2014-12126 I (Plans)GENERALNOTES 1. A PERMIT SHALL BE OBTAINED FROM THE CITY DEPARTMENT OF PUBLIC WORKS FOR ANY WORK WITHIN THE STREET RIGHT -OF -WAY. 2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH THE CITY OF ENCINITAS STANDARDS AND AS APPROVED BY THE CITY ENGINEER. 3. APPROVAL OF THESE IMPROVEMENTS PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY. 4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL BE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER AND PAVING. 5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS TO THE BEST OF OUR KNOWLEDGE, THERE ARE NOT OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER, THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING FACILITY SHOWN HEREON AND ANY OTHER, WHICH IS NOT OF RECORD, OR NOT SHOWN ON THESE PLANS. 6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE DONE SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. CONTRACTOR WILL MAKE EXPLORATORY EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES. 7. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS AND ELECTRIC COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES. 8. THE CONTRACTOR SHALL NOTIFY THE PACIFIC TELEPHONE COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES. NOTICE: ALL TELEPHONE SERVICES WITHIN THIS PROJECT BOUNDARY ARE "UNDERGROUND INSTALLATIONS." FOR LOCATION OF CABLES AND APPURTENANCES CONTACT THE PACIFIC TELEPHONE COMPANY. TELEPHONE: 1- 800 -422 -4133 9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTACT THE UTILITY AGENCIES, ADVISE THEM OF THE PROPOSED IMPROVEMENTS, AND BEAR THE COST OF RELOCATIONS, IF NEEDED. 10. ALL TELEVISION SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND INSTALLATIONS." FOR LOCATION OF CABLES AND APPURTANCES CONTACT APPROPRIATE COMPANY. 11. THE CONTRACTOR SHALL REQUEST A PRE - CONSTRUCTION MEETING FROM THE CITY ENGINEER'S OFFICE AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE FOR SUCH A MEETING. PHONE NO. 633 -2770 12. PRIVATE ROAD IMPROVEMENTS SHOWN HEREON ARE FOR INFORMATION ONLY. CITY OFFICIALS SIGNATURE HEREON DOES NOT CONSTITUTE APPROVAL OR RESPONSIBILITY OF ANY KIND FOR THE DESIGN OR CONSTRUCTION OF THESE PRIVATE IMPROVEMENTS. (IF APPLICABLE) NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND INSTALLATIONS." FOR LOCATION OF ELECTRICAL CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE SAN DIEGO GAS & ELECTRIC COMPANY. TELEPHONE: 1- 800 - 422 -4133 THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS. THE ENGINEER AGREES THAT ANY PLAN CHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN, AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE ENGINEER. BY (ti!zf DATE `l -`tA- k RCE NO. 6 - (ppgS% 12 -31 -I$ COMPANY GAC ENGINEERING AND LAND SURVEYING ADDRESS 41993 VIA RENATE TEMECULA CA 92591 PHONE 760 - 594 -4889 ENGINEER'S JOB NO SEWER NOTES: CARDIFF SANITATION DISTRICT ALL WORK SHALL BE DONE IF ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION "GREENBOOK ", (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, (ADOPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE), THE SAN DIEGO REGIONAL STANDARD DRAWINGS (LATEST EDITION) AND THE FOLLOWING SPECIAL PROVISIONS: 1. TRENCH WIDTH SHALL BE PER SDRSD NO. SP -02 UNLESS OTHERWISE NOTED. MINIMUM PIPE SEPARATION PER WAS WI -01, 02, & 03. 