Loading...
1998-5744 GC I T Y OF E N C I N I T A S E1 'VEERING SERVICES DEPARTMF 505 S. VULCAN AVE. ENCINITAS, CA 92024 GRADING PERMIT PARCEL NO. : 264- 240 -3800 JOB SITE ADDRESS: TRES VISTAS ESTATES APPLICANT NAME XION INVESTMENTS INC. MAILING ADDRESS: 131 ESCONDIDO BLVD. SOUTH CITY: ESCONDIDO STATE: CA ZIP CONTRACTOR : TOM YODER GRADING LICENSE NO.: 277938 ENGINEER : PASCO ENGINEERING INC. PERMIT ISSUE DATE: 12/10/98 PERMIT EXP. DATE: 12/10/99 PERMIT ISSUED BY INSPECTOR: TODD BAUMBACH ------- ------------ - - - - -- PERMIT FEES & DEPOSITS 1. PLAN CHECK FEE 2. INSPECTION FEE 3. PLAN CHECK DEPOSIT: PERMIT NO.: 5452GI PLAN NO.: 5452 -G PHONE NO.: 760 - 738 -7500 92025- PHONE NO.: 760 -741 -3310 LICENSE TYPE: C -12 UEN0.' F 9- 259 -c212 2,900.00 4. INSPECTION DEPOSIT: .00 8,564.00 5. SECURITY DEPOSIT 218,808.80 .00 6. Flood Control Fee: 8,613.00 DESCRIPTION OF WORK ------------------------- - - - - -- EARTHWORK /PRIVATE ROAD & DRAINAGE IMPROVEMENTS /LOT ACCESS DRIVEWAYS/ EROSION CONTROL FOR "TRES VISTAS ESTATES ", TRACT 97 -201 (TPM). A MINOR SUBDIVISION OF 4EA SFD LOT, 1EA REM PCL. EARTHWORK: 16,900CY CUT /FILL. DRAIN: 570LF PIPE /11EA HEADWALL /4EA CATCH BASIN /240LF DOWNDRAIN /3,140LF DITCH /220CY CHANNEL /11CY RIP -RAP. SURFACE: 41,012SF AC PAVING /BERM. Letter dated Sep 17 1998 applies. Sanitary sewer per separate permit. - - -- INSPECTION ---------- - - - - -- DATE -- - - - - -- INSPECTOF.'S SIGNATURE INITIAL INSPECTION COMPACTION REPORT RECEIVED ENGINEER CERT. RECEIVED ROUGH GRADING INSPECTION FINAL INSPECTION I HEREBY ACKNOWLEDGE THAT I HAVE READ THE APPLICATION AND STATE THAT THE INFORMATION IS CORRECT AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING EXCAVATING AND GRADING. AND THE PROVISIONS AND CONDITIONS OF ANY PERMIT ISSUED PURSUANT TO THIS APPLICATION. SIGNATURE Xr0A)1NdE�Ti- lti ✓i5 �Ne AZ(244� A - ,�� /��i PRINT NAME CIRCLE ONE: K. OWNER 1 2. AGENT 3. 0TH -Dec_ /1) , DATE SIGNED (%6 73�= 7�_, r TELEPHONE NUMBER C' T Y O F E N C I N I T NEERING SERVICES DEPARTN 505 S. VULCAN AVE. ENCINITAS, CA 92024 CARDIFF SANITATION DISTRICT SEWER CONSTRUCTION PERMIT PERMIT NO.: DCS272 vsavv= ssass= sv=s a=s saav== vva= v=av asvvaasaaav= asas =s =a =v = =es =as = =saasa =saasa =ae= PARCEL NO. : 264- 240 -3800 PLAN NO.: CS -272 JOB SITE ADDRESS: TRES VISTAS ESTATES APPLICANT NAME XION INVESTMENTS INC. MAILING ADDRESS: 375 RHO SANTA FE RD S #103 PHONE NO.: 760-738 -7500 CITY: SAN MARCOS STATE: CA ZIP: 92069- CONTRACTOR : BURTECH PIPELINE PHONE NO.: 760 - 634 -2415 LICENSE NO.: 692890 LICENSE TYPE: A INSURANCE COMPANY NAME: ACCEPTANCE INSURANCE COMPANY POLICY NO. : C98CGI236 POLICY EXP. DATE: 11/01/99 ENGINEER : PASCO ENGINEERING INC. Azl%� 212 P ERMIT ISSUE DATE: 6/02/99 PERMIT EXP. DATE: 11/01/99 PERMIT ISSUED BY: INSPECTOR: TODD BAUMBACH ------------------- - - - - -- PERMIT FEES & DEPOSITS ---------------------------- 1. PERMIT FEE .00 4. INSPECTION DEPOSIT: 850.00 2. INSPECTION FEE .00 5. SECURITY DEPOSIT 28,837.00 3. PLAN CHECK DEPOSIT: 850.00 ------------------- - - - - -- DESCRIPTION OF WORK --- -- --- --- ---- ---------- - - - - -- PUBLIC SEWER IMPROVEMENTS TO INCLUDE 425LF MAIN, 20LF ENCASEMENT, SEA LATERAL, 4EA MANHOLE, ALL FOR TRACT 97 -201, MINOR SUBDIVISION OF 4 SFD PCLS & I REM PCL. LETTER DATED SEP 17 1998 APPLIES. AS- BUILTS & 1YR WARRANTY PERIOD REQUIRED. WASTEWATER DISCHARGE PERMIT(S) DEFERRED. CONNECTS TO EXIST MAIN CS -146. - - -- INSPECTION ------- --- - - - - -- DATE -- - - - - -- INSPECTOR'S SIGNATURE - - -- INITIAL INSPECTION FINAL INSPECTION I HAVE CAREFULLY EXAMINED THE COMPLETED PERMIT AND DO HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT ALL THE INFORMATION IS TRUE. k -y -lf DATE SIGN D PRINT NAME TELEPHONE NUMBER CIRCLE ONE: 1. OWNER 2. AGENT 3. OTHER cgyp ACfja� C.T T Y O F E N C I N I T A S I NEERING SERVICES DEPARTM' 505 S. VULCAN AVE. ENCINITAS, CA 92024 GRADING PERMIT PERMIT NO.: 5744G1 ....................................................... m........ a............ PARCEL NO. : 264- 240 -3800 PLAN NO.: 5744 -G JOB SITE ADDRESS: REM PCL TRES VISTAS ESTATES APPLICANT NAME XION INVESTMENTS INC. MAILING ADDRESS: 375 RANCHO SANTA FE RD. #103 PHONE NO.: 760- 738 -7500 CITY: SAN MARCOS STATE: CA ZIP: 92069 - CONTRACTOR : TOM YODER GRADING PHONE NO.: 760 - 741 -3310 LICENSE NO.: 277938 LICENSE TYPE: C -12 ENGINEER : PASCO ENGINEERING INC. P 0 E NO.: 619- 259 -8212 PERMIT ISSUE DATE: 4/06/99 PERMIT EXP. DATE: 4/06/00 PERMIT ISSUED BY: INSPECTOR: TODD BAUMBACH ------------------- - - - - -- PERMIT FEES & DEPOSITS ---------------------- - - - - -- 1. PLAN CHECK FEE 700.00 4. INSPECTION DEPOSIT: .00 2. INSPECTION FEE 282.00 5. SECURITY DEPOSIT 5,636.00 3. PLAN CHECK DEPOSIT: .00 ------------------- - - - - -- DESCRIPTION OF WORK ------------------------------- EARTHWORK /DRAINAGE IMPROVEMENTS /EROSION CONTROL TO ENABLE CONSTRUCTION OF SINGLE FAMILY DWELLING ON REMAINDER PARCEL WITHIN TRACT 97 -201, MINOR SUBDIVISION. EARTHWORK: 900CY CUT /FILL. DRAIN: IEA AREA /IEA UNDER /15LF PIPE. LETTER DATED FEB 26 1999 APPLIES. CERTIFICATE OF COMPLIANCE ALLOWS BUILDABLE SITE. EXIST PMT 5452GI SUPERSEDED IN PART. SEWER PER DCS272. - - -- INSPECTION ---------- - - - - -- DATE - - - - - - -- INITIAL INSPECTION COMPACTION REPORT RECEIVED ENGINEER CERT. RECEIVED ROUGH GRADING INSPECTION FINAL INSPECTION INSPECTOR'S SIGNATURE - - -- I HEREBY ACKNOWLEDGE THAT I HAVE READ THE APPLICATION AND STATE THAT THE INFORMATION IS CORRECT AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING EXCAVATING AND GRADING, AND THE PROVISIONS AND CONDITIONS OF ANY PERMIT ISSUED PURSUANT TO THIS APPLICATION. i SI NATURE DATE.,SIGNIfb P17iff �i i //� iL/tl TELEPHONE NUMBER CIRCLE ONE: 1. OWNER 2.1AGENT 3. OTHE 3C4003M September 22, 1998 Jeff Garami Engineering Department City of Encinitas 505 South Vulcan Avenue Encinitas, CA 92024 Dear Mr. Garami: 1 M'%rOWt111811tsq 111C. Thank you for your prompt response with regards to your letter dated September 17, 1998. With respect to posting of Surety deposits fo 218,807 for Gradrgan�d $28,837 for Sewer, will it be acceptable to the City ' a "Set Aside Letter" is-provided from Scripps Bank, stating that the Bank has set asi ° ount of this security for this purpose in lieu of posting a Surety Bond? I will be grateful if you can let us know this at your earliest convenience. Sincerely, X1ON Investments, Inc. Zach A. Abbasi ZA/pg cc: Hans Jensen Wayne Pasco 131 south ex dldo boulevard escoudldo, caflf mla 92025 760/738-7555 760/734-7510 fax / ENGINEERING SERVICES DEPARTMEN. APPLICATION NO. ENGINEERING DEVELOPMENT APPLICATION - OB SRE DDRESS L- O LC AN G A4 I� THE ADDRESS S � I ��S CITY, STATE, ZIP CODE r� ^�� �3�,�tga Vf�r'7 R'T— Y�c�rti+V -- TELEPHONE NO. I'oio �(N /may /zM S ol c- CIVIL ENGINEER INFORMAT16/V�/� /�r 1/ 6 10 p4-ls c0 NG NAME 535 .N Alwr /01 "A " ADDRESS SOLANA aL_ACA -1 922075 CITY, STATE, ZIP TELEPHONE NO. RCE e9577 Z5`�-62lZ REGISTRATION NO SIGNATU JOE YuHRS PRINT NAME ASSESSOR PARCEL NO. iiL 2Gd 2 40 - 30 —� -2�i'J 3�' CONTRACTO INFORMATION NAME ADDRESS CITY, STATE, ZIP CODE TELEPHONE NO. STATE LICENSE NO. & TYPE SOILS ENGINEER INFORMATION VINJE 6 y1IDnLETOA/ NAME 24Jr0 VINEWVCD A4 +t 1oZ ADDRESS ESCoA1t;rInC5, CA 9 Z OZ4 7Ga - 743 -1Z!¢ CITY, STATE, ZIP TELEPHONE NO. REGISTRATION NO DESCRIPDON OF WORK TO BE DONE lk'l 61- CASE NO.: - 1i DATE SIGNED (,/9 -259 -8Z/ Z TELEPHONE NO. F f'r-1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (FOR OFFICE USE ONLY) c TYPE OF APPLICATION DATE COMPLETED DEPOSITS AND [ ] FEES PT AGREEMENT, COV., DOC. PERMIT /APPLICA FE Q) PAID [ J BEACH ENCROACHMENT PLAN CHECK FE [ J CO STRUCTION J_J_ ADDITIONAL PLAN CH CK _ [ J AL MAP 1q�QrCp3q(�'(•p' J FLOOD CONTROL FEE: [( NAL PARCEL MAPR I fi � sA IJ2i� INSPECTION FEE /DEPOSIT: GRADING �_/_ SECURITY DEPOSIT: —_ [ ] IMPROVEMENT /�_ (CIRCLE ONE OF EACH) ENT / PERMIT: NEWSRACK — ASSIGN /BOND ASSIGN /BOND [ ] P MANENT ENCROACHMENT _f�_ CASH /CD /LOC CASH /CD /LOC SFRilf�iAN- � —j _ MONUMENTATIONDEPOSIT: [ J STREET NAME CHANGE _/�_ RETURN EXCESS DEPOSITS TO: ( J STREET VACATION J /_ ] I OWNER DATE: _ /_f_ [ J TEMPORARY ENCROACHMENT JJ_ [ [ CONTRACTOR AMOUNT: b [ UTILITY CONSTRUCTION ��_ (J ENGINEER COMMENTS: [ I OTHER ENG( kERING DEVELOPMENT CHECKLIST GENERIC CHECKLIST SUBMITTAL REQUIREMENTS MAP RECORDED ; RELATED PERMIT AS MBEERR c .PLAN APPROVED ( %/) `K COST ESTIMATE APPROVED & ATTACHED 4 BLUELINES RECEIVED CIVIL ENGINEER REGISTRATION NO. JADDITIONAL NTRACTOR LICENSE NO. URITY DEPOSIT POSTE INITIAL REVIEW DEPO51 / EE P ID REVIEW D SIT /FEE PAID G' S PECTION DEPOSIT /FEE POSTED SEWER CONSTRUCTION CHECKLIST FIED ON APPLICATIONS MAP nl!V QN REFERENCE MAP ACEL ANNEXED TO E.S.0 E WER BOOK CHECKED FOR )POGRAPHY EVALUATE SEMENT OR RIG -WA TERAL O IN ' 1 EWER MAIN NO. 4TER DISCHARGE PERMIT G PERMIT rONTRACTOR LICENSE TYPE -A /C34 STANDARD CONDITIONS SIGNED � J CONSTRUCTION /IMPROVEMENT PERMITr=FdT ASBUILTS REQUIRED WARR 49Y RETENTION APPLIES IMPROVEMENT CHECKLIST _ PROJECT IDENTIFIED ON APPLICATIONS MAP STANDARD CONDITIONS SIGNED PROJECT IDENTIFIED ON REFERENCE MAP TRAFFIC CONTROL PLAN ACCEPTED _ IDENTIFY IMPROVEMENT TYPE AS-BUILTS REQUIRED (I.E.: ROAD /DRAIN /PARK/TRAIL) WARRANTY RETENTION APPLIES CONTRACTOR LICENSE TYPE: A GRADING CHECKLIST PROJECT IDENTIFIED ON APPLICATIONS MAP PROJECT IDENTIFIED ON REFERENCE MAP I ST PLANNING SUBMITTAL SIGN MYLAR O`PLA NCB MAP CHECKLIST ROJECT IDENTIFIED ON APPLICATIONS MAP ROJECT IDENTIFIED ON REFERENCE MAP CHIEF CRITERIA FOR PERMITIp� SOIL ENGINEER REGISTRATION NO. CONTRACTOR LICENSE TYPE HAUL ROUTE DESIGNATED FLOOD CONTROL FEES: PRIVATE ROAD �rs 119—LAND SURVEYOR REGISTRATION NO. MONUMENTATION DEFERRED? CONSTRUCTION CHECKLIST _ STANDARD WORK ONLY TRAFFIC CONTROL PLAN ,ACCEPTED CONTRACTOR LICENSE TYPE A /C8 /C12 PERMIT FEE STANDARD CONDITIONS SIGNED PERMANENT ENCROACHMENT CHECKLIST _ NON - STANDARD WORKS STANDARD CONDITIONS SIGNED FIELD ENGINEER APPROVAL TRAFFIC CONTROL PLAN ACCEPTED MAINTENANCE AND REMOVAL COVENANT PERMIT FEE •— xis"' -,, City of Encinitas February 26, 1999 ENGINEERING SERVICES DEPARTMENT Xion Investments Inc. 131 South Escondido Boulevard Escondido, CA 92025 Re: Tract 97 -201 (TPM) "rem pcl Tres Vistas Estates" Grading Application 5744GR (Cl Tres Vistas /SFD) A.P.N. 264-240-38 Permit issuance requirements Capital Improvement Projects District Support Services Field Operations Subdivision Engineering Traffic Engineering This letter shall serve to briefly summarize the Grading Permit process. Drawing 5744 -G has been approved by the Director of Engineering Services, effective February 25, 1999, and shall remain valid for three years. In order to obtain a Grading Permit to construct per this Drawing, you will need to satisfy the following requirements: (1) Post a Security Deposit in the amount of $5,636 -00 to guarantee performance of earthwork, drainage improvements, and erosion control. Up to eighty percent of the amount may be in the form of a Performance Bond issued by a State of California licensed surety company. Twenty percent has to be in the form of cash, a certificate of deposit, a letter of credit, or an assignment of account. The City must pre- approve any financial instrument's format. Complete the Security Obligation Agreement. (2) Pay a non - refundable Inspection Fee of $282.00. (3) Provide 4 blueline prints of the approved Drawing. (4) Provide the name, address, telephone number, and state license number of your construction contractor, if not yourself. (5) Sign the Permit. Any authorized representative of the property owner may sign. The Permit will expire in 1 year. Once the Grading Permit is issued, advance notice of 48 hours must be given prior to you or your contractor scheduling the mandatory pre - construction conference. See Grading Note 49. Construction changes, prepared by the Engineer of Work, should be submitted to the Engineering Services Department as redlined mark -ups on 2 blueline prints of the approved Drawing. Changes are subject to approval prior to field implementation. JSG /gr5744.docl TEL 760 -633 -2600 / FAX 760 -633 -2627 505 S. Vulcan Avenue. Encinitas. California 920243633 TDD 760-633 -2700 �* recycled paper Prior to issuance of a Building Permit, a rough grading approval will be needed from the assigned Engineering Inspector. Typically, rough grading is defined as certified pad preparation and soil compaction, substantial completion of improvements, and safe access. A reduction of up to 75% of the posted Security Deposit may be forthcoming and merited. As- builts, prepared by the Engineer of Work and approved by the Engineering Services Department, may be required prior to Final Inspection. A Final Grading Report may be acceptable in -lieu of as- builts at the discretion of the assigned Engineering Inspector. Satisfactory completion of Final Inspection is a prerequisite to release of the remainder of the posted Security Deposit. Please note that the Building Final Inspection is a separate event and may not necessarily coincide with Grading Final Inspection. The property owner and contractor will be responsible for the restoration of property corner monumentation moved or destroyed by the grading activity. A licensed land surveyor or qualified civil engineer will be needed to do the work, subsequently filing a Comer Record with the County. See Grading Note k6. This letter is limited in scope. During the Building Permit process you will need services and be subject to regulation from as follows: the Current Planning Division, Building Inspection Division, Fire Prevention Bureau, and Cardiff Sanitation District, all of the City, and the Olivenhain Municipal Water District, Encinitas Union School District, and San Dieguito Union High School District, all separate public agencies. Please inquire at their respective counters. Additional engineering requirements will be forthcoming during the Building Permit process, including, but not necessarily limited to, coordination of the building site plan with the grading plan, resolution of any outstanding public improvement issues, and assessment and collection of traffic mitigation, sanitary sewer, and flood control fees. Should you have any questions, please contact me at (760) 633 -2780, or you may wish to visit the Engineering Counter at the Civic Center. Sincerely, q4f,,- Jeffrey S. Garami Engineering Technician Subdivision Engineering cc Pasco Engineering, Engineer of Work Greg Shields, Senior Civil Engineer Todd Baumbach, Engineering Inspector Greg Caudill, Engineering Technician enc 1SG /gr5744.doc2 ENGINEERING SERVICES DEPARTMENT city Of Capital Improvement Projects District Support Services Encinitas Field Operations Subdivision Engineering Traffic Engineering September 17, 1998 arm: Zahc or Abbasi Xion Investments Inc. 131 South Escondido Boulevard Escondido, CA 92025 Re: Tentagye Parcel Map 97 -20I If Tres V i stas Estates" (Minor subdivision of 4 SFD, I REM parcels) Grading Application 5452GR [Pad Grading & Erosion Control, Private Road] Sewer Construction DCS272 [Public Sewer] A.P.N. 264-240-38 Permit issuance requirements This correspondence shall serve to briefly summarize the Engineering Permit process. Drawing 5452 -G and Drawing CS -272 have been approved by the Senior Civil Engineer, Subdivision Engineering, effective September 15, 1998, and will remain valid for three years. In order to obtain the necessary Engineering Permits to construct per these Drawings, you will need to satisfy the following requirements: (1) Post Security Deposits as follows: (a)GRADING PERMIT... in the amount of $218,809.00 to guarantee performance of earthwork, private road and drainage improvements, access driveways, and erosion control, and (b SEWER CONSTRUCTION PERMIT... in the amount of $28,837.00 to guarantee performance of public sewer improvements. Up to 80% of the amount in 2(a) and 100% of the amount in 2(b) may be in the form of a Performance Bond issued by a State of California licensed surety company. Twenty percent of the amount in 2(a) has to be in the form of cash, a certificate of deposit, a letter of credit, or an assignment of account. The City must pre- approve any financial instrument's format. (2) Pay a non - refundable Inspection Fee and Inspection Deposit, the latter subject to cost recovery, respectively, as follows: (a)GRADING PERMIT... of $8,564.00, and (b)SEWER CONSTRUMON PERMIT... of $850.00. 1SG /97.201.docI TEL 760 - 633.2(410 / FAX 760 -633 -2627 505 S. Vulcan Avenue, Encinitas. California 92024.3633 l "DD 760 -633 -2700 1� recycled Paper 1116 . (3) Pay a Flood Control Fee of $8,613.00. The rate is $0.21 /SF and is assessed on the private road improvements and access driveways. Additional assessments will be levied during the development of the lots. (4) Provide the name, address, telephone number, and state license number of the construction contractor. Construction of public improvements is restricted to qualified contractors. In order to be allowed to construct the public sewer improvements, the contractor will need to possess either a valid Type "A" General Engineering or Type "C -34" Pipeline state license, and meet the minimum insurance requirements as stated on the accompanying handout. (5) Sign the Permits. Any authorized representative of the property owner may sign. Permits are valid for no more than one year and may expire earlier due to expirations on letters of credit and/or insurance policies. Once the Engineering Permits are issued, advance notice of 48 hours must be given prior to you or your contractor scheduling the mandatory pre - construction conference. For more detail, see Grading Note #9. Informal phasing of the project may necessitate more than one such conference. Pursuant to Fire Department rules and regulations, prior to any combustible materials being placed on -site, the private road shall have received its first lift of asphalt paving. Construction changes, prepared by the Engineer of Work, should be submitted to the Engineering Services Department as redlined mark -ups on 2 blueline prints of the approved Drawing. Changes are subject to approval prior to actual construction. Substantial increases in valuation due to the proposed changes may be cause for assessment and collection of additional inspection fees and security deposit. Prior to issuance of any Building Permit, a rough grading approval will be needed from the assigned Engineering Inspector. At a minimum, rough grading is defined as certified pad preparation and soil compaction, and safe access. A proportional reduction of up to 75% of the Security Deposit assigned to the Grading Permit may be merited and forthcoming. As- builts of Drawing 5452 -G and Drawing CS -272, prepared by the Engineer of Work and approved by the Engineering Services Department, will be required prior to Final Inspection and Acceptance Inspection. Satisfactory completion of Final Inspection is a prerequisite to full release of the Security Deposit assigned to the Grading Permit. Please note that Building Permit final inspections are a separate event apart from any Engineering Permit final inspection and are not necessarily coincidental. Satisfactory conclusion of Acceptance Inspection and formal acceptance by the Cardiff Sanitation District Board of Directors is a prerequisite to a 75% reduction in the Security Deposit guaranteeing performance of public sewer improvements and start of the mandatory one -year 1SG /97- 201.doc2 =s Warranty Period. The retention shall be held for the duration of the Warranty Period and will be released only after the satisfactory completion of the Warranty Inspection. The Warranty Inspection cannot be scheduled until after the expiration of the Warranty Period. This letter does not change subdivider obligations per the proposed Parcel Map. This letter is limited in scope. During the Building Permit process, you will need services and be subject to regulation from as follows: the Current Planning Division, Building Inspection Division, Fire Prevention Bureau, and Cardiff Sanitation District, all of the City, and the Olivenhain Municipal Water District, Encinitas Union School District, and San Dieguito Union High School District, all separate public agencies. Please inquire at their respective counters. Additional engineering requirements will be forthcoming during the Building Permit process, including, but not necessarily limited to, coordination of the building site plan with the grading plan, resolution of any outstanding public improvement issues, and assessment and collection of flood control, sanitary sewer, and traffic mitigation fees. If there should be a substantial delay in the start of your project, please request an update of this letter. Should you have any questions, please contact me at (760) 633 -2780, or you may wish to visit the Engineering Counter at the Civic Center. Sincerely, Jeffrey S. Garami Engineering Technician Subdivision Engineering cc W.A. Pasco Engineering, Engineer of Work Greg Shields, Senior Civil Engineer Todd Baumbach, Engineering Inspector Greg Caudill, Engineering Technician enc Requirewnfafor Proof of 1n ance JSG /97- 201.doc3 ENGINEERING SERVICES DEPARTMENT CityCityof Capital Improvement Projects or Support Services Encinitas Field Operations Subdivision Engineering Traffic Engineering ROUGH GRADING APPROVAL TO: Subdivision Engineering Public Service Counter FROM: Field Operations Private Contract Inspection RE: Grading Permit No. 5452 G r Name of Project TO-Es VIST-As E5'nWYeS Name of Developer E�o b A V 1 S Site Location TCPr-Lo,- 1' .1 (address ...number ...street name ...suffix) (IOU !bldg) I have inspected the grading at the subject site and have verified certification of the pad by the Engineer of work, Tou YuRAS dated _7 --,2-q and certification of soil compaction by the Soil Engineer, r a a ddfddk'fon, dated (o --21 -2600 1 am hereby satisfied that the rough grading has been completed in accordance with the approved plans and specifications, Chapter 23.24 of the Municipal Code, and any other applicable engineering standards and specific project requirements. Based on my observation and the certifications, I take no exception to the issuance of a building permit for the lot(s) as noted or Phase ,/�/t if any, but only in so far as grading is concerned. However, this release is not intende to certify the project with respect to other engineering concerns, including public road, drainage, water, sewer, park, and trail improvements, and their availability, any other public improvements, deferred monumentation, or final grading. Prior to final inspection of the Building Permit(s) and legal occupancy, I need to be further advised so that I can verify that final grading (i.e., finished precise grading, planting and irrigation) has been completed in accordance with the approved plans and specifications. 7 - -- ZS--- 2000 (Date) (Signature of Senior Civil Engineer, only if appropiate) (Date) Reference: Building Permit No. - -- Special Note: Submit this form, if completed, to counter staff merely by placing a copy of it in both engineering technicians' in- boxes. Please remember to do a final inspection of the grading permit and submit that paperwork, when completed. Office staff will handle the appropiate reductions in security, if any, and coordination with Building Inspection. Thank you. ]SG /field3.doc I TEL 760 -633 -2600 1 FAX 760 -633 -2627 505 S. Vulcan Avenue- Encinitas, California 92024 -3633 7'DD 760 -633 -2700 t!� recycled paper ENGINEERING SERVICES DEPARTMENT Capital Improvement Projects City Of J District Support Services Encinitas Field Operations Subdivision Engineering Traffic Engineering ROUGH GRADING APPROVAL TO: Subdivision Engineering Public Service Counter FROM: Field Operations Private Contract Inspection RE: Grading Permit No. 61+524T Name of Project TREs ✓57r4s ESTAT85 Name of Developer Site Location (address ...number RM.0 t D eV eLo PARCei- 2 name ...SUf lXJ ooU /bldg) I have inspected the grading at the subject site and have verified certification of the pad by the Engineer of Work, Sco Cwt ineWi dated 7 -10 - 00, and certification of soil compaction by the Soil Engineer, nett c 1 dated , 7 —10 — do, I am hereby satisfied that the rough grading nJ& been completed in accordance with•the approved plans and specifications, Chapter 23.24 of the Municipal Code, and any other applicable engineering standards and specific project requirements. . Based on my observation and the certifications, I take no exception to the Issuance of a building permit for the lot(s) as noted or Phase µiPr , if any, but only in so far as grading is concerned. However, this release is not intended to certify the project with respect to other engineering concerns, including public road, drainage, water, sewer, park, and trail improvements, and their availability, any other public improvements, deferred monumentation, or final grading. Prior to final inspection of the Building Permit(s) and legal occupancy, I need to be further advised so that I can verify that final grading (i.e., finished precise grading, planting and irrigation) has been completed in accordance with the approved plans and specifications. -7 f8 —oc7 (Date) (Signature of Senior Civil Engineer, only if appropiate) (Date) Reference: Building Permit No.�&- - _z_CAp Special Note: Submit this form, if completed, to counter staff merely by placing a copy of it in both engineering technicians' in- boxes. Please remember to do a final inspection of the grading permit and submit that paperwork when completed. Office staff will handle the appropiate reductions in security, if any, and coordination with Building Inspection. Thank you. JSG /field1doc I TEL 760 - 633 -2600 1 FAX 760 -633 -2627 505 S. Vulcan Avenue. Encinitas, California 92024 -3633 TDD 760 -633 -2700 recycled paper ENGINEERING SERVICES DEPARTMENT City p f Capital Improvement Projects District Support Services Encinitas Field Operations Subdivision Engineering Traffic Engineering ROUGH GRADING APPROVAL TO: Subdivision Engineering Public Service Counter FROM: Field Operations Private contract Inspection RE: Grading Permit No. 554 GT �t Name of Project (IISTf}S FS'/73'fEIS 0 � ts' Name of Developer R MC I ]fie e Io am ent ��� Site Location PARCEL 3 pIJLy � !address ...number ..s,.reet name ...suffix! llotJ (bldg! I halve inspected the grading at the subject site and have verified certification of the pad by the Engineer of Work, �II5c9 ��61a�lated 5• • oo and certification of soil compaction by the Soi Engil neer, , dated e S •- 2b —oo. I am hereby satisfied that the rough grading a been completed in accordance with:2he approved plans and specifications, Chapter 23.24 of the Municipal Code, and any other applicable engineering standards and specific project requirements. . Based on my observation and the certifications, I take no exception to the issuance of a building permit for the lot(s) as noted or Phase — , If any, but only in so far as grading is concerned. However, this release is not intended to certify the project with respect to other engineering concerns, Including public road, drainage, water, sewer, park, and trail improvements, and their availability, any other public Improvements, deferred monumentation, or final gracling. Prior to final inspection of the Building Permit(s) and legal occupancy, I need to be further advised so that I can verify that final grading (i.e., finished precise grading, planting and irrigation) has been completed In accordance with the approved plans and specifications. (Signature of senior Civil Engineer, only if approplate) Reference: Building Permit No. - -- --- j 00 loate !Date) Special Note: Submit this form, if completed, 10 counter staff merely by placing a copy of it in both engineering technicians' in- boxes. Please remember to do a final inspection of the grading permit and submit that paperwork, when completed. Office staff will handle the appmpiate reductions in security, if any, and coordination with Building Inspection. Thank you. ISG /field3.doc1 760 - 633 -2600 1 FAX 760 - 633 -2627 505 S. Vulcan Avenue. Encinitas. California 92024 -3633 TDD 7G0.633 -2700 1� recycled paper ENGINEERING SERVICES DEPARTMENT C'I1 Capital Improvement Projects 'J/ District Support Services Encinitas Field Operations Subdivision Engineering Traffic Engineering ROUGH GRADING APPROVAL TO: Subdivision Engineering Public Service Counter FROM Field Operations Private Contract Inspection RE: Grading Permit No. Sµ 52. Cal Name of Project I hE5 V Is S F_STAT-ES Name of Developer Site Location f "A RC' C L T ON L- J (address ...number ...street name I ...suffix) (Jot) (bldg) I have inspected the grading at the subject site and have verified certification of the pad by the Engineer of Work, Psi C_nr,n r it dated 5 - -- 17 - = -oE), and certification of soil compaction by the Soil Engineer, e , dated 1 —t7 —o. I am hereby satisfied that the rough grading has een completed in accordance with.othe approved plans and specifications, Chapter 23.24 of the Municipal Code, and any other applicable engineering standards and specific project requirements. Based on my observation and the certifications, I take no exception to the issuance of a building permit for the lot(s) as noted or Phase NJA, , if any, but only in so far as grading is concerned. However, this release is not intended to certify the project with respect to other engineering concerns, including public road, drainage, water, sewer, park, and trail improvements, and their availability, any other public improvements, deferred monumentation, or final grading. Prior to final inspection of the Building Permitls) and legal occupancy, I need to be further advised so that I can verify that final grading (i.e., finished precise grading, planting and irrigation) has been completed in accordance with the approved plans and specifications. r7 --- 15 --- O c l r5ate) — (Signature of Senior Civil Engineer, only if appropiate) (Date) Reference: Building Permit No. Special Note: Submit this form, if completed, to counter staff merely by placing a copy of it in both engineering technicians' in- boxes. Please remember to do a final inspection of the grading permit and submit that paperwork, when completed. Office staff will handle the appropiate reductions in security, if any, and coordination with building Inspection. Thank you. J SG /field3. doc I TEL 760 -633 -2600 ) FAX 760 - 633 -2627 505 S. Vulcan Avenue, Encinitas, California 92024 -3633 TDD 760-633 -2700 i� recycled paper 3c4olm August 10, 1998 Hans Jensen City Engineer City of Encinitas 505 South Vulcan Encinitas, CA 92024 RE: FINAL MAP (97 -201 TPM/E1A) iJM'%restrrieJMtas, lime. Dear Mr. Jensen: I — With refer to TPM 97 -201, 1 ould like to bring to your attention that the Final map has been in process at months. We have encountered inordinate delays in the Engineering Section. Simple things like covenants, which are standard boiler -plate stuff have taken nearly two months to get back from City Engineering. It is becoming apparent to me that maps which have come in after my map have been processed and finalized while my map languishes. I hope it is not because those developers badger the City staff and I don't. It would be quite sad, if that is the case. A case in point is that the final signed mylars and other documents (Pasco Engineering Transmittal is attached) have been submitted to the City but have not even found their way to the Plan Check person. Obviously, my map has not made it to the Planning Commission hearing on August 13, 1998, and 1 understand that the 27'" meeting has been canceled. I am requesting that you kindly look into this matter to ensure that all applicants get a fair shake as far as City Staffs response is concerned, and not just the squeaky wheel. I still believe that my map has been unnecessarily delayed. I would like some one responsible from your staff to please give me an idea of when they will look at the map, so that I may schedule matters accordingly. Sincerely, XION investments, Inc. Zach A. Abbas4 President ZA/pg Attachments CC: Wayne Pasco, RCE 131 souni escondldo boulevard a dido, caf fo is 92025 760/738-7555 760/738-7510 fax PASCO ENGINEERING 535 N Highway 101 Suite A ► SOLANA BEACH, CALIFORNIA 92075 (619) 259 -8212 Fax (619) 259.4812 TO " WE ARE SENDING YOU V'Attached ❑ Under separate cover via • Shop drawings ❑ Prints ❑ Plans • Copy of letter F! Change order ❑ DATE 7 xx3No. ATTENTION / RIE: - ❑ Samples the following items: ❑ Specifications COPIES DATE NO. DESCRIPTION - / rkr tin 14V_15 /�G�1(UO Ji 1X 04 . F( /r• _' 27Z s THESE ARE TRANSMITTED as checked below: pl7 ror approval �❑ For your use • As requested • For review and comment • FORBIDS DUE ❑ Approved as submitted • Approved as noted • Returned for corrections El • Resubmit copies for approval • Submit copies for distribution • Return corrected prints 19 ❑ PRINTS RETURNED AFTER LOAN TO US 7AZ 111A, COPY TO SIGNED: if enclosures am not as noted, kindly notify us at once. ROJECT FACILITY AV, . LABILITY Please type or use pen NIMAM ORG ZA1,10 9 4884T/ 7349 -7500 ACCT Owner's Name Phone ACT_ Ow y il s`ee s' �'.a — I TASK ne(s Maing Address Street City State Zip of lcinitas WATER V�� AMTS DISTRICT CASHIER'S USE ONLY F–SECTION 1. PROJECT DESCRIPTION TO BE COMPLETED BY APPLICANT I A. Major Subdivision (TM) 8 Specific Plan or Specific Plan Amendment Minor Subdivision (TPM) Certificate of Compliance: Boundary Adjustment Rezone (Reclassification) from _ Major Use Permit (MUP), purpose: Time Extension... Case No. Expired Map... Case No. Other W7i ■ r ■ ■ Residential .......Total number of dwelling units Commercial ...... Gross floor area Industrial........ Gross floor area Other ........... Gross floor area to zone. Assessor's Parcel Number(s) (Add extra it necessary) Z G 4 z o o O 3 I Thomas Bros. Page 1148 Grid R-4 C. Total Project acreage IS. 7Z Total number of lots Project address IT 94M 12�4N SaetRD D. Is the project proposing the use of groundwater? ❑Yes ZNo OUVEV 04IN ?WZ4 Is the project proposing the use of reclaimed water? ❑ Yes ® No Community Planning ArealSubregion Zip Owner/Applicant agrees to pay all necessary construction costs, dedicate all district required easements to extend service to the project and COMPLETE ALL CONDITIONS REQUIRED BY THE DISTRICT. Applicant's Signature: Date: Ar Address: MME A-S QMLAM? Phone; (On completion of above, present to the water district to establish facility availability, Section 2 below) • � • +�1'.a`'«71��.t= P3!IL''vlLs't�4Lr :�I District me L/ 1�4&W ��1A/ 11"Irr w. I/• Service area 1Inll It A. Project is in the district. ❑ Project is not in the district but is within its Sphere of Influence boundary, owner must a ply EEFIImG SERVICES ❑ Prc' .,t is not in the district and is no 'iihtn its Sphere of influence boundary. CITY OF ENCINITAS ❑ e project is not located entirel (thin the district and a potential boundary issue exists w the District. S. Facilities to serve the project ARE ❑ ARE NOT reasonably expected to be available within the next 5 years based on the capital facility plans of the district. Explain in space below or on attached _. (Number of slice's" ❑ �cw ' e served for the following reason(s): —. — C. ons are attached. N ur* �r of sheets attachnc':__ ❑ -�Istr:ct has specific water reclamation conditions which a :'e etta: tnd, umber of shFSts attai . z2d:_ —__ D.Vs;rici will sufrvnit conditions at a later date. ''rr opi�yr�Vl th5j�peline(s) have to ba9xtlypdy"rve the project" Dale: of is::uance unless disfricr indi, aces otherwise.) tame;�j! NOTE: THIS DOCG :IEN'i 'IS NOT A C314M7771ENT OF SERVICE 0:. FACILITIES ?Y THE DISTRICT. On completion of Section 2 by the district; i :; 2^ submit this form with application to the Zoning ::o_nter at the Planning S Community Development Dept., 527 Encinitas Blvd., Encinitas, CA 92024 CITY OF ENCINITAS INTEROFFICE MEMORANDUM w TO: (L wCiity Engineer, Engineering Department FROM: GIQAI6 0 1SorJ COMMUNITY QGVEL.OPMEN Department DATE: eo - //- 98 SUBJECT: Conditions of Approval 264-240 -30 (APN) E I L RAN C14 R DEVELOPMENT PL4NN 1/1G COA,(SUL%f}NTS (Owner) Please be advised that the COMMUNITY DEVE'LOPMEJVT Department conditions of Approval for Recordation of a Final Map for Project No. 7PM 47 -EO/ as required by Resolution No. PC 98 -05 have been satisfied. THIS MEMORANDUM MUST BE PROCESSED BY THE SUBDIVIDER, AND RETURNED TO THE PUBLIC WORKS DEPARTMENT. ( � �- - C� .1L, Siqnature m11808 OPEN S PAC-'e AseKtw T3 NoTtb orJ MAP 'CIF -4w rlc w n- AyrA04" � /u1, LA17-rJ 5EGµV-& D ON MA -Ac?i • L K- RECORDING REQUESTED BY: ) DISTRICT ENGINEER ) WHEN RECORDED MAIL TO: ) n CLERK OF THE BOARD CARDIFF SANITATION DISTRICT) 505 SOUTH VULCAN AVENUE ) ENCINITAS CA, 92024 ) THE ORIGINAL OF THIS DOCUIEHT GAS RECORDED ON OCT 22, 1999 DECUIENT NOW 1999 - 0709199 GUM J. SMITH, COUNTY RECORDER SAN DIEGO CUR RECORDER'S OFFICE TINE: 8:09 AN RELEASE OF COVENANTS REGARDING REAL PROPERTY: PUBLIC SEWER IMPROVEMENTS REQUIRED IN CONSIDERATION OF FINAL APPROVAL OF CERTAIN RELATED SUBDIVISIONS Assessor's Parcel No: Case #: various 264- 240 -02.03 Drawing #: various Permit #: various DCS Work Order #: various DCS Christopher S. Lloyd, in all, and Gregory Cleary, in part, subdividers, having entered into covenants for the benefit of the Cardiff Sanitation District ( "DISTRICT" hereinafter) which were recorded with the County Recorder of San Diego County, all as follows: Document Date Description Case Drawine 1991- 201875 05/02/91 annexations ... 87 -041 TM, 92- 035TPM, 92- 212TPM, 93- 029TM, 93- 053TPM, 97- 100TM, 97- 20ITPM, 97 -219TM main, laterals, appurtenances 92 -035 TPM CS -246 1994- 655404 11/10/94 main, laterals, appurtenances 93 -053 TPM CS -169 1996- 207398 04/25/96 main, laterals, appurtenances 93 -029 TM CS -202, and DISTRICT having determined that the obligations as set forth in said covenants have been fully and satisfactorily completed, DISTRICT hereby releases said covenants. Dated - ? o — q l ADA/jsg/re1L1oyd2.doc I CITY OF ENCINITAS by a&J - 01'414 Alan D. Archibald, P.E. Director of Engineering Services (Notarization required) CALIFORNIA ALL - PURPOSE ACKNOWLEDGMENT State of � U 2lcL County of n �r On �! 9 _before me b /� i . /� /LLx7n U/r' % f U 6U Ore _ Mime, ra Tft d OV1 le.y, -gene Ow. Nopry Pub" personally appeared (ts6rsonally known to me — OR — ❑ pr OFFICIAL SEAL RANDA G. MILUOUR NOTARY PUBLIC - CALIFORNIA COMM. NO. 1204250 SAN DIEGO COUNTY Y, - «• • MY COMM. EXP. JAN. 4 2003 )ved to me on the basis of hsfactory evidence to be the person(s) whose name(sre subscribed to the within instrument and acknowledged to me that Tie eRhey executed the 5&Te i hi r/their authorized capacity(ies), and that by Chi er/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument WITNESS my hand and official seal. r PMT - OPTIONAL Tbagh the ok— arlorr below rs nor regawed by fa w, ft may prove vak abb b pe9r99ona re&wg an Ora daiinenf and could pr V W haodFAcxrf removal and mIfradrnenl of dw, rornr No anothw d oa.nent Description of Attached Document Title or Type of Document: Document Date: Signer(s) Other Than Named Above: Capacity(ies) Claimed by Signer(s) Signer's Name: • Individual • Corporate Officer Tde(s): • Partner — ❑ Limited U General • Anomey -in -Fact • Trustee ❑ Guardian or Conservator ❑ Other Signer Is Representing: RIGHT THUMBPRINT OF SIGNER Number of Pages: Signer's Name: O Individual L I Corporate Officer Tine(s): ❑ Partner — ❑ Limited ❑ General U Attomey -in -Fact ❑ Trustee ❑ Guardian or Conservator U Other. Signer Is Representing: RIGHT TRUNBPRINT, O sIGNER 0 1994 N~al Noean A seoa1191 • 5296 Aem el Ave PO Box 1104 - Cano9a Pa& CAI 1309 F lea P,w No 5307 Reomer Ca Tae Fee 1 900 B 16 6�1 182 DOC 4 1998- 0596920 Recording Requested by: ) SEP 18, 1998 3:52 OFFICIAL RECORDS city of Encinitas ) SAN DIEGO COUNTY RECOW'S OFFICE GUM J. SMITH, GUM RECORDER When Recorded Mail To: ) FEFS: 47.00 City Clerk ) venue City of Encinitas. cCAlA92024 1) SF IIIIIIIIIIIIIIIIIIIIIIIIIIII 1996 - 0696920 PRIVATE ROAD AND DRAINAGE FACILITIES Q- MAINTENANCE AGREEMENT FOR TPM 97 -201 Assessor's Parcel No. 264- 240 -03 Project No.: TPM 97 -201 W. 0. No. • CS 272 THIS AGREEMENT for the maintenance and repair of that certain private road easement, the is set forth in Exhibits _ drainage facilities, the lE set forth in Exhibits hereof, is entered into by Corporation legal description and /or plat of which B attached hereto and those private :gal description and /or plat of which is C attached hereto and made a part XION INVESTMENTS, INC., a California (hereinafter referred to as "Developer ") for the benefit of future subdivision lot owners who will use the private road easement (hereinafter referred to as "lot owners ", which shall include the Developer to the extent the Developer retains any ownership interest in any lot or lots). WHEREAS, this Agreement is required as a condition of approval by the City of Encinitas of a subdivision project as defined in Section 21065 of the Public Resources code and pursuant to City of Encinitas Municipal Code Section 24.16.060 and Section 24.29.040; cov4173 1 0 za P IGINAL Of THIS DOCOKN' k,., ACORDED ON SEP 18, 1W8 MOCLWNT NUMBER 11M- 0596920 GREGORY J. SMITH, COWTY RECORDER Recording Requested by: ) SAN DIEGO COUNTY RECORDER'S OFFICE TIME: 3:52 PM City of Encinitas ) When Recorded Mail To: ) City Clerk ) City of Encinitas ) 505 S. Vulcan Avenue ) SPACE ABOVE FOR RECORDER'S USE Encinitas. CA 92024 1 PRIVATE ROAD AND DRAINAGE FACILITIES MAINTENANCE AGREEMENT FOR TPM 97 -201 Assessor's Parcel No. 264- 240 -03 Project No.: TPM 97 -201 W. 0. No.: CS 272 THIS AGREEMENT for the maintenance and repair of that certain private road easement, the legal description and /or plat of which is set forth in Exhibits B attached hereto and those private drainage facilities, the legal description and /or plat of which is set forth in Exhibits C attached hereto and made a part hereof, is entered into by Corporation XION INVESTMENTS. INC.. a California (hereinafter referred to as "Developer ") for the benefit of future subdivision lot owners who will use the private road easement (hereinafter referred to as "lot owners ", which shall include the Developer to the extent the Developer retains any ownership interest in any lot or lots). WHEREAS, this Agreement is required as a condition of approval by the City of Encinitas of a subdivision project as defined in Section 21065 of the Public Resources code and pursuant to City of Encinitas Municipal Code Section 24.16.060 and Section 24.29.040; cov4173 1 and, WHEREAS, Developer is the owner of certain real property being subdivided and developed as TPM 97 -201 that will use and enjoy the benefit of said road easement. A complete legal description of said real property is attached, labeled Exhibit A and incorporated by reference. Said real property is hereinafter referred to as the "property "; and WHEREAS, it is the desire of the Developer that said private road easement and drainage facilities be maintained in a safe and usable condition by the lot owners; and WHEREAS, it is the desire of the Developer to establish a method for the maintenance and repair of said private road easement and drainage facilities and for the apportionment of the expense of such maintenance and repair among existing and future lot owners; FRT:I WHEREAS, it is the intention of the Developer that this Agreement constitute a covenant running with the land, binding upon each successive lot owner of all or any portion of the property. NOW THEREFORE, IT IS HEREBY AGREED AS FOLLOWS: 1. The property is benefitted by this Agreement, and present and successive lot owners of all or any portion of the property are cov4173 2 expressly bound hereby for the benefit of the land. 2. The cost and expense of maintaining the private road easement and drainage facilities shall be divided equally among the subdivided parcels created in the subdivision and paid by the lot owner of the heirs, assigns and successors in interest or each such owner. 3. In the event any of the herein described parcels of land are subdivided further, the lot owners, heirs, assigns and successors in interest of each such newly created parcel shall be liable under this Agreement for their then pro rata share of expenses and such pro rata shares of expenses shall be computed to reflect such newly created parcels. 4. The repairs and maintenance to be performed under this Agreement shall be limited to the following unless the consent for additional work is agreed to by a majority vote of the lot owners owning 100% of the number of parcels, including subdivisions thereof as described in Paragraph 3 above: reasonable and normal road improvement and maintenance work to adequately maintain said private road easement and drainage facilities to permit all- weather access and conveyance of storm flows. Repairs and maintenance under this Agreement shall include, but is not limited to, filling of chuckholes, repairing cracks, repairing and resurfacing of roadbeds, repairing and maintaining drainage structures, removing cov4173 3 debris, maintaining signs, markers, striping and lighting, if any, and other work reasonably necessary and proper to repair and preserve the easement for all- weather road purposes. 5. If there is a covenant, agreement, or other obligation imposed as a condition of subdivision approval to make private road improvements to the private road easement, the obligation to repair and maintain the private road easement as herein set forth shall commence when the private road improvements have been completed and approved by the City. 6. Any extraordinary repair required to correct damage to said road easement or drainage facility that results from action taken or contracted for by lot owners or their successors in interest shall be paid for by the party taking action or party contracting for work which caused the necessity for the extraordinary repair. The repair shall be such as to restore the road easement or drainage facility to the condition existing prior to said damage. 7. It is agreed that Developer is initially the agent to contract and oversee and do all acts necessary to accomplish the repairs and maintenance required and /or authorized under this Agreement. Developer further agrees that the agent may at any time be replaced at the direction of a majority of the lot owners. Repair and maintenance work on the private road easement and cov4173 4 L drainage facilities shall be commenced when a majority of the lot owners agree in writing that such work is needed. The agent shall obtain three bids from licensed contractors and shall accept the lowest of said three bids and shall then initiate the work. The agent shall be paid for all costs incurred including a reasonable compensation for the agent's services, and such costs shall be added to and paid as a part of the repair and maintenance costs; provided, however, that compensation for the agent's services shall in no event exceed an amount equivalent to 10% of the actual cost of repairs and maintenance performed. In performing his duties, the agent, as he anticipates the need for funds, shall notify the parties and each party shall within forty -five (45) days pay the agent, who shall maintain a trustee account and also maintain accurate accounting records which are to be available for inspection by any party or authorized agent upon reasonable request. All such records shall be retained by the agent for a period of five years. 8. Should any lot owner fail to pay the pro rata share of costs and expenses as provided in this Agreement, then the agent or any lot owner or owners shall be entitled without further notice to institute legal action for the collection of funds advanced on behalf of such lot owner in accordance with the provisions of California Civil Code Section 845, and shall be entitled to recover in such action in addition to the funds advanced, interest thereon at the current prime rate of interest, until paid, all costs and cov4173 5 disbursements of such action, including such sum or sums as the Court may fix as and for a reasonable attorney's fees. 9. Any liability of the lot owners for personal injury to the agent hereunder, or to any worker employed to make repairs or provide maintenance under this Agreement, or to third persons, as well as any liability of the lot owners for damage to the property of agent, or any such worker, or of any third persons, as a result of or arising out of repairs and maintenance under this Agreement, shall be borne, as between the lot owners in the same percentages as they bear the costs and expenses of such repairs and maintenance. Each lot owner shall be responsible for and maintain his own insurance, if any. By this Agreement, the Developer does not intend to provide for the sharing of liability with respect to personal injury or property damage other than that attributable to the repairs and maintenance undertaken under this Agreement. Each of the lot owners agrees to indemnify the others from any and all liability for injury to himself or damage to his property when such injury or damage results from, arises out of, or is attributable to any maintenance or repairs undertaken pursuant to this Agreement. 10. Lot owners shall jointly and severally defend and indemnify and hold harmless City, City's engineer and its consultants and each of its officials, directors, officers, agents and employees from and against all liability, claims, damages, losses, expenses, personal injury and other costs, including costs cov4173 6 of defense and attorney's fees, to the agent hereunder or to any lot owner, any contractor, any subcontractor, any user of the road easement, or to any other third persons arising out of or in any way related to the use of, repair or maintenance of, or the failure to repair or maintain the private road easement or drainage facilities. Nothing in the Agreement, the specifications or other contract documents or City's approval of the plans and specifications or inspection of the work is intended to include a review, inspection acknowledgement of a responsibility for any such matter, and City, City's engineer and its consultants, and each of its officials, directors, officers, employees and agents, shall have no responsibility or liability therefore. 11. The foregoing covenants shall run with the land and shall be deemed to be for the benefit of the land of each of the lot owners and each and every person who shall at anytime own all or any portion of the property referred to herein. 12. It is understood and agreed that the covenants herein contained shall be binding on the heirs, executors, administrators, successors, and assignees of each of the lot owners. 13. It is the purpose of the signatories hereto that this instrument be recorded to the end and intent that the obligation cov4173 7 r hereby created shall be and constitute a covenant running with the land and any subsequent purchaser of all or any portion thereof, by acceptance of delivery of a deed and /or conveyance regardless of form, shall be deemed to have consented to and become bound by these presents, including without limitation, the right of any person entitled to enforce the terms of this Agreement to institute legal action as provided in Paragraph 8 hereof, such remedy to be cumulative and in addition to other remedies provided in this Agreement and to all other remedies at law or in equity. 14. The terms of this Agreement may be amended in writing upon majority approval of the lot owners and consent of the City. 15. This Agreement shall be governed by the laws of the State of California. In the event that any of the provisions of this Agreement are held to be unenforceable or invalid by any court of competent jurisdiction, the validity, and enforceability of the remaining provisions shall not be affected thereby. 16. If the Property constitutes a "Common Interest Development" as defined in California Civil Code Section 1351(c) which will include membership in or ownership of an "Association" as defined in California Civil Code Section 1351(a), anything in this Agreement to the contrary notwithstanding, the following provisions shall apply at and during such time as (i) the Property is encumbered by a "Declaration" (as defined in California Civil cov4173 8 Code Section 1351(h) , and (ii) the Common Area of the property (including the private road easement) is managed and controlled by an Association: (a) The Association, through its Board of Directors, shall repair and maintain the private road easement and drainage facilities and shall be deemed the "agent" as referred to in Paragraph 7 above. The Association, which shall not be replaced except by amendment to the Declaration, shall receive no compensation for performing such duties. The costs of such maintenance and repair shall be assessed against each owner and his subdivision interest in the Property pursuant to the Declaration. The assessments shall be deposited in the Association's corporate account. (b) The provisions in the Declaration which provide for assessment liens in favor of the Association and enforcement thereof shall supersede Paragraph 8 of the Agreement in its entirety. No individual owners shall have the right to alter, maintain or repair any of the Common Area (as defined in California Civil Code Section 1351(b) in the Property except as may be allowed by the Declaration. (c) This Agreement shall not be interpreted in any manner which reduces or limits the Association's rights and duties pursuant to its Bylaws and Declaration. cov4173 9 IN W77ITTNESS WHEREOF, the parties have executed this Agreement on the G �� day of U 19 98 Developer: etzz-� 11 �f X r 0A.) /ail -L_ Signature of DEVELOPER must be notarized. Attach the appropriate acknowledgement. cov4173 10 CALIFORNIA ALL- PURPOSL ;KNOWLEDGMENT State of :,> 59C County of (Sa fi3 i(La Q On 7- Z2 98 before me, JQt �. (✓�l (cruqk GATE � ' , I NAME. TITLE OF OFFICER - G..'JANE OOE, NOT RY UBLIC" personally appeared SI , NAN IS) OF SIGNERIS) ❑ personally known to me - OR proved to me on the basis of satisfactory evidence to be the person whose name( is /� subscribed to the within instrument and ac- knowledged to me that he /sl%�/tt' executed the same in his / r authorized _ @MYN JANEiG.MCCO07861 ca acit and that b his / r it S Commuson /1078681 P y ( Y t otary Public — COIit 8No $on o�ego cov,ty signature(`s,`on the instrument the person Comm E&Pres Nov 29 .190 or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. • SIGNAT RE OF NOTARY OPTIONAL Though the data below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent reattachment of this form. CAPACITY CLAIMED BY SIGNER ❑ INDIVIDUAL CORPOEjATE OFFICER TITLE(S) ❑ PARTNER(S) ❑ LIMITED GENERAL ❑ ATTORNEY -IN -FACT ❑ TRUSTEE(S) ❑ GUARDIAN /CONSERVATOR ❑ OTHER: SIGNER IS REPRESENTING: NA OF PERSON(S)O ENTITY(IES) DESCRIPTION OF ATTACHED DOCUMENT TITLE OR TYPE OF Fey Tfm 9-7 -2-z1 Lo NUMBER OF PAGES �.LZ la DA YE OF DOCUMENT SIGNER(S) OTHER THAN NAMED ABOVE 01993 NATIONAL NOTARY ASSOCIATION - 8236 Rommel Ave., P.O. Box 7184 - Canoga Park, CA 91309 -7184 EXHIBIT "A" LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. EXH I B IT B el 01 a a t N qp p J 1f' �7• A.199.54' R- 1000.00' 9.43- el-- - - - - - - - - - - - - - - - - �a 1 Z66. l 12 20� b/ 25 00' � ?S v 00• PROPOSED WIDE ROAD EASEMENT ?'so• �' PARCEL 4 12' NOT A PART N34 *26'02 . E 49' ml j I 51. g9' K8Q'14_52'E(R) N68'17_37'E (R) \ vIW IN N3 2'26'02'E 8.7 ' `6► / \ J \moo ?' . }0r er rirr 0901 P i� � r -C13' \ \ •29 01 � OHO` �' � � °° 29' +Z0 / '1r h s7 PARCEL 2 43 OP CURVE DELTA ARC RADIUS C1 85'16'03' 36.69' 26.00' C2 91144116" 41.63' 26.00' C3 18'00'15 66.77' 212.50' C4 16'45'27' 54.84' 187.50' C5 50'44'24• 17.71' 20.00' C6 65'28'25• 22.85' 20.00' C7 130'13'22' 90.91' 40.00' CS 36'39'44' 25.60' 40.00' C9 126'55'17' 88461' 40.00' CIO 08'58'19• 33.28' 212.50' LS1 12'3051" 46.41' 212.50' C12 40.38 "10' 53.55' 75.50' C13 74.50'39' 90.99' 69.66' C14 20'30'02" 95.81' 267.79' Effi JT °C" FOR DETAILS OF PRIVATE DRAINAGE FACILITIES SEE CITY OF ENCINITAS GRADING PLAN 5452-G Recording requested by: When Recorded Mail To: District Clerk ) Cardiff Sanitation District ) 505 South Vulcan Avenue ) Encinitas, CA 92024 ) THE u_Ak OF THIS DOD" 6% RECORDED ON SEP 18, 19% D0 Eff on 1998 -05 %918 REM J. SHITH, CUM RECOW SAN DIEGO CU Y RECORDER'S OFFICE TINE: 3:52 PS SPACE ABOVE FOR RECORDER'S USE COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY. Assessor's Parcel No. 264- 240 -03 A. XION INVESTMENTS, Inc., a California Corporation Project No.: TPM 97 -201 W. O. No.: CS 272 ( "SUBDIVIDER" hereinafter) is the owner of real property which is commonly known as TPM 97 -201 ( "PROPERTY" hereinafter) and which is described as follows: See Exhibit A which is attached hereto and made a part hereof. B. The tentative subdivision of the PROPERTY was approved with the final approval subject to certain conditions requiring the construction of improvements by SUBDIVIDER. SUBDIVIDER has applied for final approval of the subdivision but has not constructed the required improvements. In consideration of the final approval of the improvement plans for the required improvements by the Cardiff Sanitation District ( "DISTRICT" hereinafter), SUBDIVIDER hereby TF /03 /C0V2- 308wp51 1(4/26/91 -1) 10e15a 1 JAN 90 covenants and agrees for the benefit of DISTRICT, to do the following: See Exhibit B which is attached hereto and made a part hereof. C. This Covenant shall run with the land and be binding upon and inure to the benefit of the future owners, encumbrances, successors, heirs, personal representatives, transferees and assigns of the respective parties. D. SUBDIVIDER agrees that SUBDIVIDER's duties and obligations under this Covenant are a lien upon the PROPERTY. Upon notice and opportunity to respond, DISTRICT may add to the property tax bill of the PROPERTY any past due financial obligation owing to DISTRICT by way of this Covenant. E. If either party is required to incur costs to enforce the provisions of this Covenant, the prevailing party shall be entitled to full reimbursement of all costs, including reasonable attorneys' fees, from the other party. F. Failure of SUBDIVIDER to comply with the terms of this Covenant shall constitute consent to the filing by DISTRICT of a Notice of Violation of Covenant. G. Upon SUBDIVIDER's satisfactory completion of SUBDIVIDER's duties and obligations contained herein, SUBDIVIDER may request and DISTRICT shall execute a Satisfaction of Covenant. H. By action of the Board of Directors, DISTRICT may assign to a person or persons impacted by the performance of this Covenant, the right to enforce this Covenant against SUBDIVIDER. TF /03/COV2- 308wp51 2(4/26/91 -1) 10el5a 1 JAN 90 ACCEPTED AND AGREED. Dated SUBDIVIDER Dated 7-2-Z- 9a X/oni (Notarization of SUBDIVIDER signature is attached.) CARDIFF SANITATION DISTRICT Dated by C Q a Clerk of the Board (Notarization not required) TF /03/COV2- 308Wp51 3(4/26/91 -1) 10e15a 1 JAN 90 CALIFORNIA ALL- PURPOACKNOWLEDGMENT State of Cai I I I CT /l f a. County of 3oLn ZD I qqc) On 7-122 -l(clg before me, jo_f)e�'- r . MGC°r�f�ovah DA _ , A r I NAME, TITLE OF OFFICER - EA, DOE. NOTARY P personally appeared NAME(S) OF SIGNER(S) N. s3m ❑ personally known to me - OR >i_5* roved to me on the basis of satisfactory evidence to be the personN whose name�is /N my G. MC COUOUGN < Comms�ion ♦10)pIS61 i o v Ablk — Cad(OR11a i San Oego Colnty W Comm. Exoirea Nov Z9, 1999 subscribed to the within instrument and ac- knowledged to me that he /s'1v�/Qy executed the same in his /Rant Zrr authorized capacity(iN, and that by hisNrq; /� signatureN on the instrument the personX or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. • SIGNAT RE OF NOTARY OPTIONAL Though the data below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent reattachment of this form. CAPACITY CLAIMED BY SIGNER ESCRIPTI N QF ATTACHED DOCU ENT ❑ INDIVIDUAL o CORPOR TE OFFICER ��,r� �I �r�s�e�i— f 5e nnHSl TITLE OR TYPE OF DOCUM NT ❑ PARTNER(S) ❑ LIMITED ❑ GENERAL ATTORNEY -IN -FACT TRUSTEE(S) GUARD IAN /CONSERVATOR OTHER: SIGNER IS REPRESENTING: N EO PERSON(SIOR ITY(IES) G 1+ NUMBER OF PAGES - ZZq"`18 DATt OF DOCUMENT SIGNER(S) OTHER THAN NAMED ABOVE 01993 NATIONAL NOTARY ASSOCIATION -8236 Remmet Ave.. P.O. Box 7184 -Canoga Park, CA 913D9.7184 ATTACHMENT A TO COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY. PROJECT NO. TPM 97 -201 PROPERTY DESCRIPTION LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. TF /03 /COV2- 308wp51 4(4/26/91 -1) 10e15a 1 JAN 90 ATTACHMENT B TO COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY. PROJECT NO. TPM 97 -201 SUBDIVIDER's DUTIES AND OBLIGATIONS Name of SUBDIVIDER: XION INVESTMENTS. INC. a California Corporation Tract or Parcel Map Number TPM 97 -201 Name of Subdivision: _Abbasi Development Resolution of Approval Number: PC 98 -05 Adopted: January 8, 1998 Estimated total cost of improvements: * 28, e>3(0_ --_ 1.0 IMPROVEMENTS REQUIRED 1.1 SUBDIVIDER agrees at SUBDIVIDER's own cost and expense to furnish all the labor, equipment and materials to perform and complete, in accordance with the plans and specifications and to the satisfaction and approval of the District Engineer, all of the improvements referred to below: Improvement plans for TPM 97 -201 sheets 1 through 1 , dated and prepared by Pasco Engineering , as approved on c)-j5—c)8 by the District Engineer together with any subsequent amendments approved in writing by the District Engineer; on file with DISTRICT in the District Office and incorporated herein as though fully set forth at length. 1.2 Further, SUBDIVIDER agrees to perform the following conditions: TF /03 /COV2- 308wp51 5(4/26/91 -1) 10e15a 1 JAN 90 RESOLUTION CONDITIONS: 2.0 PROGRESS OF WORK 2.1 Time is of the essence with this Covenant. SUBDIVIDER shall commence substantial construction of the improvements required by this Covenant not later than 1-01- Zo01 and shall complete the improvements no later than 10 -OI -2 00t In the event good cause exists, as determined by the District Engineer, the time for commencement of construction or completion of the improvements hereunder may be extended. Any such extension may be granted without notice to SUBDIVIDER's Surety or Sureties, if any, and shall in no way affect the validity of this Covenant or release the Surety or Sureties on any security given for the faithful performance of this Covenant. The District Engineer shall be the sole and final judge as to whether or not good cause has been shown to entitle SUBDIVIDER to an extension. As a condition of such extensions, the District Engineer may require SUBDIVIDER to furnish new security guaranteeing performance of this Covenant, as extended, in an increased amount as necessary to compensate for any increase in construction costs as determined by the District Engineer. 2.2 If any of the public improvements are to be constructed or installed on land not owned by SUBDIVIDER, no construction or installation shall be commenced prior to the acquisition and TF /03 /COV2- 308wp51 6(4/26/91 -1) 10e15a 1 JAN 90 acceptance by DISTRICT of appropriate property interests. SUBDIVIDER shall pay the actual costs of acquisition of such property interests. 2.3 SUBDIVIDER shall, at SUBDIVIDER's expense, obtain all necessary permits and licenses for the construction of the improvements and give all necessary notices and pay all fees and taxes required by law. 2.4 SUBDIVIDER shall notify the District Engineer in writing at least 15 days prior to the commencement of work hereunder. No construction work shall begin until authorized by DISTRICT. 2.5 SUBDIVIDER shall not be entitled to obtain occupancy permits for the buildings constructed on any lot created by the subdivision until all required improvements have been provided to the satisfaction of the District Engineer. 2.6 SUBDIVIDER shall at all times maintain safe construction facilities, and provide safe access, for inspection by DISTRICT, to all parts of the work and to the shops wherein the work is in preparation. 2.7 SUBDIVIDER shall give good and adequate warning to the public to each and every existing danger relating to the construction of the improvements, and shall protect the public from such dangers. TF /03 /COV2- 308wp51 7(4/26/91 -1) 10e15a 1 JAN 90 3.0 INSPECTION /ACCEPTANCE OF IMPROVEMENTS 3.1 The District Engineer or his duly authorized representative, upon request of SUBDIVIDER, shall inspect, at SUBDIVIDER's expense, the improvements herein agreed to be constructed and installed by SUBDIVIDER. If determined to be in accordance with applicable DISTRICT standards and the other terms of this Covenant, the District Engineer shall approve the improvements and recommend the acceptance of the public improvements by DISTRICT through resolution of the Board of Directors of the Cardiff Sanitation District. 3.2 The SUBDIVIDER agrees to pay for each inspection of the improvements required by the District Engineer. 3.3 Approval of the improvements and acceptance of the public improvements by DISTRICT, shall not constitute a waiver by DISTRICT of any defects in the improvements. 3.4 Until such time as the improvements required by this Covenant are fully completed by SUBDIVIDER, approved by the District Engineer and the public improvements are accepted by DISTRICT, SUBDIVIDER will be responsible for the care, maintenance, repair and replacement of such public improvements. 4.0 GUARANTEE /WARRANTY 4.1 ONE YEAR. SUBDIVIDER hereby guarantees and warrants the public improvements constructed pursuant to this Covenant for a period of one year after final acceptance of said work to include design, work, labor and materials furnished. If within the one year period, any public improvement or part of any public improvement furnished, installed or constructed, or caused to be furnished, installed or constructed by SUBDIVIDER, fails to fulfill TF /03 /COV2- 308wp51 8(4/26/91 -1) 10e15a 1 JAN 90 any of the requirements of this Covenant or otherwise fails to function to the satisfaction of the DISTRICT, SUBDIVIDER shall without delay and without any cost to DISTRICT, repair, replace or reconstruct any failing part or parts of the public improvement. 4.2 TEN YEARS. For ten years following the acceptance by DISTRICT of the public improvements, SUBDIVIDER shall remain obligated to cure all identified defects in the design, construction, materials of the public improvements. 5.0 SECURITY 5.1 FOR CONSTRUCTION OF IMPROVEMENTS A. Prior to the sale or transfer of all or any portion of this Subdivision, or prior to the issuance of any development permits for this Subdivision, SUBDIVIDER shall furnish to DISTRICT good and sufficient security in the form of a cash deposit, letter of credit, or other security as approved by the District Engineer in the amount of 150% of the then - current estimate of the construction costs of the improvements to assure faithful performance of this Covenant. B. In the event that changes, alterations or additions to the improvement plans and specifications or to the improvements add 10% or more to the original estimated costs of the improvements, SUBDIVIDER shall provide additional security in a form satisfactory to DISTRICT in an amount equal to 100% of the total estimated increase in the construction cost of the improvements. The amount of the additional security may be adjusted by the amount of work completed and any prior, partial releases of security. 5.2 FOR ONE YEAR GUARANTEE /WARRANTY. SUBDIVIDER shall TF /03/COV2- 308wp51 9(4/26/91 -1) 10e15a 1 JAN 90 furnish to DISTRICT good and sufficient security, in the form of a cash deposit, letter of credit or other security as approved by the City Engineer, in the amount of 25% of the estimated total cost of the public improvements, to secure SUBDIVIDER's guarantee and warranty specified herein for a period of one year following the acceptance by DISTRICT of the public improvements. 6.0 CURING OF DEFAULTS 6.1 In the event that SUBDIVIDER fails to perform any duty or obligation imposed by this Covenant, SUBDIVIDER hereby authorizes DISTRICT, at DISTRICT's option, to perform such duty or obligation twenty (20) days after DISTRICT mails written notice of default to SUBDIVIDER and SUBDIVIDER fails to cure such default. SUBDIVIDER agrees to pay the actual costs of such performance by DISTRICT. The security posted by SUBDIVIDER pursuant to this Covenant may be used by DISTRICT for the completion of such performance, but shall not limit SUBDIVIDER's liability. 6.2 In the event of SUBDIVIDER'S uncured default, DISTRICT may take over the work and prosecute the same to completion, by contract or by any other method DISTRICT may deem advisable, for the account and at the expense of SUBDIVIDER. SUBDIVIDER shall be liable to DISTRICT for the actual costs or damages occasioned DISTRICT thereby. Without liability for so doing, DISTRICT may take possession of the construction site and the work. In completing the work, DISTRICT may utilize such materials, appliances, plants and other property belonging to SUBDIVIDER as may be on the site of the work and necessary therefore. 6.3 Should the exigencies of the case require repairs, replacements, or work to be done before SUBDIVIDER can be notified TF /03/COV2- 308wp51 10(4/26/91 -1) 10e15a 1 SAN 90 and given 20 days to perform, DISTRICT may, at DISTRICT's option and without liability, make the necessary repairs or replacements or perform the necessary work and SUBDIVIDER shall pay to DISTRICT the actual costs of so doing. 7.0 HOLD HARMLESS 7.1 SUBDIVIDER agrees to indemnify and hold DISTRICT and DISTRICT's officers, officials, employees and agents harmless from, and against any and all liabilities, claims, demands, causes of action, losses, damages and costs, including all costs of defense thereof, arising out of, or in any manner connected directly or indirectly with, any acts or omissions of SUBDIVIDER or SUBDIVIDER's agents, employees, subcontractors, officials, officers or representatives. Upon demand, SUBDIVIDER shall, at its own expense, defend DISTRICT and DISTRICT's officers, officials, employees and agents, from and against any and all such liabilities, claims, demands, causes of action, losses, damages and costs. 7.2 SUBDIVIDER's obligation herein includes, but is not limited to, alleged defects in the plans, specifications and design of the improvements; but does not extend to liabilities, claims, demands, causes of action, losses, damages or costs that arise out of a defect in the plans, specifications or design that is a result of a change required by DISTRICT to the SUBDIVIDER's proposed plans, specifications or design so long as such change is objected to, in writing, by the SUBDIVIDER, and the writing is filed with the District Engineer more than ten days prior to the commencement of work. 7.3 SUBDIVIDER's obligation herein includes, but is not TF /03/COV2- 308wp51 11(4/26/91 -1) 10e15a 1 SAN 90 limited to, alleged defects in the construction of the improvements; alleged defects in the materials furnished in the construction of the improvements; alleged injury to persons or property; alleged inverse condemnation of property or a consequence of the design, construction, or maintenance of the work or the improvements; and any accident, loss or damage to the work or the improvements prior to the acceptance of same by DISTRICT. 7.4 By approving the improvement plans, specifications and design; by inspecting or approving the improvements; or by accepting the public improvements, DISTRICT shall not have waived the protections afforded herein to DISTRICT and DISTRICT's officers, officials, employees and agents or diminished the obligation of SUBDIVIDER who shall remain obligated in the same degree to indemnify and hold DISTRICT and DISTRICT's officers, officials, employees and agents, harmless as provided above. 7.5 SUBDIVIDER's obligation herein does not extend to liabilities, claims, demands, causes of action, losses, damages or costs that arise out of DISTRICT's intentional wrongful acts, DISTRICT's violations of law, or DISTRICT's sole active negligence. TF /03/COV2- 308wp51 12(4/26/91 -1) 10e15a 1 JAN 90 8.0 INSURANCE 8.1 The SUBDIVIDER shall obtain and maintain a policy of motor vehicle liability, public liability, general liability and property damage insurance from an insurance company approved by DISTRICT and authorized to do business in the State of California, in an insurable amount of not less than one million dollars ($1,000,000.00) for each occurrence or aggregate. The insurance policy shall provide that the policy shall remain in force during the life of this COVENANT and shall not be canceled, terminated, or allowed to expire without thirty (30) days prior written notice to DISTRICT from the insurance company. 8.2 DISTRICT shall be named as an additional insured on SUBDIVIDER's policies. 8.3 SUBDIVIDER shall furnish certificates of said insurance to DISTRICT prior to commencement of work under this AGREEMENT. 9.0 NOTICES 9.1 Any notices to be given under this COVENANT, or otherwise, shall be served by certified mail. 9.2 For the purposes hereof, unless otherwise provided in writing by the parties hereto, the address of DISTRICT and the proper person to receive any such notice on its behalf is: District Engineer Cardiff Sanitation District 505 South Vulcan Avenue Encinitas, CA 92024 and the address of SUBDIVIDER and the proper person to receive any such notice on its behalf is: TF /03/COV2- 308wp51 13(4/26/91 -1) 10e15a 1 JAN 90 10.0 SUBDIVIDER'S CERTIFICATION OF AWARENESS OF IMMIGRATION REFORM AND CONTROL ACT OF 1986 SUBDIVIDER certifies that SUBDIVIDER is aware of the requirements of the Immigration Reform and Control Act of 1986 (8 USC SS 1101 -1525) and will comply with these requirements, including but not limited to verifying the eligibility for employment of all agents, employees, subcontractors and consultants that are included in, satisfy the duties and obligations contained herein. 11.0 GENERAL PROVISIONS 11.1 Neither SUBDIVIDER nor any of SUBDIVIDER's agents or contractors are or shall be considered to be agents of DISTRICT in connection with the performance of SUBDIVIDER's duties and obligations under this Covenant. 11.2 Sale or other disposition of the PROPERTY will not relieve SUBDIVIDER from the duties and obligations set forth herein. 11.3 SUBDIVIDER shall provide the improvements as an independent contractor and in pursuit of SUBDIVIDER's independent calling, and not as an employee of DISTRICT. SUBDIVIDER shall not be under control of the DISTRICT except as to the result to be accomplished. SUBDIVIDER may confer with DISTRICT as required to perform this Covenant. 