA�ti _ — 7 in L - — S t .4y WTI f .: / ,ate __ , - -- .fz,.', F:,�i`tf t` ,..,.? s !., ( d . did'@ -. i r l V" i" / 9 ,, ;, ,. l! , s^�,. el/ r` ;'., -/j7 "'yes.., ,i a ,;l .L /,{ ;i /% 'P 4 W Y ( 7, PROPOSED TEMPORARY SHORING . J . A k, Y ,I I I TYPICAL SEE SHEETS 5 I I r - ?. ' -- - - - - -- - -- - r / I x I. F1 U, -_ -- r L - � UNIT 1 PROPOSED BASEMENT - -- -- - - - - �'� � III a ���.. � ',` i - -- - - - - -- - -- - - �_ n n. _ ' L _ 7 72 g''. OD u� is x 4 =65 F1 .,. Gr =' �J r b ,# t �r • ✓ z 7 TEMPORARY 1 -1 SLOPE (BY OTHERS, TYPICAL) 0 # 1 6F 110-86 F , T .1 . J RIGHT( 0 WAY I L- - - - - -- -- - - - - -- UNIT 2 PROPOSED BASEMENT = I 04,23 FS 7L - -4 LID � n U) l 3 i 93 EX 1(04,25 __ L a - - I �i — ; 09,69 1E } vc, PROPOSED TEMPORARY SHORING - c j Tat1 (TYPICAL, SEE SHEET SH6) ; ri �r _ 4 F�L - # >'«i A€ 0 ` - - 51 moo, o L, -- -- - - - -- - - -� -- - - M - - - -�'1 (E) MONUMENTTO BE DESIGN. CRITERIA 1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED IN THE FOLLOWING GEOTECHNICAL REPORT(S): A. PRELIMINARY GEOTECHNICAL INVESTIGATION a FOUNDATION RECOMMENDATIONS PROPOSED NEW TWIN HOMES TO BE LOCATED AT 2139 -2141 MONTGOMERY AVENUE CARDIFF -BY- THE -SEA, CALIFORNIA PREPARED BY: ENGINEERING DESIGN GROUP DATED: DECEMBER 4, 2018 2. SOIL DESIGN PRESSURES A. ALLOWABLE PASSIVE EARTH PRESSURE = 350PSF /FT (8,000PSF MAX) B. LATERAL EARTH PRESSURE: = 35PSF /FT C. MINIMUM LIVE LOAD SURCHARGE = 72PSF E. BUILDING SURCHARGE = 700PLF (LATERAL LINE LOAD) CHANGE NO I DESCRIPTION I APPROVED I DATE PLOT DATE• t5" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS A�E. PER ROS 18416, AS PT NO 1024 RECORDED FROM ELEVATION: 17 &543 DATUM: NAVD 88 A S-BUIL T A PPRO VA L S INT. I DATE I PLANS PREPARED UNDER SUPERVISION OF PUBLIC WYJRKS PLANNING REVIEWER a nc _ v ! -,:•C; 9 � ? .rs 5 "6., s// u"xy u;; _t..y_ «. ' %. :�" i^y;.' �, ,: 1: —.-�� y , , , % 11 i }���� ✓"�"`� $ � x 1t I I L �� 8 1 1� 5--- 7 72 g''. OD u� is x 4 =65 F1 .,. Gr =' �J r b ,# t �r • ✓ z 7 TEMPORARY 1 -1 SLOPE (BY OTHERS, TYPICAL) 0 # 1 6F 110-86 F , T .1 . J RIGHT( 0 WAY I L- - - - - -- -- - - - - -- UNIT 2 PROPOSED BASEMENT = I 04,23 FS 7L - -4 LID � n U) l 3 i 93 EX 1(04,25 __ L a - - I �i — ; 09,69 1E } vc, PROPOSED TEMPORARY SHORING - c j Tat1 (TYPICAL, SEE SHEET SH6) ; ri �r _ 4 F�L - # >'«i A€ 0 ` - - 51 moo, o L, -- -- - - - -- - - -� -- - - M - - - -�'1 (E) MONUMENTTO BE DESIGN. CRITERIA 1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED IN THE FOLLOWING GEOTECHNICAL REPORT(S): A. PRELIMINARY GEOTECHNICAL INVESTIGATION a FOUNDATION RECOMMENDATIONS PROPOSED NEW TWIN HOMES TO BE LOCATED AT 2139 -2141 MONTGOMERY AVENUE CARDIFF -BY- THE -SEA, CALIFORNIA