Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
7929
CITY OF ENCINITAS COMMUNITY SERVICES DEPARTMENT RANCHO SANTA FE ROAD VVALL NEIGHBORHOOD ENHANCEMENT U CONTRACT NO. : CS01 -05 con RANCHO SANTA FE ROAD 2/2001 PROJECT NO. : CMP-01B BETWEEN CAMINO DEL NORTE & LONE JACK SHEET INDEX VICINITY MAP GENERAL NOTES SHEET NO. SHEET TITLE v a (1) SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A T-1 TITLE SHEET i t 0 Qv RIpGE DIGALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT D-1 EXISTING CONDITIONS - DEMOLITION PLAN t� �rysr ¢ v c,�° TO EXCAVATE WILL BE VALID. FOR YOUR DIGALERT I.D. NUMBER C-1 CONSTRUCTION PLAN Q v�� CALL UNDERGROUND SERVICE ALERT AT 1-800-422-4133 TWO C-2 CONSTRUCTION DETAILS c M m �� WORKING DAYS BEFORE YOU DIG. L-1 PLANTING PLAN co Lry v v� ® CONTRACTOR SHALL PROVIDE FOR ALL CITY REQUIRED TRAFFIC CONTROL FOR ALL WORK WITHIN THE RIGHT-OF-WAY. P ROJ E C SITE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN TO THE NVISTADR try TRAFFIC ENGINEER A MINIMUM OF SEVEN (7) DAYS PRIOR TO BEGINNING WORK FOR CITY REVIEW & APPROVAL. 0 cn L NE ® A PERMIT SHALL BE OBTAINED BY THE CONTRACTOR FROM THE F ✓ACkR� CITY OF ENCINITAS ENGINEERING DEPARTMENT FOR ANY WORK o WITHIN THE STREET RIGHT-OF-WAY. NO FEE WILL BE CHARGED FOR PERMIT. L n s VI/VG o ° IGS to °' EL C w tllb W ��o 0 MINO AFC NO TF S LL W �2 U) o PE grySr 9rjyS 0 411 411 -..! NORTH T �,ypVl <lv 2 OJ rse wytSP grySr C4, a 0 � � Z � z PROJECT CONSULTANTS DECLARATION OF RESPONSIBLE CHARGE W W g LL LL *d PELA I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED w RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS F- ca 637 ARDEN DRIVE AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. a Z N v ENCINITAS CALIFORNIA 92024 W (760) 944-8463 �N t H I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF ENCINITAS IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES Z Z FOR PROJECT DESIGN. LU (PELA, 637 ARDEN DRIVE, ENCINITAS, CALIFORNIA 92024, (760) 944-8463 a= Q o BY: MICHAEL G. ELLIOTT DATE: 11/08/2000 W o 0 Z LICENSE NO. : 2011 EXP. DATE: 04 130/01 O p W =o Uo g J = •• .. Z Z ui Zm w Z V = VJ a O W� OD IL Z a tai = ; OLIVENHAIN TOWN COUNCIL REVISIONS BY DATE BENCH MARK APPROVALS RECOMMENDED BY DATE APPROVED BY DATE CITY OF ENCINITAS COMMUNITY SERVICES DEPARTMENT SHEET NO. a APPROVED Cit OlivinhainTown Council 2.14.01 DESCRIPTION: WATER DEPARTMENT "_ ^``, I SHEET TITLE / DESCRIPTION a ENCINITAS FIRE PROTECTION DISTRICT TITLE SHEET S I=0 023-L N I A&Itpl LOCATION: ENGINEERING DEPARTMENT BY: RECORDED FROM: 31k$ ( COMMUNITY DEVELOPMENT DEPARTMENT _ ,� Z i DATE COMMUNITY SERVICES DEPARTMENT I 4 ELEVATION: DATUM: OLIVENHAIN MUNICIPAL WATER DISTRICT .G i SHEET T-1 OF 6 D:\Encinitas\Rancho Santa Fe Wall\Title Sheet.dwg 1 i i 1 , w_ {a ,--.3.4>6 ;R E t ` � E 1 F _ 4 5 { AAI I R tW...... _......__ . .... _. ......................... ...._..... WON WE IMMUNE IN 7 16" L CML� C WATE Nt` 8 i.; I 6 1 za° 41 2 5 I I I I 6 I I 12 "s' { ' 16" STL CMLC WA! RLiNE 16" STL CMLC V �I� RANCHO SANTA E ROAD c! it � j T 0 '00 SF=qo 'x C0 12" STL CMLC WATERLINE / e o c -- - E—, a �- �•.� I— c> ,E o .....R A W-. ,. .... __ :-..RfW.....,. LL LL j ry i z f Q tt D ER 18" ! = 20, 1 1 N { EEP 1 Du i U) o r W W I 1 ° 1 y. { I z a j I E � ` v V _Z Z r_.,0N5TRUGTI 0N NOTES: O EXISTING CONCRETE RETAINING WALL TO REMAIN. PROTECT IN ® EXISTING IRRIGATION CONTROLLER TO REMAIN. PROTECT IN d PLACE. SEE SHEET 0-1 FOR NEW STONE FACING INSTALLATION. PLACE. od UJI O EXISTING MULCH TRAIL TO REMAIN. PROTECT IN PLACE. 10 EXISTING GUY-WIRES TO REMAIN. PROTECT IN PLACE, H 3 EXISTING STREET CURS S GUTTER TO REMAIN. PROTECT IN PLACE. CONTRACTOR SHALL REMOVE S DISPOSE OF EXISTING WALL V I I W VINES IN A LEGAL MANNER. H 4 EXISTING CONCRETE SCALE ® TOP F NA LL W LL TO REMAIN. NORTH 12 PROTECT IN PLACE. CONTRACTOR SHALL COORDINATE RELOCATION OF EXISTING DRIP V IRRIGATION VALVES, TUBING, AIR RELIEF, FLUSH VALVES, S ALL Q O EXISTING CHAIN LINK FENCE TO REMAIN. PROTECT IN PLACE. OTHER IRRIGATION EQUIPMENT ® BASE OF WALL W/ CITY AS W REQUIRED TO INSURE THAT EQUIPMENT 15 CLEAR OF NEW STONE © EXISTING STOP SIGN TO REMAIN. PROTECT IN PLACE. VENEER S ACCE5515LE WITH NO OBSTRUCTIONS. CITY WILL V PERFORM RELOCATION WORK. y O EXISTING PARK SIGN TO REMAIN. PROTECT IN PLACE. p z® EXISTING IRRIGATION EAGKFLOW TO REMAIN. PROTECT IN PLACE. SCALE: 1'°=20' 20 0 20 40 60 a OLIVENHAIN TOWN COUNCIL "AS-BUILT" APPROVED z LANDSCAPE ARCHITECTURE BY: to m BY' PELA PLANNING ��� DATE: 4c 637 Arden Drive,Encinitas,CA,92024 °A 1H I (760)944-8463 DATE RCE: EXP: va REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE ENCINITAS FIRE PROTECTION DISTRICT DESIGNED BY 7 DRAWN BY CHECKED BY APPROVALS CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT DRAWING NO. a Cit Clivenl-Eo n Town Cuuncil '.14,C« BENCHMARK: OC-0073 PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED IMPROVEMENT PLANS FOR: CL C W DESCRIPTION: CHISELED SQUARE IN TOP OF DATE: 11!2000 RANCHO SANTA F E ROAD WALL N W CONCRETE HEADWALL HORIZONTAL 1'=20' LOCATION: RD&E60TSLY LCAMINODELNORTE BY: MICHAEL G. ELLIOTT R.LA.NO.: 2011 BY: BY; NEIGHBORHOOD ENHANCEMENT SI=0023®L pzo ELEV: 119.467 DATUM: VERTICAL N/A DATE (NAME) EXPO 4130/01 DATE: -�°O� EXISTING CON DITIONSIDEMOLITION PLAN SHEET D-1 OF �a. -t.A c: , rEuiita.7\IC:neh S: `,. 1 Fe 'sfrali' Ci-"I . IsAac c«e11 cornp corn 1 i,' 312000 NOTE : ELEVATION 15 PROVIDED FOR GONTRAGTOR REFERENCE ONLY. TOP OF WALL GONTRAGTOR SMALL FIELD VER I FY AREA OF WALL FOR MATERIAL TAKE-OFFS. TOP OF CURB SCALE: 1"=10' pm M19 TOP OF FOOT I NCP 10 0 10 20 30 Lu 11 . j I � ` ti 7 t, ll.i i W ._,..._,......,_..__._ .... _,., Lor.. _ _, R/W- i ............. U 4 2 2 aa)) of c=::::A% i 7 uo n RANCH® SANTA NT R®AD i7.p.�U A M w 1 F b L U LL U @ ffi6ffi@@ ffi8@ ffi8@ 9ffiIBffi8ffi@@@ 8@ 8@ 88@@ ffi0@@ 8ffi@ 8ffi@@@ 88@@@ 8tli@[tl@ ffiY@ 8ffi808@ 9@@ tl8ffi8@ 8ffi@@@ tl88@ ffi09ffi98ffi@ 8@@ 8@@ 8@@ 0ffi @8tlffii @88[88885ffiffii @8tl§8 @8 @889ffi@ 888@ 88888@@ tl@ ffi@ E@ a@ 8888ffi @8tllW8 @ffi @ @ffi @8ffi @88 @tlffi&tld@ @8 S i t V Q . Q i i I 1 L3 1 z NORTH SEE ST c,2 FORS IS FLAN g CONSTRUCTION NOTES : O CONTRACTOR SHALL GLEAN/PREPARE WALL SURFACE TO U3 CONTRACTOR SHALL INSTALL LODGE POLE FENCE PER DETAIL 'A', F SCALE: 1"=20' RECEIVE STONE VENEER AS REQUIRED PER SPECIFICATIONS & SHEET 0-2. SEE SECTION 'A', SHEET 0-2. V MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR SHALL 0 SANDBLAST EXISTING WALL SURFACE TO REMOVE ANTI-GRAFFITI ® END OF FENCE ® 6 FROM IRRIGATION CONTROLLER. _ 20 0 20 40 60 COATING. CONTRACTOR 15 ADVISED THAT THE EXISTING WALL 15 U CONSTRUCTED W/ CORRUGATED TEXTURE ON THE FACE. O END OF FENCE ® 6" FROM FACE OF SIGN POST. CONTRACTOR SHALL FILL VALLEYS OF CORRUGATION PER a SPECIFICATIONS. INSTALL STONE VENEER ON ALL EXPOSED © CONTRACTOR SHALL REPAIR TRAIL SURFACE TO CONDITIONS Ill SURFACES OF EXISTING CONCRETE RETAINING WALL (FACE, TOP, PRIOR TO BEGINNING WORK. INSTALL ADDITIONAL MULCH AS a \ SIDES) U51N6 JOINTLE55/DRY STACKED METHOD PER REQUIRED AND PROVIDE SMOOTH, COMPACTED SURFACE. V MANUFACTURER'S SPECIFICATIONS 8 RECOMMENDATIONS 4 N PROJECT SPECIFICATIONS. STONE SHALL BE MOUNTAIN BLEND CONTRACTOR SHALL COORDINATE RELOCATION OF