2. PIPE AND BEDDING CONDITIONS: (A)ALL PIPE SHALL HAVE 4" MINIMUM OF %'I CRUSHED ROCK BENEATH THE PIPE. (B) V.C.P. PIPE BEDDING FROM BOTTOM OF PIPE TO 12" MINIMUM ABOVE THE PIPE SHALL BE SAND, GRAVEL, CRUSHED AGGREGATE, NATIVE FREE - DRAINING GRANDULAR MATERIAL HAVING A SAND EQUIVALENT OR 30 OR BETTER. (C) P.V.C. AND A.B.S. SOLID WALL PIPE BEDDING FROM BOTTOM OF PIPE TO 12" MINIMUM ABOVE THE PIPE SHALL BE %" CRUSHED ROCK. A.B.S. SOLID WALL PIPE MAY BE USED ONLY WHERE PIPE INVERT GRADES ARE 1 % OR GREATER. 3. AFTER COMPLETION OF PIPE LAYING, ALL MAIN LINE SEWERS, SEWER SERVICE LATERALS AND STRUCTURES SHALL BE TESTED IN THE PRESENCE OF THE INSPECTOR. AIR PRESSURE TEST SHALL BE USED UNLESS OTHERWISE DIRECTED BY THE CITY ENGINEER. 4. THE CONSTRUCTION OF P.C.C. SEWER MANHOLE SHALL BE PER SDRSD NO. SM -02. POURED IN PLACE MANHOLE BASES SHALL BE A MONOLITHIC POUR FINISHED COMPLETE AT TIME OF POUR. PRECAST MANHOLE BASES ARE ACCEPTABLE FOR USE WITH 8 -INCH COLLECTOR SYSTEMS WITH CITY ENGINEER'S APPROVAL. 5. THE CONSTRUCITON OF 4 -INCH SEWER LATERAL PER SDRSD NO'S SS -01 AND SS -02. LATERALS SHALL NOT DISCHARGE DIRECTLY INTO MANHOLE. 6. THE CONSTRUCTION OF CONCRETE CUT -OFF WALLS SHALL BE CONSTRUCTED AS PER SDRSD NO. SP -07. 7. ALL MAINS AND LATERALS SHALL BE A MINIMUM OF 42- INCHES BELOW THE FINISHED GRADE. 8. THE FINAL LOCATION AND ELEVATION OF SEWER AND WATER MAINS AND LATERALS AND MATERIALS AS SPECIFIED IN THE MOST REC SHALL BE SHOWN ON ORIGINAL AS -BUILT PLP NS PRIOR TO ACCEPTANCE OF WORK. 9. FOR SEWER LATERAL TABLE, SEE SHEET 2. ENDMENTS ADOPTED PRIOR TO THE 10. "AS BUILT" DRAWINGS MUST BE SUBMITTED F RIOR TO FINAL ACCEPTANCE OF THE IMES. WORK. ALS (SHOP DRAWINGS 6 SETS) AS 11. ALL DESIGN CHANGES OF SEWER MAINS SHAH L BE APPROVED BY A CONSTRUCTION INSPECTOR. CHANGE PRIOR TO ACCEPTANCE FOR PUBLIC USE. 12. FILL AREAS MUST BE COMPACTED TO 90% PRIOR TO PIPE INSTALLATION. 13. THE CONTRACTOR SHALL NOTIFY THE CITY'S FIELD OPERATIONS DIVISION 48 HOURS IN 4. CONTRACTOR SHALL COORDINATE WITH DIST ADVANCE OF BEGINNING WORK TO ARRANGE FOR PRE -CON AND INSPECTION OF NO SHUTDOWNS WILL BE SCHEDULED ON A PROJECT. PHONE NO. 760 - 633 -2770. 14. CONTRACTOR SHALL OBTAIN A PERMIT FRON THE CITY'S ENGINEERING SERVICES SHALL BE SUBMITTED TO THE DEPARTMENT FOR ANY EXCAVATION WITHIN EXISTING CITY RIGHTS -OF -WAY. 15. THE APPLICANT SHALL WARRANTY THE PUBL C SEWER FOR ONE YEAR FOLLOWING THE 48 HOURS PRIOR TO THE APPROVAL OF THE AS- BUILTS. OF THE PROJECT. 16. CONTRACTOR SHALL FURNISH AND INSTALL, PER SDRSD SP -01, THE APPROPRIATE IOR TO CONSTRUCTION. THIS CALL WILL BE BURIED UTILITY WARNING AND IDENTIFICATI TAPE ABOVE ALL PUBLIC SEWER LINES, PUBLIC RIGHT OF WAY. ( DIG ALERT PHONE: 800-227-2600). AND PORTIONS OF SEWER LATERALS LOCATED WITHIN PUBLIC RIGHT -OF -WAY OR ROJECT CONSTRUCTION, IE. LINE EASEMENTS. CONNECTIONS SHALL BE FIELD VERIFIED 17. THE DEVELOPER SHALL PROVIDE EASEMENT6 AND ACCESS ROADS OVER PUBLIC LL PER THE STANDARD SPECIFICATIONS SEWERS TO THE SATISFACTION OF THE CITYIENGINEER. THESE ARE TO BE SHOWN ON WATER LINES INCLUDING WATER LATERALS LOCATED THIS PLAN. 10. WHERE ELEVATIONS AND GRADES ARE NOT I 18, WASTEWATER DISCHARGE PERMITS AND PLUMBING PERMITS ARE REQUIRED PRIOR TO GRADDE OF THE STREET. CONNECTION TO THE SANITARY SEWER SYS EM. 19. ALL NEW SEWER MAINS SHALL BE INSPECTED BY CLOSED CIRCUIT TELEVISION AFTER (CURVING) OF PIPE SHALL BE PERMITTED. COMPLETION OF TRENCHING BACKFILL AND I INISHED GRADING BUT PRIOR TO AT ALL HIGH POINTS AND BLOW -OFFS AT PLACEMENT OF PAVEMENT OR PERMANENT RENCH RESURFACING. CONTRACTOR BLOWOFFS WITHIN METER BOXAND LOCATE BEHIND SHALL PROVIDE FOR TELEVISION INSPECTIO J. (SEE 500- 1.1.5) 20. SEWER MANHOLE LINING: HIGH OR LOW POINTS, AS APPROVED BY THE DISTRICT REPRESENTATIVE. (A) NEW