2018-13717 G (Plans)RIGHT OF WAY NOTE
OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS
PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP
WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS /HER
PROPERTY LINE IS.
DRAINAGE NOTE
NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN
AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED
DRAINAGE FACILITY.
UTILITY NOTE
ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC
WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN
DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED
BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION.
2. THE SOILS REPORT TITLED "LIMITED GEOTECHNICAL INVESTIGATION AND INFILTRATION TESTING FOR
PROPOSED IMPROVEMENTS AT THE TURNER RESIDENCE" PREPARED BY CONSTRUCTION TESTING &
ENGINEERING, INC. DATED 11- 27 -17, PROJECT# 10- 14005G SHALL BE CONSIDERED AS A PART OF THIS GRADING
PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS
CONTAINED IN SAID REPORT.
3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY OR
EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS.
4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING.
5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES
DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO
CONDITION EXISTING PRIOR TO GRADING.
6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR
DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED
LAND SURVEYOR.
7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING,
AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH
STANDARDS, LAWS AND REGULATIONS.
8. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (112) MILE OF A STRUCTURE FOR HUMAN
OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATURDAYS,
SUNDAYS AND CITY RECOGNIZED HOLIDAYS.
9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE - CONSTRUCTION MEETING HAS BEEN HELD ONSITE
WITH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING
CONTRACTOR AND PERMITTEE. THE PRE - CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT
LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633 -2770.
10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN
THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE
PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY
ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION.
11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING
APPROVAL AND /OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED
STATING: "THE GRADING UNDER PERMIT NO. 13717 -G HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE
WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT
SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING
OPERATION.
12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION
HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND
COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE
SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT
OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL
EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE.
13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE
AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING
PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF
FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES
HAVE BEEN INSTALLED.
14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE
WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED
BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL
SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO
A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH
SPECIFICATIONS.
15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND
UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND
TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL
STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE
LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES
SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE.
16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR
OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN
CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION
OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL
OF ANY SUCH MATERIAL.
17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST
MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY PROPERTY, OR WITHIN
CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING
CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE
OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE
TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY
TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED IN PLACE. EVEN IF APPROVED
IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED
TO ADDRESS THE TREE REMOVAL.
EROSION CONTROL
1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT RICHARD TURNER AT (619) 890 -0034,
24 HOURS A DAY.
2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES
DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE
STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID
CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT.
3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE
ENGINEERING INSPECTOR,
4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO
THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL.
5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE
REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN
CIRCUMSTANCES WHICH MAY ARISE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO
PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE.
7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE
INCORPORATED HEREON.
8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF
SLOPE AT THE CONCLUSION OF EACH WORK DAY.
9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH
WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT
(40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL.
STORMWATER POLLUTION CONTROL POST CONSTRUCTION BMP /IMP NOTES
1. FOR STORM WATER POLLUTION CONTROL PURPOSES, ALL RUNOFF FROM ALL IMPERVIOUS
SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS
PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM
DRAIN SYSTEM.
2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL
NOT BE MODIFIED WITHOUT PERMIT FROM THE CITY.
3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP /IMP FACILITIES
AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE
FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMPAMP FACILITY
AND /OR THE TURF /LANDSCAPED AREAS.
4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA
UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP.
5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE
ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE
IT TO AN ADEQUATE IMP /BMP.
6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED
WITHOUT A PERMIT FROM THE CITY.
7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY
REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED.
8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM
WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN
IMPERVIOUS, NON -COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE
ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM
SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE
DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE
AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN
AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES
THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A
CITY- APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER
SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE
REQUIRED FOR THIS STRUCTURE.
SAN DIEGUITO WATER DISTRICT NOTES
1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE
STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC).
2. REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE
REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR
NON - EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS
PROJECT.
3. ALL EXISTING FACILITIES, WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSING, LINE
PARALLELING OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR
PROPOSED UTILITY CROSSING WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON
IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN
WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT.
4. CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND /OR ADJUST TO GRADE ANY
EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) WHICH IS
AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST MEET CURRENT WATER
AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. IF FACILITIES DO NOT MEET STANDARDS,
THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE OWNER'S EXPENSE.
"JIL �6 c . e����L \1�:�99:L�1[�1
6. MINIMUM HORIZONTAL SEPARATION OF 10 -FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN
DIEGO GAS AND ELECTRIC VAULTS.
7. ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS AND ALL OTHER TRAVELED
WAYS.
WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE SERVING.
8. CALIFORNIA STATE LAW ASSEMBLY BILL AB -1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN
THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECTIVE JANUARY 1, 2010. IN
COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS
PARTS.
STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES
CONCRETE WASHOUT
CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE
WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO
THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION.
CONSTRUCTION SITE ACCESS
A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS
SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL PANELSIPLATES.
CONSTRUCTION VEHICLES
A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND
ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE.
EROSION CONTROL
EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY
INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX.
NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER.
DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST
EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES.
REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY
REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION.
TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES.
EROSION SHALL BE PREVENTED BY PLANTING FAST - GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL.
PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE.
WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED.
ON-SITE CONSTRUCTION MATERIAL STORAGE
STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS
WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE
OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON-SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE,
AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS.
STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND
THE PERIMETER AT ALL TIMES.
TRAINING
CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS
STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY
OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES.
WASTE MANAGEMENT
CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR
WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED.
NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMSIDIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT
THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES.
DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN
CONTACT WITH ANY TRASH MATERIAL.
MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND
CLEARED VEGETATION CAN BE RECYCLED. NON- RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS
HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 7141195.
FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436-4151.
POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE.
PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY
CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES.
ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN
UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE
FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT,
CITY OF ENCINITAS AT (760) 633 -2770.
1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH
OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER:
THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT
THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO
ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK:
A. SEWERS - CSD - (760)-633 -2770
B. GAS & ELECTRIC - SDGE - (760)438-6200
C. WATER - SAN DIEGUITO WATER DISTRICT -1-800 -227 -2600
D. TELEPHONE - SBC BELL - (760)489.3411
E. CABLE TV - COX COMMUNICATIONS - (760)-806 -9809 X -2233
2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE:
(760)-633 -2770.
3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760 )633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT
OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL.
SHEET INDEX
SHEET DESCRIPTION
1 TITLE SHEET
2 GRADING PLAN & LEGEND
3 EROSION CONTROL PLAN
OWNER/APPLICANT \
RICHARD HULETT TURNER AND
GRACE EVELYN TURNER
TRUSTEES OF THE TURNER
FAMILY TRUST
1219 CRESTVIEW DRIVE
CARDIFF, CA 92007
PHONE: (619) 890 -0034
SITE ADDRESS
1219 CRESTVIEW DRIVE
CARDIFF, CA 92007
APN: 260 - 430 -84 -00
LEGAL DESCRIPTION
LOT 5 OF THE CITY OF ENCINITAS TRACT NO. 01-090, IN THE CITY
OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA,
ACCORDING TO MAP THEREOF NO. 11M FILED IN THE OFFICE
OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, 2125104.
N
S
J
a
ST
0
W
U
OWNER'S CERTIFICATE
W
BY CERTIFY THAT A REGISTERED SOILS ENGINEER OR 5
GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL
¢
GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY
r o
OF THE SITE.
Jt�
SEA`A�
I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S
OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND
0
PV�yo
AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS,
LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF,
ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY
VICINITY MAP
WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS,
EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR
N.T.S.
REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN
THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR
APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS.
SIGNATURE: I/ /G /v� DATE:
RICHARD TURNER
SOILS ENGINEER'S CERTIFICATE
1, J NNY A REGISTE D CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF
APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE
WAS MADE BY ME OR UNDER MY DIRECTION ON 11 -09-17 AND FOR AN UPDATE ON . ONE COMPLETE COPY OF THE SOILS
REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER.
FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS
REPORT FOR THIS PROJECT HAVE BEEN INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS.
SIGNED: L�
RCE NO.: 84406 �oQ�pFESS /Ory9`
EXP. DATE: 9/30119
JOB #: CTE JOB NO. 10- 14005G O No. 64408 2� z
*
EXP. 9 /30!(q
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD, SUITE 115 1qx clvk\-
ESCONDIDO, CA 92026 FOF CAO o
(760) 746 -4955
STATEMENT OF ENGINEER OF WORK
THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY
ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE
WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO
THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW
PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A
DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT
THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON.
THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES
FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE
ENGINEER AND HIS/HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND
ARISING OUT OF THE W-O_RK- PERFORMED BY THE ENGINEER.