11.4 No verbal agreement or conversation with any officer, official, agent or employee of DISTRICT, either before, during or after the execution of this Covenant, shall effect or modify any of the terms or obligations herein contained. TF /03/COV2- 308wp51 14(4/26/91 -1) 10e15a 1 JAN 90 THE -ANAL OF THIS DOCI1MEN1 WAS RECORDED ON SEP 18, 1998 DODJW KKR 1996-05 %919 (iiEW J. N% COU6Y IIFrn IFR n III CUP NEW'S WFICE When Recorded Mail To: ) , City Clerk ) City of Encinitas ) 505 South Vulcan Avenue ) Encinitas. CA 92024 1 SPACE ABOVE FOR RECORDER'S USE COVENANT REGARDING REAL PROPERTY FUTURE PARK, TRAFFIC, AND FLOOD CONTROL FEES Assessor's Parcel Number: 264 - 240 -03 Project No. TPM 97 -201 A. %ION INVESTMENTS, INC., A California Corporation ( "OWNER" hereinafter) is the owner of real property which is commonly known as TPM 97 -201, ( "PROPERTY" hereinafter) and which is legally described as follows: See Attachment "A" which is attached hereto and made a part hereof. B. In consideration of Final Map approval for the above referenced project by the City of Encinitas ( "CITY" hereinafter), OWNER hereby covenants and agrees for the benefit of CITY, to do the following: See Attachment "B" which is attached hereto and made a pan hereof. C. This Covenant shall run with the land and be binding upon and inure to the benefit of the future owners, encumbrancers, successors, heirs, personal representatives, transferees and assigns of the respective parties. D. OWNER agrees that OWNER'S duties and obligations under this Covenant are a lien upon the PROPERTY. Upon notice and opportunity to respond, CITY may add to the property tax bill of the PROPERTY any past due financial obligation owing to CITY by way of this Covenant. E. If either party is required to incurs costs to enforce the provisions of this Covenant, the prevailing party shall be entitled to full reimbursement of all costs, including reasonable attorney's fees, from the other party. F. Failure of the OWNER to comply with the terms of this Covenant shall constitute consent to the filing by CITY of a Notice of Violation of Covenant. cov5940 bak 7/14/98 .444 VINQu6M44MMARtisfaction of OWNER's duties and obligations contained herein, OWAM : IQPMI execute a "Satisfaction of Covenant ". H. By action of the City Council, CITY may assign to a person or persons impacted by the performance of this Covenant, the right to enforce this Covenant against OWNER. MV— SM10 WAN "FAMci W03 OWNER Dated 1 lk x i o u 1AvjfC7-A eF- TS t N c Dated P '3.,4rLr-NT .SEL (Notarization of OWNER signature is attached) ATTACH NOTARY HERE CITY OF ENC`INIIT�AASSS Dated . lS �`71` by (Notarizati6n not re uired) 7A7�tK @x�tl►t9G}[EI$Yt7ti5iblE�Tr Bill Weedman, City Planner cov5940 bak 7/14/98 CALIFORNIA ALL- PURPOACKNOWLEDGMENT State of Ct1t)5IF6a- County of ��lJt!qqU I I I I On �" Z before me, d) net & m C co u o u g I_ f 1 ATE I A I I NAME, TITLE OF OFFICER - E,G.,'JANE DOE, NOTARY BLIC' personally appeared NAME(S) OF SIGNER(S) No 55,7 ❑ personally known to me - OR - 'proved to me on the basis of satisfacto evidence to be the person whose name(( s/ Iv,,e subscribed to the within instrument al d ac- knowledged to me that he /s/tiheyr executed the same in his Ir authorized comet "'c, ;° 70681" capacit �, and that by his7hwl/� r -� Notary Public — California signature on the instrument the person son Olepo County f+ty Comm. Exdrallov 29. IM or the entfly upon behalf of which the person (s acted, executed the instrument. WITNESS my hand and official seal. C (9L SIGNATNR F NOTARY OPTIONAL Though the data below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent reattachment of this form. CAPACITY CLAIMED BY SIGNER ❑ INDIVIDUAL CORPORA T OFFICER TITLEISI ❑ ARTNER(S) ❑ LIMITED ❑ GENERAL IS ATTORNEY -IN -FACT TRUSTEE(S) GUARD IAN /CONSERVATOR OTHER: SIGNER IS REPRESENTING- N ME PERSON(S) OR NTITY(IES) DE_ SUIPTIDN QF A3TACHEILDOCUMIPT _ �.p�'lAn�� j�a .4 TITLE OR TYPE OF DOCUMENT Fill W NUMBER OF PAGES 7/z2_/9 ?:) DATE O DOCUMENT SIGNER(S) OTHER THAN NAMED ABOVE 01993 NATIONAL NOTARY ASSOCIATION • 8236 Remmet Ave.. P.O. Boa 7184 • Canoga Park, CA 913097184 ATTACHMENT "A" TO COVENANT REGARDING REAL PROPERTY PROJECT NO. TPM 97 -201 LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. cov5940 bak 7/14/98 PROPERTY DESCRIPTION ATTACHMENT "B" TO COVENANT REGARDING REAL PROPERTY PROJECT NO. TPM 97 -201 OWNER'S DUTIES AND OBLIGATIONS A. In accordance with Municipal Code Chapter 23.98 in effect at time of fees being paid, park fees for the development shall be paid prior to Final Occupancy approval. B. In accordance with the Municipal Code Chapter 23.94 in effect at time of fees being paid, traffic fees for the development shall be paid prior to Final Occupancy approval. C. In accordance with the Municipal Code Chapter 23.96 in effect at time of fees being paid, flood control fees shall be assessed and collected during the building permit processing prior to the construction of any impervious surfaces. cov5940 bak 7/14/98 T It TRANSMITTAL FORM ENGINEERING SERVICES DEPARTMENT F R Capital Improvements n Field Operations El O Subdivision Engineering Office of the Director El M District Support Services El Traffic Engineering El T q/W111 %Y Uate: �Z O / �/ r A /N�- Re T g: (Finance Numb EE/ EPOSIT UP/MIN/DR: ATTENTION: A.P.N.: Transmitted as following: Comments/Additional Space for Document Final Parcel Map ❑ Final Map [j Check(s) • 9e�j • 4*5 1 .16 Checkprint(s) / Approved Copy / Original(s) / Certificate OF TK15 YWYMt q Traverse Calculations ❑ Reference Maps ❑ Plancheck Comments ❑ Easement re: Covenant re: Agreement re: tN� A- otf12 LAC rY Gr y;�Check(s) eckApproved Copal(s) Plancheck Comments alculations ❑ Cost Estimate Hydrology Study /Map E] Soil Report ❑ Sketch (if needed): L—FLEPLy: K(O-r kr 7'Al5 TKt,/ Artz rr(wJXZP -lo Sctl9*rr AMP RE•-e.t E VI- AFprL FDh o ut<- Improvement Plan E] Check(s) Checkprint(s) /Approved Copy /Original(s) Plancheck Comments Structural Calculations ❑ Cost Estimate ❑ PRLOK `io P- ^Uf*NCE ap Hydrology Study/Map El Cross Sections El '7►(Y. As Per... our conversation My /your inquiry Our Review O Our Inquiry For your..conection Comment IH Signature _ j], Information ❑ Uses C] Please return Please call:� if necessary Originator: e pa Copies to: r / V Messenger ❑ Mail Ej Fascimile D Other ❑ I Received by: Date: A Title: Location: Telephone: 505 South Vulcan Avenue, Encinitas, California 92024 -3633 TEL (619) 633 -2600 1FAX (619) 633 -2627 / TDD (619) 633 -2700 954.doc(10- 03 -95) CITY OF ENCINITAS CARDIFF SANITATION DISTRICT 1._ : Ufflo 1 Meeting Date: August 26, 1998 TO: Cardiff Sanitation District Board of Directors =`.)R YOUR RECORDS VIA: �°. Lauren M. Wasserman, District Manager �rnrnckyc" FROM: , e/ �Alan Archibald, Director of Engineering Services Hans Jensen, Senior Subdivision Engineer SUBJECT: Acceptance of sewer easements as dedicated on the final parcel map of TPM 97- 201 into the Cardiff Sanitation District and authorize the Clerk of the Board to sign the final parcel map. Subject property is Lot 6 of Map No. 13320, located on the south side of Double LL Ranch Road between Calle Margarita and Lone Jack Road. (APN:264- 240-03) Applicant: Xion Investments, Inc. BACKGROUND: On January 8, 1998, the Planning Commission approved, subject to conditions, Tentative Parcel Map No. 97 -201, a tentative parcel map of a subdivision creating 4 single family residential lots in excess of 2 acres each and a remainder parcel in the Olivenhain area. ( Resolution No. 98 -05 ) To serve this project the subdivider has offered to dedicate a public sewer main and easement to the Cardiff Sanitation District. The sewer main will be constructed to district standards. ANALYSIS: An easement has been granted to the Cardiff Sanitation District on the final parcel map for construction, maintenance, and repair of sewer structures. A covenant has been executed by the subdivider to ensure the proposed sewer improvements are constructed, installed and inspected in conformance with district standards for public sewer mains. It is recommended that the Board of Directors accept the sewer easement into the Cardiff Sanitation District and authorize the Clerk of the Board to sign the final map. BAK AR5959.doe 08 -18 -98 CITY OF ENCINITAS AGENDA REPORT PLANNING COMMISSION Meeting Date: September 10, 1998 TO: /Planning Commission VIA: /�,/ Bill Weedman, City Planner FROM: Alan Archibald, Director of Engineering Services I *Hans Jensen, Senior Subdivision Engineer SUBJECT: Approval of the Final Parcel Map which conforms to Tentative Parcel Map No. 97 -201. Subject property is Lot 6 of Map No. 13320, located on the south side of Double LL Ranch Road between Calle Margarita and Lone Jack Road. (APN:264- 240 -03) Applicant: Xion Investments, Inc. BACKGROUND: On January 8, 1998, the Planning Commission approved, subject to conditions, Tentative Parcel Map No. 97 -201, a tentative parcel map of a subdivision creating 4 single family residential lots in excess of 2 acres each and a remainder parcel in the Olivenhain area. ( Resolution No. 98 -05 ) The final map has been examined and found to be technically correct and in compliance with State laws and City ordinances. The Tentative Parcel Map is scheduled to expire on January 8, 2000. All conditions of approval have been complied with prior to the expiration date. RECOMMENDATION: It is recommended that the Planning Commission take the following actions: Approve the Final Map which conforms to Tentative Map No. 97 -201 and authorize the City Treasurer and the Secretary of the Planning Commission to sign the map. 2. Authorize the recordation of the Final Parcel Map which conforms to Tentative Parcel Map No. 97 -201 after the mandatory ten calendar day appeal period. bak AR5965.doc 08 -31 -98 DESCRIPTION: Public Hearing to consider a Design Review Permit and a Coastal Development Permit to allow the construction of three two -story single family dwellings which range from 2500 to 2700 square feet. MUTLT'110 1 Ala In q STATUS: The project is categorically exempt from environmental review pursuant to Section 15303(a) of the California Environmental Quality Act (CEQA) Guidelines. Added by B.A. Knoll 8 -27 -98 for the 9 -10 -98 meeting: (Consent) 8. CASE NUMBER: 96 -185 TM/MUP /CDP FILING DATE: January 26, 1998 APPLICANT: Daniel T. Shelley LOCATION: 1573 South El Camino Real (APN: 260 - 072 -35). DESCRIPTION: Approval of the Final Map which conforms to Tentative Map No. 96 -185 ENVIRONMENTAL STATUS: A fmal Environmental Impact Report (EIR) was certified by the Planning Commission of the City of Encinitas on June 23, 1997 (Resolution No. PC- 97-40) and an Addendum to the EIR on September 25, 1997. Added by B.A. Knoll 8- 1 98 for the 9 -10 -98 meeting: (Consent) 9. CASE NUMBER: 97 -201 TPM/EIA FILING DATE: March 9, 1998 APPLICANT: Xion Investments, Inc. LOCATION: Lot 6 of Map No. 13320, Located on the south side of Double LL Ranch Road between Calle Margarita and Lone Jack Road. (APN: 264 - 240 -03). DESCRIPTION: Approval of the Final Parcel Map which conforms to Tentative Parcel Map No. 97 -201 ENVIRONMENTAL STATUS: An Environmental Initial Assessment (EIA) was completed and approved by the Planning Commission of the City of Encinitas on January 8, 1998 (Resolution No. PC- 98 -05). MEETING OF SEPTEMBER 24,1998 Added by C. Olson August 4, 1998, for the meeting of September 24, 1998: 1. CASE NUMBER: 98 -039 MUP/ DR/CDP/EIA FILING DATE: February 17, 1998 APPLICANT: Kathleen Porterfield / Encinitas Country Day School LOCATION: 3616 Manchester Avenue (APN: 262- 073 -24). DESCRIPTION: Public Hearing to consider a Major Use Permit, Design Review Permit, and a Coastal Development Permit to allow the construction of a 42,144 CITY OF ENCINITAS CARDIFF SANITATION DISTRICT AGENDA REPORT Meeting Date: August 26, 1998 TO: Cardiff Sanitation District Board of Directors VIA: 7. Lauren M. Wasserman, District Manager FROM:/ Alan Archibald, Director of Engineering Services vJ{C Hans Jensen, Senior Subdivision Engineer SUBJECT: Acceptance of sewer easements as dedicated on the final parcel map of TPM 97- 201 into the Cardiff Sanitation District and authorize the Clerk of the Board to sign the final parcel map. Subject property is Lot 6 of Map No. 13320, located on the south side of Double LL Ranch Road between Calle Margarita and Lone Jack Road. (APN:264- 240 -03) Applicant: Xion Investments, Inc. BACKGROUND: On January 8, 1998, the Planning Commission approved, subject to conditions, Tentative Parcel Map No. 97 -201, a tentative parcel map of a subdivision creating 4 single family residential lots in excess of 2 acres each and a remainder parcel in the Olivenhain area. ( Resolution No. 98 -05 ) To serve this project the subdivider has offered to dedicate a public sewer train and easement to the Cardiff Sanitation District. The sewer main will be constructed to district standards. ANALYSIS: An easement has been granted to the Cardiff Sanitation District on the final parcel map for construction, maintenance, and repair of sewer structures. A covenant has been executed by the subdivider to ensure the proposed sewer improvements are constructed, installed and inspected in conformance with district standards for public sewer mains. RECOMMENDATION: It is recommended that the Board of Directors accept the sewer easement into the Cardiff Sanitation District and authorize the Clerk of the Board to sign the final map. BAK AR5959.doc 08 -18 -98 TRANSMITTAL FORM ENGINEERING SERVICES DEPARTMENT F R Capital Improvements ❑ Field Operations O Subdivision Engineering Office of the Director M ❑ ❑ District Support Services ❑ Traffic Engineering ❑ T t'/1y/- �iI/V�i � O ATTENTION: Date: &U &2 Regard' (Finance Nu I E EPOSIT T P UP MIN/DR: [� A.P.N.: Transmitted as following: Final Parcel Map ❑ Final Map ❑ Check(s) Checkprint(s) / Approved Copy / Original(s) / Certificate Traverse Calculations ❑ Reference Maps E] Plancheck Comments E] Easement re: Covenant re: Agreement re: Comments /Additional Space for Document 5EC OriloN E; N o F P450 PL NtED (1) FPQVF of Pu¢G)#45e of 2-55 AC, OF CSS M ITIGt -TIOp+ cREbI (2 ) "CE0 A Foe,AVE+D 5"e'&I rjtol.o�tutL Sc+Ct/El1 Crash an Check(s) ckprmt "pproved opy /Original(s) Plancheck Comments ❑ S al Calculations ❑ Cost Estimate ❑ Hydrology Study /Map ❑ Soil Report ❑ 3"f8'9a QT7}E'Q W t5�, , ERADxtb CeNfeRrS T° AfP�r Pw+rs. Sketch (if needed): Improvement Plan ❑ Check(s) Checkprint(s) /Approved Copy /Original(s) Plancheck Comments ❑ Structural Calculations ❑ Cost Estimate ❑ Hydrology Study /Map ❑ Cross Sections ❑ As Per... our conversation E] My /your inquiry ❑ Our Review ❑ Our Inquiry �ft' For your..correction� Comment Signature Information [] Uses ❑ Please return 4y�/ ;? Please call: 7� , if necessary Originator: R Nl.Gi� Copies to: 42 V Messenger ❑ Mail ❑ Fascimile ❑ Other I Received by: Date: A Title: Location: ❑ Telephone: 505 South Vulcan Avenue, Encinitas, California 92024 -3633 TEL (619) 633- 2600/FAX (619) 633 -2627 / TDD (619) 633 -2700 954.doc (10- 03 -95) RESOLUTION NO. PC 98-05 A RESOLUTION OF THE CITY OF ENCINITAS PLANNING COMMISSION APPROVING A TENTATIVE PARCEL MAP FOR THE SUBDIVISION OF A 15.72 ACRE PARCEL INTO FOUR SINGLE FAMILY RESIDENTIAL PARCELS AND A REMAINDER PARCEL FOR PROPERTY LOCATED ON THE SOUTH SIDE OF DOUBLE LL RANCH ROAD, WEST OF THE INTERSECTION OF DOUBLE LL RANCH ROAD AND LONE JACK ROAD (APN: 264- 240 -38; Case No. 97 -201 TPM/EIA) WHEREAS, a request for consideration of a Tentative Parcel Map was filed by Zack Abbasi / Pasco Engineering to create four residential lots in excess of two net acres each and a 2.16 net acre Remainder Parcel in accordance with Section 66474 of the State Map Act and Title 24 of the Municipal Code for property located south of Double LL Ranch Road and west of the intersection of Double LL Ranch Road and Lone Jack Road, and legally described as: LOT 6 OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, APRIL 25, 1996. WHEREAS, the Planning Commission conducted a noticed public hearing on the application on January 8, 1998, at which time all those desiring to be heard were heard; and WHEREAS, the Planning Commission considered, without limitation: 1. The January 8, 1998 Agenda Report to the Planning Commission, 2. The General Plan, Zoning Code, State Subdivision Map Act, the Environmental Initial Assessment, and associated Land Use Maps; 3. Oral evidence submitted at the hearing; 4. Written evidence submitted at the hearing; 5. Project plans consisting of two sheets, including: (1) The Replacement Tentative Parcel Map; and (2) Cross - Section Drawings through the Tentative Parcel Map area, all dated received by the City of Encinitas on September 22, 1997. In addition, the following maps were reviewed by the Planning Commission at the hearing: (a) A cd/cto/f.97repons/97- 201 pc1(1 -8.98) Slope Analysis of the Property; and (b) A 10% Slope Encroachment Analysis of the Property; and WHEREAS, the Planning Commission made the following findings pursuant to Chapter 24 (Subdivisions) of the City of Encinitas Municipal Code: (SEE ATTACHMENT "A ") NOW, THEREFORE, BE IT RESOLVED that the Planning Commission of the City of Encinitas hereby approves application No. 97 -201 TPM/ElA subject to the following conditions: (SEE ATTACHMENT "B ") BE IT FURTHER RESOLVED that the Planning Commission, in its independent judgment, finds that a mitigated Negative Declaration is adopted for this project. This project will not individually or cumulatively have an adverse effect on wildlife resources, as defined in Section 711.2 of the Fish and Game Code and, therefore, a Certificate of Fee Exemption shall be made with De Minimis Impact Findings. PASSED AND ADOPTED this 8th day of January, 1998, by the following vote, to wit: AYES: Wells, Jacobson, Lanham, Parton, Bagg NAYS: None ABSENT: None ABSTAIN: None Alice Jacobson, Cl Planning Commiss o , City of Encinitas ATTEST: Sandra L. nolder a {-�t- Secretary NOTE: This action is subject to Chapter 1.04 of the Municipal Code, which specifies time limits for legal challenges, cd/cro/f:97mpon&'97 -201 pc I(1 -8 -98) ATTACHMENT "A" Resolution No. PC 98 -05 Case No. 97 -201 TPM/EIA FINDINGS FOR A TENTATIVE PARCEL MAP STANDARD: Section 66474 of the California Government Code requires that the authorized agency approve an application for a Tentative Map unless, based upon the information presented in the application and during the Public Hearing, the authorized agency makes any of the following findings of fact: a. That the proposed map is not consistent with applicable general and specific plans as specified in Section 65451 of the Subdivision Map Act. Facts: The Tentative Parcel Map proposes four residential lots, each measuring at least two net acres in size, and a Remainder Parcel of 2.16 net acres. The residential lots are configured and designed to conform with the development standards of the Rural Residential Zoning District and will support future development of single family residences. Discussion: The project complies with the density limitations of the General Plan for the Rural Residential land use designation. Conclusion: Therefore, the Planning Commission finds the Tentative Parcel Map is consistent with the City of Encinitas General Plan. b. That the design or improvement of the proposed subdivision is not consistent with applicable general and specific plans. Facts: The Tentative Parcel Map proposes lot sizes which are consistent with the provisions of the Rural Residential (RR) Zoning District. Discussion: All other design requirements for future single family residences can be accommodated by the design of the Tentative Parcel Map. Conclusion: Therefore, the Planning Commission finds that the Tentative Parcel Map's design is consistent with the City's General Plan. C. That the site is not physically suitable for the type of development. Facts: An Environmental Initial Assessment (EIA) has been completed for the project and mitigations have been required to reduce environmental impacts below a level of significance. No evidence has been submitted during the project review process to indicate that the site is not physically suitable for future development with single family residential structures. The residential lots are provided adequate access and the site is physically suited cd/cm/f.97mpons 97 -201 pc 1(1 -8 -98) to provide for four residential lots. The applicant has submitted "will service" letters from the Water, Sewer, School Districts, and Fire Department. Discussion: The project is designed, or has been conditioned, to satisfy development requirements of the Rural Residential Zoning District. The application is proposing four residential parcels and a Remainder Parcel. The Remainder Parcel can not be developed until a future date and additional City review. Conclusion: Therefore, the Planning Commission finds that the site is physically suitable to accommodate the future development of four single family residences and that the subdivision is designed, or has been conditioned, to comply with development standards established by the Rural Residential Zoning District. d. That the site is not physically suitable for the proposed density of development. Facts: The Tentative Parcel Map proposes four residential lots and a Remainder Parcel which comply with the slope adjusted maximum density standard for the Rural Residential Zoning District. Discussion: The project complies with the net acreage, slope adjusted, maximum density standard for the Rural Residential Zoning District. No evidence has been received during the planning review process to indicate that the site is not physically suitable for the proposed density. Conclusion: Therefore, the Planning Commission finds that the Tentative Parcel Map conforms to the density requirements for the Rural Residential Zoning District. e. That the design of the subdivision or the proposed improvements are likely to cause substantial environmental damage or substantially or avoidably injure fish or wildlife or their habitat. Facts: An Environmental Initial Assessment (EIA) has been conducted by the City's Environmental Consultant for the project, Mooney & Associates. Discussion: It has been determined that all project impacts have been adequately analyzed in the Environmental Initial Assessment (EIA) and environmental impacts have been avoided or mitigated by the project's design, conditions of approval, or the environmental mitigations required by the Negative Declaration. Approval of the subject application request would have no impact on the MHCP and NCCP programs since the site was reviewed by the Wildlife Agencies and it was determined that the Diegan Coastal sage scrub on the property is of limited value to wildlife enhancement due to the fragmentation and isolation of the on -site habitat from other larger areas of habitat. The applicant ha- agreed to the off -site purchase of mitigation credits within an established mitigation lane. conservation bank at a 1:1 ratio prior to grading permit approval for the parcels created by the Tentative Parcel Map. Said acquisition shall be approved by the City in consultation cd/cro/f 97repons/97 -201 pc 1(1 -8 -98) with Wildlife Agency staff prior to its purchase and the impacted area will be deducted from the City's 5% Interim Take Allowance. Conclusion: Therefore, the Planning Commission finds that the design of the subdivision and proposed improvements will not cause substantial environmental damage or substantially and avoidably injure fish or wildlife or their habitat. f That the design of the subdivision or the type of improvements is likely to cause serious public health problems. Facts: The applicant has submitted "will service" letters to indicate that the Water, Sewer, Fire and School agencies can provide adequate service and utilities to the project site. Discussion: No evidence has been submitted to indicate that a serious public health problem would occur should a Final Parcel Map, in accordance with the approved Tentative Parcel Map, be recorded and the proposed residences be constructed. Conclusion: Therefore, the Planning Commission finds that the design of the subdivision and the future residences on the site can be adequately serviced with necessary utilities and the project will not cause any serious public health problems. g. That the design of the subdivision or the type of improvements will conflict with easements, acquired by the public at large, for access through or use of, property within the proposed subdivision. In this connection, the authorized agency may approve a map if it finds that alternate easements, for access or for use, will be provided, and that these will be substantially equivalent to ones previously acquired by the public. This subsection shall apply only to easements of record or to easements established by judgment of a court of competent jurisdiction and no authority is hereby granted to a legislative body to determine that the public at large has acquired easements through or use of property within the proposed subdivision. Facts: The Tentative Parcel Map indicates that adequate access to each of the residential lots can be provided in conformance with City standards. All other known easements for utilities or access are indicated on the Tentative Parcel Map and will remain for access to public utilities. Discussion: The design of the Tentative Parcel Map will not conflict with any easements for utilities or roadways. All access easements and utilities will be shown on the Final Parcel Map in accordance with City standards and the servicing utility's requirements. Conclusion: Therefore, the Planning Commission finds that the design of the subdivision and future improvements will not conflict with any public easements nor hinder access to, or the use of, property within the proposed subdivision. cNcro/f:97mporLv97 -201 pc 1( 1 -8-99) ATTACHMENT °B" Resolution No. PC 98 -05 Project No.: 97 -201 TPM/EIA Applicant: Zack Abbasi Location: South of Double LL Ranch Road, West of Lone Jack Road SCI SPECIFIC CONDITIONS: SC4 Approval of the Tentative Parcel Map and all associated permits will expire on January 8, 2000 at 5:00 pm, two years after the approval of this project, unless the conditions have been met or an extension of time has been approved pursuant to the Municipal Code. SC5 This project is conditionally approved as set forth on the application and project plans dated received by the City on September 22, 1997, consisting of two sheets including: (1) The Replacement Tentative Parcel Map; and (2) Cross - Section Drawings through the Tentative Parcel Map area. In addition, the following maps were reviewed and approved by the Planning Commission at the hearing: (a) A Slope Analysis of the Property; and (b) A 10% Slope Encroachment Analysis of the Property. Said plans shall not be altered without express authorization by the Community Development Department. SC6 To facilitate the acquisition of an east -to -west recreational trail link (if needed to augment potential trail easements on Tentative Map 97 -219), the City is authorized to determine if an eight foot trail easement is necessary over Parcels 1 and 4 and the Remainder Parcel prior to Final Parcel Map recordation. If determined necessary by the Community Development and Engineering Services Departments, the trail easement shall be located within the IOD area for Double LL Ranch Road. 1 ; 1 • 1 • CONTACT THE COMMUNITY DEVELOPMENT DEPARTMENT REGARDING COMPLIANCE WITH THE FOLLOWING CONDITION(S): G2 This approval may be appealed to the City Council within 10 calendar days from the date of this approval in accordance with Chapter 1.12 of the Municipal Code. G4 Prior to building permit issuance, the applicant shall cause a covenant regarding real property to be recorded. Said covenant shall set forth the terms and conditions of this grant cd/cro/f.97repons/97 -201 pc1(1 -8 -98) of approval and shall be of a form and content satisfactory to the Community Development Director. i G5 Approval of this request shall not waive compliance with any sections of the Municipal Code and all other applicable City regulations in effect at the time of Building Permit issuance unless specifically waived herein. f/ G13 The applicant shall pay development fees at the established rate. Such fees may include, but not be limited to: Permit and Plan Checking Fees, Water and Sewer Service Fees, School Fees, Traffic Mitigation Fees, Flood Control Mitigation Fees, Park Mitigation Fees, and Fire Mitigation/Cost Recovery Fees. Arrangements to pay these fees shall be made prior to Final Parcel Map approval to the satisfaction of the Community Development and Engineering Services Departments. The applicant is advised to contact the Community Development Department regarding Park Mitigation Fees, the Engineering Services CO''' Department regarding Flood Control and Traffic Fees, applicable School District(s) regarding School Fees, the Fire Department regarding Fire Mitigation/Cost Recovery Fees, and the applicable Utility Departments or Districts regarding Water and/or Sewer Fees. G ✓ G14 A Dlan shall be submitted for approval by the Communitv Development Department, the Engineering Services Department, and the Fire Department regarding the security treatment of the site during the construction phase, the on- and off -site circulation and parking of construction workers' vehicles, and any heavy equipment needed for the construction of the project. M2 All project grading shall conform with the approved Tentative Parcel Map. In cases where no grading is proposed at the time of the Tentative Parcel Map, or in cases where the grading plan later submitted is not consistent with the approved Tentative Parcel Map, the applicant shall be required to obtain a design review permit for grading prior to issuance of grading permits. p' d M4 The property owner /developer shall obtain design review permits through the City for homes to be constructed on the lots resulting from the approved map, as well as all related site improvements. If the property owner /developer elects to develop the lots resulting from the approved final map as custom homesites, the design review permit requirement may be waived by the Community Development Department pursuant to Section 23.08.030 (7) of the Municipal Code. The property owner /developer is advised to contact the Community Development Department at such time as development of the subject property is planned to determine whether a design review permit will be required. A standard covenant specifying this condition shall be recorded in the Office of the County Recorder to give constructive / notice to future purchasers of the site. M6 Street names shall be approved by the City prior to the recordation of the final map, and R street addresses shall be provided by the Community Development Department prior to the issuance of building permits. cd/cro/f 97reportst97 -201 pc I( 1 -8-98) FIW1 Approval of the 4(d) permit in conjunction with this application does not constitute C �" authorization for the take of habitat at this time. The City has a "first -come, first- served" policy for interim taking of habitat lands through the 4(d) permitting process, such that the take will be authorized only at such time that a grading plan is submitted and approved by the City as being within the cumulative 5% take limitation for habitat lands. CONTACT THE ENCINITAS FIRE DEPARTMENT REGARDING COMPLIANCE WITH THE FOLLOWING CONDITIONS: F2 ACCESS ROADWAY DIMENSIONS: Fire apparatus access roadways shall have an unobstructed paved width of not less than 24 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. EXCEPTION: Access to one (1) single family residence shall not be less than 16 feet of paved width. F5 GRADE: The gradient for a fire apparatus roadway shall not exceed 20.0 %. Grades exceeding 15.0% (incline or decline) shall not be permitted without mitigation. Minimal mitigation shall be the installation of automatic fire sprinkler systems for structures accessed by such a roadway. F8 COMBUSTIBLE MATERIALS: Prior to the delivery of combustible materials on the project site, water and sewer systems shall satisfactorily pass all required tests and be connected to the public water and sewer systems. In addition, the first lift of asphalt paving shall be in place to provide a permanent all- weather surface for emergency vehicles. Said access shall be maintained to the satisfaction of the Fire Department. F9 POSTING OF ROADWAYS: Emergency access roadways when required shall be properly identified as per Fire Department standards. F10 OBSTRUCTIONS (ACCESS ROADWAYS): All traffic lanes shall be a minimum of 24 feet in width during construction and shall be maintained clear and free of obstructions during construction in accordance with the Uniform Fire Code. F11 FIRE HYDRANTS & FIRE FLOWS: The applicant shall provide fire hydrants of a type, number, and location satisfactory to the Encinitas Fire Department. A letter from the water agency serving the area shall be provided that states the required fire flow is available. Fire hydrants shall be of a bronze type. A two -sided blue reflective road marker shall be installed on the road surface to indicate the location of the fire hydrant for approaching fire apparatus. F12 FUEL MODIFICATION ZONES: The applicant shall provide and maintain fire /fuel breaks to the satisfaction of the Encinitas Fire Department. c&cro/f.97mpons/97 -201 pc [(1 -8-98) F13 ADDRESS NUMBERS: Address numbers shall be placed in a location that will allow them to be clearly visible from the street fronting the structure. The height of the address numbers shall conform to Fire Department Standards. I F15A AUTOMATIC FIRE SPRINKLER SYSTEM - SINGLE- FAMILY DWELLINGS AND DUPLEXES: Structures shall be protected by an automatic fire sprinkler system installed to the satisfaction of the Fire Department. Plans for the automatic fire sprinkler system shall be approved by the Fire Department prior to issuance of building permits. E1 ENGINEERING CONDITIONS: CONTACT THE ENGINEERING SERVICES DEPARTMENT REGARDING COMPLIANCE WITH THE FOLLOWING CONDITION(S): E2 All City Codes, regulations, and policies in effect at the time of building/grading permit issuance shall apply. ✓ EG1 Grading Conditions ✓ EG2 No grading permits shall be issued for this subdivision prior to recordation of the final map. EG3 The developer shall obtain a grading permit prior to the commencement of any clearing or grading of the site. EG4 The grading for this project is defined in Chapter 23.24 of the Encinitas Municipal Code. Grading shall be performed under the observation of a civil engineer whose responsibility it shall be to coordinate site inspection and testing to ensure compliance of the work with the approved grading plan, submit required reports to the Engineering Services Director and verify compliance with Chapter 23.24 of the Encinitas Municipal Code. EG7 All newly created slopes within this project shall be no steeper than 2:1. EG8 A soiWgeological/hydraulic report (as applicable) shall be prepared by a qualified engineer ' licensed by the State of California to perform such work. The report shall be approved prior to final map approval. ED1 Drainage Conditions .Y ED2 The developer shall exercise special care during the construction phase of this project to S,q5, prevent any offsite siltation. The developer shall provide erosion control measures and shall construct temporary desiltation/detention basins of type, size and location as approved by the Engineering Services Director. The basins and erosion control measures shall be shown and specified on the grading plan and shall be constructed to the satisfaction of the Engineering Services Director prior to the start of any other grading operations. Prior to the removal of any basins or facilities so constructed the area served shall be protected by cd1cro/r97mpons/97.201 pc I(1 -8 -98) additional drainage facilities, slope erosion control measures and other methods required or approved by the Engineering Services Director. The developer shall maintain the temporary basins and erosion control measures for a period of time satisfactory to the Engineering Services Director and shall guarantee their maintenance and satisfactory performance through cash deposit and bonding in amounts and types suitable to the Engineering Services Director. �/ ED7 Concentrated flows across driveways and/or sidewalks shall not be permitted. E�SI Street Conditions oa v /ES2 A registered Civil Engineer or a licensed land surveyor shall provide a signed statement F" that: "The existing private roads of access to the project are within the easements for the / benefit of the land division." S�f " ES4 Reciprocal access and/or maintenance agreements shall be provided ensuring access to all r"W", parcels over private roads, drives or parking areas and maintenance thereof to the / satisfaction of the Engineering Services Director. 41 ES8 The design of all private streets and drainage systems shall be approved by the Engineering C��- Services Director prior to approval of the Final Parcel Map for this project. The structural Syla section of all private streets shall conform to City of Encinitas Standards based on R -value tests. The standard improvement plan check deposit is required. The planned 6 inch AC pf� Dike shall be installed along the frontage of Double LL Ranch Road of this project. ES10 Improvements constructed within the present or future public right -of -way shall be d� NE considered temporary. The applicant shall enter into an encroachment removal covenant agreeing to remove those improvements at the direction of the City. EU1 Utilities / EU2 The developer shall comply with all the rules, regulations and design requirements of the respective utility agencies regarding services to the project. EU3 The developer shall be responsible for coordination with S.D.G. & E., Pacific Telephone, and other applicable authorities. EU4 All proposed utilities within the project shall be installed underground including existing utilities unless exempt by the Municipal Code. EU5 The developer shall be responsible for the relocation and undergrounding of existing public utilities, as required. fW �% 6 If private sewer will serve this development, then a maintenance agreement must be executed before recordation of the Final Map. Wcrc/f.97repens/97 -201 pc1(1 -8 -98) EMI Map / EM3 This project is approved specifically as 1 (single) phase. t �EM4 This subdivision contains a remainder parcel. No building permit shall be issued for the 641"" remainder parcel until it is reviewed and approved pursuant to the provisions of Title 24 of the Encinitas Municipal Code. This note shall be placed on the final map. ENVIRONMENTAL. MITIGATIONS: C•Q• A biological open space easement shall be recorded over 1.87 acres of Parcel 3 that encompass the entire scrub oak woodland area shown on the biological resource map included in the 1993 Mooney & Associates Biological Survey and Report for the Lloyd property. The project applicant/developer shall purchase 2.55 acres of Diegan coastal sage scrub (CSS) from the Manchester Avenue Conservation Bank or other mitigation bank that contains coastal sage scrub and is approved by the City of Encinitas, U.S. Fish & Wildlife Service, and the California Department of Fish & Game. Any CSS vegetation which is impacted by the project shall only be removed prior or after the gnatcatcher breeding season (February 15 through August 30). Fuel Modification Zones shall be delineated on the Final Parcel Map and, if the zones impact any additional CSS vegetation, a like amount of CSS credits shall be purchased in addition to the 2.55 acres. A focused spring survey shall be conducted for San Diego goldenstar, Palmer's grapplinghook, thread- leaved brodiaea, and San Diego thommint prior to the issuance of a Grading Permit or the recordation of the Final Map. cd/cro/f.97mpons/97 -201 pc I(I -8 -98) PROJECT REVIEAV REQUEST CITY OF ENCINITAS Community Development Department 505 South Vulcan Avenue Encinitas, CA 92023 -3633 CAB AREA: OZ! 119!0*41Aj SUBMITTAL DATE: 2-7 AuG q-7 CASE NUMBER:7— Z 01 TPN1 /4!FiA FINANCE NUMBER: APPLICANT: Z"C-l" 486A61 / 04%frie- )%Sco 82► zTP ADDRESS: Lo% 6 of Dou a4E LL rOmew APN: :2 6-f — 2+0 - 3 8 us DESCRIPTION: TPM a EJA 'To 6tASDIVIDE A 15. 72 4c& PWf l i.JTD 4 gesur j'rlA Z A-Xc FCS 4-ZAc n,er AP40 A 9eMA -"a0ex ENVIRONMENTAL STATUS: F /IA -ro BE M669,60 0V RSS&-- - TO [ ] Sandy Holder, CD Director [ ] Bill Weedman, City Planner • [ ] Gary Barberio, Senior Planner [ ] Will Foss, Building Division Supervisor • [ ] Cindy Adams, Code Enforcement Coordinator [ ] David Moore, Dep. Fire Marshay Mike Castanada, Fire Prevention Officer [ ] Hans Jensen, Sr. Civil Engineer • [ ] Rob Blough Assoc. Traffic Engineer [ ] Victor Graves, Planner, • San Dieguito Water District [] Jessie Tench, Superintendent Parks & Beaches [ ] Bill Harms, Crime Prevention Specialist Sheriff's Office (Encinitas) ACTION REQUESTED: Date Transmitted: 8-21 -Q-7 Return by (Date): 9 -1c -q-7 RETURN TO CD DEPARTMENT CONTACTPLANNER Craig Olson Associate Planner Ext.2713 [ ] INITIAL REVIEW [ ] ENTER APPLICABLE CONDITIONS /COMMENTS IN HTE PLANNING /ZONING MODULE [ ] RE- REVIEW. NOTE CHANGES �yc� Re'�?_0 Pt^*s wj 14PITFrj c40fAl%^g -j6 fS ENTERED BY: P. e • ,J_awp' � DATE: 10-L —9 T ADDITIONAL COMMENTS TO PLANNER: Igo- 4 �kd'e_ a Cap , (CONTINUE COMMENTS ON BACK IF NECESSARY) LK/hz/MS28- 2701.doc (11- 14 -94) Project No. 97 -201 TPM /EIA Applicant: Abbasi October 6, 1997 Page 1 CITY OF ENCINITAS Project No. 97 -201 TPM /EIA Applicant: Abbasi APPLICANT SHALL CONTACT THE CITY ENGINEERING DEPARTMENT REGARDING COMPLIANCE WITH THE FOLLOWING CONDITIONS: All City Codes, regulations, and policies in effect at the time of tentative map approval shall apply. Grading Conditions 1. No grading permits shall be issued for this subdivision prior to recordation of the final map. 2. The developer shall obtain a grading permit prior to the commencement of any clearing or grading of the site. 3. The grading for this project is defined in Chapter 23.24 of the Encinitas Municipal Code. Grading shall be performed under the observation of a civil engineer whose responsibility it shall be to coordinate site inspection and testing to ensure compliance of the work with the approved grading plan, submit required reports to the City Engineer and verify compliance with Chapter 23.24 of the Encinitas Municipal Code. 4. All newly created slopes within this project shall be no steeper than 2:1. 5. A soils /geological /hydraulic report (as applicable) shall be prepared by a qualified engineer licensed by the State of California to perform such work: a. Prior to final map approval; or b. Prior to building permit issuance; or C. At first submittal of a grading plan. Drainage Conditions 6. The developer shall exercise special care during the construction phase of this project to prevent any offsite Project No. 97 -201 TPM /EIA Applicant: Abbasi October 6, 1997 Page 2 siltation. The developer shall provide erosion control measures and shall construct temporary desiltation /detention basins of type, size and location as approved by the City Engineer. The basins and erosion control measures shall be shown and specified on the grading plan and shall be constructed to the satisfaction of the City Engineer prior to the start of any other grading operations. Prior to the removal of any basins or facilities so constructed the area served shall be protected by additional drainage facilities, slope erosion control measures and other methods required or approved by the City Engineer. The developer shall maintain the temporary basins and erosion control measures for a period of time satisfactory to the City Engineer and shall guarantee their maintenance and satisfactory performance through cash deposit and bonding in amounts and types suitable to the City Engineer. 7. Concentrated flows across driveways and /or sidewalks shall not be permitted. Street Conditions 8. A registered Civil Engineer or a licensed land surveyor shall provide a signed statement that: "The existing private roads of access to the project are within the easements for the benefit of the land division ". 9. Reciprocal access and maintenance and /or agreements shall be provided ensuring access to all parcels over private roads, drives or parking areas and maintenance thereof to the satisfaction of the City Engineer. 10. The design of all private streets and drainage systems shall be approved by the City Engineer prior to approval of the final map /issuance of any grading or building permit for this project. The structural section of all private streets shall conform to City of Encinitas Standards based on R -value tests. The standard improvement plan check deposit is required. The planned 6 inch AC Dike shall be installed along the frontage of LL Ranch Road of this project. 11. Improvements constructed within the present or future public right -of -way shall be considered temporary. Applicant shall enter into an encroachment removal covenant agreeing to remove those improvements at the direction of the City. 2 Project No. 97 -201 TPM /EIA Applicant: Abbasi October 6, 1997 Page 3 Utilities 12. The developer shall comply with all the rules, regulations and design requirements of the respective utility agencies regarding services to the project. 13. The developer shall be responsible for coordination with S.D.G. & E., Pacific Telephone, and Cable TV authorities. 14. All proposed utilities within the project shall be installed underground including existing utilities unless exempt by the Municipal Code. 15. The developer shall be responsible for the relocation and undergrounding of existing public utilities, as required. map 16. This project will be approved specifically as 1 (single) phase. 17. This subdivision contains a remainder parcel. No building permit shall be issued for the remainder parcel until it is further subdivided or a Certificate of Compliance is issued by the City of Encinitas pursuant to the provisions of Title 24 of the Encinitas Municipal Code. This note shall be placed on the final map. 18. The developer shall be responsible for the payment of Flood Control Impact Fees, Park Fees, and Traffic Impact Fees before the approval of the grading plan, or enter into a security agreement for the payment of such fees: For new residential dwelling unit(s), the applicant shall pay development fees at the established rate. Such fees may include, but not be limited to: Permit and Plan Checking Fees, School Fees, Water and Sewer Service Fees, Traffic Fees, Drainage Fees, and Park Fees. As required, arrangements to pay these fees shall be made: 1. Prior to building permit issuance. 2. For Traffic Fees, prior to issuance of occupancy certificate. 3 CITY OF ENCINITAS ADMINISTRATIVE APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT 505 South Vulcan Avenue Encinitas, California 92024 (619) 633 -2722 Application No. 9-1 -ZD Date of Application: 64 Z Community Area oZt t/csW Project Name: ABBA4T TFN A TV . PAR . . Project Address: Double LL Ranch Road APN: 264 -240 Between Wiegand Street And Copper Crest (Street) (Street) APPLICANT Name: Abbasi, Zahoor Phone: (760-) 738 -7500 (Last, First, Middle Initial or Firm Name) Address: P.0. Box 46 885 City Escondido State CA Zip 92046 -2885 OWNER(S) Name: Same as Applicant Phone: (Last, First, Middle Initial or Firm Name) Address: City C01dddi:\baPtXCOAPP.00C (9/5195) State Zip DEPARTMENT USE ONLY APPLICATION TYPE (check all that apply) Finance # Code Amount ❑ Administrative Design Review ............................ ............................... ❑ Certificate of Compliance .................................... ............................... ❑ Coastal Development Permit .............................. ............................... Exempt _ Regular permit Appeal Zone? Y _ N Cat. excluded _ CCC permit R1 Environmental Submittal (EIA/Neg. Dec /EIR 621 2 EN f 'D 3 3 S(7So ❑ Extension Request .............................................. ............................... rLot Line Adjustment ............................................ ............................... ❑ Minor Use Permit ................................................ ............................... ❑ Minor Variance (reduction of setback by 20% or less) ...................... ❑ Sign ..................................................................... ............................... ❑ Sign Program ...................................................... ............................... ® Tentative Parcel Ma d f n`A�N ° .� ........................ y-Z P 7-OW El Waiver of Side Yard Setback (Sec. 30.16.010B10) .......................... ❑ Waiver of Standard Height Regulations (Section 30.16.010B) ......... Total Paid: Please complete the following: Project Name: ABBA4T TFN A TV . PAR . . Project Address: Double LL Ranch Road APN: 264 -240 Between Wiegand Street And Copper Crest (Street) (Street) APPLICANT Name: Abbasi, Zahoor Phone: (760-) 738 -7500 (Last, First, Middle Initial or Firm Name) Address: P.0. Box 46 885 City Escondido State CA Zip 92046 -2885 OWNER(S) Name: Same as Applicant Phone: (Last, First, Middle Initial or Firm Name) Address: City C01dddi:\baPtXCOAPP.00C (9/5195) State Zip ENGINEER /ARCHITECT Name:PASCO ENGINEERING, INC. (Last, First, Middle Initial or Firm Name) Address: 535 No. Highway 101, Suite A City Solana Beach State CA Zip 92075 "PLEASE ATTACH A DESCRIPTION OF THE PROPOSED USE / PROJECT TO THIS APPLICATION. Have you had a pre - application meeting? II Yes ❑ No If yes, name of planner. Olson /Weedman Has construction or use of the property for which this permit is requested started? ❑ Yes Q No if yes, explain: I am able and intend to proceed with actual construction work and/or division of land in accordance with plans submitted herein within ASAP months after approval. I acknowledge that an application for a tentative map or tentative parcel map is not deemed received pursuant to Government Code 65920 et seq. until environmental review is complete. All other application types are not deemed received until responses from interested agencies are received by the City. I understand that if the project or any alternatives are located on a site which is included on any of the Hazardous Waste and Substances lists compiled by the Secretary for Environmental Protection pursuant to Section 65962.5 of the Government Code, then a Hazardous Waste and Substances Statement must be submitted with this application. (Information that must be included in this statement can be obtained from the Community Development Department.) I further understand that all fees and deposits submitted with this application will be refunded only as provided for by the ordinances and regulations in effect at the time of the request. 3. nature, er or Authorized Agent (Attach lettg o.,fq authorization) //.I�— ��"""7' ccrcr4Gl�I ✓�wClJir lAl Print or Type Signators Name aG � 7 Date I CITY OF ENCINITAS PROJECT SUMMARY PROPOSED USE Single Family Residence Parcel Map CASES g7-Za/ OWNER/APPLICANT Zahoor Abbasi ENGINEER Pasco Engineering, Inc. GENERAL PLANDESIGNATION Rural Residential ZONING REGULATIONO. 25 -0.50 DU /A&ES 16 AC NO. OF LOTS 4 NO. OF DWELLING UNITS N/A -} PC,E^ AjouD ex- CHECK SCHOOL DISTRICT(S): _ CARDIFF ELEMENTARY X ENCINITAS UNION ELEMENTARY X SAN DIEGUITO UNION HIGH SEWERDISTRICT Cardiff Sanitation WATER DISTRICT 01 i vPnhai n ASSESSOR BOOK 264 PAGE 240 PARCEL 03 DATE RECD HEARING DATE NORTH SCALE - 1'= L( D D CITY OF ENCINITAS DISCLOSURE STATEMENT APPLICANTS STATEMENT OF DISCLOSURE OF CERTAIN OWNERSHIP INTERESTS ON ALL APPLICATIONS WHICH WILL REQUIRE DISCRETIONARY ACTION ON THE PART OF THE CITY COUNCIL, PLANNING COMMISSION, AND ALL OTHER OFFICIAL BODIES. The following information must be disclosed: 1. List the names of all persons having a financial interest in the application. ?�tu��PafEwi ' ✓(l41Vt1/N4 CoalS�rl�ilfNTS Z�t1TE�Nl4T /ovl9L iNc List the names of all persons having any Ownership interest in the property involved. J 2. If any person identified pursuant to (1) above is a corporation or partnership, list the names of all individuals owning more than 10% of the shares in the corporation or owning any partnership interest in the partnership. .7 u>g�,� �,� � ��� ohs: T-eE sy� 3. If any person identified pursuant to (1) above is a non -profit organization or a trust, list the names of any person serving as director of the non -profit organization as trustee or beneficiary or trustor of the trust 4. Have you had more that $250 worth of business transacted with any member of City staff, Boards, Commissions, Committees, and Council within the past twelve months? ❑ Yes ZEI_No If yes, please indicate person(s). PERSON is defined as: "Any individual, firm, copartnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, this and any other county, city and county, city, municipality, district or other political subdivision, or any group or combination acting as a unit." (NOTE: Attach additional pages as necessary.) Signature of Applicant D CD /ddd1:1BAPTOISCLOS E. DOC(6 /4/96) Please Print or Type Signator's Name Applicants Name Mailing Address COMMUNITY DEVELOPMENT DEPARTMENT CITY OF ENCINITAS 505 South Vulcan Avenue Encinitas, California 92024 (619) 633 -2722 EVIDENCE OF LEGAL PARCEL ZAHOOR ABBASI P.O. Box 462885 City Escondido Telephone(760_ 738 -7500 State CA Zip92046 -2885 You are required to supply documentation that this property constitutes a legal parcel before the City can accept for filing any discretionary permits. This form and associated evidence will be reviewed by the Community Development Department upon submittal of your application. A request for a Certificate of Compliance must be filed concurrently with or in, advance of this application if the evidence presented is insufficient to determine this parcel as being a legal lot or determination will require substantial time to research. If determined that the property is not a legal lot, no permit or other approval may be granted until corrective action has been completed. Fees and deposits submitted with this application will be refunded only as provided for by the ordinances and regulations in effect at the time of the request. Book 264 Signature of Applicant cdlddcA:\BAPTTLEGPAR C.DOC(9115195) Page 240 Parcel 03 /Nc 08/22 '99 12:08 ID:FIRST AMERICAN TITLE FAX:619 -231 -4694 PHbE= 1 •a" ITV,ew Dot 1► 1/ 141921+1 �. RECORDING REQUESTED 13Y 1 25— APR -1997 03 ■ 15 PM cxICA00 TITLE COMPA14Y pt n a A AND WHEN RECORDED MAIL TO OFFICIAL RECO1tD5 O SAR DIEGO CUTY RECORDER'S OFFICE Dewlopltwnt Planning GREGORY SA7.00 OUHFE RECORDER Consultants International, Inc. 135 RFr 7.00 FEES, 5]5.50 AF: 5.00 OC V.O. BOX 46298S ��- IFI 1.00 E6COM1IDO, CA 92046 TAX" 522.50 L -� tscrOl NO. '1871014 -ae )_64-- L.4A'3� iM4E Aaoxr ir41 u+r icn Rc00apir.e Vsr GRANT DEED aaaaea rar<e1 pni 264 - 2140 0 -30 THG UNDElISiGNPII ORANTt1R(S) DBCIAPAS) DOCUMeNTARY TRANSFBRTAXIS $522.50 ❑ unlaoaµn.Wduts 0 Ckyoy ENCINITAS ® mmpattd on 1M fuN •+lue or tae iau,est or propcny tva,gtd, w u ❑ romputsd attlw Ntt value ks4 tbe.elue o[1ita4 or anc>,ta6raaar rcmandnt at krocduk,sM FOR A VALUABLE CONSIDERATION , receipt of which i1 heteE,y acknowledged tAk1t1 YP5] MAN Ct1RISTOpHER S. LLOYD, A MARRIED MAN AND Gk13tiOkY CLEM, A hereby GRANT(S) to DEVfiLOPMENT PLANNING CONSULTANTS INTERNATIONAL, INC., A CALTMIRNIA CORPORATION the following detcritmt real property in the , State d California: Countyuf RAW DIFOO PARCEL A: Lot 6'Of City of Encinitas Tract 93 -029, in the City of Encinitas, County of San Diego, State of California, according to Hap thereof No. 13320, filed in the Office of the County Recorder of San Diego County-on May 10, 1996 as more fully deatribed in Exhibit "A" attachad hereto and made a part hereof... Dated January 29, 1997 STATEOF CALIFORN and . —) Ss . besore me, penlonelly knOwnytO m. W proved w nle'on the bads of M%91a widens) b be the pww(c) whose narna(a) It/an 1ubWibed to 1W M"n Inam,mant aid aolrm+.ladged to"sot M /she /Ihay executed 1he eema in Ms/hey"r suthalsed capaolty 9t), and Vial by Ns/fMtt" peneksoo) on the Iroeunant am perwnh), or tM eMd ty upon banes of whloh 1M penon(e) &1116, e.earlad the InslNment. nm .i0nvap� Orde . 1. l)ORtiN M. ysnFR C01AAl• WGt957 F �' Notory PWae— Coelonvo t slJt DIEGO OOUNry MY Comm. Expka Just. 1099 - °nf Atnericau TFfle •a" ITV,ew C0. 1, pt n a qxe ne " Now" am On a,Nr 3541 N, MAIL AS OIRECTED ADOVE oy, cut. a Zip 0822 '97 12:09 ID:FIRST -' ERICAN TITLE FAX:619- 231-46,% PcwE 3 Order No: 7336034 U52 • —. DESCRIPTION • 137 TARGET. It: LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIRGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICR OF THE COUNTY "CORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B: AN FASEMFNT AND RIGHT OF MAY FOR ROAD AND UTILITY PURPOSES, 32.00 FRR1' IN WIDTH, TOGETHER WITH TIFF RIGHT TO INSTALL AND MAINTAIN UTILITIES AND IO IN.S':ALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSXIP ON 13 SOVL'R, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT TIIRREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF 1HE SUBDIVISION OF RANCHO DE LAS ENCINITAS. IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE. OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1896, DESCRIBED AS FOLLOWS: BEGINNING A1' THE SOUTRWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FELT; THENCE NORTH 2'25'09• WEST 475.03 FEET; THENCE. NORTH 2625'19' WEST TO '111E SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATP.A DISTRICT, RECORDED JULY 2S, 1977 AS FILU 00. 77-266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67 °43'39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL. ANGLE OF 01.24'26' A DISTANCE OF 14.00 FEET TO A POINT ON TIM CENTER LINE OF SAID ROAD SURVEY SS4; SAID POINT BRING THE TRUE POINT OF BEGINNING; THF210E SOUTH 69008'00' WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 °07'07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 TOOT PIPELINE BASEMENT GRANTED TO OLIVENHATN MUNICIPAL WATER DISTRICT, A RADIAL, LINE OF WHICH BEARS NORTH 01 °15'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF TNK SAID PROPERTY AS DESCRIBED IN EXHIBI.1' A, SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRTCT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON - TANGENT 1016.00 POOT RADIUS CURVE CONCAVE NORTHERLY' RADIAL LINE OF WHICH BEARS NORTH 05.01'36" EAST; THSHCH EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25.53'28' A DISTANCE OF 459.16 FEET; THENCE TANOKNT TO SAID CURVE NORTH 69.08'08' EAST. 665.43 FEET TO THE CENTER LIWR OP SAID COUNTY ROAD SURVEY NO. SS4 (LONE JACK ROAD) BEING A POINT ON THE ARC OF SAID NON- TANGENT 570.00 POOT RADIUS CURVE CONCAVE SOUTHWUTLIRLY, A RADIAL LINE OF WHICH BEARS NORTH 72021'11" RAST; THENCE NORTHERLY ALONG SAID CURVE THROWN A CENTRAL ANGLE OF 03 013'05" A DISTANCE. OF 32.01 FRET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. 1 Order: TOF: SM SD 1997 - 192111 Page: 3 of 3 08•x22 '97 12:08 A ID:FIRS- `'ERICAN TITLE AC ; -fiXIM ZOAll State ot_ rtl � �nirx.� l County of J} On Obl 16,199-1 belore me, - o NAYR not 0P p1tICER• ED.'JaNa NDTAA'r aVKK' rsonafl appeared rr Pe Y apps 1 tea. --— *ersonalh known to me - OR Jeanine A. ReSkas U tgana. Ieea7Ee acrauud raurowa +� lnl DIdDDDIa11'r ���yaal yyp.laa7 � ❑ proved to me on the basis of satisfactory evidence to be the persoW whose name�Jare subscribed tot within Instrument and ac- knowledged to me Y executed the same in (Vy:;! jr authorized capacltyTbesi, and-that b fiDO"FAMir slynaturo4 on the instrument the petsorf. or the entity upon bohalf of which the persorN acted. executed the instrument. T HIS CERTIFICATE MUST Be ATTACHED TO THE DOCUMENT DESCRIBED AT RIGHT: Th"o 0, d= IgJWW Pion b IIa NeVaad by law, a DDJd Pia V&Afi" rawaaar nl of M Min. WITNESS my hand arxf officlal seal. PAGE 136 Na. slat e0000i OPTIONAL SECTION r CAPACITY CLAIMED BY SIGNER TDagn avaAa do" aw raryi+v M Naar, w rot In ea "a Dawn. dale 64 ^•a7 PrD.a a1.aUWa w PaaD^a raM'V PD VW ddwmera. 1NDtVIDUAL C] CORPORATE OFFICSRLS) Trt 4&1 0 PARTNER(S) 0 LIMITED 0 GENERAL O ATTORNEY-IN FACT 0 TRUSTEES) GWRDLkWCONSERVATOR 0 cr4pt: SIGNER IS REPRESENTING: I" or ""ISO 4) w eNmnEn .x6` OPTIONAL SECTION TITLE OR TYPE OF DOCUMENT .. — ^ --_ NUMBER Or PAGES _. DATE OF DOCUMENT SIDNER(S) OTHEn THAN NAMED 01"3 NATgNAI NOTARY ASSOUAt" • Ma � A—. P O. ea 71" - Carcpa Pat CA 917D471 a: Order TOP SM SO 1997 - 192111 Page- 2 of 3 1L 1V NET ACREAGE CALCULATIONS TPM GROSS ACRES 13.27 LESS: Dedication Double LL Ranch 0.31 + / -Ac. Road Proposed _1oTNT DRIVE WAY .21 + / -Ac. Private Streets .23 + /_Ac, Significant Wetlands -0- Ac. Utility Utility Easements -0- + / -Ac. NET ACRES 12.52 SLOPE DENSITY RANGE CALCULATION A MAXIMUM RANGE: SLOPE ACRES DENSITY DWELLING UNITS 0 -25% 7.21 X0_5 D.U. = 3.60 25-40% 4.01 +2 x 0.5 D_U_ = 1.00 40%+ 1.36 - none Total 4.60 PYA B. MID - RANGE: / SLOPE ACRES DENSITY DWELLING UNITS 0-25% x - 25-40% 2 x = 40%+ - none Total D.U.'s PT /hz /389.doc (01- 03 -95) 7 NET ACREAGE CALCULATIONS REMAINDER GROSS ACRES LESS: Dedication Double LL Ranch Road Proposed Rd. Private Streets Significant Wetlands Utility Easements NET ACRES SLOPE DENSITY RANGE CALCULATION A. MAXIMUM RANGE: SLOPE ACRES DENSITY 0-25% 1.9 5 x .5 D.U. _ 25 -40% .17 +2 x .5 D.U.= 40%+ .03 _ f0ir 8. MID - RANGE: SLOPE ACRES 0-25% 25-40% 40%+ PT /hz /389.doc (01- 03 -95) Total DENSITY x = =2 x - Total 7 PE 718 2.45 GR 0.22 +/- Ac. DWELLING UNITS .975 .0425 none 1.01 D. U.'s DWELLING UNITS none D. U.'s +/- Ac. 0.07 +/- Ac. -0- +/ -Ac. Ac 2.16 DWELLING UNITS .975 .0425 none 1.01 D. U.'s DWELLING UNITS none D. U.'s APPLICATION SUPPLEMENT CITY OF ENCINITAS COMMUNITY DEVELOPMENT DEPARTMENT Design Review MUP /MIN X TM/TPM Variance Other. t. Project Description. (Describe proposed project. Describe what you are requesting). 4 Parcel Parcel Map with remainder lot a. b. C. d. e. f. a building sq. ft. N/A exterior materiaVcolor N/A window materiallcolor N/A door materiaVcolor N/A roof materiaVcolor N/A Landscaping Percentage _ Standards: F1 garage sq. ft N/A DENSITY CODE REQUIREMENTS PROJECT Density Range KJMW 0.26 - 0.50 0.50 Net lot area 2.0 2.0 Lot Width 100 280' Cul -de -sac lot width Panhandle lot width 20 20 Lot Depth 150 195' min Front Yard Setback 30 30 min Interior Side Yard Setback 10 /10 10 /10 min Exterior Side Yard Setback 15 15 min Rear Yard Setback 25 25 min Lot Coverage > Building Height 261 Off- Street Parking N/A N/A FAR N/A N/A cnb&A:fMpr15UPPLMNT.D0C (46SOA Community Area OLIVENHAIN Thomas Bros Pg 1.148 General Plan Designation No.Residential 0.26 -0.50 State Coastal Zone? ❑ Yes R] No Number of Proposed Residential Units: Attached N/A Detached N/A Number of Lots 4 + remainder Acres: Gross i5 • ? Net 2.0 Related Case ?: ❑ Yes XJ No If yes, provide previous Case No 2. Existing Conditions. (Describe the existing conditions of the site: i.e., topography, road /alley conditions, access, vegetation, structures, fencing, lot size, drainage and the like). The site is 15+ acres of vacant land Thprp nrp mndpratp to stpap� lopes with one prominant swale running in a northeasterly direction. Vegetation is mostly grasses with comp rnastal sage crrnh, nnA Cha nrrnl lots is proposed via a new private cul -de -sac street which is to connect at Double LL Ranch Road, which is currently a private street with an I.O.D. The main drainage swale, as well as several minor swales drain relatively small areas (about 20 acres total). Drainage flows easterly and parallel to Double LL Ranch Road where it enters a significant watercourse which parallels Lone Jack Road. A 30" watermain traverses parcels 2 & 3. 3. Surrounding Conditions. (Describe the surrounding conditions: i.e., existing structures and relationship to project, # of units, lot sizes, vehicular access, topography, use type and the like). Surrounding land to the west, south and east has already been divided into 2 acre minimum lots. Some residences to the west are currently under construction. Land to the north is approximately 55 acres owned by Chris Lloyd. The site has a barn and horse facilities. Topography of surrounding property is similar to the subject site. Access to land north, east and west is via Double LL Ranch Road and land to the south is accessed from Wieeand Street. CD1ddcAAbaptGSUPPLMNT.DOC (915195) Subject Parcel: North: General Plan Zoning Existing Designation Designation Use Residential 0.25 -0.50 DU/AC Vacant Residential South: Residential East: Residential 11 11 Vacant /Farm Vacant Vacant West: Residential 0.25 -0.50 DU /AC Vacant /Singlel Family 4. ProjecUparcel history. (Describe any past actions taken on this site or project or any other actions taken on development of the site.) The subject property was lot 6 of Map 13320 (TM 93 -029). A Negative Declaration was prepared by Mooney & Associates. CNM-.A l,g'AUPPLMNT OCC (95W S. Project Design. (Describe the design of the project and how it relates to the subject property and adjacent properties and uses). The proposed design of the project is compatible with surrounding development. Most lots in the area are approximately 7 arras in s; azz4ssod by private road. Lots in this vicinity typically develop as estate lots. •6. View Preservation. (Describe what views are being maintained on adjacent properties and those that may be impacted by this project.) Views on adjacent properties will not be impacted by this project because all proposed parcels are at significantly lower elevations NOTE: Items with an asterisk may not be appropriate for all applications. If you have questions regarding applicability to your project, please discuss with Planning Department staff. CO/d&1:NeptZUPPLMNT.COC (DS,9A PROJECT FACILITY AV ABILITY FORM SFWFR Please type o, se pen ORG ZAHOOR ABBASI 738 -7500 ACCT Owner's Name Phone _P _n_ Rnv 4F,7RR5 ACT TASK Owner s Mailing Address Street ESCONDIDO, CA 92046 -2885 DATE AMTS DISTRICT CASHIERS USE ONLY c' IY State Zip SECTIONI1. 'PROJECT DESCRIPTION TO': BE" COMPLETED BY: APPLICANT',.. A. Major Subdivision (TM) e Certificate of Complianco: Assessor's Parcel Number(s) Minor Subdivision (TPM) Boundary Adjustment (Add extra it necessary) Specific Plan or Specific Plan Amendment Rezone (Reclassification) from to zone 2 6 4 2 4 0 1 0 3 Major Use Permit (MUP), purpose: Time Extension... Case No. ' Expired Map... Case No. Other e.1 Residential- Total number of dwelling units 4 Commercial ... Gross floor area Industrial..... Gross floor area Other........ Gross floor area Thomas Bros. Page 1148 Grid B -4 C. Total Project acreage 15.72 Total number of lots 4 Project addressDoubl e LL Ranch Rd. Y. No Sir., D. Is the project proposing its own wastewater treatment plant? ❑ (3 Ol i Venha in , CA 92024 Is the project proposing the use of reclaimed water? ® Commonny r��„�ro ni.msuno0on zc OwnorlApplicant agrees to pay alt necessary construction costs and dedicate all district required easements to extend service to the project. OWNER/APPLICANT MUST COMPLETE ALL CONDITIONS REQUIRED BY THE DISTRICT. Applicant's Signature: -.�_ 'o,.- • Date: Address: Same as Owner ' Phone: (On completion of above, present to the sewer district to establish facility availablllty. Section 2 below) SECTION !2. FACILITY AVAILABILITY TO BEi' COMPLETED cBY DISTRICT ` District name 61RD IFF- SI IPI tr,l lCtJ � L-4 Hr`tN Service area A.E ct Project is in the district. L,l-a ` e C) ❑ Project is not in the district but is within its Sphere of Influence boundary, owner must apply for annexation. ❑ Project is not in the district and is not within its Sphere of Influence boundary. ❑ The project is not located entirely within the district and a potential boundary issue exists with the District. B.❑ Facilities to servo the project 25ARE ❑ARE NOT reasonably expected to be available within the next 5 yearstrasC�tforrthe Explain in space below QLQn attached. �qI mbz�1 she s attached: follow in ❑ Plwect will moo served for the lollowin roason(1 f=Y iS T C: IH Co —( oO q Fi �sfl 1 )EfJ � a P Ei� t � A C.❑ District conditions are attached. Number of sheets attached: �- —I`-- Prlct has specific water reclamation conditions which are attached. Number of sheets attached: rlct will submit conditions at a later date. _ D.❑ How Rr will the plpollne(s) have to be extended to servo the project? I a �T�(Z I-1 1pr= Data �3 R 6 ation ale: Oneyoartrom date Of issuance unless district indicates otherwise) \ Authorized signa�Ctu'r -( Print name: J C'FF7.� r t,o: Print title:_ E53 i✓E WG ii .tt Phone: (0_33 -Z -7Sa NOTE: THIS DOCUMENT Is NOT A COMMITMENT OF FACILITIES OR SERVICE BY THE DISTRICT On completion of Section 2 by the district, applicant is to submit this form with application to the Zoning Counter at the Department of Planning and Land Use, 5201 Ruffin Road, San Diego, CA 92123 01.LfLG -Ms elev.u9 m .PROJECT FACILITY AVAILABILITY FORM - CitY Ol Encinitas WATER Please type or use pen oaG ZA11009 4884T/ 738 -7SOO ACCT Owner's name Phone ACT Po. Box 4(,Z8as — TASK Owners Mailing Address Street 45WON431nO CA g2D44-2$BS DATE AMTS City State Zip DISTRICT CASHIER'S USE ONLY SECTION 1. PROJECT DESCRIPTION TO BE COMPLETED BY APPLICANT Assessor's Parcel Number(s) A. Major Subdivision tTM) 8 Specific Plan or Specific Plan Amendment (Add extra it necessary) Minor Subdivision (TPM) Cerulicale of Compliance: Boundary Adjustment Z G 4 Z-14 O 013 Rezone (Reclassification) from to zone. Major Use Permil (MUP), purpose: Time Extension... Case No �j cxp.red Map... Case No u Other B. Resideneal....... Total number of dwelling units 4 Commercial ...... Gross Iloor area Industrial ........ Gross floor area Thomas Bros. Page 1148 Grid R •4 Other ........... Gross floor area C. Total Project acreage IS .7Z Total number of lots 4 Project address LL iZ4N Suee1 RD D. Is the project proposing the use of groundwater? ❑ Yes !RNo OU VEN FA41N 9Zoz4 Is the project proposing the use of reclaimed water? ❑ Yes ® No Community Planning ArewSubregion Ztp Owner/Applicant agrees to pay all necessary construction costs, dedicate all district required easements to extend service to the project and COMPLETE ALL CONDITIONS REOUIRED BY THE DISTRICT. Applicants Signature: Date: �b Address: SAA ME A-S owly 32 I Phone: (On completion of above, present to the water district to establish facility availability, Section 2 below) I SECTION 2. FACILITY AVAILABILITY TO BE COMPLETED BY DISTRICT I District me Service area A. Project is in the district. ❑ Project is not in the district but is within its Sphere of Influence boundary, owner must apply for annexation. ❑ Pro is not in the district and is not ;thin its Sphere o; influence boundary. ❑ e project is not located entirel ithin the district and a potential boundary issue exists with W.2—District. B. Facilities to serve the project ARE ❑ ARE NOT reasonably expected to be available within !hz next 5 years based on the capital facility plans of the district. Explain in space below or on attached _. (Number of shce,sj ❑ Pro ct will not be served for the following reason(s): —. — C. District condi,inrs are attached. r of sheets attach x':__ C !'Istr:ci has speciiir, water reclamation conditions which a e zttao't r of shrists attac4_d:_- D.v' istrici will sun: ;,it conditions at a later date. oU%1 A, ir will the pipeline(s) have to bo ext nded to serve the project" Date: xpirati da (One year 'rom care of issuance unless disfric indicales otherwise.) I, Auchonzeccj .Vf� -- Pr' name'. l � Printtitic: NOTE: THIS DOCU :XEN'i 1S NOT A CONRYII'PMENT OF SERVICE 0:, .cACI_.TTT.=5 _t Y. THE 'DISTRICT. On completion of Section 2 by the districts .is c.. submit this form with application to the Zoning :'ovnter ai. th_ ?lanrlirta s Communitv Develonment Dr_nt., 527 Encinitas Blvd., Encinitas, CA 92024 PROJECT FACILITY AVAh m rry 1::r)QNA Please typo cruse ell (Two forms are needed if project is to be served separate school districts) ORG ZAHOOR ABBASI 738-7500 ACCT8 Owners Name Phone P.O. BOX 462885 ACT— ELEMENTARY TASK HIGH SCHOOL Owner's Mailing Address 7TI�reoj ESCONDIDO CA 9.2046-2881 DATE UNIFIED DISTRIC T CASHIERS USE ONL Y uty State ZIP 'SECTION Ai , :PROJECT. DESCRIPTION ' TO BEr;COMPLETED"BY:1APPLICANT A. LEGISLATIVE ACT Assessor's Parcel Number(s) Rezone from —zone dens! tyfintensity to zono dons! ty/intensity. (Add extra It necessary) General Plan Amendment Speci tic Plan Specific Plan Amendment 2 6 4 2 4 0 0 B. DEVELOPMENT PROJECT Major Subdivision (TM) Minor Subdivision (TPIA) Boundary Adjustment Major Use Permit (MUP). purpose: Time Extension... Case No. Expired Map... Case No. Other Thomas Bros. Page_IJ-4,LGrid R-4 0.1 Residential....... Total number of dwelling units 4 Project address Double LL Ranch Rd. - Commercial ...... Gross floor area TU—W Industrial........ Gross floor area Olivenhain 92024 Other. : ......... Gross floor area COMMMY Plaming A10W$JX.-g..-n - - - - - - - - 0. Total Project acreage 15. 72 Total number of lots 4 \pplicanCs Signature Z 4- 411. - Date Address Same as Owner A Phone (On completion of above, present to the school district to complete Section 2 below) ::SECTION 2:'- FACILITY AVAILABILITY ..-",...,.'�...��..-.- O,sBE:'COMPLETED.. BY',D [STRICT If not In a unified district, which elementary or District Name' A&c-,'.Au Umi.;ax. 3akaal lly4 - high school district must also fill out a form? Indicate the location and distance of proposed schools of attendance. Elementary a1 1? miles: 3-4 Junior/Middle: — miles:— High schooI• miles:— JO This project will result in the Qverc-rowding of the ,.6;. elelgienlav 9L j ' (check TLI I ec ma 4t-rParWAQCP'RP0SC9'Wther school altte'3n 2X2302 Ra- C3 Fees be i5overnment will levied either in accoince with Code Section 53080 or Section 65970 prior to the issuance of building permits. ❑ Project is located entirely within the district and is eligible for service. ❑ The project is not located entirely within the district and a potential boundary issue may exist with the school district. FOR LEGISLATIVE ACTS (Rezones, General Plan Amendments, Specific Plans) ONLY: ❑ Pursuant to County Ordinance and the Public Facility Element of the General Plan, facilities to serve the project have been committed through a binding agreement satisfactory to the school district. ❑ A binding agreement has not yet been signed, but one will be required prior to legislative approval. 13 No binding ag Ment is necessa Authorized signature: Printnamo: Sharon R. South Print title: chief Finannia] Off iv r Phone: 944-4300-ext. 161 On completion of Section 2 by the district, applicant is to submit this form with application to the Zoning Counter at the Department of Planning and Land Use, 5201 Ruffin Road, San Diego, CA 92123 At any porject in this area even with payment of statutory fees. have capacity for the students. :Z] will result in unmitigated school impacts, We cannot guarantee the local school will � I i r,t ILI I I H,. '_HbILI I Y t-UHM Ctmr Please type se pen I II lL ZAHOOR ABBASI 738 -7500 ORc ACCT Ir Owners name Phone P.O. BOX 462885 ACT Owners mailing address troot ESCONDID02 CA 92046 -2885 TASK AMTb DATE C rty Stafo Zip SECTION I: PROJECT DESCRIPTION DISTRICT CASHIER'S USE ONLY TO "'BE< COMPLETED BY APPLICANT A. Major Subdivision (TM) BSpecificPlanorSpeci ficPlanAmendment Assessor's ParcelNumber(s) Minor Subdivision(TPM) Boundary Adjustment (Addextra if necessary) Certificate of Compliance, purpose: Major Use Permit (MUP), purpose: 2 6 4 2 4 0 0 3 Rezone (Reclassification) from to zone Time Extension... Case No. Expired Map....... Case No. Other 8. Total number of dwelling units 4 1Residential......... Commercial ....... Gross floor area Thomas Bros. Page 1148 Grid B -4 Industrial ............ Gross floor area Other .................. Gross floorarea Project address Double LL Ranch Rd. C. Total Project acreage J.5 &-ao tat lots 4 cmallest proposed lot_ Olivenhain 92024 eon "yPbnninp aWsve.epon —Z-P OWNERIAPPLICANTT AGGREES TO COMPLETE ALL cONDrriONS REQUIRED BY THE DISTRICT. Applicant's signature: P L's_ �� a.{ /� Date: Address: Same as Owner (On completion of above, present to the district that provldos ttro protect! o Phone: n to complete Section 2 and 3 below) ":.:SECTION .2. <FACILITY - AVAILABILITY y � <.TO'`BE COMPLETED BYi`DISTRICT District Name: CN C I IJ t T h 5 - E sLe -D = RA ZT Il t & N T Indicate the location and distance of the r1 r fire station that will serve the proposed project: 71711 V � LL k C, E ?-�, A. Project Is Iq the District and eligible for service. Project is (ot in District but it is within its Sphere of Influence boundary, owner must apply for annexation. Project is not in the District and not within the District's Sphere of Influence. Project is not located entirely within the District and a potential boundary issue exists with the District. 6. Based on the capacity and capability of the District's existing and planned facilities, lire protection facilities are currently adequate or will be adequate to serve the proposed project. The expected emergency travel time to the proposed project is _ minutes. Fire protection facilities are not expected to be adequate to serve the proposed development within the next live C. years. District conditions are attached. The number of shoots attached: District will submit conditions at a later date. SECTION 3. FUELBREAK REOUIREMENTS Note: The tuelbreak requirements Prescribed by tho (ire district for the proposed project do not authorize any clearing prior to project approval by the Department of Planning and Land Use. Within the proposed project_ loot of clearing will be required around all structures. The proposed project is located in a hazardous wildland fire area, and additional fuelbreak requirements may apply. Environmental mitigation requirements should be coordinated the fire with district to ensure that these requirements will not poso firo hazards. Date: y- 1(o —q� Ex irationdata, 9 -1 (0 -9E— (Ono from date /issuance year o unless district indicates otherwise) ^� kj ki- C-A)T„�t J-1 -DFLI �7(art�(o ���rJ AWhvvW,gg.W. Pmt nose ry b Phme On completion of Section 2 and 3 by the District, applicant is to submit this form with application lo: Zoning Counter, Department of Planning and Land Use, 5201 Ruffin Road, Suite B, San Diego, CA 92123 p' VLG A9JF(esv.0 J 1) AUG 03 '98 09 :41AM CTC SUBDIVISOM P. 14, 18 SUBDIVISION GUARANTEE Order No. 7336279 -U52 Fee: $ Dated' July 23, 199e at 7.30 A.V. Subdivision. CHICAGO TITLE INSURANCE COMPANY a corporation, herein called the Company GUARANTEES The County of SAN DIECo and any City within which said Subdivision is located in a sum not exceeding $1,000.00 that, according to those public records which, under the recording laws. impart constructive notice of matters affecting the title to the land included within the exterior boundary shown on the map of the above referenced subdivision, the only parties having any record title interest in said land whose signatures are necessary, under the requirements of the Subdivision Map Act, on the certificates consenting to the recordation of said map and offering for dedication any streets, roads, avenues, and other easements offered for dedication by said map are as set forth in Schedule A. tENGINEERING- 4 1998 Issue/d�w CHI IiIZE INSURANC$ COMPANY CII ENCIN7A$ ES 925 "$" S EET SAN DIEGO, CA 92101 PHONE NO. (619) 239 -6081 FAX NO. (619) 544 -6277 nw John Rau Preticient Thomas J. Adams Secretary QRUC1_0�__'98. _ 09_42FlM CTQ SUBDIVISON F. 15. 18 Dated: July 23, 19! 2C7:30 A.M. MapNo: Subdivision: Fax Number: (619)544 -6292 SCHEDULE A The map hereinbefore referred to is a subdivision of: SEE ATTACHED DESCRIPTION The parties hereinbefore referred to are: 1e11j.i01:t'z XION INVESTMENTS, INC., A CALIFORNIA CORPORATION LESSEES: NONE TRUST DEED HOLDERS: NONE EASEMENT HOLDERS: (1) THE SIGNATURE OF OLIVENHAIN MUNICIPAL WATER DISTRICT, OWNER OF AN EASEMENT AS DISCLOSED BY DEED RECORDED JULY 25, 1977 AS FILE NO. 77- 296591 AND MAY 18, 1993 AS FILE NO. 1993 - 0312187 OF OFFICIAL RECORDS OF SAN DIEGO COUNTY HAS BEEN OMITTED UNDER THE PROVISIONS OF SECTION 66436, SUBSECTION (A)(3)(A)(I) OF GOVERNMENT CODE, THEIR INTEREST IS SUCH THAT IT CANNOT RIPEN INTO A FEE TITLE AND SAID SIGNATURE IS NOT REQUIRED BY THE GOVERNING BODY. (2) THE SIGNATURE OF COUNTY OF SAN DIEGO , OWNER OF AN EASEMENT AS DISCLOSED BY DEED RECORDED JANUARY 31, 1985 AS FILE NO. 1985 - 033895 OF OFFICIAL RECORDS OF SAN DIEGO COUNTY HAS BEEN OMITTED UNDER THE PROVISIONS OF SECTION 66436, SUBSECTION (A)(3)(A)(I) OF GOVERNMENT CODE, THEIR INTEREST IS SUCH THAT IT CANNOT RIPEN INTO A FEE TITLE AND SAID SIGNATURE I5 NOT REQUIRED BY THE GOVERNING BODY. SEE ATTACHED EXHIBIT SUtlUNA - U /II /rN AUG 03 '98 09 :42RM CTC SUBDIVISQN Policy No. Page 1 P.11 13 (3) THE SIGNATURE OF THE CITY OF ENCINITAS, OWNER OF RIGHTS AS DISCLOSED BY DEED RECORDED APRIL 2, 1991 AS FILE NO. 1991 - 0146056 OF OFFICIAL RECORDS OF SAN DIEGO COUNTY HAS BEEN OMITTED UNDER THE PROVISIONS OF SECTION 66436, SUBSECTION (A)(3)(A)(I) OF GOVERNMENT CODE. THEIR INTEREST IS SUCH THAT IT CANNOT RIPEN INTO A FEE TITLE AND SAID SIGNATURE IS NOT REQUIRED BY THE GOVERNING BODY. (4) THE SIGNATURES OF CHRISTOPHER S. LLOYD, A MARRIED MAN NAD CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA Z. LLOYD, DECEASED, PROBATE NO. 15976, OWNERS OF AN EASEMENT AS DISCLOSED BY DEED RECORDED APRIL 19, 1991 AS FILE NO. 1991- 0178724 OF OFFICIAL RECORDS OF SAN DIEGO COUNTY HAS BEEN OMITTED UNDER THE PROVISIONS OF SECTION 66436, SUBSECTION (A)(3)(A)(I) OF GOVERNMENT CODE, THEIR INTEREST IS SUCH THAT IT CANNOT RIPEN INTO A FEE TITLE AND SAID SIGNATURES ARE NOT REQUIRED BY THE GOVERNING BODY. (5) THE SIGNATURE OF DANIELS CABLEVISION INC., OWNER OF AN EASEMENT AS DISCLOSED BY DEED RECORDED APRIL 5, 1994 AS FILE NO. 1994 - 0224539 OF OFFICIAL RECORDS OF SAN DIEGO COUNTY HAS BEEN OMITTED UNDER THE PROVISIONS OF SECTION 66436, SUBSECTION (A)(3)(A)(I) OF GOVERNMENT CODE, THEIR INTEREST IS SUCH THAT IT CANNOT RIPEN INTO A FEE TITLE AND SAID SIGNATURE IS NOT REQUIRED BY THE GOVERNING BODY. giN151Tk :L:]: N. AUG 01 '98 01:39PM CTC SUBDIVISOM Order NO: 7338278 -UF I PARCEL A DESCRIPTION P. 1311,19 LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IV THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAY THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES OVER, UNDER, ALONG AND ACROSS THAT PORTION OF SAID MAP 13320, DESIGNATED AND DELINEATED THEREON AS "PROPOSED PRIVATE STREET EASEMENT EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT S. PARCEL C: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1898, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 596.78 FEET; THENCE NORTH 2025'09" WEST 475.03 FEET; THENCE NORTH 2 °25'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON- TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH SEARS NORTH 67 "43'39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01 °24'26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING; THENCE SOUTH 69 008'08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 007'07^ A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01 015'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PRCPERTY AS DESCRIBED IN EXHIBIT A, SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON- TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH BEARS NORTH 05 °01'36" EAST, THENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25 °53'28" A DISTANCE OF 459.16 FEET; THENCE TANGENT TO SAID CURVE NORTH 69 008'08" EAST, 665.43 FEET TO THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONE JACK ROAD) BEING MC.R50 11Ja /91 M ALIG 01 '98 01 :40PM CTC SUBDIVISON Oder NO: 7338276 -U5 2 DESCRIPTION F. 14 19 A POINT ON THE ARC OF SAID NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72'21'11" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03'13'05" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. AUG 03 '98 09:37AM CTC SUBDIVISON OCHICAGO TITLE COMPANY SECOND AMENDED Reference. MAPPING OF LOT 6 Regarding. LOT 29, PORTION OF APN 264 - 240 -30 ENCINITAS, CA 92024 P. c•18 PRELIMINARY REPORT Dated as of JUly 23, 1998 at 7:30 AM Order No.: 7338278 - U52 CHICAGO TITLE COMPANY hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Policies of Title Insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception in Schedule 6 or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage of said Policy or Policies are set forth in the attached list. Copies of the Policy forms are available upon request Please read the exceptions shown or referred to in Schedule B and the exceptions and exclusions set forth in the attached list of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered It Is important to note that this preliminary report is nut a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. THIS REPORT (AND ANY SUPPLEMENTS OR AMFNDMENTS HERETO) IS ISSUED SOLELY FOR THE PURPOSE OF FACILITATING THE ISSUANCE OF A POLICY OF TITLE INSURANCE AND NO LIABILITY IS ASSUMED HEREBY IF IT IS DESIRED THAT LIABILITY BE ASSUMED PRIOR TO THE ISSUANCE OF A POLICY OF TITLE INSURANCE, A BINOER OR COMMITMENT SHOULD BE REQUESTED. The form of policy of title Insurance contemplated by this report is: CALIFORNIA LAND TITLE ASSOCIATION STANDARD COVERAGE POLIC p �S Title Department: CHICAGO TITLE COMPANY 925 "B'STREET SAN DIEGO, CA. 92101 (619)239-6081 fax:(619)544 -6279 KEN BROWN TITLE OFFICER "P 'V�N'97D. 0 AUG 03 '98 09 :37AM CTC SUBDIVISON P. 3, 12 SCHEDULE A Order No- 7338278 U52 Your Ref: MAPPING OF LOT 5 L The estate or interest in the land hereinafter described or referredto covered by this report is: A FEE AS TO PARCEL A; AN EASEMENT MORE FULLY DESCRTBED BELOW AS TO PARCELS B A%rD C 2. Title to said estate or interest at the date hereof isvested in: XION INVESTMENTS, INC., A CALIFORNIA CORPORATION 3. The land referred to in this report is situated in the State of California, County of SAN DIEGO and is df. ribed as follows: SEE ATTACHED DESCRIPTION AUG 03 '96 09:3741 CTC SUBDIVISON Order No: 7338278 -US 1 DESCRIPTION P.4, 18 LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996 PARCEL B: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES OVER, UNDER, ALONG AND ACROSS THAT PORTION OF SAID MAP 13320, DESIGNATED AND DELINEATED THEREON AS *,PROPOSED PRIVATE STREET EASEMENT ", EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 5. PARCEL C: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY. JUNE 27, 1898, DESCRIBED AS FOLLOWS- BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; :'HENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET; THENCE NORTH 2 025'09" WEST 475.03 FEET; THENCE NORTH 2 °25'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (XNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON- TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL. LINE OF WHICH BEARS NORTH 67 "43'39" EASTI THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01924'26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING. THENCE SOUTH 69908'08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 607'07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01915'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A. SA:D LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON- TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH BEARS NORTH 05901'36" EAST; THENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25053'28" A DISTANCE OF 459.16 FEET; THENCE TANGENT TO SAID CURVE NORTH 69906'09" EAST, 665.43 FEET TO THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONE JACK ROAD) BEING vrsSm0- i2/a /9l M AUG 03 '98 09 :38A1 CTC SUBDIVISON Order No! 7338278 -U5 Ya DESCRIPTION P.5.18 A POINT ON THE ARC OF SAID NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72 921'11" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03013'OS" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. nFSfRSO- Ii; 0.1; SIM AUG 03 '98 09.38AM CTC SUBDIVISON F4ba: t Order No 7338278 U52 SCHEDULE B Your Ref: MAPPING OF LOT 6 At the date hereof exceptions to coverage in addition to the printed Exceptions and Exclusion.