PREPARED BY: ENGINEERING DESIGN GROUP DATED: DECEMBER 4, 2018 2. SOIL DESIGN PRESSURES A. ALLOWABLE PASSIVE EARTH PRESSURE = 350PSF /FT (8,000PSF MAX) B. LATERAL EARTH PRESSURE: = 35PSF /FT C. MINIMUM LIVE LOAD SURCHARGE = 72PSF E. BUILDING SURCHARGE = 700PLF (LATERAL LINE LOAD) CHANGE NO I DESCRIPTION I APPROVED I DATE PLOT DATE• t5" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS A�E. PER ROS 18416, AS PT NO 1024 RECORDED FROM ELEVATION: 17 &543 DATUM: NAVD 88 A S-BUIL T A PPRO VA L S INT. I DATE I PLANS PREPARED UNDER SUPERVISION OF PUBLIC WYJRKS PLANNING REVIEWER a nc 5TJZVCTL*CAe_ V_EV16k/ ?dRPbRM" $Y 6.TG/l., A sA&w0u1t r campAAIY AS ?LA,%I CHECK I°I -1658 0A7" 8/1 /l a . DATE: I°I R.C.E. NO.: 80503 EXP. 3/31 21 ENGINEERING DIVISION A PPRO VA L S RECOM LADED: �io OWENS EDWARD J. tMMB /i1-4 A i I 1 I9 DAZE DAIS Know what's below. Call before you dig. ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT Et GENERAL CONTRACTOR SHALL LOCATE Et POTHOLE (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL CONSTRUCTION BEGINS. STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH EXCAVATION PERMIT NO TRENCH /EXCAV _________ IMPROVEMENT TEMPORARY SOLDIER BEAM TEMPORARY TIMBER LAGGING SOLDIER BEAM COUNT DETAIL /SECTION CALLOUTS 3x12 DF #2 TIMBER LAGGING 0 4 a 6 E 3131/21 SCALE:1 " =16/' F L CITY OFENCINITAS -DEVELOPMENT SERVICES DEPARTMENT (,WADING PLAN FOR 1139 MONTGOMERYA VENUE APN.' 157.040 -16 SYMBOL I m 7755 VIA FRANCESCO #1 SAN DIEGO, CA 92129, (760)586 -8121 DRAWING NO _ OE y _- % 11 {j��p%� }���� ✓"�"`� $ -30a, PROPOSED 0C 8 OE 1° , 1 d CC 5TJZVCTL*CAe_ V_EV16k/ ?dRPbRM" $Y 6.TG/l., A sA&w0u1t r campAAIY AS ?LA,%I CHECK I°I -1658 0A7" 8/1 /l a . DATE: I°I R.C.E. NO.: 80503 EXP. 3/31 21 ENGINEERING DIVISION A PPRO VA L S RECOM LADED: �io OWENS EDWARD J. tMMB /i1-4 A i I 1 I9 DAZE DAIS Know what's below. Call before you dig. ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT Et GENERAL CONTRACTOR SHALL LOCATE Et POTHOLE (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL CONSTRUCTION BEGINS. STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH EXCAVATION PERMIT NO TRENCH /EXCAV _________ IMPROVEMENT TEMPORARY SOLDIER BEAM TEMPORARY TIMBER LAGGING SOLDIER BEAM COUNT DETAIL /SECTION CALLOUTS 3x12 DF #2 TIMBER LAGGING 0 4 a 6 E 3131/21 SCALE:1 " =16/' F L CITY OFENCINITAS -DEVELOPMENT SERVICES DEPARTMENT (,WADING PLAN FOR 1139 MONTGOMERYA VENUE APN.' 157.040 -16 SYMBOL I m 7755 VIA FRANCESCO #1 SAN DIEGO, CA 92129, (760)586 -8121 DRAWING NO 110.00' NOTES: 1. SEE SOLDIER BEAM SCHEDULE ON SHEET SH8 FOR SHORING ATTRIBUTES. 2. POTHOLE /FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. 