Loading...
1654 BATE( I.�F4S:'LAGOON ENCINITAS SANITARY DISTRICT CONSTRUCTION PLANS FOR GRANDVIEW; T4;:0.' AVOCADO c� L E U C A D F A m u OONLIGHT ACH P MP STATION V NTILATION AND W T W L IMPROV M NTS � r SAN DIEGO C 0 U N T Y PROJECT SITE BLVD. ... NITAS GENERAL NOTES CONTRACTORS NOTES 1 . THE CONTRACTOR SHALL SUBMIT TO THE DISTRICT A DETAILED CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE 5 CONSTRUCTION SCHEDULE WITHIN FIVE DAYS AFTER APPROVAL OF THE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, LOCATION MAP "AGREEMENT" BY THE DISTRICT. THE CONTRACTOR WILL NOT BE CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME NOT TO SCALE ALLOWED TO BEGIN CONSTRUCTION UNITL AFTER APPROVAL BY THE SOLE AND COMPLETE RESPONSIBILITY FOR JOBSITE CONDITIONS DISTRICT OF AN ACCEPTABLE SCHEDULE. DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, THE CONTRACTOR SHALL NOTIFY THE DISTRICT'S .INSPECTION INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS DEPARTMENT 48 HOURS IN ADVANCE OF BEGINNING WORK TO REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND ARRANGE FOR INSPECTION OF PROJECTS. NOT . BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, 3. THE CONTRACTOR SHALL AND HEREBY DOES GUARANTEE ALL INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE- OF ANY AND ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH ACCEPTANCE OF THE WORK BY THE OWNER AND SHALL REPAIR THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING OR REPLACE ANY OR ALL SUCH WORK, TOGETHER WITH ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN OTHER WORK WHICH MAY BE DISPLACED IN SO DOING, THAT PROFESSIONAL. MAY PROVE DEFECTIVE IN WORKMANSHIP AND/OR MATERIALS WITHIN THE ONE YEAR PERIOD FROM DATE OF ACCEPTANCE WITHOUT EXPENSE WHATSOEVER TO THE OWNER, EXCEPTING ENGINEER'S STATEMENT OF RESPONSIBILITY ABBREVIATIONS ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT. A.E.D.' AIR EXHAUST DUCT 4. NEITHER THE OWNER NOR THE ENGINEER OF WORK WILL ENFORCE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS A.E.G. AIR EXHAUST GRILL SAFETY MEASURES OR REGULATIONS. THE CONTRACTOR SHALL DESIGN, PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER A.C. ASPHALT CONCRETE CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES, INCLUDING DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE ALUM ALUMINUM SHORING, AND SHALL BE SOLELY RESPONSIBLE TO CONFORM WITH BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN 1S CL CENTERLINE ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, CONSISTENT WITH CURRENT STANDARDS. CONC. CONCRETE LAWS AND REGULATIONS. INCLUDING TRAFFIC CONTROL PLANS, DETOURS EL. ELEVATION AND SIGNAGE. