Loading...
6977 LA COSTA AVE PLANS FOR THE CONSTRUCTION OF ` ANDREW AVENUE STREET IMPROVEMENTS ; . \ 1 a� ; i t t PROJECT � � IXI ; E CITY OF ENCINITAS LOCATION LUCK L I/2 " ( _1� ; rI I r ' jh7 , t s L_0 . w ��oPO g GENERAL NOTES FIRE DEPARTMENT NOTES \V\ L 2 , Ut i` ' 1. A NO FEE PERMIT SHALL BE OBTAINED FROM THE CITY OF ENCINITAS ENGINEERING DEPARTMENT FOR ANY WORK WITHIN 1. ALL EXISTING FIRE HYDRANTS WILL BE REPLACED WITH HYDRANTS OF A BRONZE TYPE AND SHALL - - 1 THE STREET RIGHT-OF-WAY. HAVE TWO (2) 4" OUTLETS AND ONE (1) 2 1M' OUTLET. THE HYDRANT SHALL MEET CURRANT FIRE / t 0 2. THE STRUCTURAL SECTION SHALL BE AS SHOWN ON THESE PLANS. DEPARTMENT STANDARDS FOR COMMERCIAL FIRE HYDRANTS. � \` -,, " ENI( IjyITA31 VD i j 3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE ' 2. CURBS ON STREETS HAVING ON-STREET PARKING SHALL RECEIVE RED STRIPING EXTENSIONS 15' I VVV t ✓l_a, ' THE PROJECT BOUNDARY. EACH SIDE OF THE HYDRANT AND SHALL MEET ENCINITAS FIRE DEPARTMENT STANDARDS. 1 4. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE OBTAINED BY A I 3. CONTRACTOR TO INSTALL BLUE RAISED PAVEMENT MARKERS AT FIRE DEPARTMENT CONNECTIONS 51' F 1 4 C SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO OTHER EXISTING FACILITIES EXCEPT TO MEET ENCINITAS FIRE DEPARTMENT STANDARDS. ( i AS SHOWN ON THESE PLANS. HOWEVER, THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT I ' I ANY EXISTING FACILITY SHOWN HERON AND ANY WHICH IS NOT OF RECORD OR NOT SHOWN ON THESE PLANS. 5. THE LOCATION AND ELEVATION OF IMPROVEMENTS TO BE JOINED BY WORK PROPOSED HERON SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. THE CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS NTA dEl AND LOCATION ALL EXISTING UNDERGROUND FACILITIES, PRIOR TO THE START OF ANY WORK, WHICH CROSS NEW STORM ASj<<C `I '� DRAIN PIPE PROPOSED BY THIS PROJECT, SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS, IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES. s 6. a. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS & ELECTRIC COMPANY PRIOR TO STARTING WORK NEAR T r E : r- COMPANY FACILITIES AND SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES. TRAFFIC CONTROL NOTES \ ? NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE `UNDERGROUND INSTALLATIONS." FOR GHAM DR LOCATION OF ELECTRICAL CABLES AND GAS PIPING AND APPURTENANCES CONTACTS THE SAN DIEGO GAS & ELECTRIC 1.TRAFFIC CONTROL SHALL BE IN ACCORDANCE WITH SECTION 7-10 OF THE STANDARD SPECIFICATION, {T< t 3. I t COMPANY. SPECIAL PROVISIONS AND CALTRANS MANUAL OF TRAFFIC CONTROLS FOR CONSTRUCTION AND PROJECT TELEPHONE: (800) 422-4133 MAINTENANCE WORK ZONE (1985 EDITION). b. THE CONTRACTOR SHALL NOTIFY THE PACIFIC TELEPHONE COMPANY PRIOR TO STARTING WORK NEAR COMPANY 2.ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES. LOCATION \ \'- FACILITIES AND SHALL COORDINATE WITH COMPANY REPRESENTATIVES. 3.ALL TRAVEL LANES WILL BE A MINIMUM OF 12' WIDE UNLESS OTHERWISE SHOWN. 