Loading...
8262WORK TO BE DONE A. GENERAL 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (MOST RECENT EDITION). THE DESIGN CONSTRUCTION STANDARDS OF THE CITY OF ENCINITAS AND THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS (MOST RECENT EDITION). ANY CHANGES OR REVISIONS THEREFROM SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ANY REQUEST FOR INSPECTION. 2. WRITTEN PERMISSION SHALL BE OBTAINED FOR ANY OFF -SITE GRADING. 3. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING GRADING OPERATIONS. ANYTHING DAMAGED OR DESTROYED SHALL BE REPLACED OR REPAIRED TO THE SATISFACTION OF THE ENGINEER AT NO COST TO THE CITY. 4. THE CONTRACTOR SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS DISTURBED OR DESTROYED DURING CONSTRUCTION SHALL BE REESTABLISHED AND REPLACED BY A STATE OF CALIFORNIA REGISTERED CIVIL ENGINEER OR STATE OF CALIFORNIA LICENSED LAND SURVEYOR TO THE SATISFACTION OF THE ENGINEER AND AT NO COST TO THE CITY. 5. THE CONTRACTOR SHALL DESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE, AND FEDERAL SAFETY HEALTH STANDARDS, LAWS, AND REGULATIONS. 6. GRADING AND EQUIPMENT OPERATING WITHIN ONE -HALF (j) MILE OF A STRUCTURE FOR HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 4:00 PM AND 7:30 AM NOR ON SATURDAYS, SUNDAYS, AND CITY RECOGNIZED HOLIDAYS. 7. THE STRUCTURAL SEC11ON OF ALL RESURFACING SHALL BE IN ACCORDANCE WITH THE CITY OF ENCINITAS ENGINEERING STANDARDS, AS SHOWN ON THESE PLANS, AND AS APPROVED BY THE CITY ENGINEER. 8. APPROVAL OF THESE IMPROVEMENT PLANS DOES NOT CONSTITUTE APPROVAL OF ANY WORK OUTSIDE THE PROJECT BOUNDARY. 9. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL BE CONSTRUCTED, CONNECTED, AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER, AND PAVING. 10. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE OBTAINED FROM A BASE UTILITY MAP AND SEARCH OF THE AVAILABLE RECORDS TO THE BEST OF OUR KNOWLEDGE. HOWEVER, THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT EXISTING FACILITIES SHOWN HEREON AND OTHERS WHICH ARE NOT OF RECORD OR NOT SHOWN ON THESE PLANS. 11. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE DONE SHALL CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATION'S' (POTHOLING) AND LOCATE ALL EXISTING UNDERGROUND FACILITIES IN THE PROJECT AREA SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES. 12. A. CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS & ELECTRIC COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE SAID WORK WITH COMPANY REPRESENTATIVES. 1- 800 - 422 -4133 (DIG ALERT) B. THE CONTRACTOR SHALL NOTIFY THE AT &T COMMUNICATIONS COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE SAID WORK WITH COMPANY REPRESENTATIVES. 1 -619- 546 -3606 C. THE CONTRACTOR SHALL NOTIFY SAN DIEGUITO WATER DISTRICT PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE SAID WORK WITH COMPANY REPRESENTATIVES. 1- 760 -633 -2709 D. THE CONTRACTOR SHALL NOTIFY COX CABLE TELEVISION PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE SAID WORK WITH COMPANY REPRESENTATIVES. 1- 800 - 422 -4133 (DIG ALERT) E. THE CONTRACTOR SHALL NOTIFY THE SAN ELIJO JPA COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES (RECLAIMED WATER) AND SHALL COORDINATE SAID WORK WITH COMPANY REPRESENTATIVES. 1- 760 - 753 -6203 (EXT. 32) 13. THE CONTRACTOR SHALL PROTECT EXISTING LANDSCAPING AND IMPROVEMENTS REMAINING IN PLACE AND THAT ARE NOT CALLED OUT TO BE REMOVED ON THESE PLANS. NO LANDSCAPING OR IMPROVEMENTS SHALL BE DAMAGED OR REMOVED PRIOR TO APPROVAL OF THE CITY. 14. EXCEPT WHEN WORK IS BEING DONE ON DRIVEWAYS, THE CONTRACTOR SHALL MAINTAIN ACCESS TO PRIVATE DRIVEWAYS AT ALL TIMES. 