3. THE GENERAL CONTRACTOR (UPON COMPLETION OF SITE DEMO WORK) SHALL FIELD VERIFY NEIGHBORING RETAINED GRADES TO CONFIRM THE EXTENT OF SHORING SHOWN. NOTIFY SHORING ENGINEER OF RECORD PRIOR THE BEAM FABRICATION AND INSTALLATION. EXISTING -- EDGE O 10327"'1'—'- \ r� \ t I )RArW ' `- E "E`N RIGHT -OF -WAY T.O.W. = 107.00' B.O.W.= 103.00' —I �J SB #1 EXISTING GRADE ALONG ADJACENT PROPERTY T T 1 T.Q.W. = 108.00' 5 9 SPACES @ 8' -0" O.C. = 72' -0" - 3.9 SIM 1). 1 n.• SH7 . T.O. W. = 113.00' LOWER GRADES TO MATCH NEIGHBORING ELEVATIONS AFTER EXISTING RETAINING WALL IS REMOVED (FIELD VERIFY) T.O. W. = 113.00- i.7.=— • • Ifl } I PROP( (SEE C CHANCE N0. DESCRIPTION APPROVED DATE BENCHMARK 25" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS AVE PER ROS 18416, AS PT NO 1024 RECORDED fROM.- f1EVA1TON: 178.543 DA MY: NA VD 88 PROFILE - LOOKING NORTH SCALE: 1" = 16/3' EXISTING 2 -STORY RESIDENCE " 6 f w.ti! 1 r 10 1_ -- i- d g �r 1 1` Z, 2.. 2'-6" MIN. .:v - ;ct - ;,� U 16 ;. _ L�, , 2 _ 1.r _ �i' §9.69 1E SH7 SH7 -- - - - -- +- - - - - -- SH7 �' - -- ------ - - - - -- �. u` SH7 r -- — J L- -- - - - - -J UNIT 1 PROPOSED BASEMENT lu I 2 c > -- 8 - - - - - -- r - - -� I I I I r n t AS BUILTAPPROVALS INT DATE I PLANS PREPARED UNDER SUPEWSION OF PUBLIC tYORKS PLANNING REVIEWER I,rf 1 crromccrt UAIL I INSPECTOR I 1 1 ENGINEER OF WORK PLOT DATE.- 611812019 DATE: 1- " R.C.E. N0.: 8050J EXP. JIJ1 121 LEGEND: T.O.W. = TOP OF WALL B.O.W. = BOTTOM OF WALL - -- DESIGNATES 3x12 PRESSURE - - - - - -- -— - -- TREATED TIMBER LAGGING p j , < y t: i E pY (Y fr 43 d .i�id L' 174 a e TMk w 1 ^` CAUTION!!! EXISTING OVERHEAD POWER r �i V ow TEMPORARY 1 -1 SLOPE I (BY OTHERS, TYPICAL) k' Y RIGHT-OF-WAY l< =_ s I . a _19.31 v °Fri % 0 4 8 16 SCALE:1 " =16/3' ENGINEERING DIVISION A PPRO VA L S RECOMM LADED: AP A KNS EDWARD /J. WTMME DATE //��LL'l DA7 r I -%19 CITY OFENCINITA8 - DEVELOPMENT SERVICES DEPARTMENT FOR.- 1139 MONTGOMERY VENUE APN.• 15704046 110.00'1 7755 VIA FRANCESCO #1 SAN DIEGO, CA 92129, (760)586 -8121 DRAWING N0. 14161- 110.00' NOTES: 1. SEE SOLDIER BEAM SCHEDULE ON SHEET SH8 FOR SHORING ATTRIBUTES. 2. POTHOLE /FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. 3. THE GENERAL CONTRACTOR (UPON COMPLETION OF SITE DEMO WORK) SHALL FIELD VERIFY NEIGHBORING RETAINED GRADES TO CONFIRM THE EXTENT OF SHORING SHOWN. NOTIFY SHORING ENGINEER OF RECORD PRIOR THE BEAM FABRICATION AND INSTALLATION. T co NIVYV 3 em; - - -- -- 9 SPACES @ 8' -0" O.C. = 72' -0" - T -0" FREE 7 (SHIM LAGGING) EXISTING GRADE ALONG T.O.W. = 117.00' — ADJACENT PROPERTY r -- T.O.W. = 114.4�4 6 5 4 3.9 3 W. = 112.00' ESH7 B.O.W.