1 ' y' TELEPHONE: (619) 546-3606 4.PEDESTRIAN FLOW WILL NOT BE DISTURBED UNLESS OTHERWISE SHOWN. c. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGUITO WATER DISTRICT PRIOR TO STARTING WORK NEAR COMPANY 5.THE CONTRACTOR SHALL NOTIFY ALL ADJACENT PROPERTY OWNERS AND TENANTS OF THE ;\ .M FACILITIES AND SHALL COORDINATE WITH COMPANY REPRESENTATIVES. PROPOSED POSSIBLE TRAFFIC DETOURS AT LEAST 72 HOURS PRIOR TO COMMENCING WORK. • 9 NOTICE: FOR THE LOCATION OF WATER DISTRICT FACILITIES WITHIN THE PROJECT AREA TELEPHONE: (760) 633-2709. 6.ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES DURING J d. THE CONTRACTOR SHALL NOTIFY COX CABLE TELEVISION COMPANY PRIOR TO STARTING WORK NEAR COMPANY PROJECT CONSTRUCTION. FACILITIES AND SHALL COORDINATE WITH COMPANY REPRESENTATIVES. LOCATION MAP NOTICE: FOR LOCATION OF CABLES AND APPURTENANCES CONTACT COX CABLE TELEVISION COMPANY. TELEPHONE: (800) 422-4133 SCALE: 1"=100' 7. CONTRACTOR SHALL RELOCATE ALL INTERFERING TRAFFIC SIGNS AS DIRECTED BY THE CITY INSPECTOR. 8. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTIONS VICINITY MAP (LATEST EDITION), THE SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (ADOPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE), THE SAN DIEGO REGIONAL STANDARD NOT TO SCALE DRAWINGS (LATEST EDITION), AND THE SPECIAL PROVISIONS FOR THIS PROJECT. 9. ALL PRIVATE IMPROVEMENTS IN THE PUBLIC RIGHT-OF-WAY DESIGNATED TO BE REMOVED SHALL BE SALVAGED AND RETURNED TO THE PROPERTY OWNER. ALL PRIVATE IMPROVEMENTS OUTSIDE THE PUBLIC RIGHT OF WAY DAMAGED BY THE CONSTRUCTION OF THE PROJECT SHALL BE REPAIRED BY THE CONTRACTOR. 10. THE CONTRACTOR SHALL PROTECT EXISTING LANDSCAPING AND IMPROVEMENTS REMAINING IN PLACE. 11.THE CONTRACTOR SHALL BE RESPONSIBLE THAT ANY MONUMENT OF BENCHMARK WHICH IS DISTURBED OR DESTROYED SHALL BE RE-ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. A CORNER RECORD, CERTIFICATE OF COMPLIANCE OR RECORD OF SURVEY SHALL BE FILED AS REQUIRED BY THE LAND SURVEYOR'S SHEET INDEX ACT. THE CONTRACTOR SHALL FURNISH, TO THE CITY OF ENCINITAS, PROOF OF RECORDING. 12. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT-OF-WAY SHALL BE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER AND PAVING. NOTE 13. THE CONTRACTOR SHALL REQUEST FROM THE CITY ENGINEER'S OFFICE A PRE-CONSTRUCTION MEETING AND SHALL SHEET NO. SHEET DESCRIPTION PROVIDE AT LEAST 48 HOURS NOTICE FOR SUCH A MEETING, CALL 760-633-2770. 1 TITLE SHEET, SHEET INDEX, AND NOTES RIGHT-OF-WAY LINES, AND EXISTING EASEMENTS SHOWN 14. THE CONTRACTOR SHALL MAINTAIN ADEQUATE DUST CONTROL MEASURES THROUGHOUT THE DURATION OF THE HEREON WERE ESTABLISHED FROM AVAILABLE RECORD MAPS. PROJECT CONSTRUCTION. PROJECT SITE MAINTENANCE SHALL CONFORM TO SECTION 7-8 OF THE STANDARD 2 ANDREW AVENUE STREET IMPROVEMENT PLAN NO TITLE REPORTS WERE PROVIDED OR REVIEWED FOR THIS SPECIFICATIONS. PROJECT AREA. SELECT RECORD MONUMENTS WERE TIED INTO 15. THE CONTRACTOR SHALL MAINTAIN A SET OF "AS-BUILT" DRAWINGS ON WHICH ALL CHANGES OR VARIATIONS IN THE THE PROJECT COORDINATE SYSTEM TO ORIENTATE THE RECORD WORK, INCLUDING UTILITIES, ARE TO BE RECORDED. A COPY OF SAID "AS-BUILT" DRAWINGS SHALL BE PROVIDED TO THE CITY OF ENCINITAS WHEN REQUESTED. MAP. BEARINGS AND DISTANCES FROM THIS DRAWING REPRESENT A BEST FIT COMPILATION OF RECORD DATA. THESE 16. MATERIAL OR DEBRIS SHALL NOT BE STORED OR REMAIN IN THE PUBLIC RIGHT-OF-WAY WITHOUT APPROVAL BY THE CITY ENGINEER. PROPERTY LINES AND RIGHT-OF-WAY LINES ARE INTENDED TO 17. OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) NOTE: THE CONTRACTOR IS REQUIRED TO OBTAIN A a_ BE USED FOR A GRAPHIC REPRESENTATION ONLY. PERMIT FROM OSHA PRIOR TO COMMENCING CONSTRUCTION OF TRENCHES OF EXCAVATIONS WHICH ARE 5 FOOT OR DEEPER o AND INTO WHICH A PERSON IS REQUIRED TO DESCEND. di N O LEGEND SYMBOL N STATEMENT OF ENGINEER OF WORK N EXIST. R/W _ _ _ DI RT EXIST. G.L. THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY EXIST. CONTOUR �-m � WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEER'S TRADE OR ` ' -° PROFESSION. THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN EXIST. SIGNS ACCORDANCE WITH THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, TO THE EXTENT THAT THE ENGINEER CONTROLS SUCH PERFORMANCE. THE ENGINEER AGREES THAT ANY EXIST. FENCE PLANCHECK OR REVIEW PERFORMED BY THE CITY OF ENCINITAS IN ITS CAPACITY AS A PUBLIC ENTITY FOR THE PLANS PREPARED BY THE ENGINEER IS NOT A DETERMINATION BY THE CITY OF ENCINITAS OF EXIST. WATER MAIN BASIS OF COORDINATES ENGINEER OFARESPONSIBILITYOFOR THE PLANS EORNDESIGN OFHIMPROVEMENTS BASE THEREON.H HEREONHTHE EXIST. SEWER MAIN W M CALL TOLL FREE NAD 83 (1991.35 EPOCH) ENGINEER AGREES TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS AND ITS OFFICERS, EXIST. GAS LINE S o 1 -8��-227�26�U AGENTS, AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE C U v V ENC-33 PT N0. 1033 NEGLIGENT ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS/HER AGENTS OR EMPLOYEES EXIST. ELECTRIC LINE E ( ) ACTING WITHIN THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE S C a EXIST. TV N 1957888.951' WORK PERFORMED BY THE ENGINEER. CTV o TWO E 6242388.878' EXIST. TELEPHONE T WORKING DAYS ELEV 82.081' (NAND 88) SIGNATURE: DATE: 92 l BEFORE YOU RECORD OF SURVEY 18416 EXIST. STORM DRAIN DIG COMPANY: DUDEK PROP. DG PATH 2.5 CITY OF ENCINITAS BRASS DISC IN " CURB ON THE SOUTH SIDE OF THE PARKING ADDRESS: 605 THIRD ST. ENCINITAS, CA 92024 Underground Service Alert LOT FOR THE CITY OF ENCINITAS SWAMIS PHONE NUMBER: 760-942-5147 PROP. AC PAVING SECTION ofSouthemCalifomia PARK IN RED CURB NORTH OF RESTROOMS. RCE EXPIRES: 12/31/2013 > a FINISH SURFACE rofiq. 12/31 SAN DIEGUITO WATER DISTRICT TOP OF BERM ceD V D E K TOP OF WALL* Dudek&Associates, Inc. Z 605 Third Street Encinitas, CA 92024 a civ11- @� 760.942.5147 Fax 760.632.0164 REVIEWED BY DATE: c P OF CA��F� SIGNATURE EXPIRES 2 YEARS FROM DATE SIGNED CWW10A-2 w REVISIONS APPROVED DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT MH MH I MH APPROVALS CITY OF ENCINITAS ENGINEERING DEPARTMENT DRAWING NO. ENC-25 (PT N0. 