% in the policy form designated on the face page of this Report would be as follows: A AP Ac AR AS .,0,31 F.5- U_ 1. PROPERTY TAXES, INCLUDING ANY ASSESSMENTS COLLECTED WITH TAXES, TO BE LEVIED FOR THE FISCAL YEAR 1998 -99 THAT ARE A LIEN NOT YET DUE. 2. PROPERTY TAXES, INCLUDING ANY PERSONAL PROPERTY TAXES AND ANY ASSESSMENTS COLLECTED WITH TAXES, FOR THE FISCAL YEAR 1997 -1998. 1ST INSTALLMENT: PENALTY: 2ND INSTALLMENT: PENALTY AND COST HOMEOWNERS EXEMPTION: CODE AREA: ASSESSMENT NO: $1,616.74 $161.67 (DUE AFTER DECEMBER 10) $1,616,74 $171.67 (DUE A.-TER APRIL 10) $NONE 19073 264- 240 -38 3. SAID PROPERTY HAS BEEN DECLARED TAX - DEFAULTED FOR NON-PAYMENT OF DELINQUENT TAXES FOR FISCAL YEAR 1997 -1998 (AND SUBSEQUENT YEAR$, IF ANY) AMOUNT TO REDEEM: $6,823.36 IF PAID BY. AUGUST 31, 1998 IF PAYMENT IS TO BE MADE THROUGH THIS TITLE ORDER, IN ORDER TO INSURE THAT PAYMENT IS RECEIVED BY THE TAX COLLECTOR IN A TIMELY MANNER, GOOD FUNDS MUST BE IN POSSESSION OF THIS COMPANY AT LEAST 3 BUSINESS DAYS PRIOR TO THE ABOVE DATE. 4. SUPPLEMENTAL OR ESCAPED TAXES FOR THE FISCAL YEAR 19 - -19- ASSESSED PURSUANT TO THE PROVISIONS OF CHAPTER 3.5 (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA. 1ST INSTALLMENT: PENALTY: DELINQUENT: 2ND INSTALLMENT: PENALTY: DELINQUENT: CODE AREA: ASSESSMENT NO., $204.85 $20.48 12/31/1997 $204.85 $30.48 04/30/1998 19073 869- 395 -86 -56 S. SUPPLEMENTAL OR ESCAPED TAXES FOR THE FISCAL YEAR 1997 -1990 ASSESSED PURSUANT TO THE PROVISIONS OF CHAPTER 3.5 (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA. AUG 03 '98 09 :39AM CTC SUBDIVISON SCHEDULE B Page z (continued) OrdcrNO- 7338278 U52 Your Ref: 1ST INSTALLMENT: PENALTY: DELINQUENT: 2ND INSTALU`M1ENT: PENALTY: DELINQUENT: CODE AREA: ASSESSMENT_ NO.: $1,177.70 $117.77 12/31/1997 $2,177.70 $127.77 04/30/1998 19073 879 - 395 -86 -47 MAPPING OF LOT 6 F.Z 18 C 6� THE LIEN OF SUPPLEMENTAL OR ESCAPED ASSESSMENTS OF PROPERTY TAXES, IF ANY, MADE PURSUANT TO THE PROVISIONS OF PART 0.5, CHAPTER 3.5 OR PART 2, CHAPTER 3, ARTICLES 3 AND 4 RESPECTIVELY (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA AS A RESULT OF THE TRANSFER OF TITLE TO THE VESTEE :TAMED IN SCHEDULE A; OR AS A RESULT OF CHANGES IN OWNERSHIP OR NEW CONSTRUCTION OCCURRING PRIOR TO DATE OF POLICY. n 7. AN £ASSMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED T0: OLIVENHAIN MUNICIPAL WATER DISTRICT PURPOSE: A PIPELINE OR PIPELINES FOR ANY AND ALL PURPOSES, TOGETHER WITH THEIR NECESSARY FIXTURES AND APPURTENANCES INCLUDING BUT NOT LIMITED TO FACILITIES FOR POWER TRANSMISSION AND COMMUNICATION PURPOSES RECORDED: JULY 25, 1977 AS FILE NO. 77- 296591, OFFICIAL RECORDS AFFECTS: THE ROUTE AFFECTS A PORTION OF SAID LOT 6 OF SAID LAND AS MORE FULLY DESCRIBED IN SAID DOCUMENT CONSENT OF EXCLUSIVE EASEMENT HOLDER, THE OLIVENHAIN MUNICIPAL WATER DISTRICT RECORDED MAY 24, 1994 AS FILE NO. :994- 0340003 FOR A GRANT OF EASEMENT TO PACIFIC BELL. AF 8. AN EASEMENT FOR TITS PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: THE COUNTY OF SAN DIEGO PURPOSE: OPEN SPACE RECORDED • JANUARY 31, 1985 AS FILE NO. 85- 033895 AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. RESTRICTIONS ON THE USE, BY THE OWNERS OF SAID LAND, OF THE EASEMENT AREA AS SET OUT IN THE EASEMENT DOCUMENT �REIIMpGG; Z! /pith AUG 03 '98 09:39AM CTC SUBDIVISON SCHEDULE B Pd9C 3 (continued) Order No: 7338278 U52 Your RC( MAPPING OF LOT 6 F' . c 18 t 9. AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THERE =N DATED. SEPTEMBER 6, 1990 BY AND BETWEEN. CHRISTOPHER S. LLOYD RECORDED: NOVEMBER 20, 1990 , AS FILE NO. 90- 0624192 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS 10. A COVENANT AND AGREEMENT EXECUTED BY: BARPATT AMERICAN INCORPORATED, IN FAVOR OF: CHRISTOPHER S. LLOYD, RECORDED: FEBRUARY 25, 1991 AS FILE NO. 1991 - 0081600 OF OFFICIAL RECORDS, WHICH, AMONG OTHER THINGS, PROVIDES: IMPROVEMENT OF LONE JACK ROAD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. 11. AN IRREVOCABLE OFFER TO DEDICATE REAL PROPERTY RECORDED APRIL 2, 1991 AS FILE NO. 1991- 0146056, OFFICIAL RECORDS, WHEREIN A PORTION OF SAID LAND WAS OFFERED FOR DEDICATION TO PUBLIC USE, TO THE CITY OF ENCINITAS FOR PUBLIC ROAD AND INCIDENTAL PURPOSES. AFFECTS: AS SHOWN ON SAID MAP N0. 13320 H SAID INSTRUMENT ADDITIONALLY CONTAINS THE PRIVILEGE AND RIGHT TO EXTEND DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SLOPES BEYOND THE LIMITS OF THE ABOVE DESCRIBED RIGHT OF WAY WHERE REQUIRED FOR THE CONSTRUCTION AND MAINTENANCE THEREOF. AG 12. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: CHRISTOPHER S. LLOYD, AND CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA Z. LLOYD, DESEASED, PROBATE NO. 15976. PURPOSE: ROAD AND UTILITY PURPOSES RECORDED: APRIL 19, 1991 AS FILE NO. 1991 - 0178724, OFFICIAL RECORDS AFFECTS: "32' PROPOSED PRIVATE STREET EASEMENT" .� SAID DOCUMENT RECITES IN PART AS FOLLOWS: SAID INSTRUMENT ADDITIONALLY GRANTS THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SOPES AND DRAINAGE FOR THE BENEFIT OF SAID EASEMENT OVER A PORTION OF THE REAL PROPERTY DESCRIBED THEREIN. Ni SAID EASEMENT HAS SEEN CONVEYED AND /OR RESERVED IN VARIOUS OTHER AUG 03 '98 09 :39RM CTC SUBDIVISON F.a -12 SCHEDULE B Pd9C 4 (continued) Order No: 7338279 U52 Your Ref: MAPPING OF LOT 6 INSTRUMENTS OF RECORD. e 13. A DOCUMENT ENTITLED "COVENANT REGARDING REAL PROPERTY: PRIVATE IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY DATED MARCH 6, 1991 EXECUTED BY CHRISTOPHER S. LLOYD, A MARRIED MAN AND CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA Z. LLOYD, DECEASED, PROBATE NO 15976 AND THE CITY OF ENCINITAS , SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED MAY 2, 1991 AS FILE NO. 1991- 0201873, OFFICIAL RECORDS. 6 14. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN ON MAP OF TRACT NO. 12816. EASEMENT PURPOSE- PROPOSED PRIVATE ROAD AFFECTS: AS SHOWN ON SAID MAP EASEMENT PURPOSE: WATER PIPELINES, OTHER DISTRICT FACILITIES AND ALL ACCESS PURPOSES AFFECTS: AS SHOWN ON SAID MAP x 15. COVENANTS, CONDITIONS AND RESTRICTIONS (DELETING THEREFROM ANY RESTRICTIONS BASED ON RACE, COLOR OR CREED) AS SET FORTH IN THE DOCUMENT RECORDED: MARCH 27, 1992 AS FILE NO. 1992- 0175473, OFFICIAL REC rr SAID COVENANTS, CONDITIONS AND RESTRICTIONS PROVIDE THAT A VIOLATION THEREOF SHALL NOT DEFEAT THE LIEN OF ANY MORTGAGE OR DEED OF TRUST MADE IN GOOD FAITH AND FOR VALUE. n 16. AN AGREEMENT. AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: MARCH 25, 1992 BY AND BETWEEN- CHRISTOPHER S. LLOYD, GREGORY CLEARY AND CHRISTOPHER S- LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITA Z. LLOYD DATED SEPTEMBER 11, 1980 RECORDED: MARCH 27, 1992 , AS FILE NO. 1992- 0175474 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE & COST SHARING REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULAA5. 0 17. AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: MAY 7, 1993 BY AND BETWEEN: OLIVENHAIN MUNICIPAL WATER DISTRICT, A MUNICIPAL WATER PAE.ur9C 912V=k PUG 03 '98 e9:40AM CTC SUBDIVISON P. 10, 18 SCHEDULE B Pagc 5 (continued) Order NO: 7338278 U52 YOU, Rd MAPPING OF LOT 6 DISTRICT AND CHATS LLOYD RECORDED: MAY 18, 1993 AS FILE NO. 1993- 0312187 OF OFFICIAL RECORDS REGARDING: AGREEMENT TO PROVIDE WATER SERVICE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. a 18. A COVENANT AND AGREEMENT EXECUTED BY: CHRISTOPHER LLOYD, TRUSTEE IN FAVOR OF: CITY OF ENCINITAS RECORDED? AUGUST 27, 1993 AS FILE NO. 1993- 0563741, OFFICIAL RECORDS WHICH AMONG OTHER THINGS PROVIDES: A. PARK FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL SUM ($8,409.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR FINAL PARCEL MAP #92 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($2,803.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. B. TRAFFIC FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL SUN. ($2,703.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR MAP #92 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($901.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. S 19. A COVENANT AND AGREEMENT EXECUTED BY! CHRISTOPHER S. LLOYD, TRUSTEE AND GREGORY CLEARY IN FAVOR OF: CITY OF ENCINITAS RECORDED: OCTOBER 20, 1993 AS FILE NO. 1993 - 0700454, OFFICIAL RECORDS WHICH AMONG OTHER THINGS PROVIDES FLOOD CONTROL FEES SHALL SE ASSESSED AND COLLECTED DURING THE BUILDING PERMIT PROCESSING PRIOR TO THE CONSTRUCTION OF ANY IMPERVIOUS SURFACE z 20. COVENANT REGARDING REAL PROPERTY AND INDEMNIFICATION AGREEMENT BY AND BETWEEN CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITY Z. LLOYD DATED SEPTEMBER 11, 1980; CHRISTOPHER S. LLOYD, a married man as his sole and separate property; AND GREGORY CLEARY, a married man as his sole and separate property, AND EUGENE AND BARBARA HIRSCHKOFF RECORDED DECEMBER 2, 1993 AS FILE NO. 1993- 0812962, OFFICIAL RECORDS. REFERENCE I5 MADE TO SAID DOCUMENT FOR FULL PARTICULARS_ v 21. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT ORELN8C 9i734U7 AUG 03 '98 09:40RM CTC SUBDIVISON SCHEDULE B Pagc 6 (continued) Order No: 7338278 U52 Your Ref. MAPPING OF LOT 6 P.11 18 GRANTED TO: DANIELS CABLEVISION INC. PURPOSE: CABLE TELEVISION SYSTEM AND ACCESS RECORDED: APRIL 5, 1994 AS FILE NO. 1994- 0224539, OFFICIAL RECORDS AFFECTS: THE EXACT LOCATION AND EXTENT OF SAID EASEMENT IS NOT DISCLOSED OF RECORD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS w 22. EASEMENTS FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN OR AS OFFERED FOR DEDICATION ON THE RECORDED MAP SHOWN BELOW. MAP OF: TRACT NO 13320 EASEMENT PURPOSE: PROPOSED PRIVATE STREET AFFECTS: AS SHOWN THEREON z 23. ANY EASEMENT OR OTHER RIGHTS WHICH MAY EXIST OVER SAID LAND, AS DISCLOSED ON A COPY OF THE MAP OF TRACT NO. 13320 FILED IN THE OFFICE OF THE COUNTY ROAD COMMISSIONER AND REFERRED TO IN THE DED. *CATION CLAUSE OF THE RECORDED MAP OF SAID TRACT. r 24. A COVENANT AND AGREEMENT UPON AND SUBJECT TO THE TERMS AND CONDITIONS THEREIN EXECUTED BY. CHRISTOPHER S. LLOYD AND GREGORY CLEARY IN FAVOR OF. THE CITY OF ENCINITAS RECORDED: APRIL 25, 1996 AS FILE NO. 1996 - 0207397, OFFICIAL RECORDS REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. z THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTI.NUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. AA 25. A DOCUMENT ENTITLED "LIEN COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY ", DATED MARCH 28, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CLEARY, SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED APRIL 25, 1996 AS FILE NO. 1996 - 0207398, OFFICIAL RECORDS. A6 THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AUG 03 '98 09 :40AM CTC SUBDIvISOri P.12 '18 SCHEDULE $ Page 7 (continued) Ordcr No' 7338278 U52 Your ReL MAPPING OF LOT 6 AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. AC 26. A DOCUMENT ENTITLED "COVENANT REGARDING REAL PROPERTY WAIVER OF PROTEST TO ASSESSMENTS ", DATED MARCH 27, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CL EAR Y, SVB.TECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED APRIL 25, 1996 AS FILE NO. 1996 - 0207399, OFFICIAL RECORDS. An THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY F -=E OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. ,v 27. EASEMENTS FOR INGRESS AND EGRESS, PIPELINES, DRAINAGE ANDIOR PUBLIC UTILITIES AND INCIDENTAL PURPOSES THERETO OVER, UNDER, ALONG AND ACROSS THE EASEMENT PARCEL(S) HEREIN DESCRIBED AS GRANTED AND /OR RESERVED IN VARIOUS DEED$ OF RECORD. AFFECTS. PARCELS B AND C AJ 28. MATTERS WHICH MAY BE DISCLOSED BY AN INSPECTION OR SURVEY OF SAID LAND OR BY INQUIRY OF THE PARTIES IN POSSESSION THEREOF. nr; END OF SCHEDULE 8 AN NOTE NO. 1: BEFORE ISSUING ITS POLICY OF TITLE INSURANCE, THIS COMPANY WILL REQUIRE EVIDENCE, SATISFACTORY TO THE COMPANY, THAT XION INVESTMENTS, INC.. A CALIFORNIA CORPORATION I5 VALIDLY FORMED AND IN GOOD STA- 'QDING ON THE DATE WHEN DOCUMENTS IN THIS TRANSACTION ARE TO BE EXECUTED. ANY INSTRUMENT IN WRITING IN THE NAME OF THE CORPORATION WILL BE SUFFICIENT FOR TITLE INSURANCE PURPOSES IF, PURSUANT TO SECTION 5212 OF THE CALIFORNIA CORPORATIONS CODE, IT IS SIGNED AND ACKNOWLEDGED BY ANY ONE OF THE FOLLOWING OFFICERS: ° THE CHAIRMAN OF THE BOARD OF DIRECTORS, e THE PRESIDENT, ANY VICE PRESIDENT AND PROVIDED IT IS ALSO SIGNED BY ANY ONE OF THE FOLLOWING ADDITIONAL OFFICERS: • THE SECRETARY, • ANY ASSISTANT SECRETARY, • CHIEF FINANCIAL OFFICER, • ASSISTANT TREASURER. ANY DEVIATION FROM THE ABOVE WILL REQUIRE THE SUBMISSION TO THIS COMPANY OF PAEJMBC 0,'77/03bk AUG 03 '98 09 :41AM CTC SUBDIVISON F.13 i SCHEDULE B Page a (continued) Order No: 7338278 U52 Your Ref: MAPPING OF LOT 6 A RESOLUTION OF THE GOVERNING BODY OF SAID CORPORATION AUTHORIZING THE TRANSACTION FOR WHICH THIS REPORT HAS BEEN REQUESTED, TOGETHER W:TH A COPY OF SUCH CORPORATION'S BY -LAWS. THE RESOLUTION TO DESIGNATE AS WELL, THE OFFICERS AUTHORIZED TO EXECUTE ON THE CORPORATION'S BEHALF. AL NOTE: IF THIS COMPANY IS REQUESTED TO DISBURSE FUNDS IN CONNECTION WITH THIS TRANSACTION, CHAPTER 598, STATUTES OF 1989 MANDATES HOLD PERIODS FOR CHECKS DEPOSITED TO ESCROW OR SUB- ESCROW ACCOUNTS. THE MANDATORY HOLD PERIOD FOR CASHIER'S CHECKS, CERTIFIED CHECKS AND TELLER'S CHECKS IS ONE BUSINESS DAY AFTER THE DAY DEPOSITED. OTHER CHECKS REQUIRE A HOLD PERIOD FROM THREE TO SEVEN BUSINESS DAYS AFTER THE DAY DEPOSITED. NOTES ANY FUNDING WIRES TO CHICAGO TITLE COMPANY ARE TO BE DIRECTED AS FOLLOWS. SANK OF AMERICA 1650 GATEWAY BOULEVARD CONCORD, CALIFORNIA ABA 121 - 000358 CREDIT TO CHICAGO TITLE SUB- ESCROW DEPOSITORY ACCOUNT NO. 12353 -50752 FURTHER CREDIT TO ORDER NO! 007338278 ATTN: KEN BROWN TITLE OFFICER m DP vac - wac- s;n�83 c SCHEDULE A Ktss I N` �jeO ~ -loop- TITL )rdcr No: 7338278 U52 ' Your Ref: MAPPING OF LOT 6 1. The estate or interest in the land hereinafter described or referred to covered by this report is: A FEE AS TO PARCEL A; AN EASEMENT MORE FULLY DESCRIBED BELOW AS TO PARCELS B AND C 2. Title to said estato or interest at the date hereof is vested in: DEVELOPMENT PLANNING CONSULTANTS INTERNATIONAL, INC., A CALIFORNIA CORPORATION ENG INEE FI EµC01 S ES GIV OF 3. The land referred to in this report is situated in the State of California, County of SAN DIEGO and is described as follows: SEE ATTACHED DESCRIPTION PRELI6 - R /27/Mbk Order NO: 7338278 U52 PARCEL A: DESCRIPTION LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES OVER, UNDER, ALONG AND ACROSS THAT PORTION OF SAID MAP 13320, DESIGNATED AND DELINEATED THEREON AS "PROPOSED PRIVATE STREET EASEMENT ", EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 5. PARCEL C AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1898, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET; THENCE NORTH 2 025'09" WEST 475.03 FEET; THENCE NORTH 2025'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67043'39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01024'26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING; THENCE SOUTH 69 °08'08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22007'07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01015'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A, SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON- TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH BEARS NORTH 05001'36" EAST; THENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25053'28" A DISTANCE OF 459.16 FEET; THENCE TANGENT TO SAID CURVE NORTH 69008'08" EAST, 665.43 FEET TO 1 Order No: 7338278 U52 DESCRIPTION THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONE JACK ROAD) BEING A POINT ON THE ARC OF SAID NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72 °21'11" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03 °13'05" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. SCHEDULE B Page 1 Ordcr No: 7338278 U52 Your Ref: MAPPING OF LOT 6 At the dale hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in the policy form designated on the face page of this Report would be as follows: A 1. PROPERTY TAXES, INCLUDING ANY ASSESSMENTS COLLECTED WITH TAXES, TO BE LEVIED FOR THE FISCAL YEAR 1997 -98 THAT ARE A LIEN NOT YET DUE. „ 2. PROPERTY TAXES, INCLUDING ANY PERSONAL PROPERTY TAXES AND ANY ASSESSMENTS COLLECTED WITH TAXES, FOR THE FISCAL YEAR 1996 -1997. 1ST INSTALLMENT 2ND INSTALLMENT HOMEOWNERS EXEMPTION: CODE AREA: ASSESSMENT 'NO: $3,756.74 PAID $3,756.74 PAID $NONE 19073 264 - 240 -30 -OC AFFECTS THIS PROPERTY WITH OTHER PROPERTY. c 3. THE LIEN OF'SUPPLEMENTAL OR ESCAPED ASSESSMENTS OF PROPERTY TAXES, IF ANY, MADE PURSUANT TO THE PROVISIONS OF PART 0.5, CHAPTER 3.5 OR PART 2, CHAPTER 3, ARTICLES 3 AND 4 RESPECTIVELY (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA AS A RESULT OF THE TRANSFER OF TITLE TO THE VESTEE NAMED IN SCHEDULE A; OR AS A RESULT OF CHANGES IN OWNERSHIP OR NEW CONSTRUCTION OCCURRING PRIOR TO DATE OF POLICY. D 1/4. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: OLIVENHAIN MUNICIPAL WATER DISTRICT PURPOSE: A PIPELINE OR PIPELINES FOR ANY AND ALL PURPOSES, TOGETHER WITH THEIR NECESSARY FIXTURES AND APPURTENANCES INCLUDING BUT NOT LIMITED TO FACILITIES FOR POWER TRANSMISSION AND COMMUNICATION PURPOSES RECORDED: JULY 25, 1977 AS FILE NO. 77- 296591, OFFICIAL RECORDS AFFECTS: THE ROUTE AFFECTS A PORTION OF SAID LOT 6 OF SAID LAND AS MORE FULLY DESCRIBED IN SAID DOCUMENT CONSENT OF EXCLUSIVE EASEMENT HOLDER, THE OLIVENHAIN MUNICIPAL WATER DISTRICT RECORDED MAY 24, 1994 AS FILE NO. 1994- 0340003 FOR A GRANT OF / EASEMENT TO PACIFIC BELL. AF V 5. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: THE COUNTY OF SAN DIEGO PRELIM &8 17/91.11c P49C 2 Order No: 7338278 U57, SCHEDULE B (continued) Your Ref: MAPPING OF LOT 6 PURPOSE: OPEN SPACE RECORDED: JANUARY 31, 1985 AS FILE NO. 85- 033895 AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. RESTRICTIONS ON THE USE, BY THE OWNERS OF SAID LAND, OF THE EASEMENT AREA AS SET OUT IN THE EASEMENT DOCUMENT E ✓ 6, AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: SEPTEMBER 6, 1990 BY AND BETWEEN: CHRISTOPHER S. LLOYD RECORDED: NOVEMBER 20, 1990 AS FILE NO. 90- 0624192 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS r 7. A COVENANT AND AGREEMENT EXECUTED BY: BARRATT AMERICAN INCORPORATED, IN FAVOR OF: CHRISTOPHER S. LLOYD, RECORDED: FEBRUARY 25, 1991 AS FILE NO. 1991 - 0081600 OF OFFICIAL RECORDS, WHICH, AMONG ETHER THINGS, PROVIDES: IMPROVEMENT OF LONE JACK ROAD. REFERENCE IS.MADE TO SAID DOCUMENT FOR FULL PARTICULARS. r./ B. AN IRREVOCABLE OFFER TO DEDICATE REAL PROPERTY RECORDED APRIL 2, 1991 AS •V/ FILE NO. 1991 - 0146056, OFFICIAL RECORDS, WHEREIN A PORTION OF SAID LAND WAS OFFERED FOR DEDICATION TO PUBLIC USE FOR PUBLIC ROAD AND INCIDENTAL PURPOSES. AFFECTS: AS SHOWN ON SAID MAP NO. 13320 SAID INSTRUMENT ADDITIONALLY CONTAINS THE PRIVILEGE AND RIGHT TO EXTEND DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SLOPES BEYOND THE LIMITS OF THE ABOVE DESCRIBED RIGHT OF WAY WHERE REQUIRED FOR THE CONSTRUCTION AND MAINTENANCE THEREOF. t 9. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT PURPOSE: ROAD AND UTILITY RECORDED: APRIL 19, 1991 AS FILE NO. 1991 - 0178724, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND CHICAGO TT_ E COMPANY Issuing Office: 925 B STREET SAN DIEGO,CA 92101 (619)239 -6081 STEVE BUNDY PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SOLANA BEACH, CA 92075 o �c�odI rr Order No. 007338278 U52 SUITE "A" Reference: MAPPING OF LOT 6 Regarding: LOT 29, PORTION OF APN 264 - 240 -30 ENCINITAS, CA Dated as of September 2, 1997 at 7:30 AM In response to the above referenced application for a policy of title insurance, CHICAGO TITLE COMPANY hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Politics of Title Insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception in Schedule B or not excluded from coverage pursuant to the printed Schedules, Conditions and Sfipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage of said Policy or Policies arc set forth in Exhibit A attached list. Copies of the Policy forms should be read. They arc available from the office which issued the report. Please read the exceptions shown or referred to in Schedule B and the exceptions and exclusions set forth in Exhibit A of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. THIS REPORT (AND ANY SUPPLEMENTS OR AMENDMENTS HERETO) IS ISSUED SOLELY FOR THE PURPOSE OF FACILITATING THE ISSUANCE OF A POLICY OF TITLE INSURANCE AND NO LIABILITY IS ASSUMED HEREBY. IF IT IS DESIRED THAT LIABILITY BE ASSUMED PRIOR TO THE ISSUANCE OF A POLICY OF TITLE INSURANCE, A BINDER OR COMMITMENT SHOULD BE REQUESTED. The form of policy of title insurance contemplated by this report is: CALIFORNIA LAND TITLE ASSOCIATION STANDARD COVERAGE POLICY Title Officcr KEN BROWN vrvn+- 11107/04M SCHEDULE A Ordcr No: 7338278 U52 Your Ref: MAPPING OF LOT 6 1. The estate or interest in the land hereinafter described or referred to covered by this report is: A FEE AS TO PARCEL A; AN EASEMENT MORE FULLY DESCRIBED BELOW AS TO PARCELS B AND C 2. Tills to said estate or interest at the date hereof is vested in: DEVELOPMENT PLANNING CONSULTANTS INTERNATIONAL, INC., A CALIFORNIA CORPORATION 3. The land referred to in this report is situated in the State of California, County of SAN DIEGO and is described as follows: SEE ATTACHED DESCRIPTION Order No: 7338278 ' U52 DESCRIPTION PARCEL A: LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES OVER, UNDER, ALONG AND ACROSS THAT PORTION OF SAID MAP 13320, DESIGNATED AND DELINEATED THEREON AS "PROPOSED PRIVATE STREET EASEMENT ", EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 5. PARCEL C: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1898, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET; THENCE NORTH 2 025'09" WEST 475.03 FEET; THENCE NORTH 2 025'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67 "43.39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01 024'26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING; THENCE SOUTH 69 °08'08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 007'07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01015'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A, SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON - TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH BEARS NORTH 05 001'36" EAST; THENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25 053'28" A DISTANCE OF 459.16 FEET; THENCE TANGENT TO SAID CURVE NORTH 69 008'08" EAST, 665.43 FEET TO 1 Order NO: 7338278 U52 DESCRIPTION THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONE SACK ROAD) BEING A POINT ON THE ARC OF SAID NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72 021111" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03 013'05" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. Page 1 Ordcr No: 7338278 SCHEDULE B U52 Your Rcf: MAPPING OF LOT 6 Al the dale hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in the policy form designated on the face page of this Report would be as follows: A 1. PROPERTY TAXES, INCLUDING ANY ASSESSMENTS COLLECTED WITH TAXES, TO BE LEVIED FOR THE FISCAL YEAR 1997 -98 THAT ARE A LIEN NOT YET DUE. a 2. PROPERTY TAXES, INCLUDING ANY PERSONAL PROPERTY TAXES AND ANY ASSESSMENTS COLLECTED WITH TAXES. FOR THE FISCAL YEAR 1996 -1997. 1ST INSTALLMENT: 2ND INSTALLMENT: HOMEOWNERS EXEMPTION: CODE AREA: ASSESSMENT NO: $3,756.74 PAID $3,756.74 PAID $NONE 19073 264 - 240 -30 -00 AFFECTS THIS PROPERTY WITH OTHER PROPERTY. 3. THE LIEN OF SUPPLEMENTAL OR ESCAPED ASSESSMENTS OF PROPERTY TAXES, IF ANY, MADE PURSUANT TO THE PROVISIONS OF PART 0.5, CHAPTER 3.5 OR PART 2, CHAPTER 3, ARTICLES 3 AND 4 RESPECTIVELY (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA AS A RESULT OF THE TRANSFER OF TITLE TO THE VESTEE NAMED IN SCHEDULE A; OR AS A RESULT OF CHANGES IN OWNERSHIP OR NEW CONSTRUCTION OCCURRING PRIOR TO DATE OF POLICY. �r 4. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: OLIVENHAIN MUNICIPAL WATER DISTRICT PURPOSE: A PIPELINE OR PIPELINES FOR ANY AND ALL PURPOSES, TOGETHER WITH THEIR NECESSARY FIXTURES AND APPURTENANCES INCLUDING BUT NOT LIMITED TO FACILITIES FOR POWER TRANSMISSION AND COMMUNICATION PURPOSES RECORDED: JULY 25, 1977 AS FILE NO. 77- 296591, OFFICIAL RECORDS AFFECTS: THE ROUTE AFFECTS A PORTION OF SAID LOT 6 OF SAID LAND AS MORE FULLY DESCRIBED IN SAID DOCUMENT CONSENT OF EXCLUSIVE EASEMENT HOLDER, THE OLIVENHAIN MUNICIPAL WATER DISTRICT RECORDED MAY 24, 1994 AS FILE NO. 1994 - 0340003 FOR A GRANT OF EASEMENT TO PACIFIC BELL. ne S. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: THE COUNTY OF SAN DIEGO PRELIMB 9 /7/91 he Pa9C 2 SCHEDULE B (continued) Order Nu: 7338278 U52 Your Rcf: MAPPING OF LOT 6 PURPOSE: OPEN SPACE RECORDED: JANUARY 31, 1965 AS FILE NO. 85- 033895 AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. RESTRICTIONS ON THE USE, BY THE OWNERS OF SAID LAND, OF THE EASEMENT AREA AS SET OUT IN THE EASEMENT DOCUMENT E 6. AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: SEPTEMBER 6, 1990 BY AND BETWEEN: CHRISTOPHER S. LLOYD RECORDED: NOVEMBER 20, 1990 , AS FILE NO. 90- 0624192 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS F 7. A COVENANT AND AGREEMENT EXECUTED BY: BARRATT AMERICAN INCORPORATED, IN FAVOR OF: CHRISTOPHER S. LLOYD, RECORDED: FEBRUARY 25, 1991 AS FILE NO. 1991 - 0081600 OF OFFICIAL RECORDS, WHICH, AMONG OTHER THINGS, PROVIDES: IMPROVEMENT OF LONE JACK ROAD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. c 8. AN IRREVOCABLE OFFER TO DEDICATE REAL PROPERTY RECORDED APRIL 2, 1991 AS FILE NO. 1991- 0146056, OFFICIAL RECORDS, WHEREIN A PORTION OF SAID LAND WAS OFFERED FOR DEDICATION TO PUBLIC USE FOR PUBLIC ROAD AND INCIDENTAL PURPOSES. AFFECTS: AS SHOWN ON SAID MAP NO. 13320 H SAID INSTRUMENT ADDITIONALLY CONTAINS THE PRIVILEGE AND RIGHT TO EXTEND DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SLOPES BEYOND THE LIMITS OF THE ABOVE DESCRIBED RIGHT OF WAY WHERE REQUIRED FOR THE CONSTRUCTION AND MAINTENANCE THEREOF. r 9. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT PURPOSE: ROAD AND UTILITY RECORDED: APRIL 19, 1991 AS FILE NO. 1991-0178724, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND PRELIMBG9/23/9 bk PagC 3 Ordcr No: 7336278 U52 SCHEDULE B (continued) Ynur Rcf: MAPPING OF LOT 6 IS MORE FULLY DESCRIBED IN SAID DOCUMENT. ., SAID DOCUMENT RECITES IN PART AS FOLLOWS: SAID INSTRUMENT ADDITIONALLY GRANTS THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SOPES AND DRAINAGE FOR THE BENEFIT OF SAID EASEMENT OVER A PORTION OF THE REAL PROPERTY DESCRIBED THEREIN. K 10. A DOCUMENT ENTITLED "COVENANT REGARDING REAL PROPERTY: PRIVATE IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY DATED MARCH 6, 1991 EXECUTED BY CHRISTOPHER S. LLOYD, A MARRIED MAN AND CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA Z. LLOYD, DECEASED, PROBATE NO. 15976 AND THE CITY OF ENCINITAS , SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED MAY 2, 1991 AS FILE NO. 1991 - 0201873, OFFICIAL RECORDS. L 11. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN ON MAP OF TRACT NO. 12816. EASEMENT PURPOSE: PROPOSED PRIVATE ROAD AFFECTS: AS SHOWN ON SAID MAP EASEMENT PURPOSE: WATER PIPELINES, OTHER DISTRICT FACILITIES AND ALL ACCESS PURPOSES AFFECTS: AS SHOWN ON SAID MAP n 12. COVENANTS, CONDITIONS AND RESTRICTIONS (DELETING THEREFROM ANY RESTRICTIONS BASED ON RACE, COLOR OR CREED) AS SET FORTH IN THE DOCUMENT RECORDED: MARCH 27, 1992 AS FILE NO. 1992- 0175473, OFFICIAL REC N SAID COVENANTS, CONDITIONS AND RESTRICTIONS PROVIDE THAT A VIOLATION THEREOF SHALL NOT DEFEAT THE LIEN OF ANY MORTGAGE OR DEED OF TRUST MADE IN GOOD FAITH AND FOR VALUE. c' 13. AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: MARCH 25, 1992 BY AND BETWEEN: CHRISTOPHER S. LLOYD, GREGORY CLEARY AND CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITA Z. LLOYD DATED SEPTEMBER 11, 1980 RECORDED: MARCH 27, 1992 , AS FILE NO. 1992 - 0175474 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE & COST SHARING PWLIMB - 9/2319 SCHEDULE B Pa9c 4 (continued) Order No: 7338278 U52 Your Rcf: MAPPING OF LOT 6 REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. 14. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT PURPOSE: INGRESS AND EGRESS, ROAD AND UTILITIES AS GRANTED /RESERVED BY VARIOUS INSTRUMENTS OF RECORD, ONE OF WHICH RECORDED MARCH 27, 1992 AS FILE NO. 1992- 0175477, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. � 15. AN AGREEMENT, AND THE TERMS.AND CONDITIONS AS CONTAINED THEREIN DATED: MAY 7, 1993 BY AND BETWEEN: OLIVENHAIN MUNICIPAL WATER DISTRICT, A MUNICIPAL WATER DISTRICT AND CHRIS LLOYD RECORDED: MAY 18, 1993 AS FILE NO. 1993- 0312187 OF OFFICIAL RECORDS REGARDING: AGREEMENT TO PROVIDE WATER SERVICE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. R 16. A COVENANT AND AGREEMENT EXECUTED BY: CHRISTOPHER LLOYD, TRUSTEE IN FAVOR OF: CITY OF ENCINITAS RECORDED: AUGUST 27, 1993 AS FILE NO. 1993 - 0563741, OFFICIAL RECORDS WHICH AMONG OTHER THINGS PROVIDES: A. PARK FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL SUM ($8,409.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR FINAL PARCEL MAP #92 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($2,803.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. B. TRAFFIC FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL SUM ($2,703.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR MAP 492 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($901.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. s 17. A COVENANT AND AGREEMENT EXECUTED BY: CHRISTOPHER S. LLOYD, TRUSTEE AND GREGORY CLEARY IN FAVOR OF: CITY OF ENCINITAS RECORDED: OCTOBER 20, 1993 AS FILE NO. 1993- 0700454, OFFICIAL RECORDS MEIIMBC B /P] /BJbk Page 5 Order No: 7338278 U52 SCHEDULE B (continued) Your RUE MAPPING OF LOT 6 WHICH AMONG OTHER THINGS PROVIDES: FLOOD CONTROL FEES SHALL BE ASSESSED AND COLLECTED DURING THE BUILDING PERMIT PROCESSING PRIOR TO THE CONSTRUCTION OF ANY IMPERVIOUS SURFACE r 18. COVENANT REGARDING REAL PROPERTY AND INDEMNIFICATION AGREEMENT BY AND BETWEEN CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITY Z. LLOYD DATED SEPTEMBER 11, 1980; CHRISTOPHER S. LLOYD, a married man as his sole and separate property; AND GREGORY CLEARY, a married man as his sole and separate property, AND EUGENE AND BARBARA HIRSCHKOFF RECORDED DECEMBER 2, 1993 AS FILE NO. 1993 - 0812962, OFFICIAL RECORDS. u REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. v 19. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: DANIELS CABLEVISION INC. PURPOSE: CABLE TELEVISION SYSTEM AND ACCESS RECORDED: APRIL 5, 1994 AS FILE NO. 1994 - 0224539, OFFICIAL RECORDS AFFECTS: THE EXACT LOCATION AND EXTENT OF SAID EASEMENT IS NOT DISCLOSED OF RECORD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS w 20. EASEMENTS FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN OR AS OFFERED FOR DEDICATION ON THE RECORDED MAP SHOWN BELOW. MAP OF: TRACT NO. 13320 EASEMENT PURPOSE: PROPOSED PRIVATE STREET AFFECTS: AS SHOWN THEREON x 21. ANY EASEMENT OR OTHER RIGHTS WHICH MAY EXIST OVER SAID LAND, AS DISCLOSED ON A COPY OF THE MAP OF TRACT NO. 13320 FILED IN THE OFFICE OF THE COUNTY ROAD COMMISSIONER AND REFERRED TO IN THE DEDICATION CLAUSE OF THE RECORDED MAP OF SAID TRACT. r 22. A COVENANT AND AGREEMENT UPON AND SUBJECT TO THE TERMS AND CONDITIONS THEREIN EXECUTED BY: CHRISTOPHER S. LLOYD AND GREGORY CLEARY IN FAVOR OF: THE CITY OF ENCINITAS RECORDED: APRIL 25, 1996 AS FILE NO. 1996 - 0207397, OFFICIAL RECORDS SCHEDULE B Page 6 (continued) Order No: 7338278 U52 Your Ref: MAPPING OF LOT 6 REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. z THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. .0 23. A DOCUMENT ENTITLED "LIEN COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY ", DATED MARCH 28, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CLEARY, SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED APRIL 25, 1996 AS FILE NO. 1996 - 0207398, OFFICIAL RECORDS. AD THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. AC 24. A DOCUMENT ENTITLED "COVENANT REGARDING REAL PROPERTY WAIVER OF PROTEST TO ASSESSMENTS ", DATED MARCH 27, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CLEARY, SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, RECORDED APRIL 2S, 1996 AS FILE NO. 1996 - 0207399, OFFICIAL RECORDS. AD THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. AE i25 AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT l GRANTED TO: OLIVENHAIN MUNICIPAL WATER DISTRICT, A PUBLIC AGENCY PURPOSE: PIPELINE OR PIPELINES AND APPURTENANCES, TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS RECORDED: APRIL 25, 1996 AS FILE NO. 1996- 0207710, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. AG/ 26. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED T0: CHRIS D. MYERS PURPOSE: ROAD AND UTILITY PURPOSES RECORDED: JULY 9, 1997 AS FILE NO. 1997 - 0323724, OFFICIAL RECORDS PREIIMOC 9123193b Page 7 Order No: 7338278 U52 SCHEDULE B (continued) Your Ref: MAPPING OF LOT 6 AFFECTS: "PROPOSED PRIVATE STREET EASEMENT" All SAID EASEMENT HAS BEEN CONVEYED AND /OR RESERVED IN VARIOUS OTHER INSTRUMENTS OF RECORD. Al 27. EASEMENTS FOR INGRESS AND EGRESS, PIPELINES, DRAINAGE AND /OR PUBLIC UTILITIES AND INCIDENTAL PURPOSES THERETO OVER, UNDER, ALONG AND ACROSS THE EASEMENT PARCEL(S) HEREIN DESCRIBED AS GRANTED AND /OR RESERVED IN VARIOUS DEEDS OF RECORD. AFFECTS: PARCELS B AND C ai 28. MATTERS WHICH MAY BE DISCLOSED BY AN INSPECTION OR SURVEY OF SAID LAND OR BY INQUIRY OF THE PARTIES IN POSSESSION THEREOF. AR END OF SCHEDULE B AN NOTE NO. 1: BEFORE ISSUING ITS POLICY OF TITLE INSURANCE, THIS COMPANY WILL REQUIRE EVIDENCE, SATISFACTORY TO THE COMPANY, THAT DEVELOPMENT PLANNING CONSULTANTS INTERNATIONAL, INC. IS VALIDLY FORMED AND IN GOOD STANDING ON THE DATE WHEN DOCUMENTS IN THIS TRANSACTION ARE TO BE EXECUTED, ANY INSTRUMENT IN WRITING IN THE NAME OF THE CORPORATION WILL BE SUFFICIENT FOR TITLE INSURANCE PURPOSES IF, PURSUANT TO SECTION 5212 OF THE CALIFORNIA CORPORATIONS CODE, IT IS SIGNED AND ACKNOWLEDGED BY ANY ONE OF THE FOLLOWING OFFICERS: • THE CHAIRMAN OF THE BOARD OF DIRECTORS, • THE PRESIDENT, • ANY VICE PRESIDENT AND PROVIDED IT IS ALSO SIGNED BY ANY ONE OF THE FOLLOWING ADDITIONAL OFFICERS: • THE SECRETARY, • ANY ASSISTANT SECRETARY, • CHIEF FINANCIAL OFFICER, • ASSISTANT TREASURER. ANY DEVIATION FROM THE ABOVE WILL REQUIRE THE SUBMISSION TO THIS COMPANY OF A RESOLUTION OF THE GOVERNING BODY OF SAID CORPORATION AUTHORIZING THE TRANSACTION FOR WHICH THIS REPORT HAS BEEN REQUESTED, TOGETHER WITH A COPY OF SUCH CORPORATION'S BY -LAWS. THE RESOLUTION TO DESIGNATE AS WELL, THE OFFICERS AUTHORIZED TO EXECUTE ON THE CORPORATION'S BEHALF. AL NOTE: IF THIS COMPANY IS REQUESTED TO DISBURSE FUNDS IN CONNECTION WITH PPELIMSC 9123/93Ex Pagc 8 Ordcr NO: 7338278 U52 SCHEDULE B (continued) Your Ref. MAPPING OF LOT 6 THIS TRANSACTION, CHAPTER 598, STATUTES OF 1989 MANDATES HOLD PERIODS FOR CHECKS DEPOSITED TO ESCROW OR SUB- ESCROW ACCOUNTS. THE MANDATORY HOLD PERIOD FOR CASHIER'S CHECKS, CERTIFIED CHECKS AND TELLER'S CHECKS IS ONE BUSINESS DAY AFTER THE DAY DEPOSITED. OTHER CHECKS REQUIRE A HOLD PERIOD FROM THREE TO SEVEN BUSINESS DAYS AFTER THE DAY DEPOSITED. NOTE: ANY FUNDING WIRES TO CHICAGO TITLE COMPANY ARE TO BE DIRECTED AS FOLLOWS: BANK OF AMERICA 1850 GATEWAY BOULEVARD CONCORD. CALIFORNIA ABA 121 - 000358 CREDIT TO CHICAGO TITLE SUB- ESCROW DEPOSITORY ACCOUNT NO. 12359 -50752 FURTHER CREDIT TO ORDER NO: 007338278 ATTN: KEN BROWN TITLE OFFICER AM DP PRELIMBC 9 /23Mbk aRA"NiC SCALE a IN 2w Sw Ma PM 17446 PAR 4 I n 4 x§/ s� d��a N ntYV. W n tatJ'..i• •V.IY PRIVATE ROAD NO MI- CITY OF ENCINITAS TRACT 93 -029 M•/R M.al K A R 11A/1IA� M •6DIOINS /rM MY/fC Ryy u<urrLN.wrt .p4Knr MCafi`m rrna K oaL Ya /Y%N, /1 W M •Rppwtl wM I1v R ro•a ..w'R9NYL NC fAf1 fn.9v! r A[Cagw )/PM AL 0aC M. r %S•OrINi< Ml ? dl0u /Cara) 11x\{1 ? R M Rf0�f11' O ML a[l6i[R m IFMar FAM.YIL Kff# u✓ / m [.ar wr owsw n m N.V. i MAP • ,i LOT 7 �xl 12S 1 6 ` \yt L 9i.. <s..s r �L.•l L. sla•a �.. 1)f•<f Iola u,as \ i ••I R . laJOw�L %• )17.70' prwv m xl ��CN1"aI�TZM SC +[� =� M �yJ MAP NO. PM\ 12413 I A.L7Y�0 ` l _x1 A. /0 is '' \ \ ' T• % \ 1 N IxtYM.-'1W 1 ,� /% 1 IIYiI•L< I `/\ L w71 r. a Nw.rt sia. r, weaNmal BoLIN0AR7 As.YJ. � : a.Ir LIiHII ; RoS. 14175 J P[ A L L01,C5R I '•r•r Oa G \ LOT 6 1 ? 13 "� / N'Y� 13.11 AC NET a 00 "E �p551: \\\ N �SLID 13.71 AC CRO33 I Y�VF\ \ T "LC• ORTION LOT 16 SOS •Thh ale h fa vas Atl b 1/aW )% LiMw'V. f k Slltil In,a .xN reiermce N a0tep •vd e11,r a - LAS ENCIN/TAS nCOlrflm 7203/71 "I" fC 1 wpm 000' "M.AIAa Pf Y s MAP 848 S CMIAtMC Ol Lae' EA=l ra RrOrG nMAL nAA, MIOYr rr9 eL [•uKNt Ie ou9[Lf usL[vyaN. Ipt poa IN. 1-0371% a0G `12 Ss1- Otor%1 ACCON[o sa/1' rae LALCt ANa PIC NIr. /N W, f ArsmeLV IOJ ar A« aPM Y.C[ CAYIcxi ro s ¢NrtWK V taw' [•XNMi IW %•- 1tt•311. I[C..n 11/11 stY.L A/MO\'AL a• A uortolNCN. AM001' no x.101 IUI.OUs rn r3 1r r,s r m to c A C m IatL —ts LRANCHO R 3 PM17377 m .0. n1013- wtt[53 I :rYr.•.V'RIwCT q cx N0. 11X71 . fuIHI T 11 O .•'a[A rt A RtT t' A 21. 0 of eal M "AM as0 <y/ </ 0 /.- I o NCGxrtr . sF7 3/. 11 Oar L M a.•# ar3[ sr.Mm Li .X8 11,10` [ p wau:[t 111X1 Na T 4 .["m W t T. N wM A )b[A' VM Ir/L "I LS all 171a'w• R .J LIaL# oRTIP'sr Amna \ III II ` \�\ *a4�• \`'f 1\: N'Y� 1i a 00 "E �p551: \\\ aa �Ls �SLID r EN il•1i y 6A�I W%1 ar OP. Y�VF\ \ T "LC• t •CCrS.T .r .v0 m LWC txaf II}V ` 1.0 C NElg •isw. " s¢slar <� i "C �_�,t "RY xiV <I rli 1.� aDl'AgOi Cr Ny 1) }i� I\SaN ,30111 rLw �SLID r EN il•1i y 6A�I W%1 ar OP. T "LC• t •CCrS.T .r .v0 m LWC txaf II}V SOS •Thh ale h fa vas Atl b 1/aW )% LiMw'V. f k Slltil In,a .xN reiermce N a0tep •vd e11,r 3 M' M1`CLMC r•unMf m aUH. NMnW4 Ioo Mr1Ki Kn OrC /10. ll -t%3 /r Nr. Nyk Dm abi . 1.1,1..2120 b m rN_ a.- (a,nr,20� a•.�.. -. m LlbJar 1 [a a%p e1 oralullw roe 1010.1 rL9.osrs _ _ _ _- __ I I" fAmIlrnr rM Kay.r Iylws[s - ra r•xN:nr r A% Rw..I eNr•eus IV aOC a 11 -orwox R<eMUO •20201 erg o 9LCa.a0 vn/61 As okS no. r•Ct..ao rN IAIC4 NY 12077 I tt' 11VA1110AD V11 1Tr W%1 ar OP. Ip MC x0. /1- 11)120• ICCOecrn •/1/201 t •CCrS.T .r .v0 m LWC txaf II}V 11 rAXKNr m S.a C a L roe PDX$ Ana %1AT. a AAv NCjC% •na tmtss 3 M' M1`CLMC r•unMf m aUH. NMnW4 Ioo Mr1Ki Kn OrC /10. ll -t%3 /r "Mn Rot• - ICW PECPo K91 paa rp. Ls -OJJ%1 RCCO.OLa runs YslaOrrra•L nCOlrflm 7203/71 "I" fC 1 wpm 000' "M.AIAa Pf Y s r 3S 07iT ar a@Y•rraM 101 1.ar1•r OV00=5 S CMIAtMC Ol Lae' EA=l ra RrOrG nMAL nAA, MIOYr rr9 eL [•uKNt Ie ou9[Lf usL[vyaN. Ipt poa IN. 1-0371% a0G `12 Ss1- Otor%1 ACCON[o sa/1' rae LALCt ANa PIC NIr. /N W, f ArsmeLV IOJ ar A« aPM Y.C[ CAYIcxi ro s ¢NrtWK V taw' [•XNMi IW %•- 1tt•311. I[C..n 11/11 stY.L A/MO\'AL a• A uortolNCN. AM001' no x.101 IUI.OUs rn r3 1r r,s r m to c A C m IatL —ts a0C r0_ei 20»33 irnCwr iris attMn3 M•e m .0. n1013- wtt[53 I :rYr.•.V'RIwCT q cx N0. 11X71 . CONWAY k ASSOCIATES, INC. 1.13 LI1t/1A0OL DRIVE C.RDirf- Rr- rNE -r_A, CA 12007 LL 13320 sLAR;;crx_ n A- I_Pmr st i_ __ Y. vLl CITY OF ENCINTAS TM 93 -029 SHEET 7 OF 4 &jEEM r E<XWD • 9gK.41 A IaIM )/•• Par ML .,,� aK Lf KI) p Iu 17311, aR At .1 • MaGns A /p94 )n' won ML Ahl asc &S' Li MI)A wpf u17) -Aiw II 17)20 Ilw Axa NY 12011 "I" fC 1 wpm ..If Rail, •< 4LSo u[ I ors 120 r1 w'acARS A ILN.D 1/i war /'K A,.' Pf N Ls ) IV A e1 f 10171 Kso Y[ I .1 S AIn YID Po 20)20 r' Q Warwrrs . SCr si•noAIt u -10 P.CCr fuIHI T 11 O .•'a[A rt A RtT t' A 21. 0 of eal M "AM as0 <y/ </ 0 /.- I o NCGxrtr . sF7 3/. 11 Oar L M a.•# ar3[ sr.Mm Li .X8 [ p wau:[t 111X1 Na T 4 .["m is wM A )b[A' VM Ir/L "I LS all ,1 f P=ans OAT. H9 Iu .1317 LIaL# oRTIP'sr Amna iY O xCwm SwH. DAM M "I. .R ,1111 •.KAlrf ALC[ss Warn er Ya ro 104 .uat /OA0 RLIMUS cv IA%4 NM 797 .\C - C{K•m nONAof [.1X2011 1,3 of .IAC[ LASCK.n ((111..71 [KCr s[[ v.[L" 1p ` WE s.rrr . \ LOT 1, SEC 8 T 1 35, R31y SErn sLAR;;crx_ n A- I_Pmr st i_ __ Y. vLl CITY OF ENCINTAS TM 93 -029 CUSTUM SHVICE NU. UOy"""ar. L/b� ' -RECORDING REQUES BY CHICAGO TITLE COMPANY DEC # 1997- 03Z37�4 AND WHEN RECORDED MAIL TO 09—JUL-1997 9 �4 Pm rcHRls D. MYERS 4505 CAMPOBELLO STREET OFFICIAL RECORDS T rf SAN DIEGO, CA 91130 1326 SAN DIEGO COUNTY RECORDER'S OFFICE GREGORY SMITH, COUNTY RECORDER RF= 9,00 FEES: 222.50 AF: 9100 DC AFt 1.00 L _j TAR- 203,50 El Crew No. Ha501' -N61 (i /, {� Ww & x t TY9 tNE FOR RE..OROERS USE A.P.N. 264- 240 -9Q -00 6iANT DEED THE UNDERS UNBE) ORANTOR(S) D S) DOCUMENTARY TRAMPERTAX R 7,0-3,5b C3 wmaxporuM uea ❑ Ctryd ENCINITAS ® romputtd on Ve fuL slue d tae iatexat or paepeAy coevged, or u ❑ compw<sd on the LuLL value iKa the .glue d Item or wcvmhranae rcmalai� at Ouc d ask, rnd FOR A VALUABLE CONSIDERATION t receipt of which is hereby a6maaledgcd CHRISTOPHER S. LLOYD, a married man as his sole and separate orooerty. and GREGORY CLEARY, a married man as his sole and separate bereby GRANT(S) to CHRIS D. MYERS , an unmarried man the following described real property in the County of SAN DIEGO , State of California: LEGAL DESCRIPTION ATTACHED HERETO AND MADE A PART HEREOF AS EXHIBIT ** THIS DEED IS BEING EXECUTED IN COUNTERPART ** Dated November 18, 1996 ^�) CHRIMP ER S. LTYD halos rtr, STATE OF T a Notary ruone In ano for Ulu younry ...+o,.,., v�«+•+ vw��• v I A14 I —� personeW blown tC rM (a Proved to ma on 01'r6sis of eatletactM Widence) to be the pen.on(e) whoss ra a(e) la /" aubaCAbad to the wdhin instwment and aeknowtatlged to me that he /eh*Ahey axaeutad the Same In hi►/hor/Weir UAhorirAd cepooky9la), and shat by his/her/614k signeturo(s) on the InatmMOM the pareen(a). Of "entity upon bMatf Of which the Paraon(s) acted, axaeumd WA etatrumaQL �{ NSSS� nry � antl ofaolM apt. � 1 9 WE ��1 I 1 ynaet4b/ary ' MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE: A' . L�km FOR MOr 1114 M stuv IF NO PARTY SO SHOWN, MILL. AS DIRECTED ABOVE Nam tiow Addraae City, State a. Dp W1 -10031 ebv 'FEB. 2, ly'Jd' '1 _.. MIUMH SJERVM tw. 009xeevnr. j RECORDING REQUE ) BY CHICAGO TITLE COMPANY rAND WHEN RECORDCI) MAIL TO CHRIS D. MYERS 1 9 9 ry 4505 CAMPOBELLO STREET i 3 2 1 SAN DIEGO. CA 92170 L J Escrow No. 4046037 -1147 Order No. 4eason - arwus aepea 7113 {af IOIS PaOplwRf tus THE UNDERSIGNED OR NTOR(S) DECIARBM DOCUMENTARYTRANSFERTAXLS $201.50 Ej w--orporated area ❑ Otyof ENCINITAS ® cwnputed on the foll7alut of tln inapt or property aonnyed, or lT ❑ Comyuted an the fall value foes dte value of *w or aotvmbrwtcn rameimng m time of NK and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, CIRISTOPHER S. LLOYD, a married roan as his sole and separate property, and GREGORY CLEARI, a married man as his sole and esparate property hereby ORANT(S) to CHRIS D. MYERS , an unmarried man the following described real property in the County Of SAN DIEGO , State of California: LEGAL DESCRIPTION ATTACHED HERETO AND MADE A PART HEREOF AS EXHIBIT "A ". 4* THIS DEED IS BEING EXECUTED IN COUNTERFARI *R Dated November 19, 1996 STATE OF COUNTY t On _ _ Cr '—") 55. CHRISTOPHER S. LLOYD belore me, peraocaly to me (0r 10� me on the but& 01 sabOactoN endenw W the person(s) wMose rtarne(s) is /are Subscribed to the within ' wet and ad kWged to me that he /sha/they aaecuted the same In hle/hw/dtetr authwised capemtyow), and that by hie /hw/thefr slynsture(s) on the instrument the pefaon4 . or the entity upon behalf of whlM the panon(aJ sorted, arcecuted ere irrtr.me� /��, V41TNESS my hand wri ofedat riot. r . ji ii1AA"����]►►G"�11`�ypt' \} 9lpnsture 01 homity X07 /lJV\. MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE m� _tolvlwr FDA tUT.VW acu M Vsue IF NO PARTY SO SHOWri MAIL AS DIRECTED ABOVE Nwne Street Adana qty, State a Lp �FEB. L 1998■ 9:06Ab1�CTC CUSTUMER SERVICE U. U4�f. vuo L, STATE OF CALIFORNIA County of San Diego 1328 On December 3,1996, before me, Don Reed, personally appeared Gregory Cleary, personally known to me (or proved to me on the basis of satisfactory evidence) to be the person whose name is subscribed to the within instrument and acknowledgment to me that he executed the same in his authorized capacity, and that by hcr signature on the instrument the person, or entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. 44 42�1 Notary's Signature �u5lumiK JhH M V. u4J uio�++ • t Qr4Or• NO.- 999674 DESCRIPTION PARCEL A: 1329 LOT 5 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B� AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES OVeR, UNDER, ALONG AND ACROSS THAT PORTION OF SAID MAP NO. 13320, DESIGNATED AND DELINEATED THEREON AS "PROPOSED PRIVATE STREET EASEMENT, EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT S. PARCEL C: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL. AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION B, TOWNSHIP 13 SOUTH, RANOBt3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE .LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY 09 SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MA9 THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1898, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LOD? 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET; THENCE NORTH 2 025'09" WEST 41S.03 FEET; THENCE NORTH 2 025'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25. 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON - TANGENT 510.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67 043'39• PAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01024'260 A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING; THENCE SOUTH 69 108'08^ WEST 666.33 PEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY TM OUGB A CENTRAL ANGLE OF 22 °07'07• A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EKRIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OT SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVEENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01.15'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A. SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLTVENU910 MUNICIPAL WATER DISTRICT, A 1 `F6B. [. ly9tl" y:U'IAdt "" 61u �Ualua�cx ae�triUn ov. U0y f. Uiu NO i 999674 DESCRIMON 1330 DISTANCE OF 73.19 FEET TO A POINT ON TIE BEGINNING OF A NON - TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH SEARS NORTH 05 '01'36" FAST; TEENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25.53'28" A DISTANCE OF 451.16 PEST; THMCE TANGENT TO SAID CURVE NORTH 69 608'08" EAST, 665.43 FEET TO THE CENTER LINE 08 SAID COUNTY ROAD SURVEY NO. 551 (LONE JACK ROAD) BEING A POINT ON THE ARC OF SAID NON- TANOENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72.21'11" E AST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03.13'05" A DISTANCE OF 32.01 FRET TO THE TRUE POINT OF MEGINNIN6. EXCEPTING THEREFROM THAT PORTION LYING WITHIN TAT 5 OF NAP 13320. 2 CHICAGO TI I L,E COMPANY Issuing Office: 925 "B" STREET SAN DIEGO, CA 92101 PHONE NO. (619) 239 -6081 FAX NO. (619) 544 -6277 JANET MCCOLLOUGH COLDWELL BANKER 285 N. EL CAMINO REAL STE.101 ENCINITAS, CA 92024 Dalcd as of: February 14, 1997 at 7: 30 AM jq- RE: DEVELOPMENT PLANNING CONSULTANTS Order No. 7338034 U52 Reference: ESC. NO 7871984 -N67 Regarding: LOT 29, PORTION OF APN 264 - 240 -30 ENCINITAS. CA 92024 In response to the above referenced application for a policy of title insurance, CHICAGO TITLE COMPANY hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Politics of Title Insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception in Schedule B or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage of said Policy or Policies are set forth in the attached list. Copies of the Policy forms should be read. They arc available from the office which issued the report. Please read the exceptions shown or referred to in Schedule B and the exceptions and exclusions set forth in the attached list of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. THIS REPORT (AND ANY SUPPLEMENTS OR AMENDMENTS HERETO) IS ISSUED SOLELY FOR THE PURPOSE OF FACILITATING THE ISSUANCE OF A POLICY OF TITLE INSURANCE AND NO LIABILITY 1S ASSUMED HEREBY. IF IT IS DESIRED THAT LIABILITY BE ASSUMED PRIOR TO THE ISSUANCE OF A POLICY OFTITLE INSURANCE, A BINDER OR COMMITMENT SHOULD BE REQUESTED. The form of policy of title insurance contemplated by this report is: CALIFORNIA LAND TITLE ASSOCIATION STANDARD COVERAGE POLICY L1.9✓ KEN B OWN Title Officer vsyse -11 /or /u m SCHEDULE A Ordcr No: 7338034 U52 Your Ref: ESC. NO 7871984 -N67 1. The estate or interest in the land hereinafter described or referred to covered by this report is: FEE AND EASEMENT 2. Title to said estate or interest at the date hereof is vested in: CHRISTOPHER S. LLOYD, a married man as his sole and separate property, SUBJECT TO PROCEEDINGS PENDING IN THE BANKRUPTCY COURT WHERE A PETITION FOR RELIEF WAS FILED. NAME OF DEBTOR: DATE OF FILING: U.S. DISTRICT COURT: CASE NO: CHRISTOPHER STEVEN LLOYD OCTOBER 2, 1996 9613475 AND GREGORY CLEARY, a married man as his sole and separate property, AS THEIR RESPECTIVE INTERESTS APPEAR OF RECORD 3. The land referred to in this report is situated in the State of California, County of SAN DIEGO and is described as follows: SEE ATTACHED DESCRIPTION Order NO: 7338034 U52 DESCRIPTION PARCEL A: LOT 6 OF CITY OF ENCINITAS TRACT 93 -029, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 13320, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON MAY 10, 1996. PARCEL B: AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER, UNDER, ALONG AND ACROSS ALL THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 27, 1898, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET; THENCE NORTH 2 °25'09" WEST 475.03 FEET; THENCE NORTH 2 025'19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 266591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTER LINE OF COUNTY ROAD SURVEY NO. 554 (KNOWN AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON - TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67 °43'39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 01 024'26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTER LINE OF SAID ROAD SURVEY 554; SAID POINT BEING THE TRUE POINT OF BEGINNING; THENCE SOUTH 69008'08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 °07'07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A, SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A RADIAL LINE OF WHICH BEARS NORTH 01 °15'15" WEST; THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A, SAID LINE ALSO BEING THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON- TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OF WHICH BEARS NORTH 05 001'36" EAST; THENCE EASTERLY ALONG SAID 1016.00 FOOT RADIUS CURVE CONCAVE THRU A CENTRAL ANGLE OF 25053'2B" A DISTANCE OF 459.16 FEET; THENCE TANGENT TO SAID CURVE NORTH 69 008'08" EAST, 665.43 FEET TO THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONE JACK ROAD) BEING A POINT ON THE ARC OF SAID NON- TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 72 021'11" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03 °13'05" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM THAT PORTION LYING WITHIN LOT 6 OF MAP 13320. 1 SCHEDULE B Page 1 Order No: 7338034 U52 Your Ref: ESC. NO 7871984 -N67 At the dale hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in the policy form designated on the face page of this Report would be as follows: A 1. PROPERTY TAXES, INCLUDING ANY ASSESSMENTS COLLECTED WITH TAXES, TO BE LEVIED FOR THE FISCAL YEAR 1997 -98 THAT ARE A LIEN NOT YET DUE. AU 2. PROPERTY TAXES, INCLUDING ANY PERSONAL PROPERTY TAXES AND ANY ASSESSMENTS COLLECTED WITH TAXES, FOR THE FISCAL YEAR 1996 -1997. 1ST INSTALLMENT: $3,756.74 PENALTY: $375.67 (DUE AFTER DECEMBER 10) 2ND INSTALLMENT: $3,756.74 PENALTY AND COST: $385.67 (DUE AFTER APRIL 10) HOMEOWNERS EXEMPTION: $NONE CODE AREA: 19073 ASSESSMENT NO: 264- 240 -30 -00 a 3. THE LIEN OF SUPPLEMENTAL OR ESCAPED ASSESSMENTS OF PROPERTY TAXES, IF ANY, MADE PURSUANT TO THE PROVISIONS OF PART 0.5, CHAPTER 3.5 OR PART 2, CHAPTER 3, ARTICLES 3 AND 4 RESPECTIVELY (COMMENCING WITH SECTION 75) OF THE REVENUE AND TAXATION CODE OF THE STATE OF CALIFORNIA AS A RESULT OF THE TRANSFER OF TITLE TO THE VESTEE NAMED IN SCHEDULE A; OR AS A RESULT OF CHANGES IN OWNERSHIP OR NEW CONSTRUCTION OCCURRING PRIOR TO DATE OF POLICY. C 4. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT GRANTED TO: OLIVENHAIN MUNICIPAL WATER DISTRICT PURPOSE: A PIPELINE OR PIPELINES FOR ANY AND ALL PURPOSES, TOGETHER WITH THEIR NECESSARY FIXTURES AND APPURTENANCES INCLUDING BUT NOT LIMITED TO FACILITIES FOR POWER TRANSMISSION AND COMMUNICATION PURPOSES RECORDED: JULY 25, 1977 AS FILE NO. 77- 296591, OFFICIAL RECORDS AFFECTS: THE ROUTE AFFECTS A PORTION OF SAID LOT 6 OF SAID LAND AS MORE FULLY DESCRIBED IN SAID DOCUMENT CONSENT OF EXCLUSIVE EASEMENT HOLDER, THE OLIVENHAIN MUNICIPAL WATER DISTRICT RECORDED MAY 24, 1994 AS FILE NO. 1994 - 0340003 FOR A GRANT OF EASEMENT TO PACIFIC BELL. D 5. AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: SEPTEMBER 6, 1990 BY AND BETWEEN: CHRISTOPHER S. LLOYD rr Um" /71e1.n< Page 2 Order No: 7338034 U52 SCHEDULE B (continued) Your Ref: ESC. NO 7871984 -N67 RECORDED: NOVEMBER 20, 1990 , AS FILE NO. 90- 0624192 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. AG 6. A COVENANT AND AGREEMENT EXECUTED BY: BARRATT AMERICAN INCORPORATED, IN FAVOR OF: CHRISTOPHER S. LLOYD, RECORDED: FEBRUARY 25, 1991 AS FILE NO. 1991- 0081600 OF OFFICIAL RECORDS, WHICH, AMONG OTHER THINGS, PROVIDES: IMPROVEMENT OF LONE JACK ROAD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. E 7. AN IRREVOCABLE OFFER TO DEDICATE REAL PROPERTY RECORDED APRIL 2, 1991 AS FILE NO. 1991 - 0146056, OFFICIAL RECORDS, WHEREIN A PORTION OF SAID LAND WAS OFFERED FOR DEDICATION TO PUBLIC USE FOR PUBLIC ROAD AND INCIDENTAL PURPOSES. AFFECTS: AS SHOWN ON SAID MAP NO. 13320 F SAID INSTRUMENT ADDITIONALLY CONTAINS THE PRIVILEGE AND RIGHT TO EXTEND DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SLOPES BEYOND THE LIMITS OF THE ABOVE DESCRIBED RIGHT OF WAY WHERE REQUIRED FOR THE CONSTRUCTION AND MAINTENANCE THEREOF. G 8. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT PURPOSE: ROAD AND UTILITY RECORDED: APRIL 19, 1991 AS FILE NO. 1991- 0178724, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. i+ SAID DOCUMENT RECITES IN PART AS FOLLOWS: SAID INSTRUMENT ADDITIONALLY GRANTS THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SOPES AND DRAINAGE FOR THE BENEFIT OF SAID EASEMENT OVER A PORTION OF THE REAL PROPERTY DESCRIBED THEREIN. r AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN ON MAP OF TRACT NO. 12816. EASEMENT PURPOSE: PROPOSED PRIVATE ROAD AFFECTS: AS SHOWN ON SAID MAP EASEMENT Pagc 3 Ordcr No: 7338034 U52 SCHEDULE B (continued) Your Rd. ESC. NO 7871984 -N67 PURPOSE: WATER PIPELINES, OTHER DISTRICT FACILITIES AND ALL ACCESS PURPOSES AFFECTS: AS SHOWN ON SAID MAP m 10. COVENANTS, CONDITIONS AND RESTRICTIONS (DELETING THEREFROM ANY RESTRICTIONS BASED ON RACE, COLOR OR CREED) AS SET FORTH IN THE DOCUMENT RECORDED: MARCH 27, 1992 AS FILE NO. 1992- 0175473, OFFICIAL REC Al SAID COVENANTS, CONDITIONS AND RESTRICTIONS PROVIDE THAT A VIOLATION THEREOF SHALL NOT DEFEAT THE LIEN OF ANY MORTGAGE OR DEED OF TRUST MADE IN GOOD FAITH AND FOR VALUE. ✓ 11 AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: MARCH 25, 1992 BY AND BETWEEN: CHRISTOPHER S. LLOYD, GREGORY CLEARY AND CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITA Z. LLOYD DATED SEPTEMBER 11, 1980 RECORDED: MARCH 27, 1992 , AS FILE NO. 1992- 0175474 OF OFFICIAL RECORDS REGARDING: PRIVATE ROAD MAINTENANCE & COST SHARING REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. K 1a2. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT PURPOSE: INGRESS AND EGRESS, ROAD AND UTILITIES AS GRANTED /RESERVED BY VARIOUS INSTRUMENTS OF RECORD, ONE OF WHICH RECORDED MARCH 27, 1992 AS FILE NO. 1992- 0175477, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. 13. A DEED OF TRUST TO SECURE AN INDEBTEDNESS IN THE AMOUNT SHOWN BELOW, AND ANY OTHER OBLIGATIONS SECURED THEREBY AMOUNT: $300,000.00 DATED: APRIL 28, 1993 TRUSTOR: CHRISTOPHER S. LLOYD, A MARRIED MAN, CHRISTOPHER S. LLOYD AS TRUSTEE OF THE GREGORY TRUST UNDER WILL OF MARGARITA Z. LLOYD DATED 9/11/80 AND GREGORY J. CLEARY TRUSTEE: COMMONWEALTH LAND TITLE COMPANY, A CALIFORNIA CORPORATION BENEFICIARY: JOSEPH DE LA VARA AND GLORIA DE LA VARA, HUSBAND AND P LIMW 9 /n /WJ Pagc 4 SCHEDULE B (continued) Ordcr No: 7338034 U52 Your Rc[: ESC. NO 7871984 -N67 WIFE AS JOINT TENANTS RECORDED: APRIL 28, 1993 AS FILE NO. 1993- 0261336, OFFICIAL RECORDS AFFECTS THE HEREIN DESCRIBED LAND AND OTHER LAND. NOTE: IF THIS ITEM IS TO BE ELIMINATED FROM OUR POLICY OF TITLE INSURANCE, WHEN Z<b ISSUED, WE WILL REQUIRE THE FOLLOWING 48 HOURS PRIOR TO THE CLOSE OF O ESCROW: i G� (1) ORIGINAL NOTE (2) ORIGINAL DEED OF TRUST A (3) SIGNED REQUEST FOR FULL RECONVEYANCE IF THE ORIGINAL NOTE OR ORIGINAL DEED OF TRUST ARE LOST PLEASE CONTACT YOUR TITLE OFFICER AS SOON AS POSSIBLE FOR OUR REQUIREMENTS. IF THE BENEFICIARY UNDER SAID ^.HOVE- MENTIONED DEED OF TRUST IS A TRUST THEN THE FOLLOWING ADDITIONAL ITEMS WILL BE REQUIRED: (1) A COPY OF THE TRUST INSTRUMENT CREATING THE TRUST REFERENCED IN SAID DOCUMENT AND ALL AMENDMENTS THERETO (2) A WRITTEN VERIFICATION BY ALL PRESENT TRUSTEES THAT THE COPY IS A TRUE AND CORRECT COPY OF THE TRUST, AS IT MAY HAVE BEEN AMENDED, THAT IT IS IN FULL FORCE AND EFFECT AND THAT IT HAS NOT BEEN REVOKED OR TERMINATED. IF A DEMAND IS SUBMITTED BY AN AGENT OF THE BENEFICIARY, AND THAT DEMAND IS LESS THAN THE AMOUNT OWED PURSUANT TO THE TERMS OF THE PROMISSORY NOTE, IN ADDITION TO THOSE ITEMS DESCRIBED ABOVE, WE WILL ALSO REQUIRE A WRITTEN STATEMENT FROM THE BENEFICIARY STATING THAT THEIR AGENT IS AUTHORIZED TO SUBMIT A DEMAND FOR LESS THAN IS OWED BY THE BORROWER. w AN ASSIGNMENT OF THE BENEFICIAL INTEREST UNDER SAID DEED OF TRUST WHICH NAMES ,'NIW VjTj /K101, AS ASSIGNEE: DAVID HANDLER AND CLAIRE E. HANDLER, CO- TRUSTEES OF THE D & C FAMILY TRUST UTD OCTOBER 21, 1982, AS TO AN UNDIVIDED FIFTY PERCENT (504) INTEREST, AND GERALD HANDLER AND JUDITH HANDLER, TRUSTEES OF THE HANDLER TRUST UTD MARCH 4, 1985, AS TO AN UNDIVIDED FIFTY (504) INTEREST r' RECORDED: AUGUST 15, 1996 AS FILE NO. 1996- 0416900, OFFICIAL RECORDS f �v AN AGREEMENT, AND THE TERMS AND CONDITIONS AS CONTAINED THEREIN DATED: MAY 7, 1993 ,'NIW VjTj /K101, Page 5 Order No: 7338034 U52 SCHEDULE B (continued) Your Ref: ESC. NO 7871984 -N67 BY AND BETWEEN: OLIVENHAIN MUNICIPAL WATER DISTRICT, A MUNICIPAL WATER DISTRICT AND CHRIS LLOYD RECORDED: MAY 18, 1993 AS FILE NO. 1993 - 0312187 OF OFFICIAL RECORDS REGARDING: AGREEMENT TO PROVIDE WATER SERVICE REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. AR 15. A COVENANT AND AGREEMENT EXECUTED BY: CHRISTOPHER LLOYD, TRUSTEE IN FAVOR OF: CITY OF ENCINITAS RECORDED: AUGUST 27, 1993 AS FILE NO. 1993 - 0563741, OFFICIAL RECORDS WHICH AMONG OTHER THINGS PROVIDES: A. PARK FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL SUM (78,409.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR FINAL PARCEL MAP #92 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($2,803.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. B. TRAFFIC FEES FOR THE DEVELOPMENT SHALL BE PRORATED EQUALLY OF 1 /3RD THE TOTAL 'SUM ($2,703.00) FOR PARCELS 1 THROUGH 3, INCLUSIVE FOR MAP #92 -212. EACH PARCEL SHALL PAY THE PRORATED FEE ($901.00 / PARCEL) PRIOR TO ISSUANCE OF A BUILDING PERMIT. 0 16. A COVENANT AND AGREEMENT EXECUTED BY: CHRISTOPHER S. LLOYD, TRUSTEE AND GREGORY CLEARY IN FAVOR OF: CITY OF ENCINITAS RECORDED: OCTOBER 20, 1993 AS FILE NO. 1993 - 0700454, OFFICIAL RECORDS WHICH AMONG OTHER THINGS PROVIDES FLOOD CONTROL FEE SHALL BE ASSESSED AND COLLECTED DURING THE BUILDING PERMIT PROCESSING PRIOR TO THE CONSTRUCTION OF ANY IMPERVIOUS SURFACE r 17. COVENANT REGARDING REAL PROPERTY AND INDEMNIFICATION AGREEMENT BY AND BETWEEN CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITY Z. LLOYD DATED SEPTEMBER 11, 1980; CHRISTOPHER S. LLOYD, a married man as his sole and separate property; AND GREGORY CLEARY, a married man as his sole and separate property, AND EUGENE AND BARBARA HIRSCHKOFF RECORDEDPECEMBERI '2, 1993 AS FILE NO. 1993 - 0812962, OFFICIAL RECORDS. P oZ) _ ,1 /f V REFERENCE IS MADE TO SAID DOCUMENT FOR F� PARTICULARS. a 18. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS v uuecclnl� SCHEDULE B Pagc 6 (continued) Ordcr No: 7338034 U52 Your Rd: ESC. NO 7871984 -N67 SET FORTH IN A DOCUMENT GRANTED TO PURPOSE: RECORDED: AFFECTS: DANIELS CABLEVISION INC. CABLE TELEVISION SYSTEM AND ACCESS APRIL 5, 1994 AS FILE NO. 1994 - 0224539, OFFICIAL RDS (TE EXAC T LOCATION AND EXTENT OF SAID EASEMENT IS NOT LOSED OF RECORD. REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. s 19. A TAX LIEN FOR THE AMOUNT SHOWN AND ANY OTHER AMOUNTS DUE, IN FAVOR OF THE UNITED STATES OF AMERICA, ASSESSED BY THE DISTRICT DIRECTOR OF INTERNAL REVENUE. llt�. FEDERAL SERIAL NO.: 3301 -6992 •y�� TAXPAYER: CHRISTOPHER LLOYD AMOUNT: $390,494.08 bbS RECORDED: MARCH 18, 1996 AS FILE NO. 1996 - 0132504, OFFICIAL RECORDS AL AN AGREEMENT WHICH STATES THAT THIS INSTRUMENT WAS SUBORDINATED TO: A DEED OF TRUST RECORDED: APRIL 28, 1993 AS FILE NO. 1993- 261336 OF OFFICIAL RECORDS BY AGREEMENT RECORDED: AUGUST 15, 1996 AS FILE NO. 1996 - 0416901 OF OFFICIAL RECORDS r 20. A CLAIM OF MECHANIC'S LIEN n.,i AMOUNT: $38,882.00 CLAIMANT: FRASER ENGINEERING, INC. RECORDED: APRIL 4, 1996 AS FILE NO. 1996 - 0168655, OFFICIAL RECORDS EXTENSION OF TIME RECORDED OCTOBER 4, 1996 AS FILE NO. 1996 - 0505425 OF OFFICIAL RECORDS. U 21. EASEMENTS FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SHOWN OR AS OFFERED FOR DEDICATION ON THE RECORDED MAP SHOWN BELOW. MAP OF: TRACT NO. 13320 Pagc 7 SCHEDULE B (continued) Ordcr No: 7338034 U52 Your Rd. ESC. NO 7871984 -N67 EASEMENT PURPOSE: PROPOSED PRIVATE STREET AFFECTS: AS SHOWN THEREON v 22. ANY EASEMENT OR OTHER RIGHTS WHICH MAY EXIST OVER SAID LAND, AS DISCLOSED ON A COPY OF THE MAP OF TRACT NO. 13320 FILED IN THE OFFICE OF THE COUNTY ROAD COMMISSIONER AND REFERRED TO IN THE DEDICATION CLAUSE OF THE RECORDED MAP OF SAID TRACT. w 23. A COVENANT AND AGREEMENT UPON AND SUBJECT TO THE TERMS AND CONDITIONS THEREIN EXECUTED BY: CHRISTOPHER S. LLOYD AND GREGORY CLEARY IN FAVOR OF: THE CITY OF ENCINITAS RECORDED: APRIL 25, 1996 AS FILE NO. 1996- 0207397, OFFICIAL RECORDS REFERENCE IS MADE TO SAID DOCUMENT FOR FULL PARTICULARS. x THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. �r 24'. A DOCUMENT ENTITLED "LIEN COVENANT REGARDING REAL PROPERTY: IMPROVEMENTS REQUIRED AS CONDITION ON FINAL APPROVAL OF SUBDIVISION OF REAL PROPERTY ", DATED MARCH 28, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CLEARY,� SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN CONTAINED, Q RECORDED APRIL 25, 1996 AS FILE NO. 1996 - 0207398, OFFICIAL RECORDS. / Y'Y z THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES Q 3 ITS TERMINATION. AA 111 25. A DOCUMENT ENTITLED "COVENANT REGARDING REAL PROPERTY WAIVER OF PROTEST TO ASSESSMENTS ", DATED MARCH 27, 1996 EXECUTED BY CHRISTOPHER S. LLOYD AND GREGORY CLEARY, SUBJECT TO ALL THE TERMS, PROVISIONS AND CONDITIONS THEREIN J CONTAINED, RECORDED APRIL 25, 1996 AS FILE NO. 1996 - 0207399, OFFICIAL 1 RECORDS 0"J "s ', 1 AD THIS COVENANT AND AGREEMENT SHALL RUN WITH THE LAND AND SHALL BE BINDING UPON ANY FUTURE OWNERS, ENCUMBRANCERS, THEIR SUCCESSORS, HEIRS OR ASSIGNS AND SHALL CONTINUE IN EFFECT UNTIL THE PROPER GOVERNMENT AGENCY APPROVES ITS TERMINATION. AC 26. AN EASEMENT FOR THE PURPOSE SHOWN BELOW AND RIGHTS INCIDENTAL THERETO AS SET FORTH IN A DOCUMENT v uMece /m /w Pagc 8 Ordcr No: 7338034 SCHEDULE B (continued) U52 Your Rcf: ESC. NO 7871984 -N67 GRANTED TO: OLIVENHAIN MUNICIPAL WATER DISTRICT, A PUBLIC AGENCY PURPOSE: PIPELINE OR PIPELINES AND APPURTENANCES, TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS RECORDED: APRIL 25, 1996 AS FILE NO. 1996 - 0207710, OFFICIAL RECORDS AFFECTS: THE ROUTE THEREOF AFFECTS A PORTION OF SAID LAND AND IS MORE FULLY DESCRIBED IN SAID DOCUMENT. AN 27. A CLAIM OF MECHANIC'S LIEN AMOUNT: $34,408.84 CLAIMANT: SIM J. HARRIS COMPANY RECORDED: AUGUST 9, 1996 AS FILE NO. 1996- 0405173 OF OFFICIAL RECORDS AO A NOTICE OF PENDING ACTION TO FORECLOSE SAID LIEN COUNTY: SAN DIEGO COURT: MUNICIPAL COURT, NORTH COUNTY JUDICIAL DISTRICT -.CASE NO.: N072656 RECORDED: OCTOBER 4, 1996 AS FILE NO. 1996 - 0506335, OFFICIAL RECORDS AP 28. A CLAIM OF MECHANIC'S LIEN AMOUNT: $111,722.04 CLAIMANT: LANE FUKUDA DBA LANE FUKUDA EXCAVATING RECORDED: AUGUST 21, 1996 AS FILE NO. 1996 - 0425497 OF OFFICIAL RECORDS Ap 29. A CLAIM OF MECHANIC'S LIEN AMOUNT: $89,000.00 CLAIMANT: CONWAY & ASSOCIATES, INC. RECORDED: AUGUST 27, 1996 AS FILE NO. 1996 - 0436250 OF OFFICIAL RECORDS Ae 30. A CLAIM OF MECHANIC'S LIEN AMOUNT: $7,525.00 CLAIMANT: CARDIFF DESIGN CENTER, INC. RECORDED: AUGUST 27, 1996 AS FILE NO. 1996 - 0436251 OF OFFICIAL RECORDS SCHEDULE B Page 9 (continued) Order No: 7338034 U52 Your Ref: ESC. NO 7871984 -N67 AS 31. A DEED OF TRUST TO SECURE AN INDEBTEDNESS IN THE ORIGINAL AMOUNT SHOWN BELOW AMOUNT: $6,000.00 DATED: SEPTEMBER 30, 1996 TRUSTOR: CHRISTOPHER S. LLOYD, A MARRIED MAN AS HIS SOLE AND SEPARATE PROPERTY AND GREGORY CLEARY, A MARRIED MAN AS HIS SOLE AND SEPARATE PROPERTY TRUSTEE: FIRST AMERICAN TITLE INSURANCE COMPANY, A CALIFORNIA CORPORATION BENEFICIARY: DENNIS HAUSWIRTH AS TO ONE HALF INTEREST, AND MARTY MC COMAS AND LYNN MC COMAS, HUSBAND AND WIFE, AS TO ONE HALF INTEREST RECORDED: OCTOBER 2, 1996 AS FILE NO. 1996 - 0501637, OFFICIAL RECORDS ORIGINAL LOAN NUMBER: AT 32. A CLAIM OF MECHANIC'S LIEN AMOUNT: $60,879.94 CLAIMANT: COAST GEOTECHNICAL RECORDED: OCTOBER 8, 1996 AS FILE NO. 1996- 0510133, OFFICIAL RECORDS AD END OF SCHEDULE B AE NOTE NO. 3: YOUR ORDER FOR TITLE WORK CALLS FOR A SEARCH OF PROPERTY THAT IS IDENTIFIED BY A STREET ADDRESS ONLY. BASED ON OUR RECORDS, WE BELIEVE THAT THE DESCRIPTION IN THIS REPORT COVERS THE PARCEL THAT YOU REQUESTED. HOWEVER, WE CAN GIVE NO ASSURANCE OF THIS. TO PREVENT ERRORS AND TO BE CERTAIN THAT THE PROPER PARCEL OF LAND WILL APPEAR ON THE DOCUMENTS AND ON THE POLICY OF TITLE INSURANCE, WE REQUIRE THAT WRITTEN APPROVAL OF THE LEGAL DESCRIPTION IN THIS REPORT BE SENT TO US, SIGNED BY THE ESCROW OFFICER OR BY THE PARTIES TO THE TRANSACTION. (CHRISTOPHER S. LLOYD AND GREGORY CLEARY) �IH 1227 RECORDING REQUEST BY AND WHEN RECORDED MAIL TO: + Daniels Cablevision 5770 E1 Camino Real Carlsbad, CA 92008 • Attn: Corporate Contracts + NO TAX DUE — no consideration paid DOCUMENYjAARRRYY TRANSFER TAX $ 0 BY FOR DOC # 1994-' x539 05 —APR -1994 _ =41 PM OFFICIAL RECORDS SAN DIEGO COUNTY RECORDER'S OFFICE I GREGORY SMITH, COUNTY RECORDER RF: 10.00 FEES: 12.00 AF: 10.00 MF: 2.00 CABLE TELEVISION CONSTRUCTION FIRING AGREEMENT AND EASEMENT THIS AGREEMENT is made and entered into this 15 day of March , 19 93 , by and between Daniels Cablevision Inc. (Company ") and RECITALS Chris Lloyd, aka Christopher d ( "Owner"). The Company holds a Franchise permit or other authority for, and owns and operate a cable television system within the City, town or county of Encinitas , and Owner owns the real property and improvements known as an Testa Tract 97 -41 and located slow v,T l,w +,A Ton, Tack ( "Development "), the legal description of which is attached hereto as Exhibit" "A" and incorporated herein by reference. WHEREAS, Owner desires to have cable television service available at the dwelling units of the Development and Company desires to provide such services to the dwelling units. NOW, THEREFORE, in consideration of the mutual covenants, conditions, and agreements, contained herein, and for other valuable consideration, the parties agree as follows: 1. INSTALLATION. The Company agrees to install in the utility trenches or other areas as required by system design, all facilities, excepting interior wiring, necessary to transmit television signals to and within all the dwelling units within the Development. The installation will include but not be limited to, cable and amplifiers, line splitting devices, conduit, amplifier housing and all facilities related thereto (the "Facilities "). Company agrees to install both 1" and 2" conduits as specified on design. As soon as possible, Owner shall provide to Company a legible set of plans for gas and electricity facilities at the Development. Owner agrees to provide all utility trenches and backfilling of said trenches at no cost to the Company. When Owner places utility trenches at street crossings prior to performing trenching on other portions of the Development, Company shall provide Owner with materials only and Owner shall places them at the street crossings. Owner shall provide to Company at least 2 business days notice of utility trench opening. In the event Owner requests that Company replace or relocate existing facilities at the Development, Owner shall reimburse Company for all costs for the replacement, undergrounding or relocation. 2. pREWIRING. When the dwelling units being constructed by the Owner reach the stage where electrical wiring is necessary, the Company agrees to furnish all necessary materials, specifications 1228 and design prints for the purpose of prewlring each dwelling unit with up to 2 outlets per unit. The Owner agrees to prewire each dwelling unit to all Company specifications including but not limited to, cable, wall plates and all prewire materials. Owner shall provide to company a list of dwelling unit addresses when it becomes available. 3. GRANT OF EASEMENT. By execution of the Agreement, Owner hereby grants to Company and its successors and assigns an easement and right -of -way over, across, along and under the Development for the purpose of installing, constructing, reconstructing, repairing, replacing, operating, maintaining or removing Facilities. Company shall have the further right to enter upon the adjacent lands of the Owner for access to the right -of -way and for all purposes in connection with providing cable television service to the Development. The Owner represents and warrants that it is the Owner of the Development and has the right to grant easement. This easement shall inure to the benefit of and be binding upon the respective heirs, personal representatives, successors and assigns of the parties hereto, and shall remain in full force and effect so long as the right -of -way shall be utilized for the purposes for which this easement is granted. d. OWNERSHIP OF THE FACILITIES. Title to all of the Facilities installed in the Development pursuant to this Agreement shall at all times be and remain vested in the Company. 5. SUPERVISION. Owner agrees to provide supervision over and coordination among the various contractors working in and about the Development in order to prevent damage to the Company's Facilities. Any expense to Company due to damage to Facilities caused by the Owner, its contractors, agents or subcontractors, will be billed to and promptly paid for by the Owner. 6. SERVICE. The Owner agrees that it has not and shall not grant, convey or otherwise transfer to any other entity any right to construct operate or maintain a cable television distribution system, satellite system, multipoint distribution system, multichannel multipoint distribution system, or other similar systems within the Development. 7. AUTHORITY OF OWNER. The Owner warrants and represents to the Company that it has full right, authority and power to grant to the Company the rights and privileges granted herein, and the Owner agrees to indemnify and hold the Company harmless from any claims, losses, costs or expenses incurred by the Company arising out of the breach by the Owner of the provisions of this Paragraph 7 or out of the failure of the Owner to effectively vest in the Company all rights, privileges, casements and rights -of -way described in Paragraphs 3 and 6. B. FUTURE DEVELOPMENT. Owner agrees to give the Company reasonable advance written notice of its intention to undertake any new development in the vicinity of the Development and grants to the Company the exclusive option to install its facilities as Bet forth in this Agreement by written notice to Owner. The Company agrees to notify the owner in writing within 60 days of receiving said notice from owner of the Company's election to install its cable television system in such new development. 9. TEEM The term of this Agreement shall commence on the date above and continue in effect consistent with the term of the franchise. 10. NOTICES AND PAYMENTS. Any notices or other communications provided for herein shall be delivered at the addresses set forth below or at any other address which may be specified in writing by the parties hereto. 1229 11. GOVERNING LAW. This Agreement shall be governed by the laws of the state of California as to interpretation, construction and performances. 12. F.NTIRF AGREEMENT. This Agreement constitutes the entire understanding between the parties and contains all the covenants made between the parties with respect to the subject matter hereof. This Agreement supersedes any and all other agreements by either party, either oral or in writing, with respect to the subject matter hereof. 13. AMENDMENTS. This Agreement may be amended, changed or modified only by written amendment executed by the parties hereto. 14. AsSIGNHENT. This Agreement. shall be binding upon and inure to the benefit of the successors, assigns and heirs of the parties hereto. IN WITNESS WHEREOF, the parties has executed thin Agreement as of the day and year first above written. ONNEA: Chris pher Lloyd By: By Title Address: C/O Conway s Associates 135 Liverpool NA Cardiff, CA 92007 Odum Address: 5720 E1 Camino Peal Carlsbad, CA 92008 state of ^ ra 1 county of 1230 ac 7 1443 before M. K---A 'c• -1 �OOOi M salvo ) — o. e..lw s z L1 r ' personally appeared rwwrad e ❑ personalty known to me - OR •Ri proh'ed to me on the ba_vle of sadsfactony wAdence Were appeared to be the person(s) whose name(s) `personally personally known to me - OR • ❑ proved subscribed to the wKNn huUument and as knowledged to me ttat helsheMey executed ' the same In his /her /their authorized orris capacily(les), and that by his/her /their ture(s) on the Instrument the penon(s), NANCY K ROsuu. UCK +o- M. U �a�j�o.pesA sl the entity upon behalf of which the a�lla�et less .orw..wc =•� '"10 "1O CO1Nn �w or non( e ) acted, executed the Instrument. pe VyfTNES§ my hand and "'sea c. gannearew WITNESS my hand and official "al. rwa a torwn "1411 Deni/f salvo ) — County of G Dcrs.eA s rr- / 3 Delora m., p DlutFaJAK �; e,a..rmsaarrcet tn. weave MTV 5On i appeared ewnavwars `personally personally known to me - OR • ❑ proved to me on the basis of satblaccary evidence whose namd(s►19are to be the personN subscribed to the within ynhu wnt and ac• ' knowledged to me that fa(alte71w executed the same In Melhedfh fc authorized capaclly(Teil and hat by hWhsr7their slgnnturet*)An the NsWnenl the persorh(s), U �a�j�o.pesA or the entity upon behalf of which the a�lla�et less parsontsjActed, executed the instrument �w VyfTNES§ my hand and "'sea c. gannearew 0 Mass REGARDING REOL jBY. COhWO ZT'.I LAND TNLE C04APANY DDC 4 1992 - 0175477 27 —MAR -1992 03:48 PM AND YXIND T CORDED i E q Nt Ills DELD AX i ¢62 OFFICIAL RECORDS SAN DIEGO COUNTY RECORDER'S OFFICE ANNETIE EVANS, COUNTY RECORDER Bruno Del Bianco and RFI 6.00 FEES: Beatrice Del Bianco AF: 7,00 DC L2568 Lone Jack Road Nf: 7.00 Encinitas, CA 92024 J 464- a X0 -1_3 TAX: 275.00 TIT" ORDER ae, 142269 te420e to SPICA ANONE THIS LINK Tot I¢OoRDn's 0- n I N D I V I D U A L G R A N T D E E D THE UNDERSIGNED GRANTOR(S) DECLARE(s) DOCUMENTARY TRANSFER TAX is $ 275.00 (XI computed on full value of property conveyed, or ( ) computed on full value less value of liens and encumbrances time of sale. ( J Unincorporated area [X[ City of Encinitas , AND 289.00 / USX tf��� FOR VALUABLE CONSIDERATION, receipt of which is hereby acknowledge CHRISTOPHER S. LLOYD, a Married Malt, as to a 9 /12th interest, GREGORY CLEARY L as to 2 /12th interest and CHRISTOPHER S. LLOYD, TRUSTEE OF THE GREGORY TRUST UNDER THE WILL OF MARGARITA Z. IJAYD nATED SEPTEMBER 11, 1980, as to 1 /12th E Interest hereby GRANT(E) to: BRUNO DEL BIANCO and BEATRICE DEL BIANCO. Husband and Wife as Joint Tenants the following described reel property in the county of San Diego, State of California: PARCEL A: 106 of CITY OF ENCINITAS TRACT 87041, in the City of Encinitas, County of San Diego, State of California, according to Nap thereof No. 12816, filed in the Office of the County Recorder of San Diego County May 21, 1991 as more fully described in Exhibit "A" attached hereto and made a part hereof. THIS DEED IS MADE AND ACCEPTED AND THIS PROPERTY IS HEREBY GRANTED SUBJECT TO THE DECLARATION OF RESTRICTIONS RECORDED concurrently herewith IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, CALIFORNIA. SAID DECLARATION OF RESTRICTIONS IS HEREBY INCORPORATED BY REFERENCE INTO THE BODY OF THIS INSTRUMENT, THE SAME AS THOUGH FULLY SET FORTH HEREIN, DATED February 27; 1992 STATE OF CALIFORNIA W ICIPL SE }L fJMP,ERLY RAY N NO,A. w01 -C NALIICRNY WALIZ.L COIN( Ix Sul LIZ Go COUNTY YY Gmm�wnf.o Lot 30 IY92 I a • ,a F ]?L Ilnomowy) FOR NOTARY SEAL OR STAMP STATE OF CALIFORNIA COUNTY OF So._ ti,eSu 83. On 03-06 -92 before ma. the under- alSnaO, • NoUry WtNle M erngp Ear aald County and SUW, per O * y appeared . personally known to m• (or proved to " on the beets Of aaba(aotory Ovloanu) to be the Pttaat wnOM name aYORnbed to the wltnin lrwrumenl and WknOwledped ttet he eaecut*o ma aarr. WRN y 1 nd and ^Of Ee,l� . 