= 112.00' -I ) I - TO.W. =1 1.00' i 1 EXISTING RETAINING WALL - (TO BE REMOVED PRIOR TO SHORING INSTALLATION) Mg 0'6t t f 3 SH7 TYP. t LJ SB #11 1 I t r H" I - B.O.W. - 101.00'i' ik,4 B.O.W II 99.00' II ICI I i L "J SB #19 SB #18 SB #17 I�- ICI 111% ICI II ICI LJ 3 L �J SB #15 SB #14 I t r H" I .- W.- PROFILE - LOOKING SOUTH SCALE: 1" = 16/3' 2.1 2 1 T.O.W. 90 .00' 1 _ _ �I OW. 00 t T.O.W. = 106.00' R -W- = 102 -00' g r' 6 ) LEGEND: T.O.W. = TOP OF WALL B.O.W. = BOTTOM OF WALL -- -- - - - - -- DESIGNATES 3x12 PRESSURE - -- — - -- - - - -- TREATED TIMBER LAGGING 110.00' PLOT DA 7E.- ik,4 L "J SB #19 SB #18 SB #17 r' 6 ) LEGEND: T.O.W. = TOP OF WALL B.O.W. = BOTTOM OF WALL -- -- - - - - -- DESIGNATES 3x12 PRESSURE - -- — - -- - - - -- TREATED TIMBER LAGGING 110.00' PLOT DA 7E.- SAFETY CABLE RAILING, PER CAL -OHSA REQUIREMENTS (TYP., AROUND ENTIRE SHORED PERIMETER, SEE 8 /SH7) PAD ELEVATION ,.H,. e 42" (MIN.) EXISTING GRADE TIMBER LAGGING, TYPICAL (SEE ELEVATION FOR SIZE) 5 SACK SLURRY SHAFT kCKFILL (T.O.W. TO B.O.W) 2,500 PSI CONCRETE SHAFT BACKFILL (B.O.W TO PILE TIP) SOLDIER BEAM (SEE SCHEDULE FOR SIZE) NOTES: 1. FIELD VERIFY ALL EXISTING Ft PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. LAGGING ABOUT THE LOWER 2' -0" OF EXCAVATION MAY BE OMITTED WITH APPROVAL FROM THE GEOTECHNICAL ENGINEER OF RECORD (CONTRACTOR SHALL ASSES Et SUBMIT FOR APPROVAL). 3. SEE SOLDIER BEAM SCHEDULE ON SH8 FOR VARIABLES "H ", "D ", Et "Dshaft ". 1 TEMPORARY CANTILEVERED SOLDIER BEAM (TYP.) �l N.T.S. 0 10'-0 "± T -O" 2' -6" 110.00' (E) GRADE „H„ PROPOSED PAD (SEE CIVIL DWG)--- ,.D„ 90.00' ' (E) 1 -STORY RESIDENCE 110.00' BACK LAG AT (E) WALL DEMO (AS REQUIRED) _ 1001_90'. (E) RETAINING WALL (TO BE REMOVED) SOLDIER BEAM 90.00' NOTES: 1. FIELD VERIFY ALL EXISTING Et PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. SEE SOLDIER BEAM SCHEDULE ON SHEET SH8 FOR VARIABLES "H" Et "D ". 3. THE GENERAL CONTRACTOR SHALL PROPERLY REMOVE EXISTING RETAINING WALLS ALONG ADJACENT PROPERTY LINES PRIOR TO SHORING INSTALLATION AND FABRICATION. SOLDIER BEAM CROSS SECTION ALONG NORTHERN PROPERTY LINE N.T.S. SOLDIER BEAM DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL MATERIAL) SOLDIER BEAM / I I I SEE ELEVATION FOR SPACING FILL VOIDS BEHIND LAGGING WITH LEAN CONCRETE TIMBER LAGGING (SEE ELEVATIONS) SOLDIER BEAM PLAN DETAIL (TYPICAL) N.T.S. SEE ELEVATION FOR SPACING FILL VOIDS BEHIND LAGGING WITH LEAN CONCRETE DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL MATERIAL) 20d COMMON NAIL FOR LAGGING INSTALLATION (TYP., AS REQ'D) 20d COMMON NAIL FOR LAGGING INSTALLATION (TYP., AS REQ'D) / \ TIMBER LAGGING 11.5" (MIN.) (SEE ELEVATIONS) \ / BEARING BACK SOLDIER BEAM PLAN DETAIL (AS