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND THE EXIST. EXISTING SPECIFICATIONS BY THE CITY OF ENCINITAS IS CONFINED TO A GALV GALVANIZED 5. ALL OPERATION CONDUCTED ON THE PREMISES, INCLUDING RUNNING REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINEER OF H.P. HORSEPOWER OF TRUCKS AND EQUIPMENT SHALL BE LIMITED TO A PERIOD BETWEEN WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. MFG. MANUFACTURER 7:30 A.M. AND 5:30 P.M., MONDAY THROUGH FRIDAY. NO WORK NTS NOT TO SCALE SHALL BE DONE ON SATURDAYS, SUNDAYS OR HOLIDAYS. / OAE OR APPROVED EQUAL Fi SCH SCHEDULE 6, CONTRACTOR SHALL MAINTAIN THE WORK AREAS, IN A NEAT, SAFE, ��" SPECS SPECIFICATIONS � � / SQ. SQUARE � CLEAN, AND SANITARY CONDITION AT ALL TIMES AND TO THE �'1 �� ry �—�— g� - ,. SATISFACTION OF THE DISTRICT AND REGULATORY AGENCY. STREETS No. 49036 a'M a TYPICAL S RAY H. FAKHOURY R.C.E. 49036 DATE r W W WATER HALL BE KEPT CLEAN OF DEBRIS, DUST, AND OTHER NUISANCE W/ WITH AT ALL TIMES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY EXPIRATION DATE: /2�/ y� ICK o CLEAN—UP OF ADJACENT STREETS AFFECTED BY HIS CONSTRUCTION. � ( �� M AU- 0 a = C�O i 7. CONTRACTOR TO OBTAIN A PERMIT FROM THE CITY OF ENCINITAS J 125 ENGINEERING SERVICES DEPARTMENT PRIOR TO START OF CONSTRUCTION. W NO FEE WILL BE CHARGED FOR THIS PERMIT. CID SHEET INDEX SHEET NO. DESCRIPTION LiJ 1 TITLE SHEET, LOCATION MAP, NOTES & ABBREVIATIONS :2; 2 PLANS, SECTIONS AND DETAILS Q 3 SITE PLAN AND ELECTRICAL PLAN z .. Q ry • ° z Ld wVw zwz 0 REVISIONS APPROVED DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT N. U. TAILOR �O R R.CHECKED Y' APP z < _ H. F K OU Y APPROVALS ENCINITAS SANITARY DISTRICT DWG. NO. w < In PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED APPR LANS FOR THE IMPROVEMENT OF: HORIZONTAL �— 7— BY: - a '1�' DATE. 9 B'• MOONLIGHT BEACH PUMP STATION E S 18 6 VERTICAL �� R.C.E. NO. 903 LLOYD J. �HOLT ALAN D. ARCHIBALD �►L �� R.C.E. 18189 R.C.E. z1 ass VENTILATION AND WET WELL IMPROVEMENTS ENGINEER EXP. /ZG/9G DATE: /® — o DATE: —� WORK PROJECT NO.: SHEET 1 OF 3 A F E 5 k x • ......:,,,,.., ..,....,. ....,,..,...........:.................n.... ..,,,..,. :....,,.,...............,,.... ..... ....., ... .... ...... fn. .. ..E. y s s . ....