Loading...
1998-5388 I (Plans) GENERAL NOTES SEWER MOTES: CARDIFF SAWATiON DfSTMCT 1. A PERMIT SHALL BE OBTAiNED FROM THE CiTY DEPARTMENT OF PUBLIC ALL WORK SHALL 8E DONE MV ACCORDANCE WITH THE STANDARD WORKS FOR ANY WORK WITHIN THE STREET RIGHT OF WAY. 2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH THE CiTY OF SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION [LATEST EDiTiOM, THE ENCINITAS STANDARDS AND AS APPROVED BY THE CiTY ENGINEER. R VALUE SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE STANDARD p�► TESTS SHALL BE REQUIRED PRIOR TO CONSTRUCTION. SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, [ADOPTED BY THE SAN r*� L STANDARDS COMMITTEE], THE SAN DIEGO REGIONAL DIEGO REGION �s 3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF CONSTRUCTION OUTSIDE THE PROJECT STANDARDS " TEST EDITION] AND THE FOLLOWING SPECIAL PROVISIONS:. ate BOUNDARY. 1. TRENCH WIDTH SHALL BE PER SDRSD NOOTHERWISE NOTED. WITHIN � ��� � ♦�� . 4. ALL UNDERGROUND UTILtTiEWITHIN THE STREET RIGHT OF WAY SHALL . S-4 UNLESS OTHE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF 2. PIPE AND BEDDING CONDITIONS: BE CON S , A. ALL PiPE SHALL HAVE 4" MINIMUM OF 314" CRUSHED ROCK BENEATH THE BERM, CURB, CROSS GUTTER AND PAVING. S. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES PiPE' 7 SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE B. V.C.P. AND A.B.S. TRUSS PIPE BEDDING FRO M BOTTOM OF PIPE TO 12" RECORDS TO THE BEST OF OUR KNOWLEDGE. THERE ARE NOT OTHER MINIMUM ABOVE THE PIPE SHALL BE SAND, GRAVEL, CRUSHED AGGREGATE, '� N, S � EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER THE NATIVE FREE - DRAINING GRANULAR MATERIAL HAVING A SAND EQUIVALENT C` 30 OR BETTER. CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO OF c C. P.V.C. AND A.B.S. SOLID WALL PIPE BEDDING FROM BOTTOM OF PiPE TO , PROTECT ANY EXISTING FACILITY SHOWN HEREON AND ANY OTHER WHICH IS F NOT OF RECORD OR NOT SHOWN ON THESE PLANS. 12" MiNIMIUM ABOVE THE PiPE SHALL BE 3/4" CRUSHED ROCK. A-B.S. SOLID ti 6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE WALL PIPE MAY BE USED ONLY WHERE PiPE INVERT GRADES ARE 1% OR DONE SHALL BE CONFIRMED BY HELD MEASUREMENTS PRIOR TO GREATER. yl CI N �'r� M/� CONSTRUCTION OF NEW WORK. CONTRACTOR WILL MAKE EXPLORATORY 3. AFTER COMPLETION OF PiPE LAYING, ALL MAiN LINE SEWERS, SEWER No SCAL EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES SERVICE LATERALS AND STRUCTURES SHALL BE TESTED IN THE PRESENCE SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF OF THE INSPECTOR. AIR PRESSURE TEST SHALL BE USED UNLESS OTHERWISE DIRECTED BY THE INSPECTOR. REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING 4. THE E ONSTRUC ON OF PCC SEWER MANHOLES SHALL BE PER SDRSD NO. FACILITIES. 7. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS AND ELECTRIC S-17. POURED IN PLACE MANHOLE BASES SHALL BE A MONOLITHIC POUR ? COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL FINISHED COMPLETE AT TiME OF POUR. PRECAST MANHOLE BASES ARE COORDINATE THE WORK WITH COMPANY REPRESENTATIVES. NOTICE: ALL ACCEPTABLE FOR USE WITH 8" COLLECTOR SYSTEMS WITH INSPECTOR'S ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE UNDERGROUND APPROVAL. INSTALLATIONS. FOR LOCATION OF ELECTRIC CABLES AND GAS PIPING 5. THE CONSTRUCTION OF 4" SEWER LATERALS IS PER SDRSD NO'S S-13 AND CONTACT THE SAN DIEGO ELECTRIC AND GAS COMPANY AT I-M- 422.4133. S -14. LATERALS SHALL NOT DISCHARGE DIRECTLY INTO MANHOLES. & THE CONTRACTOR SHALL NOTIFY THE PACIFIC BELL TELEPHONE COMPANY 6. ALL MAINS AND LATERALS SHALL BE CONSTRUCTED WITH 42" MINIMUM PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COVER. COORDINATE THE WORK WITH COMPANY REPRESENTATIVES. NOTICE: ALL 7. THE FINAL LOCATION AND ELEVATION OF SEWER LOCATION AND TELEPHONE SERVICES WITHIN THIS PROJECT BOUNDARY ARE ELEVATION OF SEWER AND WATER MAINS AND LATERALS SHALL BE SHOWN UNDERGROUND INSTALLATIONS. FOR LOCATION OF CABLE AND ON ORIGINAL AS BUILT PLANS PRIOR TO ACCEPTANCE OF THE WORK. APPURTENANCES CONTACT THE PACIFIC BELL TELEPHONE COMPANY AT 1- WRITING P O PRIOR CCEPTANCE A D ALL DESIGN CHANGES ENGINEER IN WR FOR PUBLIC USE. 900-422-4133. D t. IT SHALL BE THE RE�iTY OF THE DEVELOPER TO CONTACT THE 9. FILL AREAS MUST BE COMPACTED TO 90% PRIOR TO PIPE INSTALLATION. DISTRICT FIELD OPERATIONS UTILITY AGENCIES, ADVISE THEM OF THE PROPOSED IMPROVEMENTS AND 10. THE CONTRACTOR SHALL NOTIFY THE 'S THE COSTS OF RELOCATIONS, IF NEEDED. DIVISION 48 HOURS IN ADVANCE OF BEGINNING WORK TO ARRANGE FOR BEAR INSPECTION OF PROJECT. PHONE NO. 760 -633 -2770• 10. ALL TELEVISION SERVICES WITHIN THIS PROJECT ARE UNDERGROUND • INSTALLATIONS. FOR LOCATIONS OF CABLES AND APPURTENANCES 11. CONTRACTOR SHALL OBTAIN A PERMIT FROM THE CITY'S ENGINEERING CONTACT THE APPROPRIATE CABLE TELEVISION COMPANY. SERVICES DEPARTMENT FOR ANY EXCAVATION WITHIN EXISTING CITY RIGHTS 11. THE CONTRACTOR SHALL REQUEST A PRE CONSTRUCTION MEETING OF WAY L E GE N O PROVIDE FROM THE CiTY ENGINEER'S OFFICE AND SHALL PROVIDE AT LEAST 48 HOURS 12. THE CONTRACTOR SHALL AND HEREBY DOES GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK BY DE SC RI PT i O N OW G No. SyNltso L.. Q OA N'r rr NOTICE FOR SUCH A MEETING. PHONE NUMBER: 3 -2770 12. POWER SOURCES AND RUNS SERVING STREET LIGHTS SHALL BE SHOWN THE OWNER AND SHALL REPAIR OR REPLACE ANY OR ALL SUCH WORK, HALL BE TOGETHER WiTH ANY OTHER WORK WHICH MAY BE DISPLACED IN SO DOING, Q COSST. Ty PE A -4 C.O. (3 or1LY) SDRSD D-9 ❑ 2 EA « . ON THE AS BUILT" IMPROVEMENT DRAWINGS. ALL SOURCES SHALL MAY PROVE DEFECTIVE iN WORKMANSHIP AND /OR MATERIALS WITHIN LOCATED WITHIN THE DEDICATED R.O.W., OR WITHIN EASEMENTS DEDICATED THE ONE YEAR PERIOD FROM DATE OF ACCEPTANCE WITHOUT EXPENSE INSTALL 16" RcP - D =Z4o0 ']6 L.F. TO THE CiTY OF ENCINITAS. WHATSOEVER TO THE OWNER, EXCEPTING ORDINARY WEAR AND TEAR, Q COM5`f STORM OKAIN LUG 502 50 ID 1 cA ER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR SEAVIEW VILLAS, LLC, A CALIFORNIA LIMITED LUIBIUTY COMPANY 13. THE DEVELOP UNUSUAL ABUSE OR NEGLECT. BENCH MARK WHiCH IS DISTURBED OR DESTROYED SHALL BE RE- 3. CONTRACTOR SHALL FURNISH AND INSTALL, PER SPECIFICATIONS, THE