SIGNATURE: DATE:
RONALD L. HOLL AY
RCE EXPIRES 3 -31 -19
810*
t
d
bbA,Inc. RONALD L. 'yp
land planning, civil englneedng, surveying HOLLOWAY r
5115 AVENIDA ENCINAS NO. 29271
SUITE "L"
CARLSBAD, CA. 92008 -4387
(760) 931 -8700 cry%
EARTHWORK DATA OF CALF
STEEPEST EXISTING NATURAL SLOPE ON -SITE = 26' H: 50% V (2:1)
MAXIMUM VERTICAL DEPTH OF CUT = 4.0'
MAXIMUM VERTICAL DEPTH OF FILL = 4.0'
CUT = 640 C.Y. FILL = 640 C.Y.
EXPORT = 0 C.Y. AREA OF LAND DISTURBANCE: 24,610 SOFT
REMEDIAL = 670 C.Y.
IMPERVIOUS AREA
IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 14,780 SQFT
ACTUAL PROPOSED IMPERVIOUS SURFACE: 1,600 SQFT
ALLOWABLE FUTURE IMPERVIOUS SURFACE (INCLUDING 15% CONTINGENCY): NA SQFT
PROJECT TOTAL IMPERVIOUS SURFACE: 16,380 SOFT
IMPERVIOUS AREA REPLACED: 0 SQFT
I BMP PROJECT STATUS
STANDARD
I PUBLIC WORKS I PLANNING AND BUILDING I PARKS AND RECREATION ISAN DIEGUITO WATER DISTRICT I ENCINITAS FIRE DEPARTMENT
9. ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED
WITH CATHODIC PROTECTION IN ACCORDANCE WITH WC -17 OR WC -18.
CONTRACTOR TO VERIFY EX/SANG �y !Y �i' f (- I� �•i %^'- f2 - /i� q rd 0�
UIIUTY LOCATONS do ELEVATION
PRIOR TO CONSTRUCTION SI DATE SI DATE SIGN DATE SIGN DATE S GN DATE
CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS DEVELOPMENT SERVICES DEPARTMENT DRAWING NO.
S u L L0 .31 C DESCRIPTION: ENC- 39.2" BRASS DISC. PLANS PREPARED UNDER SUPERVISION OF REC ME D: APPROVED: GRADING PLAN FOR:
LOCATION: NORTHWEST CORNER OF BIRMINGHAM HORIZONTAL: N/A %Z DATE: 9 ' �') 1219 CRESTVIEW DRIVE 13717 -G
DRIVE &LAKEDRNE �- I!) -21 -I'► '
RONALD L. HOLLOWAY DATE APN: 2GO- 43O -84 -00
RECORD FROM: SURVEY CONTROL NETWORK VERTICAL: N/A R.C.E. NO.: 29271 S NOWAK CHRISTOPHER L. MAGD KU
ELEVATION: 323.983 1 RONALD L. OLLOW EXP.: 331 -19 �ti•! g 9 ' y�ZOIR
DATUM: NAVD 88 REVIEWER INSPECTOR ENGINEER DATE DATE SHEET 1 OF 3
K: \Civil 3D \0774 \DWG \GP \0774- GP- Ol.dwg, 9/6/2018 9:12:36 AM
R
ro
I
�o
�a
y�
ro
W°f
h�
h�
e
9
2
r
r
8 �
a•
4
1
I\
x 278,9
0,
0
\ Conc,
APjy 260- 30-qD �\ x 2802
,
r
,
,
I
+ I p
---------
,
------------------ �'
- - - -- FF ;=77777 - �- _
ZQ !L CCU
EXISTING
BUILDING
n
�j
x
DO Conc,
�\ \\
n
//) x 309.1
z
r b%'
6 10
x 271,4
II
11
L:JBJ, ' If ' ' '
„
JL
0(i 60
,'� ,% LL'' ,
O Obsc�r &0 ` i i I`'I'I ',' //�, /,
7 / . / / , I
if I
R056' , A,
,SLOPES `,-
'ICAL SEE''
% ROSION
NTROL PLAN, \ \\
SYNTHETIC.