REQUIRED) N.T.S. PROPERTY LINE T -0" i 2' -10" 110.00' . (E) GRADE .,H., 10Q,_00' PROPOSED PAD _ - -- (SEE CIVIL DWG) 1l'-6" .; (E) 2 -STORY RESIDENCE 110.00' PROPOSED RETAINING WALL (SEE CIVIL DRAWINGS) _ (E) RETAINING WALL 100.00' (TO BE REMOVED) — SOLDIER BEAM NOTES: 1. FIELD VERIFY ALL EXISTING Et PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. SEE SOLDIER BEAM SCHEDULE ON SHEET SH8 FOR VARIABLES "H" Et "D ". 3. THE GENERAL CONTRACTOR SHALL PROPERLY REMOVE EXISTING RETAINING WALLS ALONG ADJACENT PROPERTY LINES PRIOR TO SHORING INSTALLATION AND FABRICATION. SOLDIER BEAM CROSS SECTION ALONG SOUTHERN PROPERTY LINE N.T.S. TIMBER LAGGING (SEE ELEVATION) TIMBER LAGGING �� ���SOLDIER BEAM ra SEE ELEVATION TIMBER LAGGING 1' (SEE ELEVATION) I COMMON NAIL FOR LAGGING (I - - INSTALLATION (4 PER BOARD) TIMBER LAGGING DIAGONAL SUPPORT DETAIL 10% N.T.S. _. P. (TYP) NOTES: 1. REFER TO AWS D1.1 PREQUALIFIED WELD DETAIL FOR SPECIFICATIONS. 2. NO CHEMICAL TESTING REQUIRED FOR TEMPORARY WELD APPLICATION. FULL PENETRATION SPLICE DETAIL (AS REQUIRED) L2x2x3/8 ANGLE IRON ATOP - EACH SOLDIER BEAM MEMBER 3/8 -inch 0 WIRE ROPE - ALONG ENTIRE SHORING PERIMETER (TYP.) SOLDIER BEAM, TYP. (SEE SCHEDULE) N.T.S. oil 21" 44" 21" H7) N.T.S. L =6" EACH BEAM DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL MATERIAL) 1 IV1 \Q 7755 VIA FRANCESCO #1 F A� SAN DIEGO, CA 92129, (760)586 -8121 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS- BUILTAPPROVALS DESIGNED BY DRAWN BY CHECKED BY ENGINEER /NGD/V/S/ONAPPROVALS C /TYOfENC /N /TAS- DEVELOPMENT SERVICES DEPARTMENT DRA WING NO, 'yH /H RR 15" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS AVE.. PER ROS 18416, AS PT NO 1014 RECORDED FROM.• ELEVATION: 178.543 DATUM: IVAVD 88 INT DATE PLANS PREPARED UNDER SUPERVISION OF DATE : 10 -Z4- I Y R.C.E. NO.: 80503 REED 3 f3t 11 ENGINEER OF WORK EXP. RECDMME DED: A p D, ` +vd. JESSE AIS DWARD J. WiMMER � i 19 DATE �1! x DATE GRADING PLAN FOR: 20 MONTGOMERYA VENUE APN,' 257-040-16 18 -114 DR // CDP _ '4167 -G PUBLIC WORKS ROY PLANNING REVIEWER SHEET 7 OF 8 CITY FNrINFFR DATE 1AITFUR PLOT DATE.• 1. CONSTRUCTION PLANS AND CALCULATIONS CONFORM TO THE REQUIREMENTS OF THE 2016 CALIFORNIA BUILDING CODE. 2. TEMPORARY SHORING CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE OF CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL - OSHA). 3. HEAVY CONSTRUCTION LOADS SUCH AS CRANES, CONCRETE TRUCKS OR OTHER LOAD SURCHARGES NOT IDENTIFIED IN THE "DESIGN CkiTERIA ", WILL REQUIRE ADDITIONAL ANALYSIS Et FURTHER RECOMMENDATIONS. NOTIFY THE SHORING Et SOILS ENGINEER. 