7784 U s� f� a w a 0 a ri U q. ro a N m Q 0 �r 4j 0 h a 0 Q a m 0 u rn co � 0 0 N m a 0 ro a ro 0 0 0 N i H 0 rn h °4 a, x q 3 ro sa ro U i R 0 U N 0 a CITY OF ENCINITAS 1661 LAKE DRIVE ENCINITAS, CALIFORNIA SHE INDEX SHEET CIO. SHEET TITLE T-1 TITLE SHEET E-1 NEW AND EXISTING SITE PLAN E-2 EXISTING ELECTRICAL PLAN WITH 'NEW' WORK NOTES E-3 EXISTING LIGHTING POLES TO BE REMOVED E-4 MUSCO DETAILS E-5 ELECTRICAL DETAILS Nhk A I ti k DATE : 04/30/04 VICINITY MAP DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF ENCINITAS IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. (NAME, ADDRESS & TELEPHONE NO. OF ENGINEER OF WORK) BY: THOMAS E. HARTMAN DATE: 04/30/04 LICENSE NO. : 7531 EXP. DATE: 09/30106 4+ REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 E—MAIL : ee0reedcorp.net GENERAL NOTES A. SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID. FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG. B. BALLFIELD LIGHTING GENERAL NOTES- EXISTING SITE C. SECURE EXISTING PLANS FROM CITY (ELECTRICAL, AND THE UTILITIES, IRRIGATION, ETC,) AVOID EXISTING UNDERGROUND ELECTRICAL AND SPRINKLER SYSTEMS WHERE POSSIBLE. REPAIR ALL EXISTING SYSTEMS DAMAGED BY CONSTRUCTION TO CITY'S REQUIREMENT. D. CONTRACTOR SHALL CAREFULLY REMOVE, STORE, AND REPLACE EXISTING SOD AFTER INSTALLATION IS COMPLETE. ANY EXISTING IRRIGATION PIPING OR OTHER UTILITIES WHICH ARE DAMAGED OR REQUIRE RELOCATION DURING CONSTRUCTION SHALL BE REPLACED TO THE SATISFACTION OF THE CITY. E. TRENCHING NOTES: 1) TRENCH AROUND PLAYING FIELDS AND NOT ACROSS INTO OUTFIELD PLAYING AREAS EXCEPT AS INDICATED OR UNAVOIDABLE. 2) CONTRACTOR SHALL VERIFY WITH CITY EXACT TYPE AND WEIGHT OF CONCRETE TRUCKS TO BE USED ON ALL TURF AREAS. DO NOT USE TRUCKS WITH WEIGHT NOT APPROVED BY THE CITY. 3) RUTS WHICH ARE MADE WITH CONCRETE TRUCKS SHALL BE REPAIRED INCLUDING CORRECTION OF COMP ACTION AND TURF REPLACEMENT AS REQUIRED BY CITY. 4) ALL BACKFIELD SHALL BE COMPACTED IN 6" LIFTS TO MATCH SURROUNDING SOIL OR 90%, WHICHEVER IS LESS. F. CONTRACTOR TO VISIT EXISTING SITE AND VERIFY ALL EXISTING CONDITIONS. G. CONTRACTOR TO OBTAIN ALL PERMITS AND INSPECTIONS AS REQUIRED AT NO ADDITIONAL COST TO CITY. H. VERIFY ALL POLE AND OUTLET LOCATIONS WITH THE CITY BEFORE COMMENCING WORK. POLE AND OUTLET LOCATIONS AND CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY AND MAY NEED TO BE CHANGED TO SUIT FIELD CONDITIONS. (VERIFY WITH CITY.) SEE NOTE "B" ABOVE. 