Loading...
2003-1456 G r G- � ' ENGINEERING SERVICES DEPARTMENT Capital Improvement Projects District Support Services Field Operations Sand Rep leni shment/Stormwater Compliance Subdivision Engineering Traffic Engineering August 19, 2005 Attn: Bank of America 1340 Encinitas Boulevard Encinitas, CA 92024 RE: Eric Murphy 631 3' Street APN 258- 165 -13 Grading Permit 1456 -GI Final release of security — 25% Permit 1456 -GI authorized earthwork, private drainage improvements, and erosion control, all as necessary to build described project. Final, acceptance, and warranty inspections have all been completed to the satisfaction of the Field Operations Division. Therefore, release of the remainder of the security deposit is merited. The following Certificate of Deposit Account has been cancelled by the Financial Services Manager and is hereby released for payment to the depositor. ___- .account .# 11824 -55407 in the - amount of $4,17S.50— - - -i -- - - — The document originals are enclosed. Should you have any questions or concerns, please contact Debra Geishart at (760) 633 -2779 or in writing, attention the Engineering Department. Sincerely, Debra Geishart )inan�ce ach Engineering Technician Manager Subdivision Engineering Financial Services CC: Jay Lembach, Finance Manager Eric Murphy Debra Geishart File Enc. Technical Field Services, Inc. � AS- GRADED GEOTECHNICAL REPORT, ELM DEVELOPMENT, 631 THIRD STREET, ENCINITAS, CALIFORNIA 92024 PREPARED FOR: Mr. Eric L. Murphy 396 North Coast Highway 101 Encinitas, California 92024 PREPARED BY: Technical Field Services, Inc. 1944 Kellog Avenue, Suite 103 Carlsbad, California 92008 April 16, 2004 Project No. 3707 1944 Kellog Avenue, Suite 103 • Carlsbad, Ca. 92008 • (760) 434.2617 Technical Field Services, Inc, �- 1 - April 16, 2004 Project No. 3707 Mr. Eric L. Murphy 396 North Coast Highway 101 Encinitas, California 92024 Subject: As- Graded Report, Building Pad, 631 Third Street, Encinitas, California Dear Mr. Murphy: Transmitted herwith is our As- Graded Geotechnical Report for the subject project, dated April 16, 2004. The project is being constructed to facilitate a new building. The observation and testing services as authorized by you includes the grading of the building pad. This report presents a summary of the grading operations for the building pad and the results of our field and laboratory tests. We appreciate the opportunity to be of service and look forward to continued involvement with your project. Should you have questions, please contact the undersigned. Respectfully submitted, Technical Field a ices, In V? HLR // q .00 Christopher ow `� p o. C 62262 evin Rooney Principal Engineer o o Exp: 6/2US � Staff Engineer CP/kr Distribution: (2)Address of CA1.1F� 1944 Kellog Avenue, Suite 103 • Carlsbad, Ca. 92008 • (760) 434.2617 ELM Building April 16, 2004 631 Third Street, Encinitas Project No. 3707 TABLE OF CONTENTS Page 1. INTRODUCTION .................................................................................... ............................... 1 2. SITE DESCRIPTION ............................................................................... ............................... 1 3. SUMMARY OF EARTHWORK OPERATIONS .................................... ............................... 1 4. FIELD AND LABORATORY TESTING ................................................. ............................... 1 5. CONCLUSIONS AND RECOMMENDATIONS .................................... ............................... 2 6. LIMITATIONS ........................................................................................... ..............................2 7. SELECTED REFERENCES .................................................................... ............................... 3 Illustrations Figure 1 — Field Density Test Location Map Tables Table 1 — Summary of Field Density Tests for Project No. 3707, Compacted Fill Table 2 — Maximum Density Test Results ELM BW&W As Gmded ELM Building April 16, 2004 631 Third Street, Encinitas Project No. 3707 1. INTRODUCTION In response to your request and authorization, we have provided geotechnical observation and test- ing services during the building pad grading operations for the project. The purposes of our services were to observe, document and test the materials used by the contractor, to construct the subject building pad. We performed field and laboratory tests of representative material samples to evaluate relative compaction of the fill placed at the site and to characterize the soil. Our findings and conclusions are presented herein. 2. SITE DESCRIPTION The subject site is located at 631 Third Street, within the City of Encinitas, in San Diego County. The site is bound by Third Street to the West, and private properties to the North and South, and an access alley to the East. Prior to grading, the site was gently sloping at an approximate grade of 5:1, with drainage to- wards the east. 3. SUMMARY OF EARTHWORK OPERATIONS Grading operations at the site commenced on March 26, 2004, and were completed on April 6, 2004. Our field technicians were generally on site full -time during the grading operation. In preparation for the placement of fill, the existing ground surface was over - excavated to 4 -1/2 feet in depth to remove loose soils, root and other deleterious materials from within the building pad area to a distance of approximately five feet outside the building limits. The excavated mate- rial was screened of debris and cleaned of root matter, and was moisture conditioned and compacted to at least 90 percent relative compaction. The imported material was moisture condi- tioned and mixed as it was laid in place with a loader /excavator. Lift thickness was kept to eight inches or less, and was compacted under several passes of the equipment tracks for each lift placed. The total fill depth is approximately one foot. The contractor used one Komatsu custom track driven excavator and one water truck to prepare the site and to perform the earthwork op- erations. 4. FIELD AND LABORATORY TESTING Field density tests were performed by our technicians during the site grading operation in general accordance with ASTM D1556 -90 (Sand Cone Method). The results of field density tests are presented in Table 1. The approximate locations of the field density tests are shown on Figure 1, Field Density Test Location Map. The specified relative compaction was 90 percent for compacted fill placed within building limits and to five feet outside building lines. Laboratory tests were performed on two representative samples of the fill materials to evaluate maximum dry density and optimum moisture content. The maximum dry density and optimum moisture content tests were performed in general accordance with ASTM D1557 -91, and the re- sults are presented in Table 2. 3707 EL Murphy Encinitas as- graded ELM Building April 16, 2004 631 Third Street, Encinitas Project No. 3707 5. CONCLUSIONS AND RECOMMENDATIONS Based on our observations and the results of our field and laboratory tests, it is our opinion that the grading operations were performed in general accordance with the current standard of prac- tice, and the Standard Specifications for Public Works Construction (1997 edition) including the Regional Supplement Amendments. Our opinion is relevant to the characteristics, relative com- paction and general locality of the fill materials. The certification of grades was the responsibility of others. 6. LIMITATIONS The geotechnical services outlined in this report have been conducted in accordance with current practice and the standard of care exercised by geotechnical consultants performing similar tasks in this area. No other warranty, expressed or implied, is made regarding the observations and conclusions expressed in this report. The reported test results represent the relative compaction and moisture content at the locations tested. It is important to note that the precision of field density tests and the maximum dry den- sity tests is not exact and variations should be expected. The reported locations, depths and elevations of the density tests are estimated based on correlations with the site plans. Further ac- curacy is not implied. 3707 EL Murphy Erwir iros as- graded 2 ELM Building April 16, 2004 631 Third Street, Encinitas Project No. 3707 7. SELECTED REFERENCES American Public Works Association, 1997, "Greenbook" Standard Specifications for Public Works Construction. City of San Diego, 1997, Supplement Amendments to the Standard Specifications for Public Works Construction, San Diego, Document No. 769818, dated February 2. Uniform Building Code, 1994, Volume 2, Structural Engineering Design Provisions. 3707 EL Murphy Endniw a Sn W 3 ELM Building April 16, 2004 631 Third Street, Encinitas Project No. 3707 Table 1— Field Density Test Results Test # Location Dry Density Moisture % Compaction % 1 NW pad -3' 128.5 7.8 98 2 NE pad -3' 124.7 9.9 95 3 NW pad -1' 123.6 7.8 94 4 NE pad -1' 120.8 8.5 92 5 SW pad -3' 128.9 10.0 98 6 SE pad —3' 120.2 8.2 92 7 SE pad —1' 125.7 8.8 96 8 RT on #10 SW pad —1' 113.4 9.7 87 9 SW pad surface 118.1 11.9 90 10 Re -test #8 120.6 8.6 92 11 East pad surface 126.3 9.6 96 12 West pad suface 127.4 7.6 97 Table 2 — Maximum Density Test Results Material Maximum Optimum Type No. Description Dry Density Moisture Content (pcf) ( %) 1 Fine brown silty Sand 131.0 8.2 2 Medium Brown silty Sand 128.5 9.0 3707 ELM Building As- graded ,� NOV - 19 - 03 WED 02:31 PM ECSCandE INC FAX:619 258 7962 1�'1 MFNTERPRISES PROJECT NO. 03- 1147B7(1) INTRODUCTION This is to present the findings and conclusions of a soil investigation for a proposed two -story office and residential building to be located on the east side o' 3rd Street, in the City of Encinitas, California. The objectives of the investigation were to evaluate the existing soils conditions and provide recommendations for the proposed construction. In order to accomplish these objectives, three (3) exploratory borings were drilled to a maximum depth of 5.0 feet; undisturbed and loose bag samples were obtained, an:i laboratory; tea s were performed. SITE DESCRIPTION AM PROPOSED CONSTRUCTION The subject sitc_: is located on the east side of 3rd Street, in the City of x ;nciriit.as, California. =t is presently occupied with a single -story home that will be demolished- The property slopes moderately to the southeast. Site boundaries include ?zd St=reet to the west, an all.c:y to the east, an office building to the south and a residential parcel to the north. Vegetation consisted of a few trees, shrubs and grass. I.t is our understanding that the propose construct will include a two - story, wood- framed, office and residential buildi_nc. The structure will be f_ouncled on coil tirluol:s footings with a slab - on - grade .