7806 r
CONDUCTOR SCHEDULE
GENERAL NOTES
I. THE ELECTRICAL EQUIPMENT AND WORK SHALL CONFORM TO THIS PLAN, THE CALIF. STD. PLANS AND 2° C 3° C zVC
21/2 C 2-2 'C
SPECS. DATED JAN., 1980, TRAFFIC SIGNAL LOCAL INTERSECTION CONTROL PROGRAM DATED JULY, 19788 I AWG PHASE 1 Q3
AND THE CONTRACT DOCUMENTS. # 14 1 VEHICLE HEAD 3 3 3
2. PULLBOXES SHALL BE # 5, UNLESS SHOWN OTHERWISE. �w , ® i 2 It 3 1 3 3
3. LOOP DETECTORS SHALL BE 6'x6' EXCEPT FOR BIKE LOOPS WHICH ARE 4' x4'. EIV(�Ite,. // R. C. 24/v55�D�E 4 1
1, 3 3 3 3 3
4. AL-L- TRAFFTC ''STRIPING TO BE DONE BY- COUNTY SAN
_- DIEGO._SA " DIEGO. 1 5
5. MAST ARM°MOUNTED REGULATORY SIGNS SHALL BE FURNISHED BY THE COUNTY OF MWEN64 iVMI11� APPROVED 2 PE D.
HEAD 2 2 2 2 2
6. STANDARDS AIA AND @ SHALL BE LOCATED 3 BACK Of BERM, STANDARD O 2 -6 BACK OF CURB LINE I GP I 1 ATE 4
n 11 2 2 2 2 2 �
„ 04
u �? ( q It
6
AND D -9 BACK OF CURB LINE. 6 2 2 21
7. FLASHING OPERATION SHALL BE RED ON ALL PHASES. 7_
8. INSTALL FOUNDATION, TYPE 332 CABINET AND CONTROLLER. INSTALL TYPE III SERVICE FOR COMBINED 120 V. METERED TRAFFIC \ 2
PED. PUSHBUTTON I I I 1 1
4 n I' I I I I I
SIGNAL -AND' 120 V. METERED .. SAFETY LIGHTING SYSTEM . USE I-P 50 AMP CKT BKR FOR SIGNALS, AND 2-P �' ;• � 6
q n I I
30 AMP CKT. BKR. FOR SAFETY 9 CONTRACTOR TO VERIFY SERVICE LOCATION WITH SAN DIEGO GAS AND ELECTRIC CO. \l\�J F G-vN D J`) !�� �i�/
4 {: \ \ W 11�J�\]\]D � !���� P. P. B . COMMON I I I I 2
�� i �\ —tom SPARES 3 3 3 3 6
10. EXISTING STREET LIGHTS LOCATED ON THE SOUTHEAST SOUTHWEST AND NORTHWEST CORNERS TO BE _ TOTAL 19
22 16 22 3 .
REMOVED'• AND SALVAGED EQUIPMENT DELIVERED TO THE COUNTY OF SAN DIEGO. 114' IP' 14' I
O �\ \ SIGNAL NEUTRAL I I I I 2
I1. INSTALL PEDESTRIAN PUSHBUTTON POLE WITH 04 PUSHBUTTON Al- :LOCATION E I I'co I _. W10 C4
LUMINAIRE 2 2 2 2 2
.