1. ALL MATERIAL SHALL BE DELIVERED TO THE SITE NEW, IN THEIR ORIGINAL UNBROKEN PACKAGES BEARING APPROVAL BY U.L., NEMA, NBFU, OR ANY OTHER APPROPRIATE AGENCY. J. PROVIDE TYPE WRITTEN DIRECTORY (LAMINATED AND SEALED) INSIDE EACH PANEL DOOR. K. ALL WORK SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (1999 EDITION), AND ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES APPLYING TO THE PROPOSED CONSTRUCTION. IN THE EVENT OF A CONFLICT BETWEEN THE ABOVE AND THESE PLANS AND SPECIFICATIONS, THE RESTRICTIVE SHALL GOVERN. L. CONTRACTOR SHALL MAINTAIN ONE SET OF "AS-BUILT" PLANS MARKED IN RED SHOWING EVERY CHANGE, ADDITION, DELETION OR MODIFICATION INCLUDING EXACT ROUTING OF CONDUITS. THIS "AS-BUILT" SET SHALL BE RETURNED TO THE CITY BEFORE FINAL ACCEPTANCE OF WORK. M. CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM MEETING THE LETTER AND THE INTENT OF THESE PLANS AND SPECIFICATIONS. N. POLES STORED ON SITE SHALL BE HANDLED (INCLUDING DELIVERY AND SETTING) WITH APPROVED STRAPS TO AVOID DAMAGE TO GALVANIZING. ACCEPT POLES FROM MANUFACTURER'S DELIVERY IN THE PRESENCE OF CITY VERIFYING ANY DAMAGE. POLES STORED SHALL NOT SET ON GRADE. SET POLES ON WOOD BASES AND TURNED 180 DEGREES EVERY 48 HOURS MINIMUM. TOUCH UP PAINTING (GALVANIZING) SHALL BE PER POLE MANUFACTURER'S REQUIREMENTS. 0. SEE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 04/30/04 REEDCORP ENGINEERING 6 CONSULTING ELECTRICAL ENGINEERS °' 2061 Business Center Drive, Suite 110 Irvine, CA 92612 Lo (949) 752-1278 FAX: (949) 752-1287 1 E—MAIL : ee0reedcorp.net o W W U w ..J M Um Irk Lo 8 a. CS o � o W a � W DO N Z Z V V J W W LL 0 00 w w a 0. 0 SHEET NO. T-1 SHEET 1 OF 6 i k i 4 t 1 1 t j z s A t I' I i1j I I i t 1 I I EX. UTILITY POLE NEW AND PLAN NOTES: (NEW WORK) �1 EXISTING PULL BOX TO REMAIN. PICK UP AND EXTEND EXISTING CIRCUITS TO NEW POLE PER NOTES 8, 9, 10 BELOW. 2 EXISTING POLE. REMOVE POLE AND CONCRETE FOOTING. NEW POLE FOOTING TO BE PLACED IN SAME LOCATION. REPLACE CONCRETE WALKWAY. ❑3 NEW POLE WITH RELOCATED BACK LIGHT. F4] NEW POLE. (NO BACK LIGHT). 4A NEW POLE WITH NEW BACK LIGHT MATCHING EXISTING. CONNECT TO EXISTING SECURITY LIGHTING SYSTEM. EXISTING BACK LIGHT (FIXTURE 'B'). REMOVE AND INSTALL ON NEW ADJACENT POLE ❑6 EXISTING CELL TOWER POLE. REMOVE EXISTING LIGHT FIXTURES AND MOUNTING BRACKETS. INSTALL NEW MUSCO LIGHT FIXTURES AND MOUNTING BRACKET PER DETAIL. ❑7 NEW FIXTURES AND BRACKET ON CELL TOWER POLE PER NOTE NO. 6 7A NEW FIXTURES ON PROPOSED NEW CELL TOWER POLE NOTE NO. 6 aNEW 1 1/2" C. 6 #10 (SPORTS LIGHTS= 2 CIRCUITS + 2 #10 (BACK LIGHT) + 1 #10G FROM NEW POLE INTO EXISTING PULL BOX (OR NEW PULL BOX) CONNECT TO RESPECTIVE EXISTING CIRCUITS IN PULL BOX) ❑9 NEW 1 1/2" C. 3 # 10 + 1 #10 G FROM PULL BOX INTO POLE AND CONNECT EXISTING CIRCUIT. ElNEW 1 1/2° C. 3 #10 (SPORTS LIGHTING) + 2 #10 (BACK LIGHT) + 1 #10G FROM PULL BOX INTO POLE AND CONNECT EXISTING CIRCUITS. 