`_loor. FIELD INVESTIGATION On November 3, 2..003, Lhree (3) exploratory borings were drilled to a mo.ximum depth of 6.0 feet with a 1':and auger. The aperoximate location:; of t }l e. bori ngs arc shown or. -he attached Plate 1 �0. 1, entitled "Location of Cxp? Crater;; Borings". A continuous log of the soils c;nc_ountered wus recorded at the time of ex ;ava _lon and is shown on Plate No. % enti tl.ec. "Sumrlar • Sheep_" . The soils were vi.sual.ly and ' Eexr_ura.l.l y c_assified accoidi.nq to the filr identi,fical - ion procedures set forLh on the atta� :shed Plate No. � entitled "Uni fort Sc_,- ". r. '1 %)�ssifi�u:;lc;�n (:hart NOV -.9 - 03 WED 02:32 FM ECSCandE INC rAX:6_9 26E 7902 `'A(iE ELY ENTERPRISES PROJFC.T NO, 03- 1147137(1) SMGPJ .DE CONDI 'IONS Topsoil and colluvz.um were encountered to a maximurr, depth of 4.5 feet below existing grade. These soils generally consisted of silty sand with a loose to medium dense consistency and low moisture: content. The colluvium was underlain by medium dense to dens: sandstone of the Terrace Deposits Formation. EXPANSIVE SOILS An expansion index test. was performed can a select samp-c of the colluvium to determine volumetric change c.haracter.istics with change in moisture content. An expansion index of 2 indicates a very low expansi.01 potcnti.al for the foundation soils. GROUNDWATER Groundwater was not encountered during the course of oi.r investigation. SLatic groundwater is anticipated at depths greater than 100 feet. We do not expect groundwater_ to affect the proposed development. GEOLOGIC HAZARDS A review of the available geological li era�ure pertaining to the site indicates the existence of t ^e Rose Canyon Fault Zcne approximately 4.0 Kin to the we:s Gro - shaking from this fault or one of the major ac7Jve faults in t:ne region is the most likely happening to affect. the site. with respect to this hazard, the site is comparable to o`- in the ge, . area. The proposed offic ;c and residential s :rucLure should be designed in accordance with seismic design requirements of the 1997 Uniform Building Code or the Structural Engineers Association of California using the .following seismic_ 6esign parameters: FA;EtAIV[E'Z'FR V ALUE CSC REF _66.66..... _.. Seismic Lone Factor, 7 j 0.40 - f able 16 - ..._ -- 6666... 6666_ __6666 . ,. Se ismic Source 13 "fable 16 -U - -6666 .. _. So il Profile `hype Sr, _ Table 16 - _ Near - Source hactar, Na 1.1 "fable 16 - Near- Source Factor, Nv j 1.3 `Cable 1 -T ._.........__ —__ __6666_... _6666 Seismic Coefficien Ca 0648 Ta ble 16 - Q R 16 Seisrnic Coefficient. C'v 0.83 Table - � 6666 _ - - - -.._ ___ ... .._ 6.666. _.. _..,. -_ a NUV - 19 -03 WED 02:32 PM ECSCandE INC FAX:6(9 258 7902 PAGE 4 ELM ENTERPRISES PROJECT NO. 03- 1147R7(l) Based on the absence of shallow groundwater and the consistency of the underlying 'Terrace Deposits Formation, it is our opinion that the potential, for liquefaction is very low. CONCZUSZONS AND RECOPOMMATIONS The following conclusions and recommendations are based upon the analysis of the data and information obtained from our soil investigation. This includes visual inspection; field investigation; laboratory testing and oul. general knowledge of the soils native to the site. The site is suitable for L..he pcQposed development provided the recommendat.icns set forth are implemented during construction. CRADZNG AND .EARTHWORK Site grading should begin witt_• clearing and grubbing, e.g. the removal of the existing structures, vegetation and deleterious materials. The subgrade soils extending to a depth of approximately 4.5 feet below existing grade and at least five (5) feet beyond proposed perimeter footings should be overexcavated, moisture conditioned within 3 percent over optimum and compacted to a minimum of 90 percent relative compaction. 1'he actual depth and extent of removal should be evaluated in the field at the time of excavation by a representative of this firm. Grading should be performed in ac.cor.d3nce with the .attached appendix A. FOUNDATION AND SLAB a. Continuous and spread footings are suitable for use on site. Continuous foat.in.crs shoo i d extend a m nimum of 18 inches for the two - story bu.tlding irlt() the properly ccmpa,�;ted fill soi..ls. These footings should be at least. .1.5 inches in ev_dth and re- inforced with four #4 steel. bars; two bars placed near the top of the footings and the other two ba rs placed near the bottom cf the footings. b. Concrete .f3.ct�r slabs should be a mir_irn -im of 4 inches trick. Reinforcement should consist of 43 bar-q placed at 18 inches on ccnt::r cacn way. :-)lab reinforcement srot:ld be placed w::.thin the middle thi..:d of t;hc :slab by suopo_t �r:g che steel. nn _hairs or concrete blocks "dobie:;" . The slab shc;uld be. underlain b; l: inches Of clean sand ovc -r a 10 - -mi ? vi.,queen - roist. re harrier. 4 NOV- -03 WED 02.32 PM ECSCandE INC PAX,E19 25c 7902 PAGE 5 F'1.M fNTERPRISES PROJECT N0. 03 -11 47137(1) The effect. of concrete shrinkage will result in cracks in virtually all concrete slabs. To reduce the exterit of shrinkage, the concrete should be placed at a maximum of 4 -inch slump. The minimum steel recommended is not intended to prevent shrinkage cracks. C. Where moisture sensitive floor coverings are anticipated over the slab, the 10-•mi.l plastic: moisture barrier should be underlain by a capillary break at least 2 Inches t:nic.k, consisting of coarse sand, gravel or crushed rock not exceeding 3/4 inch in size with no more than 5 percent passing the #200 siev d. An allowable soil bearing value of 2,000 pounds per square foot may be used for the design of continuous and spread footings at least 1.5 inches wide and founded a minimum of 18 inches into the properly compacted fill sails. This valu-2 may be increased by 650 psf percent for each additional foot of width or depth to a maximum val-ue of !,000 lb /ft2. e. Lateral resistance Lo horizontal movement may be provided by the soil passive pressure and the friction of concrete tc so 1. An allowable passive pressure of 250 pounds per square foot per foot of depth may be used. A coefficient o` friction of 0.35 is recommended. The soils passive pressure cis well as the bearing value may be i.ncr.easF�ci by 1/3 for wind and seismic loading. RETAINING WALLS Cantilevered retaining. walls with a level may be designed to resist an act :.ve equivalent fluid pressure of .35 pounds per cubic foot, while retaining walls wit.i a 2:1 ( horizontal to vertical) sloping backfill may be designed to resist an active equivalent fluid pressure of 45 pounds per cubic foot. This pressure is based on the backfi1J. soil being free dra_.n;.ng and non- exparisive. 5ackfili materials must be approved by the soils engineer p rior to lase. 5 AUV- 19 — U3 WED 02:33 PM ECSCandE INC FAX : E i 9 258 7902 F'AGE 6 ELM ENTERPRISES PROJECT N4. 03- 1147B7(1) Restrained walls, such as basement walls, that are not free to rotate should be designed-to resist an "at -rest" equivalent fluid pressure of 60 pounds per cubic foot. Restrained walls subject to uniform surcharge loads should be designed for an additional pressure of one -ha the anticipated surcharge. SETT.T.II�IENT Settlement of compacted fill soils is normal and shauld be anticipated. Because of the type and thickness of the f_- soi.ls under the proposed footings and the light building loads, settlement should be within acceptable 3Amit5 . UTILITY TRENCH EXCAVATION AND EAC W11,L Excavations for orl --site utiiit trenches may be made vertically for shallow depths acid must be Pither s!iored or sloped at 1H: 1v for depths greater than 4 feet. Utilities should be bedded and backfilled with clean sand or approved granular soil to a depth of at least one fool. over the pipe. This backfill should be uniformly watered and compacted to a firm condition for pipe support. The remainder of the backlill should be on -site soils or non - expansive impor soils, which should be placed '_n thin lifts, moisture conditioned and compacted to at least 90 9 z relative compaction. DRAINAGE Adequate measures ,should be undertaken to properly finish grade the site; after tine structure and other improvements are in place, such that the drainage water within the site and adjacent properties is directed away from the fok-.ndations, footings, floor slabs and the tops of slopes v`a surface swales and subsurface drains towards the natural drainage for this area. Proper surface and subsu drainage will be required to minimize the potential of water seeking the level of the bearing soils under the foundations, footings and f loor slabs ,a:rich may otherwise result i undermining and differential settlem of the structures and other impr ovements. . 