12. CONTRACTOR SHALL FURNISH AND INSTALL REFLECTORIZED STREET NAME SIGNS AS SHOW ON POLE SCHEDULE . / / I Vi1; \ \ 1
LOOP D. L.C. I I
COUNTY OF SAN DIEGO WILL FURNISH SIGN MOUNTING BRACKETS. / 2
11 It I 3
4 3
13. LUMINAIRES SHALL BE HIGH-INTENSITY-DISCHARGE CUTOFF TYPE. EACH LUMINAIRE SHALL USE A TYPE IV PHOTOELECTRIC / - - \ 4
11 11 1
CONTROL. THE OPTICAL ASSEMBLY SHALL CONTAIN AN ACTIVATED CHARCOAL Fit-TER TO PREVENT PARTICULATE AND / g I \ 3 11
GASEOUS CONTAMINATION. THE REFLECTOR SHALL BE SPECIFICALLY DESIGNED TO PRODUCE AN ANSI /IES MEDIUM 7�/ / fj \ 6
11 u
CUTOFF, TYPE III LIGHT DISTRIBUT N. ( / CLOG//F'E
/- �It 8720 BELOEN OR APPROVED. EQUAL _
5E NOTE
C)
1/2 / 4
31— / --- d -v SERVICE \ 1 [/ C 3 DLC
12 4 2 p e 01/2° C, 4DLC �^ CC, IDLC
— #31/2 PS
P
#3 I/2 PB
o I I/2°C I O 0 8v � 4 ti #31/2 Ps I �C , 2 DLC _
- , 2 DLC I 6 _ r2 -
a4t31/2 PB kn�
0 66P (,
OA5L n 12" �l 04 4FI 0 6
N --- - --- &4 T 0 iv _7 04P O6 - _(� L
MI LINE � .006 REAL 7 .
5 `06 1 -
' N �u
o _ - R 34 230' TO -7 �- 6 06
N 5 I r EE NOTE 51 1 _ - h/ N
--�5
oust YELLOW' I°'C, I DLC V PAINTED ISLAND LIMIT LINE
PV 5
3I/2P Z = ' 90, TAp R -- s 10' - S 5 - 5 -
_ 5 330' TO
#31/2 P8 R $
17' 21' 28'
02 AN E LIMIT LINE
—, I DOUBLE YELLOW #31/2 P8 4p _ - -
-
0- 22 Q92 2 ' TAPER 0 5 _JV � 3 3 //-A51. X03 !/�9J X03 8 6 8 6 0
02 �0�_ - '� N 28 21 ' 14' 7' -
�- 2 '_' PV N
-- -r SR NOT
2
. 2 23 -
TO - - - - -
330 —_ LIMI
TO - TO 7 g
UNIT 1 0� `'_ R39M
LINE - LIMIT LINE Ll
%2PB o `fl �, (SEE NOTE 5) 02 .12"
04 _ --
el
8 l� o I 1
31/2 FIB 02 __at
I It I B
C, 'I DLC 2' !� 9
s SC 1"C, I DLC - -
ACF; DETECTOR ASSIGNMENTS ,
PHASE DIAGRAM DET. FIELD TERMINAL.
PHASE SLOT
• ' V'� N Q� � N0. CONNECTIONS
1a ( N Q� LOCATION MAP 1 2 I2U T2 - 5 a 6
u 1 2 3 4 2 2 I2L T2 - 7a8
9 #-31/2 FIB 3 5 J I U T3 - I 8, 2 a°
JI� 4 4 I6U T4 - 9 d 10
Ni1G ��1=1R_Y� 'I I ' 11
- UNUSED �(/ v/ 5 4 f 7U T6 - I a 2 "
N a 6 6 J2U T3 - 5 a 6
5 � 6 7 8 7 6 J2L T3 - 7 8�_8
NO SCALE 8 I Y fU T2 — 1 a 2
a
P O L E S C H E D U L E
• j— 9 ' 4 16L T4.. - 11 a 12" � o
TRAFFIC SIGNALS PEDESTRIAN SIGNALS LIGHTINGa:P REFLECTORIZED 9 - UNUSED UNUSED " 10 2
I3U- T2 9 a10
ST. NAME SIGN
LOC. TYPE MOUNTING INDICATIONS M.A. PHASE MOUNTING PUSHBUTTON LEGEND 6' tI - 6 J3U' T3'
9 8110 �!