MANHOLES WITH 8 -10" DIAMETEF SEWER MAINS: THE INSIDE OF THE SEWER O EACH LOT. METER TO BE LOCATED MANHOLES SHALL BE COATED WITH AN EP XY PROTECTIVE LINING SYSTEM PER EXISTING CURB OR IMPRINTED IN NEW CURB AT SECTION 500 -2.7 OF THE GREENBOOK. A 14. METER BOXES SHALL NOT BE PLACED WITHII I DRIVEWAYS OR SIDEWALKS WITHOUT THE (B) NEW MANHOLES WITH 12" DIAMETER ND GREATER SEWER MAINS: THE INSIDE 15. ALL WATER SERVICES FOR IRRIGATION, MUL OF THE SEWER MANHOLES SHALL BE PRO lIDED WITH INTEGRALLY LOCKING PVC ALL HAVE APPROVED BACKFLOW LINING PER SECTION 500 -2.5 OF THE GREE 4BOOK. 16. CONTRACTOR SHALL TIE OFF ALL VALVE LO (C) EXISTING MANHOLES: ALL EXISTING IV NNHOLES WITH NEW CONNECTIONS SHALL OF VALVES. BE INSPECTED AND REPAIRED, AS NEEDED, WITH THE LINING SYSTEM THAT MATCHES TEE WHENEVER POSSIBLE. THE EXISTING LINING FOR THAT MANHOLE; FOR MANHOLES WITHOUT ANY EXISTING FIRE DISTRICT AND MEETING THE LINING, THE INSIDE OF THE SEWER MANHOLES SHALL BE COATED WITH AN EPDXY THE FIRE DISTRICT. PROTECTIVE LINING SYSTEM PER SECTIO 500 -2.7 OF THE GREENBOOK. M SHALL BE APPROVED BY THE DISTRICT EXCEPTIONS OR VARIATIONS TO THESE MAN IDLE LINING REQUIREMENTS MAY BE 20. THE WATER SYSTEM SHALL BE PRESSURE TESTED CONSIDERED ON A SPECIFIC CASE -BY -CASE 3ASIS BY THE CITY ENGINEER. 21. NO ADDITIONAL LATERALS SHALL BE PERMIT rED WITHOUT PAYING SEWER CAPACITY AND APPURTENANCES. FEES, PROCESSING A CONSTRUCTION CHANGE, AND JOINING THE SEWER REIMBURSEMENT DISTRICT. IF CREATED. 1. POTABLE WATER WORKS SHALL BE CONSTRUC TED IN ACCORDANCE WITH THE DETAILS AND MATERIALS AS SPECIFIED IN THE MOST REC ENT EDITION OF THE OLIVNHAIN MUNICIPAL WATER DISTRICT STANDARD SPECIFICATIONS A' D DRAWINGS FOR THE CONSTRUCTION OF WATERMAINS AND FACILITIES. INCLUDING ALL A' ENDMENTS ADOPTED PRIOR TO THE DISTRICT APPROVAL DATE ON THESE PLANS. CO JTRACTOR SHALL HAVE A COPY OF THE STANDARD SPECIFICATIONS ON THE JOB AT ALL IMES. 2. THE SUBMISSION AND REVIEW OF ALL SUBMIT ALS (SHOP DRAWINGS 6 SETS) AS REQUIRED BY THE STANDARD SPECIFICATIONS RE TO BE ACCOMPLISHED PRIOR TO THE PRE- CONSTRUCTION MEETING WITH THE DISTRICTS INSPECTOR. 3. UNLESS OTHERWISE NOTED, CONNECTIONS TO EXISTING MAINS SHALL BE MADE DRY. THE TIME AND DURATION OF THE SHUTDOWNS OF E ISTING MAINS SHALL BE SUBJECTTO APPOROVAL BY THE DISTRICT. DISTRICT SHALL BE NOTIFIED TWO WEEKS MINIMUM IN ADVANCE OF ANY SHUTDOWN. 4. CONTRACTOR SHALL COORDINATE WITH DIST ICT ALL ARRANGMENTS FOR HIGH - LINING TEMPORARY SERVICES PRIOR TO SHUTDOWNS. NO SHUTDOWNS WILL BE SCHEDULED ON A MONDAY OR FRIDAY. 5. CONTRACTOR SHALL REVIEW ALL PROPOSED TRENCH WORK WITH CALL/OSHA. A COPY OF EXEMPTION LETTER OR TRENCHING PERMIT. IF REQUIRED, SHALL BE SUBMITTED TO THE DISTRICT PRIOR TO CONSTRUCTION. 6. NO WORK MAY BEGIN WITHOUT DIRECTION OF THE DISTRICT'S INSPECTOR. CONTRACTOR SHALL NOTIFY THE DISTRICTS INSPECTION DEPARTMENT 48 HOURS PRIOR TO THE BEGINNING OF WORK TO ARRANGE FOR INSPECTION OF THE PROJECT. 7. THE CONTRACTOR MUST CALL DIG ALERT OF SOUTHERN CALIFORNIA" TO HAVE UNDERGROUND SERVICE UTILITIES LOCATED PF IOR TO CONSTRUCTION. THIS CALL WILL BE MADE AT LEAST 48 HOURS IN ADVANCE PRIOR TO ANY WORK BEING PERFORMED IN THE PUBLIC RIGHT OF WAY. ( DIG ALERT PHONE: 800-227-2600). 8. ALL EXISTING FACILITIES WHICH MAY AFFECT ROJECT CONSTRUCTION, IE. LINE CROSSINGS, LINE PARALLELING, OR PROPOSED CONNECTIONS SHALL BE FIELD VERIFIED BEFORE ANY CONSTRUCTION BEGINS. 