�,,.. w.H:.k.. .::.< ::::...:::::n:w.:,:.: ...,., .:::,..:-.:.....,:.:::: :,::. :..:..: : ..: .:.�:� }:.w..:..::,:....:,,..,.:u.,:::_.,:::. : ...,...::�.::.::.n..... ,...�.u: _-..-....... EL. 18.95 i/4" � EXPANSION CONCRETE• �• s:...s�<.�:�<,;�• �s;.� r..,, k .� ��:. � � EXIST. BOLT W/ NUT AND + s CEILING LOCKWASHER (TYP) •} E � s i DUCT SUPPORT a }:.,...,,.....,,,,....,.....' ` x� x r 3'-4" 1 WIDE GAGE .....n.....,....n. .W,.r ,;:.:,, „ I r s •t I :,:. 16" 1 " HANGAR STRAP X 6 A E.G. I I:..,.,,,,,,,w,,: ......,,...:.,,...,..... `�' '4• � E 2 " D WITH R�:}., "I:s� lx; ;' F'' ��> ,�;� :• E I 20"X 0 BEN `E TURNING VANES (TYP 1 20" SQ. DUCT :. ``t..w:,.:;' k^�'t.., ,�`��+ ;`� �.r' `•,,�;�• ,::,.:� : � 20"X20" }�•:.„,w.�,.:::�:k.::::.:.::.::�:rl I , AE.D. s 2 10 � -� SCREWS FAN `�`--•- � WELDED STEEL BRACKET k •` s1 k 16”X 16 f ,€w.., � ,. t:^is<c.•,' ':3 3 Cr"• �:r,,;,3:�'i E.G. EXIST. —.-� $ DUCT SUPP6RT DETAIL 1 ONC. BLOCK �."Ylr?.. REV sy ,:,y .. E;,.,•:. 1r r w, i W. s <; 4 ,•. :. ?WALL SECTION 1 � � NO SCALE .;`k,z [�};•• LEVEL SENSOR PANEL WET WELL } —L ,•3 11 ,. �' 2 LEVEL CONTROL a ��••• '°� <: � EL, 4.93 1 AND CONDUIT TRANSDUCER z w rrw rrr .r ; :'•<:::w.: ^:;„; I s°��, :,k,,..�.,,s;.l, PER SHEET 3 3 ..w 51 i,.e:.%n.e DUCT SUPPORT WELDED € STEEL BRACKET .., .......................... .....,......... ... .,....,..,...n.....,.... ....n .,. ... f 2 k `L•r•.�., �., S i j.,. ...,,..,.. ...... .. , ........ ...... ........................ .:..... ....... � REMOVE EXIST. FLOOR A.E,G, s g t. FAN AND INSERT 12"� k rte• .., # t X. , , r..., .,.•.„ ,-.,-,. .-,.-.,...., ,,..,, ,.,.. .,,.. .,.........,. r.,.,...,,,,r..,,,..w..r. ..,r...,•�r.,v. r..,,,,-rrrrr.,......-. .,6...r r.,,..„,..r..r�.,,,n..:.............rr,:, ..rrr..,...,.....,,,,,. rr r..,,..wr.,,....,,......-r:,.r.,.,,.w.w..,:.. # B T - - ---------- EL. 3.09 r 20"X20” A.E.D. s „# ? E3 _-- k R N F N TO DISTRICT C --- k --- a € �- 12"X1 A.E. ACCESS DOOR —•§ E ' k -SAND STAIRWAY y 12"� (TYP OF 2) TWO 3/4"0X4" EXPAN$10N t t —�"` -- 3 s '€ TO WET WELL I' € a r r # A.E.D. WELDED STEEL BRACKET ' < ,.,.E s' I `, < °.?:. w ° F ,f;; 1 A. D. A.E.D. f s GRINNEL BRACKET N0.` 2 ! BOLTS W/ NUT AND € € € <� :>Y .:.:: :...:.:,. :....w:.:.::::. .: f LOCKWASHER TYP _ € f € w.. .1 ....x< _..,....r.,. r.:..,,,-.,,-. ._ ;: r �.' FIG. 195 (TYP) OR EQUAL ( ) 'd EXIST. BUBBLER E::^,.:...........-.