2017-13689-G (Plans)RIGHT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DIVISION AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS /HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. UTILITY NOTE ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. THE SOILS REPORT TITLED "05- 1147D2(1)" PREPARED BY ECSE, INC. DATED 5/13/2005, AND UPDATE DATED 01/16/2018, PROJECT# 051147D SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID REPORT. 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING. 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER ORA LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 8. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (1/2) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. NOR ON SATUPDAYS, SUNDAYS AND CITY RECOGNIZED HOLIDAYS. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE- CONSTRUCTION MEETING HAS BEEN HELD ONSITE W'TH THE FOLLOWING PEOPLE PRESENT: CITY INSPECTOR, CIVIL ENGINEER, SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE- CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITYAT LEAST 43 HOURS IN ADVANCE BY CALLING (760) 633 -2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL AND /OR FINAL RELEASE OF SECURITY, AN "AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT NO. 13689 -G !!AS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS, 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMOOTH SURFACE AND UNIFORM CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEAT ED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT TOM SANFORD (P(760)685-5877 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 1. FOR STORM WATER POLLUTION CONTROL PURPOSES,I ALL RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIOR TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP/IMP FACILITIES AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITY AND /OR THE TURF /LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BMP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP /BMP. 6. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. 8. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS, NON- COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DUMPSTER IN AND OUT. THE ENCLOSURE SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY - APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM, NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. IMPERVIOUS AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION: IMPERVIOUS AREA AFTER CONSTRUCTION: INCREASE IN IMPERVIOUS AREA: IMPERVIOUS AREA REPLACED: 0 SOFT 7,420 SQFT 7,420 SQFT 0 SOFT EARTHWORK DATA STEEPEST EXISTING NATURAL SLOPE ON -SITE = N/A MAXIMUM VERTICAL DEPTH OF CUT = 3' -6" MAXIMUM VERTICAL DEPTH OF FILL = 2' -6" CUT= 575 C.Y. FILL= 825 C.Y. IMPORT= 250 C.Y.' REMEDIAL= 180 C.Y. (1' -6" REMOVAL AND RECOMPACTION UNDER AND 5' -0" OUTSIDE OF BUILDING AREAS) DISTURBED AREA = 16,800 SQ.FT STORMWATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITIES CONCRETE WASHOUT CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST ASIGN DESIGNATING THE WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL PANELS /PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER, DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST - GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON -SITE, STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAINING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS /DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON - RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL EDCO AT (760) 436 -4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633 -2770. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - LWD 760 - 753 -0155 B. GAS & ELECTRIC - SDGE - (760)- 438 -6200 C. WATER - OLIVENHAIN MUNICIPAL WATER DISTRICT (760) 753 -6466 D. TELEPHONE - SBC BELL - (760)- 489 -3411 E. CABLE TV - COX COMMUNICATIONS - (760)- 806 -9809 X -2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)- 633 -2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760)633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. LA COSTA AVE. OWNER LISA RYAN - CHAPMAN P.O. BOX 2134 LA JOLLA, CA 92038 `t LEUCADIA WASTEWATER DISTRICT PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION SITE ADDRESS ENCINITAS FIRE DEPARTMENT N r_- . p ROJ T E 1459 BELLAAZUL CT. (� X� SITE Z ENCINITAS, CA 92024 e Wilson, Date Dexter Wilson Engineering, Inc. 6/30/2018 Firm Ex . Date o APN:216- 122 -48 SIGN DATE SIG DATE n+ DATE CHANGE NO. DESCRIPTION APPROVED DATE LEGAL DESCRIPTION AS -BUILT APPROVALS 1 DRAWN BY: PARCEL40F PARCEL MAP 20648, IN THE CITY OF ENCINITAS, 0 ENGINEERING DIVISION APPROVALS 1 DRAWING NO. COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TH TO THE MAP THEREOF. FILED IN THE OFFICE OF THE COUNTY 1- Y LEUCADIA BLVD. RECORDER OF SAN DIEGO, APRIL 28, 2009 INT. DATE PLANS PREPARED ! O Y J. VICINITY MAP RECO rr APPROVED: S�E OWAK CHRISTOPHER . MAG OSKU 4 Q Q DATE �� 8'� DATE 3 -` Z'-��(� N.T.S. I (WE) HEREBY CERTIFY THATA REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVERALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBYAGREE TO INDEMNIFY, DEFEND, AND HOLD CITYAND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS, DEMANDS, CAUSES OF ACTIONS, LOSSES, DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE THEREOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNER'S AGENTS, EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK OR CONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. SIGNATURE: DATE: it v SOILS ENGINEER'S CERTIFICATE 1, A REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON 1"1/11/2009 AND FOR AN UPDATE ON 01/16/2018. ONE COMPLETE COPY OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. FURTHERMORE, I HAVE REVIEWED THESE GRADING PLANS AND CERTIFY THAT THE RECOMMENDATIONS INCLUDED IN THE SOILS REPORT FOR THIS PROJECT HAVE BEEN (INCORPORATED IN THE GRADING PLANS AND SPECIFICATIONS. SIGNED:k U" -•'^. ��9,{'b �1a6 Mamadou Saliou Diallo, P.E. RCE NO.: 54071, GE 2704 Y,OPESS1gry EXP. DATE: 12 -31 -19 Lo4�Q- p0 S.6 COMPANY: EAST COUNTY SOIL CONSULTATION & ENGINEERING, INC. iu ADDRESS: 10925 HARTLEY ROAD, SUITE I G62704 SANTEE, CA 92071 x- O PHONE: (619) 258 -7901 (,.'� OT„-_..,,x `4 STATEMENT OF ENGINEER OF WORK THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK PERFORMED BY THE Z" GINEER. SIGNATURE: / e��, DATE: RESSTRUCT 4630 BORDER VILLAGE RD; SUITE N -283, SAN YSIDRO, CA 92173 (760) 415 -3611 RCE 64428; EXP. 6 -30 -19 BMP PROJECT STATUS 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY'S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TREES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION, OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRUNK OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MUST BE PROTECTED I PLACE. EVENS APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MUST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. LEUCADIA WASTEWATER DISTRICT PUBLIC WORKS PLANNING DIVISION PARKS AND RECREATION OLIVENHAIN MUNICIPAL WATER DISTRICT ENCINITAS FIRE DEPARTMENT EWER SYSTEM APPROVAL PUBLIC APPROVED S BY: LWD DISTRICT ENGINEER C33692 S �' V �✓ e Wilson, Date Dexter Wilson