9. THE CONTRACTOR SHALL FURNISH AND INSTP LL PER THE STANDARD SPECIFICATIONS THE APPROPRIATE BURIED UTILITY AND WARNIN G IDENTIFICATION TAPE ABOVE ALL PUBLIC WATER LINES INCLUDING WATER LATERALS LOCATED IN THE PUBLIC RIGHT OF WAY. 10. WHERE ELEVATIONS AND GRADES ARE NOT I iHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE ELEVATION OF THE PIPE PROFILE IS 48- 'INCHES BELOW CENTERLINE OF FINISH GRADDE OF THE STREET. 11. ALL DEFLECTIONS (HORIZONTAL AND VERTIC L) SHALL BE MADE BY USE OF JOINT COUPLINGS WITH 4 IN MAXIMUM DELECTION PEF COUPLING (21N PER JOINT). NO BENDING, (CURVING) OF PIPE SHALL BE PERMITTED. 12. MANUAL AIR RELEASES SHALL BE INSTALLED AT ALL HIGH POINTS AND BLOW -OFFS AT ALL LOW POINTS IN THE WATER MAIN PROFILE. PLACE MANUAL AIR RELEASES AND BLOWOFFS WITHIN METER BOXAND LOCATE BEHIND CURB UNLESS OTHERWISE APPROVED BY DISTRICT REPRESENTATIVE. FIRE HYDRANTS MAY BE USED IN LIEU OF A MANUAL AIR RELEASE OR BLOW OFF WHEN LOCATED AT OR 14EAR HIGH OR LOW POINTS, AS APPROVED BY THE DISTRICT REPRESENTATIVE. 13. INSTALL A MINIMUM 1 -INCH WATER SERVICE O EACH LOT. METER TO BE LOCATED 5 -FEET FROM A SIDE LOT LINE. A3/4 INCH HIGH L '' ETTER "W" SHALL BE CHISELED IN TOP OF EXISTING CURB OR IMPRINTED IN NEW CURB AT ALL WATER SERVICE CROSSINGS. 14. METER BOXES SHALL NOT BE PLACED WITHII I DRIVEWAYS OR SIDEWALKS WITHOUT THE DISTRICTS PRIOR WRITTEN CONSENT. 15. ALL WATER SERVICES FOR IRRIGATION, MUL IPLE RESIDENTIAL COMPLEXES, COMMERCIAL OR INDUSTRIAL DEVELOPMENTS ALL HAVE APPROVED BACKFLOW PREVENTION DEVICE ON CUSTOMER'S SIDE OF I VATER METER. 16. CONTRACTOR SHALL TIE OFF ALL VALVE LO ATIONS AND PROVIDE WRITTEN DIMENSIONS TO INSPECTOR IMMEDIATELY UPON INSTALLATION OF VALVES. 17. LINE VALVES, WHERE REQUIRED AT STREET INTERSECTIONS SHALL BE LOCATED AT THE TEE WHENEVER POSSIBLE. 18. FIRE HYDRANTS, AS APPROVED BY THE APPROPRIATE FIRE DISTRICT AND MEETING THE DISTRICT'S STANDARD SPECIFICATIONS, ARE TC BE INSTALLED AT LOCATIONS SPECIFID BY THE FIRE DISTRICT. 19. ALL DESIGN CHANGES TO THE WATER SYSTE M SHALL BE APPROVED BY THE DISTRICT REPRESENTATIVE IN WRITING PRIOR TO CONSTRUCTION AND ACCEPTANCE OF THE CHANGE. 20. THE WATER SYSTEM SHALL BE PRESSURE TESTED IN ACCORDANCE WITH THE PROCEDURES IN THE OMWD STANDARD SPECIF CATIONS. THE CLASS OF PIPE SHALL BE USED AS THE DESIGNATED WORKING PRESSURE FOR TESTING ALL PIPE, VALVES (CLOSED) AND APPURTENANCES. ,� SITE WORK TO BE DONE ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, ACCEPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE, AND THE SAN DIEGO STANDARD DRAWINGS (LATEST EDITION). ITEM STD. DWG. SYMBOL 8" P.V.C. SEWER (SDR -35) ----------- ------- - --- -- S-4 ----------------------- SEWER LATERAL ------------------- -- --- ----- - - - - -- SS -01,02 ----------- - - - - -- _O SEWER CLEANOUT ---------------- ---- --- --- - - - - - -- SC -01 -- -- -- ---- ------- --- --- O SEWER MANHOLE LINING ------------------- - - - - -- SM -07 --------------- - - - -- TRENCH RESURFACING - - - -- -PER CITY OF ENCINITAS STANDARDS - - - -- CONTRACTOR NOTE: REGARDING UTILITIES NTS EXISTING UTILITIES HAVE BEEN PLOTTED BASED ON AS -BUILT DRAWINGS /DATA PROVIDED BY EACH UTILITY DISTRICT /AGENCY AND HAVE NOT BEEN FIELD VERIFIED. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ADEQUATE MARK - OUT BY CALLING UNDERGROUND ALERT AT 1- 800 -422 -4133 PRIOR TO CONSTRUCTION. ENGINEER TO BE NOTIFIED IMEADIATELY IN THE 22. ALL EXCAVATED MATERIAL SHALL BE CAST AWAY FROM THE IMPROVED PORTION OF EVENT OF A POTENTIAL CONFLICT. THE HIGHWAY. AFTER THE WORK HAS BEEN COMPLETED, ALL EXCESS MATERIAL, INCLUDING TRENCH SPOILS, SHALL BE REMOVED FROM THE RIGHT -OF -WAY. THE RIM ELEVATIONS SHOWN ON THIS PLAN ARE APPROXIMAT. CONTRACTOR IS RESPONSIBLE ROADWAY SHALL BE LEFT IN NEAT AND ORDERLY CONDITION. FOR ADJUSTING FINISH GRADE OF ALL MANHOLES TO THE SATISFACTION OF THE CITY ENGINEER. 