6 1 NUV - 19 -03 WED 02 :23 PM ECSCandE INC t'AX:t;9 258 7902 PAGE 7 LLM. ENTERPRISESPROIECTN0 .0.3- 1147B7(1) .LIMITS OF INVESTIGATION The recommendations provided in this report pertain only to the site investigated and based upon the assumption that the soil conditions do noL deviate from those disclosed in the borings. If any variations or undesirable condit are encountered during construction, or if the proposed construction will significantly differ from that pianned at the pr.eser_t time, East County Soil. Consultation and Engineering, Inc, should be notified sa that supplemental, recommendations can be provided. Plates No. 1 through 3, Pages L--1 and t, -2, R.eferenc.es, and Appendix A are parts of this r.epert. Respectfully submitted, r " No. C 054071 ° m ! s� CMS. OF C AlV.�R M;; ac ou Saliou Dial' o RCE 54071 MSD /Md 7 ,vva -_y -uI 1rn uZ jj ?m iMandE INC =AX:E1 25G 1 )(12 PACE $ 4e I 1 i EAST COUNTY SOIL CONSULTATION & ENGINEERING, INC. 10925 HARIt Y Rp , SUrM 1, SANTEE, CA 92071 (619) 238.79()1 Max (619) 25R -7902 NOV -19 -03 WED 02;34 PM ECSCandE INC FAX:6 258 7902 PAGE 10 MAJOR DIVISIONS SYMBOL, DESCRIPTI GW WELL GRADED GRAVELS OR GRAVEL- SAND MIXTURES, LITTLE OR N O FINES GRAVELS - G';P — — — (MORE THAN 1/3 POORLY GRADED GRAVELS OR GRAVEL -SAND OF COARSE MIXTURES, LITTLE OR NO FINES FRACTION GM >N0. 4 SIEVE SILTY GRAVELS, GRAVEL-SAND-SILT MIXTURES COARSi� SIZE} GC CLAYEY GRAVELS, GRAVEL- SAND -CLAY MIXTURES GRAINED SOILS (MORE THAN'/s OF SOIL > S� NO. 200 SIEVE SIZE) WELL GRADED SANDS OR GRAVELLY SANDS, LITTLE OR N FNES SANDS SP - (MORE THAN V: POORLY GRADED SANDS OR GRAVELLY SANDS, OF COARSE __, LI TTLE OR N O FINES FRACTION SM NU, 4 SIEVE SILTY SANDS, SILT -SAND MIXTURES : SIZE) - $C CLAYEY SANDS, SAND -CLAY MIXTURES ML INORGANIC SILTS AN VERY FINE SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS & SILTS WITH SLIG PLASTICITY CLAYS CL INORGANIC CLAY OF LOW T MEDIUM LIQUID LIMIT PLASTICITY, GRAV£1,L,Y CLAYS, SANDY CLAYS, c 90 r..— SILTY CLAYS. LEAN CLAYS FINE GRAINED OL ` SAILS I ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW P (MORE THAN % OF SOIL < MH Y NO. 200 SIEVE 317F) INORGANIC SILTS, MICACEOUS OR DIATOMACZOVS SIL & FINE SANDY OR SILTY SOIL S_, ELASTIC SILTS CLAYS CIS NOR.GANIC CLAYS OF HIGH PLASTICITY, FAT LIQUID LIMIT 30 CLAYS Oil ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, O RGANIC SILTY CLAYS, ORGANIC SILTS IfIGHLY ORGANIC SOILS Pi PEAT AND OTHER HIGHLY ORGANIC SOILS CLASSIFICATION CHART (UNIFIED SOIL CLASSIFICATION SYSTEM) 7° _. r CI. RAIN S IFICATION RANGE OF G SIZES I ^w U.S. STANDARD GRAIN SIZE [N SIEVE SIZE MILLIMETERS BOULDERS _ V A bove 12 Inches Above 305 1 COBBLE 1 1 2 Inches To 3 Incites 303 To 76.2 1 w GRAVEL I �3 lncheS to N0 4 76.2 to 4.76 Coarse 3 Incites to' /. (nch 76.2 to 19.1 Finc _ 1 ?: In to Flo. 4 19 1 to 4.7 SAND I No. 4 to No 200 4.76 to 0.074 0 kk »Yc� Coarse Flo. a 10 No 10 4. ,6 E0 2.00 o I Medium No. 10 to No 40 ..00 to 0 420 r= t :��• 1 K „c� Finc Nu. 40 to No. 200 0.420 to 0.07, ? ° SI AND C LAY I B elo +v Nu. 2 G0 I Below 0.0 1 ° 1 :o to w so ao \ . n 30 )o 14C uc .v GRAIN SIZE CHART PLASTICTYY CHART Er15T COUNTY SOIL CONSULTATIOv 1 — - AND ENGINEERING, INC. ELM EN3:TNRPRISES PROJECT 10925 HARTLEY ROAD. SUITE "I" SANTEE, C ALIFO RN IA 920"1 I PROJEC N0. 03 -114737(l) f PLATE 210. 3 1. 1 / 19/03 U.S.C SOIL C L.kS SI FICATION NOV - :9 - 03 WED 02:34 PM ECSCandE INC FAX:619 256 7902 PAGE ELM F,NTF.RPRISES PROJECT NO. 03- 114787(1) PAGE L -1 LABORATORY TEST RESULTS MAXIMUM .DENSITY AND OP'T'IMUM MOISTURE TEST RESULTS The maximum dry densities and optimum moisture contents of the .fill materials as determined by ASTM D1557-91, Procedure A which uses 25 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4 inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a I0 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6 inch diameter 1,13.3 cubic foot compaction cylinder are presented as follows: OPTIMUM MAXIMUM MOISTURE SOIL TYPE./ DRY DENSTTY CONTENT PROCEDURE 17FSC:RIPTTON T_R/ CU. FT. % DRY WT. LOCATION 1/A BROWN, SILTY 131.0 8.2 13-105, V -4' FIN1:E- GRAINED SAND RESULTS OF EXPANSION NDEX TEST An expansion test in confin with ASTM D4829 was performed on a representative sample of on -site foundation soils to determine volumetric change characteristics with change in moisture content. The recorded expansion of the sample is presented as follows: INITIAL SATURATED INITIAL, DRY MOISTURE, MOISTURE DENSITY EVANSTON CONTENT% . _ CONTENT% LB_i F T. INDEX LOCATION 7.6 13.9 116.6 2 B -1 (u7 2 9 NOV 1.9 - 03 VIED 02;34 PM ECSCandE INC FAX,6'9 250 7902 PACE 12 F, I.M ENT LsRPRI.SF.S PROJEC T NO. 03 PAGE L - 2 LABORATORY TEST RESULTS RESULTS OF PARTICLE SI7_F. ANALYSIS U.S, Statndrd Pers:ent Passing Percent Passing Sieve Size B� l @ l A'- AA' B -2 @:0' (MT M D -422) 3 „ - 2 1/2" - - #4 - - #8 100 #i6 qq 100 #30 85 8-17 #60 34 3 #100 23 24 #200 20 18 - ..... SM t r� NOV -19 -03 WED 02;34 PM ECSCandE INC 4AX:619 253 7902 PANE 13 FGMENTERPRLSFS PROJECT NO. 03- 11=1717(1) REFERENCES 1. "1997 Edition, Uniform Building Code, volume 2, Structural Engineering and Design Provisions ". 2. "Maps of Known Active Fault gear- -Sou r.c;P Zones in California and Adjacent Portions of Nevada ", Page 0 -36, used with the 1997 Edition of the Uniform Building Code, Published by international Conference of Building Officials. 3. "Geologi.c Maas of the Northwestern ?art. of Sari Dip ga County, California, Plate No. 2, Geologic Maps of the Encinitas and Rancho Santa Fe 7.5' Quadrangles ", by Siang S. Tan and Michael P. Kennedy, 1996. 11 NuV -_9 -01 WED 02;35 PM R ECSCandE INC FAX;6 :9 258 7902 EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE. I SANTEE, CALIFORNIA 92071 (619) 258 -7901 APPENDIX A RECOMMENDED EARTHWORK SPECIFICATIONS 1. General Description The intent of these specifications is to obtain uniformity and adequate strength in filled ground so that the proposed strictures may be safely supported. The procedures include the clearing and preparation of the land to be filled, processing the fill soils, 'he spreading, and compaction of the filled areas to conform with the lines and grades as shown on the approved plans. The owner shall retain a Civil Engineer qualified in soil mechanics (herein referred to as engineer) to inspect and test earthwork in accordance with these specifications. The engineer shall advise the owner and grading contractor immediately if any unsatisfactory conditions are observed to exist and shall have the authority to reject the compacted filled ground until such time that corrective measures are taken, necessary to comply with the specifications. It shall be the sole responsibility of the grading contractor to achieve the specified degree of compaction: 2. Preparing Areas to be T=illed (a) All brush, vegetation and any biodegradable rc--use shall be removed or otherwise disposed of so as to leave the areas to be filled free of vegetation and debris. Any uncompacted filled ground or loose compressible natural ground shall be removed unless the report recommends otherwise. Any buried tanks or other structures shall be removed and the depression backftlled to the satisfaction of the engineer. (b) The natural ground which is determined to be sat sfactory for the support of the filled ground shall then be plowed or scarified to a depth of at least 12 inches 0 2 "). (c) After the natural ground has been prepared, it shall then be brought to the proper moisture content and compacted to not less than 90 percent ;'maximum dry density in accordance with AS'I'A D1557 -91. (d) Where tills arc made on slopes greater than 20 percent, horizontal benches shall be cut into the firm natural brMund. The initial bcnch at the toe of th-- till shall be at least 15 feet in width on firm undisturbed natural ground. The width of all succeedi;ig benches shall be at least 6 feet. NOV -19 - 03 WED 02:31 PM ECSCandE INC FAX :6',9 253 790'2 Ck FAST COUNTY SOIL CONSULTATION ANI) FNGINFERING, INC. 10925 HARTLEY ROAD, SUITE I. SAN TEF, CALIFORNIA 92071 (019) 258 - 7901 Fax 258 -7902 November 19, 2003 Eric Murphy r ELM Enterprises 396 North Coast H i,ghw7y 1.01 Enc:inz.tas, cali.fornia 92024 Subject: Limited Site Investigat_on proposed Two -Story Office and Re _ identiai Buildinq 631 :3' Street, APN 258- - 13 -�'0'- C:i.ty of Enc:i r:itas, Cali .�S nia Dear Mr. M urphy: In accordance with your request, we h1m7e performed a limited investigation of the soil conditions a': the subject si.te. The investigation was undertaken to provi.,;ia the sail P:ngineering crite.r,,i . fur site grading and recommena an aopropri.at_e Foundation system `or t�Ze proposed office and resic,e: tal building. Our investigation found that the site is underlain by topsoil and colluvi.um to a maximum depth of 4.5 feet below existing grade. Medium dens; to dense sandstone of tithe Terrace Dep,u__sit.s Formation was underlying the c:olluvium. It is oi:lr opinion that the proposcci development i s feasible provided t:he rec:omrttendations herein are implement;- during construction. Resouctfully tt_ed, mamaldau Saliou D ailo, t''. RC,F 5 � 0 71 ' NGINEERING SERVICES DEPARTMENT Cit1O� Encinitas Capital Improvement Projects District Support Services Field Operations Sand Rep lenishment /Stormwater Compliance Subdivision Engineering Traffic Engineering July 6, 2004 Attn: Bank of America 1340 Encinitas Boulevard Encinitas, CA 92024 RE: Eric Murphy 631 3 " Street APN 258 - 165 -13 Grading Permit 1456 -GI Final release of security — 75% Permit 1456- GI authorized earthwork, private drainage improvements, and erosion control, all as necessary to build described project. Final, acceptance, and warranty inspections have all been completed to the satisfaction of the Field Operations Division. Therefore, release of the remainder of the security deposit is merited. The following Certificate of Deposit Account has been cancelled by the Financial Services Manager and is hereby released for payment to the depositor. Account # 11824 -55520 in the amount of $12,535.50. The document originals are enclosed. Should you have any questions or concerns, please contact Debra Geishart at (760) 633 -2779 or in writing, attention the Engineering Department. Sinc rely, Masih Maher J' L bath Senior