2016 12951-SG (Plans)RIMIT OF WAY NOTE OWNER IS TO OBTAIN A CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT OF WAY. FAILURE TO DO SO WILL RESULT IN ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE HIS/HER PROPERTY LINE IS. DRAINAGE NOTE NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. WATER IS TO DRAIN AWAY FROM STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. errs rrV An= ALL UTILITIES SERVING THIS SITE SHALL BE INSTALLED UNDERGROUND. GENEVA, NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS. ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. N/A 3. SEPARATE APPROVALS AND PERMITS FOR ANY CONSTRUCTION WITHIN PUBLIC RIGHT -OF WAY OR EASEMENTS SHALL BE REQUIRED IN CONJUNCTION WITH IMPROVEMENT PLANS. 4. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFFSITE GRADING. 5. CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO CONDITION EXISTING PRIOR TO GRADING, 6. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED SHALL BE FE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 7. THE CONTRACTOR SHALL DESIGN( CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS LAWS AND REGULATIONS. B. GRADING AND EQUIPMENT OPERATING WITHIN HALF (112) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 530 P.M. AND 730 A.M. NOR ON SATURDAYS SUNDAYS AND CITY RECOGNIZED HOLIDAYS. 9. NO GRADING OPERATIONS SHALL COMMENCE UNTIL A PRE - CONSTRUCTION MEETING HAS BEEN HELD ONSITE WITH THE FOLLOWING PEOPLE PRESENT. CITY INSPECTOR, CIVIL ENGINEER SOILS ENGINEER, GRADING CONTRACTOR AND PERMITTEE. THE PRE- CONSTRUCTION MEETING SHALL BE SCHEDULED WITH THE CITY AT LEAST 48 HOURS IN ADVANCE BY CALLING (760) 633 -2770. 10. PRIOR TO HAULING DIRT OR CONSTRUCTION MATERIALS TO ANY PROPOSED CONSTRUCTION SITE WITHIN THIS PROJECT THE DEVELOPER SHALL SUBMIT TO AND RECEIVE APPROVAL FROM THE CITY ENGINEER FOR THE PROPOSED HAUL ROUTE. THE DEVELOPER SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS THE CITY ENGINEER MAY IMPOSE WITH REGARDS TO THE HAULING OPERATION. 11. UPON FINAL COMPLETION OF THE WORK UNDER THE GRADING PERMIT, BUT PRIOR TO FINAL GRADING APPROVAL ADD /OR FINAL RELEASE OF SECURITY, AN 'AS GRADED CERTIFICATION" SHALL BE PROVIDED STATING: "THE GRADING UNDER PERMIT NO .12951 -SG HAS BEEN PERFORMED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED GRADING PLAN OR AS SHOWN ON THE ATTACHED AS- GRADED PLAN ". THIS STATEMENT SHALL BE FOLLOWED BY THE DATE AND SIGNATURE OF THE CIVIL ENGINEER WHO CERTIFIES SUCH GRADING OPERATION. 12. ALL GRADING SHALL BE INSPECTED AND TESTED BY A QUALIFIED SOILS ENGINEER OR UNDER HIS DIRECTION HE SHALL INSPECT AND TEST THE EXCAVATION PLACEMENT AND COMPACTION OF FILLS AND BACKFILLS AND COMPACTION OF TRENCHES. HE SHALL SUBMIT SOILS REPORTS AS REQUIRED AND WILL DETERMINE THE SUITABILITY OF ANY FILL MATERIAL. UPON COMPLETION OF GRADING OPERATIONS HE SHALL STATE THAT OBSERVATIONS AND TESTS WERE MADE BY HIM OR UNDER HIS SUPERVISION AND THAT IN HIS OPINION, ALL EMBANKMENTS AND EXCAVATIONS ARE ACCEPTABLE FOR THEIR INTENDED USE. 13. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURE TO PREVENT EROSION OF FRESHLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 14. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE REMOVED TO SUITABLE FIRM NATURAL GROUND. THE EXPOSED SOILS SHALL BE SCARIFIED TO A DEPTH OF 12 INCHES AND THEN COMPACTED TO A MINIMUM OF 90 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. 15. CUT AND FILL SLOPES SHALL BE CUT AND TRIMMED TO FINISH GRADE TO PRODUCE SMITH SURFACE AND UNIFORMH CROSS SECTION. THE SLOPES OR EXCAVATION AND EMBANKMENTS SHALL BE SHAPED, PLANTED AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STORES, ROOTS AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH AFE LIABLE TO BECOME LOOSENED SHALL BE REMOVED AND DISPOSED OF. THE TOE AND TOP OF ALL SLOPES SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDINANCE. 16. ALL TREES BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED, PILED OR OTHERWISE DISPOSED OF OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS FILL SHALL BE SEGUED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 17. THE REMOVAL OF ANY AND ALL CITY TREES SHALL BE CONSISTENT WITH THE CITY S URBAN FOREST MANAGEMENT PROGRAM. TREES LOCATED WITHIN CITY STREET RIGHT -OF -WAY, ON CITY PROPERTY, OR WITHIN CITY EASEMENTS ARE REFERRED TO AS CITY TRU=ES AND SHALL BE PROTECTED IN PLACE DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED OTHERWISE. NO GRADING, EXCAVATION OR DISTURBANCE OF CITY TREE ROOT SYSTEMS SHALL OCCUR WITHIN THE CITY TREE DRIP LINE AREA (THE AREA FROM THE TRIM OF A TREE TO THE OUTERMOST EDGE OF THE TREE CANOPY PROJECTION ON THE GROUND). IF A CITY TREE IS NOT CLEARLY LABELED TO BE REMOVED, IT MST BE PROTECTED IN PLACE. EVEN IF APPROVED IMPROVEMENTS ARE IN CONFLICT WITH A CITY TREE, IT MIST NOT BE DISTURBED UNLESS THE PLAN IS REVISED TO ADDRESS THE TREE REMOVAL. EAO my OxMRRCtI. 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOSH LICHTMAN AT (858) 245 -9759, 24 FOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. MWN CONTROL 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS THAT ARE UNSAFE OR ARE POTENTIALLY UNSAFE. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. B. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSIGN OF EACH WORK DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. "I ihdi / / 1LI iyla -'i 1. FOR STORM WATER POLLUTION CONTROL PURPOSES ALL R ICFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS SHALL DISCHARGE ONTO GRASS AND LANDSCAPE AREAS PRIM TO COLLECTION AND DISCHARGE ONTO THE STREET AND /OR INTO THE PUBLIC STORM DRAIN SYSTEM. 2. GRASS AND LANDSCAPE AREAS DESIGNATED FOR STORM WATER POLLUTION CONTROL SHALL NOT BE MODIFIED WITHOUT A PERMIT FROM THE CITY. 3. ALL IMPERVIOUS AREAS WITHIN THE SITE SHALL DRAIN TO APPROVED BMP /TAP FACILITIES AND /OR TO TURF OR LANDSCAPED AREAS WITH ADEQUATE GROUNDCOVER PRIOR TO DISCHARGE FROM THE SITE. ALL IMPERVIOUS AREAS MUST SLOPE TOWARD THE APPROVED BMP /IMP FACILITY AND /OR THE TURF /LANDSCAPED AREAS. 4. NO DRAINS SHALL BE INSTALLED IN HARDSCAPE, DRIVEWAYS, OR ANY OTHER IMPERVIOUS AREA UNLESS THE FLOW FROM THE DRAIN DISCHARGES TO AN ADEQUATE IMP /BMP. 5. DRIVEWAYS SHALL HAVE A MINIMUM 2% CROSS SLOPE TOWARD THE IMP /BAP AREA OR HAVE ANOTHER APPROVED DRAINAGE SYSTEM THAT IS DESIGNED TO COLLECT RUNOFF AND DISCHARGE IT TO AN ADEQUATE IMP /BMP. 5. ALL STORMWATER IMP /BMP FACILITIES SHOWN HEREON SHALL NOT BE MODIFIED OR ALTERED WITHOUT A PERMIT FROM THE CITY. 7. THE INSTALLATION OF ADDITIONAL IMPERVIOUS SURFACES NOT SHOWN ON THIS PLAN MAY REQUIRE THAT THIS PLAN BE REVISED OR THAT A SEPARATE ENGINEERING PERMIT BE OBTAINED. B. ALL EXISTING AND PROPOSED TRASH ENCLOSURES SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT PRACTICE REQUIREMENTS. THE TRASH ENCLOSURES SHALL HAVE AN IMPERVIOUS NON - COMBUSTIBLE ROOF THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENIAGS TO HOLD IN ANY LIQUIDS THAT ESCAPE FROM THE DUNPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH ENCLOSURE AREA. THE BERM CAN BE CONSTRUCTED WIDE AND FLAT TO ALLOW ROLLING OF THE DU PSTER IN AND OUT. THE ENCLOSURE E SHALL BE SELF CONTAINED OR MAY HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED OIL/ GREASE SEPARATOR AND IS THEN FILTERED THROUGH A CITY - APPROVED HYDROCARBON FILTER AND DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. SONG WATER N17TES FOR R4R><MM91ENT PLANS• 1. WATER MAINS LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASP). THE CONTRACTOR SHALL AND HEREBY DOES GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE. 2. THE CONTRACTOR SHALL NOTIFY THE DISTRICTS INSPECTION DEPARTMENT 48 HOURS IN ADVANCE OF BEGINNING WOW TO ARRANGE FOR INSPECTION OF PRODECT. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PONE.' (760) 633 -2709. ALL WORK PREFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. 3. THE CONTRACTOR WILL BE REQUIRED TO SCHEDULE A MANDATORY PRE - CONSTRUCTION CONFERENCE WITH THE SAN DIEGUITO WATER DISTRICT INSPECTOR PRIOR TO COMMENCEMENT OF WORK ON WATER IMPROVEMENTS. PHONE: (760) 633 -2709. 4. UNLESS OTHERWISE NOTED, ALL COMECTION6 TO EXISTING MAINS WILL BE MADE BY THE CONTRACTOR UNDER THE SUPERVISION OF SAN DIEGUITO WATER DISTRICT, AFTER PAYMENT UP THE ESTIMATED COST BY THE DEVELOPER. 5. WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE PROFILE IS 48 INCHES BELOW CENTERLINE FINISH GRADE OF STREET. W I t (N 4 :' i t' rl r�K L.' i .� R i ►lN 1 Z+ r ZZrl � �s ►; I sl �� ."l.� P� 7. CONTRACTOR TO FURNISH ONE INCH COPPER WATER SERVICE AND METER BOX FOR EACH FES10ENTIAL LOT. B. CONTRACTORS SHALL ACQUIRE A TRENCHING PERMIT FROM THE CALIFORNIA DIVISION OF SAFETY FOR ALL TRENCH WORK. 9. INSTALL FIRE HYDRANTS 2.5 FEET FROM FACE OF CURB, IF NO SIDEWALK EXISTS OR 7 FEET FROM FACE OF CURB WHERE SIDEWALK EXISTS OR WILL BE CONSTRUCTED. 10. PROVIDE AIR RELEASE ASSEMBLIES AT ALL HIGH POINTS IN WATER MAIN. 11. CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT FROM THE CITY OF ENCINITAS FOR ANY EXCAVATION WITHIN EXISTING CITY RIGHTS -OF -WAY. 12. THE DISTRICT REQUIRES THAT COMPACTION TESTS BE TAKEN WHERE WATER LINES ARE INSTALLED WITHIN EXISTING COUNTY RIGHTS -OF -WAY, CITY OF ENCINITAS RIGHTS -OF-WAY, OR PRIVATE EASEMENTS AND THE RESULTS APPROVED BY THE CITY OF ENCINITAS BEFORE THE WATER LINES ARE ACCEPTED AND A COPY SENT TO THE SAN DIEGUITO WATER DISTRICT OFFICE. 13. PRIOR TO AWARDING WATER LINE CONTRACT, OWNER SHALL ADVISE PROSPECTIVE CONTRACTORS TO OBTAIN AND REVIEW CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASP) SPECIFICATIONS. 14. FILL AREAS MUST BE COMPACTED TO 90% PRIOR TO PIPE INSTALLATION. 15. APPROVAL OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE A REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON- EXISTENCE OF, ANY INDERG30M UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 16. ALL EXISTING FACILITIES WHICH MAY EFFECT FINAL DESIGN I.E. LINE CROSSINGS LINE PARALLELING, OR PROPOSED CONMECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSINGS WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. 17. WATER CONNECTIONS TO COMMERCIAL DEVELOPMENTS SHALL HAVE AN APPROVED BACKFLOW DEVICE INSTALLED TO THE DISTRICTS SATISFACTION AND CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASP) STANDARDS. BACKFLOW DEVICES ARE TO BE INSTALLED DIRECTLY OUTSIDE CITY OR COUNTY RIGHT -OF -WAY OR OUTSIDE WATER DISTRICT EASEMENT. REPAIR, MAINTENANCE AND ANNUAL TESTING OF BACKFLOW DEVICE ARE RESPONSIBILITY OF OWNER. 18. MINI" HORIZONTAL SEPARATION OF 10 FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. 19. UTILITIES TO MAINTAIN MIND" 5 -FOOT SEPARATION WREN PARALLELING WATER SERVICES. 