EXISTING DRIP z SHADOW ROCK AS MANUFACTURED BY STON€GRAFT INDUSTRIES TUBING, AIR RELIEF VALVES, FLUSH VALVES 4 ALL OTHER (760) '736-3232. CONTRACTOR SHALL PROVIDE 3' SQUARE IRRIGATION EQUIPMENT AS REQUIRED TO IRRIGATE NEW VINES SAMPLE OF MATERIAL FOR CITY REVIEW 4 APPROVAL. PLANTED PER PLANTING PLAN W/ CITY. CITY WILL RELOCATE ALL g CONTRACTOR SHALL MAINTAIN WALL DRAINS IN CLEAR WORKING EQUIPMENT 50 THAT THERE ARE NO OBSTRUCTIONS WITH NEW' W d OLIVENHAIN TOWN COUNCIL ORDER WHERE THEY OCCUR- STONE WORK SHALL CONFORM TO STONE VENEER. CITY WILL ADD DRIPPER TUBING/EMITTERS AS I EXISTING WALL EXPANSION JOINTS. SEE SECTION 'A' 8 DETAIL 'C', REQUIRED TO INSURE ALL NEW VINES ARE PROPERLY IRRIGATED. APPROVED 5HT. G-2. ONE EMITTER SHALL BE INSTALLED ® EACH VINE PLANTING. 'SAS-BUILT"' ' LANDSCAPE ARCHITECTURE PLANNING REMOVE EMITTERS 4 PROVIDE PLU65 AS REQUIRED WHERE VINES a O AFTER COMPLETION OF STONE WORK, CONTRACTOR SHALL ARE REMOVED 4 NO LONGER NEEDED. EMITTER TUBING SHALL BE Z BY: 6 INSTALL PLANTING VINE GABLES OVER FACE OF WALL PER INSTALLED BELOW TRAIL MULCH. INSTALL TUBING STAPLES ® 6' BY: 637 Arden Drive,Encinitas,CA,92024 DATE: I- (760)9448463 DATE DETAIL 'B', SHEET 0-2 @ LOCATIONS FOR DISTIGTU5 PER SHEET MULCH.- MA . SPACING 4 AS REQUIRED TO HOLD TUBING BELOW ef! W� 3 RCE: EXP f'er REVISIONS APPROVE DATE REFERENCES DATE BENCH MARK = m vid 'Cili.:8r; airs TUVYr'i CO ,;)�;; 2.1 SCALE ENCINITAS FIRE PROTECTION DISTRICT DESIGNED BY DRAWN BY CHECKED BY ual APPROVALS CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT _ a� BENCHMARK: OC-0073 DRAWING NO. PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED W „ DESCRIPTION: CHISELED SQUARE IN TOP OF IMPROVEMENT PLANS FOR: CONCRETE HEADWALL HORIZONTAL DATE: 11/2000 RANCHO SANTA FE ROAD WALL a0 LOCATION: 23'WESTERLY OF RANCHO SANTA FE AS NOTED V Z RD.8 60'S'LY EL CAMINO DEL NORTE BY: R.L.A. NO.: 2011 MICHAELCa(NAME)TT BY: BY: NEIGHBORHOOD ENHANCEMENT SI=0023=L clW ELEV:119.467 DATUM: VERTICAL NIA DATE (NAME)) EXP. 4/30101 DATE: o Z Z CONSTRUCTION PLAN �a PO cry d:\Encinitos\Roncho i<�ntn : v c11 ,r— i . i cle':I o `I /08/2000 SHEET OF LEGEND Ot WALL PER PLAN. NOTES O 1/4" STAINLESS STEEL CABLE — PASS THROUGH EACH EYE A. WHERE TOP OF WALL OCCURS, CABLE & EYE BOLTS SHALL BOLT. INSTALL 3 PER VINE (TYP). FINISH O 2' BELOW TOP OF WALL 3/8" STAINLESS STEEL EYE BOLT. ROTATE TO HORIZONTAL B. INSTALL ALL EYE BOLTS PLUMB & LEVEL W/ EACH OTHER. POSITION WHERE TURNBUCKLES ARE NOT USED, TO ALLOW C. PROVIDE CABLE LOOP ® TURNBUCKLES BY TURNING CABLE ON CABLE TO PASS THROUGH. SEE DETAIL TO RIGHT. INSTALL ITSELF & CLAMPING CLOSED W/ (2) 3/8" STAINLESS STEEL ® 24" O.C. VERTICAL, 12" O.C. HORIZONTAL (TYP). CLAMPS. PROVIDE & INSTALL 3/8" STAINLESS STEEL EYE TO EYE ® LEAD ANCHOR (EXPANSION SHIELD). TURNBUCKLES ® TOP & BOTTOM EYE BOLT LOCATIONS & EVERY — 10 O.C. MAX. STRETCH CABLE TO PROVIDE APPROPRIATE O FINISH GRADE. TENSION. VINE OR ESPALIER (SEE PLANTING PLAN, SHEET L-1) — SECURE VINE/ESPALIER TO CABLE W/ NURSERYMANS TAPE. OO ROOTBALL — PLANT PER SHRUB PLANTING DETAIL ® UNDISTURBED NATIVE SOIL. ' s PROVIDE BOLT LENGTH •` '... :,.. ' r 1 AS REQUIRED TO O9 3/8" STAINLESS STEEL TURNBUCKLE. SECURELY MOUNT `< CABLE TO WALL. ee. 3/8" STAINLESS STEEL CLAMP (TYP. OF 2), 3 O LOOPED STAINLESS STEEL CABLE TO ATTACH TO TURNBUCKLE. e.; LEGEND SEE DETAIL TO RIGHT FOR EYE BOLT & TURNBUCKLE CONNECTIONS. ° .' < ° 4 (D CHAMFER OR DOME TOP ON POST. J 3-1/2" LODGE POLE RAIL INSERTED INTO POST. 1 TYPICAL OF 2. �2�2 ' S 2 3� 5" DIAMETER LODGE POLE POST, WITH SIDES ? I" _ t r-^--{ . ROUTED TO RECEIVE RAILS. SPACE POSTS 8' O.C. w N MAXIMUM. END POST SHALL BE ROUTED TO RECEIVE 4 + 3 RAIL ON 1 SIDE ONLY. a N O FINISH GRADE. a l ' '�0 < ' 10 O SUB—GRADE. COMPACT ® POST TO 90%. io 4 NOTES: FENCE MATERIALS SHALL BE TREATED LODGE POLE _ EYE BOLT 10 AS MANUFACTURED BY SVC AS AVAILABLE THROUGH TURNBUCKLE DETAIL 5 C&E LUMBER COMPANY, (909) 626-3591 (CONTACT RICK RUSSI) OR CITY APPROVED EQUAL. a ) I 2 INSTALLATION SHALL BE BY CONTRACTOR Ld 5 N EXPERIENCED IN THE INSTALLATION OF LODGE POLE FENCING. III L CONTRACTOR SHALL INSTALL ALL POSTS PLUMB. MAI F=1 I I I I I 7 EXISTING CONCRETE SWALE TO REMAIN. POSITION POSTS SUCH THAT RAILS FIT SNUG SO AS PROTECT IN PLACE NOT TO BE EASILY REMOVED. X11 9111 —III- . � - I�II�II X11= 8 II- cv ILJJ1 ,111�I 1�J��11=111111 CONTRACTOR SHALL INSTALL CORNER STONES @ U - -ut=ut-lit JI�lL�J1L� ALL WALL CORNERS. I ( I—III—III—I LODGE POLE FENCE VINE CABLE I I f—I i I=I i I-I i►=i E - 0 o EXISTING WALL _ ` III—III—I No STONE VENEER. CONTRACTOR SHALL PREPARE I I—III—III 0 NALL SURFACE PER SPECIFICATIONS 4 III—III-1 U) m MANUFAGTURER'5 RECOMMENDATION5. 