`...... "' .................... �: �'�.:� 9 6” 1 i DUCT SUPPORT COMPRESSOR m .•,°r•yr t J k r I —RELOCATE EXISTING 1/2” STEEL PIPE TO ACCOMODATE E v } ....•..:.w:::... ,.y:..: .:.:.. }:.::�..::......:w:: ... :.:.v.,.:.::::.:..:......•:.wwn:..::w.u....:.:::.....:u:u:..:.::..::n...::....:.:.k:..,.u.h Q.....n:.:.,.,::..u::::..:.. ...u..•:...:..::.n,,:..,:.w.xv::..,.:.....::.......:' ... .... .. 5 , •.u....0 .....nv....u:uuu•.uuu.:::,.:,:•::.v.:.•.v:>.:w:.:..w:::v:...uuw>....::.:..::.v;.•::.vwu..v.::v.:..:,::.,•:::::::: � , ,. M.. !. ' 8' " fl E � x � � +�{ a € `. :.;,.:.}•:<::�ta,E.�< .., , i``�;.� s NEW DUCT. CONTRACTOR TQ FURNISH & INSTALL NEW PIPING, w.w...,,. ., „ww ....w ....: ......... nx.x.:.r:..,......,..€.:..,.r.,,w,,,..:::.,...., & FITTINGS AS REQUIRED. . . ,.,... .. .. .......... .........._. .,........ .......... ... ... ....,.::.,,.:.,.:::::::,.„......:.,...:._.,,.�..r.:..:..,,.:.,..,.:.,,.:.,,.:.,...,..w.:..,..,:: ..::::::.,v:::.,..::..:.:�.:.....::::.::.,,,..,..,..,.:..w.w:rrrr:.,,,,,.r...rr...:.rrr.:w.....,,,.::.:..,.:.,..,,,...:,.:.:,,,..r.,...:.,..,.:::::.,..,.::::.:.::::::...r..n,,,,.:.,.:n,,. ^ ' AIR EXHAUST ALUM. WALL FAN s E ( ) 2 ' + } L 6 4 4 y r.rr rrrr,,.r..r.r.,,......r.....:......v.........r.,,...,..,.. ...r..r+... — MOUNTING FLANGE, BOOT AND E AUTOMATIC SHUTTER, 3500 CFM AT } , S"' Alklll .,,. 1" SP, HARTZELL SERIES 02, # r , e°qs•";•+••'••� 24" TYPE P13, OR APPROVED EQUAL ' ` FAN MAX. DIM, 28-3/4" 0 AT WALL.� ' t .. .,,,. .....,....................... ..:..,....,..,..n..,.,,. NOTE: EXISTING PUMP AND PIPING NOT t . ....,.. .....n.. ....,,. � n,. ..,,.... .,..................... SECTION rA SHOWN FOR CLARITY. 1 NEW CONDUIT TO SECOND LEVEL SCALE: 1/4"=1 '-0'° PER SHEET 3 LEVEL SENSOR PANEL LANDING PLAN SECOND LEVEL CORE DRILL FOR CONDUIT AND SLEEVE tit PROVIDE RUBBER LINK-SEAL AT BOTH SCALE' 1/4"=1'-0� ENDS. GROUT ALL AROUND, 1"0 SCH, 80 PVC PIPE, THREADED CORE DRILL FOR 1"0 SCH. 80 PVC CONDUIT PENETRATION =- 90" ELBOW, THREADED THREADED SLEEVE PVC THREADED UNION 46'-0" <, I TRANSDUCER DRY WELL :.. .:....w.,.,,....,:..:....:.:.....,.........,.::..,,.:...........,,....,.......:...,.,,,...::::.,.:.v:....:..:...,...,..•:.::..,:...:,w.