11 PROVIDE NEW PULL BOX IN GRADE INTERCEPT EXISTING CONDUIT AND WIRE. 12 1 1/2" C.O. TO POLE 'A6' FROM MUSCO 'CONTROL-LINKS' CABINET FOR COMMUNICATION DISH. SAW CUT WALKWAY TO BUILDING (SURFACE) TO MUSCO CABINET, 13 PROVIDE TWO MUSCO CABINETS IN STORAGE ROOM AS DIRECTED BY CITY. SEE E-5 14 NEW TYPE 'A' LIGHT STANDARD PER E-5 15 PICK-UP EXISTING BACK LIGHT CIRCUIT AND CONNECT TO NEW TYPE 'A' LIGHT STANDARD. CONTRACTOR TO TRACE OUT ALL EXISTING CIRCUITS TO ALL BALLFIELD POLES FOR RECONNECTION TO NEW POLES ELECTRICAL SYMBOLS ❑1 = NEW WORK PLAN NOTES 20 = EXISTING CONDUIT/WIRE CIRCUIT PER 'FEEDER SCHEDULE', SHT. 2 • • = NEW LIGHT POLE • OA = EXISTING LIGHT POLE = EXISTING BACK LIGHT RELOCATED FROM EXISTING POLE TO BE REMOVED ® = NEW PULL BOX © = EXISTING PULL BOX ALL ELECTRICAL ON THIS PLAN IS EXISTING AND IS FOR NEW DEMOLITION WORK AND NEW WORK, NEW WORK NOTED AS 'NEW'. IT 0 l 15' 30' 60' SCALE: 1 " = 30' SITE ADDRESS: 1661 LAKE DRIVE ENCINITAS, CA 04/30/04 0 REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 E—MAIL : ee®reedcorp.net o 5 a UJI U) 0 W z Q W Z 9 r J W J F V W's w CL SHEET NO. E-1 SHEET 2 OF 6 Ln o � a O O �1 U I.L W CL Ir Z Z V J W LL on !Y Q av C(NiBINAT1O4 1 I S ° ICE AND i EXISTING- - t I g SECTION , .. ... CT. iN ,:...: . .,,..:.__ ..:_.,.....:...�..._........._,�... NEW ...r,, cr m sa d . .,.. r.,..: e°e "s ... #., .. a TABLE f$. SYMBOLS . .,, ,.., tTRIi4TEC N - % Cs3i Fdt._ ---`4------ � �. x �a � YS y �` � ... ,.� ._ �'..�i a' �__�>. �' �' . � � 1�. €# i3 �.lv'. _ WATTAGE . s g.,.».....,.......,..»..m....«.— ----------- 1 MTG. HT. 2 SYMBOL 3 DESCRIPTION POLE I POLE � NO. CF I MTTAGE I wi=. DESIMPTION 1 FEEDER FEEDER SIZE - KW t 1I 3. » ! 1 S. » AG i a » k3R w 1JROp » 1 +4$ » 3 DES .ti 1Pli, 2€ a2, 3P 3, 4P-S4 - � 5.0 ; ' Al 543 # 3 ? � __° 1T�i N.F. D a i' F 3010, 1#10G -M I.4G3 » 3 €4' 2 aa� 1Y £3Ax 0) W 0 +Z 0 W z Z 4 J d 4 H V W J W 0 z X W I EXISTING tSkl _ (} 3 AS i1 fo� I TO m ,s° FLUORESCENT STRIP U41T WITH AS EI TC ».... -TOR 1,/34 Rs PRUMVIAL AR-101-48PIS .«me 1 MU YMNIED CAST .I E1[aM HOUSMo TAT 122311. 35 T4 ? BIEMR # - _LPS=35-120 » s B , T, 1i1 UNIT. P a C vg P a i s I1 . s 12Ota PANEL. SPz i l p _ ......TABL�m�_ I_ SOD1124 �,,....N� e s y su Items st tuba indicate startdara3 cif quality. Refer tai specifications for sc�at3tt8Cz�ns. NEW WORK i Ins Switch -° 40/2 24 Br, dial, .7 days, with spring Sao carryover and a tro ®� riiais Paragon 423-flOs . NEW MUSCO �s NEW BALLFIELD LIGHTING 156.7 A 'CONTROL-LINKS' i,) !ODA -a 3P Electrical�held Lighting contactor, with auxiliary contact and E IST9NG GALLF6ELD LIGHTING t i . 