Civil Engineer ina ce Manager Subdivision Engineering Financial Services CC: Jay Lembach, Finance Manager Eric Murphy / E & E Properties Debra Geishart File TEL 760 -633 -2600 / FAX 760- 633 -2627 505 S. Vulcan Avenue, Encinitas, California 92024 -3633 TDD 760 -633 -2700 � recycled paper r EAST COUNTY SOIL CONSULTATION ` . AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE 44 SANTEE, CALIFORNIA 92071 (619) 258 -7901 Fax 258 -7902 Eric Murphy November_ 19, 2003 ELM Enterprises Project No. 03- 1147B7(1) 396 North Coast Highway 101 Encinitas, California 92024 Subject: Limited Site Investigation Proposed Two -Story office and Residential Building 631 3rd Street, APN 258- �-13 - 00 City of Encinitas, California Dear Mr. Murphy: In accordance with your request, we have performed a limited investigation of the soil conditions at the subject site. The investigation was undertaken to provide the soil engineering criteria for site grading and recommend an appropriate foundation system for the proposed office and resi dential building. Our investigation found that the site is underlain by topsoil and colluvium to a maximum depth of 4.5 f -let below existing grade. Medium dense to dense sandstone of the Terrace Deposits Formation was underlying the colluvium. It is our opinion that the proposed development is feasible provided the recommendations herein are implemented during construction. Respectfully submitted, Mamadou Saliou Diallo, P.E RCE 54071 1 { Y ELM ENTERPRISES PROJECT NO. 03- 1147B7(1) INTRODUCTION This is to present the findings and conclusions of a ,soil investigation for a proposed two -story office and residential building to be located on the east side of 3rd Street, in the City of Encinitas, California. The objectives of the investigation were to evaluate the existing soils conditions and provide recommendations for the proposed construction. in order to accomplish these objectives, three (3) exploratory borings were drilled to a maximum depth of 6.0 feet; undisturbed and loose bag samples were obtained, and laboratory tests were performed. SITE DESCRIPTION AND PROPOSED CONSTRUCTION The subject site is located on the east side of 3rd Street, in the City of Encinitas, California. It is presently occupied with a single -story home that will be demolished. The property slopes moderately to the southeast. Site boundaries include 3rd Street to the west, an alley to the east, an office building to the south and a residential parcel to the north. Vegetation consisted of a few trees, shrubs and grass. It is our understanding that the proposed construction will include a two - story, wood -- framed, office and residential building. The structure will be founded on continuous footings with a slab -on -grade floor. FIEID INVESTIGATION on November 3, 2003, three (3) exploratory borings were dr.il.le(_l to a maximum depth of 6.0 feet with a hand auger. The approximate locations of the borings are shown on the attached P.lat_e No. 1, entitled ",Location of Exploratory Borings ". A continuous loci of the soils encountered was recorded at the time of excavation and is shown on Plate No. 2 entitled "Summary Sheet ". The soils were visually and texturally classified according to the filed identification procedures set forth on the attached Plate No. 3 entitled "Uniform Soil Classification Chart ". 2 ELM ENTERPRISES PROJECT NO. 03-1147B7(l) SUBGRADE CONDITIONS Topsoil and colluvium were encountered to a maximum depth of 4.5 feet below existing grade. These soils generally consisted of silty sand with a loose to medium dense consistency and low moisture content. The colluvium was underlain by medium dense to dense sandstone of the Terrace Deposits Formation. EXPANSIVE SOILS An expansion index test was performed on a select sample of the colluvium to determine volumetric change characteristics with change in moisture content. An expansion index of 2 indi.cateS a very low expansion potential for the foundation soils. GROUNDWATER Groundwater was not encountered during the course of our investigation. Static groundwater is anticipated at depths greater than 100 feet. We do not expect groundwater to affect the proposed development. GEOLOGIC HAZARDS A review of the available geological literature pertaining to the site indicates the existence of the Rose Canyon fault ",one approximately 4.0 Km to the west. Ground shaking from this fault or one of the major active faults in the region is the most likely happening to affect the site. With respect to this hazard, the site is comparable to others in the general area. The proposed office and residential structure should be designed in accordance with seismic design requirements of the 1997 Uniform Building Code or the Structural Engineers Association of California using the following seismic design parameters: PARAMETER VALUE UBC REFERENCE Seismic Zone Factor, Z 0.40 Table 164 Seismic Source B Table 16-U Soil Profile Type SD Table 16 -J Near -Source Factor Na 1.1 Tablc 16 -S Near- Source Factor, Nv 1.3 Table 16-T Seismic Coefficient, Ca 0.49 Table 16- Seisrnic Coefficient, Cv 0.83 Table 16 -R _ _ ELM ENTERPRISES PROJECT NO. 03- 114787(1) Based on the absence of shallow groundwater and the consistency of the underlying Terrace Deposits Formation, it is our opinion that the potential for liquefaction is very low. CONCLUSZONS AND RECCMMNMTZONS The following conclusions and recommendations are based upon the analysis of the data and information obtained from our soil investigation. This includes visual inspection; field investigation; laboratory testing and our general knowledge of the soils native to the site. The site is suitable for the proposed development provided the recommendations set forth are implemented during construction. GRADING AND EARTHWORK Site grading should begin with clearing and grubbing, e the removal of the existing structures, vegetation and deleterious materials. The subgrade soils extending to a depth of approximately 4.5 feet below existing grade and at least five (5) feet beyond proposed perimeter footings should be overexcavat;ed, moisture conditioned within 3 percent over optimum and compacted to a minimum of 90 percent relative compaction. The actual depth and extent of removal should be evaluated in the field at the time of excavation by a representative of this firm. Grading should be performed in accordance with the attached appendix A. FOUNDATION AND SZAH a. Continuous and spread footings are suitable for use on sate. Continuous footings should extend a minimum of 18 inches for the two -story building into the properly compacted fill soils. These footings should be at least 15 inches in width and reinforced with four #4 steel bars; two bars placed near the top of the footings and the other two bars placed near the bottom of the footings. b. Concrete floor slabs should be a minimum of 4 inches thick. Reinforcement should consist of #3 bars placed at 18 inches on center each way. Slab reinforcement should be placed within the middle third of the slab by supporting the steel on chairs or concrete blocks "dobies ". The slab should be underlain by 2 inches of clean sand over a 10 -mil visqueen moisture barrier. 4 ELM ENTERPRISES PR OJECT NO. 03-1147B7(i) The effect of concrete shrinkage will result in cracks in virtually all concrete slabs. To reduce the extent of shrinkage, the concrete should be placed at a maximum of 4 -inch slump_ The minimum steel recommended is not intended to prevent shrinkage cracks. c. Where moisture sensitive floor coverings are anticipated over the slab, the 10 -mil plastic moisture barrier should be underlain by a capillary break at least 2 inches thick, consisting of coarse sand, gravel or crushed rock not exceeding 3/4 inch in size with no more than 5 percent passing the #200 sieve- d. An allowable soil bearing value of 2,000 pounds per square root may be used for the design of continuous and spread footings at least 15 inches wide and founded a minimum of 18 inches into the properly compacted fill soils. This value may be increased by 650 psf percent for each additional foot of width or depth to a maximum value of 4,000 lb /ft2. e. Lateral resistance to horizontal movement may be provided by the soil passive pressure and the friction of concrete to soil_ An allowable passive pressure of 250 pounds per square foot per foot of depth may be used. A coefficient of friction of 0.35 is recommended. The soils passive pressure as well as the bearing value may be increased by 1/3 for wind and seismic loading. RETAINING WALLS Cantilevered retaining walls with a level backfill may be designed to resist an active equivalent fluid pressure of 35 pounds per cubic foot, while retaining walls with a 2:1 (horizontal to vertical) sloping backfill may be designed to resist an active equivalent fluid pressure of 45 pounds per cubic foot. This pressure is based on the backfill soils being free draining and non - expansive. Backfill materials must be approved by the soils engineer prior to use. 5 ELM ENTERPRISES PROJECT NO. 03- 1147117(1) Restrained walls, such as basement walls, that are not free to - rotate should be designed to resist an "at- rest" equivalent fluid pressure of 60 pounds per cubic foot. Restrained walls subject: to uniform surcharge loads should be designed for an additional pressure of one -half the anticipated surcharge. SETTLEMENT Settlement of compacted fill soils is normal and should be anticipated. Because of the type and thickness of the fill soils under the proposed footings and the light building loads, settlement should be within acceptable limits. UTILITY TRENCH EXCAVATION AND BACKSILL Excavations for on -site utility trenches may be made vert.ic.