•:...,:.:.......,,•...:.:.:.,..:.w.,,,..,:,.. ..,,,.........r::.w.:.rv.r......::.:.:.........,..,,...,,....,.,,,,,.....,,,,,,...,,,,:.,,.:.w.,,,,,,.w.,,w.,,::.:.,.,........,•.w.........:.....:.:...,,.,,,.....,,..,:...,,v:.,.....: •5:,, WELL 12" N EXIST. WET LANDING w..:..:.,...:....... F t EL. 2.67 ... .............................,2.. ...... ,................,.....,....... a EL. 18.95 :.....::.::# I F.....,.r...,.............. E n H.W.L. 30 ' L L 1 1,}�-— r 3 16"X16" A.E.G., E 3 I 20"X20" A.E.D. ........v..:... ...::., ,.w.,,,..,.,�w., w.w..,.... a t �...,....... VIEW EL. 11.76 12"X12 A.E.G. : s x. F: F s i s I i 7 £ ""^ i? S TO LEVEL SENSOR PANEL DRY WELL o 0 TWO 3/4" 0 X 4" REDHEAD „ I € I .-+ >5 # I # ,<:^.r} •. DUCT SUPPORT PER SHEET 3 � N�p BOLTS NUTS N v.: ....:., • OL S W USA + , : , } LOCKWASHERS TYP WELDED STEEL BRACKET (TYP) ` FAN : > ' 8'-0" tt n aM is 16"X76 A.E.D. 6. I 12"X32 A.E.G. � F s `E I : 1" SCH, 80 PVC � " I $€ z^ ? PIPE, THREADED N t]. E _ __— EXISTING LOWER LEVEL PUMPS, VALVES ? 1 WET WELL � �° £ ---_ •,:•G+;rj ,. ..iz,E''. ., .. 3 ia,.::..,,:::.::.:.:,.::..,:::.::::..::.:.n.:...,:::ii ..33 k �— C --- PIPING. AND APPURTENANCES, NOT SHOWN ..}M ,.: >. ,3E•: FOR CLARITY, k w. :.,...,:..:...:....., :::.:....,.,.......u..,,,,,., w...,, : .,, ....,. :,,,..,.::::.:.::::.,.. ,..,.r:::::..:.,,,.:::.,,,,.::.......,,:..,E EL. 4.93 } r k _ EXIT, W 12"0 ALUM. DUCT LANDING ' TRANSDUCER MILLTRONICS E I HYDRORANGER I OR EQUAL u�a I EXIST. 8"X8"X16" CONC. BLOCK I : PER SHEET 3 WALL SECTION. REMOVE AS REQUIRED FOR 6" • ... ........................ ...............r..,...::::::::..,:::::::.,,..,.::.,,.::::::::::r:::.,,,.:::::...::::::.�:::::.:::..:..:::::..«r:::..::.:;:::..::....::: :..:::.:..:..:::.....,...::.,.:.,.::::::..:::::::::.. AROUND D OPENING tR co • , FAN INSTALLATION. SEAL I V V WATERTIGHT WITH GROUT. I TRASH RACK ................._ ,,_ ,.r.,,..,.... ..r._ _._,.rr..r. „,.,,......•.r,.....,.......,.,r..,.,...,. ..,. ..,.r:.,., ,.r .. # E PLAN . . .... . . ..... .............. ......... } � a Z, € t �,r"'�•r Lam'''' k E � �f t 2 SECTION B TRANSDUCER SUPPORT r2 '� ' SCALE: 1/4!=l '—(f �`.,,..., ..... r..,......,. �.....,. ....r....,...,...,,,.,..:....,......r.r..r.rrr. ..,,,..... n. ,... _.,. ~^ / NO SCALE .......... .. ..:......,,r.r...........�r.,..r........w....,.......,,..,.r.,,,.,,.,....._.......w�.....r..,.,,.,r......�,..,....,...._....r._.,ww,,..v.,,,..,...,w.,,r...... ................_„rr„w.....,,.....,,,,,,,,,,..�.,,, ... �.w.,,,,,,,.. LLJ LOWER LEVEL NOTE: PROTECTIVE COATING FOR ALL DUCTWORK, GRILLS, SUPPORTS, BOLTS, -'G O LANDING PLAN AND NUTS SHALL BE TNEMEC SERIES 66 (HI—BUILD EPDXOLINE), N4. 