15. ALL PRIVATE IMPROVEMENTS IN THE PUBLIC RIGHT OF WAY DESIGNATED TO BE REMOVED SHALL BE SALVAGED AND RETURNED TO THE PROPERTY OWNER. ALL PRIVATE IMPROVEMENTS OUTSIDE THE PUBIC RIGHT OF WAY, THAT ARE NOT DESIGNATED TO BE REMOVED, THAT ARE DAMAGED DURING CONSTRUCTION OF THE PROJECT SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE CITY. 16. THE CONTRACTOR SHALL NOTIFY IN WRITING AND OBTAIN APPROVAL OF THE CITY ENGINEER OF WORK PRIOR T@ MAKING CHANGES IN THE FIELD. 17. NOTES AND DETAILS AN THE PLANS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES IN CASE OF CONFLICT. 18. THE CONTRACTOR SHALL MAINTAIN AN UP TO DATE SET OF AS -BUILT DRAWINGS ON WHICH ALL CHANGES OR VARIATIONS IN THE WORK, INCLUDING UTILITIES ARE RECORDED. A COPY OF SAID AS -BUILT DRAWINGS SHALL BE PROVIDED TO THE CITY OF ENCINITAS WHEN REQUESTED. 19. MATERIAL OF DEBRIS SHALL NOT BE STORED OR REMAIN IN THE PUBLIC RIGHT OF WAY WITHOUT APPROVAL BY THE CITY ENGINEER 20. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) NOTE: THE CONTRACTOR IS REQUIRED TO OBTAIN A PERMIT FROM OSHA PRIOR TO COMMENCING CONSTRUCTION OF TRENCHES OF EXCAVATIONS WHICH ARE 5 FOOT OR DEEPER AND INTO WHICH A PERSON IS REQUIRED TO DESCEND. B. NOTIFICATIONS 1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES AND STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE FOLLOWING OWNERS OF SAID UTILITIES OR STRUCTURES PRIOR TO ANY EXCAVATION, FOR VERIFICATION AND LOCATION OF UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK: A. SEWERS - LWD - (760)- 753 -0155 B. GAS & ELECTRIC - SDGE - (760)- 438 -6200 C. WATER - SAN DIEGUITO WATER DISTRICT -1- 800 - 227 -2600 D. TELEPHONE - SBC BELL - (760) -489 -3411 E. CABLE TV - COX COMMUNICATIONS- (760)- 806 -9809 X -2233 F. RECLAIMED WATER - SAN ELIJO JPA 2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE 48 HOURS PRIOR TO BEGINNING ANY WORK ON THIS PROJECT. PHONE: (760)- 633 -2770. 3. THE CONTRACTOR SHALL GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760) 633 -2770. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. PLANS FOR THE CONSTRUCTION OF PAUL ECKE CENTRAL IMPROVEMENTS N THE DTY OF ENCHTAS S11 EARTHWORK QUANTITIES TOTAL CUT 347 CY TOTAL FILL 7 CY NET TOTAL 340 CY EXPORT VICINITY MAP NOT TO SCALE PROJECT LOCATION ALONG VULCAN AVENUE IN FRONT OF PAUL ECKE ELEMENTARY SCHOOL ENCINITAS, CALIFORNIA 92024 SHEET INDEX SHEET DESCRIPTION 1 TITLE SHEET 2 INDEX MAP, TYPICAL SECTIONS & DETAILS 3 SIDEWALK IMPROVEMENT PLAN 4 RETAINING WALL & STORMDRAIN PLAN 5 SIGNING & STRIPING PLAN r e C 71007 *\ `EXP..EZWJ_7_ li 12161104, . • 001 m b• THE IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FOLLOWING DOCUMENTS: 1. SAN DIEGO AREA REGIONAL STANDARD DRAWINGS 2. STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ( "GREEN BOOK ") 3. STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION (CALTRANS) STANDARDS PLANS 4. STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION (CALTRANS) STANDARD SPECIFICATIONS 5. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES ( MUTCD) 6. STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL TO MUTCD C. GRADING 1. THE CONTRACTOR SHALL PROPERLY GRADE ALL EXCAVATED SURFACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE /SHE SHALL CONTROL SURFACE WATER AND AVOID DAMAGE TO ADJOINING PROPERTIES OR TO FINISHED WORK ON THE SITE AND SHALL TAKE REMEDIAL MEASURES TO PREVENT EROSION OF FRIENDLY GRADED AREAS UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 2. ALL AREAS TO BE FILLED SHALL BE PREPARED TO BE FILLED AND FILL SHALL BE PLACED IN ACCORDANCE WITH STANDARD SPECIFICATIONS. ALL VEGETABLE MATTER AND OBJECTIONABLE MATERIAL SHALL BE REMOVED BY THE CONTRACTOR FROM THE SURFACE UPON WHICH THE FILL IS TO BE PLACED. LOOSE