Engineering, Inc. 6/30/2018 Firm Ex . Date SI DATE j S N DATE SIGN DATE SIG DATE IGN DATE CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. TS TH CITY OF CARLSBAD CONTROL "CLSB -019" LOCATED THE EN LOCATED AT THE CENTER OF BLUE, 190' S'LY OF INT. OF BELLA VISTA DR. & BELLA LAGUNA CT. 20' E'LY OF C/L INT. DATE PLANS PREPARED ! O Y J. UNDER SUPERVISION OF DATE: 02!20/2018 R.C.E. NO.: 64428 / HRANEK EXP.: 6 -30 -19 RECO rr APPROVED: S�E OWAK CHRISTOPHER . MAG OSKU 4 Q Q DATE �� 8'� DATE 3 -` Z'-��(� GRADING PLAN FOR: 1459 PLANNING CASE NO. BELLA AZUL CT. ENCINITAS CA 92024 , � LISA RYAN - CHAPMAN 16 -120 DRMOD /CDP APN: 216 - 122 -48 13689 -G PUBLIC WORKS ANTHONY J. HRANEK DATE NNING PLANNING REVIEWER CITY ENGINEER DATE INSPECTOR SHEET 1 OF 4 OLIVEN AIN MUNICIPAL ROW WATER DISTRICT NOTES: ENTIRE SITE WITH 'I d6 MONUMENT NOTES: £LLA AZ CT. 353.5 1. POTABLE WATER WORKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE DETAILS AND MATERIALS AS SPECIFIED IN A- f - 23 EXISTING RETAINING r `_ �I 'IT =- °'°.... WALL TO REMAIN THE MOST RECENT EDITION OF THE OLIVENHAIN MUNICIPAL WATER DISTRICT (DISTRICT) STANDARD SPECIFICATIONS AND _ ����, , { 11 ' - - �. ,,, BUILT PER DWG. 947 -G DRAWINGS FOR THE CONSTRUCTION OF WATER MAINS AND FACILITIES, INCLUDING ALL AMENDMENTS ADOPTED PRIOR TO L _ -r r -' r _. ;,. _`_ - ASH£P LINES R£PRESEN THE DISTRICT APPROVAL DATE ON THESE PLANS, CONTRACTOR SHALL HAVE A COPY OF THE STANDARD SPECIFICATIONS C13ND < ACCEPTED 3/4" IRON PIPE • TAG NORTH E , Si 6WI TION 35 - � ON THE JOB SITE AT ALL TIMES. MARKED "LS 5335^ PER PM I6je �r c�P i, PISWI/ T -- - t t ~ - -' PROPOSED RETAINING `' 2. THE SUBMISSION AND REVIEW OF ALL SUBMITTALS (SHOP DRAWINGS, SIX SETS) AS REQUIRED BY THE STANDARD MARKED %S 5335' PER PM IWIS - "' I - ." :' "- _ ,I' 1 r 8' -6' WALL PER SDRSD C -2 nI n '-4" SPECIFICATIONS ARE TO BE ACCOMPLISHED PRIOR TO THE PRE - CONSTRUCTION MEETING WITH THE DISTRICT'S � I. �.. � MAX HT.) - - - - - - - - - INSPECTOR, S89 °27'27 "E 410.29' _ CROSS SECTION A - '� - 3. UNLESS OTHERWISE NOTED, CONNECTIONS TO EXISTING MAINS SHALL BE MADE DRY. THE TIME AND DURATION OF ANY BIO - RETENTION BASIN i - - LOWER PAD d. YARD 334.25 SHUTDOWNS OF EXISTING MAINS SHALL BE SUBJECT TO APPROVAL BY THE DISTRICT. DISTRICT SHALL BE NOTIFIED TWO _ _ _ (SEE DETAIL THIS SH£E WEEKS MINIMUM IN ADVANCE OF ANY SHUTDOWN, - . y.. 4. CONTRACTOR SHALL COORDINATE WITH DISTRICT ALL ARRANGEMENTS FOR HIGH- LINING TEMPORARY SERVICES PRIOR n. r _ 1 - -_ - TO SHUTDOWNS. NO SHUTDOWNS WILL BE SCHEDULED ONA MONDAY OR FRIDAY. - _ 1 _ _ �; _ _ _ - :- - 1 _- �. I. : 5. CONTRACTOR SHALL REVIEW ALL PROPOSED TRENCH WORK WITH CAL/OSHA A COPY OF EXEMPTION LETTER OR r _ i�l _ _ 11 . ". - - _ ��� _ - - r r.� - ,_I, _ TRENCHING PERMIT, IF REQUIRED, SHALL BE SUBMITTED TO THE DISTRICT PRIOR TO CONSTRUCTION. 6. NO WORK MAY BEGIN OR PROCEED WITHOUT DIRECTION OF DISTRICT'S INSPECTOR, CONTRACTOR SHALL NOTIFY THE - DISTRICT INSPECTIONS DEPARTMENT 48 HOURS PRIOR TO THE BEGINNING OF WORK TO ARRANGE FOR INSPECTION OF THE PROJECT. "DIG ROW 7. THE CONTRACTOR MUST CALL ALERT OF SOUTHERN CALIFORNIA" TO HAVE UNDERGROUND SERVICE UTILITIES LOCATED PRIOR TO CONSTRUCTION. THIS CALL WILL BE MADE AT LEAST 48 HOURS IN ADVANCE PRIOR TO ANY WORK m BEING PERFORMED IN PUBLIC RIGHT -OF -WAY. (DIG ALERT PHONE: 800 - 227 -2600) w 8. ALL EXISTING FACILITIES WHICH MAY AFFECT PROJECT CONSTRUCTION, I.E., LINE CROSSINGS, LINE PARALLELING, OR a PROPOSED CONNECTIONS SHALL BE FIELD VERIFIED BEFORE ANY CONSTRUCTION BEGINS. BELLA AZUL 9. THE CONTRACTOR SHALL FURNISH AND INSTALL PER THE STANDARD SPECIFICATIONS THE APPROPRIATE BURIED UTILITY CT, 356.E - WARNING AND IDENTIFICATION TAPE ABOVE ALL PUBLIC WATER LINES INCLUDING WATER LATERALS LOCATED IN PUBLIC POUND • ACCEPTED 37'4^ IRON PIPE a TAG BE 11 RIGHT -OF -WAY. 5 IIG " PER PM retire MARKED "L 5 , RETAINING WALLS 10. WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE PROFILE IS 48- INCHES F?,ER SDRSD C -2 BELOW CENTERLINE OF FINISH GRADE OF STREET. 