�lly for shallow depths and must be either shored or sloped at 1H: lv for depths greater than 4 feet. Utilities should be bedded and backfilled with clean sand or approved granular soil to a depth of at least one foot over the pipe. This backfill should be uniformly watered and compacted to a firm condition for pipe support. The remainder of the backfill should be on -site soils or non- expan:::ive imported soils, which should be placed in thin lifts, moisture conditioned and compacted to at least 90 % relative compaction. DRAINAGE Adequate measures should be undertaken to properly finish grade the site after the structure and other improvements are in place, such that the drainage water within the site And adjacent properties is directed away from the foundations, footings, floor slabs and the tops of slopes via surface swales and subsurface drains towards the natural drainage for this area. Proper surface and subsurface drainage will be required to minimize the potent:ial of water seeking the level of the bearing soils under - the foundations, footings and floor slabs, which may otherwise result in undermining and differential settlement of the structures and other improvements. 6 EI. ENTERPRISES PROJECT NO. 03- 1147B7 {1) LIMITS OF ZNMSTZGATZON The recommendations provided in this report pertain only to the site investigated and based upon the assumption that the soil conditions do not deviate from those disclosed in the borings. If any variations or undesirable conditions are encountered during construction, or if the proposed construction will significantly differ from that planned at the present time, East County roil Consultation and Engineering, Inc. should be notified :3o that supplemental recommendations can be provided. Plates No. 1 through 3, Pages L -1 and L -2, References, and Appendix A are parts of this report. Respectfully submitted, No. CO54071 � s Q CMt Z. ` � I - Mamadou Saliou Diallo RCE 54071 MSD /md 7 /!rJ i FAST COUNTY SOIL CONSULTATION do ENGINEERING. INC. ` ; ;4 4 7 10923 HARTLEY RD_. SUITE I. SAKME. CA 92071 (619) 258 -7901 Fax (619) 251b?"2 47lOd o�!'f3'!- �°.►¢T�,�/il/G� ""' alb. / EI,M ENTERPRISES PROJECT NO. 03- 114787(1) PLATE NO. 2 SUMMARY SHEET NO. 1 BORING NO. 1 DEPTH SOIL DESCRIPTION X M Surface TOPSOIL dark brown, dry, loose, silty fine grained sand with rootlets 1.0' COLLUVIUM (Qal) brown, dry, loose, fine grained silty sand (SM) ., 12.2 5.2 2.5' 4.5' TERRACE DEPOSITS (4tl) tan, moist, medium dense to dense, fine grained silty sand (SM) 6.0' bottom of boring, no caving, no groundwater boring backfilled 11/3/03 BORING NO. 2 DEPTH SOIL DESCRIPTION Y M Surface TOP$om dark brown, dry, loose, silty fine grained sand with rootlets 1.0' cOLLUVIUM (Qal) brown, dry to moist, loose to medium dense, fine grained silty sand (SM) 4.0' TIZRRACE DEPOSITS (Qt:) tan, moist, medium dense to dense, fine grained silty sand (SM) 5.0' bottom of boring, no caving, no groundwater boring backfilled 11/3/03 -------------------------------------------------------------- BORING NO. 3 DEPTH SOIL DESCRIPTION y M Surface TOPSOIL Dark brown, dry, loose, si:'_y fine drained sand with rooti.nts 1.0' COLLUVIUM (Qal) brown, dry to moist, loose "_o medium dense, fine grained silty sand (SM) G 3.0' ,. ., 10.1.9 5.0 4.5' TERRACE DEPOSITS (Qtt) tan, moist, medium dense to dense, fine grained silty ;and (SM) 5.0' bottom of boring, no ca ring, no y-aundwar.cr boring backfilled 13./3/03 --------------------------------------- I MAJOR DIVISIONS SYMBOL LL�.3l.ii.. 11V1\ GW Why GRADED GRAVELS OR GRAVEL- SAND ` MIXTURES. Lfl I'LE OR NO FINES GRAVELS GP POORLY GRADED GRAVELS OR GRAVEL -SAND (MM THAN E % MIXTURES. LITTLE OR NO PINES OF COARS FRACTION GM SLTY GRAVELS, GRAVEL -SAND 91LT MIXTURES >-M. 4 SIEVE COARSE SIZE) GC CLAYEY GRAVELS. GRAVEL -SAND -CLAY MDCfURES G RAINED SOILS (MORE THAN Vs OF SOIL > Sw 140. 200 SIEVE 51ZE} WELL GRADED SANDS OR GRAVELLY SANDS, LITTLE OR NO FINES - SANDS SP POORLY GRADED SANDS OR GRAVELLY SANDS. (MORE THAN 'A UTTLEOR NO FM _ OF COAASE ION SM < NO.1 SIEVE SILTY SANDS. SILT-SAND MIXTURES s� SC CLAYEY SANDS, SAND -CLAY MIXTURES ML 6oRGAN RTS AND VERY FINF SANDS, ROCK FLOUR SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS & SILTS wITH WOW PLASTICITY CLAYS CL INORGANIC CLAYS OF LOW TO MEDIUM PL*SMfTY GRAVELLY LIQUID UMTf • CLAYS, SANDY CLAYS. SILTY CLAYS. LEAN CLAYS < SO FINE GRAINED OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF SOILS LOW PLUTXTM (MORE THAN 'A OF SOIL < MCI N0.200 SIEVE S217 INORGANIC SILTS. MICACEOUS OR DIATOMACEOUS SILTS & FINE SANDY OR SILTY SORB. ELASTIC SILTS CLAYS CH INORGANIC CLAYS OF HIGH PLASTICtf Y. FAT LIQU D LIMTT CLAYS OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY. ORGANIC SILTY CLA YS ORGANIC SILTS HIGHLY ORGANIC SOILS Pt PEAT AND OTHER HIGHLY ORGANIC SOILS CLASSIFICATION CHART (UNIFIED SOIL CLASSIFICATION SYSTEM) I . L CLASSIFICATION OF GR.tIV I 1 w U.S. STANDAJW GF-UN SM IN I I I SIEVESIZE munwETERS BOULDERS AOVrc Ms l2 htcha Abore 305 � , I r i'l G ' I COBBLTMS 12 W To 3 locftes 103 To 76.3 = 'O ( I ( 4 CRAWL 3 Inches to ro. 4 76Z to 4. Come 3 Incites to V. hldt 76-21619.1 w I Fine Y. Inch to No. 4 19 1 to 4.76 SAND Na. 4 10 No. 200 0 .76 to 0.074 ° I ( ! ' I ( BC" No. # to No. 10 4.76 to 2.00 1 Meddiu�m No. Io to Na 40 2.00 to 0.420 Fine No. 40 to N0. 200 0.420 to 0.074 40 To w w .ao SILT AND CLAY Below Nu. 200 Below 0.074 ,r ".L . ; GRAIN SIZE CHART PLASTICITY CHARRT EAST COUNTY SOIL CONSULTATIO AND ENGINEERING, INC. ENTERPR ISES PROJECT 10925 HARTLEY ROAD, SUITE "I" ECT N0. 03- 11478 (1) SANTEE, CALIFORNIA rMI 3 11/19/03 PLATE N0. U.S,C.S. SOIL CLASSIFICATION ELM ENTERPRISES PROJECT NO. 03-1147B7(i) PAGE L - 1 LABORATORY TEST RESULTS MAXIMUM DENSITY AND OPTIMUM MOISTURE TEST RESULTS The maximum dry densities and optimum moisture contents of the fill materials as determined by ASTM D1557 -91, Procedure A which uses 25 blows of a 10 pound slide hammer failing from a height of 18 inches on each of 5 equal layers in a 4 inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6 inch diameter 1113.3 cubic foot compaction cylin&-r are presented as follows: OPTIMUM MAXIMUM MOISTURE SOIL TYPE/ DRY DENSITY CONTENT PROCEDURE DESCRIPTION LB/ CU. FT. % DRY WT. L OCA "1 _ION I/A BROWN, SILTY 131.0 8.2 B -1 (cr�7 VA' FINE - GRAINED SAND RESULTS OF EXPANSION INDEX TEST An expansion test in conformance with ASTM D4829 was performed on a representative sample of on -site foundation soils to determine volumetric change characteristics with change in moisture content. The recorded expansion of the sample is presented as follows- INITIAL SATURATED INITIAL DRY MOISTURE MOISTURE DENSITY EXPANSION CONTENT" /o CONTENT% LB. /CU. FT INDEX _ LOCATIO 7.6 13.9 116.6 2 B -I (@aT 9 ELM ENTERPRISF.S PROJECT NO. 03-114 PAGE L -2 LABORATORY TEST RESULTS RESULTS OF PARTICLE SIZE ANALYSIS ertat Pnssirig Percent Passing = `P x =" -. - - °I3-2 Q 4.ft' _ '��� ��::. •. & 1 1.0 - 4.0 i s D-.K — 3" _ - 2 ,> _ - l „ 112" 3 /S" - #4 _ #8 l00 #1b 99 100 #30 85 87 #b0 34 35 #100 23 24 #200 20 IS USCS SM SM' - 10 ELM ENTERPRISES PROJECT NO. 03- 114787(1) REFERENCES } 1. 11 1997 Edition, Uniform Building Code, Volume 2, Structural Engineering and Design provisions". 2. "Maps of Known Active Fault Near- Source Zones in California and Adjacent Portions of Nevada ", Page 0 -36, used with the 1997 Edition of the Uniform Building Code, Published by International Conference of Building Officials. 3. "Geologic Maps of the Northwestern Part of San Diego County, California, Plate No. 2, Geologic Maps of the Encinitas and Rancho Santa Fe 7.5' Quadrangles ", by Siang S. Tan and Michael P, Kennedy, 1996. I1 EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE I SANTEE, CALIFORNIA 92071 (619) 258 -7901 APPENDIX A RECOMMENDED EARTHWORK SPECIFICATIONS 1. General Description The intent of these specifications is to obtain uniformity and adequate strength in filled ground so that the proposed aructures may be safely supported. The procedures include the clearing and preparation of the land to be filled, processing the fill soils, the spreading, and compaction of the filled areas to conform with the lines and grades as shown on the approved plans. The owner shall retain a Civil Engineer qualified in soil mechanics (herein referred to as engineer) to inspect and test earthwork in accordance with these specifications. The engineer shall advise the owner and grading contractor immediately if any unsatisfactory conditions are observed to exist and shall have the authority to reject the compacted filled ground until such time that corrective measures are taken, necessary to comply with the specifications. It shall be the sole responsibility of the grading contractor to'achieve the specified degree of compaction: 2. Preparing Areas to be Filled (a) All brush, vegetation and any biodegradable refuse shall be removed or otherwise disposed of so as to leave the areas to be filled fee of vegetation and debris. Any uncompacted filled ground or loose compressible natural ground shall be removed unless the report recommends otherwise. Any buried tanks or other structures shall be removed and the depression backfilled to the satisfaction of the engineer. (b) The natural ground which is determined to be satisfactory for the support of the filled ground shall then be plowed or scarified to a depth of at least 12 inches (12 "). (c) After the natural ground has been prepared, it shall then be brought to the proper moisture. content and compacted to not less than 90 percent of maximum dry density in accordance with ASTM D1557 -91. (d) Where fills are made on slopes greater than 20 percent, horizontal benches shall bt: cut into the f nn natural ground. The initial bench at the toe of the fill shall be at least 15 feet in width on firm undisturbed natural ground. The width of all succeeding benches shall be at least 6 feet. APPENDIX A 2 3. Fill Materials All material shall be approved by the engineer and shall consist of materials free from vegetable matter, and other lumps greater than 6 mchcs in diameter. lf, during grading operations, soils are found which were not encountered and tested in the preliminary investigation, tests on these soils shall be performed to determine their physical characteristics. Any special treatment recommended in the PrelUMEY or subsequent soils reports not covered herein shall become an Addendum to these specifications. 