FILL AND ALLUVIAL SOILS SHALL BE SCARIFIED TO A DEPTH OF 6" AND THEN COMPACTED TO A MINIMUM OF 92 PERCENT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PLACE, SPREAD, WATER, AND COMPACT THE FILL IN STRICT ACCORDANCE WITH SPECIFICATIONS. SMOOTH SURFACES AND UNIFORM CROSS SECTIONS. THE SLOPES OF EXCAVATIONS AND EMBANKMENTS SHALL BE SHAPED, PLANTED, AND TRIMMED AS DIRECTED BY THE ENGINEER OF WORK AND LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS, AND OTHER WASTE MATTER EXPOSED OR EXCAVATION OR EMBANKMENT SLOPES WHICH ARE LIABLE TO BECOME LOOSENED SHALL BE ROUNDED IN ACCORDANCE WITH THE GRADING ORDNANCE. 4. ALL TREES, BRUSH, GRASS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE COLLECTED AND HAULED OFF THE SITE BY THE CONTRACTOR SO AS TO LEAVE THE AREAS THAT HAVE BEEN CLEARED WITH A NEAT AND FINISHED APPEARANCE FREE FROM UNSIGHTLY DEBRIS. APPROVAL OF LOCATION OF DEBRIS ALL SHALL BE SECURED FROM THE SOILS ENGINEER AND CITY ENGINEER PRIOR TO THE DISPOSAL OF ANY SUCH MATERIAL. 5. THE CONTRACTOR SHALL MAINTAIN ADEQUATE DUST CONTROL MEASURES THROUGHOUT THE DURATION OF THE PROJECT CONSTRUCTION. PROJECT SITE MAINTENANCE SHALL CONFORM TO SECTION 7 -8 OF THE STANDARD SPECIFICATIONS. SAN DIEGUITO WATER DISTRICT NOTES: 1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC). THE CONTRACTOR SHALL AND HEREBY DOES GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE. 2.THE CONTRACTOR SHALL NOTIFY THE DISTRICT'S INSPECTION DEPARTMENT 48 HOURS IN ADVANCE OF BEGINNING WORK TO ARRANGE FOR INSPECTION OF PROJECT. THE CONTRACTOR SHALL, GIVE 24 HOURS NOTICE ON CALLS FOR INSPECTION. PHONE: (760) 633 -2709. ALL WORK PREFORMED WITHOUT BENEFIT OF INSPECTION WILL BE SUBJECT TO REJECTION AND REMOVAL. 3.THE CONTRACTOR WILL BE REQUIRED TO SCHEDULE A MANDATORY PRE - CONSTRUCTION CONFERENCE WITH THE SAN DIEGUITO WATER DISTRICT INSPECTOR PRIOR TO COMMENCEMENT OF WORK ON WATER IMPROVEMENTS. PHONE: (760) 633 -2709. 4.UNLESS OTHERWISE NOTED, ALL CONNECTIONS TO EXISTING MAINS WILL BE MADE BY THE CONTRACTOR, UNDER THE SUPERVISION OF SAN DIEGUITO WATER DISTRICT, AFTER PAYMENT OF THE ESTIMATED COST BY THE DEVELOPER. 5.WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE PROFILE IS 48 INCHES BELOW CENTERLINE FINISH GRADE OF STREET. 6.ALL SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS. 7.CONTRACTOR TO FURNISH ONE INCH COPPER WATER SERVICE AND METER BOX FOR EACH RESIDENTIAL LOT. &CONTRACTORS SHALL ACQUIRE A TRENCHING PERMIT FROM THE CALIFORNIA DIVISION OF SAFETY FOR ALL TRENCH WORK. 9.INSTALL FIRE HYDRANTS 2.5 FEET FROM FACE OF CURB, IF NO SIDEWALK EXISTS, OR 7 FEET FROM FACE OF CURB WHERE SIDEWALK EXISTS OR WILL BE CONSTRUCTED. 10. PROVIDE AIR RELEASE ASSEMBLIES AT ALL HIGH POINTS IN WATER MAIN. 11. CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT FROM THE CITY OF ENCINITAS FOR ANY EXCAVATION WITHIN EXISTING CITY RIGHTS -OF -WAY. 12. THE DISTRICT REQUIRES THAT COMPACTION TESTS BE TAKEN WHERE WATER LINES ARE INSTALLED WITHIN EXISTING COUNTY RIGHTS -OF -WAY, CITY OF ENCINITAS RIGHTS -OF -WAY, OR PRIVATE EASEMENTS, AND THE RESULTS APPROVED BY THE CITY OF ENCINITAS, BEFORE THE WATER LINES ARE ACCEPTED AND A COPY SENT TO THE SAN DIEGUITO WATER DISTRICT OFFICE. 13. PRIOR TO AWARDING WATER LINE CONTRACT, OWNER SHALL ADVISE PROSPECTIVE CONTRACTORS TO OBTAIN AND REVIEW CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) SPECIFICATIONS. 