11. ALL DEFLECTIONS , - _ - �., (5'44 MAX HT.) (HORIZONTAL AND VERTICAL) SHALL BE MADE BY USE OF JOINT COUPLINGS WITH 4° MAXIMUM DEFLECTION PER COUPLING (2° PER JOINT). NO BENDING (CURVING) OF PIPE SHALL BE PERMITTED. �� t i UPPER PAD 345,25 12. MANUAL AIR RELEASES SHALL BE INSTALLED AT ALL HIGH POINTS AND BLOW -OFFS AT ALL LOW POINTS IN THE WATER MAIN ' "�. ' °, if _ - t _ . -� _Y - - I .. - PROFILE. PLACE MANUAL AIR RELEASES AND BLOW -OFFS WITHIN METER BOX AND LOCATE BEHIND CURB UNLESS -- ft, _ _ 11 _ �+ - _ s - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ WALL PER SEPARATE -. _ 17 OTHERWISE APPROVED BY DISTRICT'S REPRESENTATIVE. FIRE HYDRANTS MAY BE USED IN LIEU OF A MANUAL AIR RELEASE \ * -% 1.' - - 8 - .�oqL. P MIT - �'_ - ' OR BLOW -OFF WHEN LOCATED AT OR NEAR HIGH OR LOW POINTS, AS APPROVED BY THE DISTRICT'S REPRESENTATIVE. - I `. . 1y _ -, r .� - � : - � .' � - ALINES 13. INSTALL A MINIMUM 1 -INCH WATER SERVICE TO EACH LOT. METER TO BE LOCATED 5 -FEET FROMA SIDE LOT LINE. A3/4-INCH BEL..a � ( `� ' REPRESENT ti .- "r" - 4 HIGH LETTER "W" SHALL BE CHISELED IN TOP OF EXISTING CURB OR IMPRINTED IN NEW CURB AT ALL WATER SERVICE ,. a, SRI ✓4.eTE ROOT ' -` -�., � ' EXISTING GRADE _ I , L9U)£R �BEYp 3 tit CROSSINGS._ t i _ _ -PAP _ CROSS SECTION B 14.METER.BOXE SHALL S S L NOT BE PLACED WITHIN DRIVEWAYS OR SIDEWALKS WITHOUT THE DISTRICT'S PRIOR WRITTEN `' °� i' 1 _ - - CONSENT. _., In 15. ALL WATER SERVICES FOR IRRIGATION MULTIPLE RESIDENTIAL COMPLEXES, COMMERCIAL OR INDUSTRIAL DEVELOPMENT ° ''- SHALL HAVE APPROVED BACKFLOW PREVENTION DEVICE ON CUSTOMER'S SIDE OF WATER METER. E 16. CONTRACTOR SHALL TIE OFF ALL VALVE LOCATIONS AND PROVIDE WRITTEN DIMENSIONS TO INSPECTOR IMMEDIATELY o e UPON INSTALLATION OF VALVES. 17. LINE VALVES, WHERE REQUIRED AT STREET INTERSECTIONS SHALL BE LOCATED AT THE TEE WHENEVER POSSIBLE. c7' 18. FIRE HYDRANTS, AS APPROVED BY THE APPROPRIATE FIRE DISTRICT AND MEETING THE DISTRICT'S STANDARD SPECIFICATIONS, ARE TO BE INSTALLED AT LOCATIONS SPECIFIED BY THE FIRE DISTRICT. m ��y�o GR. FfL 19. ALL DESIGN CHANGES TO THE WATER SYSTEM SHALL BE APPROVED BY THE DISTRICT REPRESENTATIVE IN WRITING PRIOR TO CONSTRUCTION AND ACCEPTANCE OF THE CHANGE. 20. THE WATER SYSTEM ykp o _ �d�' Y I SHALL BE PRESSURE TESTED IN ACCORDANCE WITH THE PROCEDURES IN THE OMWD STANDARD et1A( �, SPECIFICATIONS. THE CLASS OF PIPE SHALL BE USED AS THE DESIGNATED WORKING PRESSURE FOR TESTING ALL PIPE, BOND D BEAM POOL WALL VALVES(CLOSED)AND APPURTENANCES. 4,`' PERMIT 21. PIPELINES AND APPURTENANCES SHALL BE DISINFECTED IN ACCORDANCE WITH SECTION 15041 OF THE OMWD STANDARD OQ I SPECIFICATIONS PRIOR TO TIE -IN OR CONNECTION TO EXISTING SYSTEM FACILITIES. BACTERIOLOGIC QUALITY TEST RESULTS SHALL CONFORM TO THE CRITERIA SPECIFIED IN THAT SPECIFICATION. ' - - -- - f UPPER PAD 345.25 RETAINING WALLS - 22. CONTRACT RECORD DRAWINGS MUST BE SUBMITTED PRIOR TO FINAL ACCEPTANCE OF WORK. THE PLANS MUST PROVIDE %! ,''J I TI, `I ' :. 'J['�i `a ;,'- ' �' - `I _ DR DHT.) 2 , r POST CONSTRUCTION VERIFICATION OF THE LOCATION AND ELEVATION OF PIPES AND APPURTENANCES. 