4. ALL TEMPORARY SHORING ELEMENTS DEPICTED WITHIN THESE DRAWINGS ARE LIMITED TO A MAXIMUM SERVICE LIFE OF ONE (1) YEAR. AT THE END OF THE CONSTRUCTION PERIOD, THE EXISTING OR NEW STRUCTURES SHALL NOT RELY ON THE TEMPORARY SHORING FOR SUPPORT IN ANYWAY. 5. AN UNDERGROUND SERVICE ALERT MUST BE OBTAINED 2 DAYS BEFORE COMMENCING ANY EXCAVATION. 6. THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS DURING CONSTRUCTION. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL INSPECTION SERVICES, TESTING Et NOTIFICATIONS. 8. ALL PERMITS SHALL BE PROCURED AND PAID FOR BY THE OWNER OR GENERAL CONTRACTOR. 9. ALL MONITORING PROVIDED IN THESE PLANS HEREIN, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. TEMPORARY SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING Et PROPOSED FEATURES, AS PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL CONTROL Et COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY VARIATIONS TO THE ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK. 11. THE GENERAL CONTRACTOR OR OWNER SHALL LOCATE ALL EXISTING UTILITIES AND STRUCTURES PRIOR TO EXCAVATION AND THE INSTALLATION OF SHORING. 12. THE GEOTECHNICAL ENGINEER OF RECORD SHALL REVIEW Et VERIFY THAT THE PROPOSED TEMPORARY SHORING, CONFORMS TO THE SPECIFICATIONS OF THE APPROVED SOILS REPORT, 13. THE GENERAL CONTRACTOR SHALL CONFIRM THAT THE PROPOSED SHORING DOES NOT CONFLICT WITH FUTURE IMPROVEMENTS PRIOR TO INSTALLATION. 14. THE GENERAL CONTRACTOR SHALL PROVIDE MEANS TO PREVENT SURFACE WATER FROM ENTERING THE EXCAVATION OVER THE TOP OF SHORING BULKHEAD. 15. INSTALLATION OF SHORING AND EXCAVATION SHALL BE PERFORMED UNDER CONTINUOUS OBSERVATION AND APPROVAL OF THE GEOTECHNICAL ENGINEER AND AUTHORITY HAVING JURISDICTION. 16. ALTERNATIVE SHAPES, MATERIAL AND DETAILS CANNOT BE USED UNLESS REVIEWED AND APPROVED BY THE SHORING ENGINEER. 17. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFY CONDITIONS AT THE JOB SITE AND TO CROSS -CHECK DETAILS AND DIMENSIONS WITHIN THE SHORING PLANS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER PERTINENT DRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. SHORING INSTALLATION PROCEDURE 1. FIELD S;;gVEY DRILL HOLES 8t SHORING ALIGNMENT ACCORDING TO WALL DIMENSIONS Et DATA SHOWN OR AS APPROVED BY THE SHORING ENGINEER. 2. DRILL VERTICAL SHAFTS TO THE EMBEDMENT DEPTH AND DIAMETERS SHOWN. ALLOWABLE PLACEMENT TOLERANCE SHALL BE 2" IN OR 2" OUT OR AS OTHERWISE AUTHORIZED BY THE SHORING ENGINEER. 3. INSTALL SOLDIER BEAMS ACCORDING TO THE DETAILS Et SPECIFICATIONS SHOWN IN PLAN. IF NECESSARY, CASING OR OTHER METHODS SHALL BE USED TO PREVENT LOSS OF GROUND OR COLLAPSE OF THE HOLE. 4. START EXCAVATION AFTER CONCRETE HAS CURED FOR A MINIMUM OF (3) THREE DAYS. 5. INSTALL LAGGING BETWEEN INSTALLED SOLDIER BEAMS IN LIFTS NO GREATER THAN 4' -0" OR AS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. 