14. FILL AREAS MUST BE COMPACTED TO 90 %, PRIOR TO PIPE INSTALLATION. IMPERVIOUS AREA IMPERVIOUS AREA PRIOR TO CONSTRUCTION: 100 SOFT IMPERVIOUS AREA AFTER CONSTRUCTION: 3,100 SQFT INCREASE IN IMPERVIOUS AREA: 3,000 SOFT IMPERVIOUS AREA REPLACED: 132 SOFT I BMP PROJECT STATUS 1 STANDARD STORMWATER TREATMENT FACILITIES TO BE MAINTAINED BY CITY OF ENCINITAS PUBLIC WORKS DEPT. IN ACCORDANCE WITH "MAINTENANCE AGREEMENT. I FIELD OPERATIONS I PLANNING AND BUILDING I SAN DIEGUITO WATER DISTRICT I ENCINITAS FIRE DEPARTMENT 1 gftlil DATE * '4e 7-8-146 APPROVED BY DATE CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS- BUILT uts tsr: DRAWN BY: crlecKtu BY: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT/ DRAWING NO. mivv MJW M W ED SEE SHEET 2 HORIZONTAL: NONE VERTICAL: NONE Q,_ ® ® �� a _w /ly /` PLANS PREPARED UNDER SUPERVISION OF DATE:��'L R.C.E. NO.: 71087 �' MAT EWJ. WIDELSKI EXP.: 6/30!2017 RECOMMENDED: APPROVE 7� DATE: 7.8.14 DATE: R.C. E. 489'!/ R.C.E. S /Y7y IMPROVEMENT PLAN FOR: PAUL ECKE CENTRAL IMPROVEMENTS 256- 301 -01 WORK ORDER NO: CS16D SI -103 ENGINE S NAME DATE SHEET 1 OF 5 D. EROSION CONTROL 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT GREG SHIELDS AT (760) 633 -2778, 24 HOURS A DAY. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE ON OCTOBER 1 AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. 3. CONTRACTOR SHALL PROVIDE A 24 -HOUR TELEPHONE NUMBER AND NAME OF PERSON RESPONSIBLE FOR EMERGENCY WORK. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO AN INCOMPLETE GRADING OPERATION OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40 %). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE EROSION CONTROL DEVICES AS NECESSARY. 8. ALL EROSION CONTROL MEASURES REQUIRED TO RETAIN SEDIMENT ONSITE AND TO SAFELY DISCHARGE ANY ACCELERATED RUNOFF GENERATED BY THE PROJECT SHALL BE INSTALLED WHEN THE 5 -DAY RAIN PROBABILITY FORECAST EXCEEDS 40 PERCENT. 9. TEMPORARY EROSION CONTROL DEVISES WHICH INTERFERE WITH WORK SHALL BE RELOCATED OR MODIFIED AS THE WORK PROGRESSES AS RECOMMENDED BY THE ENGINEER OF WORK AND AS APPROVED BY THE CITY ENGINEER. 10. EROSION CONTROL SYSTEMS SHALL BE SERVICED AND MAINTAINED TO PROVIDE CONTINUOUS CAPACITY AND ADEQUACY TO FUNCTION AS DESIGNATED. AFTER PRECIPITATION EXCEEDING ONE QUARTER (j) INCH IN ANY 12 -HOUR PERIOD OR UPON THE DIRECTION OF THE CITY ENGINEER, SILT AND DEBRIS SHALL BE REMOVED FROM CHECK DAMS. 11. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS INTO AREAS WHERE IMPOUND WATER CREATES A HAZARDOUS CONDITION. NECESSARY PRECAUTIONS MAY INCLUDE, BUT NOT BE LIMITED TO, APPROPRIATE PERIMETER FENCING OR A 24 -HOUR GUARD PREVENTING UNAUTHORIZED PERSONS FROM ENTERING THE BASINS, 12, PAVED STREETS, SIDEWALKS, AND OTHER IMPROVEMENTS SHALL BE MAINTAINED IN A NEAT AND CLEAN CONDITION, FREE OF LOOSE SOIL, CONSTRUCTION DEBRIS, AND TRASH. STREET SWEEPING OR OTHER EQUALLY EFFECTIVE MEANS SHALL BE USED TO CLEAN STREETS EXCEPT FOR THE REMOVAL OF FINE MATERIAL NOT OTHERWISE REMOVED BY SWEEPING OR OTHER MECHANICAL MEANS. 13. STANDBY CREWS SHALL BE ALTERED BY THE CONTRACTOR FOR EMERGENCY WORK DURING RAINSTORMS. 14. GRAVEL BAGS AND NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES OR REPAIR ANY DAMAGED EROSION CONTROL MEASURES WHEN RAIN IS IMMINENT. A STANDBY CREW SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. 15. ALL UTILITY TRENCHES SHALL BE BACK FILLED WITHIN 24 HOURS AND MUST BE BACK FILLED BEFORE THE END OF WORK DAY IF A 40 PERCENT, OR GREATER CHANCE OF RAIN IS PREDICTED. 16. A GRAVEL BAG SILT BASIN OR TRAP SHALL BE PROVIDED AT EVERY STORM DRAIN INLET TO PREVENT SEDIMENT FROM ENTERING THE STORM DRAIN SYSTEM. 