5I K�fA CABINET. SEE E5 120 coil1 Square ss 8903, t -2. t } 30 - 3P Electrically held Li2hti? g contactor, with a 31 is contact, tsre SECURITY L 1 G N T 3 N 5.3 4 switch, photocell-c ontrol. l OV a 1, Square D Class 903,� G-2. PARKING LIGHTING 4,0 1'= um c 4 } Parelboard 480V. 3 Use 18 circuit a 100A Bus, in lmags Only, with bolt-on branch breakers as -h scat 1. Square D I-LINE. O E S TqOO M SUILI)ING AND Lion � 6 <r5) Same as 4 except 12 circuits. _.. iS iL1.1? CNCta3d } 5 KvA 480--120/24OV. 1 phase transformer , by Sorgel.. TAHP PWID 7') Panelboaral 120/240 . i phase 3W with 30A. 2P min cixcaxit ksrea rand 198:5 A NEW WORK � .F" .� � �..��. s _ FEEDERS TO N.E. BALLFIELD LIGHTING Bolt-on branch breakers as :indicated, square D, type NQW. TO BE REMOVED � — LO 8 FEEDERS TO N,W. BALLFIELD LIGHTING ❑ 8; On-Of push button station, Square D Class 9001, 198.5 A X tPS 248.1 KVA AND REPLACED w�, � .T � �O' a FEEDERS TO S.E. BALLFIELD LIGHTItdr 5 - WITH NEW O o (A) 20A �- IP 120/277 switch, 9 - By-pass switch fans° photocell. ® 298 AMPS AT 4801277V, (BALANCED LOAD) FEEDERS TO S. S. BALLFIELD LIGHTI dt1 IQ7 20A - 125"x7 . 5-20R, weatherproof receptacle, OFT, type. Hubbell � GF 53 21 d z FEEDER TO PARKING 0,10 SECURITY LIGHTING i�) {1) 4' single 35W fluorescent lamp fiXtUre> TYPe "D" fixture. 99 NEW 1500 WATT, M.H. F4 TLIRES= 99 X 1650 W X 1,25 (LCpC)= 204.2 KW= J 246 AMPS 'BASED ON 480V, 3 BALANCED LOAD) H NEW WORK NOTES ALL ELECTRICAL ON THIS PLAN �— Z Z 12,E ,4#e", h" WIM . 1❑ DISCONNECT AND REMOVE EXISTING CONTACTOR. � PULL EX. REST ROOM EXTERIOR LIGHTING CIRCUIT AND WIRE IS EXISTING AND IS FOR NEW V V J THRU NEW MUSCO "CONTROL-LINKS". DISCONNECT EX. ON-OFF CONTROL. DEMOLITION WORK AND NEW WORK. W W — 2 DISCONNECT EXISTING CONTROL TO CONTACTOR. NEW WORK NOTED AS 'NEW'. LL PICK-UP AND EXTEND TO NEW MUSCO 'CONTROL-LINKS' CABINET. F TWO NEW NEW CONTROL WIRE CIRCUIT SOCCER FIELDS (2) 0 0 QQ SEPARATELY FROM 4 BALLFIELDS PER E-5. ❑3 PICK-UP AND EXTEND EXISTING CIRCUITS TO MUSCO CONTROL a 1 1/2" C.O. TO POLE 'A6' FOR MUSCO COMMUNICATION DISH. CABINET AND BACK TO RESPECTIVE CIRCUIT BREAKER. 04/30/04 SHEET NO. REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS ° 2061 Business Center Drive, Suite 110 Irvine, CA 92612 LO (949) 752-1278 FAX: (949) 752-1287 E-MAIL : ee®reedcorp.net o fir.. - T i ,k t m i c� *,v 0 0 C5T 70-6 L/r4,1-1T1Nq_�ff0LF- -xv 74 Li TB I R 0 11 FT�TUICF- Ov 5A.11-L.Firmut? NOTE: EXISTING POLE 'C5' WAS REMOVED IN 2003 AND REPLACED WITH NEW CELL TOWER POLE TO REMAdN J �w zz LU z- LU Ui 0 on 61z, 5,5;'n4�� A-7—, A% A 4 �70 "PAR y - A,- A A 4Z NOTE: EXISTING POLE 'C5' WAS REMOVED IN 2003 AND REPLACED WITH NEW CELL TOWER POLE TO REMAdN J 04/30/04 SHEET NO. E=3 SHEET 4 OF 6 0 0 zz LU LU Ui 0 on 04/30/04 SHEET NO. E=3 SHEET 4 OF 6 U H N N v c G w F-I 0 U m m U Pa a 14 L14 N r N Q 0 m 0 h ra c1n m 0 0 �1 ro P 01 0 o, 0 0 Ln N L a 0 m a 10 m ro ca ro U U w I w i 0 i h 0 a a x Q S ro 1-! 