6. BACKFILL ALL VOIDS BEHIND LAGGING WITH COMPACTED SOIL OR LEAN CONCRETE AS SPECIFIED IN THE DETAILS HEREIN. 7. REPEAT STEPS 5 -6 UNTIL BOTTOM OF EXCAVATION IS REACHED. STRUCTURALSTEEL 1. STRUCTURAL STEEL (WIDE FLANGES) SHALL CONFORM TO THE REQUIREMENTS ASTM A -572 OR ASTM A -992 (GRADE 50). OEAM3 SAAI.L 14 GALVAMIzZO oR 6PoxY C*^ -rob . 2. MISCELLANEOUS STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A -36, ASTM A -572 (GRADE 50) OR ASTM A -992. 3. TRENCH PLATES (LAGGING) SHALL CONFORM TO THE REQUIREMENTS FO ASTM A -36. 4. WIRE ROPE (GUARDRAIL): SHALL HAVE A MINIMUM BREAKING STRENGTH OF 13,500LBS. STRUCTURAL S: LEAN CONCRETE A. STRUCTURAL CONCRETE: 1. STRUCTURAL CONCRETE (DRILL SHAFT TOE BACKFILL) SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,50OPSI AT 28 -DAYS. 2. CONCRETE MIX SHALL BE IN ACCORDANCE WITH 2O16CBC Et ACI 318 TO MEET THE FOLLOWING: A. MAXIMUM 1 -INCH HARDROCK CONCRETE CONFORMING TO ASTM C -33. B. TYPE II NEAT PORTLAND CEMENT CONFORMING TO ASTM C -150. C. SLUMP NO GREATER THAN 5- INCHES. B. LEAN CONCRETE (SLURRY) 1. LEAN SAND SLURRY MIX SHALL CONTAIN A MINIMUM OF 1.5 SACKS TYPE II CEMENT PER CUBIC YARD. TIMBER 1. TIMBER LAGGING SHALL BE ROUGH SAWN DOUGLAS FIR LARCH NO. 2 OR BETTER. 2. TIMBER LAGGING SHALL BE PRESSURE TREATED FOR GROUND CONTACT IN ACCORDANCE WITH AWPA U1 USE CATEGORY 4A. WELDING 1. ELECTRIC ARC WELDING PERFORMED BY QUALIFIED WELDERS USING E70XX ELECTRODES OR CONTIUOUS WIRE FEED. 2. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. SOLDIER BEAM SCHEDULE 1 1 W12x26 2. Inspection of concrete placement for Toe Maximum Toe Total From To Beam Beam Shored Depth Drill Diameter 2 Beam : Beam Qty Section Height Depth 9.0 13.0 H D H +D Dshaft 5 ft ft ft in 10.0 _ .1 1 1 W12x26 2. Inspection of concrete placement for 5.0 10.0 15.0 24 2 3 2 W 16 x 36 : 9.0 13.0 22.0 24 4 5 2 W 16 x 40 ' 10.0 14.0 24.0 24 6 6 '_ 1 W 18 x 50 11.0 14.0 25.0 24 7 8 1 2 W 18 x 60 ' 12.0 15.0 27.0 24 9 9 i_ 1 W 18x 50 11.0 14.0 25,0 24 10 10 1 W12x26 5.0 10.0 15.0 24 11 11 1 W 12 x 26 5.0 15.0 20.0 _ 24 12 12 1 W 18 x 71 15.0 17.0 32.0 24 13 14 ._ 2 _ W 18x71. 13.0 17.0 30.0 24_ 15 16 2 W 18 x 60 12.0 15.0 27.0 24 17 17 1 W 16 x 40 : 10.0 14.0 i 24.0 24 18 18 1 W 16 x 36 9.0 13.0 22.0 24 19 19 1 W 14 x 30 8.0 12.0 20,0 24 20 20 1 W 12 x 26 5.0 10.0 15.0 24 STATEMENT OF SPECIAL INSPECTIONS VERIFICATION AND INSPECTION CONTINOUS PERIODIC CBC REFERENCE 1. Verify use of required design mix CHANGE N0. X 1904.2.2 2. Inspection of concrete placement for BENCHMARK X DfS /GRAD 8Y proper application