9 Me NUNN N F21=91 ►N AB AGGREGATE BASE AC ASPHALT CONCRETE APN ASSESSOR'S PARCEL NUMBER BC BEGIN CURVE BCR BEGIN CURB RETURN BVC BEGIN VERTICAL CURVE C &G CURB & GUTTER CO CLEAN OUT CONIC CONCRETE EC END CURVE ECR ;:END CURB RETURN EOP °tDGE OF PAVEMENT EP END POINT EVC END VERTICAL CURVE EX EXISTING FIG FINISH GRADE FIL FLOWLINE FS FINISH SURFACE GV GAS VALVE HP HIGH POINT IE INVERT ELEVATION LF LINEAR FEET LP LOW POINT MB MAILBOX PCC PORTLAND CEMENT CONCRETE PCC POINT OF CONTINUOUS CURVE PP POWER POLE PRC POINT OF REVERSE CURVE PRV PRESSURE REDUCING VALVE PVMT PAVEMENT RET RETAINING RIM RIM ELEVATION SCO SEWER CLEANOUT SD STORM DRAIN SDG &E SAN DIEGO GAS & ELECTRIC SDRSO SAN DIEGO REGIONAL STANDARD DRAWING SMH SEWER MANHOLE STD STANDARD SWK SIDEWALK TB TOP OF BERM TIC TOP OF CURB TS TRAFFIC SIGNAL WM WATER METER WV WATER VALVE CHAINLINK FENCE MULCH 19' RETAIN 1.5' WALL LIMIT OF a 5' SIDEWALK PROPOSED F SIDEWALK PROPOS D � EASEMENT LEGEND ITEM SYMBOL CONCRETE CURB PROPOSED CONCRETE SIDEWALK CURB RAMP WITH TRUNCATED DOMES - - - -- PROPOSED SIDWALK UNDERDRAIN PROPOSED CONTOUR PROPOSED WALL PROPOSED PAVER BLOCK PROPOSED FENCE --- PROPOSED 3" MULCH EXISTING CONTOUR LIMITS OF WORK /DAYLIGHT LINE EXISTING PROPERTY LINE APPROVED EXISTING RIGHT OF WAY LINE - - -® EXISTING EDGE OF PAVEMENT UFt etr: EXISTING FENCE CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT EXISTING WATER VALVE MJ W EXISTING FIRE HYDRANT EXISTING WATER METER SEE ABOVE EXISTING SIGN PLANS PREPARED UNDER SUPERVISION OF DATE: % )G R.C.E. NO.: 71087 SEW J. WIDELSKI EXP.: 6/30/2017 EXISTING TREE SI -103 S' PARKING LANE -6" CURB ;OARSE SAND ;ET WALL FOOTING EXISTING 20' 2 RAISED 3. 10' QUEUEING LANE MEDIAN SHOULDER 2.0% 1.5% E. IMPROVEMENTS 1. A PERMIT SHALL BE OBTAINED FROM THE ENCINITAS SERVICES DEPARTMENT FOR ANY WORK WITHIN THE STREET RIGHTOOF -WAY AT NO COST TO THE CONTRACTOR. 2. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY. A PERMIT SHALL BE OBTAINED FROM THE ENCINITAS ENGINEERING SERVICES DEPARTMENT ANY WORK WITHIN THE STREET RIGHT -OF -WAY AT NO COST TO THE CONTRACTOR. 3. ALL UNDERGROUND UTILITIES WITHIN THE RIGHT -OF WAY SHALL BE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OR BERM, CURB, CROSS GUTTER AND PAVING. 4. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE DONE SHALL BE CONFORMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES, 5. NO PAVING SHALL BE DONE UNTIL EXISTING POWER POLES ARE REMOVED FROM WITHIN THE AREAS TO BE PAVED. EXISTING 20' R/W 3' SHOULDER 7' ASPHALT WALK 10' TRAVEL LANE TYPICAL SECTION VULCAN AVENUE STA 1+00 - 6 +00 PERVIOUS PAVER DETAIL F. IMPROVEMENTS 1. THE CONTRACTOR SHALL ENFORCE ALL MEASURES. THE CONTRACTOR SHALL CONSTRUCT AND MAINTAIN SAFETY DEVICES AS APPROVED BY THE CITY ENGINEER, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE, AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS, AND REGULATIONS. 2. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MONUMENTATION AND /OR ANY BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION SET BY A STATE OF CALIFORNIA LICENSED LAND SURVEYOR OR A REGISTERED CIVIL ENGINEER AUTHORIZED TO PRACTICE LAND SURVEYING. A CORNER RECORD OR RECORD OF SURVEY, AS APPROPRIATE, SHALL BE FILED BY THE STATE OF CALIFORNIA LICENSED LAND SURVEYOR OR REGISTERED CIVIL ENGINEER, AS REQUIRED BY THE LAND SURVEYORS ACT. 4. THE LOCATION OF EXISTING BUILDINGS SHOWN ON THESE PLANS ARE APPROXIMATE. 5. THE CONTRACTOR IS RESPONSIBLE TO POTHOLE AND LOCATE ALL EXISTING SUBSURFACE UTILITIES, PRIOR TO THE START OF DEMOLITION OR CONSTRUCTION. ANY EXISTING UTILITIES THAT REQUIRE REMOVAL OR RELOCATION SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY AGENCY PRIOR TO THE BEGINNING OF CONSTRUCTION. IF DURING POTHOLING THE CONTRACTOR DISCOVERS A POTENTIAL CONFLICT BETWEEN PROPOSED UTILITIES AND EXISTING UTILITIES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CITY. THE CONTRACTOR SHALL ALLOW AMPLE TIME FOR REVISIONS TO BE MADE TO THE PLANS TO AVOID CONFLICTS PRIOR TO THE START OF UTILITY INSTALLATION. 