Loading...
1999-6181 I (Plans) I , GENERAL IMPROVEMENT NOTES WORK TO BE DONE 1. A PERMIT SHALL BE OBTAINED FROM THE ENCINITAS ENGINEERING SERVICES DEPARTMENT FOR THE IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE ACCORDING TO THESE ANY WORK WITHIN THE STREET RIGHT-OF-WAY. PLANS AND THE SPECIFICATIONS AND STANDARD DRAWINGS OF THE CITY OF ENCINITAS. 2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH CITY OF ENCINITAS PUBLIC ROAD STANDARD SPECIFICATIONS: - ! STANDARDS. R VALUE TESTS SHALL BE REQUIRED PRIOR TO CONSTRUCTION. 1. STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 1997 EDITION , - - --- INCLUDING THE REGIONAL AND THE CITY OF ENCINITAS SUPPLEMENT AMENDMENTS, -- 3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY. STANDARD DRAWINGS: - 4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT-OF-WAY SHALL BE CONSTRUCTED, 1. SAN DIEGO AREA REGIONAL STANDARD DRAWINGS, DATED MARCH, 1997. CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER AND PAVING. - - - - - 5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, 1 ; THERE ARE NO OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER, THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING z FACILITY SHOWN HEREON AND ANY OTHER WHICH IS NOT OF RECORD OR NOT SHOWN ON THESE LEGEND ( I I PLANS. DESCRIPTION STD DWG SYMBOL QUANTITY ® 6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE DONE SHALL BE _ a ) ( 6% CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. CONTRACTOR WILL MAKE EXPLORATORY EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES 3 -- --- - - ' WIDE CONCRETE SWALE - N= "^:.. � 50 LF SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE - - _ NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES. N. O � - -' - a o L to ASPHALT ALLEY PAVEMENT 600 S.F. 7. THE CONTRACTOR SHALL NOTIFY SAN DIEGO GAS AND ELECTRIC COMPANY PRIOR TO STARTING N + - r - r- C - WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE WORK WITH COMPANY " w rn: - d 1 REPRESENTATIVES. ASPHALT OVERLAY 80 S.F.t " - w �� _ .W 0 6 H I ^ ..M N,z NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT " X:� + o + o o 1 WATER SERVICE _ o . Q, rn ARE "UNDERGROUND INSTALLATIONS". FOR LOCATION OF W 3 EA. z Zi ELECTRICAL CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE SAN DIEGO GAS & ELECTRIC COMPANY. TRENCH RESTORATION 5 L.F. ( v C4, TELEPHONE:(800) 422-4133 I + m ,. ADJUST EXIST. WATER METER BOX 1 EA. �" - _ __ - B. THE CONTRACTOR SHALL NOTIFY PACIFIC BELL PRIOR TO STARTING WORK NEAR COMPANY � FACILITIES AND SHALL COORDINATE WORK WITH COMPANY REPRESENTATIVES. - - - ro NOTICE: ALL TELEPHONE SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND INSTALLATIONS". FOR LOCATION OF CABLES AND APPURTENANCES CONTACT - - - - PACIFIC BELL. TELEPHONE: (800) 422-4133 ! _ _.. _ v - _� a__ XI GRADE ' FINISH GRA E ® C OF ALLEY 9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTACT THE UTILITY AGENCIES, ADVISE :CL OF AELEY - THEM OF THE PROPOSED IMPROVEMENTS, AND BEAR THE COST OF RELOCATIONS, IF NEEDED. - - - - 10. ALL TELEVISION SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND INSTALLATIONS'. FOR LOCATION OF CABLES AND APPURTENANCES CONTACT (800) 422-4133. SITE ADDRESS 11• IMPROVEMENT DRAWINGS. ALL SERVING LOCATED WITHIN THE DEDICATED S BUILT" CARDIFF,3CA 92007 MANCHESTER AVE. \R��NGNPM RIGHT-OF-WAY, OR WITHIN EASEMENTS DEDICATED TO THE CITY OF ENCINITAS. 