49036 z OR EQUAL. COLOR SHALL BE AS REQUIRED BY THE OWNER. � % W (� SCALE: 1/4! =1 i—Cr * e A * W C.D � CO I DRAWN BY: R. H. F BY: APPROVALS z REVISIONS APPROVED DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT N. U. TAILOR. N. U. TAILOR H. FAK OU Y ALS ENCINITAS SANITARY' DISTRICT DWG. NO. w ,� n PLANS PREPARED UNDER SUPERVISION OF RECOM ED APP ED LANS FOR THE IMPROVEMENT OF: HORIZONTAL MOONLIGHT BEACH PUMP STATION E S 18 6 DATE: /O- 7 - 9¢ BY: 8Y: VERTICAL h�N R.C.E. No. 9o3G R.C.E. 1 T ALAN 21869H18ALD VENTILATION AND WET WELL IMPROVEMENTS . � '� R.0 18189 R.C.E. ENGINEER EXP. ��ZG�'G DATE: o - e t - s y DATE: — WORK PROJECT NO.: SHEET 2 OF 3 j UP TO SVAITC14 AT ENTRANCE ELEC. PANEL EXIST. Ak HATCH � Apo N5VI �TA�T E� EXIST. PUMP MOTOR (TYP) 1 J- k15T NG MCC C� 4�OV Bus DISCONNECT rJEMA M oL. ! Q \---° 10- --� b,, NEN CONDUIT PENETRATION _—��' -�X.isT1Ncm MU� RPHY' 1w 0 FI,QM MOTOR ROOM � EXIST. SURGE TANK EXIST. OONT L• JAW E l TO PUMP ROOM DIESEL L�VSL, 5ENSOK2 LEVEL VIELL CONTROL c�NERATOR 3415 I . J J PAN TRANSDUCER EXIST ELEC. ACCESS DOOR CONTROL PANELS Tn WET WELL J STAIRWAY SE�JC)R TO WET WELL o EXIST. 'SKITCH AT r-XH FAN - OL '�)C I eT1 N ICU LE I LANDING T CO P E HTkANC E M h ~ • ' •. PAN D f•••• I � +• • `I. • O OF I . , T«1 ISrG. TRASH RACK \-eX14AUST PAN AUTO P��� � H P, q8O� , U S B TO T�_ !�PT EXIST. AIR WELL TI��N�MITT �� (oUTL� REMOTE THEFkj06TAT 3 PO51TION 5EL,5c, 09 5W ITCH POR eAHAU5T FAN) N CAST FD fox LJ� L.�XH,&, T FAN GOVT RQ S f 1 NO E5 ' L-4- I� I �[-1- I30xEe SNAL.L 5E: CAST FD TYPE , CONDUIT �\ SAL.� 5E g(S C, CONDUCTORS SHALL 5E PF' K THHN,/THWN . �� '� �� 1 2 AL.L. CONpulT9 E,>CITIN 1NETKEFLL. S14AL.L 155 KIOTE- �JeV�O 5E,AL CIP I N ACC ORPANC E Ii�J_ITH NEC, ANTIC LE 5501,/4� 9GC-(5)#lE A-10#12Gi V21 KcAc-(Sri 2- 4K 0# I2G � C00U IT 1 N5TAL.LAT ION SI IAL L 5E PaK N eC AND I NST)kI-L_ L.1 L-T1�A�ONIG ��STEM ,� I NISI GATED ON A - �H P N INq . T E - 0 � IGNAL FROM TH JL- KA 0NI N EGA S�ANpA pS. T TRA.NSM ITTEI� Val I L..L.. ICI II�.EI TO TIDE E�.I�TIII�IG I�UII Go�IpUIT L.AIv�P �H,4LL � t�IALL.EA L.�E 11ZON CONTI OL FA'NEL.,. IN rLAGE OF , I TINS EBIGNAL FROM TI E MOTOR ROOM A L? WeN 5TAJ2 UNIT Doo TYPE- N ITH ia)AGKPLATE. JIFFY CLrIP5 NOT ALLOV� eP, U L_ R T ITT . THE UL.TI AS NIC TRM5MITTeg I5 --- JN Eaxie;TNG T=uFt4Ae sYe 3 I LOCATeP TO,THE L. [T OF= THR MURP14 PANEL-® TPA 4 t MOTOR CONTRO I T I W.TRA ON I C TRANSPLICaR PAL..L . ICE LOcA-"E A OWN { (SEE CO1ATIZO4 1�IAGi A ) ( IN THE VV T I IE.L .