23. ALL ROADSIDE DRAINAGE DITCHES SHALL BE RESTORED TO TRUE GRADES AND THE INTAKE AND OUTLET ENDS AT ALL CULVERTS SHALL BE LEFT FREE FROM ALL EXCESS MATERIALS AND DEBRIS. 24. ALL APPROACHES TO PRIVATE DRIVEWAYS AND INTERSECTING ROADS AND STREETS OWNERS AGREEMENT SHALL BE KEPT OPEN TO TRAFFIC AT ALL TIMES, UNLESS OTHERWISE APPROVED BY THE DIRECTOR OF ENGINEERING SERVICES. HEREBY AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS SHOWN ON THESE PLANS 25. CLAY AND EARTH WHICH ADHERE TO THE PAVED SURFACE OF THE ROADWAY SHALL BE REMOVED BY HAND SCRAPING, WASHING AND SWEEPING, OR BY ANY OTHER WITHIN EXISTING CITY RIGHT -OF WAY WITHIN 60 DAYS AFTER ISSUANCE OF THE METHOD WHICH WILL LEAVE A CLEAN NON -SKID SURFACE WITHOUT IMPAIRING, CONSTRUCTION PERMIT AND TO PUSUE SUCH WORK ACTIVLEY ON EVERY NORMAL INJURING OR LOOSENING THE SURFACE. WORKING DAY UNTIL COMPLETED, IRRESPECTIVE AND INDEPENDENT OF ANY OTHER WORK 26. PERMITTEE SHALL COMPLY WITH ANY AND ALL DIRECTIVES ISSUED BY THE ASSOCIATED WITH THIS PROJECT OR UNDER MY CONTROL. DIRECTOR OF ENGINEERING SERVICES OR HIS DULY AUTHORIZED REPRESENTATIVE IN "k �✓ ORDER TO PREVENT DUST OR OTHER MATERIALS FROM BECOMING A NUISANCE OR SIGNATURE: 7� _ ANNOYANCE. _ -_ ________DATE _ 6 r ^, a -, - 27. TEMPORARY PATCHING OF TRENCH IS REQUIRED ON LATERAL CUTS IN SURFACED `" ` STREETS IMMEDIATELY AFTER BACKFILLING. AFTER COMPLETION OF THE REFILLING SIGNATURE:_ _ - - - - - -- DATE` AND COMPACTING OF THE BACKFILL MATERIAL IN THE EXCAVATION, ALL AS SPECIFIED - IN THE STANDARD DRAWING DATED SEPTEMBER 30, 1996, AND THE REMOVAL OF OBSTRUCTION(S), THE PERMITTEE SHALL PROMPTLY REPLACE WITH TEMPORARY OR 18841 SMNCr'ON-AYE SEi17€^ PERMANENT PATCHING MATERIAL, OR REPAIR ANY PORTION OF THE HIGHWAY SURFACE ADDRESS: REMOVED OR DAMAGED BY THE EXCAVATION, OBSTRUCTION, OR CONSTRUCTION ASSESSOR'S PARCEL NUMBER`. APN:265- 354 -05 OPERATIONS, ALL TO THE SATISFACTION OF THE DIRECTOR OF ENGINEERING SERVICES, AND AS SPECIFIED ELSEWHERE HEREIN. THE DIRECTOR OF ENGINEERING IN SUCH CASE` THEPEOPTION, SHALL EAROTHECOSTOFSUC®WORK. REPAIRING TE TEMPORARY HIMSELF; OWNER /PERMITEE SITE LOCATION PATCHING MATERIAL MAY BE LEFT IN PLACE FOR UP TO 30 DAYS, BUT MUST BE CONTINUALLY MAINTAINED. r^ ^' w° 748 RANCHO SANTA FE ROAD ' P ,. ttARPER 28. WHERE THE PAVEMENT, EXCEPT PORTLAND CONCRETE CEMENT PAVEMENT, OR ENCINITAS CA 92024 OTHER TYPE OF SURFACE HAS BEEN REMOVED BY OTHERS, THE PERMITTEE SHALL iPL rmND04G LLC REPLACE IT WITH A STANDARD REPAIR OF FOUR (4) INCHES AC OVER APPROVED - A L.IMITCD Lij%9t41T%j G+1AP," 9 BACKFILL OR REPAIR SECTION SHALL BE ONE (1) INCH AC GREATER THAN EXISTING 440= Ipa$® f►ESS DRIVE STRUCTURAL SECTION, WHICHEVER IS GREATER. REFER TO THE MOST CURRENT °°IrTT" . 92562 - STANDARD DRAWING. REPAIRS TO PCC PAVEMENT SHALL BE MADE PURSUANT TO THE A LA M�S�� GA 91,941 SPECIFICATIONS OF THE ASSIGNED ENGINEERING INSPECTOR. (119 - 2 MFG - Moo 29. IF, AFTER THE REFILLING OF AN EXCAVATION, THE PERMITTEE FAILS OR REFUSES TO -- RESURFACE OR REPAIR THAT PORTION OF THE SURFACE OF THE ROADWAY DAMAGED BY HIM, OR IF THE DIRECTOR OF ENGINEERING SERVICES HAS ELECTED TO DO SUCH - RESURFACING OR REPAIRING, THE DIRECTOR OF ENGINEERING SERVICES SHALL CAUSE -mit 0AR (!sR Folt THE REPAIR TO OCCUR; AND THE PERMITTEE SHALL BE CHARGED WITH THE COST THEREOF