6. THE CONTRACTOR SHALL REQUEST MARKOUT OF EXISTING UNDERGROUND UTILITIES BY CALLING THE LISTED REGIONAL NOTIFICATION CANTER FOR AN INQUIRY IDENTIFICATION NUMBER, AT LEAST (2) DAYS PRIOR TO START OF ANY CONSTRUCTION. TRAFFIC CONTROL NOTES 1. TRAFFIC CONTROL SHALL BE IN ACCORDANCE WITH SECTION 7 -10 OF THE STANDARD SPECIFICATIONS AND APPENDIX "A" OF THE SAN DIEGO COUNTY REGIONAL STANDARD DRAWINGS (MIST RECENT EDITION). 2. THE CONTRACTOR SHALL MAINTAIN TRAFFIC FLOW IN BOTH DIRECTIONS IN CONFORMANCE WITH APPENDIX "A" OF THE SAN DIEGO COUNTY REGIONAL STANDARD DRAWINGS AND THE APPROVED TRAFFIC CONTROL PLAN DURING WORKING HOURS OF 7:30 AM TO 4:00 PM, MONDAY THROUGH FRIDAY, UNLESS OTHERWISE AUTHORIZED, NO WORK THAT OBSTRUCTS NORMAL TRAFFIC FLOW WILL BE ALLOWED DURING THE HOURS OF 4:00 PM TO 7:30 AM AND AT ALL TIMES SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS. THE PROJECT SPECIFICATIONS AND /OR CONDITIONS OF TRAFFIC CONTROL PLAN APPROVAL MAY FURTHER LIMIT WORKING HOURS 3. ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. 4. ALL TRAVEL LAMES WILL BE A MINIMUM OF 12 -FEET WIDE UNLESS OTHERWISE SHOWN. 5. TRENCH PLATES TO BE PROVIDED WITH SKID RESISTANT SURFACE. 6. THE CONTRACTOR SHALL NOTIFY ALL ADJACENT PROPERTY OWNERS AND TENANTS OF PROPOSED POSSIBLE TRAFFIC DETOURS AT LEAST 72 HOURS PRIOR TO COMMENCING WORK. THE PROJECT SPECIFICATIONS MAY CONTAIN ADDITIONAL NOTIFICATION REQUIREMENTS THAT SHALL SUPERSEDE THIS REQUIREMENT. 7. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES DURING PROJECT CONSTRUCTION. SAN DIEGUITO WATER DISTRICT NOTES (CONTINUED): BASIS OF COORDINATES 15. APPROVAL OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE A REPRESENTATION AS TO THE NAD 83 (1991.35 EPOCH) ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON - EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 16. ALL EXISTING FACILITIES WHICH MAY EFFECT FINAL DESIGN, I.E., LINE CROSSINGS, LINE PARALLELING, OR PROPOSED 1025 (ENC -25) 1024 (134WCCS1) 6 °X16° PCC FLUSH CURB CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSINGS WITHIN 10 FEET OF PROPOSED OR DEEPENED G -1 CURB WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND SEWER TO CROSS UNDER WATER MAINS UNLESS 2" SD. CITY OF ENCINITAS BRASS 2 1/2" DISK STAMPED "134WCCS1„ GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT. DISC STAMPED "ENC -25 L.S. IN SIDEWALK AT S.E. QUAD. OF VOID FILLER - 1/8" TO 3/8" NO. 8 APPROVED PERVIOUS 17. WATER CONNECTIONS TO COMMERCIAL DEVELOPMENTS SHALL HAVE AN APPROVED BACKFLOW DEVICE INSTALLED TO THE 7322" IN WELL MON. IN THE LEUCADIA BLVD. AND ORPHEUS AVE. ( ) DISTRICT'S SATISFACTION AND CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASC) STANDARDS. BACKFLOW DEVICES MIDDLE OF THE INTERSECTION OF N 1968854.614' AGGREGATE IN VOIDS PAVERS W/ MIN. 3/8 VOID ARE TO BE INSTALLED DIRECTLY OUTSIDE CITY OR COUNTY RIGHT -OF -WAY OR OUTSIDE WATER DISTRICT EASEMENT. REPAIR, S. EL PORTAL ST. & LA MESA E 6242001.192' BEDDING COURSE - 2" THICK OF MAINTENANCE AND ANNUAL TESTING OF BACKFLOW DEVICE ARE RESPONSIBILITY OF OWNER. AVE. RECORD OF SURVEY 18416 N 1965570.266' 1/8" TO 3/8" (NO. 8) AGGREGATE rf r; 7 l:'i -,Z7A 18. MINIMUM HORIZONTAL SEPARATION OF 10 FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC VAULTS. E 6239988.375' RECORD OF SURVEY 18416 CHOKER COURSE - 4° THICK OF \ / \/\ 19. UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 3/8" TO 1/2" (NO. 57) CRUSHED ROCK 2„ \ \ \ \ /� \ \ / / \ \� 20. CONTRACTOR AND DEVELOPER ARE RESPONSIBLE TO RELOCATE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, MIN. 6" THICK OF 314" 4" �j / \ / / \ / / \// VALVES, VALVE BOXES, ETC.) THAT ARE EFFECTED BY THEIR PROJECT. (NO. 