3 _ 5E4 23, CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF ACCEPTANCE FOR THE _ ,i V _ 3 ' -}_- -i LI - -+;1= - -' REMAIN PROJECT. CONTRACTOR SHALL REPAIR OR REPLACE ANY OR ALL SUCH WORK, TOGETHER WITH ANY OTHER WORK ,,' N I .. _ -7'.,.t ,�� _ - , trt. n M _ Y,� ,. ,, - - - _ SLOPE - TO ;,_ _ , �; yLhi.. .. :- re ° °,I, _ r -I E-� a° - AL WHICH MAY BE DISPLACED IN SO DOING THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND /OR MATERIALS WITHIN THE t' _ - _ _ _ E_ - - DASHED LINES REPRESENT _ _' �. �7,. It- � - \STING NA'TUR - ONE -YEAR PERIOD FROM THE DATE OF ACCEPTANCE WITHOUT EXPENSE WHATSOEVER TO THE DISTRICT, ORDINARY w EXISTING GRADE II '' A LOWER PAD 334,25 - _ WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT EXCEPTED. CROSS SECTION ' TI CR C " 24. ALL IRRIGATION METERS SHALL BE SERVED WITH RECYCLED WATER UNLESS PREVIOUSLY APPROVED IN WRITING BY THE M I �= DISTRICT. g T ,- 25, ALL BURIED FITTINGS AND VALVES SHALL BE WAX TAPE WRAPPED IN ACCORDANCE WITH OMWD STANDARD SPECIFICATIONS. ps Ya Asa Rpw RETENTION AREA SHALL BE LEVEL AND DEPRESSED A MINIMUM OF 6" UC�4D 1,4 UJ,4STEUJ,4TER DISTRICT NOTES: APPROVED COBBLE ENERGY DISSIPATOR GRATE INLET FROM THE SURROUNDING GRADE � PROPOSED 4' -0' HT, ( SPLIT RAIL FENCE ROTED, DENSE, j 6" X 12" PCC CUTOFF WALL / 1. LWD APPROVAL OF THESE PLANS DOES NOT RELIEVE THE APPLICANT, PRIVATE ENGINEER OF WORK, OR CONTRACTOR FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING OR AFTER , PLANTS SOT FOR WELL DRAINED SOIL CONSTRUCTION. 2. ALL DESIGN, DISTRICT LWD 3PECIFOICA a4 PCC NLET FROM SEWER TANDARDS AND OH E ROEQUIRENINOTS OF THE SHTANDARD (EONS FOR PUBLIC WORKS I Cu1roPNF wau HARDWOOD MULCH /GRASS COVER. AREA ORarNS, CONSTRUCTION (GREENBOOK) AND THE REGIONAL STANDARD DRAWINGS, MOST CURRENT EDITIONS. IN THE EVENT OF ° j PROTECT IN PLACE. ,. y r 4,1 ors OR CITY APPROVED EQUIVALENT 4 "-6" LAYER SMOOTH - a CONFLICT THE LWD SEWER STANDARDS GOVERN. REPAIR/REPLACE AS NEEDED, DECORATIVE neDluM 7'3 " -a'7 3. OSHA SAFETY ORDERS AND OSHA CONFINED SPACE ENTRY REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES COBBLE STONE WITHOUT EXCEPTION. EXISTING TYPE 7's -2 ?/.'- _ ` 4. THE CONTRACTOR SHALL HAVE A COPY OF THE DOCUMENTS SPECIFIED IN SEWER NOTES 2 & 3 ON THE JOBSTTE ATALL CURB t GUTTER �� i> ' 4" PERFORATED PVC PIPE < ' a" - 12 24" LAYER ENGINEERED SOIL TIMES. 5. THE CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF FINAL ACCEPTANCE - PROTECT IN PLACE Vjt, ,- ° PLACE PIPE WITH „�"' <� f� `'., -- - = PPE • SEE NOTE BELOW _77_7 -^ ' BY LWD AND SHALL REPAIR OR REPLACE ANY WORK THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND /OR MATERIALS -- Tr _ - PERFORATIONS ,' ;���� ' ':, RISER •°' e: WITHIN THE ONE YEAR PERIOD WITHOUT EXPENSE WHATSOEVER TO LWD. Kr < r # s AT THE INVERT IF 6. PRIOR TO BEGINNING SEWER WORK, CONTRACTOR SHALL SECURE A LWD PERMIT FOR CONSTRUCTION AND SHALL x 2" LAYER - 3" a" �� ` 2 " -3" LAYER OF 3 /a" GRAVEL - PROVIDE A MINIMUM OF 72 HOURS NOTICE TO LWD PRIOR TO CONSTRUCTION. > " x CRUSUED ROCK „ " 2' -3 bOVER OVER PIPE 7. APPROVAL OF THIS PLAN BY LWD DOES NOT CONSTITUTE A REPRESENTATION OF THE ACCURACY OF THE LOCATION OF, OR THE EXISTENCE OR NON - EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE, OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT, 12" MIN. ; 8. ALL REVISIONS TO DRAWINGS SHALL BE APPROVED BY THE LWD DISTRICT ENGINEER IN WRITING PRIOR TO o; .' °S ".� ' :� SE NO ' ° ��^ a t7' ,,a t ,� . ITT/ ' * ; 12' LAYER of 3/4" GRAVEL `�§ s..,,7', �a I2" LAYERR - 3/4" GRAVEL. �', l`, '. d 'ter.,. d::,n:rt BELOW CONSTRUCTION. -u-"t, s �.,. , ..