9 �o ;� �y� ASSESSORS PARCEL NO. G v�oo `�. ----- -- -- _--- - - --� --°- -- -- - ° - 12. NO PAVING SHALL BE DONE UNTIL EXISTING POWER POLES ARE RELOCATED OUTSIDE THE AREAS 00 1 TO BE PAVED. 261-062-01 THRU 03 N y�� 2oy� c'o ho TOPOGRAPHY BY: 13. ALL LUMINAIRES SHALL PROVIDE TRUE 90' CUTOFF, AND ALLOW NO ESCAPE OF LIGHT ABOVE THE HORIZONTAL. PENNY ENGINEERING �� OR' v-, . I�°-° --- - ------_ ALLEY PROFILE _ ZER v� r �\6 � `: � 14. THE CONTRACTOR SHALL REQUEST FROM THE ENGINEERING SERVICES DEPARTMENT A SUITE L 8400 N. MAGNOLIA AVE. NES _ SCALE: 1"=10 HORIZ.; 1"=2 VERT. PRE-CONSTRUCTION MEETING AND SHALL PROVIDE AT LEAST 48 HOURS OF NOTICE FOR SUCH A SANTEE, CA 92071 101 < 1tOO 1+50 2+00 ?MEETING. PHONE NUMBER 633-2770. DATED: MARCH 9, 1999 0 15. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCH MARK WHICH IS OWNER/APPLICANT PROJECT SITE ,DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL `ENGINEER OR A LICENSED LAND SURVEYOR. SEA COAST HOMES, LLC VINCINITY MAP 16. THE DEVELOPER SHALL MARK THE LOCATION OF EACH SEWER LATERAL AND WATER SERVICE BY 6496 WEATHERS PLACE, SUITE 200 NO SCALE CHISELING THE LETTERS "S" AND "W", RESPECTIVELY, 2 INCHES HIGH INTO THE FACE OF THE SAN DIEGO, CALIFORNIA 92121 CURB. 17. THE ADDRESS OF EACH LOT SHALL BE PAINTED ON THE CURB IN A MANNER AND LOCATION APPROVED BY THE INSPECTOR. M N 18. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC r WORKS CONSTRUCTION (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE N STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (ADOPTED BY THE C� SAN DIEGO REGIONAL STANDARDS COMMITTEE), AND THE SAN DIEGO REGIONAL STANDARD 77 DRAWINGS (LATEST EDITION). OWNER CERTIFICATION co cn LR V N x i? ATION + w - I HEREBY AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS SHOWN ON TH ESE z TEMPORARY BENCH MARK PLANS WITHIN EXISTING CITY RIGHT-OF-WAY WITHIN 60 DAYS AFTER moo ATION ISSUANCE OF THE CONSTRUCTION PERMIT AND TO PURSUE SUCH WORK a PRIOR 0 THE ELEVATIONS PROVIDED HEREON ARE BASED ON TOPOGRAPHIC SURVEY ACTIVELY ON EVERY NORMAL WORKING DAY UNTIL COMPLETED, IRRESPECTIVE CTION PERFORMED BY PENNY ENGINEERING ON MARCH 9, 1999. SAID SURVEY UTILIZED A AND INDEPENDENT OF ANY OTHER WORK ASSOCIATED WITH THIS PROJECT OR 0p W TEMPORARY BENCH MARK/REFERENCE POINT BEING THE TOP OF CURB ON THE UNDER MY CONTROL. �1 �5 EXIST. 3' ADJUST EXIST. �X�� pg �g G % EASTERLY SIDE OF MANCHESTER AVENUE AT THE INTERSECTION OF A g5 g5 EXIST. CONC. �g WM BOX TO g1• sy� Nl �k N4 g0 0 PROLONGATION OF THE SOUTHEASTERLY LINE OF LOT 39, BLOCK 29, MAP 1298. SEA COAST HOMES, LLC ASPH. SWALEI g��Q NEW GRADE ELEV. 79.70 ` - 3 APPROX. LOCATION OF BY: ��6 ' 12/13/99 I k00�I\S�' 6" A.C. WATER MAIN a - - - - - - i - - - - - 3 s b 1�p\� gpti R TO VERIFY gp0 CONTRACTOR 6496 WEATHERS PLACE, SUITE 200 LOCATION r h SAN DIEGO, CA 92121 -G ` G- G- G- Z O - - - - - - ASSESSORS PARCEL NO.: 261-062-01 THRU 03 FV W F� W C1N W W W F g01 Q W N30'38'59"W �j� ,. 