COMPUTED BY THE DIRECTOR OF ENGINEERING SERVICES. Sp LLrf4b0 a L4L.G, 30. WHEN SHORING IS REQUIRED, AN ENGINEERED DETAIL DRAWING WILL BE REQUIRED FOR APPROVAL BY THE DIRECTOR OF ENGINEERING SERVICES. ALL OSHA REGULATIONS,' SHALL BE MET, 31. ALL DIRECTIONAL BORES SHALL BE SUBJECT TO APPROVAL OF THE METHOD IN THE FIELD BY THE ASSIGNED ENGINEERING INSPECTOR, ACTING AS THE DULY AUTHORIZED AGENT OF THE DIRECTOR OF ENGINEERING SERVICES. A THOROUGH EXAMINATION OF THE SUBSURFACE CONDITIONS IS A PREREQUISITE. THE APPLICANT SHALL IDENTIFY THE BORE METHOD ON THE PERMIT APPLICATION EITHER AS AUGER, HAMMER, HYDRAULIC, ETC., AND SHOW THE BORE PITS. GROUTING AND INTERMEDIATE BORE PITS MAY E REQUIRED. 32. ALL SUBSURFACE UTILITIES SHALL BE ACCURATELY SHOWN ON THE APPLICANT'S SITE PLAN FOR THOSE EXCAVATIONS IN EXCESS OF 250 LINEAR FEET, TRAVERSING; A. ('r� 7 SIGNALIZED INTERSECTIONS, CROSSING INTERCONNECT WIRES, OR OTHERWISE � WHERE THE DIRECTOR OF ENGINEERING SERVICES HAS A SPECIAL CONCERN. 33. PAVEMENT CUTS IN STREETS REHABILITATED OR NEWLY CONSTRUCTED WITHIN THE f ®. PAST TWO YEARS SHALL BE CATEGORICALLY DENIED. I,�I I FIELD OPERATIONS I PLANNING AND BUILDING I PARKS AND RECREATION I OLIVENHAIN WATER DISTRICT I ENCINITAS FIRE DEPARTMENT I : �°.�- (� SIGN ' DATE - - - -_ / S` I N ATE REwSIONS APPROVED DAZE REFERENCES DAZE BENCHMARK SCALE -As -Bu /GT okra BY PEA IIN eY ENGINEERING DIVISION APPROVALS G� G ow � Nr6 3 roc c�c cAc DESCRIPTION: POINT NO. 1020 PLANS PREPARED UNDER SUPERNSION OF 5 -20 -15 RECOMMENDED JQO APPROVED, 5"- '�' LOCATION: SE CORNER CONIC. F.H.PEDESTAL ORIZONAL Y = 20' g FOR FIRE HYDRANT 100 *S OF CL CAM DEL NORTE C -60957 I� • IL� RECORD FROM: ENCINITAS SURVEY CONTROL '� -Z -I$ R,C,E, NO, BY BY, ELEVATION: 120.56 NETWORK VERTICAL 1 -= 4 �`�/ �"`"'_ 5'a® LS EXP 12_31_1 MASIH MAHER PUBLIC WORKS RECTOR >:" "4f ' OF " K AAT'E GREGORY LL 1 771 DATUM: NAVD88 ENGINEER OF WORK DATE, �' / DATE 6 17 DATE '§I-Glk 0 DATE SIGNATURE EXPIRES 2 YEARS AFTER DATE. CITY OF ENCINITAS PUBLIC WORKS DEP SEWER PLAN AND PROFILE FOR: 748 RANCHO SANTA FE ROAD APN. 265 - 354 -05 JOB NO. 14 -021 DATE : 5 -20 -2015 51�_1 A5 DRAWING NO. 12126 -1 SHEET 1 OF 2 i N h a O ro �I rn II vi vi 2 i z ti 3 2 W� El O II UW Z .N77ON 8" PVCC SE'W ti s 3 II W a U 00 t EX. A.C. SURFACE C• COTRACTOR NOTE: REGARDING UTILITIES EXISTING UTILITIES HAVE BEEN PLOTTED BASED ON AS -BUILT DRAWINGS /DATA PROVIDED BY EACH UTILITY DISTRICT /AGENCY AND HAVE NOT BEEN FIELD VERIFIED. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ADEQUATE MARK - OUT BY CALLING UNDERGROUND ALERT AT 1 -800- 422 -4133 PRIOR TO CONSTRUCTION. ENGINEER TO BE NOTIFIED IMMEDIATELY IN THE EVENT OF A POTENTIAL CONFLICT. RIM ELEVATIONS SHOWN ON THIS PLAN ARE APPROXIMATE. CONTRACTOR IS RESPONSIBLE FOR ADJUSTING FINISH GRADE OF ALL MANHOLES TO THE SATISFACTION OF THE CITY ENGINEER. A" W*- 7EftCt.JE AAE Te 86 P*?WAPC o ?A.feAtTo C9Atrr4ue-yi0A1. Se,wtk A t7,CA -+ /tT_407r . ? t9(. SL Spr►tc .CAto9f AdLow Ti/f /L" sTecC wyTEA!s�/.vF. GRADE EX A.C..._ SURFACE ..." � TvruSED 8" PVC SEWN 303 or',Q 41oi6 Q1 JINVERT@ MAIN DROP TO MAIN I LAT. EL. AT R CAC LAT. SLOPE W `o DEPTH PL TO IE. y __._. D G: -"FATHWAY SPLIT RA1 . 2 ....... RANCHO SANTA FE AD D, G. PATHWAY �. SPLIT RAIL t Z A.C. EX. 12" WTR TERAL DAT 0' 20' 40' 60' SCALE. 