5AND I (—III—III BLAST NALL SURFACE TO REMOVE _ ANTII-GRAFFITI COATING. FILL CORRUGATED I I (—I I I—) U) o FACE OF NALL TO PROVIDE SMOOTH, FLAT I (—III—I EXISTING CONCRETE NALL. SURFACE PER SPECIFICATIONS. INSTALL STONE 1O III=III—I VENEER USING JOINTLE55/DRY-STACKEID METHOD. I III_I I STONE VENEER PER PLANS I SPECS. AFFIX M STONE VENEER TO NALL U51N6 MORTER/CEMENT MIX PER SPECIFICATIONS 8 III I I (=III- 'S O I=I I OMORTAR/CEMENT PER PLANS $ SPECS. MANUFACTURER RECOMMENDATION5. SEE I=III DETAIL 'G', SHEET G-2. II—II(—I ( I O O.C. EVERY 3RD COURSE.PEGS. INSTALL 12" —1 I I—III-1 III—III—III CONTRACTOR SHALL INSTALL LODGE I—I I I—I L E I POLE FENCE PER CONSTRUCTION NOTE III—III—III z #5, SHEET 0-1 8 DETAIL 'A', SHEET 0-2. I=III=III=1 I z z III—III—III a 2 EXISTING WALL EXISTING CURB PROTECT IN PLACE. g 3 1 III—III—III CONCRETE FOOTING atf a __ __ _ w 4 —III— III—III—III III—III—__III=III— W I I—I I I I 1=1 I I—I I I_I I I III—III 11—III—III—III—III _ III—I I =i I — A III—III II �o d a III—III II. . . I 4 _ .4 ;,,III,;,,III a III—I I I—III—III—III q FACE OF III=1 I I . III=III=1 I I=1 11= N STONE VENEER _ EXI5TIN6 =III o III=III, , III, ,III, , III dd FINAL PATH NIDTH WILL BE WALL I i I—III d III– APPROXIMATELY 5'1 ONCE STONE _ VENEER 8 VINES ARE INSTALLED. W 3'-II" III—III _III— a s OLIVENHAIN TOWN COUNCIL 5'-10" I I I III I I III I I I ( I I I I ( I I I1- a _ "AS-BUILT" � LANDSCAPE ARCHITECTURE APPROVED .,, III ,;, I I I,;,I I (, ,I I ( ,;,� BY: rn < BY: SECTION 'A' DATE: 12 PLANNING PELA 637 Arden Drive,Encinitas,CA,92024 SCALE 1/2 = 1 RCE: EXP: ~ (760)944-8463 RTE DESIGNED BY III DRAWN BY I CHECKED BY C REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE ENCINITAS FIRE PROTECTION DISTRICT APPROVALS CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT DRAWING NO. Q Ol , a 2,1�•01 BENCHMARK: OC-0073 PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED IMPROVEMENT PLANS FOR: W . El:v! .. ii'dE'r? ?r 3f'k �i>W(? COE�:rk4ii a. t DESCRIPTION: CONCRETE HEADWALLOP OF HORIZONTAL NIA DATE: 1112000 RANCHO SANTA FE ROAD WALL y LOCATION: 23'WESTERLY OF RANCHO SANTA FE R.L.A. NO.: 2011 RD.&60'S'LY EL CAMINO DEL NORTE BY: MICHAEL G. ELLIOTr BY: BY: NEIGHBORHOOD ENHANCEMENT SI-0O23®L z � ELEV: 114.467 DATUM: VERTICAL N/A DATE (NAME) EXP. 4/30101 DATE: CONSTRUCTION DETAILS SHEET C-2 OF g � PELA dAE ;6nIItas\`ianchi;,, Santo ;:e WaI1\1C-2Awg deli Corr:r 11/0811/2000 L.