�.i°� •• SEE NOTE BELOW 9. CONNECTIONS TO EXISTING SEWER PIPE OR MANHOLES SHALL ONLY BE DONE IN THE DIRECT PRESENCE OF THE LWD ``° ` �,r ,1 , �' .�.-,; *✓ y INSPECTOR. NEW SEWER SHALL NOT BE CONNECTED OR ALLOWED TO FLOW TO EXISTING SEWER UNTIL AFTER FINAL _ ACCEPTANCE OF ALL UPSTREAM WORK BY THE LWD INSPECTOR OR AS APPROVED BY DISTRICT ENGINEER. CROSS SECTION D 10. ALL SERVICE LATERALS SHALL BE LOCATED AT RIGHT ANGLES TO THE SEWER MAIN UNLESS OTHERWISE SHOWN AS TIE 4" PERFORATED PVC TIE 6" PVC PIPE INTO APPROVED BY LWD ON THE PLANS. EXISTING ROADSIDE swALE- NTS PIPE INTO RISER EXISTING OUTFLOW PIPE 11. A 2 -INCH HIGH "S" SHALL BE INSCRIBED ON THE CURB FACE AT EACH LATERAL BY THE CONTRACTOR. REHABILITATION, 12. A 10 GAGE SHIELDED COPPER WIRE SHALL BE BURIED OVER EACH LATERAL. THE WIRE SHALL EXTEND UP TO A 2" COPPER TAG TIED AND SOLDERED TO THE WIRE. THE TAG OVER THE SEWER MAIN SHALL TERMINATE 6" ABOVE PAVING • 51ORETENTION "ENGINEERED SOIL" LAYER SHALL BE A MINIMUM 24" DEEP "SANDY LOAM" SUBGRADE WITH FINAL LOCATION JUST BELOW PAVING. THE TAG OVER THE CUSTOMER END OF THE LATERAL SHALL SOIL MIX WITH No MORE THAN 5% CLAY CONTENT, THE Mix SHALL CONTAIN 50%-60% EXTEND ABOVE GRADE UNTIL CONNECTED AND SHALL THEREAFTER BE BURIED AT THE POINT OF CONNECTION. SAND, 20 % -30% COMPOST OR HARDWOOD MULCH, AND 20 % -30% TOPSOIL, 13. ALL LATERALS SHALL BE CONSTRUCTED CLEAR OF DRIVEWAYS. N89° 34'11'W 23007' 14. ALL SEWERS AND LATERALS SHALL BE WAYNE BALLED OR JETTED, LOW PRESSURE AIR TESTED, AND TELEVISED AT •• 3/4" CRUSHED ROCK LAYER SHALL BE A MINIMUM of 12" BUT MAY BE DEEPENED THE APPLICANT /CONTRACTORS EXPENSE PRIOR TO CONSIDERATION FOR FINAL ACCEPTANCE BY LWD. AIR TEST SHALL TO INCREASE THE INFILTRATION AND STORAGE ABILITY OF THE BASIN, BE DONE AFTER CONSTRUCTION OF ALL OTHER UTILITIES AND UTILITY LATERALS. 15. ALL SEWERS AND LATERALS SHALL BE IN PLACE AND SHALL HAVE FINAL APPROVAL BY THE LWD INSPECTOR PRIOR TO SDUTREAST CORNER, SWI/4, 5WI14 SECTION 35 THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL AND SHALL BE SIZED BASED PAVING. 16. ALL NEW CONNECTIONS TO EXISTING SEWER SHALL BE MADE TO EXISTING AYES, MADE WITH GASKETED PVC SADDLE wUND e ACCEPTED 3/4" IRON PIPE + TAG MARKED 'L5 5335' PER PM 19619 ON CITY OF ENCINITAS BMP DESIGN MANUAL CALCULATIONS. WYE, OR SHALL BE MADE BY INSTALLING NEW MANUFACTURED WYES. FOR INSTALLING NEW MANUFACTURED WYES, STANDARD BELL AND SPIGOT OR PLAIN END WYES AND PLAIN END PIPE SPOOLS MATCHING THE ADJACENT EXISTING PIPE I �QI V DETAIL MAY BE USED FOR INSERTING WYES INTO AN EXISTING SEWER. ALL CONNECTIONS NOT MADE TO EXISTING WYES MUST BE 3..�����T�� IN ACCORDANCE WITH LWD STANDARD DRAWING S -32. NTS 17. FOR CONNECTION OF NEW LATERALS TO EXISTING PIPE GREATER THAN 8 -INCH DIAMETER CONTRACTOR SHALL CUT IN A NEW WYE PER ABOVE OR MAY USE A SUITABLY SIZED ROMAC STYLE "CB "SEWER SADDLE PER STD. DWG. S- 3 2. 18. IF NECESSARY DURING THE LATERAL CONNECTION WORK, UPSTREAM FLOW IN THE EXISTING SEWER SHALL BE MPORARILY PLUGGED AND BY- PASSED BY PUMPING OR PUMPER TRUCKS FOR DISPOSAL TO A DOWNSTREAM LWD SEWER. IN LOCATIONS WITH SIGNIFICANT UPSTREAM FLOW, FOR CONNECTION OF PLAIN END TO PLAIN END PVC SEWER, I I I FIRE DEPARTMENT NOT�S� MONUMENT NOTE REPAIR COUPLINGS SHALL BE MADE OF PVC MATERIAL MEETING THE SAME MATERIAL REQUIREMENTS AS THE PIPE BEING REPAIRED. PVC SEWER REPAIR COUPLINGS SHALL BE RUBBER GASKETED WITH NO CENTER STOP. PIPE ENDS SHALL BE THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND/OR 1. ALL FIRE APPARATUS ACCESS SHALL HAVE AN LWBSTRUCTED VERTICAL THOROUGHLY CLEANED PRIOR TO INSTALLATION OF THE REPAIR COUPLING(S). THE REPAIR COUPLING SHALL