techniques. CHECKED BY ENGINEERINGDIVISIONAPPROVALS CI TYOFENCI NITAS- DEVELOPMENTSERVICESDEPARTMENT 3. Material verification of structural steel a. For structural steel, identification X markings to conform to AISC 360. INT. b. Manufacturer's report PLANS PREPARED UNDER SUPERVISION OF DA7F Io -2�(� I DA R.C.E. N0.: 80503 Y P. REED ENGINEER OF WORK EXP. 3131121 X GRADING PLAN FOR: 1139MONTGOMERYAVENUE APN, 257- 040 -16 ta_im nA 11 rno 4. Inspection of welding a. Multipass fillet welds X 2303.1.8.1 5. Material identification of timber a. Identification of preservative PLANNING X VERIFICATION AND INSPECTION ITEMS (OTHER) 6. Observe drilling operations and maintain complete and accurate X records for each element. CITY ENG#M DA TE 7. Verify placement locations and curer Q /1C A plumbness, confirm element diameters, lengths, embedment into X bedrock (if applicable). Record concrete and grout values. 8. Verify excavations are extended to the proper depth. X SPECIAL INSPECTION REPORT PREPARED BY: DATED . ON FILE WITH ENGINEERING DIVISION. 1. MONITORING SHAI.L BE ESTABLISHED AT THE TOP OF SOLDIER BEAMS SELECTED BY THE ONSITE GEOTECHNCIAL REPRESENTATIVE AND AT INTERVALS ALONG THE WALL AS CONSIDERED APPROPRIATE. 2. THE GENERAL CONTRACTOR SHALL PERFORM A PRECONSTRUCTION SURVEY INCLUDING PHOTOGRAPHS Et VIDEO OF THE EXISTING SITE --ONDITIONS. BASELINE SURVEY DATA TO BE SUBMITTED TO CITY LAND SURVEYOR. 3. MONITORING SHALL BE PERFORMED AFTER ROUGH GRADING, ANY SIGNIFICANT STORM OR SEISMIC EVENT AND AT THE TERMINUS OF THE PROJECT. FINAL MONITORING REPORT SHALL BE SUBMITTED TO CITY LAND SURVEYOR PRIOR TO OCCUPANCY. 4. MAXIMUM THEORETICAL SOLDIER BEAM DEFLECTION IS 0.75 -INCH. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) EXCEEDS THIS LIMIT, ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED AND INVESTIGATED BY THE SHORING ENGINEER FOR FURTHER ACTIONS (AS NECESSARY). 7755 VIA FRANCESCO #1 OF SAN DIEGO, CA 92129, (760)586 -8121 CHANGE N0. DESCRIPflON APPROVED DATE BENCHMARK AS- BUILTAPPROVALS DfS /GRAD 8Y DRAB BY CHECKED BY ENGINEERINGDIVISIONAPPROVALS CI TYOFENCI NITAS- DEVELOPMENTSERVICESDEPARTMENT DRAWING NO. 2.5" BRASS DISC IN THE SOUTHEAST QUADRANT OF LEUCADIA BLVD. AND ORPHEUS AVE PER ROS 18416, AS PT NO 1024 RECORDED fROM ELEVATION: 178.543 DATUM: N4 VV 88 INT. DATE PLANS PREPARED UNDER SUPERVISION OF DA7F Io -2�(� I DA R.C.E. N0.: 80503 Y P. REED ENGINEER OF WORK EXP. 3131121 RECOM LADED: ED: JES OWENS EDWARD J. YAMd // /9 l l 9 s o DAB DATE GRADING PLAN FOR: 1139MONTGOMERYAVENUE APN, 257- 040 -16 ta_im nA 11 rno 14167 -G PUBLIC WORKS DA TE PLANNING REVIEWER CITY ENG#M DA TE INSPFCTOR curer Q /1C A PLOT DATE.• 611812019