20. CONTRACTOR AND DEVELOPER ARE RESPONSIBLE TO RELOCATE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES VALVE BOXES ETC.) THAT ARE EFFECTED BY THEIR PROJECT. 21. CONTRACTOR TO SUPPLY D000,ENTATION SHOWING THAT ANY ASBESTOS WATER PIPES REMOVED FROM THE GROUND WERE DISPOSED OF IN A MANMER ACCEPTABLE TO THE SAN DIEGO COUNTY WASTE DIVISION. .�: 1 _ 17: , 1 10. 71':�I: •r: ilrl7: 7il�G /I�.ti� 22. USE THE FOLLOWING VARIOUS COMBINATIONS OF PLAIN END PIPE LENGTHS WITH HIGH DEFLECTION COUPLINGS AND INTEGRAL BELL END PIPE FOR CURVED ALIGNMENTS IN BOTH HORIZONTAL AND VERTICAL DIRECTIONS. DO NOT BEND PIPE BETWEEN COUPLINGS. SAW CUT INTEGRAL BELL END OF STANDARD PIPE AND BEVEL ENO FOR USE WITH DEFLECTION COUPLINGS. USE 9.5 -FOOT PLAIN ENO PIPE LENGTHS WITH DEFELCTION COUPLINGS FOR ALL RADII BETWEEN 140 FEET TO 270 FEET. USE 19 -FOOT PIPE LENGTHS WITH DEFELCTION COUPLINGS FOR ALL RADII BETWEEN 270 FEET TO 560 FEET. USE AND INTEGRAL BELL END PIPE LENGTH JOINED TOGETHER WITH A 19 -FOOT PLAIN END PIPE LENGTH TO FORM A CHORD. USE DEFLECTION COUPLINGS ON EACH END OF THE CHORD AND CONTINUE THIS COMBINATION THROUGH THE CURVED ALIGNMENT FOR ALL RADII BETWEEN 560 FEET TO 1,150 FEET. PIPE LENGTHS SHORTER THAN 9 FEET WILL NOT BE USED UNLESS SPECIFICALLY AUTHORIZED THE BY THE DISTRICTS 23. CALIFORNIA STATE LAW ASSEMBLY BILL AB -1953 IS REQUIRING THAT NO -LEAD BRASS BE USED IN THE CONSTRUCTION OR REPAIR OF ALL POTABLE WATER SYSTEM EFFECT JANUARY 1, 2010, IN COMPLIANCE WITH THIS LAW, THE DISTRICT SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. 24. ALL COPPER TUBING USED FOR AIR RELEASES BLOW OFFS AND SERVICES SHALL BE PROVIDED WITH CATHODIC PROTECTION IN ACCORDANCE WITH NC -17 OR WC -18. 25. WATER SERVICES TO BE ABANDONED THAT ARE CONNECTED TO PIPELINES THAT WILL REMAIN IN SERVICE SHALL BE DISCONNECTED AT THE CORPORATION STOP, SHALL HAVE THE CORPORATION STOP REMOVED AND SHALL HAVE A BRASS PLUG INSTALLED,' OR BE ABANDONED AS DIRECTED BY THE SOWD INSPECTOR. �. �• .� � r� •r � a •❑ � r� a is CONCRETE WASHOUT CONTRACTM SHALL ABLISH AND USE AN ADEQUATELY SIZED CONCFETE WASHOUT AREA TO CONTAIN WASHOUT WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING THE WASHOUT LOCATION. CDMISTRR:TTDN RITE ACCF.RR A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH AS 3" CRUSHED ROCK AND /OR CORRUGATED STEEL PANELS /PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION AND BOLD FIBER MATRIX. NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER. DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL PROTECT CHAANELS AGAINST EROSION USING PERMANENT AND TEMPORARY EROSION CONTROL MEASURES. REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UANVECESSARY REMOVAL OF THE NATURAL GROUND COVER. DO NOT REMOVE TREES OR 9-MUUBS UIDFCESSARILY,' THEY HELP DECREASE EROSION. TEMPORARY VEGETATION MST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY FLAMED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED BY PLANTING FAST- GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD AND BIRD THE SOIL. PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON -SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON -SITE. ELIMINATE OR REDUCE POLLUTION OF STORWATER FROM STOCKPILES KEPT ON -SITE. STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROU V THE PERIMETER AT ALL TIMES. TRAINING LR7MCTOAS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO EVERYONE WORKING ON SITE. THE PROPERTY OWNER (S) AND THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ABOUT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND UNUSED CONSTRUCTION MATERIALS. lJ WING OF UNUSED OR WASTE PRODUCTS ON THE GROUND WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED. NO SEEPAGE FROM ANY DUMPSTER SHALL BE DISCHARGED INTO STORMWATER. BERMS /DIKES SHALL BE PLACED AROUND ALL DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSITES SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. DUMPSTEES WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH MATERIAL. MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION CAN BE RECYCLED. NON- RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE. FOR INFORMATION ON DISPOSAL DE HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSIERS CALL EDCO AT (760) 436 -4151. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE TOILETS AWAY FROM STORRCRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER AND STORMORAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL MEASURES AND REQUIREMENTS PLEASE CONTACT THE ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) 633 -2770. STEEPEST EXISTING NATURAL SLOPE ON -SITE = 2 H : 1 V MAXIMUM VERTICAL DEPTH OF CUT = 1.6' MAXIMUM VERTICAL DEPTH OF FILL =-3E' CUT = 50 C.Y. FILL = 100 C.Y. IMPORT -=50 C.Y. REMEDIAL = 100 C.Y. ( I- REMOVAL AND RECOMPACTION UNDER DEVELOPEMENT AREA) DFEAVMt/5 AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION.' 6573 SF D•PERVIOUS AREA AFTER CONSTRCCTIOV 5,565 SF DECREASE IN IMPERVIOUS AREA: 1,107 SF IMPERVIOUS AREA REPLACED.' 