BE SLIPPED BENCHMARKS WHICH WILL DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH CLEARENCE OF NOT LESS THAN 1.3 FEET 6 INCHES. CRC 503.2.1. INSTALL CITY APPROVED APPROVED D VOID FILLER - va"- 3 /a" (NO.9) " ALL THE WAY N ONE PLAIN END PIPE, THEN THE PIPE AND ADJOINING PIPES SHALL BE ALIGNED TOGETHER AND THE POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE 2. FIRE ACCESS ROADS SHALL, BE DESIGNED AND MAINTAINED TO SUPPORT THE PAVER WITH SAP WITH 3/ cftusH£A AGGREGATE L REPAIR COUPLING SLIPPED BACK INTO S POSITION EQUALLY SPACED BETWEEN THE TWO PLAIN END PIPES. PVC SEWER MONUMENTATION BYA LICENSED LAND SURVEYOR OR A REGISTERED CIVIL IMPOSED LOADS OF NOT LESS THAN 75,000 POUNDS AND SHALL BE PROVIDED PACE OR CITY F REPAIR COUPLINGS SHALL BE AS MANUFACTURED BY PW PIPE OR EQUAL APPROVED BY THE LWD DISTRICT ENGINEER. AUTHORIZED TO PRACTICE LAND SURVEYING. A CORNER RECORD OR RECORD WITH AN APPROVED PAVED SURFACE TO PROVIDE ALL WEATHER DRIVING APPROVED EQUIVALENT 19. PVC OR VITRIFIED CLAY PIPE (VCP) SEWER PIPE AND WYES MAY BE USED TO TIE -IN TO EXISTING PCP. FOR OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE LICENSED LAND CAPABILITIES. AMENDMENT 503.2.3 CONNECTION OR REPAIR OF PLAIN END VCP TO VCP A ROMAC INDUSTRIES, INC. STYLE 501 COUPLING OR EQUAL SHALL BE SURVEYOR OR THE REGISTERED CML ENGINEER AS REQUIRED BY THE LAND 3. THE GRADIENT FOR A FIRE APPRATUS ROADWAY, THIS GRADE SHALL NOT °o° ° %' %/ "'" " OF I /9" 6" x i6" ' USED. FOR CONNECTIONS OF VCP TO PVC, A ROMAC INDUSTRIES, INC. STYLE RC 501 REDUCING COUPLING WITH SURVEYOR'S ACT.�� EXCEED 20 %. GRADES EXCEEDING 1.5% (INCLINE OR DECLINE) ON FIRE , _ PCC FLUSH CURB CRUSHED AGGREGATE MATCHING INVERTS, OR APPROVED EQUAL, SHALL BE USED WITH A GASKET RANGE TO MATCH THE OUTSIDE DIAMETER OF APPARATUS ACCESS ROADS SHALL NOT BE PERMITTED WITHOUT MITIGATION. ° THE PIPE ON THAT SIDE OF THE COUPLING BEING JOINED. THE CENTER RINGS SHALL BE DUCTILE IRON PER ASTM A536, MINIMAL MITIGATION SHALL BE ASURFACE OF PORTLAND CONCRETE (PCC). WITH CHOKER COARSE - 2" R OA E GRADE 65 -45 -12 AND SHALL BE PROVIDED WITH 16 MILS FUSION BONDED EPDXY COLOR CODED TO THE TYPE OF A DEEP BROOM FINISH PERPENDICULAR TO THE ENTIR DIRECTION OF TRAVEL, OR ° o o r c ° `snf 4 x. THICK - lNO.SV s'z,x7 CONNECTING PIPE. GASKETS SHALL BE SBR PER ASTM 02000 MBA710, COMPOUNDED FOR WATER AND SEWER SERVICE. EQUIVALENT TO ENCHANCE TRACTION THE ENTIRE LENGTH OF THE GRADE. , ",.:}, j,7''" rya o x x { .,�,xy CRUSHED ROCK ALL NUTS AND BOLTS SHALL BE TYPE 316 STAINLESS STEEL. FOR CONNECTION OF NEW LATERALS TO EXISTING PIPE GREATER THAN 8 -INCH DIAMETER CONTRACTOR SHALL CUT IN NOTE TO CONTRACTOR MIN. 6" THICK 3/4" a o ° t +��,"T¢ ��- CRUSHED ROCK -REFER v�o° o V7' �' x t� ° �� " e. A A WYE PER ABOVE OR MAY USE A SUITABLY SIZED ROMAC STYLE "CB" SEWER SADDLE PER STD. DWG. 5 -32. TO MANUFACTURER SPECS ° ° ° "' d> r 7'f • 21. FINAL APPROVAL OF PLANS BY DISTRICT ENGINEER IS VALID FOR A PERIOD OF TIME NOT TO EXCEED ONE YEAR FROM UTILITIES ARE KNOWN TO EXIST IN THE AREA INFORMATATION SHOWN HEREON IS L _ } _ „ FOR FIRE APPARARTUS (H -20) - :,_ - >t� A[ ,c !S APPROVAL DATE TO START OF CONSTRUCTION. IF THE ONE YEAR TIME LIMIT IS EXPIRED PRIOR TO START OF PER BEST AVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOADING - IF APPLICABLE F ,E31 - OIL SUBGRADE CONSTRUCTION THE DEVELOPER SHALL RESUBMIT THE PLAN CHECK TO THE DISTRICT ENGINEER FOR AN UPDATED LOCATION OF EXISTING UTILITIES IS UNKNOWN. CONTRACTOR TO FIELD VERIFY L G REVIEW AND APPROVAL. ANY CHANGES REQUIRED TO THE PLANS SHALL BE MADE AT THE DEVELOPERS EXPENSE