2) CRUSHED ROCK - �6 „ / \ / \ / \ \ / \\ 21. CONTRACTOR TO SUPPLY DOCUMENTATION SHOWING THAT ANY ASBESTOS WATER PIPES REMOVED FROM THE GROUND WERE DISPOSED OF IN A MANNER ACCEPTABLE TO THE SAN DIEGO COUNTY WASTE DIVISION. SOIL SUBGRADE DEFLECTION COUPLINGS AND 22. USE THE US INTEGRAL BELL FEOND PIPE FOR 14URVEDMALIGNME NTSO N BOTH HORIZONTAL L AND HVERTIICALHDIRECTIONS. DO NOT BEND PIPE //�\ / BETWEEN COUPLINGS. SAW CUT INTEGRAL BELL END OF STANDARD PIPE AND BEVEL END FOR USE WITH DEFLECTION BENCHMARK �i� \ \ /� \ \ /�� /� /i COUPLINGS. USE 9.5 -FOOT PLAIN END PIPE LENGTHS WITH DEFLECTION COUPLINGS FOR ALL RADII BETWEEN 140 FEET TO 270 FEET. USE 19 -FOOT PIPE LENGTHS WITH DEFLECTION COUPLINGS FOR ALL RADII BETWEEN 270 FEET TO 560 FEET. USE 1025 (ENC -25) AND INTEGRAL BELL END PIPE LENGTH JOINED TOGETHER WITH A 19 -FOOT PLAIN END PIPE LENGTH TO FORM A CHORD. USE DEFLECTION COUPLINGS ON EACH END OF THE CHORD AND CONTINUE THIS COMBINATION THROUGH THE CURVED ALIGNMENT 2' CITY OF ENCINITAS BRASS DISC - NOTES: FOR ALL RADII BETWEEN 560 FEET TO 1,150 FEET. PIPE LENGTHS SHORTER THAN 9 FEET WILL NOT BE USED UNLESS STAMPED ED "ENC -25 L.S. 7322" IN WELL ` }' -ALL AGGREGATE MUST BE CLEAN /WASHED AND FREE OF FINES (SAND SPECIFICALLY AUTHORIZED THE BY THE DISTRICT'S REPRESENTATIVE. ., SILT, ETC.) �,y NON. IN THE MIDDLE OF THE ORTAL ST. & -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED �o jpSEpy 1 CALIFORNIA IR STATE LAW ASSEMBLY EE WATER BILL AB-1953 IS EFFECT REQUIRING TTHAT NO INEACOMPLIAS EW USED TH S THE CONSTRUCTION -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE ��� No 2Q SHALL REQUIRE ALL MATERIALS TO BE NO -LEAD BRASS PARTS. RE MESA AVE. -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED ti RECORD OF SURVEY 18416 -< -. w mw - SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL'- SUBDRAIN MAY BE REQUIRED 2 4 C79U87 , 2.ALL COPPER TUBING USED FOR AIR RELEASES, BLOW OFFS, AND SERVICES SHALL BE PROVIDED WITH CATHODIC ELEV. 60.601 FEET ,t EXP. `=� PROTECTION IN ACCORDANCE WITH WC -17 OR WC -18. DATUM: NAVD 88 FCAIUP` 3. WATER SERVICES TO BE ABANDONED THAT ARE CONNECTED TO PIPELINES THAT WILL REMAIN IN SERVICE SHALL BE NNECTED DETAIL A PUG INSTAL LED; TORHBECAABANDONIEOD ASODIR CTEDLBY THE SDWD INSPECTOR. STOP REMOVED AND SHALL HAVE A BRASS CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT "tJlliNtU bY: UFt etr: ` "t` "t" �r: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. MJW MJ W ED SEE ABOVE HORIZONTAL: NONE VERTICAL: NONE %A%m. ENGINE M'S NAME DATE PLANS PREPARED UNDER SUPERVISION OF DATE: % )G R.C.E. NO.: 71087 SEW J. WIDELSKI EXP.: 6/30/2017 RECOMMENDED: APPROVE[h DATE: -7--�°�. �!.;�% DATE: % 8 /L R.C.E._q � R.C.E. 27 IMPROVEMENT PLAN FOR: PAUL ECKE CENTRAL IMPROVEMENTS 256 -301 -01 WORK ORDER NO: CS16D SI -103 SHEET 2 OF 5 g. ....... —. __w, �. _ _ PVI ELB: 68.07' _ _ . ____. _.r. (,. ,._._....._._ PVI, STA. 4.98.28 . TA 4 +LIU UU PVI ELE 70.48' PVI STA 2 +15 i ,..._. PVI STA. 3 +00.00 PVI STAN 3 +50.00 I )• ' PV ELEV. 68.65 �� 20'� PVI ELE : _69.14' PVI_ ELE/: 69.84' PVI ELE 70.24 .. - 1, I 1 g 1 1 UO.,...x......_-___ -� ...... .... ...... ....... ..___._._._..._......._.a.,.._� __�_ .... _... .._,.___._ .._..__,....._. ............ . _..FTC _�.1._._.m _.,.. _- ,..,.,.�,,.IIf .. _.... -. ._ _.._.._. �.L... -'i � -_..1� ___. _._..,..:... _._..,_.�._'.,�'t �._.� �....._ - - -. ._- _.. O N O J M O h M N M 1- M M M O M J M O N M O O 1 N O b O O r . 00 �to 07 O O 7 111- + J w Z; OD M c6 T �N r- OIN a) +10 M t.. + O ._ Ml� Li - -. (a) c0 M W Q�O �� N�. 