SYMBOL QUANTITY
PUT77NG GREEN
F
SEGMENfi�L oNRY,
WALL (KEYSTONNAAAOY'
TO 6 "X16 ")\\T, fA
T LESS THAN 3'},
PAD
EI
- ASPHALT CONCRETE /E _
INVERT ELEVAT7ON
x 31 , L�
COLLAR AROUND
PORTION �'
T> CONC, \
TW= 279.5
'
ITCH `�I' ArE
•'
�-
12" PIPE FOR�QNCRETE ,
'\
END OF PIPE -
APRO A OF
\ - - -
PIPE- E
- BEGIN VER77CAL CURVE MH -
MANHOLE
F GB'
2 .0\
\ FG�� �g.1
'
BW
- BOTTOM OF WALL NIS -
NOT TO SCALE
(E)
6
, ,
EASEMENT NOTES:
If
- CURB AND GUTTER PCC -
POINT OF COMPOUND CURVE
EXISTING FIRE HYDRANT
'C
WFIERf,
MASONRY PA VERI�S
EXIS77NG CONTOURS
�
- CATCH BASIN PE -
PAD ELEVARON
ri
EXIST. C.
BROW DITCH
II
11
L:JBJ, ' If ' ' '
„
JL
0(i 60
,'� ,% LL'' ,
O Obsc�r &0 ` i i I`'I'I ',' //�, /,
7 / . / / , I
if I
R056' , A,
,SLOPES `,-
'ICAL SEE''
% ROSION
NTROL PLAN, \ \\
BIO- RETENTION STRI
\
- SEE DETAIL ON
' - - - -2 ----------- - - - - -- - - -- -- ----- - - - - --
- - ---
--------------------------- - - ---
- - - - -- -- -
_
O u d, A ' 1
-- -
EXISTIN ,10,' PUBLIC- -
1, DRA(NA EASEMENT -LI
1 EDICATED -f'ER -
` 8067--__
C�
-------- -------- - -.
/Z
0
SYNTHETIC.
SYMBOL QUANTITY
PUT77NG GREEN
F
SEGMENfi�L oNRY,
WALL (KEYSTONNAAAOY'
TO 6 "X16 ")\\T, fA
T LESS THAN 3'},
PAD
EI
- ASPHALT CONCRETE /E _
INVERT ELEVAT7ON
x 31 , L�
COLLAR AROUND
PORTION �'
T> CONC, \
TW= 279.5
'
ITCH `�I' ArE
•'
�-
12" PIPE FOR�QNCRETE ,
'\
END OF PIPE -
APRO A OF
\ - - -
PIPE- E
- BEGIN VER77CAL CURVE MH -
MANHOLE
F GB'
2 .0\
\ FG�� �g.1
'
BW
- BOTTOM OF WALL NIS -
NOT TO SCALE
(E)
6
, ,
EASEMENT NOTES:
C &G
- CURB AND GUTTER PCC -
POINT OF COMPOUND CURVE
EXISTING FIRE HYDRANT
'C
WFIERf,
MASONRY PA VERI�S
EXIS77NG CONTOURS
�
- CATCH BASIN PE -
BIO- RETENTION STRI
\
- SEE DETAIL ON
' - - - -2 ----------- - - - - -- - - -- -- ----- - - - - --
- - ---
--------------------------- - - ---
- - - - -- -- -
_
O u d, A ' 1
-- -
EXISTIN ,10,' PUBLIC- -
1, DRA(NA EASEMENT -LI
1 EDICATED -f'ER -
` 8067--__
C�
-------- -------- - -.
/Z
0
, Conc. Ok
� x 314,1
If
,
'i ' i __
/ : X 311, 4 ' % / / / �— ��•..� ''' � , ; ,.� ' i,,R� — --- - - - --
_
----- --
;/
- -- --
d -- _ - _ ,
S 88'"45'41 144.39'' -
"
l/ - - -- ---
- - --
- use= _ ul
�] PH
283.0 r
if f 262-041-1
HYDRO SE�Ep NEW I ` `''�' Obscured Area
SLOPES ICAL �1 ' , � � „ ` � `, f '� - - - --
f EROSIO
s/
5:1�1� /
,
- - -- - - ----------- - "- ` - _l- %``�`-------------- -- --__ %
XIST C
CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT
A SfivW Lb - 31- DESCRIPTION: ENC - 39.2" BRASS DISC.