LUMINAIRE LENGTH P PS 2 112 U' T8 4 a COM 6
TYPE 10 LOC. MA LETTERING
PRO CT P P B 4 1.12 L T8 3 a COM 6 Z'I
MAS PV 3-12"(R,Y,GA) W 400 W. H.P. SODIUM + Malens f SITE
2 POLE VAPOR CUTOFF TYPE tNtipS MALENA pp8 6 I13U T8 - 7 aCOM 9 `^
MAS 3- 12"' @ Y G) B QUAD LUMINAIRE WITH `'120 V. EVA 2 + 5 J12 U T9 - 4 a COM 6 )
A 26A-4-80 3-12"iR,Y G ) 40 2 d 4 SP- 2-T WITH S H.P. F. REACTOR BAL- 15' 6'
' LAST AND TYPE IV icy ENO DRIVE EVC I + 6 J12 L T9 - 5 d COM 6 9
SV-3 - TB 3�- 8"(R Y G'1 SIGN 4 POLE 6"U.C,,4i2 L•C. eLVO. o
« QUAD P E. UNIT
3-8 (R,Y,04
W 150 W. H.P. SODIUM El Camino Real
2 POLE VAPOR CUTOFF TYPE
MAS 3-12 (R,Y,G ) - QUAD LUMINAIRE WITH 120'V. r
O 19A-4-80 30 2 a4 - SP-2-T WITH N HJP. F. REACTOR BAL- 10 8 'I ° PRIVATE CONTRACT
"
3--8 (R,Y,G 4 SIGN 4 POLE LAST WITH TYPE IV 6 U.C.A4 L.G. Z
SV-2 -TB 5
> PERMITS SHEET
3-COMB (R,Y,GA)`_ QUAD P.E . UNIT. ® �
COUNTY OF SAN DIE�Wo
MAS PV 3-12« (R Y GA) - N 400 W. H.P. SODIUM DEPARTMENT OF PQE3LIC rzk S".
Ei:s ] �.
4 POLE VAPOR CUTOFF TY;OE Ma lens REZONE PERMIT NO.
MAS 3-12"(R,Y,G ) B QUAD LUMINAIRE WITH 120 V. PLANS FOR THE CONSTRUCTION OF TRAFFIOV
26A-4-80 MAS 3.12'1(8 YG ) 4C! 4 a 6 SP-2-T WITH H.P. F. REACTOR BAL- 15 6 SPECIAL USE PERMIT NO. SIGNAL
AND SAFETY LIGHTING SYSTEMS T 1 '
3-12° R Y G SIGN E LAST WITH TYPE IV 6"U.C., 411/,a L.C.
6 POLE z EL CAMINO REAL AND MALENA DRIVE
-SV-3 -T-B r, P.E. UNIT TENTATIVE MAP NO.
Q�1A,D
3- a (R Y G ) COUNTY APPROVED CHANGES BENCH MARK W
150 W. H.P. SODIUM Federhart & Associates CALIFORNIA COORDINATE INDEX 3ZZ —/roB9
MAS 3- 12" (R,Y,G) B 4 PO E, VAPOR CUTOFF TYPE 5252 Balboa Avenue,Sloe 709
Ft4+r pe ;t .y, , --QUAD ° San Diego,CA 92117 No. Deuription Approved by Dote a
® 17A-2-80 20 4 S 6 SP-2-T WITH LUMINAIRE WITH 120 V. 8 DESCRIPTION: �P 82ASS WELL MONUMENT Recommznded^orApa
rov I Approved ° 2C
<7
« (714) 278-3365
_3.12 (R,Y,G-) ; SIGN E H.P. F. REACTOR BAL- Q 7/-1/S SN�ET ADDED .gGGd�+e
Subdivision Engineer �FO.e ),�COri< it T.rs✓ - H
SV-2-TB _ . A r , 6 POLE LAST WITH TYPE IV Drown B C• S• � AS B[Jl(,-T' ��/� y_Ay-g� LOCATION: INTE2SEG�/O/V
eF ENc/N/�AS BLVA. � O
C`. QUAD P.E. UNIT
wr y 4",W &'L. C'AAiJ/MC REAL, Engineer ofi work Checked by C Z
JZF
CONTROLLER SCHED' ta. '9 170 CONTROLLER ASSEMBLY IN MODEL 332 CABINET WIRED FOR DesinedB % �� � _
FULL 8 PHASE CAPABILITY AND INCLUDING THE NECESSARY ACCESSORIES TO 9 Y RECORD C .79 �� SAN D/E�yo Z
=
PROVIDE THE PHASING AS SHOWN ON THESE PLANS Approval date
/2 SZ ✓ob No. z ELEVATION: 220.79 DATUM: S. L. c`� �� CS O
Date: ' JQ. DEVL/N �C•=• 2¢oSS -/�-Bi 2C
FILE N0.