0 SF NOTIFICAT OW 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE AFE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUG PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION( FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK.' A. SEWERS - CSO - (760)- 633 -2770 B. GAS & ELECTRIC - SDGE - (760)- 438 -6200 C. WATER - SAN DIEGUITO WATER DISTRICT -1-800 - 227 -2600 D. TELEPHONE - SBC BELL - (760) -489 -3411 E. CABLE TV - COX COM>NMICATIONS- (760)- 806 -9809 X -2233 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEERS OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760) -633 -2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. ROTE (760)633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. OWNER S tERTIF=71F I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. I (WE) HEREBY AGREE TO INDEMNIFY, DEFEND, AND HOLD CITY AND CITY'S OFFICERS, OFFICIALS, EMPLOYEES, AND AGENTS HARMLESS FROM, AND AGAINST ANY AND ALL LIABILITIES, CLAIMS DEMANDS CAUSES OF ACTIONS, LOSSES DAMAGES AND COSTS, INCLUDING ALL COSTS OF DEFENSE TFEFEOF, ARISING OUT OF, OR IN ANY MANNER CONNECTED DIRECTLY OR INDIRECTLY WITH ANY ACTS OR OMISSIONS OF OWNER OR OWNERS AGENTS EMPLOYEES CONTRACTORS, SUBCONTRACTORS OFFICIALS, OFFICERS, OR REPRESENTATIVES FOR ANY AND ALL WORK ORCONSTRUCTION COVERED IN THE PERMIT OR CONNECTED DIRECTLY OR INDIRECTLY TO THE PERMIT OR APPROVED PLANS WITHIN THE PRIVATE PROPERTY OR PUBLIC EASEMENTS. SIGNA ENCINITAS TOWN & COUNTRY SHOPPING CENTER 7855 IVANHOE AVE #333 LA JOLLA, CA 92037 THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEERS TRADE ORPROFESSIONN. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE EN61AEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY PLANCRECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF THE TECHNICAL SUFFICIENCY OR ADEQUACY OF THE PLANS OR DESIGN AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT ACTS ERRORS OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN TFECOUPSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORTH PEEN THEN. SIGNA PASCO LARET SUTTER & ASSOCIATES 535 N. HIGHWAY 101 SOLANA BEACH, CA 92074 (858)259 -8212 RCE EXPIRES. 12 -31 -17 a •Iy No. 71651 Exp. 12/31/17 PASCO LARET SUITER & ASSOCIATES CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 North highway 101, Ste A, Solana Beach, CA 92075 ph 858.259.8212 1 £a 858.259.4812 1 plsaengineering.com VICIN17Y MAP NTS OWNER ENCINITAS TOWN & CONTRY SHOPPING CENTER 7855 IVANHOE AVE #333 LA JOLLA, CA 92037 407 ENCINITAS BLVD ENCINTAS CA. 92024 APAt 258- 112 -32 LEGAL DESMIPTION LOT 4 ACCORDING TO THE MAP THEREOF NO. 8116 FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, 0512811975 1 BMP PROJECT STATUS 1 •J9G:9 FIELD OPERATIONS PLANNING AND BUILDING PARKS AND RECREATION SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT SDWD 16-070 7 SIGN I DATE GS NMM� UQ SIG D E/ SIGN - y 8 D6E SZg �/ DATE CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT ucal�ivcu nr: uhawry d rlrQMAu rrr: ENGINEERING DIVISION APPROVAL CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT L° DRAWING NO. RMA T, lG'I1..A� DESCRIPTION __PT 1031 ENC_31 - PLANS P EPAPED UNDER SUPERVISION OF RECOMMENCE :S APPRO SIMPLIFIED GRADING PLAN FOR LOCATION.' NW_COFRNER OF DRAINAGE BOX t)nl HORIZONTAL: N/A NORTH SIDE OF ENCINITAS BLVD & b (17 DATE.' N1 /� 407 ENCINITAS BLVD R Iz ► -- - _ - 12951 -SG _- - - - - -- -- - - -- 700' EAST., OF WESTLAKE ST. MASIH MA R LENN PRUIM RECORD FROM: ROS X16 _ VERTICAL: _N /A_ BR N I AEL ARDDLINO DATE R.C.E. NO.: -_ 71651 THE CRACK SHACK - -- -- C APN:25S- 112 -32 ELEVATION - 182.995 BR N MICHAEL ARDOLINO 12-31-17 //3 - -- - - -- - DATUM: _ NAVD88 �;» REVIEWER N ECTOR SENIOR ENGINEER EXP.: - -- --- - - - - -- DATE %I G DATE � PLANNING CASE NO: 15 -073 MIN DR CDP SHEET i OF 4 PLSA 2524 y TRAFFI UU \ POSE T T. WALL - STREET LTG v PER SLKiSi B� A & SIGNAL °0' E k \ \ °` .\ \\ \ \ \ LEGEND RIGHT -OF -WAY I cn � �`�., TC= 115.59 -• 1�\ � `�,„ v � \ \ _ TC= 115.43 AY \ v SETBACK LINE . - .. t�LTGHT VAULT IN v v APPROX�LDCATION A v v - - -]y !" \ \ \ OF EX. 12" PVC `uEWER \ \ EXISTING CONTOURS - 55 - VV rC =115 - - 9• � •.�'�'.. � ` V ",�„'., . A \ V A \ \ \ 4� .. \�� \ \ \ \ \ EXISTING SEWER -S S 8(. MALKWAY`\l \ \ \ \ EXISTING WATER -W -- Vd __ ,0 MQ� 4 m G"(� �- "�1 ' n � \ � \ � �N \ \ `�•� \ \ -ice E f APPROX. L TION OF a : a 4 01 TW 120.1. \ C� \ \ \ EXISTING RECYCLED WATER EX. B" AC TER MAIN 1 W ii9. rc- y5 �jBW 119.1 47 8 \ \ PROPOSED MASONRY RET. WALL PER SDRSD C -4 s4 - Tr =115.14 ! S9a ,,pp, �+ _ % 54 " T �� \ \ \ PROPOSED GRAVITY RET. WALL PER SDRSD C -9 \ / i TR.4(FIC NA! VAULT f�c�' ..� v \\ � �, - AF LOCATION OF y�\ \ PROPOSED 42" HIGH SITE FENCE PER ARCH \ ' / TRAFFIC o GFc'AL VAULT / �° w v EX. 18" CCS -DATER MAIN V ° FI6,ER G ffICS VAN 7 - 1„ / r T RET. v v A PROPOSED PCC ROLLED CURS a E= 127.77 \ \ \ \ PER SORSO G -4A & G -4B n Q• �- �! - .-}18; a� AIN THRU CUR \ \\ \ / \ \ EX IMPERVIOUS PCC AREA _ 117 / \ 10" PVC CYCLED TW 91 TRt I \ \ W MAIN \ ~�° PERVIOUS PAVER AREA _n 0 0 1 - 9s DG PATIO AREA , 4Z�Y, .� l , ` 120.1 � v Cox ON t AUL.A f + h c & 1B 35 \ �- F_ ` J ! 11 I _ � � f '° , � F 1 ��119.1 a C' `� \ \ °\� FLOWLINE/ DRAINAGE DIRECTION ! j`v' \ a15. �. �� 3. :: /. - - - -- - -- - -- `%� 6 �`� /l.. �rvq��\ \. \ PROPOSED SD PVC PIPE - - - -" -' FS XXJ( 1} W W_ 1c TG 4 �. 9n" n 7F 118 PROPOSED GRADE CALLOUT TO REMA _(� u� f FS •' t2U. ••,�I•v��O W 1�8 ~ p. I A EXISTING GRAS CALLOUT i - ! .�. e a. �> •. Trt- /.e.� CV F) W3y r \ \ \ LIMIT OF WORK o itn i � e � _ / rt8W 1 5) 0 IN PER PAVER \ 0 3 AROF1�� CT � $ q •''- • • ,1 _ �_ � `° \ PROPOSED BUILDING WALLS c 1 DETAIL .. DISTRICT TO INS ALL I " j - �y ,_ Z \ PROPOSED SEWER SERVICE -S S j 3.2' MAX. . H �' .l' YU " ,. EX. ROOF LINE ABOVE i •.' ® \\ RE YCLE0.WATER ICE I FT. WALL PER (= �N .'