1 " = 20' o c FNC S 15 004'07" W 238.50' r 0 0 �rr_._— .._ _- 0 'Z'j 15 °04'07" W NOTES TOPOGRAPHIC FIELD SURVEY PERFORMED ON MAY 25, 2014 BY GAC ENGINEERING AND LAND SURVEYING. CONTOUR INTERVAL EQUALS 1 FOOT. PRIOR TO START OF ANY WORK WITHIN THE PUBLIC RIGHT OF WAY ON RANCHO SANTA FE ROAD, A TRAFFIC CONTROL PLAN MUST BE PREPARED AND APPROVED BY THE CITY OF ENCINITAS ENGINEERING DEPARTMENT. NIGHT WORK MAY BE REQUIRED. ANY PORTION OF EXISTING MEDIAN OR PAVEMENT DAMAGED BY CONSTRUCTIO SHALL BE REPLACED TO THE SATISFACTION OF THE CITY ENGINEER. AN APPROVED TRAFFIC CONTROL PLAN WILL BE REQUIRED PRIOR START OF CONSTRUCTION. FLAGGING OR NIGHT WORK MAY BE REQUIRED. ANY STRIPING DISTURBED DURING CONSTRUCTION SHALL BE RESTORED OR RE PLACED TO THE SATISFACTION OF THE CITY ENGINEER. REVISIONS APPROVED DA 7E REFERENCES DATE BENCHMARK SCALE " w � bi ' 3 7 , DESCRIPTION: POINT N0. 1020 f LOCATION: SE CORNER CONC. F.H.PEDESTAL HORIZONAL 1" = 20' FOR FIRE HYDRANT 100'S OF CL CAM DEL NORTE RECORD FROM: ENCINITAS SURVEY CONTROL ELEVATION: 126.56 NETWORK VERTICAL I- = 4' DATUM:NAVD88 � 40' � w 4 EXIS77NG STREET TREES o° PROTECT IN PLACE bo ° r t+ To PARCEL DE9pVm BY DRA0 BY JINVERT@ MAIN DROP TO MAIN I LAT. EL. AT R CAC LAT. SLOPE LAT. LENGTH GRD. EL.@ RAN DEPTH PL TO IE. UPSTREAM MH RIM EL. BACK WTR VALVE REQUIRED MATERIAL 70 265 - 254 -05 2 +91.56 N74 °55'53 'W 104.63' 1.2' 106.63' 2.2% 45.7' 112.50' 5.87' 110.61' NONE 4" PVC SDR 35 MIN. y __._. D G: -"FATHWAY SPLIT RA1 . 2 ....... RANCHO SANTA FE AD D, G. PATHWAY �. SPLIT RAIL t Z A.C. EX. 12" WTR TERAL DAT 0' 20' 40' 60' SCALE. 1 " = 20' o c FNC S 15 004'07" W 238.50' r 0 0 �rr_._— .._ _- 0 'Z'j 15 °04'07" W NOTES TOPOGRAPHIC FIELD SURVEY PERFORMED ON MAY 25, 2014 BY GAC ENGINEERING AND LAND SURVEYING. CONTOUR INTERVAL EQUALS 1 FOOT. PRIOR TO START OF ANY WORK WITHIN THE PUBLIC RIGHT OF WAY ON RANCHO SANTA FE ROAD, A TRAFFIC CONTROL PLAN MUST BE PREPARED AND APPROVED BY THE CITY OF ENCINITAS ENGINEERING DEPARTMENT. NIGHT WORK MAY BE REQUIRED. ANY PORTION OF EXISTING MEDIAN OR PAVEMENT DAMAGED BY CONSTRUCTIO SHALL BE REPLACED TO THE SATISFACTION OF THE CITY ENGINEER. AN APPROVED TRAFFIC CONTROL PLAN WILL BE REQUIRED PRIOR START OF CONSTRUCTION. FLAGGING OR NIGHT WORK MAY BE REQUIRED. ANY STRIPING DISTURBED DURING CONSTRUCTION SHALL BE RESTORED OR RE PLACED TO THE SATISFACTION OF THE CITY ENGINEER. REVISIONS APPROVED DA 7E REFERENCES DATE BENCHMARK SCALE " w � bi ' 3 7 , DESCRIPTION: POINT N0. 1020 f LOCATION: SE CORNER CONC. F.H.PEDESTAL HORIZONAL 1" = 20' FOR FIRE HYDRANT 100'S OF CL CAM DEL NORTE RECORD FROM: ENCINITAS SURVEY CONTROL ELEVATION: 126.56 NETWORK VERTICAL I- = 4' DATUM:NAVD88 � 40' � w 4 EXIS77NG STREET TREES o° PROTECT IN PLACE bo ° r t+ To z 1 +50 1 6" 1 +00 MEDIAN 0 VOTE. w,.. W EX. 12" A.C.P. WT"TYPii�5 EX 6" A.C. CURB E .D.G. PATHWAY a � N � A UTILITY SEPERATION NOTE: CON7RACTOR TO POTHOLE EXIS77NG 12" A.C.P. WATER MAIN AND r TO MAINTAIN 10' OUTSIDE DIAMETER TO OUTSIDE DIAMETER SEWER MAIN TO WATER MAIN SEPERATION. 112 110 108 106 104 102 100 98 96 94 92 90 88 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, ACCEPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE, AND THE SAN DIEGO STANDARD DRAWINGS (LATEST EDITION). iTEM STD. DWG. SYMBOL 8" P.V.C. SEWER (SDR-35) ----- --- ------ -- -- - -- --- S -4 ---------------- -- --- - -- SEWER LATERAL ---- -------------- --- ------- - - - - - -- SS -01,02 --------------- -- SEWER CLEANOUT - ---- -- ----- --------- --- -- - - - - -- SC -01 --------------- -- - - -- SEWER MANHOLE LINING ------ - - - - -- - ---- - - - - -- SM -07 --------------- - - - -- TRENCH RESURFACING -------- - - - - -- -PER CITY OF ENCINITAS----- - STANDARD DETAIL LEGEND: BOUNDARY /R.O. W.: EXISTING CONTOUR: OVER HEAD POWER LINES. OHP LANE STRIPING SEWER DATA TABLE BEARING RADIUS LENGTH DESCRIPTION ❑ 7 S15 °04'07 "W --- - - - - -- 296.56' 8" PVC SEWER SDR 35 MIN. cOtic EX. 12" WTR RANCID M SANTA FE ROAD _11111 EX. 8" PVC SWR� I EX. 12" WTR pppp o o.0 F 0 +00 CONNECT TO EXISTING MANHOLE PER OUTSIDE DROP CONNEC77ON DETAIL INSTALL SEWER LINING PER NOTE 20.