1 t,�, zuOf:6ra- 1A., pttv.4 I Ne vs (Typed or Rimed) 463 ` T rirt:: •. tCAL UEBCRIPTION 464 rjrcol t. Lot 6 of City of Encinitas Tract 87041, In the City of Encinitas, County of Ban Diego, State of California, according to Map thereof No. 12816, filed In the office of the County Recorder of Ban Diego County May 21, 1991. RBSBRVINO THEAIPROM, an *&moment and right of way for ingress, egress, road and utility purposes, over, under, along and across Lot 6 of said Map No. 12816, as shown and delineated as 'Proposed 32 foot Private Road Basement ". gold Basement is hereby declaesd to be appurtenant to all or any portion of said Map No. 12816 and all of that portion of Lot 1 In Section 8, Township 13 South, Range 3 Nest, San Bernardino Meridian, according to the Official Plat thereof, together with that portion of Lot 16 of the Subdivision of Rancho de I&* Encinitas, In the City of Encinitas, County of San Diego, State of California, according to map thereof No. 848, also known as Assessor Parcel No. 264- 240 -03, and for the us* and benefit of the present and future ownsta thereof. Parcel BI An easement and right of way for ingress, egress, road and utility purposes, over, under, along and across Lots 1, 3, 4, 5, 2 and 7 of City of Encinitas Tract 87041, in the City of Bnc Lnitae, County of eon Diego, State of California, according to rap thereof No. 12816, filed in the office of the County Recorder of San Diego County, May 21, 1991, as shown and delineated as "Proposed 32 foot Private Road Easement ". BXCEPTINO therefrom any portion lying within Parcel A. Said Resonant is hereby declared to be appurtenant to all or any portion of said Map No. 12816 and •L1 of that portion of Lot 1 in Section 6, Township 13 South, Range 3 Wait, Ban Bernardino Meridian, according to the Official Plat thoroof, together with that portion of Lot 16 of the Subdivision of Rancho do law Encinitas, in the City of Encinitas, County of San Diego, State of California, according to map thereof No. 848, also known as Aseeseor Parcel No. 264- 240 -03, and for the use and benefit of the present and future owners thereof. Parcel CI An easement and right of way for road and utility purposes, 32.00 feet In width over all of that portion of Lot 1 in Section 8, Township 13 South, Range 3 West, San Bernardino Meridian, according to the Official Plat thereof, together with that portion .6f Lot 16 of the subdiviaion of Rancho de las Encinitas, in the City of Bncinitap&_.�nty of San Diego, State of California, according to map thereof No. 84B, filed,in' the office of County Recorder of Ban Diego County, State of California, June 27, 1898„ described as followst Beginning at the Southwest Corner of said Lot 16, thence Easterly along the South line of said Lot 16, 696.78 feet( thence North 2 25' 09" Neat 475.03 feet, thence North 2 25-19- Nest to the South line of that 30.00 foot pipeline easement granted to Olivenhain Municipal Water District, recorded July 25, 1977 as File No. 77- 296591 of Official Records of said Ban Diego County, thence Easterly along the South ling of maid pipeline saeoment, to the centerlino of County Road Survey No. 554, (known an Lone Jack Road( as shown on Record of Survey No. 6085, filed In the office of maid County Recorder on August 14, 1962, being a point on the arc of a non - tangent 570.00 radium curve concave southwesterly, a radial line of which beers North 67 43'39' Seat, thence southerly along maid 570.00 foot radium curve through a central angle of 01 24' 26' a distance of 14.00 Net to a point on the centerline of said Road Survey 554, said Point being the true point of beginning( thence South 69 08 "08' West 665.33 feet to a point on the beginning of a tangent 984.00 foot radium curve, thence EXHIBIT "A" 111R 25 '92 17:32 '14 835 4201 PAGE .004 X5/92 17:50 2714 535 4201 COMMONWEALTH 0005 465 (Legal Description - Exhibit "A" - continued) Parcel C (continued), westerly along a tangent 984.00 foot radius curve concave northerly through a central angle of 22 07'07" a distance of 379.87 feet to a point on the northerly line of the property ae dancriWd in Exhibit At as recorded in Document 85- 119994, said point also being a point on the mouth lint of said 30.00 foot pipeline sammeent granted to Olivenhain Municipal Water District, a radial line of which bears North 01 15' 15" Want) thence westerly along the northerly line of the said property as described In said Sxhibit A, *aid line also Wing the South line of said 30.00 foot pipeline ea*emant granted to ollvenhain Municipal Water District, a distance of 73.19 flat to a point on the beginning of a non - tangent 1016.00 foot radius curve concave northerly, radial line of which Wars North 05 01' 36" Cast, thence masterly along said 1016.00 foot radius curve through a central angle of 25 53' 28" a distance of 459.16 festr thence tangent to maid curve North 69 D8' OS" Last, 665.43 feet to the center line of sold County Road Survey No. 554 (Lon* Jack Road) being a point on the arc of said non - tangent 570.00 foot radius curve concave southwesterly, a radial line of which bears North 72 21'11• Zest, thence northerly along said curve through a central angle of 03 13' 05" a distance of 32.01 flat to the true point of beginning. n u nocorded d DE�or — loot LOC 4: 1991- 0178724 C0641dONWE&TH LAND T)TLE INSURANCE a l Y —NYK— l YY l l.: r c S r M RECORDING REQUESTED BY[ C/0 :n• e.:u ... [.:LL;f : ;t•i CHRIS LLOYD 1 CONWAY L ASSOCIATES, INC. ) "'r"I[['ch +'. .IM•[K.uhrLa 135 A LIVERPOOL DRIVE ) tf r h vv ' 6L'i �[ • �e' CARDIFF, CA 92007 ) WHEN RECORDED, MAIL TO: ) CHRIS LLOYD C/O ) CONWAY i ASSOCIATES, INC. ) 135 A LIVERPOOL DRIVE ) CARDIFF, CA 92007 ) SPACE ABOVE FOR RECORDER'S USE ASSESSOR'S PARCEL NO: 264-240 -02,03 GRANT OF PRIVATE ROAD EASEMENT CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA E. LLOYD, DECEASED, PROBATE NO. 15976, (GRANTOR) FOR VALUABLE CONSIDERATION, GRANTS TO CHRISTOPHER S. LLOYD , A MARRIED MAN AND CHRISTOPHER S. LLOYD AS EXECUTOR OF THE ESTATE OF MARGARITA Z. LLOYD, DECEASED, PROBATE NO. 15976, (GRANTEE) , AN EASEMENT AND RIGHT OF WAY FOR ROAD AND UTILITY PURPOSES, 32.00 FEET IN WIDTH, TOGETHER WITH THE RIGHT TO INSTALL AND MAINTAIN UTILITIES AND TO INSTALL AND MAINTAIN SLOPES AND DRAINAGE FOR THE BENEFIT OF SAID 32.00 FOOT EASEMENT, OVER A PORTION OF REAL PROPERTY, THE LEGAL DESCRIPTION OF WHICH IS AS FOLLOWSf SEE EXHIBIT A THE DESCRIPTION OF SAID 32.00 FOOT ROAD AND UTILITY EASEMENT IS MORE PARTICULARLY DESCRIBED AS FOLLOWS1 SEE EXHIBIT B GRANTOR SHALL NOT ERECT, PLACE OR CONSTRUCT, NOR PERMIT TO BE ERECTED, PLACED OR CONSTRUCTED, ANY BUILDING OR OTHER STRUCTURE, PLANT ANY TREE OR DIG ANY WELL WITHIN THIS EASEMENT. GRANTOR AND GRANTEE HAVE THE RIGHT TO GRANT UTILITY OR PUBLIC SERVICE EASEMENTS TO OTHERS ON, OVER OR UNDER TBE LAND COVERED BY THIS EASEMENT. IT SHALL BE THE RESPONSIBILITY OF GRANTEE TO MAINTAIN AND LANDSCAPE THIS EASEMENT. THIS EASEMENT SHALL BE BINDING UPON AND INURE TO THE BENEFIT OF SUCCESSORS, HEIRS, EXECUTORS, ADMINISTRATORS, PERMITTEES, LICENSEES, AGENTS OR ASSIGNS OF GRANTOR AND GRANTEE. IN WITNESS WHEREOF, GRANTOR EXECUTED THIS INSTRUMENT THIS 1 RY6 ❑AV OP APATT. 1991. D � I 1662 STATE OF CALIFORNIA ) ) SS COUNTY OF SAN DTEGO ) On April 18, 1991, before ms, the undersigned, a Notary Public in and for said State, personally appeared Christopher S. Lloyd, proved to me on the basis of satisfactory evidence to be the person whose name is subscribed to the within instrument and acknowledged that he executed the same in his capacities, and that by his signature on the instrument the person, or the entity upon behalf of which the parson acted, executed the instrument. WITNESS my hand and official seal. .� - Pu✓ n a in �J Diary bl c n e for ,2 said County and State PL /ACK -LL02 a nCU Mn LEONA V. KAUFLIN EOOCTOBER pBTIJ1 dEadCW�W" M, Gu,mirlon E�dM 8, 199 1863 EXHIBIT A ALL OF THAT PORTION OF LOT 1 IN SECTION B, TOWNSHIP 13 SOUTH, RANGE 3 WEST, SAN BERNIIRDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF BAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO NAP TREREOF NO. 848, FILED IN THE OFFICE OF COUNTY RECORDER OF SAN DIEGO COUNTY, STATE OF CALIFORNIA, JUNE 27, 1898, DESCRIBED AS FOLLOMSt DBGINNING AT TBB SOUTHWEST CORNER OF SAID LOT 161 THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEETI THENCE NORTH 2 25' 09" WEST 475.03 TEST I THENCE NORTH 87 34' 51" EAST 669.02 FEET TO THE TRUE POINT OF BEGINNING 1 THENCE SOUTH 87 34' 51" WEST 669.02 FEET F TNBNCS NORT9 2- S l WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPBLINE BASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 296591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTYI THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPBLINE BASEMENT, TO THE CENTERLINE OF COUNTY ROAD SURVEY NO. 554, (KNOW AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF SAID COUNTY RECORDER ON AUGUST 14, 1962; THENCE SOUTHERLY ALONG SAID CENTERLINE, TO IT'S INTERSECTION WITH A LINE THAT BEARS NORTH 71 12' 24 " EAST FROM THE TRUE POINT OF BEGINNING) THENCE SOUTH 71 12' 24" WEST TO THE TRUE POINT OF BEGINNING. END EXHIBIT A - PAGE 1 OF 1 1664 EXHIBIT B ALL OF THAT PORTION OF LOT 1 IN SECTION 8, TOWNSHIP 13 BOUTS, RANGE 3 WEST, SAN BERNARDINO MERIDIAN, ACCORDING TO THE OFFICIAL PLAT THEREOF, TOGETHER WITH THAT PORTION OF LOT 16 OF THE SUBDIVISION OF RANCHO DE LAS ENCINITAS, IN THE CITY OF ENCINITAS, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 848, FILED IN THE OFFICE OF COUNTY RECORDER OF SAN DIEGO COUNTY, STATE OF CALIFORNIA, JUNE 27, 1898, DESCRIBED AS FOLLOWER BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 16; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID LOT 16, 696.78 FEET( THENCE NORTH 2 25' 09" WEST 475.03 FEET ; THENCE NORTH 2 25' 19" WEST TO THE SOUTH LINE OF THAT 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENRAIN MUNICIPAL WATER DISTRICT, RECORDED JULY 25, 1977 AS FILE NO. 77- 296591 OF OFFICIAL RECORDS OF SAID SAN DIEGO COUNTY; THENCE EASTERLY ALONG THE SOUTH LINE OF SAID PIPELINE EASEMENT, TO THE CENTERLINE OF COUNTY ROAD SURVEY NO. 554, (KNOW AS LONE JACK ROAD) AS SHOWN ON RECORD OF SURVEY NO. 6085, FILED IN THE OFFICE OF SAID COUNTY RECORDER ON AUGUST 14, 1962, BEING A POINT ON THE ARC OF A NON- TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTH 67 43' 39" EAST; THENCE SOUTHERLY ALONG SAID 570.00 FOOT RADIUS CURVE THRU A CENTRAL ANGLE OF 01 24' 26" A DISTANCE OF 14.00 FEET TO A POINT ON THE CENTERLINE OF SAID ROAD SURVEY 554 ; SAID POINT BEING TEE TRUE POINT OF BEGINNING ; THENCE SOUTH 69 08. 08" WEST 666.33 FEET TO A POINT ON THE BEGINNING OF A TANGENT 984.00 FOOT RADIUS CURVE ; THENCE WESTERLY ALONG A TANGENT 984.00 FOOT RADIUS CURVE CONCAVE NORTHERLY THROUGH A CENTRAL ANGLE OF 22 07' 07" A DISTANCE OF 379.87 FEET TO A POINT ON THE NORTHERLY LINE OF THE PROPERTY AS DESCRIBED IN EXHIBIT A SAID POINT ALSO BEING A POINT ON THE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENRAIN MUNICIPAL WATER DISTRICT , A RADIAL LINE OF WHICH BEARS NORTE 01 15' 15" WEST 7 THENCE WESTERLY ALONG THE NORTHERLY LINE OF THE SAID PROPERTY AS DESCRIBED IN EXHIBIT A, SAID LINE ALSO BEING TEE SOUTH LINE OF SAID 30.00 FOOT PIPELINE EASEMENT GRANTED TO OLIVENHAIN MUNICIPAL WATER DISTRICT, A DISTANCE OF 73.19 FEET TO A POINT ON THE BEGINNING OF A NON - TANGENT 1016.00 FOOT RADIUS CURVE CONCAVE NORTHERLY, RADIAL LINE OP WHICH BEARS NORTH 05 01' 36• EAST; THENCE EASTERLY ALONG ALONG SAID 1016.00 POOP RADIUS CURVE THRU A CENTRAL ANGLE OF 25 53' 28" A DISTANCE OF 459.16 FEET ; THENCE TANGENT TO SAID CURVE NORTH 69 08' 08" EAST, 665.43 FEET TO THE CENTER LINE OF SAID COUNTY ROAD SURVEY NO. 554 (LONF JACK ROAD) BEING A POINT ON THE ARC OF SAID NON- TANGENT 570.00 FOOT RADIUS CURVE CONCAVE SOUTHWESTERLY, A RADIAL LINE OF WHICH BEARS NORTE 72 21' 11" EAST; THENCE NORTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 03 13' 05" A DISTANCE OF 32.01 FEET TO THE TRUE POINT OF BEGINNING. END EXHIBIT B - PAGE I OF 1 DA3 '96 10:07 ID:LANIERFAX3800 ' MAIL 1861 rmFIlMIayM1Nr I0. tlwk, EO„d 01 Ea0eMi1ela Ern tEFoci Op I Covnty AomInIONdOnCmbr s11�YgN(//�tnry DW Of"M SEWICE7 N01AAMpERTAXO4F Aawwry hnml Ne. (H- 010-10 :� lro=ai FAX: 855-- 033995 Ns LII I M 1. 56 KPI I. caMfrrl +,30rfN 1pFF.E SPACE A oR REC0010111 LIN ONLY .� ORANT Of OpEM vACE pY(MLINT rrawct TMIIWI wo No, FONOI NO.. N- l4 Nn. - _ 9564- W IR(YR(ITA I. 1.100, . widow AMU CMRIS(OPNER on ailaiOrrt(d on rrrram InaJtl(Y �n Im Ow.r.a of dlr fEi EIAp'L( EETATF h rod 4 Na Iwp M 1M Crernty .1 Ern Dap, E�talt .1 Camcorhi. aawrAOd In Exhibit -W rnilwd hurt. ("rho BOOM land'): whm a.b 1. a. rn.r b• .A)aat to pal Moto 4ne4. m .W.. 90n41tlmk multdaw OM w m 01 v the Mm0 eery b 01 record, and !. II l tM Nlm al tM Or1mw the G„my N Nn Dap, 1 p ACE mbdel,b• nl Na ibp 0I Gbrwrda Inwwe afbr MfMfad m tl "C011Niy'1. Ntt tM iubMn LaM nmUn OO(N SPACE MOW T4EN1R001, I. TM GRANTOR prmY 4 wlr c.wnty, W A arr..MN rawwwn< Iw OO1N MACE ►w,pOOrO wv, uam, arlaw W anon NO E,Ib1Kt UrW. Grp n0 bull/ k't Me,,c" 0, other Ihlry wMlaOwrr anon M Can4.IwMd. wwt.d, Mara w InonwMa an th. Eukllwt Lan" Oavpt r O.MF AI The pa,p.hwt ridrk W, nor tM owipdwl td rM.r rp.n ho Plbltwt l..d end nmvn M b.11dlnp, on101ww W Odw O,hy uOsbawvl, oOnM„4trd. OWNCI. pbvd w M16tinrd W N. EublKt lop uonpry to I" totem fo.Mnnd H OwpiYen of LAW atlmN.i rN to dot army wwk Mratlry waMwnNa 94 •oU.��ts at May A, ,. Or a101 l 91 MV, Wl Wk K I FIr11 K Any other rMNrld danO w %x40 On 1hr SeMFI Land Contrary an any IsI eormam or Omdtlonr of iNl aawnwnt, !. OIVINTOR wrwwMa Ord oprr M OkrrMll arW by awwawwa orAOFpnw ■ kablrr W Thai M "I "I Mom tarwtNt% pldrd Or ",MI., or pnaa"o,KaOA tM I,,...pn plaRmpnl of r"Ina, n W OR bitllnp M airvopna Or DOW lNry.,Na4 o pn OW Walt" Land Othw then kWh buNOtrgt mclam &V aNw thing, x,nor be pwminad puryMn to IM OOnlnp ardlnwe N III@ Camty t4 San D4p. IN TkM M WN not w the "Mmi Land for my pwrpata View 0 Or1N A•ACE W Tarry IC) ThtlMMN rotwvwW wwOMwgrrit ary ww.rwngvpraMlp nMtMlla. wp4wwilento MalwK my taro, LNl Wk. prMd w oO w w44rlw WMatwww m pit AMoai Lord wdNOUt W wrlttan NlwNabn i tM Caamy w In wacrwn w WI provided, howm , wet Granter "ww m% FM Of prop ta.d, NO, IKk E,wal w ON.r mabrlai M pw kMK. Lknd M mat b. pranittad W*Klal Ytw pmnit Arad pw44M 4 w. eon" w W ran at the Cowrty 01(m DMI - lDl TiNi dV Wirrw fAMr11Y rM rall�tkwra rM LwtY nM.ln I1rt' r pawl$ 11 "k, w' L' ' — by pMHad Iti, Jr, lw (woo, IV CaINt OI NO Swot N CWwlll, TM pNM N NIL tl of and In" thileof m rot or wfrr ey,on a( warp Y ta4M W mWki ft Mat W whk% ft Thil OrIOn,.I, W II Mod t1w Oranwr W Np ttNwwM11/ wl TOP FZ SD 1985 -33895 Page: 1 of 4 V a l., 04/03 '96 10:08 iD:LANIERFAX3800 1867 E111115IT "N" rarfol M. 44. 0123 -d (10- 31 -61) (M: Oft at) FAX: That portion of lots 1 and 2 In Section 6. Township 17 South, Ranee 3 Merl, San Beraardlne ease ens herN /an, accwdiag to official plat thereof. TOGETHER with Lot It of the subdivision of Raache Las E,cloltas, otcordiq to leap thereof MI. 146, filed is the Office of County Recorder of Sao Diego Canty, JOee 27, 1690, all being In the Canty Of San Dlsoe, Sete of California, described In dead to No rite Z. Lloyd, at el, retar'd's Hey 12, 1911 K File7hya PA. IPD349 In he Office of the County Recorder e/ told Nn Diego County lyteg Westerly of sir Westerly Riot of pay Ito of Loo Jack Road. Reed Survey ft. 564, aaordl to Rotors of Surrey Re. 6M filed In the Office of said County Recorder. AND tying Easterly of the following delorlbed line: Coinenciag at the herthent corner of laid lot 16; thence EastNl) along the North 11" of aid Lot 16 1 distance of $50.00 feet to the TRUE POINT OF BEGINNING; thence South 03.15'0' Cott 710.00 feeti than" Sat 63.15'17• Cast,63D,00 feett thence Sntb 61'15'47" Nett 490.00 feed theme Seulh 07'1647' Ent 760.00 fort{{ thence Seth 66.30'00' Fast 800.00 (set:; thence South 1030'00' East to a point in the South It" of sold lot 16, which lin 1440 fast Easterly, along the South line of said lot 16 Iron the Southwest corner thereof, sold point beiq a POINT Of TIRNIHITS. No parelt of any type 51,911 be Issued far any drv,10sment witMla this "SaMM t watil a GOtecMtal Report has been wboitted and approved by the Director of PIsmi np and Land Use. Dne1a t will be allwW by site plan inter 9PprOval of the CaateeMltel Msort- T 15 tits plan review Would be for W site puryow of assuring Chet fulare building 111111 ere free free laedalldes, expensive yell, or flooding problws; and that +deyuatc ecesures rove bnn teen to ache altss Safe. Review of each ►wilding site an be don eaperetely. TOF: FZ SD 1985 -33895 Page: 2 of 4 r PAGE 04%03 '96 10:08 ID:LANIERFAX3800 FAX: lass This Optn 3p1ee [wemenl Jell pndude repul.. remove) a Mdltb.r Wrh tha exception that kWh C"Iftlnp for Ibs praetllon PWOp s shall be petmines upon rsitton ofoat by hit ageoprlate fin Iljh" a the protection ty""kao, The •loreelowi6d "e,Mm, Me wnditlons shall Ilol preetttr the Iw e[ the r) had V aaU a lots, twwluiM l wluiM ofl aie lcflyeand cern� nle�ilkrq Ayee�l J bwa floe plbllc eUllty cdmpny, ihab repnunlativ<, etrcnws a ostipr, Any %W paWlc etlllty I:Ompany. In repntenfative, lIK"Ilvt or assigns shall ttrmit feat t(al)k oay *X, sots wemenl for the pupae of installing Wd rhea and cables. Any said alk blilty, eanpeny, Its mwetenlattw, toccesta x aalane, shell rot plaeo or In +I W any py� I" re, p ss a any Do. .Pwwn mI o, to rid "ages and "Inn Upon OF vMrf tr,e pound Ixrlace of MW wemw.t, and shot[ not ttaro or snckplle anythlq r;tkM ft bovndnl" of told ea,ement althaul pia mitten approval d the Director of the C.ov •y of San Diego fneper"Ormt at plannftyf and Land lru. Any ulo puaglc umlty Ceapeny. III reprOantatlw, sKMa> r assign, shall •grda. dus sac atdio bei rlihin no bandary N mid eentnent 10 paterw she Intent of creatiry Ihy Open Spce Qwment, TOP FZ SD 1985 -33 L to r r ,ee 04/03 '96 10:07 1D:LANIERFAX3800 r.,... n atCOADID, A FYI M.II IS NK1nVMENT 10, Y, sad of tupexlean DIOW CNAmly Ad. Inl,tnllon Caner Fm1tA MaJa 101 GENERAL SERY03 TRANSFER Ti AX OUF FAX: 65'�OJ3B 195 Y C[N 1rya`a -1 f .j IJ P d! 0 49 C`ini 16a 7 M M 31 IM 1154 1 CW1yrJ:lkMR IIOFF.E PACE A OR RECOR a USE ORLY_ ,_ GRANT OF OPEN VACS BASEMENT Av.."1 Aral groom TN11011 � Iu- oPO•tD w.G.Na tE ETi — ISF7E531 Panel R Lm a . ._ _ ._ 9N 5 64 [— i yRATA I. LLOYD, a M1dor AMU VRISFOPHER 1. 1 _L,LQTO. an aeeaarrL* edn wwTant tlul tMr arf the owrw,e of The FEE 8114M ESTATE In and it the taMI In the County of 4n ON1p, flute M COMornla, dMOW In Exhibit "A' a„eahed hereto ("The lobiet, Lard-l' nhfdl "late Is or may W WA)a to fall Mad pan, "namwnM. aondti" ,aulltom and monam dl w tN Memo may be of reword, and E. It IS tM dealt, of the Granter and the CoamY al Ean Olden, s politl.al wtddlb, no that 1bn of California Ihxd. ahea IFlmd t0 a'COuflTY'9. Nat IM Seoul Lend r,maln OPEN PACE. NOW THEREFORE, 1. TM GRANTOR ErMYto lM Cwnty, W in prw ltA eMto n of whet b thin, lnD, PwEMN VeoAeCer S bell enr, eapn, wrw .ed ender No S,.bleM Lerd..M eta WIN M CMH.acwd. •rated, pWe a m,invuW on tM subiwl lei $Rapt a "'AN. III) TM perpeta, rat, but not the obItpolon W emx won WO Wbjm Lrd end lama/o any Wilding,.IrwNe" v ather "p". If aonw,w of, fret" PW d a meMJnad on Ma Srblw, Lord mnaary to any Mm cOanent an condition of Nil nMfeaal and to do any work necase" N FRnlhaa the aMcb of my sate a4M Or pnaMnl al aon f, DIL roan d as.et or any .her mWWI done or RNad an the Seblacl Land contrary W My term Co.anam or, /ordldona of INS taaement. i OMNTOR ewerra,l"arod •Pew br atrr,wlland Ab atwaaeawe andaeaiara ea,aWMa: ['j W That M dill not reM o atrucL plate or mlinMin, or pernR Uta eMOeM1 eanMWellore pMCemRN 0, mints aro at arty W11" M S1ra0Mro or OIM thlr,p whalsower On lint ll bmw Lad other IherM With boRdtnpl aeattora Md what TWO, IN may be WmttW Wae1Ml Is IN aonlnE Ndlaanm Of d,a County Of Ean DNp. UI That M WAN net w tow 8"Mol Lard for any Mupw, twtW a OPEN PACE "upow, ICI Thal M•e %tree WMM,Vbradsa permot, any Natant" ayadnl IN be don, or plead wsiL eto tN prom my sand, aell, rook pant or Other m a rlr waateae.sr M Olt 1101e[i lend Mthwil W RrlMan "Mini" el the County w In raarwt at a"IErtw p,,Add, M.M,, vMt Urania, troy a. Ik Enm or place toad, MR, tack /IMI a tow, mamlal On tIN Subject Land a me, be Permitted WWaClbi ow pamll Iwd SAWWA l u oR tonne ordm"a, oI pet County of Son Diego. 1D1 Thn dr MrmA m.enanM and wn0lNana .a forth hxd..w/ W apawlddly x,lwwd er yfelrled by ytKrwd ltua M IM irperly Caen et No Stag. d WNa,Na The nm W Dill usamenl and to euaplRKo by Goa Cow tMnof an tM w "tar Neon all a am ptMion of let, p,b Y At" b Mnkl N dml a whkh tM Eubloct Lams OW This alontalel aheN bind W Olanw Me hs "I oat sued artre trio Public ON any mmtbon iW.Lvomd owuhs4rinis el 101E em t Order: TOE' FZ SD 1985 -33895 Page.' 1 PAGE ire -7 /S W1 04/03 '96 10:08 ID:LANIERFAX3800 FAX: PAGE �rsc 1867 LANWI1 'A" Parcel (10-31 -64) (EK: OW: at) That portion of Lots I And 2 In Section 6. Townlhl9 13 South, Ran9t J West, San 1armlrdlno auto and Meridian, according to Official plat thereof. 7091TNFR with Lot 16 of the sub4lr /a4n of Rancho LOS taclnitn. according to lisp thanof No. 616, filed In the office of County Re00rder Of $ae clogs Canty, dugs 27. 16". all being In the Co6e ta ty of San Dig", Ste of IAllfimmie. described In dead to Mrgarite I. Lloyd, at 61, racerded MF IZ, loll at Fllar ► ayye No. 120349 In the offltt of the County Recorder el sold Nn 01090 County lying Westerly of lM Westerly Right of Way Itaa of Loea Jack Road, Read Swrq he. $64, accordlmY to Ma"rd of Surry Ma. 6615 Mail in the Office Of Said Canty Mcord f. AIO lying latterly Of the F911"lmg 4&$Cdbed Ilse: CoeAeneip at the Northwest corner of sold Lot 161 thence Easterly along this North lane of said Lot 16 a distance of 950.00 bat to the TRUE POINT Of IMMINRIeO. thence bath 03015'47' Cast 710.00 tests then" South 63015141• tast130,00 feed thq South 41'15'41" Most 490.00 feots theoca Seta 03'16'47 East 160.60 feat{{ thence South 66'30'00" fast ROOM fast. thaacs South 12430'00' East to s point In the South line of said Lot 14, which Ilas 1440 feet Easterly, along "a South line of said lot 16 from the Soutlwsl corset thereof, Said Point being A POINT Of TIRNIRUS. No paralt of any type shah be Issued for any RralOPmemt within this 94'm t until a Ssotechnlcal Report he buan submitted and approved b tht 01"ctor of Planning and Land Use. Danlopnmt will be allowed by site vlsn after approval or ton Aectechnteal gpprt. Tb1s Fite Plan "vide mould be Tof W tole pur9ou of &{wring that future building sites, are free from landslides, expensive sell, or flooding problems: and that adequate mcaw"t hove bean taken to Pee dtas Safe. Revleu of each ►ulldimg site con be dent separately. Order. TOP FZ SD 1985 -33895 Page. 2 of 4 Z 0443 '96 10:08 ID:LANIERFAX3800 Iasi FAX: This 0 -1 Jell procurer ew trn,,al a eed(tloa M,h dv ptbn . m cece IMt kWh Uteflnt fer eht prelectlen low", well be perTllwe 4pan wilt»n order ►y we appropriate Jim lighting a fire prolectiw..Aanelea, The aloredescribW Vrewis err, rondlnon well nol pnnnt the toe of tree aklpeca •bore "M srwrwet tar nt ItuiWatIon of electric VW lelefe.Ma paver codes and whew r« the ur lulen of awctrlcily and eemmwlcatlarr by any gang fide public etlllty rae isny, )hair reMemntaslvel aslaceasars w assipls. Any mid public went, campp++nyt In representative, Iwanlur or uti{tgm wall Permit fool tmilk Daly whin mN outnIt.l for the pwpo.. of irotsJling said vlrts and cedes. Any raid p►uuallc Willey umpeny, Its npfelenlall ee, aurnswr a wipes, shall rot pu or loath"polnf raven, "do a anti ether apgwwtiv.ees to mid cables arst wires upon w r.der tM pound srfact ai veil tuemmt, and .A.n .os star. er sloctplle anythinq eiWn IM lolmdrles W sold •a.w,nenl wirhIm pr{or wrllten approtbl W the Dkectx of tree r:ay.'r of saes Dl-g. Mtpo,ment of Fla" and Lane .e. Anf mid public vtitily company, III rep,esentatlw, &Deism r aas{a,w, Well exercise Cos cam while halo with).,. bowdary of mid waeament Ia presern the Invent of creallry Iva(Ipee Spac1 laument. TOP FZ SD 1985 - 330;;:. r r PPGE 3 r RECOI14 REQUESTED BY. OLNENRAII4 LfUNICIPAL IYATER DISTRICT. AFTER RECORDING RETURN TO: OLI'!CN:1- 79 VIINICIPAL Y41TZR DISTRICT. 1905 GLIYEIIHAIN RD. ENCINITAS, CA 92024 GRANT OP RIGIITOFWAS' r Ru.77 _ 1 2965:) OOA 1977 n._..DID REOIIEST Of LARD TNLE INSURANCE CO. A 25 8:07 AM77 SA14 DIEGO OFFICIAL COuAny. DCALIF. BARLEY F. RL09M RECORDER 304574 -1 MARGARITA Z. LLOYD. a widow, and CHRISTOPHER S. LLOYD. an unmarried man . . Ia Lw ...... I.., ..rid u. ,nn...lerannn 4 dw loan ..1 0.- I14.I6r And . aha ,.al.ulaa...n.Id.r.I....r1 +mlha OLIVENHAIN MUNICIPAL WATER DISTRICT, a public corporation._ ,.Lunn r..•; w1. 1• +'1 ^I ^'NLI�:.riNh'1.. •.h.IM!•I1a'!I:dlule�l OLiYEUHAIN MUNICIPAL 4.aTEP DISTRICT m awu +wn. an.l aaag•.a. An e...e,ueru ..1 nghl ul +.rr... .:;0. DD .... .... Ier1 m wuhh n.. uryn.. oaeq under. An.l r Ana the lan.ls h. •clnahrr -!.w nlw'.1, n• un L ...normal, ns.mwru. 1. r.plA, e. rd•A.r, nuuu mn in,l low A I••pehne or p,pad•nra lur am and Al puq•. oas, t. q:rdu'. auh Ih. r, M. r..Ar, a.mrta. aril Arpurrenuw ea ., too, long M.1 n..r horned n.Im dn,w far r..wl,r mmnuwnn Aal u.mmm�w..n.m rnq•.w.,p enl . h•.An..no and a la I ......... to al..a[.•il, r.uwl nn.la r dg beta u-.dM, dew rdeil right ul w a, A.1rumsa m.n .n,w 1., Iw r, 'le. r.lu no. n,ern..•r A.nl u- a -..., Ir. m--.:n. n. 1.1111. 1..11 th. r w lob 1 ha rmin•d Agra., -hue... An.l or n., o..-,•! A... a .,..I •q•h:..1 •. A•. L'... I r e •.. d I..wm . or r. +:w•. .... ..I..... ... a r m•' . n.oa. the la r..,,im r .1, 1, rha'.I I.I.Km4l.Iharanhdxuehr1..ua•u.1 nelrutw,., h.:..,. t,, m<,unrva.nghr...( w %lomand r, a•lu.am bit llm lam 1.11. alouh.aril r...unom ul r.g ht.,t wn I, I."Iw Pr.nleJ Aw ..... Al.lm I., I..unq n•..... San Diego .. i we nlI lot n....A.."O Are rarlu ulla \.Ifwrkavi Lot 16 of the Subdivision of Rancho Las Encinitas, in the County of Sail Diego, State of California according to the Map thereof 11o. 848, filed in the Office of the County Recorder of said San Diego County June 28. 1898. EXCEPTI14G THEREFROM, that portion lying Easterly of the center line of County Road Survey No. 554 (known as Lode Jack Road), as shown on Record of Survey Map No. 6085, filed in the Office of the County Recorder of said San Diego County August 14. 1962. Prepared hy: nnyle Fnryiaecrinq Corporation L.n.n. L• P. /W 0 '04!; 4 )R ?K. Date: FE.". //.I ^77 9 1 r M { r' I I 1 �I Prepared hy: nnyle Fnryiaecrinq Corporation L.n.n. L• P. /W 0 '04!; 4 )R ?K. Date: FE.". //.I ^77 9 1 r M { r' I I 1 .r 1 "I I ' :xl'�Y,l l.` -MS ^•Ire mni•i :pi...n u,r. u•Lr J.�., ..•i.11r � •p.�r. u�rL , .,.r.. .•l..lL .u. ,ill that portion of the above rli�scribrd property inr.luled within a strip of land 30.00 feet of even width, the center line of said 30.00 foot wide strip of land being described as fr,llows: Beginning at the Northwest corner of the Southerly 15.00 feet of Lot 15 of said Nap No. 846; thence along the Northerly line of said Southerly 15.00 feet, North 87 "34'47" East 851.36 feet; thence North 74007'02" East 76.93 feet; thence North 50 "11'46" East 54.65 feet; thence North 32010113" East 73.24 feet; thence North 13025'52'• East 344,42 feet; thence North 26033'54" East 87.21 feet; thence North 38'18'32•' East i27.44 feet; thence ':orth 54'[12'22•' East 63.01 feet; thence North 66'5?'a7" rest 06.77 fnpt; tYPnrp.. North 72149'nr" Gact 07,03 font; thpnC< North / 83'02'49" East 144,96 feet; thence North 72'40'40" Lest 1054.43 feet: thence North 65'33'21•' East 610.19 feet; thence South 88 "17'14" East 418.19 feet; thence North 67 "45'13'• East 932.40 feet; thence South 84'23'08" East 178.86 feet; thence North 69'39'39" East to the Westerly right of way line of said County Road Survey No. 554. TOGETHER Willi an easement for temporary working strips of land, situated within the lands first above described, said easerent shall include, but not be limited to, the right and privil +ge of s:orkren, contractors, and any and all agents employed by the Grantee herein, to u >e and occupy said temporary working strips for the purpose of constructing the herein;)efol•e mentioned pipeline or pipelines, and any and all appurtenances incidental thereto, and said easement shall include the right and privilege to place and operate any and all machinery on said strips which the Grantee herein, or any agent or contractor employed by said Grantee, deems necessary for the construction of said pipeline or pipelines. Said temporary working strips hereinabcve referred to being more particularly described as follows: A strip of land 20.00 feet of efen width, said 20.00 foot wide strip of land lying Northerly of, and immediately adjoining the Northerly line of the above described 30.00 foot wide strip of land TOGETHER. WITH a strip of land 20.00 feet of even width, said 20.00 foot wide strip of land lying Southerly of, and immediately adjoining the Southerly line of the above described 30.00 foot wide strip of land. It is hereby understood and agreed upon by the Grantor and Grantee herein, that the right and p<ivilege set forth for the use of the above described temporary working strips shall be in full force and effect from the date of execution of this instrurent, and shall continue in full during the construction of said pipeline, and that upon completion, final ilispection, and acceptance of the pipeline by said Grantee herein, the easement for the temporary working strips hereby granted and described above, shall cease and terminate, and become of no farther fnrre or effect. It is also understood and agreed upon by the Grantor and Grantee herein, that the grant and termination of the easement for the temporary working strips hereinabove described shall in no way affect or frustrate the continued enjoyment and use of the 30.00 foot wide ease^*nt first above described. ..,«...,.,.,., 1 <,,,rr, ..,,, ...,,.•................. •....- ..........._.... _._.- ....... ....• _ - . - ___.....__......... - _I.........,, rh. Jr., omen, r, ev, urea, • 11. m, rM• ph•rruus u nor , umKn1 of 1; iv Gumre In IllimegM ltlhrte t. IM t:unpr5 . have __ r.eru,vlrh,w•;rc.rms rhr s .....' ....L,ef- �4U- 'C,........ 1.1......!:. P',rne„ U nor„ - --rc\ "hue„ %o 264- 240 -01 R \c w,. 304574-8 ORA % \'N;1}' _ ..��r. I I II'.t IaD 115' .. \IC r NO C -001- 194 -03 [)All February 11, 1971 /je111 . F 1.11 .•'• Imm lr l'I 'ke.vised April 2'1. 1977 /jeh Prepared by: • Boyle Enginecr;ng Corporation eJ o ..... \01ARILS -1 "O PROPS ACE. to r.a ?04574 • R 04F Date: FC- -. V, in 77 t. 1 ii y t� I � vaI✓ o� Ur 10 ti l•ru nn and the r . wur ++•n, m c %,are •hall most, serer or a••mtrw t.+er permoc n. h tem;I",, connruaeJ, ant budding ,or ..hery comrr,plan,NnIce or trata•nr drill am well ,ar wells. ser,hin t he b mead tied right n( way Guns, +hall Woo the fight u, errar, reamtnn a,•1 I. cares in all fenny whuh no.w nn+,.. r hall hereafter tin„ and ,.mrr or ,.ware,, .m.l n, vin, anal ant and rkar away am tray, and brush whrorser in its tutlitnevni the umt shall how neca•,sary fnr the ann. ,,norm a,ul tit,. rxrn cc off flit r,ghn hrreb) grante.l, the right to tran+ter and naegn,hnr_ •merit,n whole nr in par, being here be cranial,., la hunter Or me... ..get" that roe wher tast,naro, ,,r seem, ,.,, ,hat! he gritted nn. under of mer said vnp of land by Grannie. wethout ,be pre, a au, w floor' .,risen, of (oumee their I n i ,,, an•ler,r,.. i an.! agree,) hs the ; tierce her +n that ''s Gunner and rim crews,% or nnsny,,hall rim muene 1 ... .......... r primr r., ht immrnaa.l of dr. rravJ. the exrvrng grnnn•r rlruuun, nl ,hr almost Jtwnhed right of w•ry'.a•umrg as the rime his J.., .,no,,, s a rn weJ. w rtlma: rhr prrr.nw ex rnten tonwm r.f ehs Gun,ee All Illllnen tuhrrn+l. he Granwr5..have ... ... ruauuJ arau• prrumn thn dada. /.......der of. - .442LS:....... 11) ..:...1.. luurad m fnr l'erun L _! L q'nnea R vl No. _ 30,11574—Roe. At (.1 NO C-001- 194 -03. IM-11 inliruary.11, 1977 /jeh• N NS. • -. too.... glut -ti aRevi Sed April 27, 1977 /Jell 1 Prepared by: Boyle Engineering Corporation L` NO1 ARIES —USE PROPER FORM ON BACK. C.A.U. C-00 1•/.^6.02 R/W F °04574•R ilE Date: ZxCe. N./. °77 MM i a. N -N- 1!1l1J ... INOIOArE5 PlArER UI J7 L /NE EASEANf'!.'T � to � n / •- 400 r Tax Par. A 204.140 -0/ Project: VN /T nKnR1W _ Base Map 9 3 FLAT a, REVISED 4127/71 cf o q•rnr,ts required ty the Oliver.hain Municipal uate- District C.A.U. C•00/•/94.0? Prepared by: P./k' C 3OA57c•R Doyle Cnginecrinq Corporation 4: Date: FE. °. /I.I ^77 i -41 �1 {1 •I 1�i 11 J RECORDING REQUESTED BY: ) DISTRICT ENGINEER WHEN RECORDED MAIL TO: ) CLERK OF THE BOARD ) CARDIFFSANITATION DISTRICT ) 505 SOUTH VULCAN AVENUE ) ENCINITAS CA, 92024 ) THE mtGINAL OF THIS DOCUMENT 0 RECORDED ON OCT 22, 1999 DOOM MUi43ER 1999 - 0709199 GREGQtY J. SMITH, COUNTY RECORDER SAN DIEGO COlKFY RECORDER'S OFFICE TIME: 8:09 AN RELEASE OF COVENANTS REGARDING REAL PROPERTY: PUBLIC SEWER IMPROVEMENTS REQUIRED IN CONSIDERATION OF FINAL APPROVAL OF CERTAIN RELATED SUBDIVISIONS Assessor's Parcel No: Case #: various 264- 240 -02.03 Drawing #: various Permit #: various DCS Work Order #: various DCS Christopher S. Lloyd, in all, and Gregory Cleary, in part, subdividers, having entered into covenants for the benefit of the Cardiff Sanitation District ( "DISTRICT" hereinafter) which were recorded with the County Recorder of San Diego County, all as follows: Document Date Description Case Drawine 1991- 201875 05/02/91 annexations ... 87- 041TM, 92- 035TPM, 92- 212TPM, 93- 029TM, 93- 053TPM, 97- 100TM, KI,97 -219TM main, laterals, appurtenances 92 -035 TPM CS -146 1994- 655404 11/10/94 main, laterals, appurtenances 93 -053 TPM CS -169 1996- 207398 04/25/96 main, laterals, appurtenances 93 -029 TM CS -202, and DISTRICT having determined that the obligations as set forth in said covenants have been fully and satisfactorily completed, DISTRICT hereby releases said covenants. Dated 1'ZO—gl ADA/jsg/re1L1oyd2.doc I CITY OF ENCINITAS by 44J 6, &" Alan D. Archibald, P.E. Director of Engineering Services (Notarization required) CALIFORNIA ALL - PURPOSE ACKNOWLEDGMENT State of 9411 _� County of a ,t 10 SSE r On `�� 1'7"9!? before met 10,4 • �r //-cjv ur;,u�e y Pu 6uc Doh ,,✓✓11 ��ii.r Nor and re. d Oee� I. t. -.Me oo NByn PuEff) personalty appeared ri�nt 111,6/%LD , .)y a sir".) rsonally known to me – OR – ❑proved to me on the basis of hsfactory evidence to be the person(s) whose name(sre subscribed to the within instrument and acknowledged to me that )P eJthey executed the 3agra i hi rRheir authorized capacity(ies), and that by OFFICIAL SEAL N dtheir signature(s) on the instrument the person(s), RANDA G. C-C LI OUR a or the entity upon behalf of which the person(s) acted, • - NOTARY PUBLIC�CAUFORNIA�g COMM, NO. 1204250 executed the Instrument SAN DIEGO COUNTY " MY COMM. EXP. JAN. 6, 2003 WITNESS my hand and official seal, sy.... d wet OPTIONAL T?w gh the nlonmarlon below a not reglired by law, x may prove vaArable lo penrwu re/yM m the docu nenr erd could prevent haudA" rernovW and manach neat of N ws rwm b anoMw don.nerit Description of Attached Document Title or Type of Document: Document Date: Signer(s) Other Than Named Above: Capacity(ies) Claimed by Signer(s) Signer's Name: ❑ Cl Individual Corporate Officer Tde(s): Partner — ❑ Limited Atlomey -in -Fact Trustee ❑ General Guardian or Conservator Other. Signer Is Representing: RIGHT THUhIBPRIN7 OF SIGNER Number of Pages: Signer's Name: O Individual El Corporate Officer Title(s): Partner —❑ Limited Attomey -in -Fad Trustee ❑ General ❑ Guardian or Conservator ❑ Other. Signer Is Representing: RIGHT TNUNBPRINT OF SIGNER '0 1994 Nabonal NObq Assn Alton • 82M Rermel Ave PO Boa 7184 - Canoga PaA CAI I M9 21 Ba P,W No 5907 Re., Call TOM Flee 1800 -$76 6WT PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858) 259 -8212 FAX (858) 259 -4812 July 24, 2000 City of Encinitas Engineering Services Permits 505 So. Vulcan Avenue Encinitas, CA 92024 WAYNE A. PASCO R.C.E. 29577 'p Lf��p JUL 2 4 70 I �i RE: ENGINEER'S PAD CERTIFICATION FOR PARCEL 1 OF PROJECT NO.97 -201TM AND GRADING PERMIT NO. 5452-G Pursuant to section 23.24.3 10 of the Encinitas Municipal Code, this letter is hereby submitted as a Pad Re- certification Letter for Parcel 1. As the Engineer of Record for the subject project, I hereby state the rough grading for this parcel has been completed in conformance with the approved plan and requirements of the City of Encinitas, Codes and Standards. 23.24.310(B). The following list provides the pad elevations as field verified and shown on the approved grading plan: Pad Elevation Pad Elevation Lot No. en r plan per field measurement 1 259.0 259.8 If you have any questions in regards to the above, please do not hesitate to contact this office. Very truly yours, PASCO ENGINEERING, INC. _ 9Joe Yuhas, L.S. 5211 �v O N -� Director of Land Surveying No. 5211 JY /js * EXn 3$GO �`CI,F ���P' PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858) 259 -8212 FAX(858)259 -4812 July 10, 2000 City of Encinitas Engineering Services Permits 505 So. Vulcan Avenue Encinitas, CA 92024 PE 718 WAYNE A. PASCO R.C.E. 29577 RE: ENGINEER'S PAD CERTIFICATION FOR LOT 2 OF PROJECT NO. 97- 201TM AND GRADING PERMIT NO 5452 -G Pursuant to section 23.24.310 of the Encinitas Municipal Code, this letter is hereby submitted as a Pad Certification Letter for lot 2. As the Engineer of Record for the subject project, I hereby state the rough grading for the lot have been completed in conformance with the approved plan and requirements of the City of Encinitas, Codes and Standards. 23.24.310(B). The following list provides the pad elevations as field verified and shown on the approved grading plan: Pad Elevation Pad Elevation Lot No. Per pl an per field measurement 2 271.0 270.8 23.24.310(B) 1. Construction of line and grade for all engineered drainage devices and retaining walls, have been field verified and are in substantial conformance with the subject grading plan. 23.24.310(B)5. The location and inclination of all manufactured slopes have been field verified and are in substantial conformance with the subject - grading plan. 23.24.310(B)6. The construction of earthen berms have been field verified and are in substantial conformance with the subject grading plan. If you have any questions in regards to the above, please do not hesitate to contact this office. Very truly yours, PASCO ENGINEERING, INC. oe Ytilias, L.S. 5211 Director of Land Surveying JY /js C. o "I, No. 5211 pr. ao- PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858)259 -8212 FAX (858) 259 -4812 June 27, 2001 City of Encinitas 505 So. Vulcan Avenue Encinitas, CA 92024 Attn: Todd Baumbach PE 718C RE: AS GRADED CERTIFICATION (GRADING PLAN NO. 5452 -G) Dear Mr. Baumbach: WAYNE A. PASCO R.C.E. 29577 Please be advised that the grading under permit no 5452 -G has been preformed in substantial conformance with the approved grading plan prior to sale of the lots. Please be advised that as of this date the homeowners have modified the pad grading for the installation of pools and individual landscaping desires. Should you have any questions or comments regarding the above, please do not hesitate to contact this office. Very truly yours, PASCO ENGINEERING, INC. Joe uh. 5211 Director of Land Surveying JY /js /c`"" QN C. y ltuZ `'� Ly IU 'O v m. 5211 PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858) 259 -8212 FAX(858)259 -4812 May 17, 2000 City of Encinitas Engineering Services Permits 505 So. Vulcan Avenue Encinitas, CA 92024 PE 718 RE: ENGINEER'S PAD CERTIFICATION FOR PROJECT NO. 97 -201TM AND GRADING PERMIT NO 5452 -G WAYNE A. PASCO R.C.E. 29577 Pursuant to section 23.24.3 10 of the Encinitas Municipal Code, this letter is hereby submitted as a Pad Certification Letter for lots 1 through and including 4. As the Engineer of Record for the subject project, I hereby state the rough grading for the lots have been completed in conformance with the approved plan and requirements of the City of Encinitas, Codes and Standards. 23.24.310(B). The following list provides the pad elevations as field verified and shown on the approved grading plan: 23.24.310(B) I. Construction of line and grade for all engineered drainage devices and retaining walls, have been field verified and are in substantial conformance with the subject grading plan. 23.24.310(B)5. The location and inclination of all manufactured slopes have been field verified and are in substantial conformance with the subject - grading plan. Pad Elevation Pad Elevation Lot No. Per plan per field measurement 1 259.0 259.0 2 271.0 271.0 3 upper 316.0 316.0 3lower 313.0 313.0 4 317.0 317.0 23.24.310(B) I. Construction of line and grade for all engineered drainage devices and retaining walls, have been field verified and are in substantial conformance with the subject grading plan. 23.24.310(B)5. The location and inclination of all manufactured slopes have been field verified and are in substantial conformance with the subject - grading plan. 23.24.310(B)6. The construction of earthen berms and positive building pad drainage have been field verified and are in substantial conformance with the subject grading plan. If you have any questions in regards to the above, please do not hesitate to contact this office. Very truly yours, PASCO ENGINEERING, INC. 0 - hly``QHC ryRe Joe Yuhas, L.S. 5211 44; o N Director of Land Surveying No. 5211 JY /js li r: PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858) 259 -8212 FAX (858) 259 -4812 March 23, 2000 City of Encinitas Engineering Services Permits 505 So. Vulcan Avenue Encinitas, CA 92024 PE 71 8M RE. ENGINEER'S PAD CERTIFICATION FOR PROJECT NO.97 -201TM AND GRADING PERMIT NO 5452 -G WAYNE A. PASCO R.C.E. 29577 Pursuant to section 23.24.3 10 of the Encinitas Municipal Code, this letter is hereby submitted as a Private Road and Driveway Certification Letter for subgrade. As the Engineer of Record for the subject project, I hereby state the rough grading for the Private Road and Drives has been completed in conformance with the approved plan and requirements of the City of Encinitas, Codes and Standards. If you have any questions in regards to the above, please do not hesitate to contact this office. Very truly yours, PASCO ENGINEERING, INC. Joe Yuhas, L.S. 5211 Director of Land Surveying N NN S JY /js �U O N No. 5211 \* EX P 3c 23 VINJE & MIDDLETO,. ENGINEER Job #99 -390 -F May 26, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 , INC. 2450 Vineyard Avenue, #102 Fkondido, California 92029 -1229 Phone(760)743.1214 Fax (760) 739.0343 ADDENDUM TO PREVIOUSLY ISSUED AS- GRADED COMPACTION REPORT DATED JANUARY 17, 2000 FOR PARCEL #3, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201. LOCATED OFF DOUBLE LL RANCH ROAD Indications of adverse soil condiltions after last winters rains were evident on this lot. Therefore the upper six inches was scarified, moisture conditioned to near optimum moisture content and recompacted. Field density tests were conducted in accordance with ASTM Method D- 1556 -90 sand cone method as the upper 6 inches was recompacted. The results of our field density tests and laboratory testing indicate that the recompacted upper 6 inches was compacted to at least 90 %, and this Parcel is now properly prepared for construction. All recommendations put forth in our January 17, 2000 "As- Graded" report for this Parcel should be adhered to. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING. INC. Vinje GE #863 RMV /MS /mpr �0 Fey\ m m c Em 1231 OF Aui lc�l Mehdi Shariat RCE #46174 Distribution: Addressee (6) d R mprV wntL&390.f.tt3 � 1►� . e iwv, D miner. r+rNG SciViCES CITY 0 F E qC;n1ILgS No.46174 * EXK 1231 -02 P4 C VINJE & MIDDLEM, ENGINEERING, INC. 1 � • r • 4K.0I1119 May 26, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax(760)739 -0343 MAY2a3 D ADDENDUM TO PREVIOUSLY ISSUED FOUNDATION RECOMMENDATIONS REPORT DATED JANUARY 17, 2000 FOR PARCEL #4, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201. LOCATED OFF DOUBLE LL RANCH ROAD Indications of adverse soil conditions after last winters rains are presently not evident on this lot. Therefore, all recommendations put forth in our January 17, 2000 "Foundation Recommendations Report" for this Parcel should be adhered to. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON 0 GE #863 RMV /MS /mpr Distribution: Addressee (6) mpMllcont%99 -390.f U tuej RCE #46174 Landmark Engineering Corporation 2605 Del Rio South Camino Suite 321 San Dieeo, CA 92108 Phone (619) 260 -0420 Fax (619) 260 -0456 GEOGRID DESIGN CHART Project: TRES VISTA ESTATES Date: 2114 100 By: Lawrence E. Cole WALL (2:1 Slope) Exposed Wall Ht. Buried Wall Ht Grid Length Grig Location feet from Bottom of Wall Strata 200 3.33 .67 M60 none none 5.33 .67 6.00 2.00, 4.00 7.33 .67 7.00 2.00 4.00 6.00 Lawrence E. Cole RCE 36 92 exp. 630/00 FEB�� � ; fESSIp A; y 4 ((-Tmo. 36292 f'!4 C I V 1 ��P 11 OF CAl \FOP BROW DITCH PER GRADING PLAN 4" OR B" CAP UNIT COMPAC UNIT STANDARD UNIT FINISH GRADE =1111 =1111°IIII= III/ SEE %4� om VIM Iii %mil //1 =0I I/ /,moorr ®11 WAS k SLOpE =IM FILTER FABRIC (TYP.) GEOGRIDS BACKFILL SHALL MEET OR EXCEED 117 lbs. UNIT WEIGHT WITH A SOIL FRICTION ANGLE ;g' = 36• COMPACT TO 90 PERCENT PER ASTM D -1557 4" PERFORATED DRAIN PIPE TO DRAIN ® 1% MIN. (SEE DETAIL) 314" CRUSHED AGGREGATE (6" A/IN.) L GRID SEE GEOGRIO CHART FOR LENGTH AND SPACING TYPICAL SECTION NO SCALE CONTRACTOR TO ALTERNATE PINS FOUNDATION SHALL MEET OR EXCEED 117 lbs. UNIT WEIGHT WITH A SOIL FRICTION ANGLE p = 36° RETAINED SHALL MEET OR EXCEED 117 lbs. UNIT WEIGHT WITH A SOIL FRICTION ANGLE NNo. 36292 ! p vl3��v� Jl CIV!� �\P OF page I of 3 KEYSTONE RETAINING WALL DESIGN Based on Coulomb -NCMA (modified soil interface) Methodology KeyWall Ver 1b, Oct 1, 1997 Geogrid Retaining Wall Sys. Project: Tres Vista Estates Proj. No.: 1826 Design Parameters Soil Parameters -L —R.21 Yom, ocf Reinforced Fill: 36 0 117 Retained Fill: 36 0 117 Foundation Fill: 36 0 117 Reinforce Fill Type: Silts 8 sands Unit Fill: Crushed Stone, 1 inch minus Factors of Safety Sliding: 1.50 Pullout: 1.50 Connection Analysis: Gravity Section Date: 2115100 By: LEC Overturning: 2.00 Uncertainties: 1.50 Bearing: 2.00 Peak: 1.50 ServiceabiliN /A Unit Type: STANDARD (21.5 in) Wall Batter: 6.30 deg. Leveling Pad: Crushed Stone Wall Ht: 4.00 ft embedment: 0.67 ft BackSlope Geometry: 26.60 deg. slope 10.00 ft high Surcharge: LL .0 psf uniform surcharge DL -- 0 psf uniform surcharge Results: Sliding Overturning Bearing Shear Bending Factors of Safety: 3.58 2.71 19.50 N/A N/A Calculated Bearing Pressure: 516 psf Eccentricity at base: 0.19 ft p'FESSroy� CCC No. 36292 � d eyl u c;. S C1 V1\- l4?, OF CAL \4�� Keystone Retaining Wall Systems, Inc. 4444 West 78th Street Minneapolis, MN 55435 page ? of 3 KEYSTONE RETAINING WALL DESIGN Based on Coulomb -NCMA (modified soil interface) Methodology KeyWall Ver 1b, Oct 1, 1997 Geogrid Retaining Wall Sys. Project: Tres Vista Estates Proj• No.: 1826 Design Parameters Soil Parameters c Dsf ocf Reinforced Fill: 36 0 117 Retained Fill: 36 0 117 Foundation Fill: 36 ❑ 117 Reinforce Fill Type: Silts 8 sands Unit Fill: Crushed Stone, 1 inch minus Factors of Safety Sliding: 1.50 Pullout: 1.50 Connection Date: 2/15/00 Bv: LEC Overturning: 2.00 Uncertainties: 1.50 Bearing: 2.00 Peak: 1.50 ServiceabiliN /A Reinforcing Parameters: Strata -Grid Geogrids Tult RFcr RFd RFid LTDS FS Tal C Cds Strata -200+ 2416 1.61 1.10 1.10 1241 1.50 827 1.00 1.00 Analysis: 6' Section Unit Type: STANDARD (21.5 in) Wall Batter: 6.30 deg. Leveling Pad: Crushed Stone Wall Ht: 6.00 ft embedment: 0.67 ft BackSlope Geometry: 26.60 deg. slope 10.00 ft high Surcharge: LL •0 psf uniform surcharge DL -- 0 psf uniform surcharge Results: Sliding Overturning Bearing Shear Bending Factors of Safety: 3.19 5.35 20.61 7.71 21.71 Calculated Bearing Pressure: 818 psf Eccentricity at base: 0.32 ft Reinforcing: (ft 8 lbs /ft) Laver Height Length Reinf• Tal Tension Tconn FS22 2 4.00 6.00 Strata -200+ 607 144 607 s 5.88 1 2.00 6.00 Strata -200+ 827 433 864 5.68 Reinforcing Quantities (no waste included)( Efficiency= 35% Strata -200 +: 1.33 sy /ft No. 36292 e* IV, laolon J' CI p 1� *P, Keystone Retaining Wall Systems, Inc. 4444 West 78th Street Minneapolis, MN 55435 page 3 of 3 KEYSTONE RETAINING WALL DESIGN Based on Coulomb -NCMA (modified soil interface) Methodology KeyWall Ver lb, Oct 1, 1997 Geogrid Retaining Wall Sys. Project: Tres Vista Estates Proj. No.: 1826 Design Parameters Soil Parameters Al c osf _Y ocf Reinforced Fill: 36 0 117 Retained Fill: 36 0 117 Foundation Fill: 36 0 117 Reinforce Fill Type: Silts & sands Unit Fill: Crushed Stone, 1 inch minus Factors of Safety Sliding: 1.50 Pullout: 1.50 Connection Date: 2/15/00 Overturning: 2.00 Uncertainties: 1.50 Bearing: 2.00 Peak: 1.50 ServiceabiliN /A Reinforcing Parameters: Strata -Grid Geogrids Strata -200+ 2418 1.61 1.10 1.10 1241 1.50 827 1.00 1.00 Analysis: 8' Section Unit Type: STANDARD (21.5 in) Wall Batter: 6.30 deg. Leveling Pad: Crushed Stone Wall Ht: 8.00 ft embedment: 0.67 ft BackSlope Geometry: 26.60 deg. slope 10.00 ft high Surcharge: LL 0 psf uniform surcharge DL -- 0 psf uniform surcharge Results: Sliding Overturning Bearing Shear Bending Factors of Safety: 2.87 4.31 16.14 5.74 21.71 Calculated Bearing Pressure: 1136 psf Eccentricity at base: 0.54 ft Reinforcing: (ft & lbs /ft) Laver Height Length Reinf. Tal Tension Tconn FSoo 3 6.00 7.00 Strata -200+ 607 144 607 s 4.75 2 4.00 7.00 Strata -200+ 827 257 864 9.08 1 2.00 7.00 Strata -200+ 827 625 1075 7.54 Reinforcing Quantities (no waste included)( Efficiency= 41% ) Strata -200 +: 2.33 sy /ft f 36292 i,J_ clJ c �IV Q \ Keystone Retaining Wall Systems, Inc. 4444 West 78th Street Minneapolis, MN 55435 VINJE & MIDDLETON FTNGINEERING, INC. Job #99 -390 -F January 17, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, +x102 Escondido, California 92029.1229 Phone(760)743 -1214 Fax (760) 739 -0343 p R II" D MAY 2 5 2100 ENGINEERING SERVICES CITY OF ENCINITAS AS- GRADED COMPACTION REPORT AND FOUNDATION RECOMMENDATIONS FOR PARCEL #3, AND COMMON DRIVEWAY TO PARCEL #4, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201 LOCATED OFF DOUBLE LL RANCH ROAD In accordance with the Grading Ordinance for the City of Encinitas, this as- graded compaction report has been prepared for the above referenced project. We have completed engineering observation and testing services in conjunction with the grading operations. This report summarizes the results of our tests and observations of the compacted fills. The compacted fills in the subject areas were placed periodically from February 2, 1999, though August 2, 1999. Actual dates are shown on the enclosed compaction test result sheets. 7�� •-L •� -• G.d • Grading plans for this project were prepared by Pasco Engineering. The following listed reports were reviewed by this office as part of this project: A. "Preliminary Geotechnical Investigation Proposed 5 Parcel Subdivision" report prepared by this office, dated May 27, 1998, Job #97- 145 -V. B. "Clarification Letter On Preliminary Geotechnical Investigation Report" prepared by this office, dated April 28, 1998, Job #97- 145 -V. C. "Response to Consultant Review of Preliminary Geotechnical Investigation, Proposed 5 Parcel Subdivision" letter prepared by this office, dated August 11, 1998, Job #97- 145 -V. D. "Updated Preliminary Geotechnical Investigation Report and Grading Plan RevievJ' letter prepared by this office, dated December 21, 1998, Job #97- 145 -V. As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 2 Prior to grading operations, the site was cleared of vegetation. All questionable loose and compressible soils were also removed from the areas receiving fill. Adequate keys or benches were constructed a minimum of 2 feet into firm, undisturbed natural ground or formational soils prior to fill placement. The upper pad is a "cut' pad. As no fill was placed on this pad, no field density testing was conducted. The lower pad is a "cut/fill" pad, and the cut portion of the pad was undercut a minimum of 3 feet and replaced as a structural fill, decreasing the potential for concrete cracking along the daylight (cuttfill) line. Due to the close proximity of the lower pad to the open space easement, no combustible structures may be placed on this pad. Recommendations can be made when the type of "non combustible" structure to be placed on this lower pad, is known Site preparation and grading were conducted in substantial conformance with the Grading Ordinance for City of Encinitas and our above listed preliminary and update geotechnical report. All inspections and testing were conducted under the observation of this office. In our opinion, all embankments and excavations were constructed in substantial conformance with the provided grading plan, and are acceptable for their intended use. II. FILL PLACEMENT Fill was placed in six to eight inch lifts and compacted by means of heavy construction equipment. Field density tests were performed in accordance with ASTM Method D -1556- 90 sand cone method as the fill was placed. The moisture content for each density sample was also determined. The approximate locations of the field density tests are shown on the attached drawing. The locations of the tests were placed to provide the best possible coverage. Areas of low compaction, as indicated by the field density tests, were brought to the attention of the contractor. These areas were reworked by the contractor and retested. The test locations and final test results are summarized on the compaction test result table. The results of our field density tests and laboratory testing indicate that the fills at the site were compacted to at least 90% of the corresponding maximum dry density at the tested locations. If the building pad should undergo any seasonal wetting and drying periods prior to construction, remedial grading could be required depending on the site soil characteristics. Depths of removal and recompact can best be determined just prior to construction by appropriate inspection and testing. VINJE 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, 0102, Escondido, C.Ii(ornia 92029-1229 • Phane (760) 743 -1114 • Fax (760) 739.0343 QEOTECHNICAL INVESTIQATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIQATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 3 III. APPROPRIATE LABORATORY TESTS A. Maximum Dry Density Optimum Moisture Tests: The maximum dry density and optimum moisture contents of the different soil types used as compacted fill were determined in accordance with ASTM Method D- 1557 -91. B. Expansion Tests: Expansion tests were conducted per 1994 UBC Standard Procedure 18 -2 on representative samples of the mixture of on site soils used in the pad construction to determine the expansion potential and to provide appropriate foundation recommendations. C. Direct Shear Tests: Direct shear tests were performed on representative samples of the mixture of on site soils used in pad construction to determine the allowable bearing capacity and to provide retaining wall design parameters. IV. RECOMMENDATIONS UPPER "CUT" PAD ONLY The following minimum foundation recommendations for very expansive (Expansion Index = Less Than 20) soils, classified using the "Unified Soil Classification System or USCS" as SM, should be adhered to, incorporated into the foundation plans. It is suggested that the foundation plans be submitted to our office for review and approval prior to construction. Please note ( * *) items for revised recommendations since the issuance of our original preliminary report. A. Foundations and Slab -on -Grade Monolithic Pour System 1. Continuous strip foundations should be a minimum of 12 inches wide by 12 inches deep, and 15 inches wide by 18 inches deep for one and two story structures respectively. Spread pad footings should be at least 24 inches by 24 inches wide and 12 inches deep, for one and two story structures. Minimum depths are measured from the lowest adjacent ground surface, not including the sand under the slab. Exterior continuous footings should enclose the entire building perimeter, to include the garage entryway. 2. Use four #4 reinforcing bars in all interior and exterior stud bearing wall footings. Place two bars 3 inches below the top of the footing, and two bars 3 inches above the bottom of the footing. Reinforcement for isolated square footings should be designed by the project structural engineer. VIN1E B MIDDLEFON ENQINEERING, INC. 2450 Vineyard Avenue, #102, Escondido, C fifo is 92029.1229 • Phone (760) 743 "1214 • F. (760) 739.0343 QEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 4 3. All interior slabs must be a minimum of 4 inches in thickness reinforced with #3 reinforcing bars spaced 18 inches on center each way, placed midheight in the slab. Use 4 inches of clean sand (SE 30 or greater) beneath all slabs. A six -mil plastic moisture barrier must be placed midheight in the sand. Provide re- entrant (±2700 corners) reinforcement for all interior slabs as generally shown on the enclosed "Isolation Joints and Re- Entrant Corner Reinforcement' detail. Re- entrant corners will depend on slab geometry and/or interior column locations. 4. The minimum steel reinforcement provided herein is based on soil characteristics only, and is not intended to be in lieu of reinforcement necessary for structural considerations. 5. Provide contraction joints consisting of sawcuts spaced 10 feet on center each way within 24 hours of concrete pour for all interior slabs. The sawcuts must be a minimum of % inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. 6. All underground utility trenches beneath interior and exterior slabs should be compacted to a minimum of 90% of the maximum dry density of the soil. Care should be taken not to crush the utilities or pipes during the compaction of the trench backfill. 7. Exterior Flatwork and Driveways: a) Walkways, patios, etc. must be a minimum of 4 inches in thickness reinforced with 6x6 /10x10 welded wire mesh carefully placed two inches below the top of the slab. Provide contraction joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The sawcuts must be a minimum of 9/4 inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. ** b) Concrete driveways and parking areas should consist of 5 inch thick concrete reinforced with #3 reinforcing bars spaced 18 inches on center each way placed two inches below the top of the slab. The concrete should be placed over 6 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. Provide contraction joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The depths of the sawcuts should be as described in Item #a) above. VINJE ® MIDDLETON ENGINEERINQ, INC. 2450 Vineyard Avenue, #102, Escondido, California 92029 -1229 • Phone (760) 743 -1114 • Fax (760) 739 -0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 5 «« c) Asphalt concrete (AC) driveways and parking areas should consist of 3 inches AC over 6 inches Cal Trans Class II aggregate base compacted to a minimum of 95% over 6 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. Unless requested, recommendations for a future swimming pool or spa were not included in this report. Prior to their construction this office should be contacted to update conditions and provide additional recommendations. 8. This office is to be notified to inspect or test the following prior to foundation concrete pours: a) Inspect the plumbing trenches beneath slabs after the pipes are laid and prior to backfilling. b) Test the plumbing trenches beneath slabs for minimum compaction requirements. c) Inspect the footing trenches for proper width, depth, reinforcing size and placement. Inspect the slabs for proper thickness, reinforcing size and placement, sand thickness and moisture barrier placement. 9. The following allowable foundation and lateral pressures maybe used for design of foundations on certified soils for structures which have continuous footings having a load of less than 2,000 plf and isolated footings with loads of less than 50,000 lbs. a) Our tests and calculations indicate that an allowable bearing capacity of 2,000 psf for continuous and isolated footings may be used. The allowable soil bearing pressure provided herein is for dead plus live loads and may be increased by one -third for wind and seismic loading. b) The allowable soil bearing pressure provided herein was determined for footings having a minimum width of 12 inches and a minimum depth of 12 inches below the lowest adjacent ground surface. This value may be increased per Uniform Building Code for additional width and depth if needed. c) An allowable lateral bearing pressure of 150 psf per foot of depth may also be used for all structures except retaining walls. The lateral bearing earth VINJE H MIDDLETON ENQINEERING, INC. 2450 Vineyard Avenue, #102, Escondido, CaG(mma 920291229 • Phmw (760) 743 -1114 • Fax (760) 739.0343 GEOTECHNICAL INVESTIGATIONS QRADINQ SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 6 pressure may be increased by the amount of the designated value for each additional foot of depth to a maximum of 1,500 psf. B. Retaining Walls. Lateral Load Parameters 1. The following earth pressures based on the finish grade very low expansive "cut" soils, should be used for design of retaining walls: a) Use a friction angle of 38 degrees. b) Use a wet density of 118 pcf. c) Use a coefficient of friction of 0.40 for concrete on soil. d) Use an active pressure of 29 pcf equivalent fluid pressure for cantilever, unrestrained walls with level backfill surface. e) Use a active pressure of 42 pcf equivalent fluid pressure for cantilever walls with a 2:1 (horizontal to vertical) backfill. f) Use an at rest pressure of 46 pcf equivalent fluid pressure for restrained walls. g) Use a passive resistance of 400 pcf equivalent fluid pressure for level surface condition at the toe. h) Use an allowable bearing capacity of 2,000 psf as described above. 2. Expansive clayey soils should not be used for backfilling of any retaining walls. Retaining walls should maintain at least a 1:1 (horizontal to vertical) wedge of granular non -expansive soil backfill measured from the base of the wall footing to the ground surface. All retaining walls should be provided with a drain along the backside as generally shown on the enclosed "Retaining Wall Drain" detail. Specific drainage provisions behind retaining wall structures must be inspected by this office prior to backfilling the wall. All backfill soils must be compacted to a minimum of 90% of the corresponding maximum dry density, ASTM 1557 -91. Note: Because large movements must take place before maximum passive resistance can be developed, use a minimum safety factor of 2.0 for wall sliding VINIE B MIDDLETON ENCIINEERING, INC. 2450 Vineyard Awnue, #102, Escondido, California 92029/229 • Phunc (760) 743.1114 • Fax (760) 739 -0343 QEOTECHNICAL INVESTIGATIONS QRAOINQ SUPERVISION PERC TESTING ENVIRONMENTAL INVESfIQATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 7 stability where structures or improvements are planned near or adjacent to the top of the wall. When combining passive and frictional resistance, the passive component should be reduced by one - third. 3. The planting of large trees behind any retaining wall will adversely affect their performance and should be avoided. C. Seismic Coefficients The following site specific seismic parameters for the above referenced project were determined in accordance with the Uniform Building Code requirements. The following parameters are consistent with the indicated project seismic environment and may be utilized for project design work. According to Chapter 16, Division IV of the 1997 Uniform Building Code D. Setbacks 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. 2. The outer edge of all slopes experience "down slope creep ", which may cause distress to structures. If any structures including buildings, patios, sidewalks, swimming pools, spas etc, are placed within the setback, FURTHER RECOMMENDATIONS WILL BE REQUIRED. Expansive soils can cause structural damage to foundations, interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. VIN1E B MIDDLETON EN(;TNEERINQ, INC. 2450 Vineyard Aswnue, •102, Escondido, California 910291219 • Phonc (760) 743 -1114 • Fax (760) 739-0343 CEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERCTESTING ENVIRONMENTAL INVESTIGATIONS Seismic Response Coefficients Site Soil Seismic Seismic Na Nv Ca Cv Ts To Profile Seismic Zone Source Type Zone Factor Type Sc 4 0.4 B 1.0 1.0 0.40 0.56 0.560 0.112 According to Chapter 16, Division IV of the 1997 Uniform Building Code D. Setbacks 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. 2. The outer edge of all slopes experience "down slope creep ", which may cause distress to structures. If any structures including buildings, patios, sidewalks, swimming pools, spas etc, are placed within the setback, FURTHER RECOMMENDATIONS WILL BE REQUIRED. Expansive soils can cause structural damage to foundations, interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. VIN1E B MIDDLETON EN(;TNEERINQ, INC. 2450 Vineyard Aswnue, •102, Escondido, California 910291219 • Phonc (760) 743 -1114 • Fax (760) 739-0343 CEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERCTESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 8 "A COPY OF THIS REPORT MUST BE PROVIDED TO THE PROJECT ARCHITECT /STRUCTURAL ENGINEER TO ENSURE THE THE ABOVE FOUNDATION RECOMMENDATIONS ARE INCLUDED IN APPROPRIATE PLANS" The concrete reinforcement recommendations provided herein should not be considered to preclude the development of shrinkage related cracks, etc.; rather, these recommendations are intended to minimize this potential. If shrinkage cracks do develop, as is expected from concrete, reinforcements tend to limit the propagation of these features. These recommendations are believed to be reasonable and in keeping with the local standards of construction practice. Special attention should be given to any "re- entrant' corners ( ±270 degree corners) and curing practices during and after concrete pour in order to further minimize shrinkage cracks. E. Slopes All slopes should be landscaped with types of plants and planting that do not require excessive irrigation. Excess watering of slopes should be avoided. Slopes left unplanted will be subject to erosion. The irrigation system should be installed in accordance with the governing agencies. Water should not be allowed to flow over the slopes in an uncontrolled manner. Until landscaping is fully established, plastic sheeting should be kept accessible to protect the slopes from periods of prolonged and/or heavy rainfall. Berms should be constructed along the top edges of all fill slopes. In no case should water be allowed to pond or flow over slopes. Brow ditches should be constructed along the top of all cut slopes sufficient to guide runoff away from the building site and adjacent fill slopes prior to the project being completed. F. Drainage The owner /developer is responsible to insure adequate measures are taken to properly finish grade the building pad after the structures and other improvements are in place so that the drainage waters from the improved site and adjacent properties are directed away from proposed structures in accordance with the designed drainage patterns shown on the approved plans. VIN3E B MIDDLErON ENGINEERING, INC. 2450 Vineya.d Awnue, #102, Escondido, Ca®fo is 920294229 • Phone (760) 743 -1214 • Fax (760) 739.0343 QEOTECBNICAL INVESTIGATIONS GRA IKSLIPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 9 A minimum of two percent gradient should be maintained away from all foundations. Roof gutters and downspouts should be installed on the building, all discharge from downspouts should be led away from the foundations and slab to a suitable location. Installation of area drains in the yards should also be considered. Planter areas adjacent to foundations should be provided with damp /water proofing, using an impermeable liner against the footings, and a subdrainage system within the planter area. It should be noted that shallow groundwater conditions may still develop in areas where no such conditions existed prior to site development. This can be contributed to by substantial increases of surface water infiltration resulting from landscape irrigation which was not present before the development of the site. It is almost impossible to absolutely prevent the possibility of shallow groundwater on the entire site. Therefore, we recommend that shallow groundwater conditions be remedied if and when they develop. The property owner should be made aware that altering drainage patterns, landscaping, the addition of patios, planters, and other improvements, as well as over irrigation and variations in seasonal rainfall, all affect subsurface moisture conditions, which in turn affect structural performance. 1KC390114,'T,1 �] �T3iI�I►1 It should be noted that the characteristics of as- compacted fill may change due to post - construction changes from cycles of drying and wetting, water infiltration, applied loads, environmental changes, etc. These changes can cause detrimental changes in the fill characteristics such as in strength behavior, compressibility behavior, volume change behavior, permeability, etc. The owner /developer should be made aware of the possibility of shrinkage cracks in concrete and stucco materials. The American Concrete Institute indicates that most concrete shrinks about 'A inch in 20 feet. Separation between construction and cold joints should also be expected. The amount of shrinkage related cracks that occur in concrete slab -on- grades, flatwork and driveways depend on many factors, the most important of which is the amount of water in the concrete mix. The purpose of the slab reinforcement is to keep normal concrete VINJE 9 MIDDLETON ENCy1NEERINQ, INC. 2450 Vineyard Avenue, ♦102, Esc.dida, California 92029.1229 • Ph.. (760) 7431214 • Fax (760) 739 -0343 QEOTECHNICAL INVESfIQATIONS QRADINQ SUPERVISION PERC TESTINQ ENVIRONMENTAL INVESCIQATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 10 shrinkage cracks closed tightly. The amount of concrete shrinkage can be minimized by reducing the amount of water in the mix. To keep shrinkage to a minimum, the follow ng should be considered: A. Use the stiffest mix that can be handled and consolidated satisfactorily. B. Use the largest maximum size of aggregate that is practical, for example concrete made with 3/a inch maximum size aggregate usually requires about 40 pounds (nearly 5 gallons) more water per cubic yard than concrete with 1 inch aggregate. C. Cure the concrete as long as practical. The amount of slab reinforcement provided for conventional slab -on -grade construction considers that good quality concrete materials, proportioning, craftsmanship, and control tests where appropriate and applicable are provided. This office is to be notified no later than 2 p.m. on the day before any of the following operations begin to schedule appropriate testing and /or inspections. A. Fill placed under any conditions 12 inches or more in depth, to include: 1. Building pads. 2. Street improvements, sidewalks, curbs and gutters. 3. Utility trench backfills. 4. Retaining wall backfills. 5. The spreading or placement of soil obtained from any excavation (footing or pool, etc.). B. Inspection and testing of subgrade and basegrade beneath driveways, patios, sidewalks, etc., prior to placement of pavement or concrete. C. Moisture testing. D. Foundation inspections. E. Any operation not included herein which requires our testing, observation, or inspection for certification to the appropriate agencies. VINIE ® MIDDLElON ENGINEERINQ, INC. 2450 Vineya.d Aw.,, #102, Escondido, Ca9(arnia 92029.1219 • Pha (760) 7431214 • Fax (760) 739.0343 QEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING EM'IRONMENTAL INVESTIGATIONS As- Graded Compaction Report, Parcel #3, Encinitas TM #97 -201 January 17, 2000 Page 11 VI. LIMITATIONS Our description of grading operations, as well as observations and testing services herein, have been limited to those grading operations performed periodically from February 2, 1999, though August 2, 1999. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. The attached drawing details the approximate locations of cuts, fills, and locations of the density tests taken and is applicable to the site at the time this report was prepared. This report should be considered valid for permit purposes for a period of six months and is subject to review by our firm following that time. IF ANY CHANGES ARE MADE, PAD SIZE, BUILDING LOCATION, ELEVATIONS, ETC. - THIS REPORT WILL BECOME INVALID AND FURTHER ENGINEERING AND RECOMMENDATIONS WILL BECOME NECESSARY. If you have any questions or need clarification, please contact this office at your convenience. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. Ralph M. Vinje i co 1 GE #863 RMV /MS /mpr t� °T� Distribution: Addressee (6) mprlfil Icc ntl49- 390-f.ag3 1• Esp. Mehdi Shariat RCE #46174 f4�.4617A � EYd? 12.31 -02 >t; �\ %yam CNII �P VINJE B MIDDLETON ENGINEERING. INC. 2450 Vineyard Avenue, #102, Escondido, California 92019/229 • Phone (760) 7431214 • 1. (760) 739 -0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERCTESTING ENVIRONMENTAL INVESTIGATIONS JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain LABORATORY COMPACTION TEST RESULTS PARCEL #3 AND COMMON DRIVEWAY TO PARCEL #4: Soil Type 1: Dark to Olive Brown Sandy to Silty Clay (Topsoils) Maximum Dry Density: 113.2 pcf Optimum Moisture: 15.5% Soil Type 2: Olive -Green to Grey Claystone (Bedrock) ** Maximum Dry Density: 111.3 pcf Optimum Moisture: 17.8% Soil Type 3: Tan to Brown Fine Grained Sandstone (Bedrock) ** Maximum Dry Density: 119.9 pcf Optimum Moisture: 112% Soil Type 6: Tan Sandy Clayey Silt Maximum Dry Density: 117.7 pcf Optimum Moisture: 14.8% * *From our "Preliminary Geotechnical Investigation" report dated May 27, 1997, Job #97 -145 -V mpr\fllcontic&- fpO JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Pad Construction, Parcel #3 and Common Driveway, to Parcel #4 Date 1999 Test No. Location El. Of Fill In Ft % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 02/24 1 Parcel 3 and 4, Driveway, Station 0 +60 249 29.8 96.8 113.2 85.5 UC 4, Keyway, Test Failed i 2 Parcel 3 and 4, Driveway, Station 0 +70 249 19.9 103.0 113.2 91.0 Retest #1 03/02 3 Parcel 3 and 4, Driveway, Station 0 +30 250 24.3 101.2 111.3 90.9 03/02 4 Parcel 3 and 4, Driveway, Station 1 +35 259 21.9 104.0 113.2 91.9 03/02 5 Parcel 3 and 4, Driveway, Station 1 +00 252 20.0 102.0 113.2 90.1 03/03 6 Parcel 3 and 4, Driveway, Station 0 +50 254 28.2 99.5 113.2 87.9 UC -3', Keyway, Test Failed 03/03 7 Parcel 3 and 4, Driveway, Station 3 +15 300 18.1 102.9 117.7 87.4 UC -2', Keyway, Test Failed 03/03 8 Parcel 3 and 4, Driveway, Station 0 +65 254 24.3 104.8 113.2 92.6 Retest #6 03/03 9 Parcel 3 and 4, Driveway, Station 3 +10 300 17.0 1071 117.7 91.1 Retest #7 03/04 10 Parcel 3 and 4, Driveway, Station 5 +05 304 23.0 103.7 113.2 91.6 03/04 11 Parcel 3 and 4, Driveway, Station 1 +25 256 16.9 107.0 117.7 90.9 12 Parcel 3 and 4, Driveway, Station 2 +31 283 21.8 101.1 111.3 90.8 03/04 13 Parcel 3 and 4, Dnveway, Station 4 +80 306 17.6 109.5 117.7 93.1 03/04 14 Parcel 3 and 4, Driveway, Station 5 +20 308 18.1 109.0 117.7 92.6 03/04 15 Parcel 3 and 4, Driveway, Station 5 +00 310 17.7 109.5 117.7 93.0 03104 16 Parcel 3 and 4, Driveway, Station 5 +60 306 17.4 108.8 117.7 92.4 UC -3', Keyway 03/04 17 Parcel 3 and 4, Driveway, Station 5 +50 308 16.9 108.3 117.7 92.0 03/04 18 Parcel 3 and 4, Driveway, Station 5 +40 310 20.8 102.1 113.2 90.2 03/04 19 Parcel 3 and 4, Driveway, Station 3 +90 307 17.8 109.0 117.7 92.6 UC -2', Keyway 03%04 20 Parcel 3 and 4, Driveway, Station 5 +15 312 16.6 107.8 117.7 91.6 03/04 21 Parcel 3 and 4, Driveway, Station 1 +23 261 155 101.9 113.2 90 0 JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Pad Construction, Parcel #3 and Common Driveway, to Parcel #4 Date 1999 Test No. Location El. Of Fill In FL % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 03/05 22 Parcel 3 and 4, Driveway, Station 2 +20 280 18.1 10310 113.2 91.0 i 23 Parcel 3 and 4, Driveway, Station 2 +75 295 17.4 109.0 117.7 92.6 03/05 24 Parcel 3 and 4, Driveway, Station 3 +30 304 18.2 106.8 117.7 90.7 03105 25 Parcel 3 and 4, Driveway, Station 6 +00 312 16.9 107.2 117.7 91.1 03/05 26 Parcel 3 and 4, Driveway, Station 4 +50 312 17.5 107.1 117.7 90.0 03/08 27 Parcel 3 and 4, Driveway, Station 6 +25 316 21.3 104.9 113.2 92.7 Remove and Re- Compact 2' 03/08 28 Parcel 3 and 4, Driveway, Station 7 +50 318 20.9 103.7 113.2 91.6 Finish Grade 03/08 29 Parcel 3 and 4, Driveway, Station 3 +95 310 20.0 1082 117.7 91.9 03/09 30 Parcel 3, Lower Pad 306 14.6 107.8 117.7 91.6 UC -2', Keyway 03/09 31 Parcel 3, Lower Pad 307 16.3 110.2 117.7 93.6 0 "r19 32 Parcel 3, Lower Pad 309 15.6 108.8 119.9 90.8 d 33 Parcel 3, Lower Pad 310 15.0 108.7 119.9 90.6 03/09 34 Parcel 3, Lower Pad 310 15.1 110.3 119.9 92.0 03/10 35 Parcel 3 & 4, Driveway, Station 3 +40 to 3 +80 314 13.3 108.1 119.9 90.2 Slope Repair 03/10 36 Parcel 3 & 4, Driveway, Station 3 +40 to 3 +80 316 13.9 109.8 119.9 91.5 Slope Repair 03/10 37 Parcel 3 and 4, Driveway, Station 1 +50 270 17.4 109.1 117.7 92.7 03/10 38 Parcel 3 and 4, Driveway, Station 1 +20 265 18.0 109.8 117.7 93.3 07/20 39 Parcel 3, Lower Pad 311 21.5 105.3 111.7 94.3 07/21 40 Parcel 3, Lower Pad 313 17.2 98.0 111.7 87.7 Finish Grade, Test Failed 07122 41 Parcel 3, Lower Pad 313 19.0 101.3 111.7 907 Retest #40 07;22 42 Parcel 3, Upper Pad, In Place Density, "Cut" 316 16.0 103.5 111 7 92 .7 Finish Grade JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Pad Construction, Parcel #3 and Common Driveway, to Parcel #4 U. Jndercut mprVillcontQ9-39D-f tr3 El. Field Lab Of % Dry Dry % FDa.te Fill In Field Density Density Relative Test Ft. Moisture Pcf Pcf Comp. Comments 9 No. Location 08;02 43 Parcel 3 & 4, Driveway, Station 1 +25 268 16.1 103 0 111.7 922 Finish Grade U. Jndercut mprVillcontQ9-39D-f tr3 ISOLATION JOINTS AND RE- ENTRANT CORNER REINFORCEMENT (a) Typical - no scale 4TI ON JOINTS 2ACTION JOINTS (C) (b) u RE- ENTRANT C( REINFORCEMEN' NO.4 BARS PL BELOW TOP OF NOTES: ENTRANT NER CRACK Isolation joints around the columns should be either circular as shown in (a) or diamond shaped as shown in (b). If no isolation joints are used around columns, or if the corners of the isolation joints do not meet the contraction joints, radial cracking as shown in (c)may occur (reference ACI). 2. In order to control cracking at the re- entrant corners ( ±2700 corners), provide reinforcement as shown in (c). 