1 m U i a 0 0 U 'd N N EXISTING BACK LIGHT FIXTURE 'B' RE-INSTAL ON NEW MOUNTING BRACKET 90 WATT, LPS, 277V VERIFY TENON SLIP FIT WITH MOUNTING ARM PROVIDED WITH POLE) k1CUNTING BRACKET MOUNT +25' ON EXISTING POLE. SEE SITE PLAN � o C/ 2 3/8" HUB ,��\ 2 3/8" DIA. GALV. REDUCER WIREWAY 6�6 BY CONTRACTOR (COORDINATE COVER W/FIXTURE MFG FOR EXACT SIZE) PLATE MOUNTING BRACKET BY MUSCO t6" MOUNTING ARM AT +22 FT ~-I_ BY MUSCO 11" -- GROUNDIG KIT N BY MUSCO `a. MOUNTING BACK PLATE BY MUSCO LIGHT POLE HANDHOLE BACK LIGHT FIXTURE ' B' DETATS n RG-11 COAXLE CABLE FURNISHED AND INSTALLED BY MUSCO CONTRACTOR TO PROVIDE 1Y2" RIGID GALVANIZED CONDUIT. PIPE STRAP TO POLE. STUB UP +18' TO MUSCO CONTROL LINKS CABINET NOTES: z 1. CONTRACTOR TO PROVIDE AND INSTALL MUSCO COMMUNICATION BRACKET. ' BRACKET TO FACE AS DIRECTED BY MUSCO. M DLDNTING STRAP KIT SG1318-?(2 REQ'D) CO COMMUNK 4-EX. CONTACTORS Wire support WWRhleQuick Connectors Ballast cabinet em"� ing to fixtures ssruiapp hook 2. REFER TO INSTRUCTION SHEET ;- BSCR2 FOR INSTALLATION OF ^" STRAP ASSEMBLY. MAX. AMP RATING LUG SIZE WIRE SIZE GALVANIZED U-BOLT 1 OF FIXTURES BRACKET BY W (n I 1 W W = 1- ff 0 W Z N CONTACTOR. VERIFY SIZE 1-9 35 Spa #3 480 EXISTING GAVANIZED 10-18 SPORTS LIGHTING 1 14-1 0 POLE M DLDNTING STRAP KIT SG1318-?(2 REQ'D) CO COMMUNK 4-EX. CONTACTORS Wire support WWRhleQuick Connectors Ballast cabinet em"� ing to fixtures ssruiapp hook Handhole Cover Grade Line —Conduit Adaptor Plate With Access Hole, Below Grade (2 Sides) Not To Scale CABINET - CIRCUIT BREAKER SCHEDULE BALLAST VOLTAGE SYSTEM PHASE METAL HALIDE MAX. AMP RATING LUG SIZE WIRE SIZE 1�OF FIXTURES 1 OF FIXTURES 480 W (n I 1 W W = 1- ff 0 W Z N 1-6 1-9 35 PHASE C = 2 FIX. #3 480 7-12 10-18 80 1 14-1 0 3 480 13-20 19-20 109 (1 14-1 0 3 480 21-35 31-52 175 1 6-350 MCM #2/0 277 i-3 1-5 35 1 14-1 0 3 277 4-7 6-10 60 9 14-1 0 3 277 8-12 11-18 109 (1 14-1 0 3 277 93-20 19-39 175 1 6-350 MCM #2/0 240 1-3 1-4 35 0 14-1 0 3 240 4-8 5-9 60 1 14-1 O 3 240 7-90 10-15 100 1 14-1 0 #3 240 11-18 16-29 175 (1) #1-500 MCM OR (2) 1-250 MCM #3 208 1-2 1-4 35 1 14-1 0 3 20g 3-5 5-8 60 1 14-1 0 3 208 6-8 9-13 100 1 14 0 3 208 9-15 14-23 175 01 (1) #1-500 MCM OR (2 1-250 MCM #3 Handhole Cover Grade Line —Conduit Adaptor Plate With Access Hole, Below Grade (2 Sides) Not To Scale NOTES: POLE WIRING SYSTEM 100A PANEL — WITH 6-20A/3P C.B. A/B B/C A/C A/B B/C TO BE REMOVED. A/C A/B THREE FIXTURES FOUR FIXTURES PHASE A = 2 FIX. PHASE A = 3 FIX. PHASE B = 2 FIX. PHASE B = 3 FIX, PHASE C = 2 FIX. PHASE C = 2 FIX. TYPICAL