- AREA. THE UUT1 A50NI0 PC-VICE 514ALL E 97,� HYDRO ��A M LLTRON ICS N IITH T-14 T JSLJCE • r I THE H`YD O A�4G5 R - T- SHA1,L IN L.L1L E: E A t LI a°x I ►I CURRENT LOOP I�a�I..,A, OFD N E OE A � � L.EG N� = i� �" A I� M �A� Imo' +.�� M M 1 N� S�a pEVIcE . THE ��(STEM WALL® E DELIVERED COMPLETE KITH 0 -� 5TA ,T- UP •T AININ ) CALIa>RA7ioN ANP 755TIW ' IAJITH TAI MURI H"Y F'AN L_ . THE COOKDIN TION OF THE I=INAL_ TE• 7I G I �ON��1T KI I LL_ i3E. 13Y SAN EL I IJO JOINT O E Sr AUTHORITY m � � I I PROCEDURES FOR SWITCHOVER TO ULTRASONIC TRANSMITTER RGC Ki� I� C �LVAN �G D CONDU IT ®� 1. PRIOR TO DISCONNECT OF THE EXISTING 4-20 ma SIGNAL FROM THE Pu M P^ go �,,{ � BUBBLER, THE ANALOG LEVEL SIGNAL OBSERVED AT THE EXISTING �-►1 �If`� t `N MURPHY PANEL WILL BE COMPARED TO THE INDICATED SIGNAL OF THE MCC M OTOIZ G OBIT COL C E I�ITER ULTRASONIC TRANSMITTER.- 2 . FOR TESTING REQUIREMENTS OF THE ULTRASONIC TRANSMITTER VERSUS THE EXISTING BUBBLER UNIT, THE CONTRACTOR SHALL BE RESPONSIBLE LLJ FOR COORDINATING WITH THE ULTRASONIC TRANSMITTER MANUFACTURER THE USAGE OF A TEMPORARY CHART RECORDER TO ALLOW FOR THE DISTRICT OPERATIONS REPRESENTATIVE TO OBSERVE THE READINGS OF < THE EXISTING BUBBLER VERSUS THE ULTRASONIC FOR ONE WEEK PERIOD. ANY RENTAL COSTS FOR THE CHART RECORDER SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONNECTION AND DISCONNECTION COSTS OF THE CHART RECORDER. 3 . ONCE THE TESTS RESULTS HAVE ,BEEN -SATISFACTORY TO THE DISTRICT L jt OPERATION REPRESENTATIVE, THE CONTRACTOR SHALL BE NOTIFIED TO LI MORAES/PHAM & ASSOCIATES * * PERFORM THE CONNECTIONS TO THE EXISTING MURPHY PANEL. LL_I V ! L ._. CT I c�N A - coxsvLTtxc et�cr�rcaL Nr� a� � W _ 4. THE CONTRACTOR SHALL INSURE THAT THE ,BUBBLER REMAINS. Z CAR AD " 92M �3CIh1.. �'-��� — OPERATIONAL BY PROVIDING PROPER TERMINATION OF THE EXISTING �— G crew c� X2008 - t $2_ '"nr� - 4-20 ma SIGNAL AS REQUIRED AND APPROVED BY THE DISTRICT, �✓ [� REVISIONS APPROVED DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT = APPROVALS ENCINITAS SANITARY DISTRICT DWG. NO. WQC PLANS PREPARED UNDER SUPERVISION OF RECOM D APP PLANS FOR THE IMPROVEMENT OF: HORIZONTAL MOONLIGHT BEACH PUMP STATION E S 18 6 DATE: /0- 7- 10 BY: - BY: LL J. ALAN D. ARCHI Umn L VERTICAL (` wy .�,-�® R.C.E. No. ¢'®3� R.C.E. 18189 R.C.E. 21869 VENTILATION AND WET WELL IMPROVEMENTS ENGINEER EXP. G/ZG /!G DATE: `O—s Z-- 9 K DATE: b.4ti WORK PROJECT NO.; =EUT3 OF 3