LOCATION: NORTHWEST CORNER OF BIRMINGHAM
DRIVE & LAKE DRIVE HORIZONTAL: 1" = 20'
RONALD L. HOLLOWAY
RECORD FROM: SURVEY CONTROL NETWORK VERTICAL: N/A
ELEVATION 323.983
DATUM: NAVD 86 1 REVIEWER IN PECTOR D0.@N
K: \Civil 3D \0774 \DWG \GP \0774- GP- 02.dwg, 9/6/2018 9:59:34 AM
PLANS PREPARED Utz
I0 -21 —Iq
DATE � I
) -3 -I ti RONALD L. HOLLO
i
T
,
/
A
i,
2 AAGt
LE
I it
JPERVISION OF
DATE: %-6"18
R.C.E. NO.: 29271
EXP.: 3 -31 -19
DESCRIPTION
DWG.NO.
SYMBOL QUANTITY
ABBREVIATIONS
SUBDIVISION BOUNDARY
6" CONCRETE
AC
- ASPHALT CONCRETE /E _
INVERT ELEVAT7ON
x 31 , L�
COLLAR AROUND
RIGHT -OF -WAY
BC
- BEGIN CURVE LT
LEFT
EXIS77NG WATER LINE
END OF PIPE -
BVC
- BEGIN VER77CAL CURVE MH -
MANHOLE
1307H ENDS
(GAS)
BW
- BOTTOM OF WALL NIS -
NOT TO SCALE
(E)
EXIS77NG TELEPHONE LINE
EASEMENT NOTES:
C &G
- CURB AND GUTTER PCC -
POINT OF COMPOUND CURVE
EXISTING FIRE HYDRANT
12" PVC PIPE
EXIS77NG CONTOURS
CB
- CATCH BASIN PE -
PAD ELEVARON
EXIST. C.
BROW DITCH
100
01 EXISTING BIOLOGICAL OPEN SPACE do STEEP
CDS
- CUL -DE -SAC PRC -
POINT OF REVERSE CURVE
EXISTING ELEVA IRON
SLOPE PRMVA71ON EASEMENT PER DOC.
CL
- -
CENTERLINE RCP
REINFORCED CONCRETE PIPE
PROPOSED ELEVA77ON
FG 35.5
NO. 2004 - 0148551, REC. 2125104.
CO
- CLEANOUT RT -
RIGHT
FILL SLOPE
CR
- CURB RETURN RW -
RIGHT -OF -WAY
` >lq LF
PROPOSED 12" PVC STORM DRAIN
= _ _ = 20 ><LF
® EXISTING SOUTHERN MLLOW SCRUB
DC
- DEPRESSED CURB SCO -
SANITARY SEWER CLEANOUT
DETAIL G
BIOLOGICAL OPEN SPACE EASEMENT PER DOC.
EC
- END CURVE SS -
SANITARY SEWER
- -�-
NO. 2004- 0148551, REC, 2125104.
EP
- EDGE OF PAVEMENT SG -
SUB GRADE
NOT TO SCALE
a
MASONRY BLOCK
EVC
- END VER77CAL CURVE SO -
STORM DRAIN
OT 4
31
(LEGACY STONE - 6716-)
FFC
- FRONT FACE OF CURB SDRSD -
SAN DIEGO AREA REGIONAL
14745
FF
- FINISHED FLOOR
STANDARD DRAWING
NOT TO SCALE
r]Pj��
FL
- FLOWLINE SW -
SIDEWALK
2 5 2 -04 l -J 9
FG
- FINISHED GRADE TB
TOP OF BERM
TOP OF
430-83
GB
- GRADE BREAK TC
CURB
x 313.9
HP
- HIGH POINT IF
W
'
— —
-
TOP OF WALL
ALL
�
f
t'
LEGEND
, Conc. Ok
� x 314,1
If
,
'i ' i __
/ : X 311, 4 ' % / / / �— ��•..� ''' � , ; ,.� ' i,,R� — --- - - - --
_
----- --
;/
- -- --
d -- _ - _ ,
S 88'"45'41 144.39'' -
"
l/ - - -- ---
- - --
- use= _ ul
�] PH
283.0 r
if f 262-041-1
HYDRO SE�Ep NEW I ` `''�' Obscured Area
SLOPES ICAL �1 ' , � � „ ` � `, f '� - - - --
f EROSIO
s/
5:1�1� /
,
- - -- - - ----------- - "- ` - _l- %``�`-------------- -- --__ %
XIST C
CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT
A SfivW Lb - 31- DESCRIPTION: ENC - 39.2" BRASS DISC.