1025) ELEV 60.601' (NAND es) PLANS PREPARED UNDER SUPERVISION OF RECOMMEN ED _ APPROVED TITLE SHEET FOR: RECORD OF SURVEY 18416 HORIZONTAL AS SHOWN DATE: oZ ( gY: BY: � ANDREW AVENUE $9-SI ° 2.5" CITY OF ENCINITAS BRASS DISC IN WELL w MONUMENT IN THE MIDDLE OF THE INTERSECTION OF VERTICAL NONE R.C.E. N0. 59395 EDWARD DEANE GREG SHI D STREET IMPROVEMENTS SOUTH EL PORTAL STREET AND LA MESA AVENUE, RUSSELL J. LZ DATE: Z^27' ZD�Z o 100 FEET NORTH ALONG THE SOUTHEASTERLY CURB EXP. 2/31/1113 DATE: Z^ '1¢�^ZDfZ j LINE OF SOUTH EL PORTAL STREET. SHEET 1 OF 2 STORM WATER POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION ACTIVITY CONCRETE WASHOUT *TEMPORARY VEGETATION MUST BE PLANTED ON SLOES OR *NO SEEPAGE FROM DUMPSTERS SHALL BE DISCHARGED INTO *CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR THE STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND SIZED CONCRETE WASHOUT AREA TO CONTAIN WASHOUT EROSION CONTROL PURPOSES. EROSION SHALL BE PREVENTED DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. WASTES ON SITE. IT IS ILLEGAL TO WASH CONCRETE, SLURRY, BY PLANTING FAST-GROWING ANNUAL AND PERENNIAL GRASSES DUMPSTERS SHALL BE CHECKED FREQUENTLY FOR LEAKS. MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE TO SHIELD AND BIND THE SOIL. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES. STORMWATER CONVEYANCE SYSTEM OR ANY RECEIVING WATER. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN CONTRACTOR SHALL POST A SIGN DESIGNATION THE WASHOUT *PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH LOCATION. EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY TRASH \ MATERIAL. A CONSTRUCTION SITE ACCESS *WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. \w *MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, *A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE WATER-BASED PAINTS, VEHICLE FLUIDS, BROKEN ASPHALT AND PROVIDED FOR VEHICLES EGRESS AND INGRESS TO PREVENT ON-SITE CONSTRUCTION MATERIAL STORAGE CONCRETE, WOOD, AND CLEARED VEGETATON CAN BE TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL RECYCLED. NON-RECYCLABLE MATERIALS MUST BE TAKEN TO SUCH AS GRAVEL AND/OR CORRUGATED STEEL *STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE AN APPROPRIATE LANDFILL OR DISPOSED OF AS A HAZARDOUS PANELS/PLATES. TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL WASTER. FOR INFORMATION ON DISPOSAL OF HAZARDOUS STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE CONSTRUCTION VEHICLES THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY AT (800) 714-1195. FOR INFORMATION ON LANDFILLS AND TO CONTAINMENT FOR ALL FUEL STORED ON SITE. ORDER DUMPSTERS CALL EDCO AT (760) 436-4151. *A SPECIFIC AREA AWAY FROM GUTTERS AND STORMDRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLES PARKING, *ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON SITE. STOCKPILES MAY INCLUDE SOIL, POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE BASE, TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. ALL MAJOR REPAIRS SHALL BE MADE OFF SITE. ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER FLOWS AND STORMDRAIN INLETS. PORTABLE TOILETS MUST IN GOOD WORKING ORDER AND EROSION CONTROL STOCKPILES SHALL BE COVERED OR PROTECTED WITH SOIL CHECKED FREQUENTLY FOR R LEAKS. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE PORTABLE *EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY TOILETS AWAY FROM STORMDRAIN INLETS ON PERVIOUS SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. SURFACES. PROTECTED AGAINST EROSION BY INSTALLING EROSION TRAINING RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, *ALL CONTRACTOR DEBRIS SHALL BE KEPT AWAY FROM THE ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER STREET, GUTTER, AND STORMDRAIN. CONTRACTOR MUST MATRIX. *CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR TRAVELED AWAY FROM CONSTRUCTION SITE STORMWATER *NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED WITH THE CITY OF ENCINITAS STORMWATER POLLUTION CONTROL POLLUTION CONTROL BMP NOTES RELATIVE TO CONSTRUCTION DURING WET WEATHER. REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO ACTIVITIES. EVERYONE WORKING ON SITE. THE PROPERTY OWNER(S) AND *DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS FOR MORE INFORMATION ON STORMWATER POLLUTION CONTROL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL ABOUT STORMWATER REQUIREMENTS AND THEIR OWN MEASURES AND REQUIREMENTS PLEASE CONTACT THE PROTECT CHANNELS AGAINST EROSION USING PERMANENT AND RESPONSIBILITIES. ENGINEERING DEPARTMENT, CITY OF ENCINITAS AT (760) TEMPORARY EROSION CONTROL MEASURES. 633-2770. WASTE MANAGEMENT *REMOVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN *CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL DISPOSING OF ALL WATER AND UNUSED CONSTRUCTION GROUND COVER. DO NOT REMOVE TREES OR SHRUBS MATERIALS. DUMPING OF UNUSED OR WATER PRODUCTS ON THE UNNECESSARILY, THEY HELP DECREASE EROSION. GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED, 216-063-47 OWNER: DAHYA L. PATEL & SHANTA PATEL ADDRESS: 1905 LEUCADIA SCENIC CT 216-072-08 CONSTRUCT LANDSCAPE WALL, OWNER: BETSEY N. MEYER TRUST , HIGH MAX., SEE NOTE 2 CURB AND BERM DATA TABLE ADDRESS: 460 ANDREW AVE CONSTRUCT TYPE 3 NO. DELTA RG. RADIUS LENGTH REMARKS N V x ' EXISTING UTILITIES TO E �° "A" AC BERM PER 5> EXISTING GRADE CnG j BE RELOCATED BY S.D. AC B G-5 6=40'24'35" 25.80 18.19 CONCRETE CURB UTILITY COMPANIES AWCUT' LINE, / /\� 2 N07.24'31"W 2.65 CONCRETE CURB s MATCH XISTING "°° NEW AC PAVEMENT, 2% MIN. /�i� N0T24'31"W 18.61 AC BERM � � � �� CONSTRUCT 53 LFt �. 1 SEE NOTE 3 CONSTRUCT 19 LFf �/. 