4. Placing and Compacting Fill Materials (a) When the moisture content of the fill material is below that specified, water. shall be added until the moisture content is tear optimum to assure uniform mixing and effective compaction. (b) When the moisture content of the fill materials is above that specified, the fill matrriaI shall be aerated by blading and scarifying or other satisfactory methods until the moisture content is near optimum as specified. (c) After processing, the suitable fill materials shall be placed in layers which, when compacted, shall not exceed six inches (6 "). Each layer shall be spread evenly and shall be thoroughly mixed during the spreading insure uniformity of materials and moisture in each layer. (d) After each layer has been placed, mixed and spread evenly, it shall be thoroughly compacted to not less than the density set forth in paragraph 2 (c) above. Compaction shall be accomplished with approval types of compaction equipment. Rolling shall be accomplished while the fill material is at the specified moisture content. In place density tests shall be performed in accordance with ASTM D 1556 -90. (e) The surfaces of the fill slopes shall be compacted by means of shcepsfoot rollers or other suitable equipment. Compacting operations shall be continued until the slopes arc stable and until there is no appreciable amount of loose soil on the slopes. 5. Inspection Sufficient inspection by our firm or the Soil's Engineer of record and/or his /her represenUtt►ve shall be maintained during the filling and compacting operations so that he /she can verify that the fill. was constructed in accordance with the accepted specifications. 6. Seasonal Limits No fill material shall be placed, spread, or rolled if weather conditions increase the moisture content above permissible limits. When the work is interrupted by rain, fill operations shall not be resumed until the moisture content and density of fill are as previously specified. All recommendations presented in the attached report are a part of these specifications. 2 Rtc p Uu 1REP! 7 DOCUMENT flu t,. ffliWTV GREGORY LJ EM1. IF TI Hi 5 -"UUM F."E. 1-N 'T-60 Cffl R FCA I Recording Requested by: City Engineer When Recorded mail To: City Clerk City of Encinitas 505 south Vulcan Avenue Encinitas, CA ..92024 SPACE ABOVE FOR RECORDER'S USE COVENANT REGARDING REAL PROPERTY WAIVER OF PROTEST TO ASSESSMENTS Assessor's Parcel Work Order 1456-G Number: 258-1-65-13 Project 02-196 DR/CDP A. E and E Transportation/ Inc, a California Corporation ("OWNER" hereinafter) is the owner of real property ("PROPERTY" hereinafter) and which is legally described as follows: See Attachment "All which is attached hereto and made a part hereof. B. In consideration of 02-196 DR/CDP, OWNER hereby covenants and agrees for the benefit of CITY, to do the following: No protest shall be made by the owners to any proceedings for the installation or acquisition of street improvements, including undergrounding of utility lines, under any special assessment 1911 or the Municipal Improvement Act of 1913, or any - other applicable state or local law, and whether processed by the City of Encinitas or any other governmental entity having jurisdiction in the matter and for the purposes of determining property owners support for same. C. This Covenant shall run with the land and be binding upon and inure to the benefit of the future owners, successors, heirs, personal encumbrancers, f the representatives, transferees and assigns 0 respective parties. D. OWNER agrees that OWNER's duties and obligations under this Covenant are a lien upon the PROPERTY. Upon notice and opportunity to respond, CITY may add to the property tax bill of the PROPERTY any past due financial obligation owing to CITY by way of this Covenant. E. If either party is required to incurs costs to enforce the provisions of this Covenant, the prevailing party shall be entitled to full reimbursement of all costs, including reasonable attorney's fees, from the other party. F. Failure of the OWNER to comply with the terms of this Covenant shall constitute consent to the filing by CITY of a Notice of Violation of Covenant. G. Upon OWNER's satisfaction of OWNER's duties and obligations contained herein, OWNER may request and CITY shall execute a "Satisfaction of Covenant ". H. By action of the City Council, CITY may assign to a person or persons impacted by the performance of this Covenant, the right to enforce this Covenant against OWNER. AC PTED AGREED: OWNER P P1 )so I� Eric Murphy, Print Title E & E Transport ion, Inc. b k Date (Notarization of OWNER signature is attached) CITY F CIN Dated , /c3�d� by Peter Cota- Robles, (Notarization not required) Director of Engineering Services Legal Description of Real Property 631 Third Street APN 258 - 165 -13 The real property situated in the City of Encinitas, County of San Diego, State of California, described as: Lot 12, Block 19 according to Map thereof No. 148, filed in the office of the County Recorder of San Diego County on June 12, 1883. CALIr ORI:IA ALL•PunpoSE ACKNOVILEDGMENT State of j2 4 ` 1 k` County of A On of before me, D" Mo Tue a oaks, p.o., im Wo. Mowry PAW) . perso ly appeared •' IN o' &,q4r�) : � ersonally known to (rte — OR — O proved to me on the basis of satisfactory evidence to be the persons) whose name(494re subscribed to the within instrument and acknowledged to me th4 hetthey executed the ' OFFICIAL SEAL er/their authorize 'capacity(ies), and that by ARTHUR P ARQUILLA hi er the' Ir signatures) on the instrument the person(s), NOTARY PUBLIC- CALIFORNIA or the entity upon behalf of which the person(s) acted, COMM. NO. 1334102 ;i SAN DIEGO COUNTY executed the instrument. itAl' 000 EXP. JAN.7, 2006 ! WITN* my hand and oft' ' e , / f f OPTIONAL j Though the information b is not required b ten; q may prove valuable to persons relying on the document and could prevent tiaudulent tamoval and taanadwwnt of this form to another document. Description of Attached Document Title or Type of Document: ' t Document Date: Number of Pages: Signer(s) Other Than Named Above: Capacity(ies) Claimed by Signer(s) ;. � Signer's Name: Signer's'Name: t O Individual Olndividual D Corporate Officer O Corporate Officer TIIIe(s): Title(s): D Partner — p limited D General ,CJ Partner — 0 Limited ❑ General O Attorney -in -Fact O Attorney -in -Fact D Trustee D Trustee O Guardian or Conservator O Guardian or Conservator D Other: lop p1 v6no heft O.Other: top Of tn,ulle he:e � Signer Is Representing: Signer Is Representing: i t I.1"' :/..Y . I (I•.. .1�: • rF�.`� I.' C� 111 `II.: Il.`,l A: �6• -• 1 NOV- 9 - 03 WED 02:31 PM ECSCandE INC FAX:019 253 7902 E'AGE 1 EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFOR,'NIA 92071 (619) 258 -7901 Fit% 258 -7902 Eric Murphy November 19, 2003 ELM Enterprises :.'rojoC.t. No . 0 396 North Coast H'.i.ghway 1.01 Encinitas, California 92024 Subject: Limited Site Investigat_on Proposed Two -Story Office and Re wdential Buiid:Lrng 631, :3 Street, APP 258- -i3 °0 C:i.ty of Encinitas, Cali :1ia Dear Mr. Murphv: In accordance wi,.th your request, we h-.:Te performed a limited investigation of the soil conditions a'.: the subject site. The investigation was undertaken to provi.,;ie the soil engineering criter. i,a for site grading and recommend an aopropr.i.ate foundation system for tt'jc pr'oposeci office and resider`ial. building. Our investigation found that the site :_s underlain by topsoil and colluvi.um to a. maximum depth of 4.5 fe=y= below existing grade. Medium dens: to dense sandstone of the Tc_:rrace Depcsits Formation was underlying the colluvium. It is our opinion that the propcsc' 'levelopment is feasi_b_e Provided the recommendations herein A— implement =d during constr..uction. Res'pec;ttully Mamaldou Salina D allo, ►'. F Rc.;F. 54071 • NOV °1.9 WED 02:31 PM ECSCandE INC FAX:6:9 253 7902 PACTE 2 ELM ENTERPRISES PROJECT NO. 03 - 11 4 7B 7(1) INTRODUCTZON This is to pr,eserit the findings and conclusions of a soil investigation for a proposed two -story office and residential building to he located on the east side 3rd Street, in the City of Encinitas, californi.a. The objectives of the investigation were to evaluate tre existing soils conditions and provide recornmendations for the proposed construcL'ion. In order to accomplish these objectives, three (3) exploratory borings were drilled to a maximum depth of 6.0 feet; undisturbed and loose bag samples were obtained, anc: laboratory tests were performed. SITE DESCRIPTION AND PROPOSED CONSTRUCTION Th subject sift-: is located on the east side of 3rd Street, in the City of x,nciriitas, California. It is presently occupied with a single -story home that will be demolished. The property slopes moderately to the southeast. Site boundaries include 3rd Street to the west, an alley to the east, an office building to the south and a residential parc;ei to the north. Vegetation consisted of a few trees, shrubs and grass. ].t is our understanding that the proposed cori.struction will include a two--story, wood framed, office and rF�sidential building. The structure will be founded on continuous footings with a slab - on - grade floor. FIEID INVESTIGATION On November 3, 2003, three (3) exploratory borings were drilled to a maximum depth of 6.0 feet with a h:.ind auger. The approx.imate locations of the borings are: shown on ;_he attached Plate too. 1, entitled "Location of Expicratcry Borings ". A conv_iri,ous ioq of the s( cnc_ountered was re:orded at tie timc of exCavac_on and is shown on Plate No. 2 entitled "Surrnary :ghee "_ ". The :oils were v�.sually and �eytural.l y classified accordi. ng to the filed identi,ficr:Lion