LOCATION: NORTHWEST CORNER OF BIRMINGHAM
DRIVE & LAKE DRIVE HORIZONTAL: 1" = 20'
RONALD L. HOLLOWAY
RECORD FROM: SURVEY CONTROL NETWORK VERTICAL: N/A
ELEVATION 323.983
DATUM: NAVD 86 1 REVIEWER IN PECTOR D0.@N
K: \Civil 3D \0774 \DWG \GP \0774- GP- 02.dwg, 9/6/2018 9:59:34 AM
PLANS PREPARED Utz
I0 -21 —Iq
DATE � I
) -3 -I ti RONALD L. HOLLO
i
T
,
/
A
i,
2 AAGt
LE
I it
JPERVISION OF
DATE: %-6"18
R.C.E. NO.: 29271
EXP.: 3 -31 -19
DESCRIPTION
DWG.NO.
SYMBOL QUANTITY
SUBDIVISION BOUNDARY
-�
v
PROPERTY LINE
V
RIGHT -OF -WAY
EXIS77NG WATER LINE
(VV)
EXIS77NG SEWER LINE
( S )
EXIS77NG GAS LINE
(GAS)
EXIS77NG ELECTRICAL LINE
(E)
EXIS77NG TELEPHONE LINE
(T)
EXISTING FIRE HYDRANT
C01
EXIS77NG CONTOURS
100
FINISHED GROUND CONTOURS
100
CUT /FILL LINE
EXISTING ELEVA IRON
(FS 35.5)
PROPOSED ELEVA77ON
FG 35.5
PROPOSED SLOPES (2:1 MAX)
CUT SLOPE
FILL SLOPE
Q PCC aWX DITCH (TYPE B)
__DA '
` >lq LF
PROPOSED 12" PVC STORM DRAIN
= _ _ = 20 ><LF
ROPOSED GARDEN WALL (LE S THAN 3' HIGH)
EXISTING EASEMENT
LIMITS OF WORK
- -�-
10% MAX
10% MAX 6"
a
MASONRY BLOCK
a e.a
(LEGACY STONE - 6716-)
e'
DETAIL A
NOT TO SCALE
0.50' 1.67 &Do, 1.67'
OPEN SPACE
EASEMENT
BASKETBALL COURT
°. ii =S 1 $LCPE 5;1 SLOPE
3" OF MULCIVI EG TATION
8 OF BIO- RETENI►ON
_ -- _ - - -- -- -- - -- SOIL MEDIA
°o
Go
h
20 10 0' 20 40 60
a
l SCALE: 1" = 20' R
CONTRACTOR TO VERIFY EXISTING
UTILITY LOCA77ONS & ELEVATION ?�
PRIOR TO CONSTRUCTIONFBSSlo�
RONALD L I CRS
ROLLAWAY h
APjv / /��v ei�A Inc. N0. 29271 h�
/ e
land , dvfl
q/ J J plannt� englneertrlg, surveyft
5115 AVENIDA ENCINAS
SUITE °L° e of cstt �
CARLSBAD, CA. 92008 -4387
ENGINEERING DIVISION APPROVALS
RECO EN APPROVED:
S OW K CHRISTOPHER L.-MAGIOSKU
9-Z y -Zdk
DATE DATE
(760) 931 - -87700
'W4�44 9106118
RONALD L. HOLLOWAY ItE 29271 EXP. 3 -31 -19 DA 7E
CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO.
WING PLAN FOR:
1219 CRESTVIEW DRIVE 13717 -G
APN: 260- 430 -84 -00
SHEET 2 OF 3
1 1 1
CL_ cl- ` ,, i ` lLI
cl-
BMP STENCIL PLACEMENT NOTES
A) ALL STORM DRAIN INLETS AND CATCH BASINS WITHIN THE PROJECT AREA SHALL HAVE A STENCIL
OR 71LE PLACED WITH PROHIBITIVE LANGUAGE (SUCH AS:
"NO DUMPING' I LIVE IN <4VAME RECEIVED WATER>>") AND /OR GRAPHICAL ICONS
TO DISCOURAGE ILLEGAL DUMPING.
B) SIGNS AND PROHIBITIVE LANGUAGE AND /OR GRAPHICAL ICONS, WHICH PROHIBIT ILLEGAL DUMPING,
MUST BE POSTED AT PUBLIC ACCESS POINTS ALONG CHANNELS AND CREEKS WITHIN 7HE PROJECT
AREA.