WIRING OF FIXTURES WITH 30 DISTRIBUTION ,TION BRACKET n N.T.S. SECURITY/PARKING 2 \ LIGHTING TIME CLOCK 2 I- 4-ON/OFF PUSH BUTTONS VL I r--I r� r I II II II I L_J I-_j L J L WIRING SCHEMATIC (Ballast Cabinet) A/B B/C A/C A/B B/C FIVE FIXTURES PHASE A = 3 FIX. PHASE B = 4 FIX. PHASE C = 3 FIX. FIE A/B B/C A/C 1000 SIX FIXTURES PHASE A = 4 FIX. PHASE B = 4 FIX. PHASE C = 4 FIX. LE LIGHT MUCM SM POLE BY YUSCO LIGHTING, INC. (SEE POLE DIEN'1MCATION) Lim SIRUCM PBECASI P18S BASS BY mm u(8f19HG HNC. (SEE POLE P XT mSN1B?ICAISOB) I Y POLE FOUNDATION SCHEDULE NOTES: 1 ❑ EX. LABEL "RESTROOM 100A PANEL — WITH 6-20A/3P C.B. FED OFF MAIN BUS ❑2 TO BE REMOVED. —� [3 120/24OV, 10, 3W PANEL. -� M 70A/3P C.B. 'NC' 0 70A/3P C.B. 'NW' 6 6OA/3P C.B. 'NE' A/B B/C A/C 1000 SIX FIXTURES PHASE A = 4 FIX. PHASE B = 4 FIX. PHASE C = 4 FIX. LE LIGHT MUCM SM POLE BY YUSCO LIGHTING, INC. (SEE POLE DIEN'1MCATION) Lim SIRUCM PBECASI P18S BASS BY mm u(8f19HG HNC. (SEE POLE P XT mSN1B?ICAISOB) I Y POLE FOUNDATION SCHEDULE TYPE FORCES (MAXIMUM) CAISSON 100A PANEL — WITH 6-20A/3P C.B. -7 60A/3P C.B. 'NW' DIAMETER INCH EMIM FEET LS50-A ❑ ® ® 0.604 0.625 30" 8'-0" LS60-A 38.68 0.951 1.15 30" 5OA/3P C.B. PARKING/SEC. L570-A 70.03 1.380 NE SE 30" 12'-0" LS80-A -1 91.56 1.671 2.191 30" 14'-0" � 3OA/3P C.B. FUTURE. C THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION e400A MAIN A 100A PANEL 10 30A/3P C.B. (RESTROOM PUMP) 7B 11.680 D61G13— N PARAMETERS 3] WITH 3-20A/3P C.B. 23.75" (7.5 KVA XFMR) 1 C� � NW F11] 15A/3P C.B. 5 KVA XMR ® go 0 0 %" kO SW z (CONCESSION) UGPS D m W 12 EX. 5 KVA TRANSFORMER. 0 a 0 �a 13 TWO NEW W.P. 6" X 6" GUTTERS TO MUSCO CABINETS IN STORAGE 8]ffEj 0 12 ROOM. ONE TO HAVE ALL BALLFIELDS TO CABINETS LIGHTING CIRCUITS 10 [� Cj 11 AND ONE FOR ALL RETURNING WIRES, INTERCEPT EX. CIRCUITS IN SWITCHBOARD AND EXTEND WITH MINIMUM NO. 8 WIRES (54 NO. 8 WIRES IN EACH GUTTER. FIELD VERIFY EXACT QUANTITY) EXISTING MAIN SWITCHBOARD (D 400A 480/240V 30 4W N.T.S. A/B B/C A/C 1000 SIX FIXTURES PHASE A = 4 FIX. PHASE B = 4 FIX. PHASE C = 4 FIX. LE LIGHT MUCM SM POLE BY YUSCO LIGHTING, INC. (SEE POLE DIEN'1MCATION) Lim SIRUCM PBECASI P18S BASS BY mm u(8f19HG HNC. (SEE POLE P XT mSN1B?ICAISOB) I Y POLE FOUNDATION SCHEDULE TYPE FORCES (MAXIMUM) CAISSON YOL6N1' (Y) 1�-FT SHFAR (V) EB?3 VERTICAL (P) SIPS DIAMETER INCH EMIM FEET LS50-A 20.31 0.604 0.625 30" 8'-0" LS60-A 38.68 0.951 1.15 30" 10'-0" L570-A 70.03 1.380 1.633 30" 12'-0" LS80-A -1 91.56 1.671 2.191 30" 14'-0" GENERAL NOTES LOCATLON IIABE o PRECAST BASBTYPE F18 m CONFIGURATION (FC{fURB3 PER CROSSARM) FIXTURE EPA Al THRU A8 LS50-A 1B 3 OD ., ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO THE 2B ^ 0 PQ PQ