procedures set forLh on the atta Flat No. 3 entitied "Cni form sc_,11 is l pssifica � :harp_ ". NOV - 19 - 03 WED 02:32 PM ECSCandE INC .;V:1 25c 7902 PAGE ELM F.N7 ERPRISES PROJECT NO. 03-1147B7(l) SMGRADE CONDITIONS Topsoil and colluvium were encountered to a maximum depth of 4.5 feet below existing grade. These soi_s generally consisted of silty sand with a loose to medium dense consistency and low moisture content. The colluvium was underlain by medium dense to dens: sandstone oL the Terrace Deposits Formation. EXPANSIVE SOILS An expansion index test was performed on a select sample of the colluvium to determine volumetric change characteristics with change in moisturc content:. An expansi ? index of 2 indicates a very low expansion potcnti.al for the foundaLi_on soils. GROUNDWATER Groundwater was not encountered during the course of our investigation. SLatic groundwater is anticipated at depths greater than 100 feet. We do not expect groundwater_ to affect the proposed development. GEOLOGIC HAZARDS A review of the available geological literature pertaining to the site indicates the existence cf t - -e Rose Canyon Fault Zone approximately 4.0 ?gym to the wes -. Ground shaking from this fault or one of the major active faults in t::- region is the most likely happening to affect the site. with respect to this hazard, the site is comparable to others, in the ge :.er.al area. The proposed c)ftiCc and residcntial s *,_ucL'ure should be designed in accordance wiL'h seismic design requirements of the 1997 'Uniform Building Code or the Structural t.ngineers Associa -ion of California using the following seismic design parameters: PARA1VlCE F,R 'V ALUE — C JBC REF Seismic Zone Factor, 7 1 0.40 'fable 16 -I Seismic Source B Table 16 -U So Profile `1' __....__ ...... _._ -- Y!x So Table 16 -J ......_ ....- - - l -- Near- Sour f actor, Na .1 'fable 16 - Near - Sour F actor, NV i 1.3 Table 1 -T S eistnic Coefficien Ca 0.48 Ta ble 16 - I S eisrnic Coeff icient. Cv 0.83 Table 16 - NOV -03 WED 02:32 PM ECSCandE INC FAX;619 258 7902 FAGH 4 ELM ENTERPRISES PROJECT NO. 03.1147R7(l) Based on the absence of shallow groundwater and the cons:�stency of the underlying Terrace Deposits F ormation, it is our, opinion that the potential for liquefaction is very low. CONCLUSIONS AND RE'CO)OWNDATIONS The following conclusions and recommendations are based upon the analysis of the data and information obtained from our soil investigation. This includes visual inspection; field investigation; laboratory testing and our general knowledge of the soils native to the site. - -he site is suitable for the proposed development provided the recommendat set forth are implemented during construction. GRADING AND EARTHWORK Site grading should begin witt clearing arid grubbing, removal of the existing structures, vegetation and deleterious materials. I'he subgrade soils extending to a depth of approximately 4.5 feet below existing grade and at least five (5) feet beyond proposed perimeter footings should be overexr_- aVated, moisture conditioned within 3 percent o optimum and compacted to a minimum of 90 percent relative compaction. 'l'he actual depth and extent of removal should be evaluatec in the field at the time of excavation by a representative of this firm. Grading should be performed in accordance with the attached appendix A. FOUNDATION AND SLAB a. Continuous and spread footings are suitable for use on .Site. Continuous footircrs should extend a mi-nimurr. of 18 inches for the two - , story bu.i.lding ir' c) he properly c:cr.pa�;tcd fill soils. These footi.ngs should be at least 1.5 inches in width and reinforccd with four 1 #4 steel bars; two bars placed near the top of the footings and the other t.wn bars placed near the bottom of the footings. b. Concrete fl,o��r slabs should be a minim -im of 4 inches, thick. Reinforcement should consist of 43 bars placed at 18 inches on center cacti way. Slab reinforcement st ould be placed Within the middle thi..:d of the slab by support_r:a the steel. nn _hairs or concrete blocks "dobies" . '­he slab shcu.d be underlain by 2 inches of clean sand ovF�r a 10-•mi..', vi squeen mcist. ire barrier. 4 NOV-19 -03 WED 02:32 PM ECSCandE INC FAX,619 258 7902 PAGE 5 ,'LM ENTERPRISES PRO.IEC?' NC . 03- 1147B7(1) The effect. of concrete shrinkage will result in cracks in virtually all concrete slabs. To reduce the extent of shrinkage, the concrete should be placed at a maximum of 4 -inch slump. The minimum steel recommended is not intended to prevent shrinkage cracks. c. Where moisture sensitive floor coverings are anticipated over the slab, the 10-1111.1 plastic moisture barrier should be underlain by a capillary break at least 2 inches thick, consisting of coarse sand, gravel or crushed rock not exceeding 3/4 inch in size with no more than 5 percent passing the #200 sieve. d. An allowable soil bearing value of 2,000 pounds per square foot may be used for the design of continuous and spread footings at least 1.5 inches wide and founded a mini-num of 18 inches into zhe properly compacted fill soils. This vale may be increased by 650 psf percent for each additional foot of width or depth to a maximum value of x,000 lb /ft2. e. Lateral. resistance to horizontal movement may be prov1ded by the soil passive pressure and the friction of concrete to s0_1. An allowable passive pressure of 250 pounds per square foot per foot of depth may be used. A coefficient o friction of 0.35 is recommended. The soils passive pressure E's well as the aea.ricjcl value may be increased by 1/3 for wind and seismic loading. RETAINING WALLS Cantilevered retaining walls with a level backf..11. may be dcsigned tC) rP..SlSt an active 9C(U1V %Vent fluid p;-essllre of 35 pounds per cubic foot, while retaining walls with a 2:1 (horizontal to vertical) sl.opi.nc; backfill may be designed to resist an active equivalent fluid pressure of 45 pounds per cubic foot. This pressure is base-; on the bac•kfil]. soils being free dra Lni,ng and non-expansive. Fiack`iii materials must 'Oe approved by the soi_is engineer prior to uz. e . NOV-719 - WED 02:33 Phi ECSCandE INC FAX;bi9 258 7902 PAGE 6 ELM ENTERPRISES PROJECT NO. 03-1147B7(1) Restrained walla, such as basement wails, that are not free to rotate should be designed to resist an "at- rest" equivalent fluid pressure of 60 pounds per cubic foot. Restrained walls subject to uniform surcharge loads should be designed for an additional pressure of one -half the anticipated surcharge. SETTLEMMT Settlement of compacted fill soils is Normal and should be anticipated. Because of the type and thickness of the f- soils under the proposed footings and the light building loads, settlement should he within acceptable 1,,.mits. UTILITY TRENCH EXCAVATION AND BACKFILL Excavations for on-site utility trenches may be made vertically for shallow depths and must be either shored or sloped at 1H: 1V for depL,hs greater than S feet. Utilities should be bedded and backfilled with clean said or approved granular soil to a depth of at least_ one fool, over the pipe. This bazkfill should be uniformly watered and compacted to a firm condi.t for pipe support. The remainder of the backfill should be on-site soils or non - expansive imported soils, which should be placed -n thin lifts, moisture conditioned and compacted to at least 90 ° relative compaction. DRAINAGE Adequate: measures should be undertaken t.> properly finish grade the site after_ tile structure and other improvements are in place, such Lhat thc d"ainatge water within the site and adjacent, properties is directed away from the foundations, footings, floor slabs and the toes of slopes vla surface swales and subsurface drains towards the natural, drainage for this area. Proper surface and subsurface drainage will be required to minimize the potential Of water seckinq the level of the bearing soils under the foundations, foot .nqa and f 1oor slabs, which may otherwlse resu�.t. in undermining and: differential settlement of the structures and other. irnprovernerits . t NOT -19 -03 WED 02:33 PM ECOCandE INC FAX :019 258 7902 FA +:iE 7 ELM F,N'1'ERPRISESPROJECT NO. 03-1147B7 .LIMIT$ OF XMMSTIGATION The recommendations provided in this report pertain only to the site investigated and based upon the assumption that the soil conditions do noL deviate from those disclosed in the borings. If any variations or undesirable conditions are encountered during construction, or if the proposed construction will significantly differ from that pianned at the present time, East Col_:nt.y soil Consultation and Engineering, Inc. should be noLif,ieri SC that, supplemental recommendations can be prov�.ded. Plates No. 1 through 3, Pages L and r, - 2, Ref.ere - es, and Appendix A are parts of this r.ercrL. Respectfully svhmitted, -ou SDI R No. C 05471 ° Jj Cam, VL Mamadou Saliou Diallo RCE 590)1 MSD /md 7 WV -.9 -03 WED 02 33 PM ECSCandE INC , AX:6;9 �5� '9G2 PAGE 3 ilb I � v 1 t EAST COUNTY SOIL CONSULTATION & ENGINEERING, INC. 10925 HARTLEY RD � SUM 1. SANTEE CA 92071 '� (619) 25M-7901 Pax (619)2SR -7902 NOV - 19 -03 VIED 02 , 33 PSI ECS'CandE INC FAX :6 1 9 258 7902 '� c FAi_xE ) F,GM F.N7'ERPRISES PRO IECT NO 03- 11=1787(1) PLATE NC. 2 SUMMARY SHEET NO. 1 BORIN(, NO. 1 DEPT SOIL DESCRTPTION Surface TOPSOIL dark brown, dry, loos<,, silty fi.n grained sand with rootlets 1.0' COLIIUVIUM (Qa 1) brown, dry, loose, fire grained slaty Sane! (SM) 2.5' 10'r.. 5. 4.5' TERRACE DEPOSITS (Q`,) tari, ;noisy., medium dense r,o `.: n= grained si.1ty sand (SM) 6.0' bottom of boring„ ri:, caving no grouridwater boring backl•i. lied ].7/3/03 SORTING No. 2 DEPT!-' SOIL DFSC RIPTION Y M Sur face TOPSOIL dark brown, dry, icose, si_Ly fine grained sand With root i . 0' COLLWIUM (Qa ;. ) brown, dry to mois', loosi: to medium ;sense, fire grained silty sind (S! 4.