4 6=37.58'56" 20.00 13.26 AC BERM $ ' LANDSCAPE WALL, 3' 1 21s-o72-07 �> I LANDSCAPE WALL 3 OWNER: CHRISTINE C. BISHOP 5 6=2819'52" 20.00 9.89 AC BERM d ;� HIGH MAX., SEE NOTE 2 � HIGH MAX., SEE NOTE 2 ADDRESS: 466 ANDREW AVE CONSTRUCT 5' WIDE PATH 4" DG 6 NO2'1 4'33"E 4.97 AC BERM �� 'd 't �i��i �\ Jr. '; p o CO S / OVER 6" CLASS 2 AG (TYP) N13'14'02"E 14.68 AC BERM o s �'o• = SECTION A—A 8 - „ MATCH EXISTING Ik _ CONSTRUCT 5 WIDE 6-19 54 06 21.00 7.29 AC BERM o '� p� °` 'Yr = - l SCALE: 1"-2' N 9 N 1974888.45 ,� 2 '� '`7 : , PATH, 4" DG OVER 6" = o N33 08 08 E 14.39 AC BERM 4 E 6240094.2 CLASS 2 AG (TYP) CONSTRUCT TYPE ` r ? r "Coo PEDESTRIAN y:...? ,:.::- c �\— 3 r RAMP PER ____ _ REDWOOD HEADER r. -- ��,� CONSTRUCT 26 LFt S.D.R.S.D. G-�9 T S g N DI RT � � �� x '"- .. , EXIS NG POWER o fi, 0 POLE SE N TE 6 0 �� p-G ,� 6 Y, \ � •.� Q �•��.y^� � NEW-AC � ��s`l�4 �' _ NOTES: 1. REMOVE AND DISPOSE OF EXISTING VEGETATION AS REQUIRED TO N, SEE NOTE 3 �� CONSTRUCT NEW PATHWAY IMPROVEMENTS. NEW PATHWAY SHALL HAVE 3' e d CONSTRUCT 49 LFt \ ��� SEE NOTE 1 cT F ` CLEAR FROM POWER POLE CALL TOLL FREE _ ��(EE= BERM - - �_ o� g 1 -800-227-2600 PER S.D.R.S.D. G-5 - c . A STING 2 CONSTRUCT SEGMENTED BLOCK WALL, DARK GRAY IN COLOR, KEYSTONE o s RELOCATE EXISTING 9 w OR APPROVED EQUAL. MAILBOX BEHIND BERM Two R E Vlf AVE \ CONSTRUCT 36 L cry 3. REPLACE EXISTING AC PAVEMENT WITH 4" AC OVER 6" CLASS 2 AB. o WORKING DAYS c�� - =— -- - TYPE "A" AC BERM BEFORE YOU / x 4. ALL UTILITIES SHOWN ARE APPROXIMATE LOCATIONS ONLY. ALL UTILITY ° DIG / tom PER S.D.R.S.D. G-5 \ LATERALS MAY NOT BE SHOWN. THE CONTRACTOR SHALL VERIFY ALL o VERTICAL AND HORIZONTAL LOCATIONS BY UTILITY MARK-OUT, AND ° POTHOLING PRIOR TO CONSTRUCTION. Underground Service Alert /��. j �` 3�- � �, ; �� � � of Southern California 5. EXISTING CONCRETE IN ANDREW AVE. IS BETWEEN 6" & 8" THICK. Q DETAIL 1 Z QROFESS/pyq SAN DIEGUITO WATER DISTRICT 6. CONDITION OF EXISTING POWER POLE TO BE INSPECTED AND POTENTIALLY J �Fy DUDEK REPLACE SCALE: 1" 1Q' VAR BY UTILITY COMPANY. CONTRACTOR TO PROTECT POWER POLE Q A GRAPHIC SCALE DURING CONSTRUCTION OF SIDEWALK AND RAMP. V-) Dudek&Associates, Inc. * No. 395 * Z• /Z s Ezp. 12 31/N r 605 Third Street Encinitas, CA 92024 Z 7 9T CIVII Q�` REVIEWED BY ' F p 760.942.5147 Fax 760.632.0164 OF CA��E DATE' SCALE: 1" = 10' SIGNATURE EXPIRES 2 YEARS FROM DATE SIGNED CWW10A-2 REVISIONS APPROVED DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT MH MH MH APPROVALS CITY OF ENCINITAS ENGINEERING DEPARTMENT DRAWING N0. RECORD OFT SURVEY 18416 HORIZONTAL 60.601' (NAND 88) HORIZONTAL AS SHOWN PLANS PREPARED UNDER SUPERVISJON OF RECOMMEN D APPROVED PLAN AND PROFILE FOR: 2.5" CITY OF ENCINITAS BRASS DISC IN WELL DATE: I BY; �^_^' - MONUMENT IN THE MIDDLE OF THE INTERSECTION OF "C BY: /�����y �J/ dJ ANDREW AVENUE y J SOUTH EL PORTAL STREET AND LA MESA AVENUE, VERTICAL NONE R.C.E. NO. 59395 EDWARD DEANE G EG SH S—" w 100 FEET NORTH ALONG THE LINE OF SOUTH EL PO TAL STREET.HEASTERLY CURB RUSSELL J. GH Z EXP. 12/31 IV I3 DA1r; L • Z7-ZOtZ DATE: Q -'L$ 7�/Z STREET IMPROVEMENTS o SHEET 2 OF 2