C) LEGIBILITY OF STENCILS, 71LES AND SIGNS MUST BE MAINTAINED AND 71LES MUST BE PLACED
FLUSH WITH 774E TOP OF CONCRETE TO REDUCE TRIPPING BY PEDESTRIANS
CONSTRUCTION LEGEND
BEST MANAGEMENT PROTECTION & EROSION CONTROL
DESCRIPTI
QUANTIT Y
SYMBOL
SE -1 -SILT FENCE
630 L.F.
SE -5 -FIBER ROLL
130 L.F.
FR
SE -8- GRAVEL BAG BARRIER
60 EA.
WM1- MATERIAL DELIVERY STORAGE
1 EA.
M
WM5 -SOLID WASTE MANAGEMENT
1 EA.
M48-CONCRETE WASTE MANAGEMENT
1 EA.
W9- SANITARY /SEP71C WASTE MANAGEMENT
1 EA.
a
T01- STABILIZED CONSTRUCTION ENTRANCE
360 S.F.
EC -4 HYDROSEEDING/ BONDED FIBER MATRIX
5745 S.F.
LLLLL
EC -7 GE07EX77LE MATS
EC -10 VELOCITY DISSIPATION DEVICES
30' 15'
SCALE: 1" = 30'
60' 90'
EXTRA STRENGTH FILTER FABRIC
NEEDED WITHOUT WIRE MESH Sl
STEEL OR _\ 11
WOOD POSWT
p 1 11/,
p jp11/
UPSTREAM SECURELY TO 1v•/ O/1p1NlI / n1'11;/1g/1 / 1n%I;O/ i ;II; IO
i
j11/10'
SIDE OF POST 11111 III %IIIIIIIIjll jIPIIOIIII�IIIIj�Ajll �j101jIIlO�IIIIIIIIIIIiIVlllll
IOIIIAlI0j01111II�1111j1111jII1111F11ly!0jl��llllll �
II/�llll 1111111 ,j11111111111111�IIIIII�i II
II ,1111,1 /11111111111111�IIIIIII
1101 jI1101jIIIIIIIIII �Y
j��II�II�IIII
SILT FENCE
NO SCALE
I
R FABRIC
3.
MINICOARSE
MUm 1
TH Dr 12'
STABILIZED
CONSTRUCTIONEN7RANCE
NO SCALE
GRAVEL BAGS OVERLAP
nurn norm
GAP BETWEEN BAGS THREE LAYERS OF GRAVEL BAGS
ACTS AS SPILLWAY WITH ENDS OVERLAPPED
GRAVEL BAGS
NO SCALE
2 BAGS HIGH (TYPICAL)
1.0' MINIMUM
(TYPICAL)
QX 1
v
TIN
GRADED SURFACE
GRAVEL BAG DETAIL fug
NO SCALE
fast
Wrn
RONAW L
m HOLLOWAY n�
bhA, Inc. NO.2921 g
ning, cMI engheeft, swvwft *`p
5115 AVENIDA ENCINAS 1d �iVn'
SUITE "L" OF CASK
CARLSBAD, CA. 92008 -4387 °
(760) 931 -8700 Q�
,�r�x.a-W 9106118
RONALD L. HOLLOWAY V RCE 29271 EXP. 3 -31 -19 DA 7E
CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT "tom "' "t" °': """ " "" tr: ` "t""t" tr: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO.
ft, Ca U LIT 3 (A-3l•ch DESCRIPTION: ENC- 39.2 °sRassDlsc. PLANS PREPARED UNDER SUPERVISION OF RECOMME ED: APPROVED: GRADING PLAN FOR:
LOCATION: NORTHWEST CORNER OF BIRMINGHAM DATE: 9'fo-)? 1219 CRESTVIEW DRIVE
DRIVE & LAKE DRIVE HORIZONTAL: 1" = 20' N IA
RONALD L. HOLLOWAY DATE APN: 260- O -H4 -OO 13717 -G
RECORD FROM: SURVEY CONTROL NETWORK VERTICAL: N/A R.C.E. NO.: 29271 NOWAK CHRISTOPHER L. MAG SKU
ELEVATION: 323.983 -31'l i RONALD .1 OLLOWA °� N -(� 9 ZO—Z%1 g
DATUM: NAVD88 PP%/IF%NFa iuc F(`Tna rA _ FinaimFFa EXP.: 3 -31 -19 �q�°� DATE SHEET 3 OF 3