+ �L . e -� \ ti` PROPOSED 1" WATER SERVICE W `- TD REMAIN irY?) `. _ \ >> NTER� A \\ KEY MAP �r ,s1{(. .. o.. 4 a . �a �2\, *�^." '` : - WAS L . \ \ FIRE S I TO REMAIN �: � .: 4 ' �.. � ,� _ T.� \,, � 11�i6. - tc=�� PROPOSED 4" SERVICE FS SCALE: 1 " =150' ate\ M� nT/n :CO HE4� PA�g Q . ' - 2.6 4 , -_.. ` >> cs - BW 4 '� . $ .. PROPOSED 1 " RECYCLED WATER SERVICE v '. a- y v RW 12 \q ° >j �, y \ TRENCH RESURFACING �/1��� TRASH ETCL NOTE � 2. FF= Jt1.i` as. rzo:1') v -� <`� 4 ¢ 1 0 THE PROPOSED TRASH ENCLOSURE SHALL BE FITTED TO COMPLY WITH STORM WATER BEST MANAGEMENT I 7 r TC= 114-u " - - < : g,.: . ` .39 PRACTICE REQUIREMENTS. THE TRASH ENCLOSURE SHALL HAVE AN IMPERVIOUS �l- COAffiUSTIBLE ROOF -s\ .. _T? -� _. /- THAT WILL NOT ALLOW RAIN WATER TO ENTER THE ENCLOSURE. THE ENCLOSURE SHALL BE LOCKABLE AND / 8.4 a `•: '�. >f9 �� �� ". 'ITB a < .: 6 ���� > >9 LOCKED WHEN NOT IN USE. A BERM SHALL BE INSTALLED AT ALL OPENINGS TO HOLD IN ANY LIQUIDS X29:56, 4 THAT ESCAPE FROM THE DUMPSTER AND TO PREVENT ANY FLOW OF STORM WATER THROUGH THE TRASH (8 1 5.6) J a Q 0� ",d '. �. ♦ 119.5 ENCLOSURE AREA. THE BERM CAN BE DESIGNED WIDE AND FLAT TO ALLOW ROLLING OF THE OUMPSTER IN AND OUT. THE ENCLOSURE SHALL HAVE A DRAIN THAT DISCHARGES THROUGH AN ADEQUATELY SIZED 'd , y y < - BW BOTTOM OF WALL FINISHED GRADE / TW. s a w -1 B4 \ ' av J'' .71 / EX EXISTING OIL /GREASE SEPARATOR AND THEN IS FILTERED THROUGH ACITY- APPROVED HYDROCARBON FILTER AND FF FINISHED FLOOR DISCHARGED INTO THE PUBLIC SANITARY SEWER SYSTEM NOT TO PLANTERS OR THE STORM DRAIN SYSTEM. ti. ) RA ti \ FG FINISHED GRADE A SEPARATE BUILDING PERMIT MAY BE REQUIRED FOR THIS STRUCTURE. CJiR8TE 3 w 22TIIR2 \ ♦ \ j 0 -EX,� TiI.�' AD_TQ.REMA \ 'RAILROAD TIE v GFF GARAGE FACE FINISHED FLOOR cn l ( REf�ASN IN ` ADJAC& f PRaggm oISTLf6AN E MOTE k: L � REiA3JING W C SE INVERT ELEVATION! ALL THE WORK PROPOSED ON THIS PLAN IS ENTIRELY WITHIN THE APPLICANTS PROPERTY. IF ANY �. " m . e - WALL IC3 TTFnFf / rev`-22G Q3 .\ g v c o a °T7 12136 . "'r \ TW TOP OF WALL @ FINISHED GRADE �' 7 DISTURBANCE TO ADJACENT PROPERTIES IS ANTICIPATED AS A RESULT OF ANY PROPOSED WORD A 4 a d n ° '4 :' b < ' / "' s WRITTEN LETTER OF PERMISSION FROM THE ADJACENT PROPERTY OWNER MUST BE OBTAINED AND K 120.1 a' .� ,� P' iT}✓-121.6 / Sig 4' ` °" ` 4 a . \NL C Tw= 121.1e \ SUBMITTED TO THE CITY PRIOR TO START OF ANY SUCH WORK. ANY DISTURBANCE ON THE ADJACENT I 3 1i8.0I i �..` ,. , PO LS f1S 4 .. a 4 Q �' 1. / gaw =ly9 i4. - _- - Tc= 11x.87 PRIVATE PROPERTY THAT HAS NOT BEEN PREVIOUSLY AUTHORIZED IN WRITING AAfJ SUBMITTED TO THE uND i _ 4 ":4 . tie tee. r;- 4 . �' �, � 4 � . 'FS. 12FT.i`, �• � '�5� °'>�y � r ��g�7= rc= 219.?G 11952 CITY IS GROUNDS FOR A STOP-WORK TO BE ISSUED FOR THE PROJECT UNTIL THE REQUIRED PERMISSION (MOVE uaLVE i .. d . �., a - c -919 6 F \ IS OBTAINED. Lam)(.PfI TO . g .. 4 i 2s. 7 Tw =1 .4B MAIN F NGE AT BE. FEL ) e,� �' FL- 119.18 v 19.35',1'. ( TC= 113,9.. ' �.. e �'7 ..`,p.. a. ..�.'•�...'a..-, m'4 g.'. " 21369 o 4: F m v' 3e SF' @ {TIL 7iJCa q .. Q. q % 5) (BASE71 0 .FRI�fi FOflTPRSN �` ��Q� r,= 199.85 -d.S ` . _ rC- 120.41 d.'1 rr0h �7G= t1Ga0_ FL -198 12Gu4 _.. - - 1 v •i '- . , 17, u.ba FL 1-4. `119.91 W TER MAIN` ! t I \ TALL.. TRASH ENCLOSU E AHEk- ` 4' INSTALL CITY APPROVED . `' a' a o PERVIOUS W/ 3/8" VOID BY ULTIFIATECY'.DTSCENARGE''' � .. / 1.9.71 5' ?REE? L IGH? ttL1 V. LIZ} - - - j 2 410.PUIC SEWER, SYSTEM .. X. WAL TO \ _ OACO AQUABRIC OR CITY TRENCH RESURFACING ! . / 4 VOID FILLER 1 /8" TO 3/B" (NO. 8) e �� .:'. f S' 120 2.. s - a' . REMOVED APPROVED EOUIV I PER CITY OF ENOINIT S INSTALL i" W, ..I I 64 a. �. AGGREGATE IN VOIDS METER AND SE / BEDDING COARSE - 2" THICK OF :K PER STANDARDS c"! m A #A$ .rWS � rn I NI RAILROAD ,I �T Q SEX`.:. SEWER EjXTURES ���% ®__ _ � � t � 1/8„ TO 3/8" (NO. 8) AGGREGATE . ` %� BACKFLOW µETAINTNG WAi- \ TO`'� REMOV0 T f a I �� _ 219.99 1 CHOKER COARSE - 4" THICK OF W I 2986r REMOV `' - rc =113.94 % OR DEEPENED G-1 CURB 112" (NO. 57) CRUSHED ROCK ROLLED _ FL- 719.6/ d� PORTION OF X _ MIN 6" THICK OF 314" rnX. TRADER % �. .�.. 9.6a / ❑ ❑ WALL TO I ° ..1 ., I ° \ (gyp' e q , T MA3N 4A. 6i 3" PAVER _ ..+ ,�Do Igo o� D� CRUSHED ROCK -REFER TO 9 4 a 2 , . / �1" MANUFACTURERS SPECS. U; O I m 1 m \� 119.12 ABAM/C \ ✓ �> s ,r - �) a - C�� oC7[� 1�A7CR = ' " �F AIL PER l -> ( wool j l I I I �'fi�fiI- FOR THICKNESS FOR e��lff �I lil.. FIRE APPARATUS (H -20) 1 I AD= 229.ib TC 11� �. - > 1��.U3 3" F�NrtI MAT v 129.55''- LOADING - IF APPLICABLE 11s� 4 .0 __ o� 118.p1 (I " 1h19671 \ `B ,s PVC SU3DRAIN SOIL SU3GRADE (FS 1190 Y£'�. 21 r19.',\ 129.43 NOTES j 12&.80 a LIMIT OF NORK X119.56 �ti \ ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.). TUN LANES c T I I T T= 7 P \ y MH SI I j T 3 I EX. GfEA TEROEPTOR TO PLACED 119.80 @� Q THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED. r f BY 18GFEASE INTE BY ? EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE. CAST OR APPRQYEB QUAL EX. RAMP TO REMAIN rp NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED. cn \ LID =11 Ps SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL - SU807AIN MAY BE REQUIRED Hf&IALL PERMEABLE ` 119.45 Tc= 213.35 I I I / `\ gs°yq LIG-118. 