04 W ��_ — � w > F > __ -. U) m N W fn W -� 57% �� 0 <0 �' �� � > �m �w 080% 0,24% - .. �... .. .._.v- t,�1J�....N..m..._ �_. A -... M v>w => —1.48% u) m _ ®x m ON +0 3 +00 4+ 5 +00 CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT DESIGNED BY: DRAWN BY: CHECKED BY: MJW MJW ED ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. Ai - u w miw 91R416 PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APPROVE IMPROVEMENT PLAN FOR: PAUL ECKE CENTRAL DATE:�I� SEE SHEET 2 HORIZONTAL: 1" =20' IMPROVEMENTS SD -103 VERTICAL: 1" = 5' C /►(sNLe 9e�er` 6k&, 14 R.C.E. NO.: 71087 256- 301 -01 ENGINEER'S NAME DATE MATTHEW J. WIDELSKI DATE: _7 - 8 •I% DATE: % $ R EXP.: 6/30/2017 R.C.E. � R.C.E. /Z 7Y WORK ORDER NO: CS16D SHEET 3 OF 5 CUR- B_DATA J JABLE BEARING OR DELTA L LENGTH R RADUIS N NOTES 7 9 . � � - - -- -_._ . .�,� C CURB � �PPER G G=1 a ._ ❑2 A A = = 57 °15'50" 5 5.71' 1 10 6 6" C CURB P PER G G -1 ❑3 N N27 °541 24 11 W 3 34.95' - - -- 6 6" C CURB P PER G G -1 ® 0 0 = = 50 °0'0" 6 6.98' 1 10 6 6" C CURB P PER G G -1 ❑5 N N67 °54'24 "W 6 6.99' - - -- 6 6" C CURB P PER G G -1 F-611 A A = = 50 °0'4" 3 3.49' 5 5 6 6" C CURB P PER G G -1 IT N N27 .54'24"W 1 198.74' - - -- 6 6" C CURB P PER G G -1 ® A A = = 60 °0'2" 2 2.62' 5 5 6 6" C CURB P PER G G -1 ❑9 N NO2 °05'36 "E 3 35.34' - - -- 6 6" C CURB P PER G G -1 0 0 0 = = 60 °0'0" 5 5.24' 1 10 6 6" C CURB P PER G G -1 11 N N27 °54'24 "W 1 16.04' - - -- 6 6" C CURB P PER G G -1 BY: DRAWN BY: CHECKED BY: MJW MJW ED ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. Ai - u w miw 91R416 PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED: APPROVE IMPROVEMENT PLAN FOR: PAUL ECKE CENTRAL DATE:�I� SEE SHEET 2 HORIZONTAL: 1" =20' IMPROVEMENTS SD -103 VERTICAL: 1" = 5' C /►(sNLe 9e�er` 6k&, 14 R.C.E. NO.: 71087 256- 301 -01 ENGINEER'S NAME DATE MATTHEW J. WIDELSKI DATE: _7 - 8 •I% DATE: % $ R EXP.: 6/30/2017 R.C.E. � R.C.E. /Z 7Y WORK ORDER NO: CS16D SHEET 3 OF 5 } 60 1+00 2 +00 11 4+ 5 +00 CHANGE NO. DESCRIPTION APPROVED DATE 0 m AS -BUILT W utiI �Y: ` "t` t" "Y: ENGINEERING DIVISION APPROVALS EX AC DRAWING NO. w (O EX PAVEMENT BERM 70 -- + J •• z w RW ww 46 m W- — EX WOOD FENCE 9/ SEE SHEET 2 HORIZONTAL: 1" = 20' VERTICAL: 1" = 5' -CONNEvcPTOcXPcC CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT "ts "' "t" �Y: utiI �Y: ` "t` t" "Y: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. INITIALS IN INITIALS AS - SUILT ww 46 MJ 9/ SEE SHEET 2 HORIZONTAL: 1" = 20' VERTICAL: 1" = 5' 9/9 PLANS PREPARED UNDER SUPERVISION OF DATE: pla�>:ai Coq qVA / ` / ' R.C.E. NO.: 71087 ,r+ MATTHEW J. WIDELS�KI EXP.: 6/30/2017 RECOMMENDED: APPROVE .4 / R CTE. R CDATE: E. 7 t7y` IMPROVEMENT PLAN FOR: PAUL ECKE CENTRAL IMPROVEMENTS 256- 301 -01 WORK ORDER NO: CS16D SI -103 ENGINEE S NAME DATE SHEET 4 OF 5 CONSTRUCTION NOTES 01 EXISTING SIGN TO BE REMOVED 122 INSTALL NO LEFT TURN SIGN PER R3 -2 OF MUTCD (�3 INSTALL TYPE Q OBJECT MARKER PER CALTRANS STANDARD PLAN A73A ® BEGIN PAINTING RED TOP OF CURB TO INDICATE "NO PARKING" 0 END PAINTING RED TOP OF CURB TO INDICATE "NO PARKING" ® REFRESH WHITE EDGE STRIPING LINE PER A20B CALTRANS STANDARD PLAN (L =300 FT) 7O MUTCD LEGENDS ARE TO BE PLACED IN THERMO PLASTIC NOT PAINT. SIGNAGE WILL l BE IN DG -3 REFLECTIVE TYPE SHEETING WITH BREAKAWAY POSTS PER SDRSD CHANGE NO. DESCRIPTION APPROVED DATE BENCHMARK SCALE AS -BUILT DESIGNED BY: DRAWN BY CHECKED ar: ENGINEERING DIVISION APPROVALS CITY OF ENCINITAS - PUBLIC WORKS DEPARTMENT DRAWING NO. INITIAL IN INITIALS SEE SHEET 2 HORIZONTAL: 1" = 20' VERTICAL: NONE PLANS PREPARED UNDER SUPERVISION OF DATE: 7/71 G V• /�i_' R.C.E.NO.:71087 MATT EWJ. WIDELSKI EXP.: 6130/2017 RECOMMENDED: APPROVED- K DATE: DATE: ?ZA�z R.C.E. / R.C.E. /eWl IMPROVEMENT PLAN FOR PAUL ECKE CENTRAL IMPROVEMENTS 256- 301 -01 WORK ORDER NO: CS16D SI-103 ENGINES S NAME DATE SHEET 5 OF 5