3. Re- entrant corner reinforcement shown herein is provided as a general guideline only and is subject to verification and changes by the project architect and /or structural engineer based upon slab geometry, location, and other engineering and construction factors. VINJE & MIDDLETON ENGINEERING, INC. PLATE 12 TRAPEZOIDAL CHANNEL ANALYSIS NORMAL DEPTH COMPUTATION December 23, 1999 2:i.:e)y.1 .No ;1flylER2 Y" DESCRIPTION Flow Rate ( cfs) .............. ............................... Channel Bottom Slope ( ft/ ft) . ............................... Manning's Roughness Coefficient (n- value) ................... Channel Left Side Slope ( horizontal /vertical) ............... Channel Right Side Slope ( horizontal /vertical) .............. Channel Bottom Width ( ft) .... ............................... COMPUTATION RESULTS DESCRIPTION Normal Depth ( ft )......• ...................... Flow Velocity (fps)•••••••••••••• " " " '• " " Froude Number ................... ••••••••••••• Velocity Head (ft)•••••••••••••••••••••••••'• Energy Head (ft) ............................. Cross - Sectional Area of Flow (sq ft) •••••••••• Top Width of Flow (ft) ••••••••••••••••••••-••• fi!771e� i;UF 0.015 1.54 1.54 0.25 Q N ' A_ p ­V 4 ------------ VALUE �F:....... `PC) 2� 1.21 �� upG0 ZXpTN p ' 7.38 " T40: 29577 m Exp. 3/31 /03 Lu 0.855 2.05 • . * 2.54 3.97 N il- �� �Tc — _— _-- --- — __ ---------- HYDROCALC Hydraulics for Windows, Version 1.2a Copyrig 1996 Dodson t Associates, Inc., 5629 FM 1960 West, Suite 314, Houston, TX 77069 Phone:(281)440 -3787, Fax:( 281) 440 - 4742, Email:software @dodson- hydro.com All Rights Reserved. 0lrc7z.xG exi ,>riIu° 0A1yfA)Uez D-72/W /. 93 lcee7_ S14M,6- //:::77- F zBo�l 7L `C OzvS / A1 7�iis C &r1XJ Av 6 Z - , &)E comma/ 6-*uL r4-DD /Av 6 1 Coue -1� OF lv ` 8reele 7-3 7Wt� eS 106:�_ 6� T//F c.s5Iry �t/cZ �S cf �iC/.0 aN c(�c rzw x/3-86 720 �C✓UTI� /N Caivdcy PEI, ✓J,4 ,z: P1 � � i E7 II -67 Zg EGG PiP� Al/CE ivcET Cvurrrl�c 160 10,000 166 - 8,000 EXAMPLE 156 0.42 1.16.. 13.3 I..I) 6. 6.000 6. 144 5,000 0.120 etc 5. - 4,000 I+ mw 6• 5. 132 0 1..1 3,000 5• 4• Ito (1) 243 e.e a, 2,000 12) z.l 7.. 108 (3) 2.2 7.7 4. 3. /p /, •D I. In1 3• , O`er o 96 1,000 3' 800 84 -- -- _ 600 - N 72 400 2 1.11,(:2 Nw. �� 3 300 ti %/ O� z.-2. 3B Z- 60 200 �/ h4\ D 1.3 18 B� / Zo o - 54 / rc '06'r '06'r � s a.N A?rDdl 3 o / P ° a 1.2 I•Zx Z> 2 •4Fr( w 46 /v 100 ((��LQi = 1.1 ZQ• "0r<[�,u�v_4{, v X42 � so `y w ).o La.. (� was al 0 — 50 ENT•R'ANCE ° - q� ° —40 C AL .� YPE ¢ 1.0 . i V W .. 1- .9 .9 L w (O �.• 4..r..a9. .un a 00L af, f 3 6 27. a ° 17•GS } k., tree.. .6 .�I%' ID w ... O.8'L 6 0,82_x *m. 2.%Frm • 1]I�\ Gnm ... - 27 / f$ 9r.1.c116E 0.70 X - O.ipor f �• IL�NOCE tZI "PV(, 4 8.5t IFS N°°� 7 o.(7,c1 = a.Hfr hW y 6A, PO G� T O 4444 1L•P✓c OKP,G"gE r7/ 6 T. n. .cm. 121 0 1 enl.ci 21 6ecice.1.111 1 ca. (1) h 4 41..1'.1 .cIl..4 ..nr..en Q(�OF SS /0, •• •' D%. uob. n.vu a. 6 �O E A. p'HC ' 1B 3 6 PyN RSO Fy )a P I s � ¢ N6. 29577 a 5 Exp.3/31/03 sT CIVIC Iz6PV( 12 HEADWATER DEPTH FOROFCAUFOP ^2,A<r CONCRETE PIPE CULVERTS WITH INLET CONTROL BUREAU Of PUBLIC ROADS JAN. 1963 ld=7— ,OEO 'D (-1k) Z-F -Tip/ = S. C54 F F 3.6,-,f 4.4 Tf,e�FOle� 24 �S lvneeec�AX-°zT 'o41AC rrxrrr + #f +f wf wff ♦wffflwwwwf wff R +xrxrrrrrrrrrrrrrr rrrrwf rt11t1111rr }rwr ++wwf} HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -92 Advanced Engineering Software (aes) Ver. 3.1A Release Date: 2/17/92 License ID 1386 Analysis prepared by: PASCO ENGINEERING, INC. 535 N. HIGHWAY 101, SUITE A SOLANA BEACH, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 ---------- ----------------- ---- -- TIME /DATE OF STUDY: 13:32 6/ 4/1999 wwwwwxwRxxxxRwRxxRRxrxRRxR DESCRIPTION OF STUDY # }1tt # ## #f lffffRRxxRR *Rf 1f • CHECK CAPACITY OF 24" RCP AT 10.75% • NODE 10 • ADDENDUM TO HYDRO. REPORT FOR ZAHOOR ABBASI 6 -4 -99 MS + RxRfRRxkxxRRRRR# RRRxRRRRRRRfRYRRxfflfiff llfffiffif #ff # #i #ifif lflfRRRxf #x#f ff} 1f111111fffrlf *f}lfiff*f #f}f + }f } } }f } * * * *R111 k* *111111ff *f }1* * * # * * **1f ** ** » » PIPEFLOW HYDRAULIC INPUT INFORMATION<<<< PIPE DIAMETER(FEET) = 2.000 FLOWDEPTH(FEET) = 1.900 PIPE SLOPE(FEET /FEET) _ .1075 MANNINGS FRICTION FACTOR - .013000 sssssss- ----- s=====ss svevasas sssassssasassssssssssasssssssss ssssssssssassss NORMAL -DEPTH FLOW INFORMATION: ---------- NORMAL DEPTH(FEET) = 1.90 FLOW AREA(SQUARE FEET) = 3.08 FLOW TOP- WIDTH(FEET) _ .872 FLOW PRESSURE + MOMENTUM(POUNDS) = 4169.75 -4 FLOW VELOCITY(FEET /SEC.) = 25.852 FLOW VELOCITY HEAD(FEET) = 10.378 HYDRAULIC DEPTH(FEET) - 3.54 FROUDE NUMBER = 2.423 SPECIFIC ENERGY(FEET) = 12.28 8INCR 79.7 CFS > 3 oF,4 fw►ff►f xwwwwfwwf :ixwf :wf: wxffxwfwwi if rtlrfrrirrf rfffffrtrt ♦ + #r +f# ++fffirffff HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -92 Advanced Engineering Software (aes) Ver. 3.1A Release Date: 2/17/92 License ID 1388 Analysis prepared by: PASCO ENGINEERING, INC. 535 N. HIGHWAY 101, SUITE A SOLANA BEACH, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 TIME /DATE OF STUDY: 11: 5 6/ 7/1999 ffff!•wi :wrxxfxxef iwxfwe ** DESCRIPTION OF STUDY ♦fi :fw * * * *iiiff + #rtrtfffffr: • CALCULATE DEPTH OF FLOW AND FLOW VELOCITY FOR 24" RCP t • TRES VISTAS ESTATES • Q100 + #t # #ritlftrf rfflf+ ti# tfi fiif #iiitartRff #k # * * * * * * ** * *iif if #ffx4frt #!rlffitft ## # #r # # # #+1lf iff4 # #lfki * #f kf * *** *► #if #wiiwtt iii #t #iilf!!f!lrirtltif k#f tf rffr >>>>PIPEFLOW HYDRAULIC INPUT INFORMATION<<<< ----------------------------------- PIPE DIAMETER(FEET) = 2.000 PIPE SLOPE(FEET /FEET) _ .0986 PIPEFLOW(CFS) = 27.54 MANNINGS FRICTION FACTOR = .013000 CRITICAL -DEPTH FLOW INFORMATION CRITICAL DEPTH(FEET) = 1.82 CRITICAL FLOW AREA(SQUARE FEET) = 3.001 CRITICAL FLOW TOP- WIDTH(FEET) = 1.147 CRITICAL FLOW PRESSURE + MOMENTUM(POUNDS) = 651.46 CRITICAL FLOW VELOCITY(FEET /SEC.) = 9.178 CRITICAL FLOW VELOCITY HEAD(FEET) = 1.31 CRITICAL FLOW HYDRAULIC DEPTH(FEET) = 2.62 CRITICAL FLOW SPECIFIC ENERGY(FEET) = 3.13 NORMAL -DEPTH FLOW INFORMATION: ---------------------------------------------------------------------------- JCNORMAL DEPTH(FEET) _ .864 FLOW AREA(SQUARE FEET) = 1.30 FLOW TOP- WIDTH(FEET) = 1.982 FLOW PRESSURE + MOMENTUM(POUNDS) = 1159.68 FLOW VELOCITY(FEET /SEC.) = 21.177 FLOW VELOCITY HEAD(FEET) = 6.964 HYDRAULIC DEPTH(FEET) _ .66 FROUDE NUMBER = 4.607 SPECIFIC ENERGY(FEET) = 7.83 I 30 or 3l'l b' min PLAN Concrete Channel fnt;t "A (IVp) Rock 70 or ification Claifi Cion x u 00,W 2 Backing TIGI ) -B /4 Ton 1.0 /2 Ton P. -10 �1 1.4 3/g• 19 -12 Lirht 2.0 _ 112' 12.14 1/: ion 2.7 3 /4' - 14 -16 - 7.4 L > 1 t` v O Thickness . 1 Foot or T. 'hichever is less c _ c 115E 0 STp� r S F c:�✓ 1 3 o <� I 30 or 3l'l b' min PLAN Concrete Channel fnt;t "A (IVp) 16 • IB 2 Ton 1 - tlith Sill Type 2 - t)ithoo[ sill l l l:i cl.ncsx of Pinr:e; Pile 0 ?:mctcr t` Patton GidtL of Concrete Chnlne: :fried on Plans Lccfic, Of RIP 'P A -10 F k ipso P -I O[i ;y Rock Th1 kness c ification Claifi Cion x u (T) Ft. 2 Backing TIGI ) -B /4 Ton 1.0 /2 Ton P. -10 1 To 16 • IB 2 Ton 1 - tlith Sill Type 2 - t)ithoo[ sill l l l:i cl.ncsx of Pinr:e; Pile 0 ?:mctcr t` Patton GidtL of Concrete Chnlne: :fried on Plans Lccfic, Of RIP 'P A -10 F k ipso P -I O[i ;y Rock Th1 kness c 1'i Cr clans•[ U;ner Laver Ft /Sec. Claifi Cion x u (T) Ft. Sec. 20�= �e`c. 497^ ) -B ) Back'-3 :10. 2 CaCkin3 1.0 P. -10 Fzcin7 1.4 3/g• 19 -12 Lirht 2.0 _ 112' 12.14 1/: ion 2.7 3 /4' - 14 -16 112 Ton 7.4 11 - 1 "- �.70 - Filter Clintet Thickness . 1 Foot or T. 'hichever is less 115E STp� r S F c:�✓ 1 _ Sill 420•C -2000 Class concrete. if sho•.m on Plans. ELEVATION 2- Dr" 2 ! \•IK10 1r Iwl ] \\ L.1 nil [rww -w[ 1 r1lpi ou nER D -40 S+nd !md Z Secf;on A.A ROTES: 1. Type of ripraP a. Regular Quarry Stone. • b. Broken Concrete if shown, on Plans. e. Cobbles not acceptable. 2. Gradation and Placenent as Specified in Regional Stendards Co". Std. Spec. Prov. Sec. 200 -1.6 and Sec. 3o0 -C. Y'3. Riprap is to be placed over a filter blanket which nay be granular material or plastic filter cloth. a. Granular naterial Specs. in Table above. I b. Plastic filter cloth specs.-in Reg. Ste,. Co.—.. Std. Spec. Prov. Sec. 200 -1.7- . 4. If desired riprap and filter blanket class is not available, use larger class. "4.* Standard Specifications for PubTic l,'orts Construction by So. CA Chap, of APIA i s ArC SAN DIEGO AFGIONAL STANDARD D12A7'/ING fires on Cy nppro:ad Dal, RIP RAP EI ?ERGY DISSIPATOR I HW --L- HW _r WATER .... PROJECTING ENO - UNSUBMERGEO PROJECTING END - SUBMERGED Is] MITERED END- SUBMERGED INLET CONTROL Figure I 5 -2 11-67 z q- <FGL PiPFS if/LE iuc�T �,u77�L ISO -10,000 168 8,000 EXAMPLE (I) (2) (3) 156 D•421.ch.. U.5 Ha) 6. 6,000 6. 144 5.000 O.IZa cl. 5. -4,000 ys mw 6. 5. 132 D f..t 3,000 It) 2.5 e.e 5' 4. q, Iz0 (2) 2.1 7.4 108 2,000 (3) 2.2 7.7 4. 3. 'D 1. 1.0 __ _ 3. A 0(� 96 1,000 3 7 L LY Boo 84 600 boo �� r - 2 ss B6Pi rfw N 72 400 2' = 7 300 1.5 1. I 5 . - 7, z N / \ IS`BK� Ue(aEZp Z- 60 zoo k w I S 0 ' r /•3 Fl/1*v s 34 ?• 3 ./• his •�P✓r ac�,c�sDa 3 FT- lfw U.1 45 100 n Lp/ Z 1.1 - ...' o K 0 0 u i42 60 y o_ I.0 N7cc 3! w 0 pp 0 50 O A L ENT ,YPEGE 1.0 LAI F 9 9 �% L w 10 „ f' guar .eg..Itn Q cot �P E 3 27.6 � n.ee.ml a .9 / li "� } - � cr n.ve..11 .nA' 10 = ... 0. �- B 0.'2 S 2b 0 / )L-)52E / 131 �• creou. Ana - 0.7D 0.7 27 r�2'�6 �� vreLel inv D K I o.7A FT. 60 .l,l -', rZ NIyLaK� MRS s:.l %. •' 7 4 „PV 4 /'• 8.S% IFS a .'� '7 -- •O.HKI = D.61fr hl*) t j/ G�4 7 0 �z`AC o�cPALt0. =sa/ 6ARCP 6 Te m. ¢a1. 121 e I Dr ei.et, 21 4 nerl.ent.ur 1 c.l. 111 * s oQPOFESSJp�4 uu rtrel nelin.e . through 3 �Ilu.liel.e, 6 yAe A. P,qs etc fuP ; ac w No. 29577 n' 5 Exp. 3/31/03 I.o 5 ST CIVR IVAK 2 HEADWATER DEPTH FOR! 9TFOFCpl -, ^E-A<? CONCRETE PIPE CULVERTS WITH INLET CONTROL BUREAU OF PUBLIC ROADS JAN 1963 - SINCE ,4V�4 /L . Ilk) Z5P7'1 O fT DEF7Tt-1 z4 1,5 D,� . �17'Ar f wewww wwwwwwwwwww wawewwrwwraaaaaa+ wwwwwrrwwwwaawrarwaaaaaw of awa wwrrrera♦wrraa HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -92 Advanced Engineering Software (aes) Ver. 3.1A Release Date: 2/17/92 License ID 1388 Analysis prepared by: PASCO ENGINEERING, INC. 535 N. HIGHWAY 101, SUITE A SOLANA BEACH, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 TIME /DATE OF STUDY: 13:32 6/ 4/1999 w. wr wRf #wRrww *RwR: wr rweRfx DESCRIPTION OF STUDY *•R•RR *RRf Rfflf lfffff /lf 1R • CHECK CAPACITY OF 24" RCP AT 10.758 • NODE 10 • ADDENDUM TO HYDRO. REPORT FOR ZAHOOR ABBASI 6 -4 -99 MS rrft#wf #f tffffffwfff #tlfflffwfRRRkRRRRRfffllf lR!!!!!!!!!ff#f#RwRRRkRRRf lfw >>>>PIPEFLOW HYDRAULIC INPUT INFORMATION« << ---------------------------------------------------------------------------- PIPE DIAMETER(FEET) = 2.000 FLOWDEPTH(FEET) = 1.900 PIPE SLOPE(FEET /FEET) . .1075 MANNINGS FRICTION FACTOR - .013000 ..................................... a._==._. ...._ ....... =..---............. NORMAL -DEPTH FLOW INFORMATION: NORMAL DEPTH(FEET) = 1.90 FLOW AREA(SQUARE FEET) = 3.06 FLOW TOP- WIDTH(FEET) = .872 FLOW PRESSURE + MOMENTUM(POUNDS) _ FLOW VELOCITY(FEET /SEC.) = 25.852 FLOW VELOCITY HEAD(FEET) = 10.378 HYDRAULIC DEPTH(FEET) = 3.54 FROUDE NUMBER = 2.423 SPECIFIC ENERGY(FEET) = 12.28 N .29577 Exp. 3/31/03 C) 4169.75 Fl LA �i7 1< i7e3 Z?�:1'17:7_[ ►/>1I�1:7�1�I:ii FOR ZAHOOR ABBASI P.O. BOX 462885 ESCONDIDO, CA 92046 -2885 PREPARED BY: PASCO ENGINEERING, INC. 535 NO. HIGHWAY 101, STE. A SOLANA BEACH, CA 92075 (619)259 -8212 EXP. 3131 199 WAYWt PASCO, RCE 2 577 V7 OQKUY�J�r(1i�•�� . c-lil�Q�P�E No.29577 Exp. 3/31/99 Cfvl1. 1P JP� 29 f TABLE OF CONTENTS IINTRODUCTION ......................................................... ..............................I IIDISCUSSION ................................................................ ..............................I IIICONCLUSION .............................................................. ..............................I IV HYDROLOGY CALCULATIONS ............................ ...........................2 -22 V HYDRAULIC CALCULATIONS ....................... ............................... 23- 27 VIAPPENDIX ........................................................... ............................... 'C8- 59 VIIEXHIBIT "A ......................................................... ............................... 1. INTRODUCTION The purpose of this report is to address the impact that storm runoff has on the proposed development of Lot 6 of Map 13320. Lot 6 is geographically located at North 33 003'45" latitude and West 117 °13'15" longitude. It is physically located on the southside of Double LL Ranch Road, approximately 800 feet west of Lone Jack Road. Based on the information contained in this report, recommendations will be made as to the size and type of drainage structure to be used and shown on the grading plan for TM 97 -219. II. DISCUSSION The development of Lot 6 consists of 5 graded pads with a private access road off of Double LL Ranch Road and private driveways to access each pad. The nature of the development requires fairly remote pads with long driveways that traverse the drainage areas and swales. Therefore, the drainage structures proposed on the grading plan consist of D -75 brow ditches, headwalls, short culverts, and rip -rap. All of the culverts are inlet controlled. The Hydrologic Soils Group for the entire project is "D" and the rural area runoff coefficient is 0.45. Refer to the hydrology calculations and exhibit "A" for runoff calculations and the drainage area map showing the node locations. Refer to hydraulic calculations for the headwater pipe sizing sheet. Each culvert is identified by node and corresponds to exhibit "A ". Refer to the appendix for supporting documents. III. CONCLUSION Based on the data and calculations contained in this report, it is the professional opinion of Pasco Engineering that the storm drain structures as proposed on the corresponding grading plan will adequately intercept, contain and convey Qioo to an appropriate discharge point. r IV HYDROLOGY CALCULATIONS ?Alp t fwrffwffrfrrrrr rref rwefffrf rf rf rffrrrr +if ere :frrefffr *f efrrrrrrrrrerrrrrrrf♦ RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT 1985,1981 HYDROLOGY MANUAL (c) Copyright 1982 -92 Advanced Engineering Software (aes) Ver. 1.3A Release Date: 3/06/92 License ID 1388 Analysis prepared by: Pasco Engineering, Inc. 535 Norht Hwy. 101, Suite A Solana Beach, CA 92075 Ph. (619) 259 -8212 Fax (619) 259 -4812 ---------------------------------------------------------------------------- FILE NAME: 710.DAT TIME /DATE OF STUDY: 9:45 2/17/1998 ---------------------------------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------------------------------- 1985 SAN DIEGO MANUAL CRITERIA USER SPECIFIED STORM EVENT(YEAR) - 100.00 6 -HOUR DURATION PRECIPITATION (INCHES) - 2.900 SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE _ .95 SAN DIEGO HYDROLOGY MANUAL "C "- VALUES USED NOTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED + +f rfw*#1 i+ f## rrrfrrfwwt• wwwwwwwwwwwwww+ kf+ wf #w + +rwwitrfw + # # + #1 + ++ + * *w #fwr #r FLOW PROCESS FROM NODE 126.00 TO NODE 124.00 IS CODE = 21 >>>>> RATIONAL METHOD INITIAL SUBAREA ANALYSIS««< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW - LENGTH = 240.00 UPSTREAM ELEVATION - 334.00 DOWNSTREAM ELEVATION - 319.00 ELEVATION DIFFERENCE = 15.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 9.841 *CAUTION: SUBAREA SLOPE EXCEEDS COUNTY NOMOGRAPH DEFINITION. EXTRAPOLATION OF NOMOGRAPH USED. 100 YEAR RAINFALL INTENSITY(INCH /HOUR) - 4.937 SUBAREA RUNOFF(CFS) _ .69 TOTAL AREA(ACRES) = .31 TOTAL RUNOFF(CFS) _ .69 FLOW PROCESS FROM NODE 126.00 TO NODE 124.00 IS CODE = 1 ---- ---- -------- --------- - - -- -- — ------------------------------------------- »»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE « «< TOTAL NUMBER OF STREAMS = 2 z CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 9.84 RAINFALL INTENSITY(INCH /HR) = 4.94 TOTAL STREAM AREA(ACRES) _ .31 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .69 »fffffff »fff exf xr *xxrrffffe » »+ :ri: rf ffe »rtf xrxxfff »ffrxrrrrr *fxxr # * * *rxreff ** FLOW PROCESS FROM NODE 125.00 TO NODE 124.00 IS CODE = 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 150.00 UPSTREAM ELEVATION = 318.80 DOWNSTREAM ELEVATION = 317.30 ELEVATION DIFFERENCE = 1.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 14.330 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.874 SUBAREA RUNOFF(CFS) _ .51 TOTAL AREA(ACRES) _ .29 TOTAL RUNOFF(CFS) _ .51 #ik ## # ## # #if# # * *r * * » * * * # # ## iii ## #1f #f * *ff *fffffff #frtif rt #f4fft *i # #iikxRffff ## FLOW PROCESS FROM NODE 125.00 TO NODE 124.00 IS CODE 1 -- - -------------- - ---------- - ---------- -- --- - -- - --------------- -- - ----- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES <<<<< -------------------------------------------------------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 14.33 RAINFALL INTENSITY(INCH /HR) = 3.87 TOTAL STREAM AREA(ACRES) _ .29 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .51 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 .69 9.84 4.937 .31 2 .51 14.33 3.874 .29 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 1.09 9.84 4.937 2 1.05 14.33 3.874 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 1.09 Tc(MIN.) = 9.84 TOTAL AREA(ACRES) _ .60 z liilffftfa4a4 #!a #af t4# 4# tlt fl iiffl RiiRkwRi #RiR! # #4R4 #444444Riifi #f afffff +i tf FLOW PROCESS FROM NODE 124.00 TO NODE 122.00 IS CODE = 4 >>>>> COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING USER - SPECIFIED PIPESIZE<<<<< _____________________________________________ DEPTH OF FLOW IN 24.0 INCH PIPE IS 2.0 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 8.9 UPSTREAM NODE ELEVATION - 316.30 DOWNSTREAM NODE ELEVATION - 307.80 FLOWLENGTH(FEET) = 50.00 MANNING'S N .015 GIVEN PIPE DIAMETER(INCH) 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.09 TRAVEL TIME(MIN.) _ .09 TC(MIN.) 9.93 +++l rrl: wwwwrriirl r++ rxxxxwxl wxwwwwwwwwl wwwwtwwwwwwfwrRwrRRwwfwwwwwwwwwwxxwx FLOW PROCESS FROM NODE 124.00 TO NODE 122.00 IS CODE = 1 >>r»DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 9.93 RAINFALL INTENSITY(INCH /HR) = 4.91 TOTAL STREAM AREA(ACRES) _ .60 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.09 w■ wRR+ axtrrwrRwxwwxxwwwxwwRRwRw++ wt+ ww+ rwwrwwwwwRf +xr +xw +ww + + +w +R # +ifrrirwri FLOW PROCESS FROM NODE 123.00 TO NODE 122.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 100.00 UPSTREAM ELEVATION = 309.80 DOWNSTREAM ELEVATION = 308.80 ELEVATION DIFFERENCE = 1.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) - 11.700 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.416 SUBAREA RUNOFF(CFS) _ .30 TOTAL AREA(ACRES) _ .15 TOTAL RUNOFF(CFS) _ .30 weirlf wrifrwxwwriil R+ w+ trwfrrrrrrxxxwwwwwrr lil4r #x4trrrrrr R•r Rrrtrr #Rr #rrrfr FLOW PROCESS FROM NODE 123.00 TO NODE 122.00 IS CODE = 1 -------------- ------------------- ------------ ------------------------------ >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< -------------------------------------------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 11.70 RAINFALL INTENSITY(INCH /HR) = 4.42 TOTAL STREAM AREA(ACRES) - .15 z PEAK FLOW RATE(CFS) AT CONFLUENCE _ .30 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.09 9.93 4.907 .60 2 .30 11.70 4.416 .15 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 1.35 9.93 4.907 2 1.27 11.70 4.416 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 1.35 Tc(MIN.) = 9.93 TOTAL AREA(ACRES) _ .75 xwwRwkRxwwxx# r# trffrtrr#* atiwwkxxxRxl rrrx♦ wr# # #www #!!r # #rrtx # #wwx #k! # #ffrx *w FLOW PROCESS FROM NODE 122.00 TO NODE 120.00 IS CODE . 53 >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW<<<<< >>>>>TRAVELT;ME THRU SUBAREA <<<<< UPSTREAM NODE ELEVATION 307.80 DOWNSTREAM NODE ELEVATION = 272.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 120.00 CHANNEL SLOPE _ .2983 CHANNEL FLOW THRU SUBAREA(CFS) = 1.35 FLOW VELOCITY(FEET /SEC) - 3.38 (PER PLATE D -6.3) TRAVEL TIME(MIN.) _ .59 TC(MIN.) = 10.53 •rxrr wrrxrrrwr :rrx * *affirwwwxxtxrlrlrwrr wrx x# as :wiwwwxr :ltrtrx #! #wwx!lrerrrx FLOW PROCESS FROM NODE 122.00 TO NODE 120.00 IS CODE . 1 ---------------------------------------------------------------------------- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« «< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 10.53 RAINFALL INTENSITY(INCH /HR) = 4.73 TOTAL STREAM AREA(ACRES) _ .75 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.35 fwwwrwrrifff ifrwrf wrffxwxxxatxf ixf i+ rrfr twrr# ! *lrrwwwx!lf xrlrlxwlrr!lrsx►!t! FLOW PROCESS FROM NODE 121.00 TO NODE 120.00 IS CODE = 21 ----------------------- ---- - ---------- ------- ---------- - ----------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< ------------------------------------------------------------ SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 e NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 11.56(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 420.00 UPSTREAM ELEVATION = 350.00 DOWNSTREAM ELEVATION = 272.00 ELEVATION DIFFERENCE = 78.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SUBAREA RUNOFF(CFS) = 6.23 TOTAL AREA(ACRES) = 3.11 TOTAL RUNOFF(CFS) = 6.23 FLOW PROCESS FROM NODE 121.00 TO NODE 120.00 IS CODE = 1 ------------ ---- - --------- - -- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< ----------------------------------------- ---------- --------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 11.56 RAINFALL INTENSITY(INCH /HR) = 4.45 TOTAL STREAM AREA(ACRES) = 3.11 PEAK FLOW RATE(CFS) AT CONFLUENCE = 6.23 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.35 10.53 4.727 .75 2 6.23 11.56 4.449 3.11 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CFS) 1 7.21 2 7.50 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) = Tc (MIN.) 10.53 11.56 ESTIMATES = 7. 3.86 INTENSITY (INCH /HOUR) 4.727 4.449 ARE AS FOLLOWS: 50 TcWIN.) = 11.56 rrrrrffrfrrrrr ixrrrxxr :x xrtt *fif *ff *fff; *ffrrrrrfrr srrftrtrr *rrrrrftxrr :xrrtf FLOW PROCESS FROM NODE 120.00 TO NODE 12.00 IS CODE = 8 ----- - ---- ------ - - -- - ----------- -------- - -- - -------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ____________ _________--------- ____________________ 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 4.38 SUBAREA RUNOFF(CFS) = 8.77 TOTAL AREA(ACRES) = 8.24 TOTAL RUNOFF(CFS) = 16.27 TC(MIN) = 11.56 f++++++ r +i # #} }} }wwxx# } # #t + +ri :r } #}w :rf+ ifs+ ft + + + #}wwwxxr #} } #r : + + +wxxi#♦r } +r# FLOW PROCESS FROM NODE 129.00 TO NODE 127.00 IS CODE = 8 --------- - -- ----------------------- -------- - ------------------------------ >> »)ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .27 SUBAREA RUNOFF(CFS) _ .54 TOTAL AREA(ACRES) 8.51 TOTAL RUNOFF(CFS) = 16.81 TC(MIN) - 11.56 #} i+# r} w}} wxwwxx#wrfiter #r +ffrf ♦ + #ww *wxwf Rfffrrrrff iftar # +wkxw # #if sr +r }r•ww+ FLOW PROCESS FROM NODE 128.00 TO NODE 127.00 IS CODE = 8 ---------------------------------------------------------------------------- »»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< --------------------- ------- --- -----_______________________ 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .21 SUBAREA RUNOFF(CFS) _ .42 TOTAL AREA(ACRES) = 8.72 TOTAL RUNOFF(CFS) = 17.23 TC(MIN) = 11.56 tfffff lf* ifff####} i## ffff f# t* it} i*# fffffffffffff ff *ff #i *}#} *ffttiff *ff#i#f }x FLOW PROCESS FROM NODE 118.00 TO NODE 119.00 IS CODE = 8 ---------------------------- >>>>> ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< --------------------------------------------- -- ----------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .21 SUBAREA RUNOFF(CFS) _ .42 TOTAL AREA(ACRES) = 8.93 TOTAL RUNOFF(CFS) = 17.65 TC(MIN) = 11.56 #}##f ii}} i}}f}} i#}}} i} wwwxwwx fwfffi #r +ff +fttfff#fRrif #wffeef rff rftffrf *f wf :x FLOW PROCESS FROM NODE 12.00 TO NODE 11.00 IS CODE = 3 ---------------------------------------------------------------------------- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW)<<<<< ---------------------------------------------- ------ -------- ---------------- DEPTH OF FLOW IN 21.0 INCH PIPE IS 13.5 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.8 UPSTREAM NODE ELEVATION = 230.00 DOWNSTREAM NODE ELEVATION = 222.00 FLOWLENGTH(FEET) = 100.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 21.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 17.65 TRAVEL TIME(MIN.) _ .15 TC(MIN.) = 11.72 rew wwrrrrrrrwr #ww } # #}r }wxwxwxwxwf x}##}##•# i+# +rir + + :} } }rw }rxii # }i }rttri}Rwwx FLOW PROCESS FROM NODE 12.00 TO NODE 11.00 IS CODE = 1 ------------ - - - - -- -- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 11.72 RAINFALL INTENSITY(INCH /HR) = 4.41 TOTAL STREAM AREA(ACRES) = 8.93 PEAK FLOW RATE(CFS) AT CONFLUENCE = 17.65 tt trttttxtxtxxxttrw + :rtxrt rat+++++ rt rt et xxxxt wtt + :rrtrrr +rrrrterxxtrrrr + +rr: FLOW PROCESS FROM NODE 111.00 TO NODE 11.00 IS CODE = 21 --------- ---- — -------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< ---------------------------------------- ------- ------- --------------- SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 150.00 UPSTREAM ELEVATION = 258.80 DOWNSTREAM ELEVATION = 257.30 ELEVATION DIFFERENCE = 1.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 14.330 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.874 SUBAREA RUNOFF(CFS) _ .66 TOTAL AREA(ACRES) _ .38 TOTAL RUNOFF(CFS) _ .66 t+ t:++ rrrr+att++ ar+ xraraaaa +atr +rrrxxtxxxxxxxxxxxxra +rrw +arts + +rrr +rrt tent FLOW PROCESS FROM NODE 111.00 TO NODE 11.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 14.33 RAINFALL INTENSITY(INCH /HR) = 3.87 TOTAL STREAM AREA(ACRES) _ .38 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .66 ** CONFLUENCE DATA ** Tc INTENSITY STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 17.65 11.72 4.411 8.93 2 .66 14.33 3.874 .38 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 18.23 11.72 4.411 2 16.17 14.33 3.874 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) 18.23 Tc(MIN.) = 11.72 TOTAL AREA(ACRES) . 9.31 #rr #r * ** *** * ** *#r+ * *f r x w w******* r## r** r*ww# ww * * ** *+r * #r # #r ##r #t+ *##r #sr* *r ww FLOW PROCESS FROM NODE 11.00 TO NODE 11.00 IS CODE . 8 - >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.411 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .59 SUBAREA RUNOFF(CFS) = 1.17 TOTAL AREA(ACRES) = 9.90 TOTAL RUNOFF(CFS) = 19.40 TC(MIN) = 11.72 frrfxrrrf a++++++++ xw* wwwxxrwrrwrrrx+ r* rffrr: r • :rr +ratwwxxxrxwrrwrfxfrrwwwrww FLOW PROCESS FROM NODE 11.00 TO NODE 10.00 IS CODE = 51 - -------------------------------------------------------------------------- » »>COMPUTE TRAPEZOIDAL CHANNEL FLOW « «< »»>TRAVBLTIME THRU SUBAREA« «< UPSTREAM NODE ELEVATION = 222.00 DOWNSTREAM NODE ELEVATION = 219.50 CHANNEL LENGTH THRU SUBAREA(FEET) 220.00 CHANNEL SLOPE _ .0114 CHANNEL BASE(FEET) = 1.00 "Z" FACTOR - 2.000 MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 1.00 CHANNEL FLOW THRU SUBAREA(CFS) . 19.40 FLOW VELOCITY(FEET /SEC) = 6.94 FLOW DEPTH(FEET) _ .96 TRAVEL TIME(MIN.) _ .53 TC(MIN.) - 12.25 # rwrrf* rs+ rs* rfx+ wrr*+ rr* f** iwtfri# t##*+###*# +*r**w *xx *wxwxxwxrr # *irR #awwxww FLOW PROCESS FROM NODE 11.00 TO NODE 10.00 IS CODE = 10 --------------------------------------------- ---- ---------------------- - -- - >>>>>MAIN- STREAM MEMORY COPIED ONTO MEMORY BANK # 1 <<<<< * r* r•: rr:* r*+ r++ rr*+* r** r**+* r*+* r+ r* rr###+ r+ + ++ +r * *r*wxwwxwwxww+ *rrrr +a *rr: FLOW PROCESS FROM NODE 126.00 TO NODE 314:00 IS CODE 21 --------------------------------------------1 A st CC) - -- -- --- ---- - -- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< ------------------------------------------------------------------------ SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 14.21(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 600.00 UPSTREAM ELEVATION = 331.30 DOWNSTREAM ELEVATION = 314.00 ELEVATION DIFFERENCE = 17.30 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.895 SUBAREA RUNOFF(CFS) = 3.58 TOTAL AREA(ACRES) = 2.04 TOTAL RUNOFF(CFS) = 3.58 z ► ►efrrwfrwf ifi # #wfi►►►f•rri►arww #►♦ff rw :f + + *w * #f► ►►►ffr ► ►arrw * ►fawt war rrrwxx FLOW PROCESS FROM NODE 343.00 TO NODE 342.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA« <<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW) <<<<< ------------------------------------------ ------------------------------- DEPTH OF FLOW IN 9.0 INCH PIPE IS 6.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.0 UPSTREAM NODE ELEVATION = 314.00 DOWNSTREAM NODE ELEVATION = 302.00 FLOWLENGTH(FEET) = 60.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 9.00 NUMBER OF PIPES . 1 PIPEFLOW THRU SUBAREA(CFS) = 3.58 TRAVEL TIME(MIN.) . .10 TC(MIN.) = 14.31 w #ww #wfiwffr + *f : ■ + :ff rrtww : + + +rr wwww►xf efffwrti + : ++rt *k #+k►f + +rrf wrr :w * *x +fr FLOW PROCESS FROM NODE 342.00 TO NODE 341.00 IS CODE - 53 ----- --- -- -- -- ------------ -------- -- - -------- -- --------- -- - - --- »» >COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< > »»TRAVELTIME THRU SUBAREA««< UPSTREAM NODE ELEVATION 302.00 DOWNSTREAM NODE ELEVATION = 264.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 150.00 CHANNEL SLOPE _ .2533 CHANNEL FLOW THRU SUBAREA(CFS) = 3.58 FLOW VELOCITY(FEET /SEC) = 4.31 (PER PLATE D -6.3) TRAVEL TIME(MIN.) . .58 TC(MIN.) = 14.89 * R#*##* R## fR*# f* fk# f* if+++ +awrf #ia # #ik # # * *f # * *f * *fr ► ♦ ►f ►f *•rr ►R * + *fwk►+ff Rfk FLOW PROCESS FROM NODE 342.00 TO NODE 341.00 IS CODE 8 » »>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW « «< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.779 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .80 SUBAREA RUNOFF(CFS) = 1.36 TOTAL AREA(ACRES) = 2.84 TOTAL RUNOFF(CFS) = 4.94 TC(MIN) = 14.89 rrrtrwrrtwftrrtwf• ftwt♦ wwww wt trt aewa •waxxxxxxxrwtrarf•♦farrt+ttwwf xffrfwtrw♦ FLOW PROCESS FROM NODE 341.00 TO NODE 34.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON- PRESSURE FLOW) <<<<< --------------------------------------------- --------------------- ---------- DEPTH OF FLOW IN 12.0 INCH PIPE IS 7.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.1 UPSTREAM NODE ELEVATION = 264.00 DOWNSTREAM NODE ELEVATION . 250.00 FLOWLENGTH(FEET) - 90.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) - 12.00 NUMBER OF PIPES 1 PIPEFLOW THRU SUBAREA(CFS) = 4.94 TRAVEL TIME(MIN.) _ .15 TC(MIN.) - 15.04 +: r++ ww+ ral rrwrxr}+f x++l rrxr + +r +rr +lr + + + +fff + }txwwwr }fx sf xxwwwrlftlxxx wr!!w+ FLOW PROCESS FROM NODE 34.00 TO NODE 31.00 IS CODE 53 >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW<<<<< >>>>>TRAVELTIME THRU SUBAREA<<<<< UPSTREAM NODE ELEVATION = 250.00 DOWNSTREAM NODE ELEVATION = 227.00 CHANNEL LENGTH THRU SUBAREA(FEET) - 160.00 CHANNEL SLOPE _ .1437 CHANNEL FLOW THRU SUBAREA(CFS) = 4.94 FLOW VELOCITY(FEET /SEC) = 3.61 (PER PLATE D -6.3) TRAVEL TIME(MIN.) = .74 TC(MIN.) = 15.78 +l rwr!!fl fff+*!* r+ www* ww* iffwl r!l xxxwrwwlw xfw #xwwwxfw :lxfwrxxwwwwrw +w +lwxxw! FLOW PROCESS FROM NODE 34.00 TO NODE 31.00 IS CODE = 10 ---------------------------------------------------------------------------- >>>>>MAIN- STREAM MEMORY COPIED ONTO MEMORY BANK # 2 <<<<< wf!}!!!! i} f!}4i }!4xllfirwwlwwfi}tfii +kifw xrlf!! }f if lflxf wwfi }ffflRf wwwrfffir FLOW PROCESS FROM NODE 125.00 TO NODE 322.00 IS CODE - 21 ---------------------------------------------------------------------------- »»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW - LENGTH = 200.00 UPSTREAM ELEVATION = 318.80 DOWNSTREAM ELEVATION = 316.80 ELEVATION DIFFERENCE = 2.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 16.546 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.531 SUBAREA RUNOFF(CFS) _ .56 TOTAL AREA(ACRES) = .35 TOTAL RUNOFF(CFS) _ .56 +++ rwwwwwwwwww:• wwrrf!!• fww + + #wwwwwwwrwwrrrwr +wrrlwxxrw wr ++++ +xrrrx + +rr + + +xr FLOW PROCESS FROM NODE 322.00 TO NODE 321.00 IS CODE 53 -------------- -- >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< »»>TRAVELTIME THRU SUBAREA<<<<< ------------------------------------------- ----------------"__'_______"'__ UPSTREAM NODE ELEVATION = 316.80 DOWNSTREAM NODE ELEVATION = 276.00 CHANNEL LENGTH THRU SUBAREA(FEET) - 150.00 CHANNEL SLOPE = .2720 CHANNEL FLOW THRU SUBAREA(CFS) _ .56 NOTE: CHANNEL FLOW OF 1. CFS WAS ASSUMED IN VELOCITY ESTIMATION FLOW VELOCITY(FEET /SEC) = 2.92 (PER PLATE D -6.3) i TRAVEL TIME(MIN.) _ .86 TC(NIN.) . 17.40 ************************** w****************** * * * * ** ** * * ** * **t ** ** ** *** * * ***e FLOW PROCESS FROM NODE 322.00 TO NODE 321.00 IS CODE = 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.418 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .44 SUBAREA RUNOFF(CFS) _ .68 TOTAL AREA(ACRES) _ .79 TOTAL RUNOFF(CFS) = 1.23 TC(MIN) = 17.40 **************************************** y**** * ** * * * ** * ** * * *** * *** * * **** * ** ** FLOW PROCESS FROM NODE 321.00 TO NODE 32.00 IS CODE = 3 »»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< » »>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW)<<<<< DEPTH OF FLOW IN 6.0 INCH PIPE IS 4.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 8.4 UPSTREAM NODE ELEVATION = 272.00 DOWNSTREAM NODE ELEVATION = 250.00 FLOWLENGTH(FEET) = 90.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 6.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.23 TRAVEL TIME(MIN.) _ .18 TC(MIN.) = 17.58 rr yrr** r** f******* y* r**************** y******* III ** *** * ** * ** ** * * *r**p *y4 *yryyyf FLOW PROCESS FROM NODE 321.00 TO NODE 32.00 IS CODE = 1 ---------------------------------------------------------------------------- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 17.58 RAINFALL INTENSITY(INCH /HR) = 3.40 TOTAL STREAM AREA(ACRES) _ .79 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.23 ********************************************* * ** * *w *** * ** * ** * *** *** *** ** **** FLOW PROCESS FROM NODE 332.00 TO NODE 331.00 IS CODE . 21 ----------------------- ------------------------------- - -------------------- » »>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 10.70(MINUTES) INITIAL SUBAREA FLOW - LENGTH = 180.00 UPSTREAM ELEVATION . 319.00 DOWNSTREAM ELEVATION = 270.00 t ELEVATION DIFFERENCE = 49.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.677 SUBAREA RUNOFF(CFS) _ .78 TOTAL AREA(ACRES) _ .37 TOTAL RUNOFF(CFS) _ .78 tfffftki* ff* fi}*+ fifftrif* ff* i* tf* tfi*}} f*f f### tt #t * # + *i * * #fi * * * *i * * *ii * * *k *i #i FLOW PROCESS FROM NODE 331.00 TO NODE 33.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON - PRESSURE FLOW)<<<<< -------------------------------------------- DEPTH OF FLOW IN 6.0 INCH PIPE IS 3.1 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.6 UPSTREAM NODE ELEVATION = 270.00 DOWNSTREAM NODE ELEVATION = 250.00 FLOWLENGTH(FEET) = 80.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 6.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) _ .78 TRAVEL TIME(MIN.) _ .17 TC(MIN.) = 10.88 +** rrrwiwfix* ffa**+ f**• xrx**** r*+ t++ t++ xfi *x+ +w + + : +rrf + +fx *xxxxx *wf *r *r +f *f r *e FLOW PROCESS FROM NODE 331.00 TO NODE 33.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< --------------- --- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 10.88 RAINFALL INTENSITY(INCH /HR) = 4.63 TOTAL STREAM AREA(ACRES) _ .37 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .78 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.23 17.58 3.395 .79 2 .78 10.88 4.628 .37 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CFS) 1 1.68 2 1.80 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) _ Tc INTENSITY (MIN.) (INCH /HOUR) 10.88 4.62B 17.58 3.395 ESTIMATES ARE AS FOLLOWS: = 1.80 Tc(MIN.) = 17.58 1.16 ++*******t******** t***+**********+*******+*** ** * * *t * *+ * *xr* * +* ** * * *** *rt *r ** FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 53 t ---------------------------------------------------------------------------- >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< >>>>>TRAVELTIME THRU SUBAREA<<<<< ------------------- -- --- --- -- -- ----- - - - - -- ------------------------- UPSTREAM NODE ELEVATION 250.00 DOWNSTREAM NODE ELEVATION = 227.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 150.00 CHANNEL SLOPE _ .1533 CHANNEL FLOW THRU SUBAREA(CFS) = 1.80 FLOW VELOCITY(FEET /SEC) = 2.67 (PER PLATE D -6.3) TRAVEL TIME(MIN.) _ .94 TC(MIN.) = 18.52 re :wtttt!•lwxtfi rlrerriixwfix++ r+ rl wwxifi xfifi rx!!!f !!iiliii +tt + + + +lre+rlf lff!!!f FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 11 >>>>> CONFLUENCE MEMORY BANK # 2 WITH THE MAIN- STREAM MEMORY <<<<< ** MAIN STREAM CONFLUENCE DATA +* STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.80 18.52 3.284 1.16 ** MEMORY BANK # 2 CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 4.94 15.78 3.641 2.84 ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc NUMBER (CFS) (MIN.) 1 6.56 15.78 2 6.26 18.52 COMPUTED CONFLUENCE ESTIMATES PEAK FLOW RATE(CFS) = 6. TOTAL AREA(ACRES) = 4.00 INTENSITY (INCH /HOUR) 3.641 3.284 ARE AS FOLLOWS: 56 TC(MIN.) = 15.78 lfrrlrrfff11f1rRrrffif kif rrflfilfwrrrllffffffirf +i4 +f lifwkixrlfllf!!!! +!!!!! FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 12 >>>>>CLEAR MEMORY BANK # 2 « «< xfwtxkl rrfi trxf wwfix+ rrtt txfr +rxxwr +flr +rxttlxfr +fiwwfi xxxrrrrtrf kiiittilx*xtxtx FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.641 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 1.22 SUBAREA RUNOFF(CFS) = 2.00 TOTAL AREA(ACRES) = 5.22 TOTAL RUNOFF(CFS) = 8.56 TC(MIN) = 15.78 * t# r##* xx* x+ r# f##* xr+ rrrrrrrrf##f## f## x* x* x** rrrrrr #rf #f + #f # + # #r +x *t + + +t +rrr FLOW PROCESS FROM NODE 31.00 TO NODE 30.00 IS CODE = 3 ---------------------------------------------------------------------------- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< »» >USING COMPUTER - ESTIMATED PIPESIZE (NON- PRESSURE FLOW) ««< ----------------------------------------------- ----------------------------- DEPTH OF FLOW IN 18.0 INCH PIPE IS 11.0 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.6 UPSTREAM NODE ELEVATION = 227.00 DOWNSTREAM NODE ELEVATION = 225.00 FLOWLENGTH(FEET) = 40.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 8.56 TRAVEL TIME(MIN.) _ .09 TC(MIN.) = 15.87 FLOW PROCESS FROM NODE 31.00 TO NODE 30.00 IS CODE = 8 ---------------------------------------------------------------------------- »» >ADDITION OF SUBAREA TO MAINLINE PEAK FLOW« «< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.628 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .13 SUBAREA RUNOFF(CFS) _ .21 TOTAL AREA(ACRES) = 5.35 TOTAL RUNOFF(CFS) = 8.77 TC(MIN) = 15.87 FLOW PROCESS FROM NODE 31.00 TO NODE 10.00 IS CODE = 51 >>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW««< >>>>> TRAVELTIME THRU SUBAREA<<<<< UPSTREAM NODE ELEVATION = 225.00 DOWNSTREAM NODE ELEVATION = 219.50 CHANNEL LENGTH THRU SUBAREA(FEET) - 150.00 CHANNEL SLOPE _ .0367 CHANNEL BASE(FEET) = 1.00 "Z" FACTOR = 2.000 MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 2.00 CHANNEL FLOW THRU SUBAREA(CFS) = 8.77 FLOW VELOCITY(FEET /SEC) = 8.76 FLOW DEPTH(FEET) _ .50 TRAVEL TIME(MIN.) _ .29 TC(MIN.) = 16.15 fx*f+* x*+# x+ x**#****#* x** x* f# f** x***+##* r* xx* * * * * * * * *t # *xx *rr + + # # # # #xxxxx *tx FLOW PROCESS FROM NODE 31.00 TO NODE 10.00 IS CODE = 8 ---------------------------------------------------------------------------- » » >ADDITION OF SUBAREA TO MAINLINE PEAK FLOW « «< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.586 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .59 SUBAREA RUNOFF(CFS) _ .95 TOTAL AREA(ACRES) = 5.94 TOTAL RUNOFF(CFS) = 9.73 TC(MIN) - 16.15 frrr * *iYf tffffxxr *t # #i#tf ttf + +rffxwxxk * # +i #trtr##f rx #wkfktt +t #Y#+ # #lfkitf4 *f FLOW PROCESS FROM NODE 30.00 TO NODE 10.00 IS CODE - 11 >>>>> CONFLUENCE MEMORY BANK # 1 WITH THE MAIN- STREAM MEMORY<<<<< ** MAIN STREAM CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CPS) (MIN.) (INCH /HOUR) (ACRE) 1 9.73 16.15 3.586 5.94 ** MEMORY BANK # 1 CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CPS) (MIN.) (INCH /HOUR) (ACRE) 1 19.40 12.25 4.288 9.90 ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CPS) (MIN.) (INCH /HOUR) 1 27.54 12.25 4.288 2 25.96 16.15 3.586 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 27.54 TC(MIN.) 12.25 TOTAL AREA(ACRES) = 15.84 + + +ft rxf w*#+* w++ Yf x*** t+t f+ tt+*f rwx**+#+ trr+# #xxxxwtr# + + + +r *tr ##rx +#xxwxxx +x FLOW PROCESS FROM NODE 10.00 TO NODE 1.00 IS CODE 3 >>r»COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON- PRESSURE FLOW) <<<<< DEPTH OF FLOW IN 21.0 INCH PIPE IS 15.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 14.2 UPSTREAM NODE ELEVATION = 219.50 DOWNSTREAM NODE ELEVATION = 204.00 FLOWLENGTH(FEET) = 120.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) - 21.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 27.54 TRAVEL TIME(MIN.) _ .14 TC(MIN.) = 12.39 #****** xf#**********+***rt*******+#** r*+**** x * * *** * **f *+* ** * *x *x ** * * * ** * **i* FLOW PROCESS FROM NODE 30.00 TO NODE 10.00 IS CODE = 12 >>>>>CLEAR MEMORY BANK # 1 « «< *+ rr:+ xx*+: xr## xx* tr++* r # * *x *x *it + # #rrxr *xxx +# + + + + *t *if rxxrxx #r +t + + +r :tirrrr FLOW PROCESS FROM NODE 201.00 TO NODE 202.00 IS CODE = 21 » » >RATIONAL METHOD INITIAL SUBAREA ANALYSIS « «< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 12.19(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 450.00 UPSTREAM ELEVATION = 320.00 DOWNSTREAM ELEVATION = 280.00 ELEVATION DIFFERENCE = 40.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.300 SUBAREA RUNOFF(CFS) = 3.46 TOTAL AREA(ACRES) = 1.79 TOTAL RUNOFF(CFS) = 3.46 * *fsa *exw * *sr ++ ass+* rrww * * +r*r *xt *t +r*s*r *xf *x * * * *+ +foss + +s +rrrxxxxxx*sxxff FLOW PROCESS FROM NODE 202.00 TO NODE 20.00 IS CODE = 4 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING USER - SPECIFIED PIPESIZE<<<<< ----------------------------------------------------------- DEPTH OF FLOW IN 24.0 INCH PIPE IS 3.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) a 11.0 UPSTREAM NODE ELEVATION - 280.00 DOWNSTREAM NODE ELEVATION - 211.00 FLOWLENGTH(FEET) = 600.00 MANNING'S N = .015 GIVEN PIPE DIAMETER(INCH) 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) 3.46 TRAVEL TIME(MIN.) _ .91 TC(MIN.) = 13.10 **ss****s************+*************fs******** * ** ** ** * * * * * * * * * * ** * * * * * * ** ** ** FLOW PROCESS FROM NODE 202.00 TO NODE 20.00 IS CODE - 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.105 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 1.33 SUBAREA RUNOFF(CFS) = 2.46 TOTAL AREA(ACRES) = 3.12 TOTAL RUNOFF(CFS) = 5.92 TC(MIN) = 13.10 * ww*******************************+*+***xw*** * ** ** *****w **w******* ******* * ** FLOW PROCESS FROM NODE 202.00 TO NODE 20.00 IS CODE - 1 ----------- ------------- --- - - ---- »»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE « «< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 13.10 RAINFALL INTENSITY(INCH /HR) = 4.11 TOTAL STREAM AREA(ACRES) = 3.12 PEAK FLOW RATE(CFS) AT CONFLUENCE = 5.92 R w1wr : + #rrrrarrewwwwx11 w1•++++ arr# ra: rrlrrrrrraxxa xxxlxwwwwllwwxwwwxwwlwwwlwl FLOW PROCESS FROM NODE 231.00 TO NODE 23.00 IS CODE 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 120.00 UPSTREAM ELEVATION = 258.80 DOWNSTREAM ELEVATION = 257.60 ELEVATION DIFFERENCE = 1.20 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 12.817 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.163 SUBAREA RUNOFF(CFS) _ .56 TOTAL AREA(ACRES) _ .30 TOTAL RUNOFF(CFS) _ .56 fittt# ff### f# fi# *t # #f * * **R111kff # #1r#r # ##f# #* ## #1111111 ra4#*kf #f * # #t #t #itt ## FLOW PROCESS FROM NODE 23.00 TO NODE 22.00 IS CODE = 4 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING USER- SPECIFIED PIPESIZE ««< ------------------------------------- --------------- DEPTH OF FLOW IN 24.0 INCH PIPE IS 1.4 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.7 UPSTREAM NODE ELEVATION = 256.60 DOWNSTREAM NODE ELEVATION = 237.00 FLOWLENGTH(FEET) - 100.00 MANNING'S N .015 GIVEN PIPE DIAMETER(INCH) - 24.00 NUMBER OF PIPES 1 PIPEFLOW THRU SUBAREA(CFS) _ .56 TRAVEL TIME(MIN.) . .22 TC(MIN.) - 13.03 rxxwxw + +xr rrwraxwwlxx +ar rrrxraxx11x11+++ xt rrrrrrataaxx1w11wr + +xaa xrxaxrrrrr+ FLOW PROCESS FROM NODE 23.00 TO NODE 22.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.119 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .25 SUBAREA RUNOFF(CFS) _ .46 TOTAL AREA(ACRES) _ .55 TOTAL RUNOFF(CFS) = 1.03 TC(MIN) = 13.03 writ+ trrlxwr++ tw♦* wwwwl •lrwfrrxr•1rrlrwxr +frw +xrrtrarr xaxxw axfxawlxxawlwr #rw FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE 4 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>> USING USER - SPECIFIED PIPESIZE« <<< DEPTH OF FLOW IN 24.0 INCH PIPE IS 2.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.3 UPSTREAM NODE ELEVATION = 237.00 DOWNSTREAM NODE ELEVATION = 211.00 FLOWLENGTH(FEET) = 260.00 MANNING'S N = .015 GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.03 TRAVEL TIME(MIN.) _ .60 TC(MIN.) = 13.63 rttt** 4* f* ii# i• Yrt** *R *RR*iittff *ff * #irtYY *R * *R *Ri #f i# * *Ri #f kf * *R * * *rtrt * *Yrtrtrt *rtrt FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.001 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .68 SUBAREA RUNOFF(CFS) = 1.22 TOTAL AREA(ACRES) = 1.23 TOTAL RUNOFF(CFS) = 2.25 TC(MIN) = 13.63 # Y*## rt**********#i***** * * * * * * *f**f# ** *** ** * * ** * *f# ***f if# * *i* *#f*i* * ** ** * * ** FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 13.63 RAINFALL INTENSITY(INCH /HR) = 4.00 TOTAL STREAM AREA(ACRES) = 1.23 PEAK FLOW RATE(CFS) AT CONFLUENCE = 2.25 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 5.92 13.10 4.105 3.12 2 2.25 13.63 4.001 1.23 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CFS) 1 8.11 2 8.02 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) _ Tc (MIN.) 13.10 13.63 ESTIMATES 8. 4.35 INTENSITY (INCH /HOUR) 4.105 4.001 ARE AS FOLLOWS: 11 Tc(MIN.) = 13.11 #*********# t* f*** t* R** itttf* t*** t* 4R**fi** f** * * * * * * * ** * *4 *i ** * * * ** * * * ** *** ** FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE <<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 13.10 RAINFALL INTENSITY(INCH /HR) = 4.11 TOTAL STREAM AREA(ACRES) = 4.35 PEAK FLOW RATE(CFS) AT CONFLUENCE = 8.11 +** rrxwx**♦* r++** rrxwww * * + *r *r +r +i+ * * * * * *rrxwwwx*r ++ +tit * * * *rt * *a r +err rrrr rr FLOW PROCESS FROM NODE 211.00 TO NODE 21.00 IS CODE 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< ___--`--- - - - -- --------------- ----- SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 250.00 UPSTREAM ELEVATION = 219.80 DOWNSTREAM ELEVATION = 217.30 - ELEVATION DIFFERENCE = 2.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 18.499 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.286 SUBAREA RUNOFF(CFS) = 1.63 TOTAL AREA(ACRES) = 1.10 TOTAL RUNOFF(CFS) = 1.63 rrw************** *******x**r*** +*rrrr****x****** i****** x w******* r****+* ♦t*** FLOW PROCESS FROM NODE 211.00 TO NODE 21.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 18.50 RAINFALL INTENSITY(INCH /HR) = 3.29 TOTAL STREAM AREA(ACRES) = 1.10 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.63 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 8.11 13.10 4.105 4.35 2 1.63 18.50 3.286 1.10 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CFS) 1 9.42 2 8.12 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) _ TC (MIN. 13.10 18.50 ESTIMA' 5 INTENSITY (INCH /HOUR) 4.105 3.286 PES ARE AS FOLLOWS: 9.42 Tc(MIN.) = 13.1C .45 t** r**** III, * III ****** III ** r► r*** III * III * x**f x III * III # r**** III, ** III a*t *w * * *r*r* * * * * * * * *► * * * * ► ** FLOW PROCESS FROM NODE 21.00 TO NODE 20.00 IS CODE = 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.105 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .92 SUBAREA RUNOFF(CFS) = 1.70 TOTAL AREA(ACRES) = 6.37 TOTAL RUNOFF(CFS) = 11.12 TC(MIN) - 13.10 tR##* ra► taf##*+ ifffr* rka/lt if♦ k#t* ww**### itk# r * * *wxRxw #wkR * # # * * * * * * * * * # #ww ** FLOW PROCESS FROM NODE 20.00 TO NODE 2.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON- PRESSURE FLOW)<<<<< DEPTH OF FLOW IN 21.0 INCH PIPE IS 13.3 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 6.9 UPSTREAM NODE ELEVATION - 208.00 DOWNSTREAM NODE ELEVATION - 206.50 FLOWLENGTH(FEET) = 45.00 MANNING'S N .024 ESTIMATED PIPE DIAMETER(INCH) = 21.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) 11.12 TRAVEL TIME(MIN.) = .11 TC(MIN.) - 13.21 *k # #a#rrfaawR * # * #ai #iftrr re:* ffaRk* w**##* afr* ► ► * ►1t ►****f #t **w * * + #k4a + ##if #t FLOW PROCESS FROM NODE 3.30 TO NODE 3.10 IS CODE = 21 ---------------------------------------- ----- ---- -- -- ----- ---- -- -- - -- -- -- -- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 130.00 UPSTREAM ELEVATION = 316.80 DOWNSTREAM ELEVATION = 315.50 ELEVATION DIFFERENCE = 1.30 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 13.340 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.057 SUBAREA RUNOFF(CFS) _ .46 TOTAL AREA(ACRES) = .25 TOTAL RUNOFF(CFS) _ .46 x **** * *a * *a w w w********* * * * * ** * #w * *****t*** *** **a **** *x w**wx * * * * * ** * * *w * * #w ** FLOW PROCESS FROM NODE 3.10 TO NODE 3.00 IS CODE = 6 ------------------ --------------------------------------------------------- >>>>>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA <<<<< ------------------------------------------------------- ------------------- - UPSTREAM ELEVATION = 315.50 DOWNSTREAM ELEVATION = 212.00 STREET LENGTH(FEET) = 800.00 CURB HEIGHT(INCHES) = 6. STREET HALFWIDTH(FEET) = 18.00 DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 16.00 INTERIOR STREET CROSSFALL(DECIMAL) _ .020 OUTSIDE STREET CROSSFALL(DECIMAL) = .020 SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1 * *TRAVELTIME COMPUTED USING MEAN FLOW(CFS) _ .99 STREETFLOW MODEL RESULTS: STREET FLOWDEPTH(FEET) _ .17 HALFSTREET FLOODWIDTH(FEET) = 2.27 AVERAGE FLOW VELOCITY(FEET /SEC.) = 5.81 PRODUCT OF DEPTH &VELOCITY - 1.00 STREETFLOW TRAVELTIME(MIN) = 2.30 TC(MIN) - 15.64 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.662 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .64 SUBAREA RUNOFF(CFS) = 1.05 SUMMED AREA(ACRES) _ .89 TOTAL RUNOFF(CFS) = 1.51 END OF SUBAREA STREETFLOW HYDRAULICS: DEPTH(FEET) = .20 HALFSTREET FLOODWIDTH(FEET) = 3.82 FLOW VELOCITY(FEET /SEC.) = 5.72 DEPTH *VELOCITY = 1.16 rr+ rr+ rxxrrarr+ rr+ rrrrrr♦ trtxxrr+ rrr• xrxxxx+ rrrr +rr : : +r :rr + +r + + + +r +r + : +r+r +r FLOW PROCESS FROM NODE 3.20 TO NODE 3.00 IS CODE 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW« «< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.662 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .43 SUBAREA RUNOFF(CFS) _ .71 TOTAL AREA(ACRES) = 1.32 TOTAL RUNOFF(CFS) = 2.22 TC(MIN) = 15.64 --- --------- ------------ - END OF STUDY SUMMARY: PEAK FLOW RATE(CFS) = 2.22 TC(MIN.) = 15.64 TOTAL AREA(ACRES) = 1.32 END OF RATIONAL METHOD ANALYSIS Z3 V HYDRAULIC CALCULATIONS zg s�GL P1Pe:5 160 10,000 168 8,000 EXAMPLE (I) (2) (3) 6. 156 6,000 O•42 inches 13 -3 feel) 6. S•000 0.120 cr. 5. 44 6. 5. - 4,000 Z,w' Nw 132 o r.•1 4, 3,000 (1) 2.5 B.8 5" 4. 120 12t 21 7♦ 2,000 l3) 2.2 7.7 4• IOB 3 3. A , O� D In feet !X 96 1,000 3 000 84 600 /// I• 2 .66X! b9fpT Aid 500 tLPN 72 400 / = 300 1.5 1. - 5 X /, v . Z.'L$ FT bW 1. wope 7,0 Z-60 zoo / �k D. 1.5 �.sx / /•3PrsN.) z / E isr•PVr ivW�0 t.uDa a 0 54 / nP�o� a t.2 I•Z>(2� 2•AFrf �T w 4B /w loo / I.1 = iQ•"�K.� ED > i 80 = 1. 17 >< /r •i = l•76 HA1 J V 142/ 60\1' w 1.0 I.O.: ��P OIL DOE al LLo T 50 HW ENT•R•ANCE 0 I.0 - 40 p SCAL ;r YPE w w .9 30 p Eve 1- .9 UJ OR at i n.od.all p .9 33 27.6 N 6r.... •n Will. IO w ... D. P1L 0.82-X 8 0.8X I31 �• Groan end 0.78 0 7O K .r.l.clino I - a78 fT. rhtl 27 00,0, f CFi P ,1,1 IzP/VLO/ &^yc:i -sL1 / $.SL IFS �' .ff 'T ,7 o.ofK1 = 44 pr- Hw 1. PV( 241/. a� / 7 •. pE7� 8 fz'GYL OK P.IAOgE 3d/ P 6 T. ..• ac.q 121 e 1 .rej•cI., - 21 1'er is.nl.Ilr I cal• 11], T 4 .14 .1'.1 inclined is rnr.•pe o end .ca1u I ... Is. .• 6 .6 3 ❑Iwti el.d. 6 � IB Vac. •°' ba'' fuP 15 ;• a.p S 5 WA(C 12 HEADWATER DEPTH FOR nt,R•cr CONCRETE PIPE CULVERTS WITH INLET CONTROL BUREAU Of PUBLIC ROADS JAN 1963 11f1fff+ R# fwl 44l 4l tw!! t!!! !wt!!!!!4w #wR *fR #wR *w * #R! * #fR #f wf► ► ►►► ► ► ► ►iitf lff# HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -96 Advanced Engineering Software (aes) Ver. 6.1 Release Date: 01/01/96 License ID 1452 Analysis prepared by: Pasco Engineering, Inc. 535 North Hwy. 101, Suite A Solana Beach, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 TIME /DATE OF STUDY: 13:56 5/ 5/1998 ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- + + + ++ + ►f ► + + : + + + + *tiiir►►►• DESCRIPTION OF STUDY ►► ►w #x!!rf■ ►f►• ++ ►rf trwf +r * Check Maximum Depth of flow in trapezoidal channel * Node 11 to Node 10. Q100 at Node 10 used for this CALC. * 100 year storm. See exhibit A. 5 -5 -98 ms x►►f wffir ► +► ► ►►x +R #+f +fff *Rrw :f lwxf #rw #ff ►fww * + + + + + + + * * + + + + +w + : +ff w►r♦ :►++ + * #ff ► ► ► ►f RfR# w**** R * * * * # ►w *R ## * ►w# # *4f ## ►f# # + # #fff iftwf tll4 #► # *# # * * *wR # * # ## > >>> CHANNEL INPUT INFORMATION «« ---------------------------------------------------------------------------- CHANNEL Z1(HORIZONTAL /VERTICAL) = 2.00 Z2(HORIZONTAL /VERTICAL) = 2.00 BASEWIDTH(FEET) = 1.00 CONSTANT CHANNEL SLOPE(FEET /FEET) _ .012500 UNIFORM FLOW(CFS) = 27.50 MANNINGS FRICTION FACTOR .0150 ---------------------------------------------------------------------- NORMAL -DEPTH FLOW INFORMATION: ---------------------------------------------------------------------------- » »> NORMAL DEPTH(FEET) = 1.10 FLOW TOP- WIDTH(FEET) = 5.40 FLOW AREA(SQUARE FEET) = 3.52 HYDRAULIC DEPTH(FEET) _ .65 FLOW AVERAGE VELOCITY(FEET /SEC.) = 7.81 UNIFORM FROUDE NUMBER = 1.703 PRESSURE + MOMENTUM(POUNDS) = 509.24 AVERAGED VELOCITY HEAD(FEET) _ .946 SPECIFIC ENERGY(FEET) 2.047 -------------------------- ------ - - -- CRITICAL -DEPTH FLOW INFORMATION: ___ __ _____ _______ __ CRITICAL FLOW TOP- WIDTH(FEET) = 6.64 CRITICAL FLOW AREA(SQUARE FEET) 5.39 CRITICAL FLOW HYDRAULIC DEPTH(FEET) _ .81 CRITICAL FLOW AVERAGE VELOCITY(FEET /SEC.) = 5.10 CRITICAL DEPTH(FEET) = 1.41 CRITICAL FLOW PRESSURE + MOMENTUM(POUNDS) = 450.73 AVERAGED CRITICAL FLOW VELOCITY HEAD(FEET) _ .405 CRITICAL FLOW SPECIFIC ENERGY(FEET) = 1.815 Z5 HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -96 Advanced Engineering Software (see) Ver. 6.1 Release Date: 01/01/96 License ID 1452 Analysis prepared by: Pasco Engineering, Inc. 535 North Hwy. 101, Suite A Solana Beach, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 ---------------------------------------------------------------------------- TIME /DATE OF STUDY: 15: 7 5/ 5/1998 DESCRIPTION OF STUDY xfl,f!!! #xxxxfxxf xxexx *+ +* * CHECK DEPTH OF FLOW OF D -75 TYPE "B" DITCH AT WORST CASE. * $W CJ WA3,11' f,o 1 �tvD� 343. wR too +5m *** k}#+l fw►f R# fR**** A****#*####*# f###+##+ w+, R #R!#k #fk #R # #R # #! * #!!R # * *f!f #1f, >>>>PIPEFLOW HYDRAULIC INPUT INFORMATION «« ---------------------------------------------------------------------------- PIPE DIAMETER(FEBT) = 2.000 PIPE SLOPE(FEET /FEET) _ .0200 PIPEFLOW(CFS) = 3.60 MANNINGS FRICTION FACTOR = .015000 - ---- ---------------- ----------- --- CRITICAL -DEPTH FLOW INFORMATION: CRITICAL DEPTH(FEET) _ .66 CRITICAL FLOW AREA(SQUARE FEET) _ .912 CRITICAL FLOW TOP- WIDTH(FEET) = 1.884 CRITICAL FLOW PRESSURE + MOMENTUM(POUNDS) = 43.29 CRITICAL FLOW VELOCITY(FEET /SEC.) = 3.948 CRITICAL FLOW VELOCITY HEAD(FEET) _ .24 CRITICAL FLOW HYDRAULIC DEPTH(FEET) _ .48 CRITICAL FLOW SPECIFIC ENERGY(FEET) _ .91 -------------------------------------- NORMAL -DEPTH FLOW INFORMATION: NORMAL DEPTH(FEET) - .49 FLOW AREA(SQUARE FEET) _ .59 FLOW TOP- WIDTH(FEET) = 1.716 FLOW PRESSURE + MOMENTUM(POUNDS) = 49.96 FLOW VELOCITY(FEET /SEC.) = 6.089 FLOW VELOCITY HEAD(FEET) _ .576 HYDRAULIC DEPTH(FEET) _ .34 FROUDE NUMBER = 1.828 SPECIFIC ENERGY(FEET) = 1.06 DESCRIPTION OF STUDY * * #w *x * * * ** * * * *r *R * # * * # # #* :06 L 'repared by Pasco Engineering 5/5/98 PE 718 515/98 CALCULATE CAPACITY OF BROOKS CATCH BASINS. FORMULA: Qcap = 3.0(P)(D ^1.5) / 2. DIVISION BY 2 ACCOUNTS FOR GRATE. PERIMETER AVAIL HW GRATE FACTOR Q100 (CFS)" P (FT) D (FT)' 2.00 CAPACITY (CFS) INLET TYPE 0.78 4.00 0.50 3.00 1.41 12" x 12" BROOKS CB 1.23 4.00 0.50 3.00 1.41 12" x 12" BROOKS CB 0.5 FT. DEPTH ALLOWS FOR 0.5 FT. FREEBOARD IN D -75 DITCH. " - SEE EXHIBIT "A" NODE 321 AND 331 FOR THESE Q100 VALUES. 27 I VM. W-Dia0kl S COUNTY OF SAN DIEGO FLOOD OF SANITATION L 100-YEAR u - "t louvi PRE�4dd��'�'TID,� FLOOD CONTROL ` �,p i 6 Z -20.✓ ISOPLUVIALS OF 100 -YEAR 6 -HOUR 451 TIADA sC� \�� ,I �a,U 1 - \q v.c : A BEACH 35 ,) �\ ! 35 301 - 30 °\ .1i_ Sn I. J ��O\ lo. �ACCCA SAN \ (�.l. 1 !\ \�:. _ _ 151 ' - ego T ZOCA PA/ 4'4" 33° 451 ---..__ - P"P. rd Dr U.S. DEPARTMEN I' OF COMMERCE NATIONAL OCEANIC AND AT` OSPIIERIC AD " ""TRATION SPECIAL STUDIES BRANCH, OFFICE OF 1. UROLOGY. NATIONAL WEATIIER SERVICE 30' 1181 451 301 a Ei MAFIj 20 15' 117° 3 p 40 J (�� � (N 7 r 45 'r, I 5 `1, 3 �I Q - 3p 0 1151 301 15' 116' 1 COUNTY OF SAN DIEGO DEPARTMENT OF SANITATION b FLOOD CONTROL 451 301 151 33° SAN CL MEN1E 100 -YEAR 24- 1,10011 PRECIPITATION "- 20•JISOI'LUUIALS 6"T 100 -YEAR 24 -IIOUR PRECIPITATION IN THITHS OF All INCA 120j c22 /J G si o s � .. .7Q.. - :� •lQa � ST 1 `. ( c SAf 4VV1 _.:. \`I� 1) .. 451 V reps .Q e, , U.S. DEPARTNL•'N I. OF Co11hIERCE NATIONAL OCLANIC AND Al" O]PIIERIC AUUINIS'fRAT1ON SPECIAL STUDIES UFANCII, OFFICE OF UROLOGY. NATIONAL u'EATIIER SERVICE j01 H t191" II�1 301 w r1r, IA r t L. 1 v 5 1-.- -f•q s5:GOg0- 8a'ovU 1i1 117' )I,;I 30 �- J C I\ i J _IDD.. Ip--'65GD 301 1 -I< 35- C^.1�_ AIL I -- 1454H. r VII EXHIBIT "A" 3/ k, V COST ESTIMATE FOR: PARCEL MAP 18124, REMAINDER PARCEL GRADING PLAN ZACK ABBASI PE 718REM 19:i�L•l:ix�l:]'E PASCO ENGINEERING, INC. 535 NO. HIGHWAY 101, STE. A SOLANA BEACH, CA 92075 (619) 259 -8212 01/18/1999 k! ! '� !/" WAYNE PASCO, KCE 29577 DATE N 9 � Q�o A. ti� p Ey\. �P No.29577 Exp. 3/31/99 iz �ujAp CIVIV �Q PE 718rem 01/18/1999 GP DWG. NO. 5744 -G PRIVATE GRADING AND DRAINAGE BOND ESTIMATE CITY OF ENCINITAS ITEM QTY UNIT @ UNIT PRICE TOTAL GRADING• EXCAVATION /EMBANKMENT 900 CY @ $3.90 $3,510.00 SUB TOTAL $3,510.00 10% CONTINGENCIES $351.00 TOTAL $3,861.00 DRAINAGE: 12 "x12" AREA DRAIN 1 EA @ $200.00 $200.00 6" AC BERM G -5 105 LF @ $7.80 $819.00 AC PAVING (DRIVEWAY) 1680 SF @ $1.60 $2,688.00 D -27 UNDERDRAIN PIPE 1 EA @ $310.00 $310.00 6" PVC DRAIN PIPE 15 LF @ $15.00 $225.00 SUB TOTAL $4,242.00 10% CONTINGENCIES $424.20 TOTAL $4,666.20 EROSION CONTROL: GRAVEL BAGS 400 EA @ $1.00 $400.00 HYDROSEED SLOPE PROTECTION 4350 SF @ $0.11 $478.50 SUB TOTAL $878.50 10% CONTINGENCIES $87.85 TOTAL $966.35 GRAND TOTAL 59,493.55 2i1 (* I9q ,epared by Pasco Engineering 01/18/199.. PE 718 01/18/1999 CALCULATE CAPACITY OF AREA DRAIN ON REMAINDER PARCEL PAD. - ORMULA: Qcap = 3.0(P)(D ^1.5) / 2. DIVISION BY 2 ACCOUNTS FOR GRATE. PERIMETER AVAIL HW GRATE FACTOR Q100 (CFS)" P (FT) D (FT)' 2.00 CAPACITY (CFS) INLET TYPE 0.82"' 4.00 0.50 1.23 4.00 0.50 3.00 1.41 3.00 1.41 PE 242M 12" x 12" AREA DRAIN 12" x 12" BROOKS CB 0.5 FT. DEPTH ALLOWS FOR 0.5 FT. FREEBOARD. SEE EXHIBIT "A" NODE 211 TO 21 FOR THESE Q100 VALUES. 211 TO 21 =1.63 CFS SINCE 1/2 OF PAD IS INTERCEPTED BY 12"X12" AREA DRAIN. 0.82 CFS IS NOW USED FOR THIS CALCULATION. Q�pFESSiDHq 29577 Exp. 3/31/99 y Gs �NG\\� O\F NGN\tPS G }, y VINJE & MIDDLETOI Job 97 -145 -V December 21, 1998 ENGINEERING, INC. Development Planning Consultants International, Inc. Attention: Mr. Zach Abbas! t 131 South Escondido Boulevard Escondido, California 92025 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 f �o �2g1� Phone(760)743 -1214 Fax (760) 739-0343 Updated Preliminary Geotechnical Investigation Report and Grading Plan Review, Job #97- 145 -v, Dated May 27, 1997, Double LL Ranch Road, Olivenhain In accordance with your request, we have completed the following updated Geotechnical Report for the above referenced project site. Based upon our recent visual inspections, site conditions have primarily remained unchanged since issuance of our original report entitled "Preliminary Geotechnical Investigation, Proposed 5 Parcel subdivision, APN 264 - 240 -03, Double LL Ranch Road, Olivenhain, City of Encinitas, California," Job #97- 145 -V, dated May 27, 1997- All conclusions and recommendations provided in the referenced project soils report, and the subsequent "Clarification Letter on Preliminary Geotechnical Investigation Report, Job #97- 145 -V, Dated May 27, 1997, Double LL Ranch Road, Olivenhain," dated April 28, 1998, remain valid and should be incorporated into the final plans and implemented during the construction where appropriate and applicable. The need for an additional study and/or subsoils investigation is currently not indicated. The following additional pertinent report(s) and plan(s) related to the project site were also reviewed in connection with this updated study: 1. Grading Plan for Remainder Parcel, Tres Vistas Estates, TMP 97 -201, prepared by Pasco Engineering, not dated. 2. Grading Plan for TM 97 -219, prepared by Pasco Engineering, not dated. 3. Response to Consultant Review of "Preliminary Geotechnical Investigation, Proposed 5 Parcel subdivision, APN 264- 240 -03, Double LL Ranch Road, Olivenhain, City of Encinitas," prepared by Vinje & Middleton Engineering, Inc., Job #97- 145 -V, dated August 1, 1998. Based on our review, the following comments are appropriate: The tentative map included in the above referenced Preliminary Geotechnical Investigation Report, dated May 27, 1997, has been revised with respect to parcel numbers. 2. The previously addressed "Parcel 3" (page 11 of the subject report) is now "Parcel 2" in the revised map. The east end of the cut slope construction for this parcel may also expose weaker claystone units. In these areas where slope heights exceed 5 vertical feet A Development Planning Consultants International, Inc. Attention: Mr. Zach Abbasi December 21, 1998 Page 2 maximum, the cut bank may also be reconstructed as a stabilization fill slope at 2:1 gradients. The previously addressed "Parcel 2" (Page 10 of the subject report) is now the "Remainder Parcel' and previous "Parcel 4" (Page 11 of the subject report) is now "Parcel 3" in the revised grading plans. All conclusions and recommendations for these parcels will also remain the same as indicated in our original report. 4. All cut slope construction and stabilization for the project development should be completed under inspection and testing of the project soils engineer and /or geologist. Additional recommendations should be provided at the time of grading and earth works, based on the actual exposure, if it becomes necessary. Asphalt pavement structural section design should be given in the final rough graded compaction report based on actual testing of subgrade soils. For cost estimating purposes only, please refer to Page 18 of our original report. Should any questions arise concerning this letter, please do not hesitate to contact the undersigned. Reference to our Job #97 -145 -V will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. Addressee (3) Pasco Engineering, Attn c:4tVre1im.197 -145 -v Dennis Middleton CEG #980 fax) �5. GFMID Q CAL VINJE B MIDDLETON ENGINEERING, INC. 2450 Vinryard Avenue, #102. Escondido, California 92029.1229 • Phone (760) 7431214 • Fa: (760) 739 -0343 SOIL TIrIK PERC TEST SOIL IN.ITSlIGATIONS GFOTFCH ICAL IW6ITG•1TIOMG iEC7E0 & SOILS ENGINEER. 25��2 FU i / 1 7.8 , FL LEV. =259.0 25'7.5 ,FL y DEPTH TO BE SOILS ENGINEER DETERMINED BY I J EXISTING GROUND FINISIED SURFACE 2 (TYPE B) _ OEPTH OF FLOW AT 0100. 3• GUNNITE OR A.B.M. / WITH 1.5 X1.5 17 GA, ADE 1.1 STUCCO PETTING. 5Emm0N -B No NO SCALE FILL PER SOILS 'S RECD NDATIONS T 20.0 DE DATE B� r, ■,p w,do CHISELED S0. TOP HDWALL MARKED W/ HORIZONAL 1 ^ ~ STEEL FENCE POST AT SW COR. INT. EL CAMINO DEL NORTE 6 RHO SANTA F RD. 23' W OF RHO SANTA FE RD. 6 VERTICAL "/ 60• S. EL CAMINO DEL NORTE C.L. Fl_. 119.476. DATUM: M.S.L. 3 0-.t ✓ r4tr s�eor Z-p— COST ESTIMATE FOR: ABBASI GRADING PLAN PUBLIC WATER LINE (OMWD EXT. 149 -E) PUBLIC SEWER LINE (CSD 272) PREPARED FOR: ZAHOOR ABBASI PE 718 PREPARED BY: n PASCO ENGINEERING, INC. D l 535 NO. HIGHWAY 101, STE. A Q' SOLANA BEACH, CA 92075 (619) 259 -8212 7/24/98 16:09 c z 0 0 IVo.29577 9 1 Exp.3131199 � :CAI Zda 0� 2-Y Y/ WAYNE PASCO, RCE 295 ATE PE 718 7/24/98 TOTAL $13,317.70 GRAND TOTAL $329,34330 8- t;>- p s. GP DWG. NO. 5452 -G PRIVATE GRADING AND DRAINAGE BOND ESTIMATE CITY OF ENCINITAS ITEM QTY UNIT @ UNIT PRICE TOTAL GRADING: EXCAVATION /EMBANKMENT 16900 CY @ $3.70 $62,530.00 SUB TOTAL $62,530.00 10% CONTINGENCIES $6,253.00 TOTAL $68,783.00 DRAINAGE: 6" AC BERM TYPE "A" 2522 L. F. @ $13.00 $32,786.00 3" AC PAVING 24700 S. F. @ $1.60 $39,520.00 4" AC /6 "AB 14000 S. F. @ $2.00 $28,000.00 CONC. LINED TRAP. CHANNEL 220 CY @ $25.00 $5,500.00 CONCRETE BROW DITCH D -75 3140 L. F. @ $13.00 $40,820.00 STREET NAME SIGN 1 EA @ $180.00 $180.00 18" PVC OR RCP 80 L. F. @ $73.00 $5,840.00 24" PVC OR RCP 83 L. F. @ $84.00 $6,972.00 36" PVC OR RCP 110 L. F. @ $130.00 $14,300.00 12 "X12" BROOKS CATCH BASIN 2 EA @ $500.00 $1,000.00 24 "X24" BROOKS CATCH BASIN 1 EA @ $700.00 $700.00 TYPE "F" CATCH BASIN 1 EA @ $3,280.00 $3,280.00 GRAVITY HOWL PER D -32 7 EA @ $2,200.00 $15,400.00 WING TYPE HOWL PER D -34 4 EA @ $3,780.00 $15,120.00 8" PVC STORM DRAIN 160 L. F. @ $34.00 $5,440.00 12" PVC OR RCP 137 L. F. @ $34.00 $4,658.00 D -22 DOWNDRAIN 240 L. F. @ $15.00 $3,600.00 D -40 RIP RAP 11 C.Y. @ $150.00 $1,650.00 SUB TOTAL $224,766.00 10% CONTINGENCIES $22,476.60 TOTAL $247,242.60 EROSION CONTROL: GRAVEL BAGS 4000 EA @ $1.00 $4,000.00 HYDROSEED SLOPE PROTECTION 73700 SF @ $0.11 $8,107.00 SUB TOTAL $12,107.00 10% CONTINGENCIES $1,210.70 TOTAL $13,317.70 GRAND TOTAL $329,34330 8- t;>- p s. PE 718 7124298 W.L. EXTENSION NO. 149 -E PUBLIC WATER BOND ESTIMATE OLIVENHAIN MUNICIPAL WATER DISTRICT ITEM ' QTY UNIT (a) UNIT PRICE TOTAL WATER (OMWD): 8" PVC CL 200 417 LF @ $33.00 $13,761.00 8" STD. WT. CML &C STEEL PIPE 10 LF @ $50.00 $500.00 2" MANUAL AIR RELEASE 1 EA @ $1,100.00 $1,100.00 2" BLOWOFF 1 EA @ $1,100.00 $1,100.00 FIRE HYDRANT 1 EA @ $3,000.00 $3,000.00 1" DOMESTIC SERVICE 5 EA @ $800.00 $4,000.00 SUB TOTAL $23,461.00 4% CONSTRUCTION STAKING $938.44 15% CONTINGENCIES $3,519.15 TOTAL $27,918.59 RECOMMEND $28,000.00 CS -272 PUBLIC SEWER BOND ESTIMATE CITY OF ENCINITAS SEWER PE 718 7124198 8" PVC SDR -35 425 LF @ $31.00 $13,175.00 TRENCH RESURFACING 20 LF @ $11.50 $230.00 CONCRETE ENCASEMENT (S -7) 20 LF @ $18.00 $360.00 4" LATERAL 5 EA @ $730.00 $3,650.00 MANHOLE 4 EA @ $2,200.00 $8,800.00 SUB TOTAL $26,215.00 10% CONTINGENCIES $2,621.50 TOTA 828,836.50 �� ASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (619) 259 -8212 FAX (619) 259 -4812 July 20, 1998 City of Encinitas 505 So. Vulcan Avenue Encinitas, CA 92024 Attn: Blair Knoll RE: PRIVATE ROAD CERTIFICATION (TPM 97 -201) Dear Mr. Knoll: PE 718F NE A. PASCO .)=,. X9577 Please be advised that the existing private road of access (Double LL Ranch Road) to the above referenced project is within the easement for the benefit of the land division. If you have any questions regarding the above, please do not hesitate to contact us. Very truly yours, PASCO ENGINEERING, INC. Joe Yuhas, L.S. 5211 Director of Land Surveying JY /j s a, 4 HYDROLOGY & HYDRAULIC REPORT Ie1:7 ZAHOOR ABBASI P.O. BOX 462885 ESCONDIDO, CA 92046 -2885 PREPARED BY: PASCO ENGINEERING, INC. 535 NO. HIGHWAY 101, STE. A SOLANA BEACH, CA 92075 Q '6VESS /0Nq A No.29577 cr Exp. 3/31/99 EXP. 3131199 �V- 446w�� WAYNE PASCO, RCE 29577 1V" Mp .. aFRV1GES TABLE OF CONTENTS IINTRODUCTION ......................................................... ..............................1 IIDISCUSSION ................................................................ ..............................1 IIICONCLUSION .............................................................. ..............................1 IV HYDROLOGY CALCULATIONS ............................ ...........................2 -22 V HYDRAULIC CALCULATIONS ....................... ............................... 23- 27 VIAPPENDIX ........................................................... ............................... 2$- �50 VIIEXHIBIT •' A .. ...................................................................................... .: -j! - 3Z i I. INTRODUCTION The purpose of this report is to address the impact that storm runoff has on the proposed development of Lot 6 of Map 13320. Lot 6 is geographically located at North 33 003'45" latitude and West 117 °13'15" longitude. It is physically located on the southside of Double LL Ranch Road, approximately 800 feet west of Lone Jack Road. Based on the information contained in this report, recommendations will be made as to the size and type of drainage structure to be used and shown on the grading plan fog TM 97 -201. II. DISCUSSION The development of Lot 6 consists of 5 graded pads with a private access road off of Double LL Ranch Road and private driveways to access each pad. The nature of the development requires fairly remote pads with long driveways that traverse the drainage areas and swales. Therefore, the drainage structures proposed on the grading plan consist of D -75 brow ditches, headwalls, short culverts, and rip -rap. All of the culverts are inlet controlled. The Hydrologic Soils Group for the entire project is "D" and the rural area runoff coefficient is 0.45. Refer to the hydrology calculations and exhibit "A" for runoff calculations and the drainage area map showing the node locations. Refer to hydraulic calculations for the headwater pipe sizing sheet. Each culvert is identified by node and corresponds to exhibit "A ". Refer to the appendix for supporting documents. III. CONCLUSION Based on the data and calculations contained in this report, it is the professional opinion of Pasco Engineering that the storm drain structures as proposed on the corresponding grading plan will adequately intercept, contain and convey Q10() to an appropriate discharge point. A IV HYDROLOGY CALCULATIONS 2 tf• fffrr+ rfrrffr* wwrxwxw !!ltffrt :rrt +rrffwwxxwwr + ■x!l rterrtrr +x + +rrwwxx!!!rt RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT 1985,1981 HYDROLOGY MANUAL (c) Copyright 1982 -92 Advanced Engineering Software (aes) Ver. 1.3A Release Date: 3/06/92 License ID 1388 Analysis prepared by: Pasco Engineering, Inc. 535 Norht Hwy. 101, Suite A Solana Beach, CA 92075 Ph. (619) 259 -8212 Fax (619) 259 -4812 ---------------------------------------------------------------------------- FUE NAME: 7i0.DAT TIME /DATE OF STUDY: 9:45 2/17/1998 ---------------------------------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: 1985 SAN DIEGO MANUAL CRITERIA USER SPECIFIED STORM EVENT(YEAR) = 100.00 6 -HOUR DURATION PRECIPITATION (INCHES) = 2.900 SPECIFIED MINIMUM PIPE SIZE(INCH) = 3.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE _ .95 SAN DIEGO HYDROLOGY MANUAL "C "- VALUES USED NOTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED FLOW PROCESS FROM NODE 126.00 TO NODE 124.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>> RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< -------------------------- -------------------------- SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW - LENGTH - 240.00 UPSTREAM ELEVATION = 334.00 DOWNSTREAM ELEVATION - 319.00 ELEVATION DIFFERENCE = 15.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 9.841 *CAUTION: SUBAREA SLOPE EXCEEDS COUNTY NOMOGRAPH DEFINITION. EXTRAPOLATION OF NOMOGRAPH USED. 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.937 SUBAREA RUNOFF(CFS) _ .69 TOTAL AREA(ACRES) _ .31 TOTAL RUNOFF(CFS) _ .69 ++++++++++ tw+ xxxw+ wxxxrxxtrfrrr+ rffrrtrttrl rr +xx + + + + + +wwxxw + + + + + + +rr +wx + + + ++ FLOW PROCESS FROM NODE 126.00 TO NODE 124.00 IS CODE 1 - — ---------------------------- --------- --- --- --- ---- --- - - - - -- — - ----- - - - - -- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< ------------------ - - - - -- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 9.84 RAINFALL INTENSITY(INCH /HR) = 4.94 TOTAL STREAM AREA(ACRES) = .31 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .69 wff wf xwrrf # #f + + + + + + + + #f wwr +ffffxxxtf xwwxw #r4 + + + + ++ *rw :r +f xxr ++ #wf 4f+4ff xf # :+ FLOW PROCESS FROM NODE 125.00 TO NODE 124.00 IS CODE = 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 150.00 UPSTREAM ELEVATION = 318.80 DOWNSTREAM ELEVATION = 317.30 ELEVATION DI;7ERENCE = 1.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 14.330 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.874 SUBAREA RUNOFF(CFS) _ .51 TOTAL AREA(ACRES) = .29 TOTAL RUNOFF(CFS) _ .51 ff 4f ## # #f # # #f * # # # *#f #fx4 # # * # #f #off 4* f4*! 4** 4* *4 *ff * * * *t # # # * # #f #k#4 ##x # #tttt# FLOW PROCESS FROM NODE 125.00 TO NODE 124.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE <<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 14.33 RAINFALL INTENSITY(INCH /HR) = 3.87 TOTAL STREAM AREA(ACRES) = .29 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .51 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 .69 9.84 4.937 .31 2 .51 14.33 3.874 .29 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 1.09 9.84 4.937 2 1.05 14.33 3.874 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 1.09 Tc(MIN.) = 9.84 TOTAL AREA(ACRES) = .60 u. A wwwrrtwwww+ i* wwwwxwwwrww++ xxxxxewwwwxxw++ xxxxxxwx •wxxxxx + + + + +xwxx +xxxx +xxxxx FLOW PROCESS FROM NODE 124.00 TO NODE 122.00 IS CODE = 4 ------ - ----- -- >>>>> COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING USER - SPECIFIED PIPESIZE<<<<< DEPTH OF FLOW IN 24.0 INCH PIPE IS 2.0 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 8.9 UPSTREAM NODE ELEVATION - 316.30 DOWNSTREAM NODE ELEVATION = 307.80 FLOWLENGTH(FEET) = 50.00 MANNING'S N .015 GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.09 TRAVEL TIME(MIN.) _ .09 TC(MIN.) = 9.93 rxiwxrwxrt+* wwf• wwwxwwwwxxwwxw* i *rwwwRfwrrf #iarw +wwwwwxwwxxwxxx ww + +twiwwwwxw FLOW PROCESS-FROM NODE 124.00 TO NODE 122.00 IS CODE = 1 ---------------------------------------------------------------------------- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE <<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 9.93 RAINFALL INTENSTTY(INCH /HR) = 4.91 TOTAL STREAM AREA(ACRES) = .60 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.09 * RR** RRRRRRfft# tt4ittittRRk# RRRfR 4RRkRi## i### kR * * * * * * * * * * * *Rkwwwxwxixxw * * * #* FLOW PROCESS FROM NODE 123.00 TO NODE 122.00 IS CODE - 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW - LENGTH = 100.00 UPSTREAM ELEVATION = 309.80 DOWNSTREAM ELEVATION = 308.80 ELEVATION DIFFERENCE = 1.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 11.700 100 YEAR RAINFALL INTENSITY(INCH /HOUR) - 4.416 SUBAREA RUNOFF(CFS) _ .30 TOTAL AREA(ACRES) _ .15 TOTAL RUNOFF(CFS) _ .30 tftt *rirwwrxwwwwwwwww wwwwwwwwwwwrrwwwwrwrirrwxrrrxww # +wrrrffwxiixrrwwrwwwwr• FLOW PROCESS FROM NODE 123.00 TO NODE 122.00 IS CODE = 1 ------------ - >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< » »>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 11.70 RAINFALL INTENSITY(INCH /HR) - 4.42 TOTAL STREAM AREA(ACRES) = .15 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .30 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.09 9.93 4.907 .60 2 .30 11.70 4.416 .15 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. f* PEAK FLOW RATE TABLE f+ STREAM RUNOFF Tc INTENSITY NUMBER (CPS) (MIN.) (INCH /HOUR) 1 1.35 9.93 4.907 2 1.27 11.70 4.416 CQMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) 1.35 Tc(MIN.) 9.93 TOTAL AREA(ACRES) _ .75 r :rrrrrrrrfrrfff +*rf *xfrxrww *rf of +ff *xrrtfrarr+rff * *ww *ww * + : *f rrtrtft * + *rwww FLOW PROCESS FROM NODE 122.00 TO NODE 120.00 IS CODE - 53 >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< >>>>>TRAVELTIME THRU SUBAREA <<<<< UPSTREAM NODE ELEVATION = 307.80 DOWNSTREAM NODE ELEVATION 272.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 120.00 CHANNEL SLOPE _ .2983 CHANNEL FLOW THRU SUBAREA(CFS) - 1.35 FLOW VELOCITY(FEET /SEC) = 3.38 (PER PLATE D -6.3) TRAVEL TIME(MIN.) _ .59 TC(MIN.) - 10.53 +++++ x+ f♦ f**♦ xff+*:*a fw*+* f* f+++++*++ r+ aa# k*+ + + + + + + +rxw + + + + +w + *f + ++ +f + + + + + +t FLOW PROCESS FROM NODE 122.00 TO NODE 120.00 IS CODE 1 ---- --- -- --- ------- --- - -- - ------------------------------------------------- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< --------------------------------------------------------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 10.53 RAINFALL INTENSITY(INCH /HR) = 4.73 TOTAL STREAM AREA(ACRES) _ .75 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.35 ffffff## f#!## f1R** * *ff * + + + * + +* *f * *rtrtrtrtflrt #! # *!ffl lf! # #!rtrt! # # *rt! * * *k * * * # # # # ## FLOW PROCESS FROM NODE 121.00 TO NODE 120.00 IS CODE = 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< ---------------------------------------------------------------------------- SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 11.56(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 420.00 UPSTREAM ELEVATION = 350.00 DOWNSTREAM ELEVATION = 272.00 ELEVATION DIFFERENCE = 78.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SUBAREA RUNOFF(CFS) = 6.23 TOTAL AREA(ACRES) = 3.11 TOTAL RUNOFF(CFS) = 6.23 xrtxxrtwxrxrrr rw rrrerl rrl rrrrrr+ r+ xrrtwxrtwrtxrtxrtxxrtrtxrtrtwxxx +rtff :ffff!!x!lrxr + ++: FLOW PROCESS FROM NODE 121.00 TO NODE 120.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE <<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TQTAL NUMBER -OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 11.56 RAINFALL INTENSITY(INCH /HR) = 4.45 TOTAL STREAM AREA(ACRES) = 3.11 PEAK FLOW RATE(CFS) AT CONFLUENCE = 6.23 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.35 10.53 4.727 .75 2 6.23 11.56 4.449 3.11 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CFS) 1 7.21 2 7.50 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) _ Tc (MIN.) 10.53 11.56 ESTIMATES 7. 3.86 INTENSITY (INCH /HOUR) 4.727 4.449 ARE AS FOLLOWS: 50 Tc(MIN.) = 11.5E wwwi+ rtwtl r!l fxl rrl rlrkiirrrtlr!!!!lflxwxxwxwxwrrw rrrtrt ++ + + +r + + +r +rl +r + + +++r+ FLOW PROCESS FROM NODE 120.00 TO NODE 12.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 4.38 SUBAREA RUNOFF(CFS) = 8.77 TOTAL AREA(ACRES) = 8.24 TOTAL RUNOFF(CFS) = 16.27 TC(MIN) = 11.56 MW wxwxxxffxrr! ► +rr ►tx txfx + + + +r #twwllr of r►►trt ♦xft +txx + + #xxxxxxw•!!f r ►rrrtfa : +x FLOW PROCESS FROM NODE 129.00 TO NODE 127.00 IS CODE = 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) . 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT . .4500 SUBAREA AREA(ACRES) .27 SUBAREA RUNOFF(CFS) . .54 TOTAL AREA(ACRES) 8.51 TOTAL RUNOFF(CFS) = 16.81 TC(MIN) . 11.56 # # + +wxxw +wxx # # #ww #wxww #xxxwxxw xrr►l►►l► rl wrxxtxxtxxxffxf + # + +wxwxtwxxrx!•!r!r FLOW PROCESS FROM NODE 128.00 TO NODE 127.00 IS CODE 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT . .4500 SUBAREA AREA(ACRES) _ .21 SUBAREA RUNOFF(CFS) . .42 TOTAL AREA(ACRES) = 8.72 TOTAL RUNOFF(CFS) = 17.23 TC(MIN) = 11.56 «« x«+ r+ ttrt++ t +xx + +t +t + +tlt + +rtrrr :r « + « «« «rtf rr«r +« « « «xr +tr +t + + :rtrtw « « «x «xx FLOW PROCESS FROM NODE 118.00 TO NODE 119.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL= INTENSITY (INCH /HOUR) = 4.449 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT - .4500 SUBAREA AREA(ACRES) _ .21 SUBAREA RUNOFF(CFS) _ .42 TOTAL AREA(ACRES) = 8.93 TOTAL RUNOFF(CFS) = 17.65 TC(MIN) - 11.56 txff►►« rtrf!!l xRRxxxxRxxw# wl xxxxww#### w###### # # # # #irlrr#4 «rr +rf! ♦fxr «r ♦ «x « «! FLOW PROCESS FROM NODE 12.00 TO NODE 11.00 IS CODE 3 ---------------------------------------------------------------------------- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA« «< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON- PRESSURE FLOW) <<<<< DEPTH OF FLOW IN 21.0 INCH PIPE IS 13.5 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.8 UPSTREAM NODE ELEVATION = 230.00 DOWNSTREAM NODE ELEVATION - 222.00 FLOWLENGTH(FEET) = 100.