2 _ ( MAT CURB PAVING PER DETAIL PAVER DETAIL / I + f / / 4T 118.9' i i 1 I 11ET3 WI 1 1923) 119.75 NOT TO SCALE co i \ Tc= 119.62 213.11 113.23 I v % i '18.42 \ \ fr - 1 v / a ._ ( f CID / ROW 5, f ( 118.95 E a \ I \ EX. 4" SEWER TO REMAIN I, PER ARCHITECT CALLE MAGDALENA 1 119 40 lT DG PATIO TBB v 1 S cl 118.64 i l I t >3 \ 7.81 \ EX. C&G ,� y \ R =i .94' (154.0?) \ J M l TO REMAIN I �(. LINE L =1 .92' (154.96\ \ ELECTRIC VAULT ��� 118.35 GRADE v D= T8'39" (54 �OB'14') U \ V A \ I 2' MAX. EXPOSED HT \ \ \ GRAPHIC SCALE 1 " =10' RET. WALL PER SDRSD C -4 SECTION A A NOT TO SCALE ]CK) !! .J PROPOSED TRASH ENCLOSURE PER STRUCTIRAL DETAIL 17/522 -I El EXI5Tl N6 51RUCTURf 2" PCC BEFNf/ 4" INLET 0" HT 5" X 16" DEPTH X 15" PCC FLUSH CURB DASHED LINE EXISTING CON MNI ? t. +, IN'.S PERVIOUS iTALI PAVERS PER DETAIL C 4" O R PCC OVEECMPACTED N GRADE AI (MIN) 4" PCC PIPE DISCHARG WG TO CASE INTERCEPTOR TRASH ENCLOSURE DETAIL 1 1 30" MIL RFE LEER TO BE MTALLEO ALONG EDE I OF EXISTING STRUCTURE IN ORDER TO PREVENT TROEMMIGRATION OF STORWATER INTRODUCED NEAR EXISTM FU MTION AS A RESULT OF THE RMVAL OF THE EXISTING PCC WALK AND TFE INSTALLATION OF PERVIOUS PAVERS EX S7F&7M PERVIOUS PAVERS FOU+DATION PER DETAIL -1 �o� �D °O °D°o� 30" MIN 30 MIL HLPE VIERS i BY STEG'GO -WRAP OR APPROVED EQ. HDPE LINER/ FOUNDATION DETAIL NOT TO SCALE ROW 5.7'l VARIES 42" HIGH FENCE PER ARCHITECT DG PATIO ENCINITAS BLVD Vqq� EX. C&G TO REMAIN OF EX. = w e i;4_ - 1' MAX. SIDEWALK TO HT HET. WALL TO REMAIN SDRSD C -9 TYPE A I535 North iitighway AU1, Ste A, Solana beach, 4;A V;4uy : _ I i \ \ i 0 10 20 30 NOT TO SCALE ph 558.259.8212 1 fa 855.259.4812 1 ptaaengineering.com) \ \ \ CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT TRMA I ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT 214,.17 DESCRIPTION. • _ PT. 1031 ENC -31 PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED.' APPRO D SIMPLIFIED GRADING PLAN FOR: LOCATION.' NW CORNER OF DRAINAGE BOX ON _ - - - -- NORTH SIDE OF ENCINITAS BLVD 6 HORIZONTAL' 1"=10' (o'I� v DATE.' �'�Z''4 __/V�1_ -w- ®� ENCINITAS BLVD - - -- _ - - -- 700' EAST OF WESTLAKE ST__ RECORD FROM: ROS 18415 - VERTICAL: N/A BRIAN MICHAEL ARDOLINO DATE R.C.E. NO.: 71651 MASIH MAHER GLENN PRUIM THE CRACK SHACK - _ - - - - -- -- ELEVATION: - 182.995 _ - _ _ - - BRIAN MICHAEL ARDOLINO - - -- _ 12 -31 -17 -- ANN: 258 °112-32 �3 %d PLANNING CASE NO: 16 -073 MIN DR CDP - - -- - - -- -- - DATUM.' NAVD88 REVIEWER INS ECTOR SENIOR ENGINEER EXP.. - DATE q /�Z �16 DATE / LEGEND _ — HvaFDSEW A07ES RIGHT -OF -WAY - - / J 1. HYDROSEEDING SHAL BE APPLIED TO ALL SLOPES THAT ARE GRADED 6'1 (HORIZONTAL y...•� 'p i SILT FENCE ---- �—�—�- TO VERTICAL) OR STEEPER WHEN THEY AREA: � ' _ A. THREE FEET OR MORE IN HEIGHT IN FILL AREAS GRAVEL BAG INLET GRAVEL BAGS o0000000000 - -- .--- .---- .- -�_.., _ .. .._ B, FIVE FEET OR MORE IN HEIGHT IN CUT AREAS UILESS SLOPE IS NOT SUBJECT TO _._ _.. ti _._ _ -`L_' PROTECTION � - - °" ""�`�° �- _ .. -- ° EROSION DUE TO THE EROSION RESISTANT CHARACTER OF THE MATERIAL AS APPROVED -- CONSTRUCTION FENCE —X i� -�_ �~ _ _ —__ -- ,__ __. S BY T ENGINEER. HE CITY ENGI E }� r i S S S - - - - -- S S S S S _. S \ S -1 2. IRRIGATION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM S \ \ f I LEVEL FOR THE GROWTH OF THE HYDROSEEDED GROWTH. 3. HYDROSEEDING MIX SHALL CONSIST OF ALL THE FOLLOWING. C M m �- - M1 A. SEED MIX SHALL CONSIST OF NO LESS THAN, __._._ _____ I 1. 20 LBS PER ACRE OF ROSE CLOVER CA�� AG�ALE --- - - -- -___ 1 \ 2.20 LBS PER ACRE OF ZORRO FESCUE r �F '�1 \ 3. 3 LBS PER ACRE OF E SCHOOL CIA CALIFORNICA zs-� v V 4, 4 LBS PER ACRE OF ACHILLEA MILLEFOLIA 5. 3 LBS PER ACRE OF ALYSSUM (CARPET OF SNOW) ! W W W yy -i Z.fi . \ I 6. 112 LB PER ACRE OF DIMORPHOLECA W ---�� _ �' W - -W \ C_____, \ 7. ITEMS C, QE AND F OF THIS SUBSECTION MAY BE OMITTED ON LOCATIONS - -W W w \ WHERE THE AREA BEING HYDROSEEDED IS NOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. B. ITEM A OF THIS SUBSECTION MUST BE INOCULATED WITH A NITROGEN FIXING W BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCASTING BEFORE 9. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBSITE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE CERTIFICATION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. GRAVEL BAG INLET -� - \� 10. NON -PHYTO -TOXIC WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY PROTECTION _ - -- a - _ - - - -- AT THE THE CONTRACTOR. - -- - - - - ,-° } _ INSTALL CHAINLINK ��--a' ----- ---- -� - CONSTRUCTION FENCE (( <� \ �� / % ° - - / ✓ < -- �j - — - - - - -- - B. TYPE 1 MULCH APPLIED AT THE RATE OF NO LESS THAN 2,000 LBS PER ACRE. TYPE 6 MULCH ® � c tr •_ / ,�..,.�, � �. �""�� � m "�`� � � •,,�..,�: -` � FIBER MATERIAL. R W) WHEN STRAW UST USED IT MUST BE ANCFIORED TO THE SLOPE BY MECHANICALLY PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOIL. APPLIED p �. _ - - - - - - - - - TING OF AMMONIUM PHOSPHATE SULFATE, 16 -20 -0, WHITH 15% ! - ' r - - - -- - - - - - - -- - _ -- -- - -- - - - .. -. - - - - - SULFUR APPLIED AT THE RATE OF 500 LBS PER ACRE. p} { '_ - C. FERTILIZER CONSISTING 4. AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEEDING BY.' f l / - - - �.:. A. ROUG SILT HENING THE SURFACE TO BE PLANTED BY ANY OR A COMBINATION OF., _ I / 1. TRACK WALKING SLOPES STEEPER THAN 6°.1. FENCE / DETAIL THIS SHEET ` / 2. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEM 1 ABOVE. _ j - B. CONDITIONING THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY.., / t / 1. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED. 2. THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING OR COVERING s SALINE SOILS TO PROVIDE VIABLE CONDITIONS FOR GROWTH. \ \ �> HYDROSEEDED AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR FOR AREAS WHERE HYDROSEEDING IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL SECURITY RELEASED. ADDITIQNAL N07E5 jFIAVEL BAG / 1. EROSION CONTOL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE \ t / 'PER DETAIL T IS SHEET !f i > / MATING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, GRAVEL BAGS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE. MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT \ - __ \ - \ i p O /A, \ f 1 ° / j I MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR 21 STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE. 2. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (DCIA) SHALL BE ALLOWED. DCIA S AOq MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS SUCH AS ROOF, qtly 1� / / ROOF DRAIN, DRIVEWAY, AND STREET. 3. ALL PARCELS ARE SUBJECT TO ARCHITECTURAL DESIGN GUIDELINES FOR FUTURE SINGLE-FAMILY RESIDENTIAL DEVELOPMENT. THESE GUIDELINES ARE AVAILABLE AT CITY / / HALL 05 S. VULCAN AVE, ENCINITAS, CA 92024) AND ARE APPROVED AS PER PC RES. 2006-27. „ r tt a j TWO LAYERS OF GRAVEL BAGS RUNOFF WITH ENDS OVERLAPPED R GAP BETWEEN BAGS _ �,' \ ✓ INSALL�HH►AINLINK` �� / / ACTS AS SPILLWAY \\ CONTRUC ION FENC DETAIL A: GRAVEL BAGS a NOT TO SCALE 11 ! SET POSTS AND EXCAVATE A 2. STAPLE WIRE FENCING TO 4 BY 4 IN (10 BY 10 CM) THE POSTS. \ j TRENCH UPSLOPE FROM AND \ i r BA ! - - f / r g / ALONG THE LINE OF POSTS. \ ) \ T1 I SHEET x / / �4 / I o � 771( /Q. !i / /`�� ��--'/ 4 IN (10 CM) 3. ATTACH THE FILTER FABRIC TO ✓ i \, �� % �� / 4. BACKFILL AND COMPACT THE THE WIRE FENCE AND EXTEND IT EXCAVATED SOIL. INTO THE TRENCH. /J tt -- FILTER FABRIC �Itl =WIRE _ PASCO LARET SUITER - ASSOCIATES GRAPHIC SCALE 1"=10' CIVIL ENGINEERING + LAND PLANNING + LAND SURVEYING 535 North Highway 101, Ste A, Solana Beach, CA 92075 r \\ fi ff �! � // // ph 858.259,8212 fx 858,259.4812 1 plsaen8ineetia8.com 0 10 20 30 r ' i ,, ✓ / DETAIL B: SILT FE�'VCE V / / / %f� f � NOT TO SCALE CHANGE NO. DESCRIPTION AP ROVED DATE BENCHMARK SCALE AS -BUILT ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. RMA ;r __ 'gJIL! _ J {_(P'13 __ DESCRIPTION: - PT 1031 ENC -31 PLA PREPAR UNDER SUPERVISION OF RECOMMENDED: APPR D: SIMPLIFIED GRADING PLAN FOR. LOCATION.' NW CORNER OF DRAINAGE BOX ON _ HORIZONTAL 1 ° -10' 4 ®7 ENCINITAS BLVD - NORTH SIDE OF ENCINITAS BLVD & - C/ L'.`.�1 DATE.., °�•YL•jfj -- --- 4A'-- 1^0� -r, - - - -- 12951 -SG - - - - -- - - -- -- 700' EAST OF WESTLAKE ST. " -- MASIH MAHER GLENN PRUIM RECORD FROM: ROS 18416 VERTICAL: __ N /A" BRIAN MICHAEL A OLINO DATE R.C.E. No.: _ -71651 THE CRACK SHACK - _ - - ELEVATION: OS 182.995 258- '112-32 DATUM: NAVD88 REVIEWER INSPECTOR SENIOR ENGINEER BRIA CHAEL OL EXP : - - 12 -31 -17 DATE_ Ll�b DATE y /3 PLANNING CASE NO: 16 -073 MIN DR CDP SHEET 3 OF 4 PLSA 2524 EASEMENTSIENCUR43RANCES THIS SURVEY IS BASED ON PRELIMINARY REPORT NO. AC'S- 705911 -SD ISSUED BY FIRST AMERICAN TITLE INSURANCE COMPANY DATED DECEMBER 1$ 2014. ENCUMBRANCE ITEMS SUCH AS TAXES, LIENS LEASES, COVENANTS DEEDS OF TRUST, NOTICES AND RIGHTS APPEARING IN SAID POLICY AS ITEMS NO. 1 -12, 27, 2B. 39 -41, 45 -47 AND 50 -52 HAVE BEEN REVIEWED AND ARE NOT CONSIDERED SURVEY RELATED AND HAVE NOT BEEN SHOWN HEREON. ITEMS 32 AND 42 -44 HAVE BEEN INTENTIONALLY DELETED. 13. AN EASEMENT FOR PIPE LINE AND INCIDENTAL PURPOSES RECORDED AUGUST 22, 1925 IN INSTRUMENT NO. 41152, BOOK 1114 PAGE 125 OF DEEDS. IN FAVOR OF SAN DIEGUITO IRRIGATION DISTRICT AFFECTS AS DESM18ED THEREIN 14. AN EASEMENT AND INCIDENTAL PURPOSES RECORDED AUGUST 22, 1925 IN INSTRUMENT AID. 41158, BOOK 1091, PAGE 391 AND INSTRUMENT NO. 41172, BOOK 1122, PAGE 104 ALL OF DEEDS. IN FAVOR OF.' SAN DIEGUITO IRRIGATION DISTRICT AFFECTS: AS DESCRIBED THEREIN THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. 15. AN EASEMENT FOR PUBLIC HIGHWAY AND INCIDENTAL PURPOSES RECORDED MARCH 11, 1930 IN BOOK 1752, PAGE 112 OF DEEDS. IN FAVOR OF.' THE COUNTY OF SAN DIEGO AFFECTS. AS DESCRIBED THEREIN 16. AN EASEMENT AND INCIDENTAL PUkRPOSES IN THE DOCUMENT RECORDED FEBRUARY 21, 1934 AS INSTRUMENT NO. 7229 BOOK 275, PAGE 82 OF OFFICIAL RECORDS. THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. 17. AN EASEMENT AND INCIDENTAL PURPOSES IN THE D000fNT RECORDED FEBRUARY 19, 1934 AS INSTRUMENT NO. 13325, BOWL 472, PAGE 293 OF OFFICIAL RECORDS. THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. 18. AN EASEMENT AND INCIDENTAL PURPOSES IN THE DOC MENT RECORDED DECEMBER 23, 1947 AS INSTRUMENT NO. 133683 BOOK 2591, PAGE 43 OF OFFICIAL RECORDS. THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD 1AFORMATION. 19. AN EASEMENT FOR ACCESS AND UTILITIES AND INCIDENTAL PURPOSES, RECORDED APRIL 29 1953 AS INSTRUMENT NO. 73413 AND JUNE 3 1971 AS INSTRUMENT NO. 116396 ALL OF OFFICIAL RECORDS. IN FAVOR OF: SAN DIEGO GAS & ELECTRIC COMPANY AFFECTS: AS DESCRIBED THEREIN 20. AN EASEMENT FOR EXTEND AND MAINTAIN DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SLOPES BEYOND THE LIMITS OF THE RIGHT OF WAY AND INCIDENTAL PURPOSES RECORDED SEPTEMBER 7, 1967. AS INSTRUMENT NO. 136156 OF OFFICIAL RECORDS. IN FAVOR OF.' THE COUNTY OF SAN DIEGO AFFECTS: AS DESCRIBED THEREIN 21. AN EASEMENT FOR EXTEND AND MAINTAIN DRAINAGE STRUCTURES AND EXCAVATION AND EMBANKMENT SUES BEYOND THE LIMITS OF THE RIGHT OF WAY AND INCIDENTAL ?URPOSES RECORDED OCTOBER 27, 1957. AS INSTRUENT N0. 