Loading...
1478 WORK TO BE DONE _ o THE TMPROVEMENTT TO BE ACCOMPLISHED UNDER THIS CONTRACT CONSISTS, IN GENERAL, OF THE FOLLOWING "WORK TO 'd BE DONE" IN ACCORDANCE WITH THESE PLANS, THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS, THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (1979), THE 1979 SAN DIEGO STANDARD SPECIAL PROVISIONS TO J THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ADOPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE, AND THE SPECIAL PROVISIONS SHOWN BELOW: G ATE LEGEt-I D D � d 1. THE CONSTRUCTION OF 8`° VCP (OR PVC) SEWER MAIN, SHOWN THUS: -�• 2. THE CONSTRUCTION OF 4" AND 6 1, VCP (OR PVC) SEWER SERVICE LATERALS., Gi \\ SHOWN THUS: i \ 3. THE CONSTRUCTION OF 8" VCP (OR PVC) SEEP, MAIN CLEAN -OUT, SHOWN MHUS: 0C.0• S -3 4. THE CONSTRUCTION OF PCC SEWER MANHOLE SHOWN THUS ^ i S -1.1 D� 5. THE CONSTRUCTION OF S'T'ANDARD PIPE BEDDING S -4.1 i x\ 6. THE CONSTRUCTION OF SPECIAL PIPE BEDDING, WHERE REQUIRED Z 9 7. THE CONSTRUCTION OF TRENCH RESURFACING G -24.1 A U J \ - FOR THE CONSTRUCTION OF A d% L F3 L V a SPECIAL PROVIONS cente r- sw 1 0 4 Nw -rl a tJ� 1. ALL SEWER MAINS, SEWER SERVICE LATERALS, AND 'MANHOLE STRUCTURES SHALL BE AIR PRESSURE TESTED IN tl� THE PRESENCE OF THE ENGINEER.. v I J 2. EONNECTION OF SEWER SERVICE LATERALS DIRECTLY INTO MANHOLES WILL NOT BE PERMITTED, M a 3._ THE LOCATION, SLo7PE, AND ELEVATIONS OF SEWER SERVICE LATERALS SHALL BE AS SHOWN ON THESE PLANS. ar TOwoper�'y C3oundaYL� � In 4. CONTRACTOR SHALT NOTIFY THE ENCINITAS SANITARY DISTRICT, Q PHONE 753 -6639, NOT LESS THAN 48 HOURS I IY i - - IN ADVANCE OF STARTING WORK TO ARRANGE FOR PROJECT INSPECTION. 0 5. CONTRACTOR ; SMALL GUARANTEE ALT ,'WORK DONE UNDER THIS CONTRACT FOR A PERIOD OF ONE (1 � YEAR FROM AND W D ENCINITAS BLVD and SWEET AL LANE AFTER THE DATE OF ACCEPTA OF THE WORK BY THE OWNER, AND SHALL REPAIR OR REPLACE ANY OR ALL SUCH I � WORK, TOGETHER WITH ANY OTHER WORK--WHICH MAY BE DISPLACED, DAMAGED, OR DESTROYED IN SO DOING, THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND /OR MATERIALS WITHIN THE ONE YEAR PERIOD FROM DATE OF ACCEP- W Core TANCE, WITH NO COST TO THE OWNER; ORDINARY WEAR AND TEAR. EXCEPTED. 4. Sec 14-� for 6. CONTRACTOR SHALL OBTAIN THE REQUIRED PERMIT FROM THE COUNTY DE PA RTMENT OF TRANSPORTATION FOR ANY 50Ut6 line Isw a , Sec. \4 WORK WITHIN COUNTY RIGHT -OF -WAY. ST. ,JOHN CATHOLIC CHURCH NEW PARISH FACILITIES 7 W HELP OF T1�E ENGINEER, CONTRACTOR SHALL PROVIDE ALL NECESSARY DATA FOR THE PREPARATION OF " THE . _ AS BUILT ., DI:AWINGS PRIOR TO FINAL ACCEPTANCE OF THE WORK. RE M /` P 8. CONTRACTOR SHALL'OBTAIN "THE REQUIRED EXCAVATION PERMIT FROM THE STATE DIVISION OF INDUSTRIAL H SAFETY BEFORE STARTING ANY EXCAVATION, AND SHALL ADHERE TO ALL PROVISIONS OF THE STATE CONSTRUCTION I" zoo, + Et1Cif11tSS, California SAFETY ORDERS. 9. CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OF ALL [UNDERGROUND UTILITIES IN THE IMMEDIATE VICINITY OF THE WORK BEFORE STARTING ANY EXCAVATION. CONTRACTOR SHALL NOTIFY THE FOLLOWING AGEN- CIES OF THE PROPOSED WORK: SAN DIEGO GAS AND ELECTRIC PACIFIC BELL TELEPHONE CALL UNDERGROUND ENCINITAS SANITARY DISTRICT ENCINITAS SANITARY DISTRICT SERVICE ALERT - SAN DIEGUITO WATER DISTRICT 1 -800- 422 -4133 CABLE TELEVISION 10. ALL OPERATIONS IN CONNECTION WITH THIS WORK, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE, OR RUNNING OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT, OR ANY OTHER ASSOCIATED EQUIPMENT, SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 am AND 6 °00 pm EACH DAY, MONDAY THROUGH SATURDAY. EXCEPT IN CASES OF EMERGENCY OR PUBLIC SAFETY NO WORK OR WORK RELATED ACTIVITY SHALL BE CONDUCTED ON SUNDAYS OR NATIONAL HOLIDAYS. �clera.l L en th L Q SEINER LAT ERAL TA 3LE o Sewer Makti c leV. -To -0 ai cur b nvert prop ewer at Inv. peplh �S . below Curb, B Sewer Streefi Main - Elev. Top of Cat2ral at PROJECT . , �. o Sewer Iy1.seY`t Curb - C -lo�n� �inC t_engt�n, �P-%Aq � en d) L_ �- Si Sta kion Side Main to Invert Rboue L.at . Slope, 5 L L Cn arc q r�liq 1 nu 3 \0 1 - \1.55 I +24 4" 294 14 0,b( 302.c)(o 'D,o0 °l0 25' Z9�,85 5.1 seguesa p o -° - �'Auvt�t y CC1n 1 Q M O \k -� 3321 2 +45. - 12 4` Z9G,44 0,12 305•30 20.00 % Z4' 3ot,o) G 313 0 12��4,Z3 3� �1 4" 305,24 0, 6� °/ ' e. � a% e ri a I o e, 1 �, 3 314. be Z.0 0 22 30 0,54 6.1 l b a tad o - F ®� - Fto Line P a� � o - . W ® 14 5 tOS Cc>" 308.38 0,85 316.`01 2.0010 25 50913 °�•1 a �' `' ref t rF s h9� L. O 15- *-33.23 (,+4 4" 309.50 0-6(o 318.44 2.00 25' 3�1.IG &S B I LT eh � S a n� >-e dr. a, h j` , . ^�, I4 + t5.23 5 + 1 3 0.5` .�` - 31 `3.00 � x,00 °�® �' �` _;� � 1. �5 , � F z �� e oalred b w 4/5/ PRIVATE CONTRACT M reaw ed vN O 1 R LATERAL DEJAtL V I C I N I T `i MAP I W Flo. 28747 T� P. No se. e PERMITS SHEET COUNTY OF SAN DIEGO 4 O X �, ��3'�/'9U * ( 1 COAS - SAL 1 DEPARTMENT OF PUBLIC WORKS SHEETS 1 NO ScaIG RICE 23 � s� CIVIC (See �. a te.ral Talole� PERMIT NO. (o -84._ :3 Tn FOF � / " RUS E PERMIT NO. P 83- 0-5e> TITLE SHEET TENTATIVE MAP NO. PL ANS FOM THE CONST 9,U CTI O N - Or 9 - - -_ S E \N E R M -4� - _ - -- `' SA fl p 1 eG It ITO WATER D E NC 1 N TAS SAN.I Tp,�Y D IST 12JC T COUNTY APPROVED CHANGES BENCH MARK _ - CALIFORNIA COORDINATE INDEX 31 - I No. Description Approved by Date Co 8 3 1 12 f ceded .t#� +E Tai t►u C� � DESCRIPTION: brass Cap in Caun _- - -- Approved R.J.Massman E I�} `w `t' Engineer of work: Q �•�" \"1�� ��YIe�I� Nelk DIRECTOR OF PUBLIC WORKS Z Mark Schneider- Gen. Ma a r t Q3 e4 ' c rra�f•ia'" Tr B y : % to n q� D ate- _ LOCATION: - Irt�erSeCttOr1 - E.rc(ri►tas eye R.C.E. 213 cc o �- &u eeman or,- Go*Go.25 q,,5.455_(& W z RECORD FROM: C = Z Stan Urban - Constr. Coorcdlnator Date Jack Y. k uloota - Dist. En�r. - RUE 1005(a DCI et Grading ELEVATION: • 4 DATUM: U . C. � G.S � O Date Permit No. Z = W Ch. LSD 91 FILE N0; I I r rr -I r1 NoText NoText NoText