()' TERRACE DEPOSITS tan, moist, medi+.rrt c Cn: 5e to c-lense, `'ine < :ra BEd ,i lty ;and (SM) 510' biJCtnm of bnrinc:, no caving, nc boring :1/3/03 HOR -'.iG DEC a D^PTH S(, DESC :SIP - IUN Y h; Sur. TOPSOIL Dark br.nwr., dry, 100-70-, 511� fi:;e . 0' COLLW IUM '' Q a i ) a-gwn, d y to moi s', to met lu:', 10 ; a �. 4.5' '1v'ERRACE DEPOSITS ,Qr tan, mo - rncdi.i;n dense Ln dcns(-, tine kirzinec;. i...It.y sar,3 (SM^ 5.i)' bott:om t:,c:,r1. -, :l;_ ...iV ..;rj i,C .J'r'.•1 :P. (l r bey :ins; be;_kr :ii1.eid 7]/3/0.3 NOV - -03 WED 02;34 PM ECSCandE INC __ FAX; 519 158 7902 ;AGE 11 MAJOR DIVISI SXMOL DESCRIPTI Gw WELL GRADED GRAVELS OR GRAVEL. SAND MIXTU LITTLE OR N O FINES GRAVELS GP (MORE THAN 'h POORLY GRADED GRAVELS OR GRAVEL -SAND OF COARSE MIXTURES. LITTLE OR NO FINES FRACTION GM >N0. 4 SIEVE SILTY GRAVELS, GRAVELSAND -SILT MIXTURES COARSE GC cC CLAYEY GRAVELS, GRAVEL -SAND -CLAY MIXTURES GRAINED SOILS _ (MORE THAN % OF SOIL > SVV NO. 200 SIEVE SIZE) WELL GRADED SANDS OR GRAVELLY SANDS, LITTLE OR NO FINES SANDS Sp _.. _ (;MORE THAN Y_ POORLY GRADED SANDS OR GRAVELLY SANDS. OF COARSE :. __, OR NO FINES FRACTION SM NO. 4 SIEVE SILTY SANDS, SILT-SAND MIXTURES : SIZE) _.. SC CLAYEY SANDS, SAND -CLAY MIXTURES - ML INORGANIC SILTS AND V RY FINE SANDS, ROCK FLOUR. SILTY OR CLAYEY FINE SANDS OR CLAYEY S ILTS & SILTS WITH SLIGHT PLASTICITY CLAYS CL INORGANIC CLAYS OF LOW TO MEDIUM LIQUID LIMIT PLASTICITY, G RAVELLY CLAYS, SANDY CLAYS, FINE GRAINED `30 OL SILTY CLAYS, LEAN CLAYS SOILS ` ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW P (MORE THAN Yz OF SOIL c MCI — ` -- NO. 200 SIEVE SIZE) INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS SILTS & FIN SANDY OR SILTY SOILS. ELASTIC SILTS CLAYS CSI INORGANIC CLAYS OF HIGH PLASTICITY, FAT LIQUID LIMIT .050 j __ CLAYS OR ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, O RGANIC SILTY CLAYS. ORGANIC SILTS IfIGHLY ORGANIC SOILS pt PE AND OTHER HIGHLY ORGANIC SO ILS CLASSIFICATION CHART (UNIFIJED SOIL CLA SYSTEM) 7° - Ft SIFICATION RANGE OF GRAIN SIZES I I i G.S. STANDARD I GRAIN SIZE IN I — I I ` SIEVE SIZE I MILLIMETERS BOU 121nc Abov 305 I 6 I 1 ca - COBBLES 1 12 ln0e$ To 3 Inches 3 To`76.2 1 (RAVEL 3 Inches to uo 4 76.2 to 3.76 I I Coarsc 3 1ncaB5 t0'/, Inch 76.: to 19.1 9 70 ` I C I Y I Finc I ': Itch to No 4 19 1 to 4.7 o ` SAND 1 No. 4 to No 200 4.76 to 0.07s I �acw Cotu5e No. 4 to No. 10 4_ ,6 to 2.00 + 10 i Medlum No 10 Co No 40 1.00 to 0 420 c =�c :;Nn• ,� inc _ _N0.40 to No. 200 0.120 to 0.0 a SILT AND CLAY I B clow Nu. 21 00 I Balo 0 .074 I ° 1-3 i° w so ;a ?n 30 9a co ucum GRA SIZI; CHART PLASTI CH;kR'1' - EAs , r COUNTY SOIL CONSULTATION AND ENGINEERING, INC. ( ELM ENTERPRISES PROJECT ' I0925 HART LEY ROAD. SUI TE SANTEE, CALIFORNIA 920 -1 FROJEC'1 NO. 03-1147B7 1 PLATE PTO. 3 U.S. SOIL C I AS , N6V - -03 WED 02;34 FM ECSCandE INC FAX:6I9 250 7902 FADE III F1,.M F,NTF.RPRISES PROJECT NO. 03-1147B7(1) PAGE L -1 LABORATORY TEST RESULTS MAXIMUM .DENSITY AND OP'T'IMUM MOISTURE TEST RE,SUI.TS The maximum dry densities and optimum moisture contents of the .fill materials as detemiined by ASTM D1557 -91, Procedure A which uses 25 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4 inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a I0 pound slide hammer falling from a height of IS inches on each of 5 equal layers in a 6 inch diameter 1'133 cubic foot compaction cylinder are presented as follows: OPTIMUM MAXIMUM MOISTURE SOIL TYPE/ DRY DENSITY CONTENT PRO(' EDLJRF DF.SCRTPTTON LR/ CU. FT- % DRY WT. LOCATION 1/A BROWN, SILTY 131,0 8.2 I3 -1 (a F -4' FINEE- GRAINED SAND RESUL'T'S OF EXP NDEX TEST An expansion test in confbrmance with ASTM D4829 was performed on a representative sample of on -site foundation soils to determine volumetric change characteristics with change in moisture content. The recorded expansion of the sample is presented as follows: INITIAL SATURATED INTT'IAT, DRY MOISTURE MOIS'T'URE DENSITY EXPANSTON CONTENT% CONTEEN71% INDEX LOCATION 7.0 11.9 116.6 2 B -1 (� 2 -J NOV WED 02:34 PM ECSCandE INC FAX : F 19 25° 7902 PAc :7E 12 F, I.M EMERPRI,SF,,S PROJEC2' NU. 03- 1147B-I(1) PAGE L -2 LABORATORY TEST RESULTS RESULTS OF PARTICLE SIZF. ANALYSIS ! U S, Standard ...__ .... .... . Percent Passing Percent Passing Sieve Size B-4 @ 1.0'- 4.0' B -2 @ 4.0' ;..__ (ASTM D 422) _ 3„ - - 1/2" 3/8" - #4 - #8 100 - #16 99 100 #30 85 8' #60 34 3> #lU0 23 24 #200 20 18 1 1SCS SIVI SNI 1 !1 NOV-J9 -03 WED 02:34 PM ECSCandE INC rAX:E19 258 7902 F1 -NlEIVTERPRLSF;71'ROJECTNl.> 03- 11.17B7(I) REFERENCES 1. "1997 Edition, Uniform Building Cz,dc, Volume 2, Structural Engineering and Design Provisions ". 2. "Maps of Known Active Fault Near -- Source Zones in California and Adjacent Portions of Nevada ", Page 0 -36, used with the 1997 Edition of the Uniform Building Code, Published by International Conference of 51;ilding Off cials. 3. "Geologic Mans of the Northwestern Part. of San Diego County, California, Plate No. 2, Geologic Maps of the Encinitas and Rancho Santa Fe 7.5' Quadrangles ", by Siang S. Tan and Michael P. Kennedy, 1996. 11 NOV -19 -03 WED 02:35 PM ECSCandE INC FAX:619 250 7902 FA(iE 14 EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE. I SANTEE, CALIFORNIA 92071 (619) 258 -7901 APPENDIX A RECOMMENDED FARTHWORK SPECIFICATIONS 1. General Description The intent of these specifications is to obtain uniformity and adequate strength in filled ground so that the proposed structures may be safely supported. The procedures include the clearing and preparation of the land to be filled, processing the fill soils, the spreading, and compaction of the filled areas to conform with the lines and grades as shown on the approved plans. The owner shall retain a Civil Engineer qualified in soil mechanics (herein referred to as engineer) to inspect and test earthwork in accordance with these specifications. The engineer shall advise the owner and grading contractor immediately if any unsatisfactory conditions are observed to exist and shall have the authority to reject the compacted filled ground until such time that corrective measures are taken, necessary to comply with the specifications. It shall be the sole responsibility of the grading contractor to achieve the specified degree of compaction: 2. Preparing Areas to be billed (a) All brush, vegetation slid any biodegradable refuse shall be removed or otherwise disposed of so as to leave the areas to be filled free of vegetation and debris. Any uncompacted filled ground or loose compressible natural ground shall be removed unless the report recommends otherwise. Any buried tanks or other structures shall be removed and the depression backfilled to the satisfaction of the engineer. (b) The natural ground which is determined to be satisfactory for the support of the filled ground shall then be plowed or scarified to a depth of at least 12 inches (12 "). (c) After the natural ground has been prepared, it shall then be brought to the proper moisture content and compacted to not less than 90 percent :: i maximum dry density in accordance with ASTNI D1557 -91. (d) Where fills are made on slopes greater than 20 percent, horizontal benches shall be cut into the tirm natural ground. The initial bench at the toe of tl-o fill shall be at least 15 feet in width on firm undisturbed natural ground. The width of all succeedi:ig benches shall be at least 6 feet. NOV 9 -43 WED 02: 35 FM ECSCandE INC FAX: 258 7902 ?ACj APPENDIX A � 3. Fill Materials All material shall be approved by the engineer and shall consist of materials free from vegetable matter, and other lumps greater than 6 inches in diameter. If, during grading operations, soils are found which were not encountered and tested in the preliminary investigation, tests on these soils shall be performed to determine their physical characteristics. Any special treatment recommended in the preliminary or subsequent soils reports not covered herein shall become an addendum to these specifications. 4. Placing and Compacting Fill Materials (a) When the moisture content of the fill material is below that specified, water shall be added until the moisture content is near optimum to assure uniform mixing and effective compaction. (b) When the moisture content of the fill materials is above that specified, the fill material shall be aerated by blading and scarifying or other satisfactory methods until the moisture content is near optimum as specified. (c) After processing, the suitable fill materials shall be placed in layers which, when compacted, shall not exceed six inches (6 "). Each layer shall be spread evenly and shall be thoroughly mixed during the spreading insure uniformity of materials and moisture in each layer. (d) After each layer has been placed, mixed and spread evenly, it shall be thoroughly compacted to not less than the density set forth in paragraph 2 (c) above. Compaction shall be accomplished with approval types of compaction equipment. Rolling shall be accomplished while the fill material is at the specified moisture content. in place density tests shall be performed in accordance with ASTM D 1556-90. (c) The surfaces of the fill slopes shall be compacted by means of sheepsfoot rollers or other suitable equipment. Compacting operations shall be continued until the slopes ue stable and until there is no appreciable amount of loose soil on the slopes. 5. Inspection Sufficient inspection by our firm or the Soil's Engineer of record and /or his /her representative shall be maintained during the filling and compacting operations so that he /she can verify that the fill was constructed in accordance with the accepted specifications. 6. Seasonal Limits No fill material shall be placed, spread, or rolled if weather conditions increase the moisture content above permissible limits. When the work is inimupted by rain, fill operations shall not be resumed until the moisture content and density of fill are as pre-, 1.0usly specified. All recommendations presented in the attached report are : =art )l'these specifications.