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 21.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 17.65 TRAVEL TIME(MIN.) _ .15 TC(MIN.) = 11.72 +txxxxrr tt: t+ ttt«« r«« atr+ xx+« xt+ ttxxxxx# xxxxxxr +tr +r + +r #t +r +r +r #r #rxxxxx #xx« FLOW PROCESS FROM NODE 12.00 TO NODE 11.00 IS CODE = 1 --------------------------- ------- - - - - -- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< ------------------------------------------ --------- -- -- --- -------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 11.72 RAINFALL INTENSITY(INCH /HR) = 4.41 TOTAL STREAM AREA(ACRES) = 8.93 PEAK FLOW RATE(CFS) AT CONFLUENCE = 17.65 fxx+ frrrr+ r++ rrrr+ r++ r:+ xxffixffeffxx# xx### xxwxxxxxxxxfrr + + +r # # # #ilwwxwwwww# FLOW PROCESS FROM NODE 111.00 TO NODE 11.00 IS CODE = 21 _- ________ >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 150.00 UPSTREAM ELEVATION = 258.80 DOWNSTREAM ELEVATION = 257.30 ELEVATION DIFFERENCE = 1.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 14.330 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.874 SUBAREA RUNOFF(CFS) _ .66 TOTAL AREA(ACRES) _ .38 TOTAL RUNOFF(CFS) _ .66 fiilltf# f* ffiiiiif# iikfii11f1111w11i11ifY1ik11 #1w111111Rf1R111RRt111w #1i#1i# FLOW PROCESS FROM NODE 111.00 TO NODE 11.00 IS CODE = 1 --------------- L ------------------------------------------------------------ >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< -- --- --------------------------------=------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 14.33 RAINFALL INTENSITY(INCH /HR) = 3.87 TOTAL STREAM AREA(ACRES) _ .38 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .66 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 17.65 11.72 4.411 8.93 2 .66 14.33 3.874 .38 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 18.23 11.72 4.411 2 16.17 14.33 3.874 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) 18.23 Tc(MIN.) 11.72 TOTAL AREA(ACRES) - 9.31 f wwrw» rx +fr +w + ++ + » *tfrrx + ++ + »* *xwr + »rf rf *w *r *rr »rr+f + ++wfw » »r +r + +rrr wwrr♦ + ++ FLOW PROCESS FROM NODE 11.00 TO NODE 11.00 IS CODE = 8 --- ---- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ----------------------------------------------- ------- ------ ---------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.411 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .59 SUBAREA RUNOFF(CFS) = 1.17 TOTAL AREA(ACRES) = 9.90 TOTAL RUNOFF(CFS) = 19.40 TC(MIN) = 11.72 +rrf r+ frr+ wrrrx»+*» rx+ fr» fr+ f++++ r++ r+ rrfrr + + *f +r +rrrfrrrr }frrrww * #*wiwtf lww FLOW PROCESS FROM NODE 11.00 TO NODE 10.00 IS CODE = 51 ---------------------------------------------------------------------------- >>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW<<<<< >>>>>TRAVELTIME THRU SUBAREA<<<<< ----------------- ---- -- ------- -- --- --------------- --- - - -- UPSTREAM NODE ELEVATION 222.00 DOWNSTREAM NODE-£LEVATION = 219.50 CHANNEL LENGTH THRU SUBAREA(FEET) = 220.00 CHANNEL SLOPE = .0114 CHANNEL BASE(FEET) = 1.00 "Z" FACTOR = 2.000 MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 1.00 CHANNEL FLOW THRU SUBAREA(CFS) = 19.40 FLOW VELOCITY(FEET /SEC) = 6.94 FLOW DEPTH(FEET) _ .96 TRAVEL TIME(MIN.) = .53 TC(MIN.) = 12.25 FLOW PROCESS FROM NODE 11.00 TO NODE 10.00 IS CODE = 10 -- - --------------------- - --- ---- ---- -- - -- -------- - ----- - ---------------- >>>>>MAIN- STREAM MEMORY COPIED ONTO MEMORY BANK # 1 <<<<< +rtr +f *xf wxf r #rkttf iftfr! #f lffr +fitfft * *xwwwx *wk * * # }wwtf rf }yf}#f rftfrflf # }rxf FLOW PROCESS FROM NODE 126.00 TO NODE 314 00 IS CODE 21 -------------------------------------------- co -------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< ------°-------- SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 14.21(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 600.00 UPSTREAM ELEVATION = 331.30 DOWNSTREAM ELEVATION = 314.00 ELEVATION DIFFERENCE = 17.30 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.895 SUBAREA RUNOFF(CFS) = 3.58 TOTAL AREA(ACRES) = 2.04 TOTAL RUNOFF(CFS) = 3.58 N #xfiwtt wt ttttf +if iitf of # * #wxxwwetrtf #ft sf % #4 # #rf +fi * # #wx %flrtf # :if lff♦f!!xf lxt FLOW PROCESS FROM NODE 343.00 TO NODE 342.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW)<<<<< DEPTH OF FLOW IN 9.0 INCH PIPE IS 6.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.0 UPSTREAM NODE ELEVATION = 314.00 DOWNSTREAM NODE ELEVATION = 302.00 FLOWLENGTH(FEET) = 60.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 9.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 3.56 TRAVEL TIME(MIN.) = .10 TC(MIN.) = 14.31 •ffiffl lfiffl ffiflfiffflffifxfifififififi %fifi %t %Yt %% %%Y %Y % %t %tt %f itti %tlti%%%1 klf klfff! FLOW PROCESS FROM NODE 342.00 TO NODE 341.00 IS CODE = 53 >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< >>>>> TRAVELTIME THRU SUBAREA<<<<< -------------------------======= - ------------------_-------------------- UPSTREAM NODE ELEVATION 302.00 DOWNSTREAM NODE ELEVATION = 264.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 150.00 CHANNEL SLOPE _ .2533 CHANNEL FLOW THRU SUBAREA(CFS) = 3.58 FLOW VELOCITY(FEET /SEC) = 4.31 (PER PLATE D -6.3) TRAVEL TIME(MtN.) = .58 TC(MIN.) = 14.89 r+## ffr• rrttxxxfil�# f# f## # #xk # # * # ##fff #rf #x # #x :tatfaafar taa tf # +f %+# # # :f # ## ## ## FLOW PROCESS FROM NODE 342.00 TO NODE 341.00 IS CODE = 8 ---------------------------------------------------------------------------- »»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.779 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .80 SUBAREA RUNOFF(CFS) = 1.36 TOTAL AREA(ACRES) = 2.84 TOTAL RUNOFF(CFS) = 4.94 TC(MIN) = 14.89 FLOW PROCESS FROM NODE 341.00 TO NODE 34.00 IS CODE = 3 ---------------------------------------------------------------------------- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON - PRESSURE FLOW) <<<<< -------------------------------------------------------------------- DEPTH OF FLOW IN 12.0 INCH PIPE IS 7.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 10.1 UPSTREAM NODE ELEVATION = 264.00 DOWNSTREAM NODE ELEVATION = 250.00 FLOWLENGTH(F$ET) = 90.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 12.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 4.94 TRAVEL TIME(MIN.) _ .15 TC(MIN.) = 15.04 f kYf!* R# k* Rkkk//!!!lflf ixY//***** Yf lf!! / / #f /* #kx#f!# *k * # /!! / /likkf k # # *R! /!!♦ FLOW PROCESS FROM NODE 34.00 TO NODE 31.00 IS CODE = 53 _________ _____________ ______ __ __ ___ _ _ _ __ >> >>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW<<<<< >>>>>TRAVELTIME THRU SUBAREA<c<<< --------------------------------------------------- UPSTREAM NODE ELEVATION = 250.00 DOWNSTREAM NODE ELEVATION = 227.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 160.00 CHANNEL SLOPE _ .1437 CHANNEL FLOW THRU SUBAREA(CFS) = 4.94 FLOW VELOCITY(FEET /SEC) = 3.61 (PER PLATE D -6.3) TRAVEL TIME(14IN.) _ .74 TC(MIN.) = 15.78 FLOW PROCESS FROM NODE 34.00 TO NODE 31.00 IS CODE = 10 ---- ------ >>>>>MAIN- STREAM MEMORY COPIED ONTO MEMORY BANK # 2 <<<<< FLOW PROCESS FROM NODE 125.00 TO NODE 322.00 IS CODE = 21 ------------------------------------ ------------------------------- -------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 200.00 UPSTREAM ELEVATION = 318.80 DOWNSTREAM ELEVATION = 316.80 ELEVATION DIFFERENCE = 2.00 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 16.546 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.531 SUBAREA RUNOFF(CFS) _ .56 TOTAL AREA(ACRES) _ .35 TOTAL RUNOFF(CFS) _ .56 ** x** x**** xw* 1x#+ 1f!l wxx* xx+ f*+ x* x1x* lxxrxrrY lY *r! #r! #!lxxrlf } :11f }1f ; } *w ; ;* FLOW PROCESS FROM NODE 322.00 TO NODE 321.00 IS CODE 53 --------------------------------------------- -- --- ------------------ -- - -- - -- >>>>>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW<<<<< >>>>>TRAVELTIME THRU SUBAREA <<<<< ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- UPSTREAM NODE ELEVATION = 316.80 DOWNSTREAM NODE ELEVATION = 276.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 150.00 CHANNEL SLOPE _ .2720 CHANNEL FLOW THRU SUBAREA(CFS) _ .56 NOTE: CHANNEL FLOW OF 1. CFS WAS ASSUMED IN VELOCITY ESTIMATION FLOW VELOCITY(FEET /SEC) = 2.92 (PER PLATE D -6.3) TRAVEL TIME(MIN.) _ .86 TC(MIN.) - 17.40 ++ 11l 1xl fl f!! 1!l wrr+!!!!! wf# ww1wx111 +w +!! +!!lwtff #!rtlrlwlwwxwxw #wf •fx• + #f1: FLOW PROCESS FROM NODE 322.00 TO NODE 321.00 IS CODE 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ----------------------==---------- ----------- ----- -- ------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.418 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .44 SUBAREA RUNOFF(CFS) _ .68 TOTAL AREA(ACRES) _ .79 TOTAL RUNOFF(CFS) = 1.23 TC(MIN) = 17.40 R## wkw!l fft!! 4! w #wwlf #!! #wk # # #w #xf1lf1111R1fl1f 111f1r111!!! #!ftlt #w + #!!rilff FLOW PROCESS•FROM NODE 321.00 TO NODE 32.00 IS CODE = 3 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW) <<<<< --------------------------------------------------------------------- DEPTH OF FLOW IN 6.0 INCH PIPE IS 4.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 8.4 UPSTREAM NODE ELEVATION - 272.00 DOWNSTREAM NODE ELEVATION = 250.00 FLOWLENGTH(FEET) = 90.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) 6.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.23 TRAVEL TIME(MIN.) _ .18 TC(MIN.) = 17.58 t# r+t fttflttttttt exx1x11rf1 #1 # #wwxrf #1 #xx #w #wwlfl+f +!!r! #wwx +ww! # # #wwlw! #ww! FLOW PROCESS FROM NODE 321.00 TO NODE 32.00 IS CODE = 1 -- --------- ---- --- -- -- -- ---- - ---------------------------------------------- >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE <<<<< TOTAL NUMBER OF STREAMS - 2 OONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 17.58 RAINFALL INTENSITY(INCH /HR) - 3.40 TOTAL STREAM AREA(ACRES) _ .79 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.23 xwf!!! fl wxwl f!!l++ rxxxxx# xwwfl wl w!! f!l ffrtt ft lfttrw +rllll + +rt +r•11111fxxflx! FLOW PROCESS FROM NODE 332.00 TO NODE 331.00 IS CODE 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 10.70(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 180.00 UPSTREAM ELEVATION = 319.00 DOWNSTREAM ELEVATION = 270.00 ELEVATION DIFFERENCE = 49.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.677 SUBAREA RUNOFF(CFS) _ .78 TOTAL AREA(ACRES) _ .37 TOTAL RUNOFF(CFS) _ .78 FLOW PROCESS FROM NODE 331.00 TO NODE 33.00 IS CODE = 3 '-- --- -- --- >>>>> COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON- PRESSURE FLOW)<<<<< DEPTH OF FLOW IN 6.0 INCH PIPE IS 3.1 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.6 UPSTREAM NODE ELEVATION = 270.00 DOWNSTREAM NODE ELEVATION = 250.00 FLOWLENGTH(FEET) = 80.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 6.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) _ .78 TRAVEL TIME(MIN.) _ .17 TC(MIN.) = 10.88 FLOW PROCESS FROM NODE 331.00 TO NODE 33.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< -------------------------------------------------------------------- TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 10.88 RAINFALL INTENSITY(INCH /HR) = 4.63 TOTAL STREAM AREA(ACRES) _ .37 PEAK FLOW RATE(CFS) AT CONFLUENCE _ .78 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) • 1 1.23 17.58 3.395 .79 2 .78 10.88 4.628 .37 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF NUMBER (CPS) 1 1.68 2 1.80 COMPUTED CONFLUENCE PEAK FLOW RATE(CFS) TOTAL AREA(ACRES) _ Tc (MIN. 10.88 17.58 ESTIMA' 1 INTENSITY I (INCH /HOUR) 4.628 3.395 PES ARE AS FOLLOWS: 1.80 Tc(MIN.) = 17.58 .16 w x* wr rr# fixf+*** kyryyf +;xr+ :rwrxrrwrr #rr *fi *fi *f *+MxwM * * * * *Mx *Mxwwf #i + * *xx *x FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 53 ---------------------------------------------------------------------------- » »>COMPUTE NATURAL MOUNTAIN CHANNEL FLOW <<<<< »»>TRAVELTIME THRU SUBAREA« «< ---------------------------------------------------------------------------- UPSTREAM NODE ELEVATION = 250.00 DOWNSTREAM NODE ELEVATION = 227.00 CHANNEL LENGTH THRU SUBAREA(FEET) = 150.00 CHANNEL SLOPE = .1533 CHANNEL FLOW THRU SUBAREA(CFS) - 1.80 FLOW VELOCITY(FEET /SEC) - 2.67 (PER PLATE D -6.3) TRAVEL TIME(MIN.) = .94 TC(MIN.) = 18.52 ##**# w# f## f*# wk# w #fkRff #f * \wf \iiitiiit #itf *f+tf iff #f \4ff # \ * * * * * * *wi #f+f ! \f4t FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 11 -------------------------------------- ----- --- ---------- ------ - - - - - -- ---- -- >>>>> CONFLUENCE MEMORY BANK # 2 WITH THE MAIN- STREAM MEMORY<<<<< ** MAIN STREAM CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 1.80 18.52 3.284 1.16 ** MEMORY BANK # 2 CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 4.94 15.78 3.641 2.84 ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 6.56 15.78 3.641 2 6.26 18.52 3.284 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 6.56 Tc(MIN.) 15.78 TOTAL AREA(ACRES) = 4.00 FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE = 12 >>>>>CLEAR MEMORY BANK # 2 <<<<< • wxw\ wwwwxr+ a+++ arrw*+++ aa+*+ r* wfffw *xwwx # #w * #ww +wtat + +w + +a *aat tf tff tf * +fraa FLOW PROCESS FROM NODE 33.00 TO NODE 31.00 IS CODE 8 ------------------------- ------------------------- - - -- -- - - ---------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.641 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 1.22 SUBAREA RUNOFF(CFS) = 2.00 TOTAL AREA(ACRES) = 5.22 TOTAL RUNOFF(CFS) = 8.56 TC(MIN) = 15.78 r+# f## wr# w*# wxwrxrxl rf!#! r## r+##+ wr# w*# rwwrxwrffrffrrtrrrft # : # # #wwwrx!!r! # #r FLOW PROCESS FROM NODE 31.00 TO NODE 30.00 IS CODE 3 ---------------------------------------------------------------------------- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING COMPUTER - ESTIMATED PIPESIZE (NON - PRESSURE FLOW) <<<< DEPTH OF FLOW IN 18.0 INCH PIPE IS 11.0 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.6 UPSTREAM NODE ELEVATION - 227.00 DOWNSTREAM NODE ELEVATION - 225.00 FLOWLENGTH(FEET) = 40.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) - 18.00 NUMBER OF PIPES = 1 PIPEFLOW THRU,SUBAREA(CFS) = 8.56 TRAVEL TIME(MIN.) _ .09 TC(MIN.) = 15.87 ir## lkrrfr## rw # #i #r1f #f #f #!r #wr#rrrrwtf * *rr #f wf lffrt *1tt11tfi#t # # # #r#4r ** * ** FLOW PROCESS FROM NODE 31.00 TO NODE 30.00 IS CODE = 8 ------------------------------------------- -------------- ----------------- - >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.628 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .13 SUBAREA RUNOFF(CFS) _ .21 TOTAL AREA(ACRES) = 5.35 TOTAL RUNOFF(CFS) = 8.77 TC(MIN) = 15.87 FLOW PROCESS FROM NODE 31.00 TO NODE 10.00 IS CODE - 51 ---------------------------------------------------------------------------- >>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW « «< >>>>>TRAVELTIME THRU SUBAREA<<<<< UPSTREAM NODE ELEVATION 225.00 DOWNSTREAM NODE ELEVATION = 219.50 CHANNEL LENGTH THRU SUBAREA(FEET) - 150.00 CHANNEL SLOPE _ .0367 CHANNEL BASE(FEET) - 1.00 "Z" FACTOR = 2.000 MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 2.00 CHANNEL FLOW THRU SUBAREA(CFS) = 8.77 FLOW VELOCITY(FEET /SEC) = 8.76 FLOW DEPTH(FEET) _ .50 TRAVEL TIME(MIN.) _ .29 TC(MIN.) = 16.15 #f fitf# wr## kktltrrrf !!fflxffk #wk *wk # # # # ## # #ttfttwrt ltrffr#ftrr # #f # #f ## #! # # ## FLOW PROCESS FROM NODE 31.00 TO NODE 10.00 IS CODE = 8 »»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.586 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .59 SUBAREA RUNOFF(CFS) _ .95 TOTAL AREA(ACRES) = 5.94 TOTAL RUNOFF(CFS) = 9.73 TC(MIN) - 16.15 +xr + +rr * +wxrwfrlxrf rrrw* rw# r## ww+ r#+ rtrrrawr+ # +wwwrr + + # * +t +wwww #ww #f # #fw #fff FLOW PROCESS FROM NODE 30.00 TO NODE 10.00 IS CODE = 11 >>> »CONFLUENCE MEMORY BANK # 1 WITH THE MAIN- STREAM MEMORY <<<<< ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- ** MAIN STREAM CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 9.73 16.15 3.586 5.94 ** MEMORY BANK # 1 CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (qFS) (MIN.) (INCH /HOUR) (ACRE) 1 19.40 12.25 4.288 9.90 ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CPS) (MIN.) (INCH /HOUR) 1 27.54. 12.25 4.288 2 25.96 16.15 3.586 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 27.54 Tc(MIN.) = 12.25 TOTAL AREA(ACRES) = 15.84 #•ww # *xrr + +r #xrrf fifer# r## w## ww# wx #wrrwr +xrrrffefxttttfff:fffwf wef wffwwf wwxwx FLOW PROCESS FROM NODE 10.00 TO NODE 1.00 IS CODE = 3 » » >COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA« «< >>>>>USING COMPUTER- ESTIMATED PIPESIZE (NON- PRESSURE FLOW) <<<<< DEPTH OF FLOW IN 21.0 INCH PIPE IS 15.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 14.2 UPSTREAM NODE ELEVATION = 219.50 DOWNSTREAM NODE ELEVATION 204.00 FLOWLENGTH(FEET) - 120.00 MANNING'S N = .024 ESTIMATED PIPE DIAMETER(INCH) = 21.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 27.54 TRAVEL TIME(MIN.) _ .14 TC(MIN.) = 12.39 FLOW PROCESS FROM NODE 30.00 TO NODE 10.00 IS CODE = 12 ---------------------------------------------------------------------------- >>>>>CLEAR MEMORY BANK # 1 <<<<< FLOW PROCESS FROM NODE 201.00 TO NODE 202.00 IS CODE = 21 --------------------------------- » » >RATIONAL METHOD INITIAL SUBAREA ANALYSIS <<<<< SOIL CLASSIFICATIONsIS'"D ........... - __= _______ RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 NATURAL WATERSHED NOMOGRAPH TIME OF CONCENTRATION WITH 10- MINUTES ADDED = 12.19(MINUTES) INITIAL SUBAREA FLOW- LENGTH = 450.00 UPSTREAM ELEVATION = 320.00 DOWNSTREAM ELEVATION = 280.00 ELEVATION DIFFERENCE = 40.00 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.300 SUBAREA RUNOFF(CFS) = 3.46 TOTAL AREA(ACRES) = 1.79 TOTAL RUNOFF(CFS) = 3.46 rwwrwwrwwrwwxwwrwwx: xxw»» xf rr} ffff} w* r* x} r+ ttr + + + + +tt + # } # *xww »x + + + +tf + + # + + ++ FJ.OW PROCESS. -FROM NODE 202.00 TO NODE 20.00 IS CODE = 4 --- - - -- >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA <<<<< >>>>>USING USER - SPECIFIED PIPESIZE « «< --------------------------------------------------------------------- DEPTH OF FLOW IN 24.0 INCH PIPE IS 3.8 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 11.0 UPSTREAM NODE ELEVATION = 280.00 DOWNSTREAM NODE ELEVATION = 211.00 FLOWLENGTH(FE�T) = 600.00 MANNING'S N = .015 GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 3.46 TRAVEL TIME(MIN.) = .91 TC(MIN.) = 13.10 •wxiwii *itkRf + * * #Rkf iriiiiirrrrrr *ik # ** * } »ttt #iris #ri +kt # * *# * * # * } * # # # # #wwwrr FLOW PROCESS FROM NODE 202.00 TO NODE 20.00 IS CODE = 8 ------------------ ---------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< ---------------------------------------------------------------------------- ------------------------------------------------------------- ------ 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.105 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) = 1.33 SUBAREA RUNOFF(CFS) = 2.46 TOTAL AREA(ACRES) = 3.12 TOTAL RUNOFF(CFS) = 5.92 TC(MIN) = 13.10 # rlffrf} fff» kfrtr»»» wxwwx} xww#} ff# k # #k # #}f }t # }4f }!f• }tI }f } } #4k * } }f Rw # }xwxrttt FLOW PROCESS FROM NODE 202.00 TO NODE 20.00 IS CODE = 1 ------------------------------- -------------------------------------------- > >>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE « <<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 13.10 RAINFALL INTENSITY(INCH /HR) = 4.11 TOTAL STREAM AREA(ACRES) = 3.12 PEAK FLOW RATE(CFS) AT CONFLUENCE = 5.92 R *R *1fi R1fi * * *ifii i*# i*###t Ri# fiiiiRWR# fi** lfil fl R#!if * *i # * #tt * * * *WW #*rWRRfl1!!! FLOW PROCESS FROM NODE 231.00 TO NODE 23.00 IS CODE - 21 >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS« «< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW- LENGTH = 120.00 UPSTREAM ELEVATION = 258.80 DOWNSTREAM ELEVATION = 257.60 ELEVATION DIFFERENCE = 1.20 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 12.817 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.163 SUBAREA RUNOFF(CFS) _ .56 TOTAL AREA(ACRES) _ .30 TOTAL RUNOFF(CFS) _ .56 *# fr# r* ff** f*##* f# tff* ff R1f* rt* r**#+ ++ +# ##irr *ririx* * * * * *r # # #r ♦r!!f t ►!lfft4r FLOW PROCESS FROM NODE 23.00 TO NODE 22.00 IS CODE = 4 >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING USER - SPECIFIED PIPESIZE« <<< ---------------------------------------------------------------------------- ----------------------------------------------- --------------- ---- DEPTH OF FLOW IN. 24.0 INCH PIPE IS 1.4 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.7 UPSTREAM NODE ELEVATION = 256.60 DOWNSTREAM NODE ELEVATION = 237.00 FLOWLENGTH(FEET) = 100.00 MANNING'S N = .015 GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) _ .56 TRAVEL TIME(MIN.) _ .22 TC(MIN.) = 13.03 rft111w #* #fx +ki if tikfi# RewRRwwwR*######* w# kxx *ixxi + +frx *xr + #+ ++xx+fx # +++if # *i+ FLOW PROCESS FROM NODE 23.00 TO NODE 22.00 IS CODE = 8 ---------------------------------------------------------------------------- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.119 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .25 SUBAREA RUNOFF(CFS) _ .46 TOTAL AREA(ACRES) _ .55 TOTAL RUNOFF(CFS) = 1.03 TC(MIN) = 13.03 FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE 4 -------- - ------------------------------------------------------------------ >>>>>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA<<<<< >>>>>USING USER - SPECIFIED PIPESIZE« <<< ------------- ------- ----------------- --- ---- ------ DEPTH OF FLOW IN 24.0 INCH PIPE IS 2.2 INCHES PIPEFLOW VELOCITY(FEET /SEC.) = 7.3 UPSTREAM NODE ELEVATION = 237.00 DOWNSTREAM NODE ELEVATION = 211.00 FLOWLENGTH(FEET) = 260.00 MANNING'S N = .015 GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1 PIPEFLOW THRU SUBAREA(CFS) = 1.03 TRAVEL TIME(MIN.) _ .60 TC(MIN.) = 13.63 xx+++ w+ r+++ xxxxxxx: rx+ rrrr+ xxxwwxrw+ r+ wtr +a + +txrr +rxxxxxxxwwx + + ++ +xx +r wexxxw FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 8 ----- --- >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<< 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 4.001 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .68 SUBAREA RUNOFF(CFS) = 1.22 TOTAL AREA(ACRES) = 1.23 TOTAL RUNOFF(CFS) = 2.25 TC(MIN) = 13.63 wwxxxxwwxxxxxxxtwxxxwwxxwwxww+ w+++ wxwwwxxtx xttxxwxx :xxr + +rxw +xxxxrwwxr ++ +wwx FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 1 ----- -- >>>>>DESIGNATE,INDEPENDENT STREAM FOR CONFLUENCE<<<<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES <<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 13.63 RAINFALL INTENSITY(INCH /HR) = 4.00 TOTAL STREAM AREA(ACRES) = 1.23 PEAK FLOW RATE(CFS) AT CONFLUENCE = 2.25 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 5.92 13.10 4.105 3.12 2 2.25 13.63 4.001 1.23 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 8.11 13.10 4.105 2 8.02 13.63 4.001 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 8.11 TO MIN.) = 13.10 TOTAL AREA(ACRES) = 4.35 wwewxwtxxxwx+++ xrrxwxxxxtx++ ew++++ r + +rr +rxxwtxxxxxxxxxxxxxxxxwxxxw xxxxxwxxxx FLOW PROCESS FROM NODE 22.00 TO NODE 20.00 IS CODE = 1 >>>>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE<<<<< TOTAL NUMBER OF STREAMS - 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) - 13.10 RAINFALL INTENSITY(INCH /HR) = 4.11 TOTAL STREAM AREA(ACRES) = 4.35 PEAK FLOW RATE(CFS) AT CONFLUENCE = 8.11 rrxxtrtrftrr+ r+ ff+ fffffffffr *rrrr +x *Rx * *xx * *xxxxx *xRxfffef rrrtf : :rrrrrrr *x #! FLOW PROCESS FROM NODE 211.00 TO NODE 21.00 IS CODE 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<< SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 INITIAL SUBAREA FLOW - LENGTH = 250.00 UPSTREAM ELEVATION = 219.80 DOWNSTREAM ELEVATION = 217.30 ELEVATION DIFFERENCE - 2.50 URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) . 18.499 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.286 SUBAREA RUNOFF(CFS) = 1.63 TOTAL AREA(ACRES) = 1.10 TOTAL RUNOFF(CFS) = 1.63 itrfffftftti +til riff!! ff# xx## f# #ff #Rx *!f # #xxR * *Rk ##r *rRtr *RrRr rR * # * # # * #* # # #R FLOW PROCESS FROM NODE 211.00 TO NODE 21.00 IS CODE = 1 ---------------------------------------------------------------------------- »» >DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< >>>>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<<<<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 18.50 RAINFALL INTENSITY(INCH /HR) = 3.29 TOTAL STREAM AREA(ACRES) = 1.10 PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.63 " CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH /HOUR) (ACRE) 1 8.11 13.10 4.105 4.35 2 1.63 18.50 3.286 1.10 RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH /HOUR) 1 9.42 13.10 4.105 2 8.12 18.50 3.286 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 9.42 Tc(MIN.) = 13.10 TOTAL AREA(ACRES) = 5.45 INTERIOR STREET CROSSFALL(DECIMAL) . .020 OUTSIDE STREET CROSSFALL(DECIMAL) .020 SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF . 1 * *TRAVELTIME COMPUTED USING MEAN FLOW(CFS) _ .99 STREETFLOW MODEL RESULTS: STREET FLOWDEPTH(FEET) _ .17 HALFSTREET FLOODWIDTH(FEET) = 2.27 AVERAGE FLOW VELOCITY(FEET /SEC.) = 5.81 PRODUCT OF DEPTH &VELOCITY . 1.00 STREETFLOW TRAVELTIME(MIN) = 2.30 TC(MIN) . 15.64 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.662 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .64 SUBAREA RUNOFF(CFS) = 1.05 SUMMED AREA(ACRES) _ .89 TOTAL RUNOFF(CFS) = 1.51 END OF SUBAREA STREETFLOW HYDRAULICS: DEPTH(FEET) . .20 HALFSTREET FLOODWIDTH(FEET) = 3.82 FLOW VELOCITY(FEET /SEC.) = 5.72 DEPTH *VELOCITY = 1.16 ifiiftifiiifflfif iitittlt### i #f *fffRiifiiiiiiiiiiif111f111f 1f #tttfiifftfff of FLOW PROCESS FROM NODE 3.20 TO NODE 3.00 IS CODE = 8 >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW <<<<< --------------------------------------------- ----------- -- --- --------------- 100 YEAR RAINFALL INTENSITY(INCH /HOUR) = 3.662 SOIL CLASSIFICATION IS "D" RURAL DEVELOPMENT RUNOFF COEFFICIENT = .4500 SUBAREA AREA(ACRES) _ .43 SUBAREA RUNOFF(CFS) _ .71 TOTAL AREA(ACRES) = 1.32 TOTAL RUNOFF(CFS) = 2.22 TC(MIN) = 15.64 END OF STUDY SUMMARY: PEAK FLOW RATE(CFS) = 2.22 Tc(MIN.) = 15.64 TOTAL AREA(ACRES) = 1.32 I mlo7oZi] 0cQuilantomfole7-AU- 1NV &'%& 23 V HYDRAULIC CALCULATIONS A too 168 156 144 132 120 106 rr k kT2 is PPe7 J /c /"4 iF! L PiP6�S )0,000 8,000 EXAMPLE (1) (2) (3) 6. 6000 0•42 Inches (3.5 lost) 5,,000 0. 120 <6 S 4,000 At • H11 g' B toot 4. 3,000 Itl z.s e.a S' R) 2.1 7.4 2,000 (3) 2.2 7.7 4• 00 1. 6.t 1,000 800 84 [4010 0 / C o 72 = 0 z - 60 0 k W E 34 z a o / 48 0 • 100 W z 01 2. > / z so _ a u i / 60 v , / ~o. 42 \ W 0 o SO HW SGA - ENTRANCE ° 10 2 -40 D YPE W � W H 30 P� 4e.ra edge MIN a aROcip 10 bead.all .9 33 27•` a. N`IV 10 w .•y (3) Groan and ' 27 vml.<tIAB 24 B. SL 0PS y4"P%� aep° t'J .7 0 .<al. 121 0 1 n0.0d� 2 I nor l<a.tall� 1 cal. III 4 a.e d. nclind . Mr «qn 0 end. 3 inwt Feted g Ft P 13 A��L 3 1.0 IZ'Nc!`Iz .k.,ur BUREAU Of PUBLIC ROADS JAN. 1963 II -67 2'}' S. 4. 3. A OV L4. do .96PT Ai .. r2 "A'L Otr�N�?66�1 �• r8n0l�'�°�� �•� /•SKI s /.3 FTIf� .•. /s�PVr c.re.taeDa d Z I•yx Z= Z •4FT- .1 7+",o 1, AkID i. i7 >< t, > = 1.76 H N .9 r .9 0.82 -X 3a = 2 .kbFT lk 3(P" DID 6+ Lbcc e ` o•70 X I - o •7d Fr• hW • )zANLoK.N New itr � o,HXr = o•blfr Nrd1 !z•At ad<PAtwss/ .6 1— .6 5 1— .S HEADWATER DEPTH FOR CONCRETE PIPE CULVERTS WITH INLET CONTROL . .. rarrrrrrf rrra++ aarrawa+ rrrrwwwwwwx# rw# wfxwf:l rrlrarrr +rr +xr# +r + +ta +w #wwwxr #r HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -96 Advanced Engineering Software (sea) Ver. 6.1 Release Date: 01/01/96 License ID 1452 Analysis prepared by: Pasco Engineering, Inc. 535 North Hwy. 101, Suite A Solana Beach, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 ------------ ------ ------------------------------- ---------- TIME /DATE OF STUDY: 13:56 5/ 5/1998 rrxaaarf#fffrrrrrrrr!lrrt! DESCRIPTION OF STUDY * * * * *rarrrr +rwttttra +rasa# * Check Maximum Depth of flow in trapezoidal channel * Node 11 to Node 10. Q100 at Node 10 used for this CALC. * 100 year storm. See exhibit A. 5 -5 -98 ms # #w #wwwwwrwrafrrrf ttt ttrrttrtt• ttrttrt+♦ rrrrtrrarw +rr +rr +rrwrrtrrrrtrr + +rr ! R• frfrffr♦! tt!! t�!! f!! f!! w# fftt!! f!l rtxwxx# w # # #r # # # # #w # #ww#Rt! #RtwlxRw #!!!! »»CHANNEL INPUT INFORMATION «« ---- ------------------------------- ------------------------' CHANNEL Z1(HORIZONTAL /VERTICAL) 2.00 Z2(HORIZONTAL /VERTICAL) = 2.00 BASEWIDTH(FEET) = 1.00 CONSTANT CHANNEL SLOPE(FEET /FEET) _ .012500 UNIFORM FLOW(CFS) - 27.50 MANNINGS FRICTION FACTOR = .0150 NORMAL -DEPTH FLOW INFORMATION: ----------------------------------- -------------------------------- ---- — - -- >>>>> NORMAL DEPTH(FEET) = 1.10 FLOW TOP- WIDTH(FEET) = 5.40 -FLOW AREA(SQUARE FEET) = 3.52 HYDRAULIC DEPTH(FEET) _ .65 FLOW AVERAGE VELOCITY(FEET /SEC.) = 7.81 UNIFORM FROUDE NUMBER = 1.703 PRESSURE + MOMENTUM(POUNDS) = 509.24 AVERAGED VELOCITY HEAD(FEET) _ .946 SPECIFIC ENERGY(FEET) = 2.047 CRITICAL -DEPTH FLOW INFORMATION: ----- -------------- --- -------------- ------ — --- -------------- — ---------- — CRITICAL FLOW TOP- WIDTH(FEET) = 6.64 CRITICAL FLOW AREA(SQUARE FEET) = 5.39 CRITICAL FLOW HYDRAULIC DEPTH(FEET) _ .81 CRITICAL FLOW AVERAGE VELOCITY(FEET /SEC.) - 5.10 CRITICAL DEPTH(FEET) = 1.41 CRITICAL FLOW PRESSURE + MOMENTUM(POUNDS) = 450.73 AVERAGED CRITICAL FLOW VELOCITY HEAD(FEET) _ .405 CRITICAL FLOW SPECIFIC ENERGY(FEET) = 1.815 25 . +, a +++++ rwrrrw+ r++ r++l w* wwwxwwfxlfl+ wrrwl+++ 4*** * *xwlR + +r +li *r4r + + + *wwwR + :lwr *+ HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982 -96 Advanced Engineering Software (sea) Ver. 6.1 Release Date: 01/01/96 License ID 1452 Analysis prepared by: Pasco Engineering, Inc. 535 North Hwy. 101, Suite A Solana Beach, CA. 92075 Ph: (619) 259 -8212 Fax: (619) 259 -4812 -------------------- --- ---- -------- --- -- ----- - ----- — --- - - ---- TIME /DATE OF STUDY: 15: 7 5/ 5/1998 * * * * *xwxxw *xlxf!! *f!!f!!!f DESCRIPTION OF STUDY * * * * * *xxxxfw + * + + + + + ++ ** ++e * CHECK DEPTH OF FLOW OF D -75 TYPE "B" DITCH AT WORST CASE. * 5irw Mv, ,s.,r ',s ' * (A6 EM'L S�d/!,r? • ✓� -5 -p //per * ** R** Rd* w* RR* R**** ww* kw** ww##►#####!#* i## i# * # * #i* *4 + # * *Rw * +wwfww #i +4+ + #fR+ * R*** RR* f** R** RRR** k* kwwwR!! f!♦ ffffttil ittitfw *iff #* *! * * * * * *k *ft!!f! * + * + + + ++ >>>>PIPEFLOW HYDRAULIC INPUT INFORMATION <<<< ------ — -----' ---- --- -- _- ---- -- - - -- --------------- - - -- PIPE DIAMETER(FEET) 2.000 PIPE SLOPE(FEET /FEET) _ .0200 PIPEFLOW(CFS) - 3.60 MANNINGS FRICTION FACTOR = .015000 ---------------------------------------------------------------- CRITICAL -DEPTH FLOW INFORMATION: CRITICAL DEPTH(FEET) _ .66 CRITICAL FLOW AREA(SQUARE FEET) _ .912 CRITICAL FLOW TOP- WIDTH(FEET) - 1.884 CRITICAL FLOW PRESSURE + MOMENTUM(POUNDS) - 43.29 'CRITICAL FLOW VELOCITY(FEET /SEC.) = 3.948 CRITICAL FLOW VELOCITY HEAD(FEET) _ .24 CRITICAL FLOW HYDRAULIC DEPTH(FEET) _ .48 CRITICAL FLOW SPECIFIC ENERGY(FEET) _ .91 NORMAL -DEPTH FLOW INFORMATION: ---------------- -- --- --_______________ ________-__----_ -- NORMAL DEPTH(FEET) .49 FLOW AREA(SQUARE FEET) _ .59 FLOW TOP- WIDTH(FEET) - 1.716 FLOW PRESSURE + MOMENTUM(POUNDS) = 49.96 FLOW VELOCITY(FEET /SEC.) = 6.089 FLOW VELOCITY HEAD(FEET) _ .576 HYDRAULIC DEPTH(FEET) _ .34 FROUDE NUMBER = 1.828 SPECIFIC ENERGY(FEET) = 1.06 DESCRIPTION OF STUDY 1t #** # *** * *4ff4rliwfi+ktt4 06 Prepared by Pasco Engineering 5/5/9b PE 718 5/5/98 CALCULATE CAPACITY OF BROOKS CATCH BASINS. FORMULA: Qcap = 3.0(P)(DAl.5) / 2. DIVISION BY 2 ACCOUNTS FOR GRATE. PERIMETER AVAIL HW GRATE FACTOR 0100 (CFS)" P (FT) D (FT)' 2.00 CAPACITY (CFS) INLET TYPE 0.78 4.00 0.50 3.00 1.41 12" x 12" BROOKS CB 1.23 4.00 0.50 3.00 1.41 12" x 12" BROOKS CB 0.5 FT. DEPTH ALLOWS FOR 0.5 FT. FREEBOARD IN D -75 DITCH. "- SEE EXHIBIT "A" NODE 321 AND 331 FOR THESE Q100 VALUES. 27 a j a VI APPENDIX D COUNTY OF SAN DIEGO DEPARTMENT OF SANITATION FLOOD CONTROL ICy�'Y�6a l� tiY�D�G� P�d�b ��laT�tsiU '-20-/ ISOPLUVIALS OF 100 -YEAR 6-HOUR PRECIy i T ATION IN 1 INTI;S 01 AN IlXC;I 33° 4$1 301 , 151 451 P..y. U.S. DEPARTME1, NATIONAL OCEANIC AND AT! SPECIAL STUDIES URANCH• OFFICE OF It 301 _ 118, 451 301 151 117° 1151 301 151 116' COUNTY OF SAN DIEGO DEPARTMENT OF SANITATION 100 -YEAR 24410.1 It PRECIPITATION ' b. FLOOD CONTROL - 20./lS9PLUVlALS Of 100 -YEAR 24-IIOUR PRECIPITATION IN - ENTIIS OF AN INCA 451 / toccu J • 100 ',!-PI;o I SD�.r � � " �• 1 `1 - e `tACIIAIII •C 80 �• c Sncl 1 60 -t Idu 301 0 SAN CL MENIE • r D�� I J %• IOU .._ •.7A 74 X45 1�� t i on t)k I - - J.)I� ^ - ' X20 „ - ` - jl` -- `t - `�•- %! i l � o �. • i ,NSIm. I' ,.,100. 1 , i5.� i 5D " Ir[ mr• j I )� ' �� . l 1(,70 , - 1 ( 70 - '7 r IV. , 451 _— ,r .- t �` —{ — J 100_..__ �- c U.S. DEPARTAtEN I. OF COMMERCE ' 70 I �i1 r t� , '�'a "t�I t' 50 \rq NATIONAL OCLANIC AND AT' 051- 11ENIC ADMINISTRATION SPECIAL f7VOlEf DRAM CII, OFFICE 0I II UROLOGY. NATIONAL R'EATIIER SERVICE SA 65110 ~ JO L--- S aYGU 0 "BOiO "5'!0'" I 30' - 30' 1 �' 117' 4!�' 301 151 116 O w A I10 VII EXHIBIT "A" 3/ 7 VINJE & MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, x102 Escondido, California 92029 -1229 Job 97 -145 -V April 28. 1998 O Development Planning Consultants International. Inc. MAY - 81998 Attention: Mr. Zahoor Abbasi 131 South Escondido Boulevard Escondido, California 92025 Clarification Letter On Preliminary Geotechnical Investigation Report Job #97- 145 -V, Dated May 27, 1997, Double LL Ranch Road, Olivenhain Phone(760)743.1214 ;W(760) 739 -0343 The tentative map included in the above referenced geotechnical report has been revised with respect to parcel numbers. Therefore the following clarifications are appropriate: 1. Cut slopes in Parcel 1 and any other cut slopes within the project development exceeding five feet in maximum vertical height and exposing weaker claystone /siltstone units should be reconstructed as a stabilization fill slope at 2:1 gradients maximum as recommended in the project geotechnical report. 2. The previously addressed Parcel 3 (page 11 of the subject report) is now Parcel 2 in the revised map. The east end of the cut slope construction for this parcel may also expose weaker claystone units. In these areas where slope heights exceeds 5 vertical feet maximum. the cut bank may also reconstructed as a stabilization fill slope at 2:1 gradients. 3. All cut slope construction and stabilization for the project development should be completed under inspection and testing of the project soils engineer. Additional recommendations should be provided at time of grading and earth works based on the actual exposure. if it becomes necessary. Should any questions arise concerning this letter, please do not hesitate to contact the undersigned. Reference to our Job #97 -145 -V will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. Dennis Middleton CEG #980 Distribution: Addressee (2) Pasco Engineering, Attn: Mr smslwpdocsl97-1 45-Vc1r prelim Mehdi Shariat RCE #46174 Wayne Pasco (2, fax) No 46174 TO: FROM: RE: ENGINEERING SERVICES DEPARTMENT Capitol Improvement Projects city Of District Support Services Encinitas Field Engineering Subdivision Engineerng Traffic Engineering Field Clearance to Allow Occupancy Subdivision Engineering Public Service Counter Field Operations Private Contract Inspection Building Permit No. JO Name of Project Name of Developer. TRE5 V� sz4s RM G7 Gle IleV- �3�� Oa lfe T � V /5771-5 I have inspected the site at . (address... number ...street name ..sufx) and have determined that finish (precise) grading and Tip t —no Fbl—dgnO any other related site improvements are substantially complete and that occupancy is merited. i5ignature of Senior Civil Engineer, only if appropiate) Reference: Engineering Permit No. 5`1- E 7 --2-7 - -- 01 (Date) (Date) Special Note: Please do not sign the "blue card" that is issued by Building Inspection Division and given to the developer. You are only being asked to verify field conditions. Office staff still has the responsibility to verify that compliance with administrative requirements is achieved, typically payment of impact fees or execution of documents. Return this form, if completed, to counter staff merely by dropping it in the slot labelled "final inspection" that is located between the desks of the engineering technicians. Also, please remember to do final inspections on the related engineering permits and return that paperwork, if completed. Thank you. JSG /fteld.docl rn vn.6ts -)60n 1 FAX ?60- 633 -2627 505 S. Vulcan Avenue. Encinias, California 92024 -3633 TDD 7,60-633-1700 :!� recYciedpaper FROM ENGINEERING SERVICES DEPARTMENT city of Copilot Improvement Projects District Support Services Encinitas Field Operations Subdivision Engineering Troftic Engineering Field Clearance to Allow Occupancy Subdivision Engineering Public Service Counter Field Operations Private Contract Inspection RE: Building Permit No. DD --,267 Name of Project eaLfe Tres VI5TAc, Name of Developer I have inspected the site at 3371 Oail(e TreS VsT +s (address. ..number ...street name .- suffix) I Irce- 3 and have determined that finish (precise) grading and (lot no.) (bldg. no.) any other related site improvements are substantially complete and that occupancy is merited. 5 - -- 7 - -- o/ (Date) fSignature of Senior Civil Engineer, only if appropiate) fDatel Reference: Engineering Permit No. 6452 G.l Special Note: Please do not sign the "blue card" that is issued by Building Inspection Division and given to the developer. You are only being asked to verify field conditions. Office staff still has the responsibility to verify that compliance with administrative requirements is achieved, typically payment of impact fees or execution of documents. Return this form, if completed, to counter staff merely by dropping it in the slot labelled "final inspection" that is located between the desks of the engineering technicians. Also, please remember to do final inspections on the related engineering permits and return that paperwork, if completed. Thank you. JSG /field.doc I TEL 760- 633 -7600 / FAX 760- 633.2627 505 S. Vulcan Avenue. Encinitas, California 92024 -3633 TDD 760. 633 -2:00 recycled paper TO: FROM ENGINEERING SERVICES DEPARTMENT Capital Improvement Projects City of District Support Services Encinitas bField Engineering Operations Subtlivisn Engineering Traffic Engineering Field Clearance to Allow Occupancy Subdivision Engineering Public Service Counter Field Operations Private Contract Inspection RE: Building Permit No. 00 ---31'9 Name of Project (9a Tes (llsrgs Name of Developer �/h CI aCVe F��ornen �" I have inspected the site at 3375 64-l�e 7-4c.5 / 5' f.s ��Ce / A (address ... number ... svee[-name ...suJ�w Y and have determined that finish (precise) grading and (lot no.l (bldg. no ) any other related site improvements are substantially complete and that occupancy is merited. (Signature of senior civil Engineer, only if appropiate) Reference: Engineering Permit No. 5452 G.r 3 - - -13 - -- of (bate) (Date) Special Note: Please do not sign the "blue card" that is issued by Building Inspection Division and given to the developer. You are only being asked to verify field conditions. Office staff still has the responsibility to verify that compliance with administrative requirements is achieved, typically payment of impact fees or execution of documents. Return this form, if completed, to counter staff merely by dropping it in the slot labelled "final inspection" that is located between the desks of the engineering technicians. Also, please remember to do final inspections on the related engineering permits and return that paperwork, if completed. Thank you. 1SG /field.doc I TEL 760 - 633.2600 1 FAX 760- 633 - 1627 505 S. Vulcan Avenue. Enciniras. California 92024.3633 TDD 760. 633 -2700 1� recycled paper PASCO ENGINEERING, INC. 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858) 259 -8212 FAX (858) 259 -4812 January 24, 2002 City of Encinitas Engineering Services Permits 505 So. Vulcan Avenue Encinitas, CA 92024 l JAN 2 8 2002 PE 718 RE: ENGINEER'S PAD CERTIFICATION FOR PROJECT NO. 97- 201TPM AND GRADING PERMIT NO 5744 -G To Whom It May Concern: Pursuant to section 23.24.3 10 of the Encinitas Municipal Code, this letter is hereby submitted as a Pad Certification Letter for the above referenced lot. As the Engineer of Record for the subject project, I hereby state the rough grading for this lot has been completed in conformance with the approved plan and requirements of the City of Encinitas, Codes and Standards or as shown on the attached plans. 23.24.310(B). The following list provides the pad elevations as field verified and shown on the approved grading plan: Pad Elevation Pad Elevation per plan per field measurement 220.5 220.5 23.24.310(B) 1. Construction of line and grade for all engineered drainage devices and retaining walls has been field verified and are in substantial conformance with the subject - grading plan. VINJE & MIDDLETON ENGINEERING, INC. Job #00 -238 -F AL�GL�►xf►�iI�I�I Mr. Bob Davis 2240 Encinitas Boulevard, Suite #401 Encinitas, California 92024 2450 Vineyard Avenue, x102 Escondido, California 92029.1229 ENS T, n� Phone(760)743.1214 Fax (760) 739.0343 AS- GRADED COMPACTION REPORT FOR THE REMEDIAL GRADING CONDUCTED ON PARCEL #1, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201, LOCATED OFF DOUBLE LL RANCH ROAD In accordance with the Grading Ordinance for the City of Encinitas, this as- graded compaction report has been prepared for the above referenced project. We have completed engineering observations and testing services in conjunction with the grading operations. This report summarizes the results of our tests and observations of the compacted fill. The compacted fill in the subject areas was placed during the period of June 16, 2000 through June 23, 2000. Actual dates are shown on the enclosed compaction test result sheet. The following listed reports were reviewed by this office as part of this project: A. "Update Preliminary Geotechnical Investigation Report and Grading Plan Review' letter prepared by this office, dated December 21, 1998, Job #97- 145 -V. B. "As- Graded Compaction Report For Parcel #1, and Associated Driveway, Tres Vistas Estates, City of Encinitas TM #97 -201, Located Off Double LL Ranch Road ", prepared by this office, dated October 11, 1999, Job #98- 373 -F. C. "Update of Compaction Report and Foundation Recommendations For Parcel #1, Tres Vistas Estates, City of Encinitas TM #97 -201, Located Off Double LL Ranch Road ", prepared by this office, dated May 31, 2000, Job #00- 238 -F. Prior to the removal- recompact grading operations, the previously graded building pad was cleared of vegetation. All questionable loose and compressible soils found in the upper 18 inches were removed to underlying previously compacted soils with an in place density in excess of 90% under the direction of this office, prior to backfilling. As- Graded Compaction Report Remedial Grading, Parcel #1 June 27, 2000 Page 2 Site preparation and grading were conducted in substantial conformance with the Grading Ordinance for the City of Encinitas and our above listed "update" report. All inspections and testing were conducted under the supervision of this office. II. FILL PLACEMENT The backfill was placed in six to eight inch lifts and compacted by means of heavy construction equipment. Field density tests were performed in accordance with ASTM Method D- 1556 -90 sand cone method, as the backfill was placed. The moisture content for each density sample was also determined. The locations of the tests were placed to provide the best possible coverage. The results of our field density tests and laboratory testing indicate that the backfills within the house area plus 10 perimeter were compacted to at least 90% of the corresponding maximum dry density at the tested locations. III. APPROPRIATE LABORATORY TESTS A. Maximum Dry Density Optimum Moisture Tests: The maximum dry density and optimum moisture contents of the different soil types used as compacted fill were determined in accordance with ASTM Method D- 1557 -91. B. Expansion Tests: An expansion test was conducted on a representative sample of the near finish grade soils during the previous grading operations to determine the expansion potential and to provide appropriate foundation recommendations. C. Direct Shear Tests: A direct shear test was also performed on a representative sample of the soils used in the previous grading operations to determine the allowable bearing capacity and to provide retaining wall design parameters. IV. RECOMMENDATIONS A. Foundations, Slab on Grade: All foundation recommendations put forth in our "Update" report dated May 31, 2000, should be adhered to. All other recommendations put forth in our "Update" report dated May 31, 2000, should be adhered to. VINJE B MIDDLETON ENGINEERING, INC. 2450 Vinyard Avaoae, #101, Escondido, Cablomia 92029/229 • Phone (760) 743 -1214 • I= (760) 739.0343 C,EOTECNNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS As- Graded Compaction Report Remedial Grading, Parcel #1 June 27, 2000 Page 3 V. LIMITATIONS Our description of the remedial grading operations, as well as observations and testing services herein, have been limited to those remedial grading operations performed periodically from June 16, 2000 through June 23, 2000. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. This report should be considered valid for permit purposes for a period of six months and is subject to review by our firm following that time. IF ANY CHANGES ARE MADE, PAD SIZE, BUILDING LOCATION, ELEVATIONS, ETC. - THIS REPORT WILL BECOME INVALID AND FURTHER ENGINEERING AND RECOMMENDATIONS WILL BECOME NECESSARY. If you have any questions or need clarification, please contact this office at your convenience. Reference to our Job #00 -238 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. Ralph M. Vinje GE #863 140:°63 E>Ip. 123101 RMV /MS /mpr * fc``bIE�1�` q�OF CP.UF( Distribution: Addressee (4) m pr\fi I Ico n 000-23&f. ag 1 Mehdi Shariat RCE #46174 N,3 46174 )1 :0 UT. 12 "1 -02 Of VINJE B MIDDLETON ENGINEERING, INC. 2450 Vim.�wrd Avenue, 0102, Escondido, California 92029.1229 • Phone (760) 743 -1214 • Fos (760) 739.0343 QUOTECHNICAL INVESTIGATIONS GRADING SUPERWSION PE.RC TESTING ENVIRONMENTAL INESTIGATIONS JOB NO: 00 -238 -F NAME: Mr. Bob Davis LOCATION: Parcel #1, Tres Vistas Estates, Encinitas TEST RESULTS Laboratory Compaction Test Results: Soil Type 7: Tan Fine Silty Sand with Trace Clay Maximum Dry Density: 111.7 pcf Optimum Moisture: 17.5% Field Density Test Results: Removal and Recompact Top 18 Inches Date 2000 Test No. Location Ht. Of Fill In Ft. % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 06/16 1 Bldg. Pad, See Attached Plan For Location -1 21.5 99.5 111.7 89.1 Test Failed 06/19 2 Bldg, Pad, See Attached Plan For Location -1 18.8 100.3 111.7 90.0 Retest #1 O6 /20 3 Bldg. Pad, See Attached Plan For Location -1 19.0 105.6 111.7 94.5 06/21 4 Bldg. Pad, See Attached Plan For Location -.5 16.3 96.9 111.7 86.8 Test Failed 06121 5 Bldg. Pad, See Attached Plan For Location -.5 17.5 101.8 111.7 91.9 Retest #5 06/22 6 Bldg. Pad, See Attached Plan For Location -.5 19.5 103.9 111.7 93.0 06/23 7 Bldg. Pad, See Attached Plan For Location 0 FG 18 1 108.0 111.7 96.7 Bldg. = Building FG = Finish Grade mpANIcontb0-238 -f trt VINJE & MIDDLETON ENGINEERING, INC. Job #99 -390 -F July 10, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, #102 Escondido, California 92029 -1229 Phone (760) 743 -1214 Fax (760) 739 -0343 ADDENDUM TO AS- GRADED COMPACTION REPORT DATED JANUARY 17, 2000 FOR PARCEL #2, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201, LOCATED OFF DOUBLE LL RANCH ROAD In accordance with the Grading Ordinance for the City of Encinitas, this as- graded compaction report has been prepared for the above referenced project. We have completed engineering observation and testing services in conjunction with the grading operations. This report summarizes the results of our tests and observations of the compacted fills. The compacted fills in the subject areas were placed periodically from April 14, 2000 through June 29, 2000. Actual dates are shown on the enclosed compaction test result sheets. After initial grading, a 14 foot portion (7 foot vertical) of the Southerly 2:1 gradient cut slope for parcel #2 was removed and a keystone retaining wall was constructed in order to enlarge the pad. Therefore, remedial grading was needed to accommodate the proposed building, eliminate the cuttfill transition line and provide properly compacted fills for support of the structure. The approximate limits of the regraded areas are shown on the attached drawing. Prior to grading operations, the site was cleared of vegetation. All questionable loose and compressible soils were removed to a maximum depth of 7 feet in the undercut areas and recompacted to a minimum of 90% per ASTM D1557 -91. Indications of adverse soil conditions after last winters rains were evident on the project lot. Therefore, removal and recompaction efforts of the upper 18 inches were also completed on the remaining portions of the previously graded pad. Soils were moisture conditioned to the recommended 3 % -5% over optimum moisture content and recompacted to a minimum of 90 %. Site preparation and grading were conducted in substantial conformance with the Grading Ordinance for City of Encinitas and our "As- Graded" compaction report dated January 17, 2000. All inspections and testing were conducted under the observation of this office. In our opinion, all embankments and excavations were constructed in substantial conformance with the provided grading plan, and are acceptable for their intended use. Addendum, As- Graded Report July 10, 2000 Page 2 Fill was placed in six to eight inch lifts and compacted by means of heavy construction equipment. Field density tests were performed in accordance with ASTM Method D -1556- 90 sand cone method as the fill was placed. The moisture content for each density sample was also determined. The approximate locations of the field density tests are shown on the attached drawing. The locations of the tests were placed to provide the best possible coverage. Areas of low compaction, as indicated by the field density tests, were brought to the attention of the contractor. These areas were reworked by the contractor and retested. The test locations and final test results are summarized on the compaction test result table. The results of our field density tests and laboratory testing indicate that the fills at the site were compacted to at least 90% of the corresponding maximum dry density at the tested locations. All previous recommendations set forth in our January 17, 2000 "AS- GRADED COMPACTION REPORT AND FOUNDATION RECOMMENDATIONS FOR PARCEL #2, AND ASSOCIATED DRIVEWAY" Job #99- 390 -F, should be adhered to. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. Ralph M. Vinje {'a!' GE #863 RMV /MS /mpr�f Distribution: Addressee (6) mprV IcontV9 -390 -f a95 I Af Mehdi Shariz r!r' _* I RCE #46174 t:0. «l i4 E9'.12 -31Q OF VINJE fit MIDDLETON ENGINEERING, INC. 2450 Viroyard A,r ., 1102, E,¢.,.h 1o, Calijmnia 92029 4219 • Phone (760) 743 -1214 • I= (760) 739-0343 QEOTECHNICAL I.NVESTIQATfONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain LABORATORY COMPACTION TEST RESULTS PARCEL #2: Soil Type 2: Olive -Green to Grey Claystone (Bedrock) " Maximum Dry Density: 111.3 pcf Optimum Moisture: 17.8% Soil Type 3: Tan to Brown Fine Grained Sandstone (Bedrock) " Maximum Dry Density: 119.9 pcf Optimum Moisture: 11.2% Soil Type 5: Pale Olive to Tan Sandy Silt, Trace Clay Maximum Dry Density: 118.2 pcf Optimum Moisture: 15.5% Soil Type 7: Tan Silty Fine Sand With Trace Clay Maximum Dry Density: 111.7 pcf Optimum Moisture: 17.5% "From our "Preliminary Geotechnical Investigation" report dated May 27, 1997, Job #97 -145 -V mpr1fi11cont193390-f.p16 VINJE 9 MIDDLETON ENGINEERING, INC. 2450 Vin,y M Avenue, 0102, Escondido, California 92029.1229 • Phone(760)743-1214 • F=(760)739-0343 QEOTECHNICAL INVESTIQATIONS GRADING SUPERVISION PERU TESTI,NQ ENVIRONMENTAL INVESTIQATIONS JOB NO: 99 -390 -F NAME: RMCI Development LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Remedial Grading, Parcel #2 Date 2000 Test No. Location Ht. Of Fill In Ft. % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 04/14 1 West Half Parcel 2, Previous Slope Area -6 19.2 107.7 118.2 91.1 Undercut 7' 04/14 2 West Half Parcel 2 -1 21.2 101.7 111.7 91.0 04/14 3 West Half Parcel 2, Previous Slope Area -4 21.9 105.4 111.3 94.7 04/17 4 West Half Parcel 2, Previous Slope Area -3 17.6 102.7 111.7 92.3 0420 5 West Half Parcel 2, Previous Slope Area -3 22.0 106.1 111.3 95.3 0420 6 West Half Parcel 2, Previous Slope Area -1.5 19.3 101.5 111.7 90.9 0421 7 West Half Parcel 2 0 17.8 105.9 111.7 94.8 Finish Grade 0425 8 East Half Parcel 2, Previous Slope Area -1.5 17.6 102.2 111.7 91.5 Undercut 3' 0425 9 East Half Parcel 2 -1 20.6 97.7 111.7 87.8 Failed 0627 10 East Half Parcel 2 -1 17.8 103.5 111.7 92.7 Retest #9 06/29 11 East Half Parcel 2 0 15.2 1145 119.9 95.5 Finish Grade m pN l Icon 1. \99 -390. f t(5 VINJE & MIDDLETON ENGINEERING, INC. Job 97 -145 -V December 21, 1998 Development Planning Consultants International, Inc. 0 9 Attention: Mr. Zach Abbasi 131 South Escondido Boulevard Escondido, California 92025 tz�< 2450 Vineyard Avenue, #102 S Escondido, California 92029 -1229 Phone(760)743.1214 Fax (760) 739 -0343 %A-41 Updated Preliminary Geotechnical Investigation Report and Grading Plan Review, Job #97- 145 -v, Dated May 27, 1997, Double LL Ranch Road, Olivenhain In accordance with your request, we have completed the following updated Geotechnical Report for the above referenced project site. Based upon our recent visual inspections, site conditions have primarily remained unchanged since issuance of our original report entitled "Preliminary Geotechnical Investigation, Proposed 5 Parcel subdivision, APN 264 - 240 -03, Double LL Ranch Road, Olivenhain, City of Encinitas, California," Job #97- 145 -V, dated May 27, 1997. All conclusions and recommendations provided in the referenced project soils report, and the subsequent "Clarification Letter on Preliminary Geotechnical Investigation Report, Job #97- 145 -V, Dated May 27, 1997, Double LL Ranch Road, Olivenhain," dated April 28, 1998, remain valid and should be incorporated into the final plans and implemented during the construction where appropriate and applicable. The need for an additional study and /or subsoils investigation is currently not indicated. The following additional pertinent report(s) and plan(s) related to the project site were also reviewed in connection with this updated study: 1W 1. Grading Plan for Remainder Parcel, Tres Vistas Estates, TMP 97 -201, prepared by Pasco Engineering, not dated. 2. Grading Plan for TM 97 -219, prepared by Pasco Engineering, not dated. 3. Response to Consultant Review of 'Preliminary Geotechnical Investigation, Proposed 5 Parcel subdivision, APN 264- 240 -03, Double LL Ranch Road, Olivenhain, City of Encinitas," prepared by Vinje & Middleton Engineering, Inc., Job #97- 145 -V, dated August 1, 1998. Based on our review, the following comments are appropriate: 1. The tentative map included in the above referenced Preliminary Geotechnical Investigation Report, dated May 27, 1997, has been revised with respect to parcel numbers. 2. The previously addressed 'Parcel 3" (page 11 of the subject report) is now 'Parcel 2" in the revised map. The east end of the cut slope construction for this parcel may also expose weaker claystone units. In these areas where slope heights exceed 5 vertical feet Development Planning Consultants International, Inc. Attention: Mr. Zach Abbasi December 21, 1998 Page 2 maximum, the cut bank may also be reconstructed as a stabilization fill slope at 2:1 gradients. , 3. The previously addressed "Parcel 2" (Page 10 of the subject report) is now the Remainder Parcel" and previous "Parcel 4" (Page 11 of the subject report) is no arcel in the revised grading plans. All conclusions and recommendations for these parcels will also remain the same as indicated in our original report. 4. All cut slope construction and stabilization for the project development should be completed under inspection and testing of the project soils engineer and/or geologist. Additional recommendations should be provided at the time of grading and earth works, based on the actual exposure, if it becomes necessary. 5. Asphalt pavement structural section design should be given in the final rough graded compaction report based on actual testing of subgrade soils. For cost estimating purposes only, please refer to Page 18 of our original report. Should any questions arise concerning this letter, please do not hesitate to contact the undersigned. Reference to our Job #97 -145 -V will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETO Vinje GE #863 Mehdi Shariat RCE #46174 �r. Distribution: Addressee (3) NN Pasco Engineering, Attn: Mr. c:5 t\preIim.\97 -145 -v Dennis Middleton CEG #980 —No. 465174 t ; FY.P. 12 -31 -0 2/ (2, fax) MCN2 -pREo `CAL VINJE & MIDDLETON ENGINEERING, INC. 2450 Viar,asd Asawe, 0102. Esrondido. Califomia 920291229 • Phone (760) 7434214 • Fax (760) 739 -0343 COIL TF_MNQ PE.RC TEST SOIL INVEMQATIONS GEOTEC1 N1C41NVESTICATIONS Job #98 -373 -F (�& I � July 8, 1999 Xion Investments Attention: Mr. Zach Abbasi 375 South Rancho Santa Fe Road, Suite #103 San Marcos. California 92069 R -VALUE TEST RESULTS, PAVEMENT /BASE THICKNESS AND SUB /BASEGRADE RECOMMENDATIONS FOR IMPROVEMENTS TO CALLE TRES VISTAS, AND ON SITE DRIVEWAYS, PROPOSED 5 LOT SUBDIVISION LOCATED OFF DOUBLE LL RANCH ROAD, CITY OF ENCINITAS DRAWING #5452 -G In accordance with guidelines put forth by the City of Encinitas, a representative R -Value sample was obtained from the subgrade soils to determine the thickness of base material required for your improvements. The test results and recommendations are as follows: I. DATA 1. R -Value result is 6. 2. Traffic Index (T.I.) per the City of Encinitas is 5.0 for Calle Tres Vistas, and 4.5 for the on site driveways. 3. Minimum section for a T.I. of 5.0 and 4.5 per the City of Encinitas is 4 inches A. C. over 6 inches Class II aggregate base. II. PAVEMENT /BASE THICKNESS RECOMMENDATIONS A. Calle Tres Vistas: Our calculations indicate that a minimum of 4 inches A.C. over 7 inches Cal Trans Class II aggregate base be used. B. On Site Driveways: Our calculations indicate that a minimum of 4 inches A. C. over 6 inches Cal Trans Class II aggregate base be used. C. Curb and Gutters: Due to the expansive nature of the subgrade soils, expansion index greater than 20, a minimum of 6 inches of Class II aggregate base will be required beneath the curb and gutters. Pavement/Base, Sub /Basegrade Recommendations On Site Improvements, City of Encinitas Drawing # July 8, 1999 Page 2 D. Sidewalks (If Occur): Due to the expansive nature of the subgrade soils, expansion index greater than 20, a minimum of 4 inches Class II aggregate base will be required beneath the sidewalks. III. SUBGRADE RECOMMENDATIONS A. Roadways/Travelways, Driveway Approaches, Trash Enclosure, and Ribbon (Cross) Gutters: The top 12 inches of the subgrade soils are to be moisture conditioned to near optimum moisture content, reworked and recompacted to a minimum of 95% ASTM 1557 -91. B. Sidewalks, Curb and Gutters: The top 6 inches of the subgrade soils are to be moisture conditioned to near optimum moisture content, reworked and recompacted to a minimum of 90% ASTM 1557 -91. C. The subgrade soils are to be proof rolled with a heavy rubber tired vehicle (loaded dump truck or water truck etc.) prior to compaction testing. Areas that show any signs of movement will automatically be failed and will need to be reworked prior to compaction testing. D. Compaction tests will be taken on the subgrade soils to confirm minimum compaction requirements. E. Proper drainage must be maintained at all times so that no water from any source is allowed to infiltrate the subgrade soils, or deterioration of the improvements may occur. IV. BASEGRADE RECOMMENDATIONS A. Roadways /Travelways, Driveway Approaches, Trash Enclosure, and Ribbon (Cross) Gutters: The recommended thicknesses of Class II aggregate base is to be moisture conditioned to near optimum moisture content, reworked and compacted to a minimum of 95% ASTM 1557 -91. B. Sidewalks, Curb and Gutters: The Class II aggregate base is to be moisture conditioned to near optimum moisture content, reworked and recompacted to a minimum of 95% ASTM 1557 -91, except for under sidewalks where a minimum of 90% relative compaction is required. Pavement/Base, Sub / Basegrade Recommendations On Site Improvements, City of Encinitas Drawing # July 8, 1999 Page 3 C. The basegrade soils are to be proof rolled with a heavy rubber tired vehicle (loaded dump truck or water truck etc.) prior to compaction testing. Areas that show any signs of movement will automatically be failed and will need to be reworked prior to compaction testing. D. Compaction tests will be taken on the basegrade soils to confirm minimum compaction requirements. E. The Class II aggregate base should be laid down over the previously prepared subgrade soils as soon as possible so that the subgrade soils are not allowed to dry out. If the subgrade soils are allowed to dry out, further reworking of the subgrade soils will be required. During times of inclement weather, additional inspection of the subgrade soils will be required prior to base placement. If the subgrade soils have become saturated, basegrade soils may not be placed until the subgrade soils have been allowed to dry and are reworked and recompacted to a minimum of 95% ASTM 1557 -91. F. Proper drainage must be maintained at all times so that no water from any source is allowed to infiltrate the basegrade soils, or deterioration of the pavement may occur. G. The Class II aggregate base shall meet or exceed the current Cal Trans Standard Specifications. V. PAVEMENT /CONCRETE RECOMMENDATIONS A. The pavement/concrete should be laid down over the previously prepared basegrade soils as soon as possible so that the basegrade soils are not allowed to dry out. If the basegrade soils are allowed to dry out, further reworking of the basegrade soils will be required. During times of inclement weather, additional inspection of the basegrade soils will be required prior to placement of pave ment/concrete. If the basegrade soils have become saturated, pavement/concrete may not be placed until the basegrade soils have been allowed to dry and are reworked and recompacted to a minimum of 95% ASTM 1557 -91. B. The A.C. pavement materials shall meet or exceed the current Green Book Standard Specifications. Pavement/Base, Sub /Basegrade Recommendations On Site Improvements, City of Encinitas Drawing # July 8, 1999 Page 4 Copies of this report must be submitted to the City of Encinitas Engineering Department for their review and approval. After approval, copies of this report should be provided to the project Civil Engineer and or Architect, and appropriate contractors. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #98 -373 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. RMV /mpr Distribution: Addressee (6) mprlstimprovW- 373-f. pb t CALCULATIONS Job #98 -373 -F Job Name: Xion Investments, Inc. Location: Off Double LL Ranch Road, Encinitas Calle Tres Vistas 1. Data: R = 6; TI = 5.0; Minimum Section = 4" A.C. over 6" Class II Base. 2. Calculations: GE= .0032xT1 x(100- R)= .0032x5.Ox(100 -6)= 1.50 GF: From Cal Trans 1990 Edition, Table #608.4B = 2.54 B = GE - [(AC _ 12)(GF)] = 1.50 - [(4 _ 12)(2.54)] = 1.50 - 0.85 = 0.65 B1 =6x12 =0.65 x12 =8 "Class 111; =1.1 =7 " Class ll Therefore: Use 4 inches AC over 7 inches Class II Base Driveways 1. Data: R = 6; TI = 4.5; Minimum Section = 4" A.C. over 6" Class II Base. 2. Calculations: GE= .0032xT1x (100- R)= .0032x4.5x(100 -6) =1.35 GF' From Cal Trans 1990 Edition, Table #608.46 = 2.54 B = GE - [(AC _ 12)(GF)] = 1.35 - [(4 _ 12)(2.54)] = 1.35 - 0.85 = 0.50 B1= Bx12 =0.5 x12 =6 "Class 111; =1.1 =6 " Class ll Therefore: Use 4 inches AC over 6 inches Class II Base mp0stimprM% -3T -f. rc1 VINJE & MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, #102 Escondido, CA 92029 -1229 Phone: (760) 743 -1214 Fax: (760) 739 -0343 JOB NUMBER 98 -373F CLIENT NAME XION INVESTMENTS 2622 SUNSET DRIVE ESCONDIDO ESCONDIDO 760- 738 -7500 JOB NAME ABBASI JOB LOCATION OLIVENHEIN STREET NAME CALLE TRES VISTAS STATIONING 0 +00 TO 4 +50 SOIL SAMPLE PROVIDED BY: TECH IN FIELD /FRANK DATE SUBMITTED TO LABORATORY: 6 -29 -1999 SOIL DESCRIPTION: LIGHT BROWN SILTY CLAY R -VALUE REPORT NUMBER: RV -91 -99 COMPACTOR PRESSURE - P.S.I. MOISTURE @ COMPACTION - PERCENT DENSITY - POUNDS /CUBIC FOOT R- VALUE - STABILOMETER EXUDATION PRESSURE - P.S.I. COVER THICKNESS BY STABILOMETER (FEET) COVER THICKNESS BY EXPANSION (FEET) T. I. (ASSUMED) BY STABILOMETER @ 300 PSI, EXUD. BY EXPANSION PRESSURE AT EQUILIBRIUM SAND EQUIVALENT R VALUE DATA A B C D 25 50 75 23.5 21.8 20.1 101.0 104.0 106.6 7 9 13 246 390 614 .89 .87 .84 .8 1.1 1.5 4.5 7 6 6 Malcolm/Terry/Mike - FYI Vacations: (Estimated dates as of June 19, 1999) Name Gone From Back to work on Dennis June 22 July 14 + Dodie (estimate) June 25 June 29 Malcolm June 29 July 19 Brad June 30 July 6 Brad July 19 July 26 Emily July 25 Aug. 2 Mehdi (estimate) August 25 Sept. 7 If you know of other, please note and return to me. Thank you. Emily VINJE & MIDDLETON ENGINEERING, INC. Job #99 -390 -F June 15, 2000 RMCI Development, Tres Vistas Estates Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax(760)739 -0343 SUB AND BASEGRADE COMPACTION TEST RESULTS, FOR CALLE TRES VISTAS AND DRIVEWAYS FOR PARCELS #1 THROUGH 44, TRES VISTAS ESTATES, DOUBLE LL RANCH ROAD, OLIVENHAIN In accordance with the Grading Ordinance for the City of Encinitas, this compaction report for the sub and basegrade has been prepared for the above referenced site. We have completed engineering observation and testing services in conjunction with the grading operations. This report summarizes the results of our tests and observations of the compacted sub and basegrade conducted periodically from March 13, 2000 through March 28, 2000. Actual dates are shown on the enclosed compaction test result sheets. A laboratory compaction test for each soil type was performed to determine the maximum dry density and optimum moisture in accordance with ASTM D- 1557 -91. Field density tests were performed in accordance with ASTM D- 1556 -90 sand -cone method. The moisture content for each density sample was also determined. The results of these tests are shown on the attached sheets. The locations of the tests were so placed to provide the best possible coverage. Areas of low compaction, as indicated by the field density tests, were brought to the attention of the contractor. These areas were reworked by the contractor and retested. The test locations and final test results are summarized on the compaction test result table. The results of our field density tests and laboratory testing indicate that the sub and basegrade at the areas tested were compacted to at least the following listed minimum specifications at the tested locations: 1. Sub /basegrade for Calle Tres Vistas and driveways: 95% of the corresponding maximum dry density. Our description of the grading operations, as well as observations and testing services herein, have been limited to those grading operations performed periodically from March 13, 2000 through March 28, 2000. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. Sub and Basegrade Compaction Report RMCI Development, Tres Vistas Estates June 15, 2000 Page 2 If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. Ralph M. Vinje GE #863 RMV /fr Distribution: Addressee (6) mpr\5timprovG9-394f. sb 1 VIN1E B MIDDLETON ENQINEERING, INC. 2450 Vim.yard Avenue, #102, Escondido, California 92029.1219 • Phmm (760) 7431214 • Fax (760) 739 -0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PFRC TESTING ENVIRONMENTAL INVESTIGATIONS JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain LABORATORY COMPACTION TEST RESULTS: Soil Type 1: Dark to Olive Brown Sandy Silty Clay"* Maximum Dry Density: 113.2 pcf Optimum Moisture: 15.5% Soil Type 2: Olive Grey to Green Claystone* Maximum Dry Density: 111.3 pcf Optimum Moisture: 17.8% Soil Type 5: Pale Olive to Tan Sandy Silt With Clay Maximum Dry Density: 118.2 pcf Optimum Moisture: 15.5% Soil Type 7: Tan Fine Silty Sand With Trace Clay Maximum Dry Density: 111.7 pcf Optimum Moisture: 17.5% Soil Type 10: Brown Clayey Silty Sand Maximum Dry Density: 113.6 pcf Optimum Moisture: 17.0% Soil Type 14: Light Brown Silty Sandy Gravel, Class II (Import) Maximum Dry Density: 135.2 pcf Optimum Moisture: 9.2% 'From The Preliminary Geotechnical Investigation Report, By Virile 8 Middleton Eng., Inc., Dated May 27, 1997, Job #97 -145 -V mpr%stimpmN99-390 -f.p11 VINIE 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, 0102, Escondido, California 92029 -1229 • Phone (760) 743.1214 • Fax (760) 739.0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING EM'IRONMENTAL INVESTIGATIONS JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, OLivenhain Field Density Tests Results: Sub and Basegrade Date 2000 Test No. Location Ht. Of Fill In Ft. % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 03/13 1 Driveway, Parcel 2, Sta:2 +96 SG 23.0 108.3 118.2 91.6 Failed 03/13 2 Driveway, Parcels 3 & 4, Sta: 0 +90 SG 21.2 107.3 113.6 94.4 Failed 03/13 3 Driveway, Parcels 3 & 4, Sta: 4 +32 SG 17.4 108.9 113.6 95.9 03/22 4 Driveway, Parcels 3 & 4, Sta: 6 +60 SG 16.4 106.6 111.7 95.4 03!22 5 Driveway, Parcels 3 & 4, Sta: 2 +77 SG 16.8 113.8 118.2 96.3 03/22 6 Driveway, Parcels 3 & 4, Sta: 0 +92 SG 16.9 113.3 118.2 95.9 Retest #2 03/22 7 Driveway, Parcel 1, Sta: 0+90 SG 20.5 104.0 111.3 93.4 Failed 03/23 8 Driveway, Parcel 1, Sta: 3+05 SG 242 102.4 1113 92.0 Failed 03/23 9 Driveway, Parcel 1, Sta: 4+40 SG 16.2 103.8 111.3 93.3 Failed 03/23 10 Driveway, Parcel 1, Sta: 0 +92 SG 15.6 106.0 111.3 95.2 Retest #7 03/23 11 Driveway, Parcel 1, Sta: 4+40 SG 17.0 110.5 111.3 99.2 Retest #9 03/23 12 Calle Tres Vistas, Sta: 0 +70 SG 20.6 107.5 113.2 95.0 Cul -De -Sac 03/23 13 Calle Tres Vistas, Sta: 2 +73 SG 19.0 108.1 113.2 95.5 03123 14 Driveway, Parcel 1, Sta: 3+05 SG 21.2 107.0 111.3 96.1 Retest #8 03/24 15 Driveway, Parcel 2, Sta: 3 +10 SG 20.0 110.4 113.2 97.5 Retest #1 03/24 16 Driveway, Parcel 2, Sta: 1 +75 SG 19.8 108.1 111.3 97.1 03/27 17 Driveway, Parcel 3, Sta: 7+80 BG 8.0 131.0 135.2 96.9 03127 18 Driveway, Parcel 3, Sta: 6+30 BG 8.2 132.7 135.2 98.2 03/27 19 Driveway, Parcels 3 & 4, Sta: 4 +66 BG 8.0 132.9 135.2 98.3 03/27 20 Driveway, Parcels 3 & 4, Sta: 2 +80 BG 8.0 131.9 135.2 97.6 03/27 21 Driveway, Parcels 3&4, Stagy 0 +98 BG 7.8 130.1 135.2 96.2 JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, OLivenhain Field Density Tests Results: Sub and Basegrade Date 2000 Test No. Location Ht. Of Of In Ft. °/U Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 03127 22 Driveway, Parcel 2, Sta: 2+95 BG 8.8 131.3 1352 97.1 03/27 23 Driveway, Parcel 2, Sta: 1 +67 BG 8.0 132.1 135.2 97.8 03/27 24 Calle Tres Vistas, Sta: 4 +05 BG 8.2 131.4 135.2 97.2 Cul -De -Sac 03/27 25 Driveway, Parcel 1, Sta: 0+55 BG 8.0 131.7 135.2 97.4 03127 26 Driveway, Parcel 1, Sta: 2+19 BG 7.5 133.0 135.2 98.4 03/27 27 Driveway, Parcel 1, Sta: 4+50 BG 6.1 132.0 135.2 97.6 03!27 28 Driveway, Parcel 1, Sta: 3+58 BG 7.4 133.0 135.2 98.4 03/28 29 Calle Tres Vistas, Sta: 1 +90 BG 8.1 132.3 135.2 97.9 03/28 30 Calle Tres Vistas, Sta 0 +45 BG 7.5 131.5 135.2 973 SG = Subgrade BG = Basegrade Sta: = Station mprlsub\bas W3W trl VINJE & MIDDLETG_ 4 ENGINEERING, INC. 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 Phone (760) 743.1214 Job #98 -373 -F Fax (760) 739 -0343 May 24, 1999 FEB 2 8 2002 Xion Investments Attention: Mr. Zach Abbasi 375 South Rancho Santa Fe Road, #103 San Marcos, California 92069 DETERMINATION OF CLIMATE CONTROLLED DIFFERENTIAL MOVEMENTS AND GEOTECHNICAL REQUIREMENTS, PROPOSED POSTTENSIONED SLAB -ON- GROUND FOUNDATIONS, REMAINDER PARCEL, CALLE TRES VISTA OFF LL RANCH ROAD, OLIVENHAIN, CALIFORNIA Grading and earthworks for the remainder parcel are near completion and rough finish grades have been primarily achieved. Engineering observations and compaction testing of the controlled fill for the subject site are currently being carried out by our firm as a part of larger development mass grading operations. Geotechnical certification of the cut/fill grading operations, including the results of our observations, ground stabilization efforts and field compaction tests, will be summarized in the forthcoming as- graded compaction report. Our grading observations indicate that "highly" to "very highly" clayey expansive soils occur beneath the remainder parcel. We understand a posttensioned slab -on- ground foundation system is being considered to offset adverse affects of the underlying expansive foundation soils on the proposed residential structure. The purpose of this technical effort was to investigate the underlying foundation bearing soil and provide site specific climate controlled differential movement of expansive clays with the pertinent soil design parameters and geotechnical requirements for the posttensioned slab -on- ground foundation design. EXPLORATORY DRILLING Geotechnical conditions at the project site were determined from grading observations and testing of controlled fill. In -situ soil conditions within the effective foundation bearing zone were additionally evaluated by the excavation of two test borings dug with a truck - mounted drill. The borings were logged by our project geologist who also retained representative soil /rock samples for laboratory testing. Boring locations are depicted on the attached Boring Location Map as Plate 1. Logs of the borings are attached to this report as Plate 2. Mr. Zach Abbasi May 24, 1999 Page 2 Laboratory Testing /Results Earth deposits encountered in our test borings were closely examined and sampled for subsequent laboratory testing. Based upon our test data and field exposures, site soils have been grouped into the following soil types: TABLE 1 Soil Type Description 1 dark to olive brown silty clay ML- CUMH -CH 2 olive green to grey cla stone ML- CUMH -CH 3 tan sandy clayey siltstone (MUMH) The following tests were performed in the support of this study: Maximum Dry Density and Optimum Moisture Content: The maximum dry density and optimum moisture content of representative soil types were determined in accordance with ASTM D- 1557 -91. The test results are presented in Table 2. TABLE 2 Location Soil Type Maximum Dry Density Ym- c Optimum Moisture Content fill (mixture)' 1 113.2 15.5 fill (mixture)' 2 111.3 17.8 fill mixture)' 3 117.7 17.5 indicates that the test was performed during the coarse of grading operations. 2. Moisture - Density Tests: In -place dry density and moisture contents of representative soil deposits beneath the site were determined from undisturbed ring samples using weights and measurements. The test results are presented in Table 5 and tabulated on the attached Boring Logs. VINIE 9 MIDDLETON ENQINEERINQ, INC. 2450 Viney°rd Avmw, #102, Eumdid°, Gd&mia 92029.1219 • Phmm (760) 743.1214 • 1" (760) 739 -0343 QEOTECHNICAL INVESTIQATIONS QRADINQ SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIQATIONS Mr. Zach Abbasi May 24, 1999 Page 3 If-3:11114N Sample Location Soil Type Field Moisture Content W-° /a Field Dry Density Yd- cf Sample Location Ratio of In -Place Dry Density To Max. Dry Density' Yd/Ym x 100 B -1 @ 5' 2 20.4 102.2 111.3 91.8 B -1 @ 10' 2 17.2 108.0 113.2 95.4 B -1 @ 15' 2 20.9 105.8 113.2 93.4 B -2 @ 3' 2 19.1 101.0 111.3 90.7 B -2 9' 3 14.3 117.6 117.7 formational B -2 @ 15' 2 15.8 113.4 111.3 formational 'Designated as relative compaction for structural fills. Required relative compaction for structural fill is 90% or greater. 3. Direct Shear Test: One direct shear test was performed on a representative sample of the foundation bearing soil. The prepared specimen was soaked overnight, loaded with normal loads of 1, 2, and 4 kips per square foot respectively, and sheared to failure in an undrained condition. The test result is presented in Table 4. TABLE 4 indicates that the test was performed during the coarse of grading operations. 4. Expansion Index Test: Four expansion index tests were performed on representative onsite soil samples in accordance with the Uniform Building Code Standard 18 -2. The test results are presented in Table 5. VIN1E B MIDDLEfON ENGINEERINQ, INC. 2450 Vineyard Avenue, #101, Escrosdidu, Culifamia 92029,1229 • Aw. (760) 743.1214 • F" (760) 739 -0343 GEOTECHNICAL INVLTIGATIONS GRADING SUPERVISION PLRCTESTINQ ENVIRONMENTAL INVESTIGATIONS Wet Angle of Apparent Sample Soil Sample Density Int. Fric. Cohesion Location Type Condition (Yw- cf ) (0-Deg.) c- s fill mixture ' 1 remolded 116.7 26 368 indicates that the test was performed during the coarse of grading operations. 4. Expansion Index Test: Four expansion index tests were performed on representative onsite soil samples in accordance with the Uniform Building Code Standard 18 -2. The test results are presented in Table 5. VIN1E B MIDDLEfON ENGINEERINQ, INC. 2450 Vineyard Avenue, #101, Escrosdidu, Culifamia 92029,1229 • Aw. (760) 743.1214 • F" (760) 739 -0343 GEOTECHNICAL INVLTIGATIONS GRADING SUPERVISION PLRCTESTINQ ENVIRONMENTAL INVESTIGATIONS Mr. Zach Abbasi May 24, 1999 Page 4 TABLE 5 Sample Location Soil Type Remolded w °/a Saturation % Saturated w % Expansion Index (El) Expansion Potential fill(mixture)" 1 14.3 50.7 34.8 137 very high fill (mixture)` 1 10.1 49.2 28.2 117 high B -1 @ 5' 2 14.3 49.7 29.5 105 high B -2 3' 2 14.5 49.1 29.9 142 very high ` indicates that the test was performed during the coarse of grading operations. (w) = moisture content in percent 5. Unconfined Compression Test: Unconfined compression tests were performed on representative remolded and undisturbed samples of onsite clayey soils in accordance with the ASTM D- 2166 -91. The test results are presented in Table 6. TABLE 6 6. Grain Size Analysis: Grain size analysis were performed on representative samples of onsite soils. The test results are graphically depicted on the attached Plates 3 and 4. 7. Liquid Limit Plastic Limit and Plasticity Index: Liquid limit, plastic limit and plasticity index tests were performed on representative onsite soil samples in accordance with the ASTM D- 4318 -84. The test results are presented in Table 7. VINJE B MIDDLETON ENGINEERING INC. 2450 Vineyard Avenue, #102, Escondido, California 92029.1229 • Phone (760) 743 -1214 • Fax (760) 739 -0343 QEOTECHNICAL INT12STIQATIONS GRADING SUPERVISION PERC TESTING EM9RONXIENTAL INVIiSTICATIONS Unconfined Sample Soil Sample Axial Strain Corrected Compressive Location Type Condition Load (lbs ) (intin) Area (sq.in) Stren th TSF B -1 @ 5' 2 in -situ 170 0.050 4.18 2.93 B -2 CcD 9' 3 remolded 150 0.025 4.08 2.65 6. Grain Size Analysis: Grain size analysis were performed on representative samples of onsite soils. The test results are graphically depicted on the attached Plates 3 and 4. 