167682 OF OFFICIAL RECORDS. IN FAVOR OF.' THE COUNTY OF SAN DIEGO AFFECTS: AS DESCRIBED THEREIN 22. AN EASEMENT FOR EXTEND AND MAINTAIN DRAINAGE STRUCTURES AND EXCAVATION AND EMBAMACMENT SLOPES BEYOND THE LIMITS OF THE RIGHT OF WAY AND INCIDENTAL PURPOSES RECORDED NOVEMBER 20, 1968 AS INSTRUMENT, ND. 203577 OF OFFICIAL RECORDS.IN FAVOR OF.' COUNTY OF SAN DIEGO At- FECTS' AS DESCRIBED THEREIN 23. AN EASEMENT FOR WATER AND PUBLIC UTILITIES AND INCIDENTAL PURPOSES, RECORDED MARCH 24, 1975 AS INSTRU4ENT NO. 066513 OF OFFICIAL RECORDS. IN FAVOR OF SAN DIEGUITO IRRIGATION DISTRICT AFFECTS: AS DESCRIBED THEREIN 24. ABUTTERS RIGHTS OF INGRESS AND EGRESS TO OR FROM CALLS MAGDALENA AND ENCINITAS BOULEVARD EXCEPT THE ACCESS POINTS HAVE BEEN DEDICATED OR RELINQUISHED ON THE MAP OF MAP AID. 8115 OF TRACT MAPS RECORDED MAY 28, 1975. 25. AN EASEMENT SHOW OR DEDICATED ON THE MAP FILED OR RECORDED MAY 28, 1975 AS MAP ;0. 8115 OF TRACT MAP FOR.' OPEN SPACE AND INCIDENTAL PURPOSES. 26. AN EAFFMENT SHOWN OR DEDICATED ON THE MAP FILED OR RECORDED MAY 28, 19°:3 FS MAP ND. 8116 OF TRACT MAP FOR FUTURE STREET AND INCIDENTAL PURPOSES. 29. AN EASEMENT FOR ACCESS AND UTILITIES AND INCIDENTAL PURPOSES, RECORDED JANUARY 22 1975 AS INSTRUMENT AD. 76- 027614 OF OFFICIAL RECORDS.IN FAVOR OF.' PACIFIC TELERDE AND TELEGRAPH COMPANY AFFECTS: AS DESCRIBED THEREIN THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. 30. AN EASEMENT FOR PIPE LINES AND INCIDENTAL PURPOSES, RECD APRIL 50, 1976 AS INSTRUMENT NO. 76- 130780 OFFICIAL RECORDS. IN FAVOR OF' SAN DIEGUITO IRRIGATION DISTRICT AFFECTS: AS DESCRIBED THEREIN 31. AN EASEMENT FOR RIGHT OF WAY TOGETHER WITH INGRESS AND EGRESS AND INCIDENTAL PU RPOSE� RECORDED SEPTEMBER 23 1976 AS INSTRUMENT NO. 75- 312780 OF OFFICIAL RECORDS. IN FAVOR OF.' SAN DIEGO GAS & ELECTRIC COMPANY, A CORPORATION AFFECTS: AS DESCRIBED THEREIN THE LOCATION OF THE EASEMENT CANNOT BE DETERMINED FROM RECORD INFORMATION. GRAPHIC SCALE 1 " =40' 0 40 80 120 33. At] EASEMENT FOR FLOOD DRAINAGE CHANNEL AND INCIDENTAL PURPOSES RECORDED MAY 2$ 1980 AS INSTRUMENT N0. 80- 172567 OF OFFICIAL RECOR IN FAVOR OF.' SAN DIEGO COUNTY FLOOD CONTROL DISTRICT - ZONE 1 AFFECTS: AS DESCRIBED THEREIN 34. AN EASEMENT FOR FLOOD DRAINAGE CHARNEL AND INCIDENTAL PURPOSES, RECORDED MAY 2$ 1980 AS INSTRUMENT NO. 80- 172558 OFFICIAL RECORDS. IN FAVOR OF.' SAN DIEGO COUNTY FLOOD CONTROL DISTRICT - ZONE 1 AFFECTS PARCEL B 35. AN EASEMENT FOR PIPE LINES AND INCIDENTAL PUffRPOSES, RECORDED JULY 1, 1980 AS INSTRUENT NO. 80208196 OF OFFICIAL RECORDS. IN FAVOR DF.' SAN DIEGUITO IRRIGATION DISTRICT AFFECTS AS DESCRIBED THEREIN 36. THE TEFL, PROVISIONS AND EASEMENT(S) CONTAINED IN THE DOCUMENT ENTITLED 'PROPERTY BOUNDARY AGREEMENT" RECORDED AUGUST 11, 1980 AS INSTRUMENT ND. 80- 254730 OF OFFICIAL RECORDS. 37. THE TERMS, PROVISIONS AND EASEMENT (S) CONTAINED IN THE DOCUMENT ENTITLED 'B=ASEMENT DEED" RECORDED AUGUST 18, 1980 AS INSTRUMENT NO. 80- 263721 OF OFFICIAL RECORDS. (AFFECTS PARCEL B) 38. AN EASEMENT FOR ACCESS AND UTILITIES AND INCIDENTAL PURPOSES RECORDED MARCH 26, 1997 AS INSTRUMENT NO. 1997 - 0137036 OF OFFICIAL RECORDS.IN FAVOR OF.' SAN DIEGO GAS & ELECTRIC COMPANY. AFFECTS AS DESCRIBED THEREIN. THE LOCATION OF THE EASEMENT CAANdOT BE DETER41AED FROM RECD INFORMATION. 48. AN EASEMENT FOR WATER LINE AND INCIDENTAL PURPOSES, RECORDED MAY 05, 2015 AS INSTRUMENT AID. 2015 - 0221503 OFFICIAL RECORDS. IN FAVOR OF.' SAN DIEGUITO WATER DISTRICT, AN IRRIGATION DISTRICT ORGANIZED AND EXISTING UNDER AND BY VIRTUE OF THE LAWS OF THE STATE OF CALIFORNIA. AFFECTS AS DESCRIBED THEREIN 49. AN EASEMENT FOR TO ERECT, CONSTRUCT, CHANGE THE SIZE OF, IMPROVE, RECONSTRUCT. RELOCATE, REPAIR MAINTAIN AND USE FACILITIES CONSISTING OF UNDERGROUND FACILITIES FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICITY AND COVICATION FACILITIES AND INCIDENTAL PURPOSES RECORDED MAY 22 2015 AS INSTRUMENT NO. 2015 - 0273112 OF OFFICIAL RECOROS.IN FAVOR OF.' SAN DIEGO GAS & ELECTRIC COMPANY, A CORPORATION. AFFECTS. AS DESCRIBED THEREIN tom. - LEGEND PARKING COUNT EASEMENT - SETBACK 24 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT UtblbN A tlT: UHAWN tS7: IYYCIRCU nr: ENGINEERING DIVISION APPR OVAIA CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO" BMA I,. ((y ( DESCRIPTION. PT. 1031 ENC -31 _ PLANS PR IRED UNDER SUPERVISION OF RECOMMENDED' APPR D: SIMPLIFIED GRADING PLAN FOR: LOCATION.' NW CORNER OF DRAINAGE BOX ON - -- - _- _ HORIZONTAL: 1`10' DATE' �, +��' 4 ®7 ENCINITAS BLVD - -- - - -- - - -- - - -- NORTH SIDE OF ENCINITAS BLVD & _ Z-r; -IZ 12951 -SG __ _ _.._.. ____ _ .___ 700 EAST OF WESTLAKE ST. q IZ�� _ _ MASIH MAHER _ GLENN PR - - VERTICAL: N/A BRIAN MICHAEL ;DOULL111NO DATE THE CRACK SHACK RECORD FROM: ROS 18416 R.C.E. NO.: _ 71651__ ELEVATION.' 182.995 _ APN:258- '112 -32 - - -- -- - DATUM: NAVD88 B AN MICHAEL ARDOLINO EXP.: 12 -31 -17 DATE 9 12 (G DATES /L REVIEWER IN ECTOR SENIOR ENGINEER -IMP, _ _._ _. PLANNING CASE NO: 16 -073 MIN DR CDP SHEET 4 OF 4 PLSA 2524 /,