(C) SHEET 1 6d 1 �7 ........._...- 65 ........................ DE9pVm BY DRA0 BY (lfpfm BY ENGINEERING DIVISION APPROVALS CAC C cAC w 10 -31 -14 `QO RECOMMENDED .a a � � R,C,E, NN, 1 C -60957 n BY 0 f!.1'�� EXP. 12—'31 -19 MASIH MAHER GLENN PRUIM PUBLIC ORKSDIRECTOR Ba41�L�st o/x w�sRK GREGORY A. CAUDILL ENGINEER OF WORK DATE 611 fi(1 5 DATE G s3 is z 1 +50 1 6" 1 +00 MEDIAN 0 VOTE. w,.. W EX. 12" A.C.P. WT"TYPii�5 EX 6" A.C. CURB E .D.G. PATHWAY a � N � A UTILITY SEPERATION NOTE: CON7RACTOR TO POTHOLE EXIS77NG 12" A.C.P. WATER MAIN AND r TO MAINTAIN 10' OUTSIDE DIAMETER TO OUTSIDE DIAMETER SEWER MAIN TO WATER MAIN SEPERATION. 112 110 108 106 104 102 100 98 96 94 92 90 88 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, ACCEPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE, AND THE SAN DIEGO STANDARD DRAWINGS (LATEST EDITION). iTEM STD. DWG. SYMBOL 8" P.V.C. SEWER (SDR-35) ----- --- ------ -- -- - -- --- S -4 ---------------- -- --- - -- SEWER LATERAL ---- -------------- --- ------- - - - - - -- SS -01,02 --------------- -- SEWER CLEANOUT - ---- -- ----- --------- --- -- - - - - -- SC -01 --------------- -- - - -- SEWER MANHOLE LINING ------ - - - - -- - ---- - - - - -- SM -07 --------------- - - - -- TRENCH RESURFACING -------- - - - - -- -PER CITY OF ENCINITAS----- - STANDARD DETAIL LEGEND: BOUNDARY /R.O. W.: EXISTING CONTOUR: OVER HEAD POWER LINES. OHP LANE STRIPING SEWER DATA TABLE BEARING RADIUS LENGTH DESCRIPTION ❑ 7 S15 °04'07 "W --- - - - - -- 296.56' 8" PVC SEWER SDR 35 MIN. cOtic EX. 12" WTR RANCID M SANTA FE ROAD _11111 EX. 8" PVC SWR� I EX. 12" WTR pppp o o.0 F 0 +00 CONNECT TO EXISTING MANHOLE PER OUTSIDE DROP CONNEC77ON DETAIL INSTALL SEWER LINING PER NOTE 20.(C) SHEET 1 6d 1 �7 ........._...- 65 ........................ DE9pVm BY DRA0 BY (lfpfm BY ENGINEERING DIVISION APPROVALS CAC C cAC PLANS PREPARED UNDER SUPERW90N OF 10 -31 -14 `QO RECOMMENDED .a APPROVE R,C,E, NN, 1 C -60957 BY, l�' �w� BY f!.1'�� EXP. 12—'31 -19 MASIH MAHER GLENN PRUIM PUBLIC ORKSDIRECTOR Ba41�L�st o/x w�sRK GREGORY A. CAUDILL ENGINEER OF WORK DATE 611 fi(1 5 DATE G s3 is CL CL CO. COVER AND CAN 1' -6' PER SORSO SC -01 FINISH GRADE CO CO WYE FIT71NG 8X8" 8" PVC ' . 8 "•:Ply': 8" PVC SEWER PER PLAN —1 CROSS PVC 8 "X8" — 45DEG BEND 8" PVC 45DEG BEND 8" PVC 2' MIN. EX.M.H. NOTE.• COVER DROP DOWN PIPE AND FITTINGS TO BE THE SAME SIZE AS EN7ERING PIPE CL FINISH GRADE EXISTING SMHR REPLACE EX. CO WITH 8" PVC SPOOL GROUT ANGULAR SPACE 2 -SACK SLURRY BACKFILL DROP S7RUC7URE OUTSIDE DROP CONNECTION NTS CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT DRAWING NO. SEWER PLAN AND PROFILE FOR: 748 RANCHO SANTA FE ROAD APN: 265 - 354 -05 12126 -1 DATE : 41JI115 SHEET 2 OF 2 ........._...- 65 ........................ GAW ���M� EX.M.H. NOTE.• COVER DROP DOWN PIPE AND FITTINGS TO BE THE SAME SIZE AS EN7ERING PIPE CL FINISH GRADE EXISTING SMHR REPLACE EX. CO WITH 8" PVC SPOOL GROUT ANGULAR SPACE 2 -SACK SLURRY BACKFILL DROP S7RUC7URE OUTSIDE DROP CONNECTION NTS CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT DRAWING NO. SEWER PLAN AND PROFILE FOR: 748 RANCHO SANTA FE ROAD APN: 265 - 354 -05 12126 -1 DATE : 41JI115 SHEET 2 OF 2