7. Liquid Limit Plastic Limit and Plasticity Index: Liquid limit, plastic limit and plasticity index tests were performed on representative onsite soil samples in accordance with the ASTM D- 4318 -84. The test results are presented in Table 7. VINJE B MIDDLETON ENGINEERING INC. 2450 Vineyard Avenue, #102, Escondido, California 92029.1229 • Phone (760) 743 -1214 • Fax (760) 739 -0343 QEOTECHNICAL INT12STIQATIONS GRADING SUPERVISION PERC TESTING EM9RONXIENTAL INVIiSTICATIONS Mr. Zach Abbasi May 24, 1999 Page 5 lir-A 3MMA Location Soil Type Liquid Limit % Plastic Limit % Plasticity Index PI B -1 @ 5' 2 50 22 28 B -2 @ 3' 2 44 18 26 B -2 @ 9' 3 47 15 32 III. CONCLUSIONS AND RECOMMENDATIONS Based upon the foregoing study, posttensioned slab -on- ground foundation is feasible for the support of the proposed building. The foundation design should consider slabs with stiffening beams (ribbed foundation). In the case of uniform slab thickness foundation, the design shall satisfy all requirements of the design procedure for ribbed foundation. The fully conformant ribbed foundation is then converted to an equivalent uniform thickness foundation. In their case, however, a perimeter edge beam shall be required as specified in the following sections. The following geotechnical factors and soil design parameters are appropriate and should be considered in the final foundation design and implemented during the construction phase: Posttensioned slab -on- ground foundation design should be completed by the project design -build contractor and /or structural engineer based on the parameters provided in the following sections. All designs shall conform to the latest addition of the Uniform Building Code (UBC), specifications of the Posttensioning Institute (PTI), local standards, and the specifications given in this report. 2. Foundation bearing soil should be inspected and tested as necessary prior to trenching and actual construction by the project soils engineer. The required foundation bearing soil moisture contents within the upper 30 inches are 3% to 8% above the optimum levels within 72 hours prior to the foundation pour. In the event specified foundation soil moisture contents are not present, some earthwork efforts including ground preparations, moisture re- conditioning and recompaction of the upper 30 inches of the building areas plus 10 feet, may be necessary and should be anticipated. VIN1E ® MIDDLETON ENGINEERINQ, INC. 2450 Vinn d Avenue, 1102, Escm�dul°, Cuflforniu 92029-1229 • Plwne (760) 743.1214 • F= (760) 739.0343 GEOTECNNICAL I\V=RIATIONS gRADINq SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Mr. Zach Abbasi May 24, 1999 Page 6 A pre- saturation option is also available which will primarily depend on in -place densities of foundation bearing soil and presence of desiccation cracks on the building pad surface at the time of construction. Appropriate recommendations should be given by the project soils engineer at the time of the foundation bearing soil inspection based on actual preconstruction subgrade soil conditions. 3. A minimum of 4 inches of 3/a -inch gravel should be placed over the approved subgrade soils. In the case of pre- saturation, flood with water to the top with 3/8- inch gravel and allow the subgrade to soak. A typical soaking period for "very highly' expansive clays is 72 hours. Chemical additives may be used to reduce the soaking period provided the additives do not chemically react with the clay minerals changing soil composition, and also adversely impact in -place soil moisture - density characteristics. The required moisture contents should be confirmed within the foundation bearing soil with appropriate field testing. Upon the approval of the subgrade soils by the project geotechnical engineer, place a ten -mil plastic moisture barrier over the 3/8- inch gravel and place 2 inches of clean sand (SEz30) over the plastic. If the event the required moisture contents are present within the subgrade soils at the time of construction and pre- saturation is not necessary, the posttensioned slab underlay may consist of a minimum of four inches of clean sand (SE 30 or greater) which is provided with a six -mil plastic moisture barrier placed mid - height in the sand. 4. At the completion of ground and subgrade preparations as specified, and approval from the project soils engineer, the posttensioned slab -on- ground foundation should be constructed as detailed on the structural /construction drawings. In the case of pre- saturation, subgrade preparations and trenching for the perimeter and interior beams may be completed in any construction sequence provided all geotechnical engineering requirements are met and the work is completed in a neat, clean and orderly manner to the satisfaction of the project soils engineer. 5. Based upon our laboratory testing and analysis of the test results, the following soil design parameters may be considered. • Design predominant clay mineral type .................. Montmorillonite • Design percent of clay in soil ... ............................... 30% • Design effective plasticity index .. ............................... 23 • Design depth to constant soil suction ........................... 7 feet • Design constant soil suction ... ............................... Pf 3.6 • Design velocity of moisture flow ...................... 0.70 inch /month VINJE B MIDDLETON ENGINEEIiINQ, INC. 2450 Vinrya d Avm.e. #102, &,.,didn, Califmr iu 92029.1229 • 1'hanc (760) 743.1214 • Fax (760) 739 -0343 QEOTECHNICAL MTESTIQATIOM gRADINOSIIPLRVISION PLRC TESTINq ENVIRONMENTAL INVESTIQATIONS Mr. Zach Abbasi May 24, 1999 Page 7 • Design edge moisture variation distance for edge lift (em) ......... 3.0 feet • Design edge moisture variation distance for center lift (em) ........ 6.0 feet • Design differential swell occurring at the perimeter of slab for edge lift condition (Ym) .............................. 0.466 inches • Design differential swell occurring at the perimeter of slab for center lift condition (Ym) ............................. 3.165 inches • Design soil subgrade modulus (k) ............................. 50 pci • Design allowable foundation bearing pressure ................. 1000 psf • Design soil wet density .... ............................... 116.7 pcf • Design soil angle of internal friction ....................... 26 degrees • Design active soil pressure (level backfil1) .................. 46 pcf (EFP) • Design at -rest soil pressure ..... I ...................... 66 pcf (EFP) • Design passive soil resistance (level at the toe) ............ 298 pcf (EFP) • Design coefficient of friction (between concrete and soil) ............. 0.31 Notes: When combining passive pressure and frictional resistance, the passive component should be reduced by one - third. The allowable foundation pressures provided herein apply to dead plus live loads and may be increased by one -third for wind and seismic loading. 6. Posttensioned slab -on- ground should be a minimum of 5 inches thick and provided with a minimum of 15 inches wide by 30 inches deep edge beams. Perimeter edge beams should enclose the entire building and reinforced with 245 continuous bars top and bottom. Adequate interior stiffening ribs should also be provided as necessary. Interior ribs should be at least 12 inches wide and 18 inches deep. All depths are measured from the lowest adjacent ground level, not including the sand /gravel underlay beneath the slab. 7. We recommend considering pre- tensioning in order to preclude early concrete shrinkage cracking. IV. GENERAL RECOMMENDATIONS 1. The minimum foundation design and steel reinforcement provided herein, is based on soil characteristics only and is not intended to be in lieu of reinforcement necessary for structural considerations. All recommendations and design parameters should be further evaluated and confirmed by the project design -build contractor and /or structural engineer. VINJE B MIDDLETON ENCi1NEEIiINQ, INC. 2450 Vineyard AV .. #102, &cmtdulo, Cap(amia 92029.1229 • Phone (760) 7431214 • Fax (760) 739-0343 CILOTCC'HNICAL INNESTIQATIONS GRA M; SUPLRVISION PERC TESIINQ ENVIRONMENTAL INVESTIGATIONS Mr. Zach Abbasi May 24, 1999 Page 8 2. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or 1/3 of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. This requirement applies to all improvements and structures including fences, posts, pools, spas, etc. Concrete and AC improvements should be provided with a thickened edge to satisfy this requirement. 3. Expansive clayey soil should not be used for backfilling of any retaining structure. All retaining walls should be provided with a 1:1 wedge of granular, compacted backfill measured from the base of the wall footing to the finish surface. Retaining walls should be provided with a back drainage in general accordance with the attached Plate 5. 4. All underground utility trenches should be mechanically compacted to a minimum of 90% of the maximum dry density of the soil unless otherwise specified by the . respective agencies. Care should be taken not to crush the utilities or pipes during the compaction of the soil. 5. Site drainage over the finish pad surface should flow away from structures onto the street in a positive manner. Care should be taken during the construction, improvement, and fine grading phases, not to disrupt the designed drainage patterns. Area drains should be installed. Rooflines of the buildings should be provided with roof gutters. Roof water should be collected and directed away from the building and structures to a suitable location. Consideration should be given by the project architect to adequately damp proof /waterproof the basement walls /foundations and provide the planter areas adjacent to the foundations with an impermeable liner and a subdrainage system. Deep rooted and large trees should not be planted near the building and the associated structures. 6. Final foundation plans and construction details should reflect preliminary recommendations given in this report and should be reviewed by this office prior to actual construction. More specific recommendations should be provided when final drawings are available. 7. All foundation trenches should be inspected to assure an adequate footing embedment and confirm competent bearing soil. Foundation and slab reinforcements should also be inspected and approved by the project geotechnical consultant. VINIE B MIDDLETON ENC/INEERINCI, INC. 2450 %ry n rd Avenue, 0102, Exondldo, Califmnia 92029.1229 • Phmm (760) 743.1214 • Fax (760) 739 -0343 QCOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTIM; EWMONMENTAL INVESTIGATIONS Mr. Zach Abbasi May 24, 1999 Page 9 V. LIMITATIONS The conclusions and recommendations provided herein have been based on all available data obtained from site grading observations, research and review of pertinent geotechnical reports and plans, subsurface exploratory excavations and laboratory testing, as well as our experience with the soil and formational materials located in the general area. The materials encountered on the project site and utilized in laboratory testing are believed representative of the total area; however, earth materials may vary in characteristics between excavations. Of necessity we must assume a certain degree of continuity between exploratory excavations and /or natural exposures. It is necessary, therefore, that all observations, conclusions, and recommendations be verified during the grading operation. In the event discrepancies are noted, we should be contacted immediately so that an inspection can be made and additional recommendations issued if required. The recommendations made in this report are applicable to the site at the time this report was prepared. It is the responsibility of the owner /developer to ensure that these recommendations are carried out in the field. It is almost impossible to predict with certainty the future performance of a property. The future behavior of the site is also dependent on numerous unpredictable variables, such as earthquakes, rainfall, and onsite drainage patterns. The firm of VINJE & MIDDLETON ENGINEERING, INC. shall not be held responsible for changes to the physical conditions of the property such as addition of fill soils, added cut slopes, or changing drainage patterns which occur without our inspection or control. The property owner(s) should be aware of the development of cracks in all concrete surfaces such as floor slabs and exterior stucco associated with normal concrete shrinkage during the curing process. These features depend chiefly upon the condition of concrete and weather conditions at the time of construction and do not reflect detrimental ground movement. Hairline stucco cracks will often develop at window /door corners, and floor surface cracks up to IA -inch wide in 20 feet may develop as a result of normal concrete shrinkage (according to the American Concrete Institute). This report should be considered valid for a period of one year and is subject to review by our firm following that time. If significant modifications are made to your tentative development plan, especially with respect to the height and location of cut and fill slopes, this report must be presented to us for review and possible revision. VIN1E B MIUOLETON ENQINEERINQ, INC. 2450 Vineyard Avenue, #101, Escondido, CaUr is 920291219 • Phone(760)743-12J4 • F=(760)739.0343 IjLO7ECHNICAL IW=1QATI0NS GRA INCA SUPERVISION PERC TES7IN4 ENVIRONMENTAL INVLS17QA710NS Mr. Zach Abbasi May 24, 1999 Page 10 Vinje & Middleton Engineering, Inc. warrants that this report has been prepared within the limits prescribed by our client with the usual thoroughness and competence of the engineering profession. No other warranty or representation, either expressed or implied, is included or intended. Once again, should any questions arise concerning this report, please do not hesitate to contact this office. Reference to our Job #98 -373 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. 8,63 fnf� VINJE & IWDL &ON ENGINEEf21 J, GF CA;1E f; R M. Vinje GE #863 1 _ 1 MeHdi t RCE #46174 �� S, °G,�f ~�' • f1,,.46174 RMV /MS /jt * E\F.12 -31 -02 s. CN1l Q Distribution: Addressee (5) ���OFuv\F c: Yt \wpdocsVmisc\98- 373 -f. pt 1 VIN1E B MIDDLETON ENQINEERI.NQ, INC. 2450 Vineyard Avenue, #102, Ese adidu, Cafifmnia 92029 -1229 • Phone (760) 7434214 • Fax (760) 739.0343 QI:OTECNNICAL INVESTIGATIONS GRADIKSOPERVISION PERC TESTING EM9RONAIENTAL INVESTIGATIONS WON-BEE 4% M0091p LIEU@ nM 0 `f+ C. LEGEND B -Z & APPROX. BORING LOCATION TFILL SLOPE f CUT SLOPE JOB #98 -373 -F PLATE 1 Date: 5 -7 -99 Logged by: DM B -1 USCS FIELD FIELD DRY RELATIVE DEPTH IN SAMPLE SYMBOL MOISTURE (•/.) DENSITY (Pcf) COMPACTION N DESCRIPTION 0 - FILL: - Olive to brown silty clay to clayey silt, moist. Tight. MG /CH 20.4 102.2 91.8 2- O■ 4- 9112 - O■ 6 - 11113 FORMATIONAL: 8- Tan clayey siltstone, firm to very hard, moist. MH 14.3 117.6 -10- O■ FORMATIONAL: CH 17.2 108.0 95.4 10112 1 Pale brown claystone, very hard to hard. Moist. -12- -14- -14- 20.9 105.8 93.4 O■ - 16 15.8 113.4 LL10117 59/fi End Boring at 16'. i I Date: 5 -7 -99 Logged by: DM B -2 USCS FIELD FIELD DRY RELATIVE DEPTH (ft) SAMPLE SYMBOL MOISTURE ( %) DENSITY (Pcf) COMPACTION I% DESCRIPTION 0 - FILL: - Olive brown silty clay to clayey silt, moist. Tight. MH /CH 19.1 101.0 90.7 2- O■ 9112 4 6 - FORMATIONAL: Tan clayey siltstone, firm to very hard, moist. MH 14.3 117.6 8- O■ 37150 10- -12- -14- - - O■ 15.8 113.4 59/fi -16 - - End Boring at 16'. VINJE & MIDDLETON ENGINEERING, INC BORING LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 REMAINDER PARCEL Office 760- 743 -1214 Fax 760 - 739 -0343 PROJECT NO. 98 -373 -F PLATE 2 ♦ Sand Cone Test ■ Bulk Sample ❑ Chunk Sample 0 Driven Rings SPT ■■ ■11111■ �� ill��. ��II ■■■ ■11111 ■�■HOME ■i1111 %1 MINE ■11111■■■ t■■ ■11111■■■ ■11111■■ ■■11111■. ■11111■ ■� nl■■■■11111■■■� ■■■ ■11111■.■ ■III 1■■ ►11111■■■ ■11111 ■.IS ■■■■ 11111■■■■ 11101■■■ ■11111 ■ ■11111 ■ ■ ■■ , ■■■ ■11111■■■ ■11111■ IMIM ■11111■ ■ ■ !]I ■ ■■ ■11111■ ■ ■� ■■■ ■11111■■■ ■11111. 111■■■ IN ■■■ ■11111■■■ ■11111■ ■ ■1111■ ■■ �i,'1 ■■ ■11111 ■..■ ■ ■■ ■11111■ ■■ ■VIII■.. ■11111..■ 1 1 . VIII■ ■ , ■.. ■VIII... ■11111 ■.. ■VIII.. ■1 IC CG�� 1111. ■.� ■. ■VIII... ■11111■ . ■11111■ ■11110 11111 ■■�7�1111■ ■■ , ■ ■■ ■11111 ■.. ■VIII ■ ■■ ■11111. ■■ ■11111. ■■ �11� ■ ■■ ■■■ ■11111■■. ■1111... ■1111... 11111■■.�.� ■■ , ■■■■ 11111■■■■ 1111■ ■■ ■1111■■ ■11111■ ■ ■ ■l0�llr��� ■■■■VIII■■■ VIII ■■■■IIIII■■■■111 NINE ■■IIIII■i�� _� , ■■■ ■11111■■■m11111■ ■■1 HIM ■■ 1111■■III■■ ■ ■■■■III 1■■■ ■11 I ■ ■11 11■■ ■■■ ■ " ■.. ■111 ■.. ■1111 .■■ 11■ ■111 MINE ■11 .IN ■ ■ ■■ 11111 ■ ■■ ■11101. ■■ ■1111111■ ■■ ■VIII■.■ ■VI MEN ■ ., , ■.. ■11111 ■.. ■111 1 ■ ■■ ■11111... ■11111 ■ ■■ ■11111 ■..■ „ PLATE 3 VINJE & MIDDLETON ENGINEERING, INC. Job #99 -390 -F June 15, 2000 RMCI Development, Tres Vistas Estates Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 Phone(760)743.1214 Fax (760) 739 -0343 COMPACTION TEST RESULTS, UNDERGROUND UTILITY TRENCH BACKFILLS, FOR CALLE TRES VISTAS, DOUBLE LL RANCH ROAD AND DRIVEWAYS FOR PARCELS #1 THROUGH #4. TRES VISTAS ESTATES DOUBLE LL RANCH ROAD OLIVENHAIN In accordance with the Grading Ordinance for the City of Encinitas, this compaction report for utility trench backfills has been prepared for the above referenced site. We have completed engineering observation and testing services in conjunction with the backfill operations. This report summarizes the results of our tests and observations of the compacted backfills conducted periodically from December 30, 1999 through February 2, 2000. Actual dates are shown on the enclosed compaction test result sheets. A laboratory compaction test for each soil type was performed to determine the maximum dry density and optimum moisture in accordance with ASTM D- 1557 -91. Field density tests were performed in accordance with ASTM Method D- 1556 -90 sand cone method as the backfills were placed. The moisture content for each density sample was also determined. The results of these tests are shown on the attached sheets. The locations of the tests were so placed to provide the best possible coverage. Areas of low compaction, as indicated by the field density tests, were brought to the attention of the contractor. These areas were reworked by the contractor and retested. The test locations and final test results are summarized on the compaction test result table. The results of our field density tests and laboratory testing indicate that the utility trench backfills at the areas tested were compacted to at least 90% of the corresponding maximum dry density at the tested locations. Our description of the backfill operations, as well as observations and testing services herein, have been limited to those backfill operations performed periodically from December 30, 1999 through February 2, 2000. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain LABORATORY COMPACTION TEST RESULTS: Soil Type 1: Dark to Olive Brown Sandy Silty Clay" Maximum Dry Density: 113.2 pcf Optimum Moisture: 15.5% Soil Type 2: Olive Grey to Green Claystone" Maximum Dry Density: 111.3 pcf Optimum Moisture: 17.8% Soil Type 5: Pale Olive to Tan Sandy Silt With Clay Maximum Dry Density: 118.2 pcf Optimum Moisture: 15.5% Soil Type 6: Tan Sandy Clayey Silt Maximum Dry Density: 117.7 pcf Optimum Moisture: 14.8% Soil Type 7: Tan Fine Silty Sand With Trace Clay Maximum Dry Density: 111.7 pcf Optimum Moisture: 17.2% Soil Type 10: Brown Clayey Silty Sand Maximum Dry Density: 113.6 pcf Optimum Moisture: 17.0% Soil Type 11: Greenish Grey Silty Sand (Import) Maximum Dry Density: 137.0 pcf Optimum Moisture: 8.0% Soil Type 12: Reddish Brown Silty Sand (Import) Maximum Dry Density: 130.3 pcf Optimum Moisture: 9.6% Soil Type 13: Orange -Tan Silty Sand (Import) Maximum Dry Density: 127.6 pcf Optimum Moisture: 9.4% mpr%und rgrnd\99.3904.p1I VINIE B MIDDLETON ENGINEERING, INC. 2450 Vinyard Arnue, 0102, Escondido, Cahfmnia 92029 -1229 • Phone (760) 7434214 a F=(760)739-0343 QEOTECHNICAL LWESTIQATIONS GRADING SUPERVISION PERC TESTINQ ENVIRONMENTAL INVESTIGATIONS Underground Utility Trench Backfill Compaction Report RMCI Development, Tres Vistas Estates June 15, 2000 Page 2 If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. Ralph M. Vinje GE #863 OF RMV /fr Distribution: Addressee (6) mprWndrgrrKR99- 39Gfi.ug 1 VIN1E B MIDDLETON ENCGINEERINQ, INC. 2450 Vin-yard Avenue, 1102, Escondido, California 92029.1229 • Phone (760) 743-1214 • Fax (760) 739-0343 QEOTECHNICAL INVESTIQATIONS GRADING SUPERVISION PERE TESTINQ ENVIRONMENTAL I,NVESTIQATIONS JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Underground Trench Backfill Date 1999 Test No. Location Ht Of Fill In Ft. % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 12/30 1 Water Main, Calle Tres Vistas Sta: 2 +75 -2 8.8 124.4 137.0 90.8 Sand 12/31 2 Water Main, Calle Tres Vistas Sta: 3 +85 -2 7.5 132.9 137.0 97.0 Sand 12/31 3 Sewer Main, Calle Tres Vistas Sta: 0 +42 -1.5 198 95.0 113.2 83.9 Failed 12/31 4 Fire Hydrant Lat., Calle Tres Vistas Sta 3 +93 -4 9.1 126.7 137.0 92.5 Sand Bedding 12/31 5 Water Main Lat., To Parcel B, Sta: 4 +31 -4 8.8 126.4 137.0 92.3 Sand Bedding 2000 01/03 6 Water Main, Calle Tres Vistas Sta: 1 +50 -1.5 21.2 98.3 111.3 88.3 Failed 01/04 7 Water Main, Calle Tres Vistas Sta: 4 +00 -3 8.5 126.4 137.0 92.3 Sand 01 /06 8 Water Main, Calle Tres Vistas Sta: 1 +40 -1.5 166 108.7 111.3 97.7 Retest #6 01/18 9 Water Main, Calle Tres Vistas Sta: 4 +09 -1 18.6 89.9 111.3 80.8 Failed 01/18 10 Sewer Main, Calle Tres Vistas Sta: 4 +11 -1 21.9 104.3 111.3 93.7 01/18 11 Sewer Main, Calle Tres Vistas Sta: 0 +45 -1 15.5 102.3 113.2 90.4 Retest #3 01/18 12 Water Main, Calle Tres Vistas Sta: 3 +25 -1 16.8 100.8 111.3 90.6 01/19 13 Sewer Main, Calle Tres Vistas Sta: 4 +16 -1 15.7 113.4 118.2 95.9 Repair 01/19 14 Fire Hydrant Lat., Calle Tres Vistas Sta 3 +93 -1 16.1 103.5 113.2 91.4 01/19 15 Water Main, Calle Tres Vistas, Sta: 0 +40 -3 9.1 130.9 137.0 95.5 Sand 01119 16 Water Main, Calle Tres Vistas, Sta: 0 +30 -1.5 8.0 125.1 137.0 91.3 01/19 17 Sewer MH #1, DBL. LL Ranch Rd. Sta: 4 +48 -1.5 8.6 124.8 137.0 91.1 01/20 18 Water & Sewer Service, Driveway, Sta: 5 +25 -4 11.2 126.3 1303 96.7 Parcel 3 01/20 19 Water & Sewer Service, Driveway, Sta: 6 +83 -3.5 9.9 116.6 130.3 89.5 Parcel 3, Failed 01/20 20 Water & Sewer Service, Driveway, Sta 6 +80 -35 92 125.7 1303 965 Parcel 3, Retest #19 PIS] :L` y NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Underground Trench Backfill Date 2000 Test No. Location Ht. Of Fill In Ft % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf % Relative Comp. Comments 01/20 21 Water & Sewer Service, Driveway, Sta: 7 +90 -1 14.9 106.7 117.7 90.7 Parcel 3 01/21 22 Water & Sewer Service, Driveway, Sta: 2 +32 -2 11.1 105.1 130.3 80.7 Parcels 3 & 4, Failed 01/21 23 Water & Sewer Service, Driveway, Sta: 3 +42 -2 8.6 118.9 130.3 91.3 Parcels 3 & 4, 01/21 24 Water & Sewer Service, Driveway, Sta: 2 +35 -2 9.8 122.5 130.3 94.0 Parcels 3 & 4, Retest #22 01/21 25 Water & Sewer Service, Driveway, Sta: 5 +80 -1 15.1 107.9 117.7 91.7 Parcel 3 01/21 26 Water & Sewer Service, Driveway, Sta: 1 +30 -2 8.0 110.8 130.3 85.0 Parcels 3 & 4, Failed 01/21 27 Water & Sewer Service, Driveway, Sta: 1 +33 -2 8.5 119.0 130.3 91.3 Parcels 3 & 4, Retest #26 01/24 28 Water Tie -In, DBL LL Ranch Rd., Sta: 4 +28 -2 8.8 130.1 137.0 94.9 North Half 01125 29 Water Tie -In, DBL LL Ranch Rd., Sta: 4 +28 -4.5 8.5 127.7 137.0 93.2 South Half 01/25 30 Water Tie -In, DBL LL Ranch Rd., Sta: 4 +28 -1.5 8.3 127.0 137.0 92.7 South Half 01126 31 Dry Utilities, Calle Tres Vistas Sta: 1 +18 -3.5 5.4 121.8 127.6 95.4 01/27 32 Dry Utility Lat., Calle Tres Vistas Sta: 2 +35 -3 5.6 118.1 127.6 92.6 01/27 33 Dry Utilities, Calle Tres Vistas Sta: 3 +55 -3.5 10.9 121.2 127.6 95.0 01/28 34 Dry Utilities, Calle Tres Vistas Sta: 2 +05 -1 14.7 103.8 113.2 91.7 01/28 35 Dry Utilities, Calle Tres Vistas Sta: 1 +22 -1 16.3 105.0 113.2 92.8 01/31 36 Dry Utilities, Calle Tres Vistas Sta: 4 +46 -2 15.7 95.0 111.7 85.0 Parcel 2, Failed 01/31 37 Dry Utilities, Driveway, Sta: 2 +80 -1.5 15.9 104.9 113.6 92.3 Parcels 3 & 4 01/31 38 Dry Utilities, Driveway, Sta: 6 +05 -1.5 14.9 106.4 117.7 90.4 Parcel 3 01/31 39 Dry Utilities, Driveway, Sta: 2 +00 -1 15.8 107.8 118.2 91.2 Parcel 2 02101 40 Dry Utilities, Driveway, Sta: 0 +93 -1.5 17.8 102.0 111.3 91.6 Parcel 1 02/01 41 Dry Utilities, Calle Tres Vistas Sta: 4 +45 -2 17.8 101.8 111 7 91.1 Parcel 2, Retest #36 JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain Field Density Tests Results: Underground Trench Backfill 'From The Preliminary Geotechnical Investigation Report, By Vinje & Middleton Eng., Inc., Dated May 27, 1997, Job #97 -145 -V DBL = Double Sta: = Station Lat. = Lateral MH = Man Hole mpr\undrg md%99- 390-f.1r 1 Ht. Field Lab Of % Dry Dry Date Test Fill In Field Density Density Relative 2000 No. Location Ft. Moisture Pcf Pcf Comp. Comments 02/01 42 Water & Sewer Service, Driveway, Sta: 2 +70 -2 15.5 106.0 111.7 94.9 Parcel 2 02102 43 Dry Utilities, Driveway, Sta: 4 +00 -2 15.1 104.3 113.2 92.1 Parcel 1 02/02 44 Dry Utilities, Calle Tres Vistas Sta: 0 +40 2 183 100.2 111.3 1 90.0 'From The Preliminary Geotechnical Investigation Report, By Vinje & Middleton Eng., Inc., Dated May 27, 1997, Job #97 -145 -V DBL = Double Sta: = Station Lat. = Lateral MH = Man Hole mpr\undrg md%99- 390-f.1r 1 VINJE & MIDDLETON ENGINEERING, INC. Job #99 -390 -F June 15, 2000 RMCI Development, Tres Vistas Estates Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, #102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax (760) 739 -0343 KEYSTONE WALL SPECIAL INSPECTIONS AND BACKFILL COMPACTION TESTING, TRES VISTAS ESTATES PARCEL #2 DOUBLE LL RANCH ROAD OLIVENHAIN In accordance with the Grading Ordinance for the City of Encinitas, This compaction report for the backfill of the Keystone retaining wall has been prepared for the above referenced site. We have completed engineering observation and testing services in conjunction with the backfill operations. This report summarizes the results of our tests and observations of the placement of "Keystone Units ", "geogrid ", "wall pins ", and the compacted wall backfill conducted during the period of March 23, 2000 through March 29, 2000. Actual dates are shown on the enclosed compaction test result sheet. A laboratory compaction test for each soil type was performed to determine the maximum dry density and optimum moisture in accordance with ASTM D- 1557 -91. Field density tests were performed in accordance with ASTM D- 1556 -90 sand -cone method as backfill soils were placed. The moisture content for each density sample was also determined. The results of these tests are shown on the attached sheet. The locations of the tests were so placed to provide the best possible coverage. Areas of low compaction, as indicated by the field density tests, were brought to the attention of the contractor. These areas were reworked by the contractor and retested. The test locations and final test results are summarized on the compaction test result table. The results of our field density tests and laboratory testing indicate that the retaining wall backfill at the areas tested were compacted to at least 90% of the maximum dry density at the tested locations. Placement of "keystone units ", "pins ", length and vertical placement of the "geogrid ", back -drain installation and base leveling pad were found to be in conformance with the provided "wall' plans. Our description of the backfill operations, as well as observations and testing services herein, have been limited to those backfill operations performed during the period of March 23, 2000 through March 29, 2000. Keystone Wall Inspections and Backfill Testing RMCI Development, Tres Vistas Estates June 15, 2000 Page 2 The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. QROFESSlp p pp�� 2 NO: gtl3 � N Ralph M. a ..p.1:31{Ii x GE #863 RMV /fr Distribution: Addressee (6) mp r\wal Is 199- 390 -f. bf 1 VIN1E E MIDDLETON ENGINEERING, INC. 2450 Vin,-yard Avenue, 0102, Escondido, Califomia 92029.1229 • Phone (760) 743.1214 • F=(760)739-0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS JOB NO: 99 -390 -F NAME: RMCI Development, Tres Vistas Estates LOCATION: Double LL Ranch Road, Olivenhain TEST RESULTS Laboratory Compaction Test Results: Soil Type 13: Non Specific Decomposed Granit ( Import) Ma>amurn Dry Density: 140.0 pcf Optimum Moisture: 6.8% Field Density Test Results: Keystone Retaining Wall Backfill Parcel #2 Date 2000 Test No. Location Ht. Of Fill In Ft. % Field Moisture Field Dry Density Pcf Lab Dry Density Pcf Relative Comp. Comments 03/23 1 Easterly End 0 7.0 132.0 140.0 94.3 Bottom of Wall 03/24 2 Center +2 5.8 134.5 140.0 96.1 03124 3 Westerly End +2.5 6.0 128.2 140.0 91.6 03/27 4 Eastery End +4 6.0 131.3 140.0 93.8 03/27 5 Center +5 5.8 134.3 140.0 95.9 03127 6 Easterly End +7 6.4 121.7 140.0 86.9 Failed 03/27 7 Easterly End +7 5.9 126.2 140.0 90.1 Retest #6 03/28 8 Westerly End +9 5.8 127.2 140.0 90.9 03/28 9 East Central +11 5.0 134.2 140.0 95.9 03/28 10 West Central +13 5.5 132.3 140.0 94.5 0328 11 Center +15 5.8 130.7 140.0 93.4 Finish Grade 03/29 12 Easter/ End +10 6.0 130.7 140.0 93.4 Finish Grade m prlwal ls199 -390-f. tr 7 VINJE & MIDDLETON ENGINEERING, INC. Job #00 -238 -F May 31, 2000 Mr. Bob Davis 2240 Encinitas Boulevard, Suite #401 Encinitas, California 92024 2450 Vineyard Avenue, #102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax (760) 739 -0343 ALit9 'Li') LINIGINEERING ES CITY OF ENCINITAS UPDATE OF COMPACTION REPORT AND FOUNDATION RECOMMENDATIONS FOR PARCEL #1, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201, LOCATED OFF DOUBLE LL RANCH ROAD In accordance with your request and the requirement set forth in a report previously prepared by this office for review after six months, this report is written to bring the foundation recommendations put forth in that report into current standards, and to discuss remedial grading that will be required prior to construction of the proposed residence. I. REFERENCES The following documents have been reviewed in order to provide this Update Report: A. "Update Preliminary Geotechnical Investigation Report and Grading Plan Review' letter prepared by this office, dated December 21, 1998, Job #97- 145 -V. B. "As- Graded Compaction Report For Parcel #1, and Associated Driveway, Tres Vistas Estates, City of Encinitas TM #97 -201, Located Off Double LL Ranch Road ", prepared by this office, dated October 11, 1999, Job #98- 373 -F. II. SITE INFORMATION Grading observations and compaction testing were conducted periodically during grading of this lot from January 7, 1999 through July 21, 1999. A final as graded compaction report with compaction results and foundation recommendations was issued as indicated above. Grading was conducted in substantial conformance with the Grading Ordinance for the City of Encinitas. All inspections and testing were conducted under the supervision of this office. In our opinion, all embankments and excavations were constructed in substantial conformance with the approved grading plan, and are acceptable for their intended use. Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 2 A site inspection was made by a representative from this office on May 30, 2000, and found the site to be visually the same with respect to pad elevation, location of, and height of cut and fill slopes. Therefore, the building pad remains substantially as reported in the subject report. It is our understanding that a single family dwelling consisting of a wood framed and stucco structure supported on shallow stiff concrete footings with slab on grade construction is planned. III. RECOMMENDATIONS A. Remedial Grading 1. Due this building pad undergoing seasonal wetting and drying, between this last winter rains and today, the upper soils are no longer suitable for the support of structures. Therefore it is recommended that the upper soils to a minimum depth of 18 inches be removed and re- compacted wherever structures are to be placed. Removals should include the structure's area plus a 5 foot perimeter where possible. It may be possible, depending on the type of equipment used, to remove 12 inches, then "ripp" the bottom of the excavation an additional 6 inches, moisture conditioned to near optimum moisture content, and compacted to a minimum of 90% of the corresponding laboratory maximum dry density. The backfill soils of the excavations should also be moisture conditioned and re- compacted as described above. Testing is to be conducted to confirm minimum compaction requirements during the removal and re- compact operations. 2. If any structures, such as retaining walls are placed at or near the "toe" of the upper ascending "stabilization" slope, additional recommendations will be required so as not to impact the slope or it's backdrain. B. Foundations, Slab On Grade The previous recommendations for lowto medium expansive soils (Expansion Index = 43) with a fill differential depth of 10 feet were put forth in our October 11, 1999 V1N)E S MIDDLETON ENQINEERING, INC. 2450 Vin,yaid Awns. #102, Escondido, California 92029.1229 • Phow (760) 743 -1214 • Fax (760) 739.0343 QEOTECHNICAL INVESTIQATIONS QRADINQSLPERVISION PERC TESTING EWIRON ENTAL IWESTIQATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 3 "A- Graded" report, are to be adhered to, and are made a part of this report. It is suggested that the foundation plans be submitted to our office for review and approval prior to construction. Foundations and Slab -on -Grade. Monolithic Pour System 1. Continuous strip foundations should be a minimum of 18 inches deep measured below the lowest adjacent ground surface not including the sand under the slab. Continuous strip foundations should have a minimum width of 15 inches for single and two story structures. Spread pad footings should be at least 24 inches by 24 inches wide and 18 inches deep, for one and two story structures. Exterior continuous footings should enclose the entire building perimeter, to include the garage entryway. Exterior isolated pad footings are not allowed unless structurally tied to the perimeter foundations in both directions using tie beams. Tie beams should be at least 12 inches wide by 12 inches deep. 2. Use four #4 reinforcing bars in all interior and exterior stud bearing wall footings. Place two bars 3 inches below the top of the footing, and the other two bars 3 inches above the bottom of the footing. The tie beams should be further reinforced using #3 ties at 12 inches on center. Reinforcement for "tied" and isolated pad footings should be designed by the project structural engineer. 3. All interior slabs must be a minimum of 5 inches in thickness reinforced with #3 reinforcing bars spaced 15 inches on center each way, placed midheight in the slab. Use 4 inches of clean sand (SE 30 or greater) beneath all slabs. A six -mil plastic moisture barrier must be placed midheight in the sand. Provide re- entrant ( ±270° corners) reinforcement for all interior slabs as generally shown on the enclosed "Isolation Joints and Re- Entrant Corner Reinforcement" detail. Re- entrant corners will depend on slab geometry and /or interior column locations. 4. The minimum steel reinforcement provided herein is based on soil characteristics only, and is not intended to be in lieu of reinforcement necessary for structural considerations. 5. The clayey soil should not be allowed to dry before pouring the concrete. The soil should be 3% to 5% above the optimum moisture content at 18 inches below slab subgrade. This office should be notified 72 hours prior to pouring the VIN1E B MIDDLETON ENGINEERING, INC. 2450 Vin,,Wrd Asmve, 0102, Escrosdido. California 92029 -1229 • Phone (760) 7434214 • 1=" (760) 739 -0343 CEOTECHNICAL IWESTIQATIONS QRADINGSUPERVISION PERC TESTINQ ENVIRONMENTAL LWESfIGAT10NS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 4 footings and slab to inspect the footing trenches and to verify the moisture conditions. 6. Provide contraction joints consisting of sawcuts spaced 10 feet on center each way within 24 hours of concrete pour for all interior slabs. The sawcuts must be a minimum of % inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. 7. All underground utility trenches under slabs should be compacted to a minimum of 90% of the maximum dry density of the soil. Care should be taken not to crush the utilities or pipes during the compaction of the trench backfill. 8. Exterior Flatwork and Driveways: a) Walkways, patios, etc. must be a minimum of 4 inches in thickness reinforced with 6x6 /10x10 welded wire mesh placed midheight in the slab. Use 4 inches clean sand (SE 30 or greater) beneath these slabs. Provide contraction joints consisting of sawcuts spaced 10 feet on center each way within 24 hours of concrete pour for all exterior slabs. The sawcuts must be a minimum of 3/4 inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. b) Concrete driveways and parking areas should consist of 5 inch thick concrete reinforced with #3 reinforcing bars spaced 18 inches on center each way placed two inches below the top of the slab. The concrete should be placed over 6 inches Cal Trans Class II aggregate base compacted to 95% over 12 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. Provide contraction joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The depths of the sawcuts should be as described in Item #a) above. c) Asphalt concrete (AC) driveways and parking areas should consist of 4 inches AC over 6 inches Cal Trans Class II aggregate base compacted to a minimum of 95% over 12 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. d) Exterior slabs placed against the perimeter footings should be doweled to the footing using #3 reinforcing bars spaced 18 inches on center, extending 20 inches into the slab at mid - height, and into the footing to the elevation of the bottom reinforcing bar. VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, 0102, Escondido, California 920294229 • Phone (760) 7434214 • Fox (760) 739-0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL IWESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 5 Unless requested, recommendations for a future swimming pool or spa were not included in this report. Prior to their construction this office should be contacted to update conditions and provide additional recommendations. 9. This office is to be notified to inspect or test the following prior to foundation concrete pours: a) Inspect the plumbing trenches beneath slabs after the pipes are laid and prior to backfilling. b) Test the plumbing trenches beneath slabs for minimum compaction requirements. c) Inspect the footing trenches for proper width, depth, reinforcing size and placement. Inspect the slabs for proper thickness, reinforcing size and placement, sand thickness and moisture barrier placement. 10. The following allowable foundation and lateral pressures maybe used for design of foundations on certified soils for structures which have continuous footings having a load of less than 2,000 plf and isolated footings with loads of less than 50,000 lbs. a) Our tests and calculations indicate that an allowable bearing capacity of 1,500 psf for continuous and isolated footings may be used. The allowable soil bearing pressure provided herein is for dead plus live loads and may be increased by one -third for wind and seismic loading. b) The allowable soil bearing pressure provided herein was determined for footings having a minimum width of 12 inches and a minimum depth of 12 inches below the lowest adjacent ground surface. This value may be increased per Uniform Building Code for additional depths only. c) An allowable lateral bearing pressure of 100 psf per foot of depth may also be used for all structures except retaining walls. The lateral bearing earth pressure may be increased by the amount of the designated value for each additional foot of depth to a maximum of 1,000 psf. VRPJE @ MIDDLETON ENQINEERINQ, INC. 2450 Vinyard Aumue, #102, Escondido, California 92029-1229 • Phone (760) 7434214 • Fax (760) 739 -0343 GEOTECHNICAL IWESTIQATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL IWESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 6 C. Retaining Walls, Lateral Load Parameters 1. The following earth pressures based on the on site mixture of soils. should be used for design of retaining any on site walls if used: a) Use a friction angle of 36 degrees. b) Use a wet density of 117.3 pcf. c) Use a coefficient of friction of 0.40 for concrete on soil. d) Use an active pressure of 31 pcf equivalent fluid pressure for cantilever, unrestrained walls with level backfill surface. e) Use a active pressure of 43 pcf equivalent fluid pressure for cantilever walls with a 2:1 (horizontal to vertical) backfill. `* f) Use an at rest pressure of 48 pcf equivalent fluid pressure for restrained walls. g) Use a passive resistance of 452 pcf equivalent fluid pressure for level surface condition at the toe. h) Use an allowable bearing capacity of 1,500 psf as described above. 2. Expansive clayey soils should not be used for backfilling of any retaining walls. Retaining walls should maintain at least a 1.1 (horizontal to vertical) wedge of granular non - expansive soil backfill measured from the base of the wall footing to the ground surface. All retaining walls should be provided with a drain along the backside as generally shown on the enclosed "Retaining Wall Drain" detail. Specific drainage provisions behind retaining wall structures must be inspected by this office prior to backfilling the wall. All backfill soils must be compacted to a minimum of 90% of the corresponding maximum dry density, ASTM 1557 -91. Note: Because large movements must take place before maximum passive resistance can be developed, use a minimum safety factor of 2.0 for wall sliding stability where structures or improvements are planned near or adjacent to the top of the wall. VIN1E B MIDDLETON ENQINEERING, INC. 1450 Vinyard Auam<, 0102, Escondido, Catift wa 92029.1229 • Phone (760) 743 -1214 • Fax (760) 739 -0343 GEOTECHNICAL INVESTIGATIONS GRAOINQ SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 7 When combining passive and frictional resistance, the passive component should be reduced by one - third. 3. The planting of large trees behind any retaining wall will adversely affect their performance and should be avoided. D. Seismic Coefficients The following site specific seismic parameters for the above referenced project were determined in accordance with the Uniform Building Code requirements. The following parameters are consistent with the indicated project seismic environment and may be utilized for project design work. According to Chapter 16. Division IV of the 1997 Uniform Building Code E. Setbacks 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. 2. The outer edge of all slopes experience "down slope creep ", which may cause distress to structures. If any structures including buildings, patios, sidewalks, swimming pools, spas etc, are placed within the setback, FURTHER RECOMMENDATIONS WILL BE REQUIRED. Expansive soils can cause structural damage to foundations. interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. VINJE B MIDDLETON ENGINEERING, INC. 2450 Vm yaid Avenue, #102, Ewmd+do, Califmnla 920294229 • Phone (760) 7434214 • I= (760) 739-0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTINQ EWIRONMENTAL INVESTIGATIONS Seismic Response Coefficients Site Soil Seismic Seismic Profile Seismic Zone Source Na Nv Ca Cv Ts To Type Zone Factor Type Sc 4 0.4 B 1.0 1.0 0.40 1 0.56 0.560 0.112 According to Chapter 16. Division IV of the 1997 Uniform Building Code E. Setbacks 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. 2. The outer edge of all slopes experience "down slope creep ", which may cause distress to structures. If any structures including buildings, patios, sidewalks, swimming pools, spas etc, are placed within the setback, FURTHER RECOMMENDATIONS WILL BE REQUIRED. Expansive soils can cause structural damage to foundations. interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. VINJE B MIDDLETON ENGINEERING, INC. 2450 Vm yaid Avenue, #102, Ewmd+do, Califmnla 920294229 • Phone (760) 7434214 • I= (760) 739-0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTINQ EWIRONMENTAL INVESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 8 " "A COPY OF THIS REPORT MUST BE PROVIDED TO THE PROJECT ARCHITECT /STRUCTURAL ENGINEER TO ENSURE THE THE ABOVE FOUNDATION RECOMMENDATIONS ARE INCLUDED IN APPROPRIATE PLANS" Expansive soils can cause structural damage to foundations, interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. The concrete reinforcement recommendations provided herein should not be considered to preclude the development of shrinkage related cracks, etc.; rather, these recommendations are intended to minimize this potential. If shrinkage cracks do develop, as is expected from concrete, reinforcements tend to limit the propagation of these features. These recommendations are believed to be reasonable and in keeping with the local standards of construction practice. Special attention should be given to any "re- entrant' corners (270 degree corners) and curing practices during and after concrete pour in order to further minimize shrinkage cracks. F. Slopes All slopes should be landscaped with types of plants and planting that do not require excessive irrigation. Excess watering of slopes should be avoided. Slopes left unplanted will be subject to erosion. The irrigation system should be installed in accordance with the governing agencies. Water should not be allowed to flow over the slopes in an uncontrolled manner. Until landscaping is fully established, plastic sheeting should be kept accessible to protect the slopes from periods of prolonged and/or heavy rainfall. Berms should be constructed along the top edges of all fill slopes Brow ditches should be constructed along the top of all cut slopes sufficient to guide runoff away from the building site and adjacent fill slopes prior to the project being completed. G. Drainage The owner /developer is responsible to insure adequate measures are taken to properly finish grade the building pad after the structures and other improvements VIN1E 9 MIDDIETON ENQINEERINQ, INC. 2450 Vin•.yard Avcva<, #102, Esem", C.Iifm is 91029.1229 • Pha (760) 743 -1214 • Fm (760) 739 -0343 QEOTECHNICA IWESTIQATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL IWESlIQATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 9 are in place so that the drainage waters from the improved site and adjacent properties are directed away from proposed structures in accordance with the designed drainage patterns shown on the approved plans. A minimum of two percent gradient should be maintained away from all foundations. Roof gutters and downspouts should be installed on the building, all discharge from downspouts should be led away from the foundations and slab to a suitable location. Installation of area drains in the yards should also be considered. Planter areas adjacent to foundations should be provided with damp /water proofing, using an impermeable liner against the footings, and a subdrainage system within the planter area. It should be noted that shallow groundwater conditions may still develop in areas where no such conditions existed prior to site development. This can be contributed to by substantial increases of surface water infiltration resulting from landscape irrigation which was not present before the development of the site. It is almost impossible to absolutely prevent the possibility of shallow groundwater on the entire site. Therefore, we recommend that shallow groundwater conditions be remedied if and when they develop. The property owner should be made aware that altering drainage patterns, landscaping, the addition of patios, planters, and other improvements, as well as over irrigation and variations in seasonal rainfall, all affect subsurface moisture conditions, which in turn affect structural performance. IV. GENERAL INFORMATION It should be noted that the characteristics of as- compacted fill may change due to post - construction changes from cycles of drying and wetting, water infiltration, applied loads, environmental changes, etc. These changes can cause detrimental changes in the fill characteristics such as in strength behavior, compressibility behavior, volume change behavior, permeability, etc. The owner /developer should be made aware of the possibility of shrinkage cracks in concrete and stucco materials. The American Concrete Institute indicates that most concrete shrinks about 1/8 -inch in 20 feet. Separation between construction and cold joints should also be expected. V1NJE B MIDDLETON ENGINEERIN(j, INC. 2450 Vin yard Avenue, 1102, Escondido, Cahfmaia 92029.1229 • Phone (760) 743 -1214 • Fax (760) 739.0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 10 The amount of shrinkage related cracks that occur in concrete slab -on- grades, flatwork and driveways depend on many factors, the most important of which is the amount of water in the concrete mix. The purpose of the slab reinforcement is to keep normal concrete shrinkage cracks closed tightly. The amount of concrete shrinkage can be minimized by reducing the amount of water in the mix. To keep shrinkage to a minimum, the following should be considered: A. Use the stiffest mix that can be handled and consolidated satisfactorily. B. Use the largest maximum size of aggregate that is practical, for example concrete made with 3/8 inch maximum size aggregate usually requires about 40 pounds (nearly 5 gallons) more water per cubic yard than concrete with 1 inch aggregate. C. Cure the concrete as long as practical. The amount of slab reinforcement provided for conventional slab -on -grade construction considers that good quality concrete materials, proportioning, craftsmanship, and control tests where appropriate and applicable are provided. This office is to be notified no later than 3 p.m. on the day before any of the following operations begin to schedule appropriate testing and /or inspections. A. Fill placed under any conditions 12 inches or more in depth, to include: 1. Building pads. 2. Street improvements, sidewalks, curbs and gutters. 3. Utility trench backfills. 4. Retaining wall backfills. 5. The spreading or placement of soil obtained from any excavation (footing or pool, etc.). B. Inspection and testing of subgrade and basegrade beneath driveways, patios, sidewalks, etc., prior to placement of pavement or concrete. C. Moisture testing. VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vinyard Avenue, 0102, Escondido, California 920294229 • Phone (760) 743.1214 • Fax (760) 739.0343 GEOTECBNICAL INVESTIGATIONS GRA Wq SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Update Compaction Report & Foundation Recommendations Parcel #1, Tres Vistas Estates May 31, 2000 Page 11 D. Foundation inspections. E. Any operation not included herein which requires our testing, observation, or inspection for certification to the appropriate agencies. laRIMM-1wigl Our description of grading operations, as well as observations and testing services herein, have been limited to those grading operations performed during the period of January 7, 1999 through July 21, 1991. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. This report should be considered valid for permit purposes for a period of six months and is subject to review by our firm following that time. IF ANY CHANGES ARE MADE -PAD SIZE, BUILDING LOCATION, ELEVATIONS, ETC. - THIS REPORT WILL BECOME INVALID AND FURTHER ENGINEERING AND RECOMMENDATIONS WILL BECOME NECESSARY. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #00 -238 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. INC. RMV /MS /mpr Distribution: Addressee (4) mprf iilk�2384.url VINIE B MIDDLETON ENGINEERING, INC. 2450 Vinyard Avenue, 0102, Escondido, California 92029.1229 • Phone (760) 743.1214 • F" (760) 739-0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS RETAINING WALL DRAIN DETAIL Typical - no scale Granular, non-exponsive bockfill. Compacted Waterproofing — Filter Material. Crushed rock (wrapped in filter fabric) or Class 2 Permeable Material Perforated drain pipe (see specifications below) Competent, approved' soils or bedrock CONSTRUCTION SPECIFICATIONS: SPECIFICATIONS FOR CALTRANS UASS 2 PERMEABLE MATERIAL 468- 1.025) t1S.STANOARO SIEVE SIZE %PASSING in 3l4 90 -100 are 40-100 No .4 2540_ No. 8 18-33 No, 30 5 -15 No, 50 0-7 No. 200 0-3 Sand Equivalent> 75 1. Provide granular, non- expansive backfill soil in 1:1 gradient wedge behind wall. Compact backfill to minimum 90% of laboratory standard. 2. Provide back drainage for wall to prevent build -up of hydrostatic pressures. Use drainage openings along base of wall or back drain system as outlined below. 3. Backdrain should consist of 4" diameter PVC pipe (Schedule 40 or equivalent) with perforations down. Drain to suitable outlet at minimum 1 %. Provide'/." - 155" crushed gravel filter wrapped in fitter fabric (Mirafi 140N or equivalent). Delete filter fabric wrap if Caltrans Class 2 permeable material is used. Compact Class 2 material to minimum 90% of laboratory standard. 4. Seal back of wall with waterproofing in accordance with architect's specifications. 5. Provide positive drainage to disallow ponding of water above wall. Lined drainage ditch to minimum 2% flow away from wall is recommended. Use 134 cubic foot per foot with granular backfill soil and 4 cubic foot per foot if expansive backfill soil is used. VINJE & MIDDLETON ENGINEERING, INC. PLATE !1 ISOLATION JOINTS AND RE- ENTRANT CORNER REINFORCEMENT (a) Typical - no scale 4TION JOINTS (b) RACTION JOINTS (C) RE-ENTRANT C( REINFORCEMEW NO. 4 BARS PL BELOW TOP OF 611 *1i ENTRANT NER CRACK 1. Isolation joints around the columns should be either circular as shown in (a) or diamond shaped as shown in (b). If no isolation joints are used around columns, or if the corners of the isolation joints do not meet the contraction joints, radial cracking as shown in (c)may occur (reference ACI). 2. In order to control cracking at the re- entrant corners ( ±270° corners), provide reinforcement as shown in (c). 3. Re- entrant comer reinforcement shown herein is provided as a general guideline only and is subject to verification and changes by the project architect and/or structural engineer based upon slab geometry, location, and other engineering and construction factors. VINJE & MIDDLETON ENGINEERING, INC. PLATE f2 VINJE & MIDDLETON ENGINEERING, INC. Job #99 -390 -F May 26, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue, *102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax (760) 739.0343 o � WZB� D OF ADDENDUM TO PREVIOUSLY ISSUED FOUNDATION RECOMMENDATIONS REPORT DATED JANUARY 17, 2000 FOR PARCEL #4, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201. LOCATED OFF DOUBLE LL RANCH ROAD Indications of adverse soil conditions after last winters rains are presently not evident on this lot. Therefore, all recommendations put forth in our January 17, 2000 "Foundation Recommendations Report" for this Parcel should be adhered to. If you have any questions or need clarification, please do not hesitate to contact this office. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON Vinje GE #863 RMV /MS /mpr Distribution: Addressee (6) mprVi11cont09>336f. Ito INC. Mehdi Shari RCE #46174 Np.46114 1 z fXP.12-3i -02 r CNW- OF VINJE F- MIDDLETON ENGINEERING, INC. Job #99 -390 -F January 17, 2000 RMCI Development Attention: Mr. Bob Mueller 514 Via De La Valle, Suite #210 Solana Beach, California 92075 2450 Vineyard Avenue,#102 Escondido, California 92029 -1229 Phone(760)743 -1214 Fax(760)739 -0343 FOUNDATION RECOMMENDATIONS FOR PARCEL #4, TRES VISTAS ESTATES, CITY OF ENCINITAS TM #97 -201 LOCATED OFF DOUBLE LL RANCH ROAD In accordance with the Grading Ordinance for the City of Encinitas, this report has been prepared for the above referenced project. We have completed engineering observation and testing services in conjunction with the grading operations. This report summarizes the results of tests undertaken in order to provide for foundation recommendations. Grading for this "cut' pad was conducted periodically from February 2, 1999, though April 5, 1999. As this is a "cut' pad, and no fills were placed, no field density testing was conducted or required I. GRADING INFORMATION /GROUND PREPARATION Grading plans for this project were prepared by Pasco Engineering. The following listed reports were reviewed by this office as part of this project: A. "Preliminary Geotechnical Investigation Proposed 5 Parcel Subdivision" report prepared by this office, dated May 27, 1998, Job #97- 145 -V. - -B. "Clarification Letter On Preliminary Geotechnical Investigation Report" prepared by this office, dated April 28, 1998, Job #97- 145 -V. C. "Response to Consultant Review of Preliminary Geotechnical Investigation, Proposed 5 Parcel Subdivision" letter prepared by this office, dated August 11, 1998, Job #97- 145 -V. D. "Updated Preliminary Geotechnical Investigation Report and Grading Plan Review" letter prepared by this office, dated December 21, 1998, Job #97- 145 -V. Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 2 Prior to grading operations, the site was cleared of vegetation Site preparation and grading were conducted in substantial conformance with the Grading Ordinance for City of Encinitas and our above listed preliminary and update geotechnical report. All inspections and testing were conducted under the observation of this office. In our opinion, all embankments and excavations were constructed in substantial conformance with the provided grading plan, and are acceptable for their intended use. A. Maximum Dry Density Optimum Moisture Tests: The maximum dry density and optimum moisture contents of the different soil types used as compacted fill were determined in accordance with ASTM Method D- 1557 -91. B. Expansion Tests: Expansion tests were conducted per 1994 UBC Standard Procedure 18 -2 on representative samples of the mixture of on site soils used in the pad construction to determine the expansion potential and to provide appropriate foundation recommendations. C. Direct Shear Tests: Direct shear tests were performed on representative samples of the mixture of on site soils used in pad construction to determine the allowable bearing capacity and to provide retaining wall design parameters. III. RECOMMENDATIONS The following minimum foundation recommendations for very expansive (Expansion Index = Less Than 20) soils, classified using the "Unified Soil Classification System or USCS" as SM, should be adhered to, incorporated into the foundation plans. It is suggested that the foundation plans be submitted to our office for review and approval prior to construction. Please note ( ") items for revised recommendations since the issuance of our original preliminary report. A. Foundations and Slab -on- Grade. Monolithic Pour System 1. Continuous strip foundations should be a minimum of 12 inches wide by 12 inches deep, and 15 inches wide by 18 inches deep for one and two story structures respectively. Spread pad footings should be at least 24 inches by 24 inches wide and 12 inches deep, for one and two story structures. Minimum depths are measured from the lowest adjacent ground surface, not ViNJE B MIDDL TON ENQINEERINC, INC. 2450 Vineyard Avenue. #102, Escondido, Califomia 92029.1229 • Phone (760) 7431114 • Far (760) 739.0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 3 including the sand under the slab. Exterior continuous footings should enclose the entire building perimeter, to include the garage entryway. 2. Use four #4 reinforcing bars in all interior and exterior stud bearing wall footings. Place two bars 3 inches below the top of the footing, and two bars 3 inches above the bottom of the footing. Reinforcement for isolated square footings should be designed by the project structural engineer. 3. All interior slabs must be a minimum of 4 inches in thickness reinforced with #3 reinforcing bars spaced 18 inches on center each way, placed midheight in the slab. Use 4 inches of clean sand (SE 30 or greater) beneath all slabs. A six -mil plastic moisture barrier must be placed midheight in the sand. Provide re- entrant (±2700 corners) reinforcement for all interior slabs as generally shown on the enclosed "Isolation Joints and Re- Entrant Corner Reinforcement' detail. Re- entrant corners will depend on slab geometry and /or interior column locations. 4. The minimum steel reinforcement provided herein is based on soil characteristics only, and is not intended to be in lieu of reinforcement necessary for structural considerations. 5. Provide contraction joints consisting of sawcuts spaced 10 feet on center each way within 24 hours of concrete pour for all interior slabs. The sawcuts must be a minimum of 1/4 inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. 6. All underground utility trenches beneath interior and exterior slabs should be compacted to a minimum of 90% of the maximum dry density of the soil. Care should be taken not to crush the utilities or pipes during the compaction of the trench backfill. 7. Exterior Flatwork and Driveways: a) Walkways, patios, etc. must be a minimum of 4 inches in thickness reinforced with 6x6 /10x10 welded wire mesh carefully placed two inches below the top of the slab. Provide contraction joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The sawcuts must be a minimum of % inch in depth and must not exceed 1'/4 inch in depth or the reinforcing may be damaged. VIN3E B MIDDIE'TON ENGINEERING, INC. 1450 Vineyard Avenue, 0102, Escondido, Cadfmnia 92029 -1129 • Phmm (760) 7431214 • Pax (760) 739.0343 GEOTLCHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 4 b) Concrete driveways and parking areas should consist of 5 inch thick concrete reinforced with #3 reinforcing bars spaced 18 inches on center each way placed two inches below the top of the slab. The concrete should be placed over 6 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. Provide contraction joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The depths of the sawcuts should be as described in Item #a) above. c) Asphalt concrete (AC) driveways and parking areas should consist of 3 inches AC over 6 inches Cal Trans Class 11 aggregate base compacted to a minimum of 95% over 6 inches subgrade compacted to a minimum of 95% of ASTM 1557 -91. Unless requested, recommendations for a future swimming pool or spa were not included in this report. Prior to their construction this office should be contacted to update conditions and provide additional recommendations. 8. This office is to be notified to inspect or test the following prior to foundation concrete pours: a) Inspect the plumbing trenches beneath slabs after the pipes are laid and prior to backfilling. b) Test the plumbing trenches beneath slabs for minimum compaction requirements. c) Inspect the footing trenches for proper width, depth, reinforcing size and placement. Inspect the slabs for proper thickness, reinforcing size and placement, sand thickness and moisture barrier placement. 9. The following allowable foundation and lateral pressures may be used for design of foundations on certified soils for structures which have continuous footings having a load of less than 2,000 plf and isolated footings with loads of less than 50,000 lbs. a) Our tests and calculations indicate that an allowable bearing capacity of 2,000 psf for continuous and isolated footings may be used. The allowable soil bearing pressure provided herein is for dead plus live loads and may be increased by one -third for wind and seismic loading. VIN1E B MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, 0102, Escondido, California 920291219 • Phm e¢ (760) 7431214 • I= (760) 739-0343 CEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PE.RC TEMNG ENVIRONMENTAL INVEST /CATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 5 b) The allowable soil bearing pressure provided herein was determined for footings having a minimum width of 12 inches and a minimum depth of 12 inches below the lowest adjacent ground surface. This value may be increased per Uniform Building Code for additional width and depth if needed. c) An allowable lateral bearing pressure of 150 psf per foot of depth may also be used for all structures except retaining walls. The lateral bearing earth pressure may be increased by the amount of the designated value for each additional foot of depth to a maximum of 1,500 psf. B. Retaining Walls, Lateral Load Parameters 1. The following earth pressures based on the finish grade very low expansive "cut" soils, should be used for design of retaining walls: a) Use a friction angle of 38 degrees. b) Use a wet density of 118 pcf. c) Use a coefficient of friction of 0.40 for concrete on soil. d) Use an active pressure of 29 pcf equivalent fluid pressure for cantilever, unrestrained walls with level backfill surface. e) Use a active pressure of 42 pcf equivalent fluid pressure for cantilever walls with a 2:1 (horizontal to vertical) backfill. f) Use an at rest pressure of 46 pcf equivalent fluid pressure for restrained walls. g) Use a passive resistance of 400 pcf equivalent fluid pressure for level surface condition at the toe. h) Use an allowable bearing capacity of 2,000 psf as described above. 2. Expansive clayey soils should not be used for backfilling of any retaining walls. Retaining walls should maintain at least a 1:1 (horizontal to vertical) wedge of granular non - expansive soil backfill measured from the base of the wall footing VINJE B MIDDIFTON ENQINEERINQ, INC. 1450 Vineyard Avenue, 1101, Escondido, California 920191219 • Phone (760) 7431214 • Far (760) 739 -0343 C,EOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING EWRONMH- AL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 5 to the ground surface. All retaining walls should be provided with a drain along the backside as generally shown on the enclosed "Retaining Wall Drain" detail. Specific drainage provisions behind retaining wall structures must be inspected by this office prior to backfilling the wall. All backfill soils must be compacted to a minimum of 90% of the corresponding maximum dry density, ASTM 1557 -91. Note: Because large movements must take place before maximum passive resistance can be developed, use a minimum safety factor of 2.0 for wall sliding stability where structures or improvements are planned near or adjacent to the top of the wall. When combining passive and frictional resistance, the passive component should be reduced by one - third. 3. The planting of large trees behind any retaining wall will adversely affect their performance and should be avoided. C. Seismic Coefficients The following site specific seismic parameters for the above referenced project were determined in accordance with the Uniform Building Code requirements. The following parameters are consistent with the indicated project seismic environment and may be utilized for project design work. According to Chapter 16, Division IV of the 1997 Uniform Building Code 911.0 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. VIN1E N MIDDLETON ENQINEERINQ, INC. 2450 Vineyard Avenue, 0102, Escondido, Ca4fomia 92029.1229 • Phmu (760) 743-1114 • F"(760)739-0343 GEOTECHNICAL INVESTIGATION QRA INQ SLIPERVLSION PERC TESTING EN47RONMENTAL INVESIGATIOM Seismic Response Coefficients Site Soil Seismic Seismic Profile Type Seismic Zone Zone Factor Source Type Na Nv Ca Cv Ts To Sc 4 0.4 B 1.0 1.0 0.40 0.56 0.560 0.112 According to Chapter 16, Division IV of the 1997 Uniform Building Code 911.0 1. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. VIN1E N MIDDLETON ENQINEERINQ, INC. 2450 Vineyard Avenue, 0102, Escondido, Ca4fomia 92029.1229 • Phmu (760) 743-1114 • F"(760)739-0343 GEOTECHNICAL INVESTIGATION QRA INQ SLIPERVLSION PERC TESTING EN47RONMENTAL INVESIGATIOM Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 7 2. The outer edge of all slopes experience "down slope creep ", which may cause distress to structures. If any structures including buildings, patios, sidewalks, swimming pools, spas etc, are placed within the setback, FURTHER RECOMMENDATIONS WILL BE REQUIRED. Expansive soils can cause structural damage to foundations, interior and exterior slabs and walls. The economically feasible precautions that can be taken and recommended herein will only minimize the potential of volumetric changes due to changes in moisture content. * *A COPY OF THIS REPORT MUST BE PROVIDED TO THE PROJECT ARCHITECT /STRUCTURAL ENGINEER TO ENSURE THE THE ABOVE FOUNDATION RECOMMENDATIONS ARE INCLUDED IN APPROPRIATE PLANS`* The concrete reinforcement recommendations provided herein should not be considered to preclude the development of shrinkage related cracks, etc., rather, these recommendations are intended to minimize this potential. If shrinkage cracks do develop, as is expected from concrete, reinforcements tend to limit the propagation of these features. These recommendations are believed to be reasonable and in keeping with the local standards of construction practice. Special attention should be given to any 'Ye- entrant' corners ( +270 degree corners) and curing practices during and after concrete pour in order to further minimize shrinkage cracks. E. to es All slopes should be landscaped with types of plants and planting that do not require excessive irrigation. Excess watering of slopes should be avoided. Slopes left unplanted will be subject to erosion. The irrigation system should be installed in accordance with the governing agencies. Water should not be allowed to flow over the slopes in an uncontrolled manner. Until landscaping is fully established, plastic sheeting should be kept accessible to protect the slopes from periods of prolonged and /or heavy rainfall. Berms should be constructed along the top edges of all fill slopes. In no case should water be allowed to pond or flow over slopes. VINE 9 MIDDLETON ENGINEERING, INC. 2450 Vinqurd Avenue, 1102, Califo is 92029 -1229 * Pha (760) 7431214 * I= (760) 739-0343 QEOTECHNICA INVESTIGATIONS GRA INQ SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 8 Brow ditches should be constructed along the top of all cut slopes sufficient to guide runoff away from the building site and adjacent fill slopes prior to the project being completed. F. Drainage The owner /developer is responsible to insure adequate measures are taken to properly finish grade the building pad after the structures and other improvements are in place so that the drainage waters from the improved site and adjacent properties are directed away from proposed structures in accordance with the designed drainage patterns shown on the approved plans. A minimum of two percent gradient should be maintained away from all foundations. Roof gutters and downspouts should be installed on the building, all discharge from downspouts should be led away from the foundations and slab to a suitable location. Installation of area drains in the yards should also be considered. Planter areas adjacent to foundations should be provided with damp /water proofing, using an impermeable liner against the footings, and a subdrainage system within the planter area. It should be noted that shallow groundwater conditions may still develop in areas where no such conditions existed prior to site development. This can be contributed to by substantial increases of surface water infiltration resulting from landscape irrigation which was not present before the development of the site. It is almost impossible to absolutely prevent the possibility of shallow groundwater on the entire site. Therefore, we recommend that shallow groundwater conditions be remedied if and when they develop. The property owner should be made aware that altering drainage patterns, landscaping, the addition of patios, planters, and other improvements, as well as over irrigation and variations in seasonal rainfall, all affect subsurface moisture conditions, which in turn affect structural performance. IV. GENERAL INFORMATION It should be noted that the characteristics of as- compacted fill may change due to post - construction changes from cycles of drying and wetting, water infiltration, applied loads, VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Asxmae, #102, Escondido, California 920291229 • Phone (760) 743.1214 • Fax (760) 739.0343 GEOTECHNICA INVESTIGATIONS GRADING SUPERVISION PERC TESTING EMUONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 9 environmental changes, etc. These changes can cause detrimental changes in the fill characteristics such as in strength behavior, compressibility behavior, volume change behavior, permeability, etc. The owner /developer should be made aware of the possibility of shrinkage cracks in concrete and stucco materials. The American Concrete Institute indicates that most concrete shrinks about 1/9 inch in 20 feet. Separation between construction and cold joints should also be expected The amount of shrinkage related cracks that occur in concrete slab -on- grades, flatwork and driveways depend on many factors, the most important of which is the amount of water in the concrete mix. The purpose of the slab reinforcement is to keep normal concrete shrinkage cracks closed tightly. The amount of concrete shrinkage can be minimized by reducing the amount of water in the mix. To keep shrinkage to a minimum, the following should be considered: A. Use the stiffest mix that can be handled and consolidated satisfactorily. B. Use the largest maximum size of aggregate that is practical, for example concrete made with 3/e inch maximum size aggregate usually requires about 40 pounds (nearly 5 gallons) more water per cubic yard than concrete with 1 inch aggregate. C. Cure the concrete as long as practical. The amount of slab reinforcement provided for conventional slab -on -grade construction considers that good quality concrete materials, proportioning, craftsmanship, and control tests where appropriate and applicable are provided. This office is to be notified no later than 2 p.m. on the day before any of the following operations begin to schedule appropriate testing and /or inspections. A. Fill placed under any conditions 12 inches or more in depth, to include: 1. Building pads. 2. Street improvements, sidewalks, curbs and gutters. 3. Utility trench backfills. VIN1E B MIDDLETON ENGINEERINQ, INC. 2450 Vineyard Avenue, 9101, Es,on do, CaG(ornio 92029-1229 • Phone (760) 743.1214 • Fax (760) 739.0343 GEOTECNNICAL INVESTIGATIONS GRADING SUPERVISION PERC TESTING ENVIRONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel 44, Encinitas TM #97 -201 January 17, 2000 Page 10 4. Retaining wall backfills. 5. The spreading or placement of soil obtained from any excavation (footing or pool, etc.). B. Inspection and testing of subgrade and basegrade beneath driveways, patios, sidewalks, etc., prior to placement of pavement or concrete. C. Moisture testing. D. Foundation inspections. E. Any operation not included herein which requires our testing, observation, or inspection for certification to the appropriate agencies. V. LIMITATIONS Our description of grading operations, as well as observations and testing services herein, have been limited to those grading operations performed periodically from February 2, 1999, though April 5, 1999. The conclusions contained herein have been based upon our observations and testing as noted. No representations are made as to the quality or extent of materials not observed and tested. The attached drawing details the approximate locations of cuts, fills, and locations of the density tests taken and is applicable to the site at the time this report was prepared. This report should be considered valid for permit purposes for a period of six months and is subject to review by our firm following that time. IF ANY CHANGES ARE MADE, PAD SIZE, BUILDING LOCATION, ELEVATIONS, ETC. - THIS REPORT WILL BECOME INVALID AND FURTHER ENGINEERING AND RECOMMENDATIONS WILL BECOME NECESSARY. If you have any questions or need clarification, please contact this office at your convenience. Reference to our Job #99 -390 -F will help to expedite our response to your inquiries. V1N1E & MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, #102, Escondido, California 920291229 • Phone (760) 7431214 • Fax (760) 739.0343 GEOTECHNICAL INVESTIGATIONS GRADING SUPERVISION PFRC TESTING ENVIRONMENTAL INVESTIGATIONS Foundation Recommendations, Parcel #4, Encinitas TM #97 -201 January 17, 2000 Page 11 We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. 0 Ralph M. Vinje L; <, "I r1 Mehdi Shariat <O '?V". VS GE #863 R CE RCE #46174 w� EzP.1231 Cl <� No. 46174 RMV /MS /mpr of FOIE �E ^ • FJ(P.12-31 -02 Distribution: Addressee (6) C, � \Epf�\P mprlfi)1c t)99-396f.ag4 VINIE d MIDDLETON ENGINEERINQ, INC. 2450 Vineyard Avenue, 1102, Escondido, California 92029.1229 • Phone (760) 7434214 • Fax (760) 7390343 QEOTECHNICAL IWEST19ATIONS QRADINQSITERVISION PE RC TESTING ENVIRONMENTAL INVESTIGATIONS RETAINING WALL DRAIN DETAIL Typical - no scale dro inag a Granular, non -expansive backfill_ Compacted. Waterproofing Filter Material. Crushed rock (wrapped in filter fabric) or Class 2 Permeable Material Perforated drain pipe (see specifications below) Competent, approved' soils or bedrock CONSTRUCTION SPECIFICATIONS: SPECIFICATIONS FOR CALTRANS CLASS Z PERMEABLE MATERIAL 168. 1.025).. U.S. STANDARD SIEVE SIZE % PASSING .100 .1314 - - _90 -100 -:318. 4a -700 No, 4 - 25 -40 No .8 18 -33 Na. 30 5-15 `No. 50 0 -7 No 2DJ 0 -3 Sand Equivalent> 75 1. Provide granular, non - expansive backfill soil in 1:1 gradient wedge behind wall. Compact backfil to minimum 90% of laboratory standard. 2. Provide back drainage for wall to prevent build -up of hydrostatic pressures. Use drainage openings along base of wall or back drain system as outlined below. 3. Backdrain should consist of 4" diameter PVC pipe (Schedule 40 or equivalent) with perforations down. Drain to suitable outlet at minimum 1 %. Provide' /.' - 11/2' crushed gravel fitter wrapped in fitter fabric (Mirafl 140N or equivalent)- Delete fitter fabric wrap if Caltrans Class 2 permeable material is used. Compact Class 2 material to minimum 90% of laboratory standard. 4. Seal back of wall with waterproofing in accordance with architect's specifications. 5. Provide positive drainage to disallow ponding of water above wall. Lined drainage ditch to minimum 2% flow away from wall is recommended. Use 1Y: cubic foot per foot with granular backfill soil and 4 cubic foot per foot it expansive backfill soil is used. VINJE & MIDDLETON ENGINEERING, INC. PLATE 81 ISOLATION JOINTS AND RE- ENTRANT CORNER REINFORCEMENT Typical - no scale (a) (b) NOTES: 1. Isolation joints around the columns should be either circular as shown in (a) or diamond shaped as shown in (b). If no isolation joints are used around columns, or if the comers of the isolation joints do not meet the contraction joints, radial cracking as shown in (c)may occur (reference ACI). 2. In order to control cracking at the re- entrant corners ( ±2700 corners), provide reinforcement as shown in (c). 3. Re- entrant corner reinforcement shown herein is provided as a general guideline only and is subject to verification and changes by the project architect and /or structural engineer based upon slab geometry, location, and other engineering and construction factors. VINJE & MIDDLETON ENGINEERING, INC. PLATE 12 VINJE & MIDDLETON ENGINEERING, INC. Job 97 -145 -V April 28, 1998 Development Planning Consultants International, Inc. Attention: Mr. Zahoor Abbasi 131 South Escondido Boulevard Escondido, California 92025 2450 Vineyard Avenue, x102 Escondido, California 92029.1229 Phone (760) 743 -1214 Pax(760)739 -0343 Clarification Letter On Preliminary Geotechnical Investigation Report Job #97- 145 -V, Dated May 27, 1997, Double LL Ranch Road, Olivenhain The tentative map included in the above referenced geotechnical report has been revised with respect to parcel numbers. Therefore the following clarifications are appropriate: 1. Cut slopes in Parcel 1 and any other cut slopes within the project development exceeding five feet in maximum vertical height and exposing weaker claystone /siltstone units should be reconstructed as a stabilization fill slope at 2:1 gradients maximum as recommended in the project geotechnical report. 