AND LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND Is, - bl - - - Eli APPROVED BY THE LWD DISTRICT ENGINEER PRIOR TO THE START OF CONSTRUCTION. LWD MAY REQUIRE TEMPORARY CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF WORK OF ANY CIVIL ENGINEERING • STRUCTURAL ENGINEERING * LAND PLANNING PROVISION OF DUTY AND BYPASS EQUIPMENT WITH FULL -TIME MANNED MONITORING. NO UNMANNED BYPASS SHALL BE DISCREPANCIES BETWEEN ACTUAL LOCATION AND PLAN LOCATION OF UTILITIES PERMEABLE P 4YER S1 =CTION 4630 SORDER VILLAGE RD: STE. N-283 ALLOWED. UPON DISCOVERY OF DISCREPANCY. SAN DIEGO, CA 52rl3 NTS TONY 0 RESSTRUCT.wm CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS DESIGNED BY: DRAWN BY: CHECKED BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. TS TS TH CITY OF CARLSBAD CONTROL "CLSB- 019", INT. DATE PLANS PREPARED UNDER SUPERVISION OF le RECO E- APPROVED: GRADING PLAN FOR: PUBLIC WORKS STAMPED "ACE CENTER LOCATED AT THE CENTER OF BLUE, 190' S'LY OF INT. OF BELLA VISTA DR. DATUM: NAVD88 DATE: 02/20/2018 / R.C.E. NO.: 64428 Ce AN NY J. HRANEK EXR: 6 -30 -19 C..���� ST NOWAK CHRIST HER L. MAG SKU � t DATE DATE 0�8 1459 SELLA AZUL CT. , ENCINITAS, CA 92024 LISA RYAN CH A - CHAP MAN APN: N CH P MAN 13689 -G ANTHONY J. HRANEK DATE PLANNING -" REVIEWER CITY ENGINEER DATE INSPECTOR SHEET 3 OF 4 PLANNING CASE NO, 16 -120 DRMOD /CDP EROSION CONTROL FLAN EXISTING DRAINAGE BASIN - TO REMAIN OPEN SPACE EASEMENT PER DOC, 2009 -0ISOTI9 REC. 41912009 FUEL MODIFICATION LIMITS NOTE: CONTRACTOR TO MODIFY CONSTRUCTION ENTRANCE AS NECESSARY, CONSTRUCT AND PLACE ALL SEDIMENT BARRIERS TO CHANNEL RUNOFF INTO APPROPRIATE COLLECTION AREAS (TEMPORARY DE- SILTATION BASIN) LEGEND GRAVEL BAGS PER DETAIL "A" THIS SHEET TEMPORARY CONSTRUCTION ENTRANCE - 2 %3" CRUSHED ROCK - MINIMUM 6" DEPTH SLOPE TO TEMPORARY DRAINAGE DITCHES AS NOTED TEMPORARY DE- SILTATION BASIN - - 2" 3" CRUSHED ROCK. MIN, 12" DEPTH TEMPORARY OUTFLOW PIPE LOCATED ' 6" FROM TOP OF BASIN, HYRRO- SEEDING AREA. STRAW MATTING USED IN ADDITION TO OR IN PLACE OF HYDRO - SEEDED AREAS - AS REQUIRED SILT FENCE - PER DETAIL "B" THIS SHEET STRAW WADDLE. NOTE: STRAW WADDLE TO BE BURRIED 2" BELOW TOP OF GRADE, WOOD STAKES USED MINIMUM OF EVERY 8' TO SECURE WADDLE. DETAIL "A" - GRAVEL BAGS GAP BETWEEN BAGS ACTS AS SPILLWAY RUNOFF TWO LAYERS OF BAGS WITH ENDS OVERLAPPED DETAIL I'8" - SILT FENCING 1. SET POSTS AND EXCAVATE A 4" X 4" TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS 2. STAPLE WIRE FENCING TO THE POSTS 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH .d+ 4J BACKFILL AND COMPACT THE SOIL IN AND ADJACENT TO THE TRENCH. )PBS cgte"llCt CIV4L ENGINEERING - STRUCTURAL ENGINEERING * LAND PLANNING 4630 BORDER VILLAGE RD; STE. N-2S3 SAN DEEGO, CA %2M TONY - RESSTRUGT,COM CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK AS -BUILT APPROVALS "t "`'"cu �Y: ""`a °�" : ` "t` "t" "Y: ENGINES ING DIVISION APPROVALS CITY OF ENCINITAS - DEVELOPMENT SERVICES DEPARTMENT DRAWING NO. TS TS TH CITY OF CARLSBAD CONTROL "CLSB -019^ STAMPED TTHE EN LOCATED AT THE CENTER OF BLOB, 190' S'LY OF INT. OF BELLA VISTA DR. & BELLA LAGUNA CT. 20' E'LY OF C/L DATUM: NAVD88 INT. DATE PLANS PREPARED UNDER SUPERVISION OF DATE: 02120/2018 R.C.E. NO.: 64428 L AVRPNY J. HRANEK EXP.: 6 -30 -19 REC APPROVED: .4 'SC STEVE NOWAK CHRIST PHER L. MAG SKU p DATE 3'O DATE D GRADING PLAN FOR: 1459 BELLA AZUL CT., ENCINITAS, CA 92024 LISA RYAN - CHAPMAN PLANNING CASE NO. 16 -120 DRMOD /CDP APN: 216 - 122-48 13689 -G PUBLIC WORKS ANTHONY J. HRANEK DATE PLANNING REVIEWER CITY ENGINEER DATE INSPECTOR SHEET 4 OF 4