�Y i fl + 4 F J t i if II p 9' H' VINE5 ® BOTTOM OF O.G. TYPICAL WALL SHALL BE PLANTED IMMEDIATELY ADJACENT TO THE FACE OF WALL. TYPICAL. RANOHO SANTA FE ROAD 0 Of t,;; M1LL t € i , f �: 8k4kkkkk�kffiBkkkk[kkk6kkkkkkkkkkkkkkikHffi8kkkkffikffikkFffikkkkkffikkkkkkkkkkkkkkkkkkkkkkkkffiffikktlkk'k8ffi5kffiffi9ffi89Hk Hffi5kE6kffikkkkkkkk0ffikffi88ffi8kffikWkkkkEkk'4EkEkkkkffikel Fkkkffikffikffik89 @BikSYtffi8ffi99Gk9SkBkB 3 i t T-T t i E 1 Il v, r l ° j � . ; y I _ - 1 ',? Z I Lo I I j 1 1101 I I : ► ! ALL O < SHOM ON THIS SHEET KLL 5 FLAB ' O M B E°r C, 17`r . SHEET 15 I NOLU�E� 0 CL zvo�Tx 50 THAT OONTfiRAOfiO GAN LOGATE � Lo II LL U_ SCALE: 1°'=20' INSTALL VINE � L A ES . Q) W 20 0 20 40 60 � o ° ° 1 ° 2 LEGEND OO ;cd= at ' Oi SHRUB OR VINE PER PLAN. P L A N T L E(3 E�I :����.:.. u.� O2 EARTH WATERING BASIN (RAKE Z I `4 °L SMOOTH PRIOR TO SEEDING IN G 7 /� y G HYDROSEED AREAS; AT END OF Z SYM5OL PLANT NAME SIZE/SFAO I NCB REMARCS PLANT ESTABLISHMENT PERIOD Z I I � If III— FOR ALL REMAINING BASINS). QJ FINISH GRADE. d 05 ROOTBALL ROOTBALL (SET CROWN +1" ® FICU5 PUMILA - CREEPING FIG YINE 16ALLON _ I II i1=111 I I 5 ABOVE FINISH GRADE). TRAIN TO VINE GABLE A5 CONSTRUCTED q 1 II I=111 I e I— �� I O5 COMPACTED BACKFILL MIX (PER N O —I 6 PLANTING SPECS/NOTES). V P15TICT15 BUCCINATORIA - BLOOD RED TRUMPET VINE I GALLON PER SHEET 0-1 8 DETAIL 'B', 5HEET 0-2. _ _ _ _ = W U5E NURSERYMAN5 TAPE AS REQUIRED TI II — © UNDISTURBED NATIVE SOIL. ~ TO 5ECURE TO GABLE. 2 2 x ROOTBALL DIA.I ;1110 i a W o. a v E FLANT I Nr, DETAIL z - g W a w OLIVENHAIN TOWN COUNCIL "AS-BUILT" APPROVED Z BY. LANDSCAPE ARCHITECTURE DATE: �- PLANNING Luu°P Joe, * BY: 6 RCE: EXP: 637 Arden Drive,Encinitas,CA,92024 DATE (760)944-8463 C�c REVISIONS APPROVE DATE REFERENCES DATE BENCH MARK SCALE ENCINITAS FIRE PROTECTION DISTRICT DESIGNED BY DRAWN BY CHECKED BY APPROVALS` CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT DRAWING NO. w C;4 ;111Venhai- TOaff Y, Council 2.14.01 1 BENCHMARK: OC-0073 PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED IMPROVEMENT PLANS FOR: IL O p' RANCHO SANTA FE ROAD WALL W DESCRIPTION: CHISELED SQUARE IN TOP OF DATE: 11/2000 0 CONCRETE HORIZONTAL 1°'=20° NEIGHBORHOOD ENHANCEMENT SI-OQ23=L cZ LOCATION; 23`WESTERLY L RANCHO SANTA FE R.L A. NO.: 2011 RD.&60'S'LY EL CAMINO DEL NORTE BY: MICHAEL G. ELLIOTT BY: BY: �a VERTICAL N/A DATE (NAME) EXP. 4(30/01 DATE: ��®� PLANTING PLAN SHEET L-1 OF 5 ELEV: 119.467 DATUM: P[-LA . ;t:.:n rRa:>1'onl-ho S€:into Fe WoIi"\I.,.—"i .dwg cue ? comp 11/08/,2000