2. The previously addressed Parcel 3 (page 11 of the subject report) is now Parcel 2 in the revised map. The east end of the cut slope construction for this parcel may also expose weaker claystone units. In these areas where slope heights exceeds 5 vertical feet maximum. the cut bank may also reconstructed as a stabilization fill slope at 2:1 gradients. 3. All cut slope construction and stabilization for the project development should be completed under inspection and testing of the project soils engineer. Additional recommendations should be provided at time of grading and earth works based on the actual exposure, if it becomes necessary. Should any questions arise concerning this letter, please do not hesitate to contact the undersigned. Reference to our Job #97 -145 -V will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING, INC. �I r Dennis Middleton Mehdi Shariat ��4 t SH �\ CEG #980 RCE #46174 Distribution: Addressee (2) No. 46174 Pasco Engineering, Attn. Mr. Wayne Pasco (2, fax) = UP. 12 -21 -9s sms \wpdocsW- 145 -V.clr \qp CI�I�';, \prelim Preliminary Geotechnical Investigation Proposed 5 Parcel Subdivision APN 264- 240 -03 Double LL Ranch Road, Olivenhain City of Encinitas, California May 27, 1997 I Dl d MQ .0 9199d D Prepared For. Development Planning Consultants International, Inc. P.O. Box 462885 Escondido, California 92046 -2885 Job #97 -145 -V VINJE & MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, +102 Job #97 -145 -V Escondido, California 92029 -1229 Phone(760)743 -1214 May 27, 1997 Fax (760) 739.0343 Development Planning Consultants International, Inc. Attention: Mr. Zach A. Abbasi 2622 Sunset Drive Escondido, California 92025 Preliminary Geotechnical Investigation, Proposed 5 -Lot Subdivision, Double II Ranch Road Olivenhain City of Encinitas. California (APN 264 -240 -03) Pursuant to your request, Vinje & Middleton Engineering, Inc. has completed the attached investigation of soils and geotechnical conditions at the subject site. The following report summarizes the findings of our subsurface investigation, including field and laboratory test results, analyses and conclusions, and provides recommendations for the site development as understood. From a geotechnical engineering standpoint. it is our opinion that the site is suitable for the proposed development provided the recommendations presented in this report are incorporated into the design and construction of the project. The conclusions and recommendations provided in this study are consistent with the site geotechnical conditions and are intended to aid in preparation of final plans and allow more accurate estimates of development costs. Thank you for choosing Vinje & Middleton Engineering, Inc. If you have any questions concerning this report, please do not hesitate to call us. Reference to our Job # 97 -145 -P will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. VINJE & MIDDLETON ENGINEERING. INC. ft7arph M. Vinje GE #863 RMV /mmd x No.863 * c�,EV-12- 31.97 Or \Ja TECHN�� 0�P CF C A0i Table of Contents I. Introduction ..................... ............................... 1 II. Site Description ................. ............................... 1 III. Site Investigation ................ ............................... 1 IV. Proposed Development ........... ............................... 2 V. Findings ........................ ............................... 2 A. Earth Materials ............... ............................... 2 B. Slope Stability ................ ............................... 3 C. Geologic Structure ............ ............................... 3 D. Ground Water ................ ............................... 4 E. Faults /Seismicity ............. ............................... 4 F. Geologic Hazards ............. ............................... 6 G. Field and Laboratory Testing ... ............................... 6 VI. Conclusions .................... ............................... 9 VII. Recommendations .............. ............................... 10 A. Site Specific Grading and Earthworks Recommendations .......... 10 B. General Grading and Earthworks Recommendation ............... 11 C. Foundation and Interior Floor Slabs ............................ 15 D. Exterior Concrete Slabs /Flatworks ............................. 16 E. Foundation and Earth Pressures ............................... 17 F. Pavement Design ............ ............................... 18 G. General Recommendations .... ............................... 18 VIII. Limitations .................... ............................... 20 TABLES Fault Zones .......................... ............................... 1 Soil /Rock Type ....................... ............................... 2 Maximum Dry Density and Optimum Moisture Content ..................... 3 In -Place Dry Density and Moisture Content ............................... 4 Grain Size Analysis .................... ............................... 5 Liquid Limit, Plastic Limit and Plasticity Index ............................ 6 Expansion Test ....................... ............................... 7 Expansion Index Test .................. ............................... 8 Direct Shear Test ..................... ............................... 9 Removal Depths /Exploratory Test Excavations .......................... 10 Table of Contents Continued PLATES Geotechnical Map ..................... ............................... 1 Test Trench Logs .................................................. 2 -7 BoringLogs .......................... ...........................8 -13 Geologic Cross - Sections .............. ............................... 14 Fault - Epicenter Map ................. ............................... 15 Typical Pad Construction Details ....... ............................... 16 Key and Benching Details ......... ............................... 17 & 18 Isolation Joints and Re- Entrant Corner Reinforcement .................... 19 Typical Retaining Wall Drain Detail ...... ............................... 20 Preliminary Geotechnical Investigation Proposed 5 Parcel Subdivision (APN 264 - 240 -03) Double LL Ranch Road, Olivenhain, City of Encinitas I. INTRODUCTION The property investigated in this work includes 15.72 acres of undeveloped hillside terrain south of Double LL Ranch Road in the Olivenhain district of the City of Encinitas. We understand that the property will be divided into parcels for individual grading and residential development. Consequently, the purpose of this investigation was to determine geologic and soils conditions beneath the property and their influence upon the proposed development. Geologic mapping, test trenching, drilling, soil sampling and laboratory testing were conducted in connection with this study which allowed the development of planning and construction recommendations presented herein. 11, SITE DESCRIPTION Details of site topographic conditions are depicted on a Geotechnical Map enclosed with this report as Plate 1. The property is characterized by gentle to moderately steep hillside terrain which ascends in a southern direction from lower areas along Double LL Ranch Road onto higher more level areas along the south margin. A maximum elevation difference of 130 feet is indicated. Site drainage flows northward across the property concentrating in center canyon areas that drain northeastward along Double LL Ranch Road. Natural drainage is disrupted by an old earth filled dam in the center areas as shown on Plate 1. Lower slope terrain of the property is mantled by a moderate cover of native grasses Upper canyon areas support larger trees. Man made features at the site include a network of unimproved roads, the old dam structure and a large- diameter water line across Parcels 1 and 2 (see Plate 1) Ill. SITE INVESTIGATION Geotechnical conditions at the project site were determined from geologic mapping of available site exposures and the excavation of twelve test trenches dug with a tractor - mounted backhoe. Deeper exposures were developed in six test borings drilled in selected locations by a truck - mounted drill. Five of the borings and all of the test trenches were entered and logged by our project geologist who also retained bulk and relatively undisturbed soil /rock sample for laboratory testing. Laboratory test result are presented in VINIE d MIDDLETON ENQINEERINCJ, INC. 1450 Vineyard Avenue, #102, Ee ... did., C.Ii(omiu 92029 -1229 • Phone (760) 7434214 • Fos (760) 739.0343 SOILTES INQ PERC TEST SOIL INVESfIQAVON5 CEOTECHNICAL INVESfIQATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 2 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 a following section. Borings and trench locations are shown on Plate 1. Logs of the excavations are attached to this report as Plates 2 - 13. IV. PROPOSED DEVELOPMENT Details of the site development are presently unknown. However, preliminary plans for individual lot grading are depicted on Plate 1. As shown, Parcels 1 through 3 will consist of graded cut -fill building pads developed within the hillside. Parcel 4 is a cut pad surface. The grading scheme for the remaining property (along the east margin) is not yet developed. Graded slopes at the project site will be on the order of 20 feet high programed for 2:1 (horizontal to vertical) gradients. Private drives will provide access to the pads from a common entrance roadway off Double LL Ranch Road as shown. Details of the proposed building construction are not yet developed. We understand, however, that conventional wood stud bearing wall structures with stucco exterior supported on shallow concrete footing and slab -on -grade foundations are planned. V. FINDINGS The study property is situated in a hillside terrain with intervening canyons underlain by marine sedimentary rocks of Eocene Age. Two formational bedrock units are present at the site which are characterized by different engineering properties. Upper slope terrain exposed sandstone units which experience high rates of erosion when subjected to uncontrolled runoff. Lower slopes are underlain by claystone /siltstone units which are inherently unstable sediments that are often associated with geologic slope instability in nearby areas. Canyon terrain is occupied by natural alluvial soils and a fill deposit is present in the lower central portion. A. Earth Materials The following earth deposits are recognized at the project site: Bedrock (Td) - Lower slope terrain at the property are underlain by claystone units with minor siltstone /sandstone. These rocks are characterized by a distinctive green color and the development of a thick clay -rich topsoil cover. Claystone units at the project site are typically deeply weathered to a weak condition and occur in gentle slope configuration which is the result of long term slope instability- Local claystone units and the overlying topsoil are highly expansive deposits as indicated by ground surface cracks commonly in excess of 1 inch wide and 1 foot deep throughout the lower site terrain. VINIE B MIDDLETON ENQINEERINQ, INC. 2450 Vineyard Avenue, ♦102, Escondido, California 92019.1129 • Phone (760) 743 -1214 • I= (760) 739-0343 SOIL TESTING PERC TEST SOIL IMTSTIQATIONS CEOTECNNICAL INVESTIGATIOM PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 3 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27. 1997 Bedrock (Tt) - Upper project slopes are underlain by younger sandstone deposits approximately as shown on Plate 1. These units are characterized by their light color and the development of steeper "badlands" topography throughout upper site terrain. Sandstone units at the project site are non - expansive, stable deposits which typically perform well in grade slopes that are properly maintained. Alluvium (Qal) - Natural alluvial soils occupy lower canyon terrain at the project site. The alluvium consists chiefly of silty sands with clay which occur in a loose condition. Fill (af) - Fill soils occur in the lower, central areas of the site approximately as shown on Plate 1. The fills were likely placed as an old agricultural dam structure. Fill soils consist chiefly of sandy soils in a loose condition. Additional fill soils occur along the north margin of the property in support of Double LL Ranch Road and are reported to occur along the base of the natural slope in the lower reaches of Parcel 3, (see Plates 1 - 14). The latter deposit is thought to have been placed as a stabilization fill during a previous development effort. Details of the fill are unknown; however, it is not expected to impact present development plans. The approximate distribution of major earth materials at the project site is indicated on the enclosed Geotechnical Map, Plate 1. Details of site deposits are given on Plates 2 - 13. B. Slope Stability Most areas of the study site are underlain by claystone /siltstone units (Td) which are inherently weak materials that perform poorly in slope conditions. Landslides are often associated with these deposits in local hillside areas. Existing landslide features are not indicated at the study site, however, development techniques utilized at the project should be consistent with these sensitive deposits and utilize appropriate grading methods which will help insure the stability of graded sites. Grading recommendations are presented in a following section. Grading within upper project slope areas will expose light colored sandstone units (Tt) which typically perform well with regard to gross geologic stability. However, these units experience high rates of erosion when subjected to uncontrolled surface runoff. C. Geoloqic Structure The prominent geologic structure at the project site consists of bedding relationships between dissimilar earth deposits. Major earth deposits in the area are conformable. Structural attitudes were recorded chiefly within boring excavations along sandstone - claystone contacts. Most of the data indicate nearly horizontal structure within the VIN1E N MIDDLETON ENQINEERIN(T, INC. 1450 Vineyard Ao w, 0102, Escondido, Calgomia 91029 -1229 • Pho (760) 743 -1114 • F= (760) 739 -0343 SOIL TEWINCI PERC TEST SOIL INVESTIQAMM CIEOT CHNICAL INVESTIC�AMM PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 4 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 section; however, low angle dips to the southwest are suggested by the outcrop pattern of the sandstone (Tt) and claystone (Tt) sections. This is a favorable orientation with regard to the overall geologic stability of project slopes. D. Ground Water Significant ground water conditions are not indicated at the project site. Slight water seepage was recorded in selected test borings chiefly at sandstone - claystone contacts. These conditions are not expected to impact project development. However, earth materials at the site commonly transmits subsurface waters in lateral directions from off -site watershed areas above. Consequently, site improvements located near the toe of ascending slopes should be protected by perimeter subdrains and earth- fill /retaining structures should be provided with backdrains as recommended in a following section. Grading records associated with the construction of Double LL Ranch Road indicate that a subdrain was placed beneath the roadway fill and outlets in the north perimeter of the study site approximately as shown on Plate 1. E. Faults /Seismicity Faults or significant shear zones are not indicated on or near proximity to the project site. As with most areas of California, the San Diego region lies within a seismically active zone, however, coastal areas of the county are characterized by low levels of seismic activity relative to inland areas to the east. During a 40 year period (1934- 1974), 37 earthquakes were recorded in San Diego coastal areas by the California Institute of Technology. None of the recorded events exceeded a Richter magnitude of 3.7, nor did any of the earthquakes generate more than modest ground shaking or significant damages. Most of the recorded events occurred along various offshore faults which characteristically generate modest earthquakes. Historically, the most significant earthquake events which affect local areas originate along well known, distant fault zones to the east and the Coronado Bank fault to the west. Based upon available seismic data, compiled from California Earthquake Catalogs, the most significant historical event in the area of the study site occurred in 1800 at an estimated distance of 7 miles from the project area. This event, which is thought to have occurred along as off -shore fault, reached an estimated magnitude of 6.5 with estimated bedrock acceleration values of .379g at the project site. The following list represents the most significant faults which commonly impact the region. Estimated ground acceleration data compiled from Digitized California Faults (Computer Program EQ Fault Ver. 2:01) typically associated with the fault is also tabulated. VINJE 9 MIDDLETON ENQINEERINGI, INC. 1450 Vineyard Avenue, $102, Ettu lido, Calgomia 92019 -1229 • Pho (760) 743 -1214 • Paz (760) 739.0343 SOIL TFSTrK PERC TEST SOIL IN WIGATIONS GEOTECNMCAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 5 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 Tahlr 1 FAULTZONE DISTANCE FROM SITE MAXIMUM PROBABLE ACCELERATION R.H. Elsinore Fault 24 miles 0.116 g San Jacinto Fault 48 miles 0.059 g Coronado Bank Fault 23 miles 0 137 The location of significant faults and earthquake events relative to the study site are depicted on a Fault - Epicenter Map attached to this report as Plate 15. More recently, the number of seismic events which affect the region appears to have heightened somewhat. Nearly 40 earthquakes of magnitude 3.5 or higher have been recorded in coastal regions between January, 1984 and August, 1986. Most of the earthquakes are thought to have been generated along offshore faults. For the most part, the recorded events remain moderate shocks which typically resulted in low levels of ground shaking to local areas. A notable exception to this pattern was recorded on July 13, 1986. An earthquake of magnitude 5.3 shook County coastal areas with moderate to locally heavy ground shaking resulting in $700,000 in damages, one death, and injuries to 30 people. The quake occurred along an offshore fault located nearly 30 miles southwest of Oceanside. A series of notable events shook County areas with a (maximum) magnitude 7.4 shock in the early morning of June 28, 1992. These quakes originated along related segments of the San Andreas Fault approximately 90 miles to the north. Locally high levels of ground shaking over an extended period of time resulted, however, significant damages to local structures were not reported. The increase in earthquake frequency in the region remains a subject of speculation among geologists; however, based upon empirical information and the recorded seismic history of county areas, the 1986 and 1992 events are thought to represent the highest levels of ground shaking which can be expected at the study site as a result of seismic activity. In recent years, the Rose Canyon Fault has received added attention from geologists. The fault is a significant structural feature in metropolitan San Diego which includes a series of parallel breaks trending southward from La Jolla Cove through San Diego Bay toward the Mexican border. Recent trenching along the fault in Rose Canyon indicated that at that location the fault was last active 6,000 to 9,000 years ago. Thus, the fault is classified as "active" by the State of California which defines faults that evidence displacement in the previous 11,000 years as active. More active faults (listed on the preceding page) are considered most likely to impact the region during the lifetime of the project. The faults are periodically active and VINJE & MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue. #102, E .... dida, Ca 4.f ,a 92029-1229 • Phone (760) 743.1214 • I= (760) 739,0343 SOIL TTST M, PERC TEST MOIL INVESTIQATIONS QEOTECHNICAL INVESPIQAiIOM PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 6 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 capable of generating moderate to locally high levels of ground shaking site. Ground separation as a result of seismic activity is not expected at the property. F. Geologic Hazards Geologic hazards are not presently indicated at the project site. The most significant geologic hazards at the property will be those associated with ground shaking in the event of a major seismic event. Liquefaction or related ground rupture failures are not anticipated. Larger graded cut slopes in the lower reaches of the property will likely expose unstable sedimentary rocks. G. Field and Laboratory Testing The condition of site earth deposits were visually evaluated by logging the test excavations and performing Standard Penetration Tests (SPT). In addition, representative undisturbed ring and bulk samples were retained for subsequent laboratory testing. Sample intervals within test excavations are indicated on the attached logs. Based upon our test data and field exposures, site soils have been grouped into the following soil types. TABLE 2 SoitfRock Type Description 1 dark to olive brown sandy to silty clay (topsoils) 2 olive-green to grey cla stone (bedrock) 3 tan to brown fine grained sandstone (bedrock) The following summarizes test procedures and tabulates laboratory test results of retained samples: 1. Standard Penetration Tests: Standard Penetration Tests (SPT) were performed at the time of bore hole drilling in accordance with the ASTM Standard Procedure D1586 using rope and cathead. Test results are indicated on the corresponding locations on the boring logs 2. Maximum Dry Density and Optimum Moisture Content: The maximum dry density and optimum moisture content of Soil Types 2 and 3 were determined in accordance with ASTM D- 1557 -91. The results are tabulated on Table 3 located on the following page. VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, #102, Escondido, California 92029/229 • Phone (760) 7431214 • I= (760) 739.0343 SOIL TESTING PERC TEST SOIL INVESTIGATIONS GEOTECHNICAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 7 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 TARI F 7 Location Soil Type Maximum Dry Density m- c Optimum Moisture Content mo t'!o T -1 @ 5' 2 111 3 178 T -3 @ 8' 3 119.9 11.2 3. In -Place Dry Density and Moisture Content: In -place dry density and moisture content of representative soil deposits beneath the site were determined from relatively undisturbed ring and chunk samples using weights and measurements, and water displacement method respectively. Results are presented Table 4 below and tabulated on the attached Test Trench and Boring Logs. TARI F d Sample Location Soil T e Field Moisture Content m -a/a Field Dry Density Yd- c Max. Dry Density Ym• c Ratio of In-Place Dry Density to Max. Dry Density Yd[Ym x100 T-5 @ 5 2 21.8 82.2 111.3 744 T -9 @ 5' 3 11.0 119.0 119.9 992 T -10 V 4' 2 17.7 106.7 111.3 95.9 T -12 @ 7' 2 13.3 120.0 111.3 100+ 8-2 6 1 2 20.6 1 98.4 111.4 88.3 B -3 @ 7' 3 12.0 115.6 119.9 96.4 B -4 C5 8' 3 78 119.6 119.9 997 B -5 @ 10' 2 11.9 116.3 111.3 100+ 8-6 @ 5' 4 14.7 110.2 - B -6 1 C. 4 14.8 112.8 - - S' 4. Grain Size Analysis: Grain size analysis was performed on a representative sample of Soil Type 4. The test result is tabulated in Table 5 below IF -\anyi Sieve Size W. 1 /s" #4 1 #30 #100 #200 Location Soil Type Percent Passing B -6 @ 10' 4 100 100 99 1 92 77 62 VINIE N MIDDLETON ENCIINEER1N(3, INC. 2450 Vineya+d Awnwe, 0102, Escondido, Wifomia 91029.1219 • Phonc (760) 743 -1214 • Fa (760) 739 -0343 SOIL TE.RING PFRC TEST SOIL INVESTIGATIONS GEOTECT ICAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 8 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27. 1997 5. Liguid Limit Plastic Limit and Plasticity Index: Liquid limit, plastic limit and plasticity index tests was performed on a representative sample of Soil Type 4 in accordance with the ASTM D- 4318 -84. The test result is tabulated below on Table 6: Location Soil T Liquid Limit % Plastic Limit % Plasticity tndex PI B -6 @ 10' 4 1 41 1 16 1 25 6. Expansion Test: One expansion index test was performed on a representative sample of Soil Type 2. The soil sample was remolded to 90% of the corresponding maximum dry density in a 2' /z inch diameter, 1 inch high ring mold. The sample was instrumented, loaded with 1 psi, and submerged in water. The ratio of the change in height from the air dry to the saturated condition is defined as the percent expansion. The test result is presented in Table 7: i1111211.111111;&A Sample Location Soil Type Initial w% Air Dry (W "/° Saturated w '/ Expansion % Expansion Potential T -1 @ 5 2 19 4 1 145 1 33 9 1 15 6 critical = moisture content in percent 7. Expansion Index Test: One expansion index test was performed on representative samples of Soil Type 4 in accordance with the Uniform Building Code Standard 18 -2. The test result is presented in Table 8 below: TARt F A Sample Location Soil Type Remolded w % Saturation % Saturated w % Expansion Index E! Expansion Potential B -6 Q 10' 4 144 1 51 1 1 23.8 1 95 High (w) = moisture content in percent 8. Direct Shear Test: Two direct shear tests were performed on representative samples of Soil Types 2 and 3. Prepared specimens were soaked overnight. loaded with normal loads of 1, 2, and 4 Kips per square foot respectively, and sheared to failure in an undrained condition. Results are presented on Table 9 located on the following page: VINJE d MIDDLETON ENGINEERING, INC. 2450 Vineyard Awnue, #102, Esondido, California 92029 -1219 • Phone (760) 743 -1214 • Fns (760) 739 -0343 Sob TESTING PERC TEST SOIL INVESTIGATIONS QEOTECTINICAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 9 DOUBLE LL RANCH ROAD, OLIVENHAIN MAY 27, 1997 TABLE 9 VI. CONCLUSIONS Based upon the forgoing investigation, development of the project site for residential purposes is feasible from a geotechnical viewpoint. Unusual grading problems are not expected, however, project earth materials should be treated in accordance with their unique engineering properties. The following factors should be considered in project planning: Project alluvial and topsoils are loose, expansive deposits which in their present conditions are not suitable for the support of structures and improvements. Soils generated from siltstone /claystone (Td) and site topsoil excavations are chiefly highly expansive units which should comprise deeper project fills. Soils generated from sandstone units (Tt) are non - expansive granular soils which may be utilized as compacted cap soils at finish project grades. ` Grading operations conducted within claystone /siltstone units (Td) should utilize special procedures in view of their inherent weakness. Cut slopes should be supported by graded stabilization fills and fill slopes must be founded in a suitable depth below upper weathered units. Detail recommendations for these procedures are provided in a following section. ' Subdrain systems are recommended to protect improvements constructed near ascending cut slopes and along the base of supporting fill and wall structures. Recommendations are provided in the following section. ' Liquefaction and seismically induced settlements and will not impact the proposed development and structures provided our recommendations for remedial grading and site development are followed. ' Post construction settlements of the underlying earth deposits are expected to be within the allowable tolerances of the building foundations and floor slab provided our recommendations for site development are implemented. VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, •102, Escondido, California 920294219 • Phone (760) 743 -1214 • Fax (760) 7390343 SOIL TMINQ PERC= SOIL INVESTIQATIONS QE0TECHMC.4 INVFSTIQATIONS Wet Angle of Apparent Sample Soil Sample Density Int. Fric. Cohesion Location Type Condition D T -1 (7c 1 2 90% Remolded 117.2 24 287 6-3 0 8' 3 90% Remolded 118.8 38 181 VI. CONCLUSIONS Based upon the forgoing investigation, development of the project site for residential purposes is feasible from a geotechnical viewpoint. Unusual grading problems are not expected, however, project earth materials should be treated in accordance with their unique engineering properties. The following factors should be considered in project planning: Project alluvial and topsoils are loose, expansive deposits which in their present conditions are not suitable for the support of structures and improvements. Soils generated from siltstone /claystone (Td) and site topsoil excavations are chiefly highly expansive units which should comprise deeper project fills. Soils generated from sandstone units (Tt) are non - expansive granular soils which may be utilized as compacted cap soils at finish project grades. ` Grading operations conducted within claystone /siltstone units (Td) should utilize special procedures in view of their inherent weakness. Cut slopes should be supported by graded stabilization fills and fill slopes must be founded in a suitable depth below upper weathered units. Detail recommendations for these procedures are provided in a following section. ' Subdrain systems are recommended to protect improvements constructed near ascending cut slopes and along the base of supporting fill and wall structures. Recommendations are provided in the following section. ' Liquefaction and seismically induced settlements and will not impact the proposed development and structures provided our recommendations for remedial grading and site development are followed. ' Post construction settlements of the underlying earth deposits are expected to be within the allowable tolerances of the building foundations and floor slab provided our recommendations for site development are implemented. VIN1E 9 MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, •102, Escondido, California 920294219 • Phone (760) 743 -1214 • Fax (760) 7390343 SOIL TMINQ PERC= SOIL INVESTIQATIONS QE0TECHMC.4 INVFSTIQATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 10 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 Soil collapse will not be a factor in development of the study site provided our recommendations for site development are followed. Ground water will not be a factor in the development of the study site as planned. VII. RECOMMENDATIONS The following recommendations are consistent with site geotechnical conditions and should be incorporated into finalized plans and implemented during the construction phase: A. Site Specific Grading and Earthworks Recommendations 1. Parcel 1- The upper cut slope should be supported by a stabilization fill structure composed of compacted site soils. The keyway for the stabilization fill should be placed a minimum depth of 2 feet below pad grade and maintain a minimum width of 12 feet. A subdrain system which outlets at the south of the fill should be provided. The cut portion of the graded pad should be additionally undercut a minimum of 4 feet and the building pad capped to design grade with compacted non - expansive soils The lower fill section for Parcel 1 should be placed within less weathered, competent bedrock units which occur at depths of 5 to 15 feet below the proposed fill toe. A subdrain system should be provided which outlets near the south end of the fill Typical details of the above work are depicted on a Pad Construction Detail Plate attached herein as Plate 16. 2. Parcel 2- The upper cut slope should be supported by a stabilization fill structure composed of compacted site soils. The keyway for the stabilization fill should be placed a minimum depth of 2 feet below pad grade and maintain a minimum width of 8 feet. A subdrain system which outlets at the south end of the fill should be provided. The cut portion of the graded pad should be additionally undercut 3 feet and the building pad capped to design grades with compacted, non - expansive soils. The lower fill section for Parcel 2 should be placed within more dense alluvial soils which occur at depths of 5 feet below existing surface grades. Actual removal depths in these areas may vary and should be determined in the field when actual exposures are available. Typical details for the work are depicted on Plate 16. VIN3E B MIDDLETON ENGINEERING, INC. 2450 Vingnrd Avc .0 , #102, Escondido, C'uli /omia 92029-1229 • Phone (760) 743 -1214 • Fa (760) 739 -0343 SOIL MWfNQ PERC TES( 5/111. 1.1T_STIGATIONS GLOTE CAL INV QATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 11 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 Attempts should be made during grading of Parcel 2 to locate the reported subdrain from beneath Double LL Ranch Road Based upon its location, an appropriate re- alignment should be constructed. 3. Parcel 3- The upper cut slope is expected to expose competent sandstone units. Regrading of the slope is not anticipated. The east end of the slope may expose weaker daystone units. The slope may be constructed at a reduced gradient of 3:1 or supported with a four -foot high retaining wall provided with 18 inches of upper freeboard. The cut portion of the building pad should be additionally undercut three feet and the graded pad capped to design grades utilizing compacted, non - expansive soils. The fills should be sufficiently keyed into competent bedrock units within the hillside. Estimated removal depths are not expected to exceed 10 feet below existing grades. A subdrain system should be provided which may outlet in the natural drainage below the east end of the building pad. Details of the above recommended procedures are depicted on a Typcial Pad Construction Detail plate attached to this report as Plate 16. 4. Parcel 4- Parcel 4 will consist of graded cut lot exposing non- expansive sandstone deposits at near grade elevations. Special grading provisions for soil improvements are not indicated. 5. Remaining Property- Grading scheme for the remaining property (along the east margin), was not available at the time of this study. Specific grading and stabilization recommendations should be provided when design grades are developed. B. General Grading and Earthworks Recommendation Conventional selected grading techniques may be used in order to achieve final design grades and improve soil conditions beneath the new structures and improvements. All grading and earthworks should be completed in accordance with Appendix Chapter 33 of the Uniform Building Code, local grading ordinances and the requirements of the following section wherever applicable. 1. Cleaning and Grubbing: Surface vegetation and other deleterious materials and debris should be removed from areas of the site planned for fill, structures and improvements. Removals should be inspected and approved by the project geotechnical engineer or his designated field representative prior to grading. VTNJE B MIDDIETON ENGINEERING, INC. 2450 Vineyard Avenue, #102, Escondido, California 92029 -1219 x Phone (760) 743 -1114 a Fax (760) 739 -0343 SOIL=INCI PERC TP-%r SOIL INT- MQATIONS GEOTECHNICAL INVF_ QATIOM PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 12 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 2. Grading: Site existing upper topsoils and alluvial deposits should be removed to the depths recommended herein in all areas to receive fills and/or structures /improvements. Approximate removal depths in the vicinity of individual exploratory test excavations are shown on Table 10. Locally deeper removals may be necessary based on the actual field exposures and should be anticipated. Removals associated with soil improvements and site stability provided in the Site Specific Grading and Earthworks Recommendation section of this report will supersede the values furnished in Table 10 below where applicable. Teai F 1n Exploratory Excavation No. Total Depth of Exploratory Excavation Estimated Depth to Groundwater ft Estimated Removal Depths ft Comments T -1 7' N/E 2%z' Also seespecific grading recommendations T -2 7' N/E 4' " T -3 12 N/E 8''A' R &R not required where no grading planned T -4 6 WE 2' T -5 5' WE 3' Road improvements T -6 6 N/E 3' " T -7 5' WE 5' " T -8 13' N/E 2' R &R not required where no grading planned T -9 7' N/E 3' Also seespecific grading recommendations T -10 7' N/E 2' " T -11 8' N/E 6' R &R not required where no grading planned T -12 8' WE 3% Also seespecific grading recommendations B -2 32' seepage @ 15' 15' " B -3 25' WE 3' " B -4 38' N/E 2' R &R not required where no grading planned B -5 17' N/E 5' Also seespecific grading recommendabons Notes. 1. All depths are measured from the existing ground levels except where specifically indicated. 2. Actual depths may vary at the time of construction based on seasonal conditions and actual subsurface exposures. 3. Bottom of all removals should be ripped and recompacted as directed in the field. 4. N /E: Not Encountered. VINIE 9 MIDDLETON ENQINEERINCG, INC. 2450 Vineyard Avenue, #102, Escondido, California 92029.1229 • Phone (760) 7434214 • Fa: (760) 739.0343 SOIL TFSTM. PERC TEST SOIL INVESTIGATIONS CEOTECHNICAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 13 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 3. Temporary Construction Slopes: Temporary construction slopes required during removal operations and at the time of stabilization fill slope construction should not exceed 1:1 gradients maximum. Minor sloughing the temporary slopes may occur and should be anticipated. Temporary support and shoring may also be required for the protection of the culvert during the removal operations and should be anticipated. 4. Select Grading: Expansive soils are present at the site. Attempts should be made to bury the potentially expansive soils in deeper fills and placing non - expansive sandy soils available from the excavation of on -site sandstone deposits within the upper 3 to 4 feet (see Site Specific Grading and Earthworks Recommendation) of the building pad grade and 1 foot of internal road improvements using select grading techniques. There should be a minimum of 1 foot of non - expansive compacted soils below the deepest footing. 5. Graded Slopes: Graded cut and fill slopes at the project site should be programmed for 2:1 gradients maximum. a) Cut Slopes: Graded cut slopes planned on Parcels 1 and 2 should be reconstructed as a stabilization fill slopes. For this purpose a keyway should be established at the toe of the slope as specified in the Site Specific Grading and Earthworks Recommendation section. The keyway should be heeled back a minimum of 2% into the natural hillside. Actual keyway dimensions should be determined in the field based upon actual exposures. Suitable level benches which are slightly heeled back into the competent natural hillside should be constructed as required. Reconstructed slope should maintain finish gradients no steeper than 2:1 (horizontal to vertical) and compacted to minimum 90% out to the slope face. Overbuilding and cutting back to the compacted core or backrolling at minimum three -feet vertical increments and "track- walking" the slope face is recommended. b) Fill Slopes: Graded fill slopes planned on Parcels 1, 2, and 3 provided with deepened keyways as specified in the Site Specific Grading and Earthworks Recommendation section. Fill slopes should maintain finish gradients no steeper than 2:1 (horizontal to vertical) and compacted to minimum 90% out to the slope face. Overbuilding and cutting back to the compacted core or backrolling at minimum three feet vertical increments and "track- walking" the slope face is recommended. c) Subdrainage System: The stabilization slopes and lower fill slopes on Parcels 1, 2, and 3 should also be provided with adequate subdrainage drainage systems. The subdrainage systems should consist of a drain pipe wrapped in filter materials. Minimum 4 -inch diameter Sch. 40 (or SDR 35) perforated drain pipe surrounded with VIN3E 6 MIDDLETON ENGINEERING. INC. 1450 Vineyard Aa,,,. , #102, Esanndidu, (Uifum,a 92029,1229 • Phone (760) 7431214 • Pax (760) 7390343 SOIL=INCj PERCTEST SOIL IMT:.STIGATIONS QEOTECH ICAL INVF_STIQAT10NS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 14 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 a minimum of 4 cubic feet per foot of /4 -inch crushed rocks wrapped in Mirafi 140N filter fabric or 4 cubic feet per foot of Caltrans Class 2 filter materials should be used. The filter fabric may be deleted if Caltrans Class 2 is used. The subdrains should be installed at suitable elevations in the keyway stabilization /fill slope in order to provide positive drainage at a minimum of 1 % gradient onto an approved outlet as shown on the enclosed Typical Pad Construction Detail, Plate 16. d) General: Reconstructed cut and fill slopes programed for 2:1 gradients maximum will be grossly stable with respect to deep seated and surface failures for the proposed maximum design heights provided our recommendations for slope construction are followed. Periodic inspection of the cullstability and fill slopes will be necessary by the project geotechnical consultant during the construction phase. Additional recommendations should also be given at the time of grading operations based on the actual field exposures developed at the site. All slope construction should also be completed in general accordance with the enclosed Plates 17 and 18. 6. CutlFill Transition: Cut/fill transition should not be allowed under buildings and the associated structures The cut portion of the cut/fill transition pad should be undercut a minimum of 3 to 4 feet (also see Site Specific Grading and Earthworks Recommendation) or one -foot below the deepest footing, whichever is more. and placed back as compacted fill. At the project site placement of at least 3 to 4 feet of non - expansive capping soils over the entire pad using select grading techniques will eliminate cut/fill transition. The non - expansive compacted fill cap over the site will also allow more conventional footing and slab design as recommended in the following sections. 7. Compaction: Fill soils should be moisture conditioned to near optimum moisture level and mechanically compacted in thin, horizontal lifts to at least 90% of the corresponding laboratory maximum density value (ASTM D- 1557 -91) unless otherwise specified. 8. Engineering Inspections: All grading operations including removals, suitability of earth deposits used as compacted fill, and compaction procedures should be continuously inspected and tested by the project geotechnical consultant and presented in the final as- graded compaction report. The nature of finished grade soils should also be confirmed in the final compaction report at the completion of grading. VINJE B MIDDLETON ENGINEERING, INC. 2450 Vineyard Awm c, 1102, Escondido, Ca ifomia 92029.1229 • Phone (760) 743.1214 • F= (760) 739 -0343 S0ILTESTING PERC TEST SOIL INVF_1TIGATIONS GEOTECHNICAL INVF_STIGAM7 PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 15 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 9. Drainage /Erosion Control: A critical element to the continued stability of the graded building pads and slopes is adequate surface drainage system, and protection of the slope face. This can most effectively be achieved by appropriate vegetation cover and the installation of the following systems: a) Drainage swales should be provided at the top and toe of the slopes per project civil engineer design. b) Building pad and slope surface runoff should be collected and directed to a selected location in a controlled manner. c) The finish slope should be planted soon after completion of grading. Unprotected slope faces will be subject to severe erosion and should not be allowed. Over watering of the slope faces should also not be allowed. Only the amount of water to sustain vegetation life should be provided. C. Foundations and Interior Floor Slabs The proposed buildings can be supported on stiff shallow foundations. The shallow foundations should be founded on properly compacted non - expansive soils. Acceptable foundations should include a system of spread pad and strip footings, and slab -on- grade floors. There should be at least one -foot of non - expansive soils below the deepest footing. All foundations and slab recommendations should be confirmed and /or revised in the final as- graded compaction report based on actual testing of the finish grade earth materials. 1. Continuous strip foundations should be sized at least at 15 inches wide and 18 inches deep for conventional one and two story wood and stucco residential buildings. Spread pad footings should be at least 24 inches square and 18 inches deep. All depths are measured from the lowest finish rough grade not including the recommended sand underlay beneath the slabs. 2. Continuous strip foundations should be reinforced with minimum 444 reinforcing bars. Place 244 bars 3 inches above the bottom of the footing and 244 bars 3 inches below the top of the footing. Reinforcement for the spread pad footings should be designed by the project structural engineer. 1 Interior and exterior pad footings for buildings planned on Parcels 1, 2 and 3 should be tied to the exterior continuous strip footings in both directions with bond beams. The bond beams should be designed so that they can span up to 10 feet as a simple beam or 5 feet as a cantilever beam (for corners) while limiting the maximum deflections to no more than 11360 of the span. The bond beams, however, should not be less than 15 inches wide by 18 inches deep and should be reinforced with minimum 244 bars top and bottom and #3 ties at 18 inches on centers maximum. VIN1E B MIDDLE? ON ENUINEERINQ. INC. 1450 Vineyard Avenue, #101, Eseondido, California 92019 -1129 • Phone (760) 743.1214 • Fax (760) 739,0343 SOIL TFSPINCS PERC TEST SOIL INVESTIGATIONS GEOTECNNICAL INVEMQATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 16 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 More specific recommendations should be given at the time of foundation plan review when details of the planned construction is known. 4. All interior slabs should be a minimum of 4 inches in thickness and reinforced with #3 bars spaced 18 inches on center each way placed mid - height in the slab. Slabs should be underlain with 4 inches of clean sand (SE 30 or greater). Place a 6 mil plastic moisture barrier mid - height in the clean sand. 5. Provide contraction joints consisting of sawcuts spaced 10 feet on center each way within 24 hours of concrete pour for all interior slabs. The sawcuts should be a minimum of 3/4 -inch in depth and should not exceed 1'/4 -inch in depth or the reinforcing may be damaged. 6. Provide re- entrant corner reinforcement for all interior slabs. Re- entrant corners will depend on slab geometry and /or interior column locations. Enclosed Plate 19 may be used as a general guideline. D. Exterior Concrete Slabs /Flatworks 1. All exterior slabs (walkways, and patios) should be a minimum of 4 inches in thickness reinforced with 6x6/10x10 welded wire mesh placed at mid - height of the slab. 2. PCC driveways and parking should be a minimum of 5 inches in thickness and reinforced with #3 reinforcing bars spaced 18 inches on center each way, placed at mid - height of the slab. Subgrade soils beneath the PCC driveways and parking should be compacted to a minimum of 95% of the corresponding maximum dry density within the upper one -foot. 3 Provide weak joints consisting of sawcuts spaced 10 feet on center (not to exceed 12 feet maximum) each way within 24 hours of concrete pour. The sawcuts should be a minimum depth of /4 -inch but should not exceed 1% -inch deep. 4. All exterior slab designs should be confirmed in the final as- graded compaction report. VINJE B MIDDLETON EN(;INEERING, INC. 2450 Vineyard Avenue, #102, E =lido, California 92029.1229 • Phone (760) 743 -1214 • Fu (760) 739 -0343 SOIL TESTING PERC TEST FOIL INVESTIGATIONS GEOTECHMCAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 17 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27. 1997 E. Foundation and Earth Pressures 1. Allowable Foundation and Lateral Pressures a) An allowable foundation pressure of 1,500 pounds per square foot may be utilized for sandy non - expansive foundation bearing soils. The allowable foundation pressures provided herein apply to dead plus live loads and may be increased by one -third for wind and seismic loading. b) An allowable lateral bearing pressure of 150 pounds per square foot per foot of depth may also be used. The lateral bearing earth pressure may be increased by the amount of the designated value for each additional foot of depth to a maximum of 1,500 pounds per square foot. A lateral sliding resistance of 130 psf may also be considered between the bottom of the footing and soils. The lateral sliding resistance may be added to the allowable lateral bearing value provided that in no case the total lateral resistance exceed one -half the dead load. 2. Earth Pressures The following earth pressures may be used considering on -site sandy deposits (Soil Type 3) for preliminary design estimates only and need to be re- evaluated when the characteristics of the backfill soils have been specifically determined. Revised recommendations should be anticipated. a) Design soil wet density = 118.8 pcf. b) Design soil angle of internal friction = 38 degrees. c) Design active soil pressure = 29 pcf (EFP), level backfill, cantilever, unrestrained walls. d) Design active soil pressure = 42 pcf (EFP), 2:1 sloping backfill, cantilever. unrestrained walls e) Design at -rest soil pressure = 46 pcf (EFP), non - yielding, restrained walls. f) Design passive soil pressure = 400 pcf (EFP), level surface at the toe. g) Design coefficient of friction for concrete on soil = 0.40. h) Allowable foundation pressure = 1500 psf. Notes: Because large movements must take place before maximum passive resistance can be developed. a minimum safety factor of two should be considered for sliding stability. VINJE B MIDDLETON ENGINEERINQ, INC. 2450 Vineyard Aa ue, 1102, Escondido, CaWmia 920294229 • Phone (760) 743 -1214 • 1" (760) 7390343 SOIL=MQ PERC TEST SOIL 1NV SfIQAT10NS QEOTECNNICAL INVESTIQATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 18 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27. 1997 ' When combining passive pressure and frictional resistance, the passive component should be reduced by one - third. ' The allowable foundation pressure provided herein was determined for footings having a minimum width of 12 inches embedded a minimum depth of 12 inches into the certified fill. This value may be increased per Uniform Building Code for additional widths and depths for import soils and depth only for on -site soils if needed (Table 18 -1 -A, Footnote 2). F. Pavement Design Specific pavement designs can best be provided at the completion of rough grading based on R -Value tests of the actual finish subgrade soils, however, the following structural sections may be considered for cost estimating purposes only in case of non - expansive sandy subgrade soils. 1 A minimum section of 3 inches asphalt on 6 inches of Caltrans Class II base may be used. Base materials should be compacted to a minimum of 95% of the maximum dry density. 2. Subgrade soils beneath the asphalt roadway, parking and driveways should be compacted to a minimum of 95% of the corresponding maximum dry density within the upper 1 foot. Sub and base grade soils should be tested for proper moisture and minimum 95% compaction levels and approved by the project geotechnical consultant prior to the placement of the base or asphalt layers. G. General Recommendations 1. The minimum foundation design and steel reinforcement provided herein is based on soil characteristics only and is not intended to be in lieu of reinforcement necessary for structural considerations. All recommendations should be evaluated and confirmed by the project architect /structural engineer. 2. Footings located on or adjacent to the top of slopes should be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet or one -third of the slope height, whichever is greater (need not exceed 40 feet maximum) between the bottom edge of the footing and face of slope. The specified set back requirements applies to all improvements and structures including fences. concrete walk ways, etc. 3. Expansive clayey soils should not be used for backfilling of any retaining structure. All retaining walls should be provided with a 1 1 wedge of granular, compacted backfill measured from the base of the wall footing to the finished VIN3E B MIDDLETON ENGINEERING, INC. 1450 Vineyusd Aoenue, 1102, Escondido. Cali forma 92029 -1229 • Phone (760) 743 -1214 • I= (760) 739-0343 SOIL TESTING PERC TEST SOIL INV'ESlIGATIONS GEOTECMNICAL INVESTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 19 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 surface Retaining walls should be provided with a back drainage in general accordance with the attached Plate 20. 4. All underground utility trenches should be compacted to a minimum of 90% of the maximum dry density of the soil unless otherwise specified by the respective agencies. Care should be taken not to crush the utilities or pipes during the compaction of the soil. Non - expansive, granular backfill soils should be used. 5. Site drainage over the finished pad surface should flow away from structures onto the street in a positive manner. Care should be taken during the construction, improvement, and fine grading phases not to disrupt the designed drainage patterns. Rooflines of the buildings should be provided with roof gutters. Roof water should be collected and directed away from the building and structures to a suitable location. Considerations should be given by the project architect to adequately damp proofing /water proofing the basement walls/foundations and provide the planter areas adjacent to the foundations with an impermeable liner and a subdrainage system. 6. Final grading and foundation plans should reflect preliminary recommendations given in this report and should be reviewed by this office prior to grading. More specific recommendations should be provided when final grading and architectural /structural drawings are available. 7. All foundation trenches should be inspected to assure adequate footing embedment and confirm competent bearing soils. Foundation and slab reinforcements should also be inspected and approved by the project geotechnical consultant. 8. The amount of shrinkage and related cracks that occurs in the concrete slab -on- grades, flatworks and driveways depends on many factors, the most important of which is the amount of water in a concrete mix. The purpose of the slab reinforcement is to keep normal concrete shrinkage cracks closed tightly. The amount of concrete shrinkage can be minimized by reducing the amount of water in the mix. To keep shrinkage to a minimum, the following should be considered. ' Use the stiffest mix that can be handled and consolidated satisfactorily Use the largest maximum size of aggregate that is practical, (for example, concrete made with three - eights inch maximum size aggregate usually requires about 40 Ibs more (nearly 5 gal.) water per cubic yard than concrete with one inch aggregate). Cure the concrete as long as practical. VIN1E B MIDDLETON ENGINEERING, INC. 2450 Vineyard Aoenue, •102, Eerondido, California 92029.1229 • Phone (760) 743.1214 • Fa: (760) 739-0343 SOILTESTING PERC TEST SOIL INVESTIGATIONS GEOTECHNICAL MVFSTIGATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 20 DOUBLE LL RANCH ROAD OLIVENHAIN MAY 27, 1997 The amount of slab reinforcement provided for conventional slab -on -grade construction considers that good quality concrete materials, proportioning, craftsmanship, and control tests where appropriate and applicable are provided. 9 A preconstruction meeting between representatives of this office and the property owner or planner, as well as the grading contractor /builder, is recommended in order to discuss grading /construction details associated with site development. Vlll. LIMITATIONS The conclusions and recommendations provided herein have been based on all available data obtained from research and review of pertinent geotechnical reports and plans, current exploratory excavations as well as our experience with the soils and formational materials located in the general area. The materials encountered on the project site and utilized in our laboratory testing are believed representative of the total area: however, earth materials may vary in characteristics between excavations. Of necessity we must assume a certain degree of continuity between exploratory excavations and /or natural exposures. It is necessary, therefore, that all observations. conclusions, and recommendations be verified during the grading operation. In the event discrepancies are noted, we should be contacted immediately so that an inspection can be made and additional recommendations issued if required. The recommendations made in this report are applicable to the site at the time this report was prepared. It is the responsibility of the owner /developer to insure that these recommendations are carried out in the field. It is almost impossible to predict with certainty the future performance of a property. The future behavior of the site is also dependent on numerous unpredictable variables, such as earthquakes, rainfall, and on -site drainage patterns. The firm of VINJE & MIDDLETON ENGINEERING, INC. shall not be held responsible for changes to the physical conditions of the property such as addition of fill soils, added cut slopes, or changing drainage patterns which occur without our inspection or control. The property owner(s) should be aware of the development of cracks in all concrete surfaces such as floor slabs and exterior stucco associated with normal concrete shrinkage during the curing process. These features depend chiefly upon the condition of concrete and weather conditions at the time of construction and do not reflect detrimental ground movement. Hairline stucco cracks will often develop at window /door corners. and floor VINIE B MIDDLETON ENGINEERING, INC. 2450 Vin ,d Avenue, #102, Es,ondido, CaI4o is 91029.1229 • Ph. (760) 743.1214 • F= (760) 739-0343 SOIL TEa G PERC TEST SOIL INVESTIQATIONS GEOTECNNICAL INVESTIQATIONS PRELIMINARY GEOTECHNICAL INVESTIGATION PAGE 21 DOUBLE LL RANCH ROAD, OLIVENHAIN MAY 27. 1997 surface cracks up to A -inch wide in 20 feet may develop as a result of normal concrete shrinkage (according to the American Concrete Institute). This report should be considered valid for a period of one year and is subject to review by our firm following that time. If significant modifications are made to your tentative development plan, especially with respect to the height and location of cut and fill slopes, this report must be presented to us for review and possible revision. Vinje & Middleton Engineering, Inc. warrants that this report has been prepared within the limits prescribed by our client with the usual thoroughness and competence of the engineering profession. No other warranty or representation, either expressed or implied, is included or intended. Once again, should any questions arise concerning this report, please do not hesitate to contact this office. Reference to our Job #97 -145 -V will help to expedite our response to your inquiries. We appreciate this opportunity to be of service to you. Dennis Middleton CEG #980 Mehdi Shariat RCE #46174 RMV /DM /MS /mmd Distribution: Addressee (5) Attachments: Plates 1 -20 sms kvpdocsl97 -14Sv. pgi mmd\prehml97.145 -v. pgi 2 r No. 863 r„ a * c� Exp. 12-31-97Q y, SNAED Geo o CEG 980 z * CERTIFIED ENGNEERING \F FoF cnU`o No. 4E 174 1 EXP. 12-31-98 k VINIE B MIDDLETON ENGINEERING, INC. 2450 Vineyard Avenue, 0102, Escondido, California 92029 -1229 • Phone (760) 743 -1214 • Fax (760) 739 -0343 SOIL TESTING PERC TEST SOIL MrF_STRGATIONS GEOTECHNICAL INVESTIGATIONS Date: 4/22/97 Logged by: DM DEPTH Irtl SAMPLE T -1 MOISTURE (%1 DRY DENSITY (W) RELATIVE COMPACTION I%I DESCRIPTION TOPSOIL: ■ Clay. Olive -brown color. Slightly sandy. Moist, stiff to hard. Very expansive. BEDROCK (Td): 5 - ■ BEDROCK (Td): Claystone. Olive green color to rust - brown. Highly 5 - fractured and very weathered. Soft to blocky. ■ Indistinct structure. At 5', approximate attitude on cream - colored siltstone lens: N40E /10NW. End trench at 7'. 10- End trench at 7'. - 15- Date: 4/22/97 Logged by: DM DEPTH lel SAMPLE T -2 MOISTURE I' /.I DRY DENSITY Ip<<) RELATIVE COMPACTION IZI DESCRIPTION TOPSOIL: Clay Brown color. Slightly moist and hard near surface, moist and stiff below. Expansive. BEDROCK (Td): 5 - Claystone. Grey with rust -brown stains. Weathered soft. ■ Indistinct structure. End trench at 7'. -10- -15- VINJE & MIDDLETON ENGINEERING, INC TEST TRENCH LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Development Planning Consultants International, Inc. PROJECT NO. 97 -145 -V PLATE 2 Office 760 - 743 -1214 Fax 760 - 739 -0343 ♦ Sand Cone Test ■ Bulk Sample ❑ Chunk Sample O Driven Rings Date: 4122/97 Logged by: DM DEPTH SAMPLE T -3 MOISTURE DRY DENSITY (P«) RELATIVE COMPACTION (%) DESCRIPTION 5 ALLUVIUM (Qal): Silty sand. Tan color. Slightly moist, loose. Silty clay with rock fragments. Moist, loose. BEDROCK (Td): Claystone. Olive -grey. Fractured and weathered soft. Massive. - - 10 - End trench at 12'. -15- Date: 4/22/97 Logged by: DM DEPTH (nl SAMPLE T -4 MOISTURE ( %) DRY DENSITY (P«) RELATIVE COMPACTION 1%) DESCRIPTION TOPSOIL: Clayey to silty fine sand. Brown. Dry and hard to moist and stiff. BEDROCK Tt): 5 - Sandstone. Tan color. Fine to medium grained. Weathered friable to moderately well cemented and blocky along horizontal parting. Moist. Indistinct bedding. Sandstone transitions to Claystone (Td) below elevation 10- 272'. Olive grey color. Weathered and fractured to popcorn texture. Moist. End tren ch at deep. Extend down ridge . -15 VINJE & MIDDLETON ENGINEERING, INC TEST TRENCH LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Development Planning Consultants International, Inc. PROJECT NO. 97 -145 -V PLATE 3 Office 760 - 743 -1214 Fax 760 - 739 -0343 V Sand Cone Test ■ Bulk Sample ❑ Chunk Sample 0 Driven Rings Date: 4/22/97 Logged by: DM Oeairr Irtl SAMPLE T -5 MOISTURE IXI DRY D NSITY IpCrl RELATIVE COM ACTION I %) DESCRIPTION TOPSOIL 5 - ■ Sandy clay. Dark brown. Slightly moist, hard. -10- -15- End trench at 6'. VINJE & MIDDLETON ENGINEERING, INC 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Office 760 -743 -1214 Fax 760 - 739 -0343 TEST TRENCH LOGS BEDROCK Tt): - V Sand Cone Test ■ Bulk Sample ❑ Chunk Sample 0 Driven Rings 5--Q Sandstone. Tan to brown color. Fine grained. 21.8 82.8 74.4 - Weathered. Friable. Upper sandstone transitions to Claystone (Td) at - approximate elevation of 295'. Olive green color, - - weathered soft. -10- End trench at 5'. L15-- Date: 4/22/97 Logged by: DM DEPTH Ittl SAMPLE T -6 MOISTURE I %) DRY DENSITY IPCO RELATIVE COMPACTION 1%1 DESCRIPTION TOPSOIL: Clay Dark brown. Slightly moist, stiff to hard. 5 - ■ BEDROCK (Td): Claystone. Very sandy. Tan -green color. Weathered soft to friable. Massive. -10- -15- End trench at 6'. VINJE & MIDDLETON ENGINEERING, INC 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Office 760 -743 -1214 Fax 760 - 739 -0343 TEST TRENCH LOGS Development Planning Consultants International, Inc. PROJECT NO. 97 -145 -V PLATE 4 V Sand Cone Test ■ Bulk Sample ❑ Chunk Sample 0 Driven Rings Date: 4/22/97 Logged by: DM DEPTH MI SAMPLE T -7 MOISTURE I %) DRY DENSITY (PcfI RELATIVE COMPACTION N DESCRIPTION TOPSOIL: Clay. Dark brown. Moist, stiff to hard. 5 _10- ■ BEDROCK (Td): Claystone. Grey color with rust brown stains. Weathered to popcorn consistency. Massive. No apparent bedding. BEDROCK (Td)i Claystone. Grey color with rust -brown stains. Weathered soft in upper 2', stiff below massive. End trench at 5'. Date: 4/22/97 Logged by: DM DEPTH (tt) SAMPLE T -8 MOISTURE ( %j DRY DENSITY (Pd) RELATIVE COMPACTION (%) DESCRIPTION FILL (af): Silty sand with scattered bedrock fragments. Tan. Moist, loose. 5 10 - ALLUVIUM (Qal): Silty to clayey sand. Brown. Moist, loose to soft. From 6', color grades to pale brown. Remains soft. BEDROCK (Td)i Claystone. Grey color with rust -brown stains. Weathered soft in upper 2', stiff below massive. End trench at 13'. -15- VINJE & MIDDLETON ENGINEERING, INC 2450 Vineyard Avenue, Suite 102 Escondido, California 92029-1229 Office 760 - 743 -1214 Fax 760 - 739 -0343 TEST TRENCH LOGS Development Planning Consultants International, Inc. PROJECT NO. 97 -145 -V PLATE 5 V Sand Cone Test ■ Bulk Sample ❑ Chunk Sample O Driven Rings Date: 4/23/97 Logged by: DM DEPTH (nl SAMPLE T -9 MOISTURE IZ) DRY DENSITY (Pcf) RELATIVE COMPACTION (%1 DESCRIPTION ■ TOPSOIL: Sandy clay. Dark brown. Slightly moist, stiff to hard. Expansive. ST -1 ■J 17.7 106.7 95.9 BEDROCK (Td): 5 - ■J 11.0 119.0 992 - Sandstone. Tan color. Fine to medium grained. Friable to moderately well cemented. Massive. ST -3 color with rust stains. Weathered friable. ST -3 End trench at 7'. Upper contact oriented N5 /30W. -10- -15- Date: 4/23/97 Logged by: DM DEPTH (ft) SAMPLE T -10 MOISTURE 1 %I DRY DENSITY (Pcf) RELATIVE COMPACTION I %) DESCRIPTION ■ TOPSOIL: Clay Dark brown. Slightly moist. Hard. Expansive. ST -1 BEDROCK (Td): ■J 17.7 106.7 95.9 5 Claystone (west end of trench.) Olive -green color. White - carbonate throughout. Weathered soft. ST -2 Interbedded with sandstone, (east end of trench.) Tan color with rust stains. Weathered friable. ST -3 10- Upper contact oriented N5 /30W. End trench at 7'. -15- VINJE & MIDDLETON ENGINEERING, INC TEST TRENCH LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Office 760 - 743 -1214 Fax 760 - 739 -0343 Development Planning Consultants International, Inc. PROJECT NO. 97 -145 -V PLATE 6 ♦ Sand Cone Test ■ Bulk Sample J Chunk Sample O Driven Rings Date: 4/23/97 Logged by: DM DEPTH I "I SAMPLE T -11 MOISTURE I%) DRY DENSITY (P<rl RELATIVE COMPACTION I %) DESCRIPTION SAMPLE ALLUVIUM (Qal): DENSITY COMPACTION Ittl I°.I Silty sand. Pale brown color. Includes 20% - 30% large I %I DESCRIPTION TOPSOIL: cemented siltstone fragments (up to 1' diameter.) Loose. ■ Sandy clay. Dark brown. Slightly moist, hard. Grades to Slightly moist. -5- clay with white carbonate deposits. Moist, stiff. ST -1 5 - ■ BEDROCK (Td): BEDROCK (Td): Claystone. Pale grey with rust stains. Sandy. Weathered ❑ soft and popcorn texture. Massive. ST -3 Claystone. Blue -grey color. Weathered soft. 120.0 100+ End trench at 8'. Massive. ST -3 End trench at 8'. 10- -15- TEST TRENCH LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Development Planning Consultants International, Inc. Date: 4/23/97 Logged by: DM T-12 DRY RELATIVE DEPTH SAMPLE MOISTURE DENSITY COMPACTION Ittl I°.I (P0) I %I DESCRIPTION TOPSOIL: ■ Sandy clay. Dark brown. Slightly moist, hard. Grades to clay with white carbonate deposits. Moist, stiff. ST -1 5 - ■ BEDROCK (Td): Claystone. Pale grey with rust stains. Sandy. Weathered ❑ soft and popcorn texture. Massive. ST -3 13.3 120.0 100+ End trench at 8'. -10- -15- VINJE & MIDDLETON ENGINEERING, INC TEST TRENCH LOGS 2450 Vineyard Avenue, Suite 102 Escondido, California 92029 -1229 Development Planning Consultants International, Inc. Office 760 - 743 -1214 Fax 760 - 739 -0343 PROJECT NO. 97 -145 -V PLATE 7 ♦ Sand Cone Test ■ Bulk Sample ❑ Chunk Sample J Driven Rings LeEQ0 2g jog B -1 Plate 8 ~� a DESCRIPTION No ' =w ¢a Za o- �£o WLL a p- N 2 a TOPSOIL: CDark brown. Slightly moist, stiff. BEDROCK (Td): Sandstone /siltstone. Off -white to pale brown color. White carbonate deposits throughout. Weathered soft and loose. 5 Claystone. Olive -green color. Fractured and weathered to popcorn texture grading to more blocky below 5'. Massive. Gradational contact above. Sandstone. Tan to off -white color. Fine to medium grained. Weathered friable. Upper contact is gradational and nearly horizontal. 10 at 11', very hard, cemented sandstone slows drilling. End boring at 11'x. Bucket refused by hard rock. 15 20 25 30 sample Bulk Project Development Planning Consultants International, Inc. O Ring sample Number 97 -145 -V Date drilled 4/28/97 Logged by DM O SPT sample I _'i� L_J ?' },„(`If PY— At1OPT V Sand cone test , vrm, sumpie wiemou Vinje & Middleton 0 [�3or�owg aog B -2 Plate 9 w ¢ r s Wo a� i DESCRIPTION w � O N 0 � O 0 TOPSOIL: Clay. Dark brown. Moist, stiff to hard. BEDROCK (Td): Claystone. Pale green color. Some sand and gypsum deposit throughout. Massive Weathered soft. 5 O 20.6 98.4 88.3 from 8' - 9' marron colored stains. I0 from 13', grades sandy. 5 at 15', Sandstone bed. 6 inches thick. Friable. Ground water seepage. Upper contact is abrupt, oriented N70E /19NW. Claystone. Dark green. Fractured, moderately hard. Grades to slightly blocky. Massive. 20 Claystone /Siltstone. Pale green to pale brown color with maroon stains. Massive. Slightly hard and blocky. Gradational contact above. 25 30 from 31" drilling is slowed by harder silts tone /clays tone End boring at 32'. 0 Bulk sample Development Planning Consultants International, Inc. Project O Ring sample 97 -145 -V 4/28/97 DM Number Date drilled Logged by a SPT sample 2' hucket -aueer 2400 lb drive V Sand cone test Drill, sample method Vinje & Middleton C�or�awg dog B -3 Plate 10 _ a� J a DESCRIPTION w o y t �H� o aao w� f pWa ¢p' TOPSOIL• Clayey silt. Pale red - brown. Slightly moist, firm BEDROCK (Tt): Sandstone. Off -white color. Fine grained. Discontinuous rust - colored seams are nearly horizontal. Friable. 5 O 12.0 115.6 96.4 from 9'-12', brown zone. Consists of dark brown medium grained sand with hard, limey bed approximately 2" thick. Zone dips eastward approximately 5 degrees. Below 10 sandstone is tight and moderately well cemented. 15 at 20', attitude on series of parallel rust - colored 20 seams: N55E /IONW. at 24', brown zone. Consists of dark brown colored medium grained sand with cemented lenses. Very tight. Drilling is 25 slowed. End boring at 25'. 30 sample 0 Bulk Project Development Planning Consultants International, Inc. Ring sample Number 97 -145 -V 4/28/97 DM Date drilled Logged by O SPT sample Drill, sample method 2' bucket - auger, 2400 lb. drive. V Sand cone test Vinje & Middleton n n �,J(f OLI alJU y' �O�.1I C/ C B -4 Plate 11 = wLL J DESCRIPTION K Y �y� z = `ae 's ° D Q No O.r CZa W ¢oy UI � O •+ C TOPSOIL: Clayey silt. Pale red - brown. Slightly moist, firm. BEDROCK (Tt): Sandstone. Pale grey with rust stains. Fine to medium 5 grained. Cross - bedded. at 4', cross - bedding along thin rust colored seams EW /20N. On from 8' - 9'', zone of pale brown sand with hard, cemented 7.8 119.6 99.7 bed. Nearly horizontal. 10 13' - 15', similar zone of pale brown sand. 15 at 19', horizontal bedding along thin, rust - colored bed. 20 at 231, cross - bedding along series of rust - colored seam dips west. 25 Siltstone. Pale grey to rust brown. Upper contact is rust colored sandy silt with gypsum crystals. Dips northward 5 degrees. 30 from 30', grades more sandy. 35 BEDROCK (Td): Claystone. Olive green color. Massive. Fractured and block T. Upper contact is nearly horizontal and marked by thin rust sand zone. End boring at 38'. 40 Development Planning Consultants international, inc. 0 Bulk sample Project O Ring sample 97 -145 -V 4/29/97 DM Number Date drilled Lagged by O SPT sample n _: _ ,._J O, U t-o..nor ')Lnn lh. drive. W Qnnd rnnp t.-qt V111, CIMPLe 1116111V Vinje & Middleton �o�o�g jog B -5 Plate 12 a DESCRIPTION r '- LL WU > J`e NO _ p21 p u 0 TOPSOIL: Clay. Dark brown. Slightly moist, hard to stiff. BEDROCK (Td): Siltstone /Claystone. Pale green. Massive. Weathered moderately soft. Locally sandy. 5 10 Claystone. Olive green color with rust stains. Moderately hard and blocky. Massive. Upper contact is gradational. 11.9 116.3 100+ from 12', rock is locally sandy including 6" thick sandstone beds with nearly horizontal gradational contacts. 15 at 16', very hard, well- cemented sandstone. End boring at 17'. Drill bucket refused by hard rock. 20 25 30 sample 0 Bulk Project Development Planning Consultants International, Inc. 0 Ring sample Number 97 -145 -V Date drilled 4/29/97 Logged by DM O SPT sample M_Al _ — I- ,,,,,,,,,,a 2' bucket - auger, 2400 lb. drive V Sand cone test Vinje & Middleton Vinje & Middleton B -6 Plate 13 a DESCRIPTION WLL f ��o OZ6 W�- 0 ALLUVIUM (Qal): Brown sandy clay to clayey sand. Dry at the surface becomin moist with depth, loose to soft. 5 0 14.7 110.2 -- 7/,3 10 O9 /7A 14.8 112.8 -- 15 — BEDROCK (It): 3� Red brown siltstone /claystone to sandstone, dry to moist, 12.9 120.8 100+ /r0 very hard. 20 14 I Izj HS End boring at 21'x'. 25 30 Bulk sample Project Development Planning Consultants International, Inc. O Ring sample Number 97 -145 -V Date drilled 4/27/97 Logged by SMS O SPT sample Drill, sample method 6" diameter auger, 140 lb. drive V Sand cone test Vinje & Middleton GEOLOGIC CROSS - SECTIONS Plate 14 A R 3001 I Par. 1 —� Proposed Grades 250 Par. 2 , BEDROCK — T -2 A BEDROCK Td :AiCUV1UM 200 g i B-3 Par. 4 Proposed Grades Par. 3 300 % $ -5 Tt _ _... BEDROCK - - 8, -_ REPORTED STABILIZATION FILL Td (LIMITS ARE UNKNOWN) 250 ... - -... ., .. ___. _._ _. -�. - - T -11 FILL /ALLUVIUM 230 BEDROCK = '~ .......... ro.l) 200 Scale. 1"=60' - — I — - - - - - - - ------------- ---------- J. ED (D 10 % Las Anbsli� NZ.." 0 • r 'Ile a 4 0 ww. % 0 D S It E? COMM di S an eg 0 0 30 20 0 0 30 MILES FAULT - EPICENTER MAP SAN DIEGO COUNTY REGION INDICATED EARTHQUAKE EVENTS THROUGH 75 YEAR PERIOD (1900-1974) Map data is compiled from various sources including California Division of Mines and Geology, California Institude of Technology and the National Oceanic and Atmospheric Administration. Map is reproduced from California Division of Mines and Geology, "Earthquake Epicenter Map of California; Map Sheet 39." Earthquake Magnitude 4.0 TO 4.9 5.0 TO 5.9 .......... - 6.0 TO 6.9 PROJECT- Double LL Ranch Rd. O.......... 70 TO 7.9 Olivenhain Fault PLATE NO. 15 TYPICAL PAD CONSTRUCTION DETAILS Plate 16 `01'91ci` e ?4l �SU \C� Fp , P SURFACE L LL KEY V \ Do I h drain —2 2 FILL CAP; Width Construction Notes 1. Drains are 4" diameter perforated pipe (Schedule 40 or / SDR -35) 2. Use 4 cu. ft. per foot of 3 /4-inch rock wrapped in Mirafi 140N filter fabric 4 cu. ft. of Caltrans Class 2 filter FILL KEY / materials for subdrain construction. Delete filter fabric if Caltrans Class 2 is used. I / 3. Subdrains should be situated to allow suitable outlet. 4. Provide 4 -inch diameter non - perforated solid pipe outlet laterals — at 100 feet maximum O.C. horizontally. I I 5. See geotechnical report for more details. F'—to' min. 6. All stabilization fills, recommended deepened fill keys, and subdrains should be shown on the final grading plans and reviewed and approved by the project soil engineer. project 1:1 line from top of slope to outside edge of key able material materials 2' min. key depth existing ground surface -T -J) AND BENCHING DETAILS (Typical — no scale) existing ground / surface �� finish cut Dad finis slope / I compacted fill / \ width min blench '2; min. Ri —!—)I =:: = T pad overexcavation and recompaction per projecL geotechnical engineer th competent bedrock or fir native ground per project geotechnical engineer Side Hill Stability Fill Slope finish pad finish slope compacted fill f z ne ope ��}1 one equipment - J� = width minimum ` remove unsuitable --III bench materials 1 min. 2' min. key width key depth \ competent bedrock or firm native ground per project geotechnical engineer Fill Slope Note: Key and benching details shown herein are subject to revisions by the project geotechnical engineer based upon actual site conditions. Back drains may also be necessary as determined by the project geotechnical consultant. Plate # 17 existing ground surface KEY AND BENCHING DETAILS (Typical - no scale) finish slope finish pad remove unsuitable compacted films/ materials 1I1 L% min, iequi menr widt min 4 min, 15' min '1 depth key width .,� cut slope )I = (to be excavated prior to fill placement) Fill- Over -Cut S1 existing ground surface remove unsuitable materials project 1:1 line from toe of slope to competent materials 2' min.' 15' min. key depth key width I 11 iMil competent bedrock or firm native ground per project geotechnical consultant finish pad cut slope (to be excavated prior to fill placement) bench per project geotechnical engineer in the field - also, see geotechnical report competent bedrock or firm j— native ground per project geotechnical consultant Cut - Over -Fill Slope Note: Kev and benching details shown herein are subject to revision by the project geotechnical engineer based upon actual site conditions. Back drains may also be necessary as determined by the project geotechnical consultant. Plate # 18 ISOLATION JOINTS AND RE- ENTRANT CORNER REINFORCEMENT (a) Typical - no scale CMON JOINTS RACTION JOIN- (C) (b) RE-ENTRANT C( REINFORCEMENT NO. 4 BARS PL BELOW TOP OF NOTES: ENTRANT NER CRACK 1. Isolation joints around the columns should be either circular as shown in (a) or diamond shaped as shown in (b). If no isolation joints are used around columns, or if the corners of the isolation joints do not meet the contraction joints, radial cracking as shown in (c)may occur (reference ACI). 2. In order to control cracking at the re- entrant corners ( ±270° corners), provide reinforcement as shown in (c). 3. Re- entrant corner reinforcement shown herein is provided as a general guideline only and is subject to verification and changes by the project architect and /or structural engineer based upon slab geometry, location, and other engineering and construction factors. VINJE & MIDDLETON ENGINEERING, INC. PLATE 19 TYPICAL RETAINING WALL DRAIN DETAIL Waterproofing <M��a Perforated drain pipe drainage — Granular, non - expansive backfill. Compacted. Filter Material. Crushed rock (wrapped in filter fabric) or Class 2 Permeable Material l t' (see specifications below) –71j:�l Competent, approved soils or bedrock CONSTRUCTION SPECIFICATIONS: SPECIFICATIONS FOR CALTRANS CLASS 2 PERMEABLE MATERIAL U.S. STANDARD SIEVE SIZE %PASSING 1" 100 314 90-100 3/8 40.100 No. 4 25-40 No.8 18 -33 No. 30 5-15 No. 50 0.7 No 200 0.3 Sand Equivalent > 75 1. Provide granular, non - expansive backfill soil in 1:1 gradient wedge behind wall. Compact backfill to minimum 90% of laboratory standard. 2. Provide back drainage for wall to prevent build -up of hydrostatic pressures. Use drainage openings along base of wall or back drain system as outlined below. 3. Backdrain should consist of 4" diameter PVC pipe (Schedule 40 or equivalent) with perforations down. Drain to suitable outlet at minimum 1 %. Provide' /: - V/2" crushed gravel filler wrapped in filter fabric (Mirafi 140N or equivalent). Delete filter fabric wrap if Caltrans Class 2 permeable material is used. Compact Class 2 material to minimum 90% of laboratory standard. 4. Seal back of wall with waterproofing in accordance with architect's specifications. 5. Provide positive drainage to disallow ponding of water above wall. Lined drainage ditch to minimum 2% flow away from wall is recommended. Use t'/: cubic foot per foot with granular backfill soil and 4 cubic foot per foot if expansive backfill soil is used. VINJE & MIDDLETON ENGINEERING, INC. PLATE 20