75.01' pfk Z ~ 1 C3 �k5�EG ` FG a- o ASPH. OVERLAY EXIST. BLOCK `gp S g�5 W N DECLARATION OF RESPONSIBLE CHARGE g1' �, AS REQUIRED WALL ��� + TO PROVIDE SMOOTH W IMPORTANT NOTICE En 07 W TRANSITION Z W (MIN. 5 TRANSITION . ' Section 4216/4217 of the Government ' 6°0 w a a U.1 LENGTH) (� Code requires that o Dig Alert Identification I, JOSEPH G. CRESTO HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I I\r� N °' I\ 3 ° I °' 3 ° 3 r��� r2� r�� W Q Number be issued before a HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 �3 M r3 N N �� ° ° 7 o a, +� + + "Permit to Excavate" will be valid. OF THE BUSINESS AND PROFESSIONS CODE, AND THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. s � + + N orn For your Dig Alert I.D. Number Call �y z W W W un O1 Underground Service Alert I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF ENCINITAS IS !� o r z r� Fh 0 a CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME OF MY RESPONSIBILITIES FOR PROJECT DESIGN. f, f� f� TOLL FREE 1-800-422-4133 ��� + 1 ,\� I 7.5' 7.5' co W 0 Two working days before you dig �J S W a o CJ , 6' 3' 6' 0 Q U) JOSEPH . CRESTO � UPPER 12" OF 1.5' 1.5 PROJECT V r R.C.E. NO. 45601 oQROFESS/pN9l SUBGRADE TO 2q MIN " 2� MIN SITE W ���� �Q\A G• C,p� F� BE COMPACTED 1.5 . _ STEVENS CRESTO ENGINEERING, INC. �i P - - 9620 CHESAPEAKE DRIVE, SUITE 107 p Z TO 95% RELATIVE "> Z U (p c, m COMPACTION. W SAN DIEGO, CA 92123-1324 W No. 45601 � 7 - T rrr - r EW CONC. > Q .-. T(-I -I - r 5//WSTEVENS-CRESTO ENGINEERING, INC. Exp. 12-31-02 CONCRETE SWALE CONC. SWALE DRIVEWAY W N 00 PHONE (858) 694-5660 • ASPH. PAVEMENT SEE NOTE AT 0 CIVIL ENGINEERS•LAND PLANNERS•SURVEYORS JT CI Vll �Q THICKNESS: 7 F- tD 9� � • CONCRETE: 560-C-3250 AND BASE PER LEFT y � � OF CALF • SEE RSD G-13 FOR OTHER CITY STDS. 9620 CHESAPEAKE DRIVE PHONE: 858.694.5660 CONSTRUCTION DETAILS (MIN. 3" AC/6" AB) SUITE 107 FAX: 858.694.5661 - • SEE RSD G-9 FOR SPACING TYPICAL ALLEY SECTION L1"I SAN DIEGO,CA 92123-1324 www.scengr.com OF JOINTS. NO SCALE DESIGNED BY DRAWN BY CHECKED BY CITY O F ENCINITAS a REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE SAN DIEGUITO WATER DISTRICT G APPROVALS ENGINEERING DEPARTMENT DRAWING N0. Z PLANS PREPARED UNDER THE SUPERVISION OF: RECOMMENDED APPROVED ALLEY IMPROVEMENT PLAN FOR: N DESCRIPTION: HIGHWAY 101 BRIDGE HORIZONTAL \ N Z #A78-81 ® SAN ELIJO LAGOON 1"=10' REVIEWED BY: W- --- ®® ` 6181-I W Co CROSSING. N.E. CONCRETE WING WALL DATE: It/qkm BY: • Mal- BY: N LOTS 39-41, BLOCK 29, MAP 1298 Z cc z VERTICAL W/SID. DISC STAMPED OC-136. 1968 DATE: Z a'1 oD RCE N0. 45601 080 ELEV.: 14.793 DATUM:USC&GS 1"=2' SIGNATURE EXPIRES TWO YEARS FROM DATED SIGNED JOS H CRESTO EXP. 12/31/2002 DATE: �j �Zo/OQ DATE: DD WORK PROJECT N0. DR 98-202 SHEET 1 OF 1 a SCE PROJECT 99033.01