C/O ROBERT MUELLER CONSTRUCTION, INC ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A 1 3525 DEL MAR HEIGHTS ROAD, 6344 LICENSED LAND SURVEYOR. APPROPRIATE BURIED UTILITY WARNING AND IDENTIFICATION TAPE ABOVE SAN DIEGO, CA 92130 ALL PUBLIC SEWER LINES AND PORTIONS OF SEWER LATERALS LOCATED 14. THE DEVELOPER SHALL MARK THE LOCATION OF EACH SEWER LATERAL WATER SERVICE BY CHISELING THE LETTERS "S" AND "1M', WITHIN PUBLIC RIGHT OF WAY OR EASEMENTS 10 C ONNECT TO EX1 SEWER i MA. AND 14. "AS BUILT" DRAWINGS MUST BE SUBMITTED PRIOR TO FINAL RESPECTIVELY, 2 INCHES HIGH INTO THE FACE OF CURB. ACCEPTANCE OF THE WORK. 1 IN STALL b" PV C (Gm)o0 v r) RESTRAtp nlwT5j S 78 1 '••F 15. THE ADDRESS OF EACH LOT SHALL BE PAINTED ON THE CURB IN A 15. NEW SEWER MAINS LESS THAN 36" IN DIAMETER SHALL BE INSPECTED BY Q IN STALL q" SEwEtL LATERAL t . si3, S i°) 3 EA• , MANNER AND LOCATION AP PROVED BY THE INSPECTOR. CLOSED CIRCUIT TELEVISION AFTER COMPLETION OF TRENCHING BACKFILL IN STALL. MA1NLIUE SEWER. C. S 3 I EA j 16. ALL WORK SHALL BE DONE IN ACCORDANCE WiTH THE STANDARD FINISHED GRADING BUT PRIOR TO PLACEMENT OF PAVEMENT OR D • . SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION [LATEST EDITION], THE AND FINIS SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE STANDARD PERMANENT TRENCH RESURFACING. CONTRACTOR SHALL PROVIDE FOR SITE ADDRESS: PUBLIC WORKS CONSTRUCTION [ADOPTED BY THE SAN TELEVISION INSPECTION [SEC. 306- 1.4.81. TA PUBLIC COMMITTEE], KS O AND THE SAN DIEGO REGIONAL 16. WASTEWATER DISCHARGE PERMITS AND PLUMBING PERMITS ARE ® INSTALL 1� WATER sERv I c EA E 0- 2 2146, 214x, a 2150 M SPECIFICATIONS FOP. AVE. DIEGO REGIONAL S REQUIRED PRIOR TO CONNECTION TO SYSTEM. S TANDARD DRAWINGS TEST EDITION] Q RELOCATE EXI STI WA�Q SERVI 1 EA CARDIFF, CA 92007 S [LA TEST PARCEL NUMBER TRENCH RESUIC�ING �T4 pE A) _ SDRSd SM -1 �ZZL 3b b SF. 26i -061 •40,41, i 42 V . OWNERS CERTIFICATE LEGAL DESCRiPTON: IT IS AGREED THAT FIELD MAY REQUIRE CHANGES TO'THESE DECLARATION OF RESPONSIBLE CHARGE LOTS 11,12 AND 13 OF BLOCK 90 PLANS MAP 81298 � I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, IT is FIR AGREED THAT THE CIVViNER/DEVEL OPER SHALL HAVE A THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE ' r REGISTERED CIVIL ENGINEER MAKE SUCH CHANGES, ALTERATIONS OR PROJECT AS DEFINES IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS ADDITIONS TO THESE PLANS WHICH THE DIRECTOR OF PUBLIC WORKS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. DETERMINES ARE NECESSARY AND DESIRABLE FOR THE PROPER T'OPdGFtAPHY BY: ' COMPLETION OF THE IMPROVEMENTS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND I V SPECIFICATIONS BY THE CiTY OF ENCINITAS IS CONFINED TO A REVIEW ONLY 535 N RE SURVEYS, iNC. (FURTHER AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS SHOWN ON AND DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY S36 NORTH SOLANA BEACHCH, C, CAA. . 92200 75 • SUITE G V THESE PLANS WITHIN EXISTING CITY RIGHT OF WAY WITHIN 60 DAYS AFTER RESPONSIBILITIES FOR PROJECT DESIGN. �8/ ISSUANCE OF THE CONSTRUCTION PERMIT AND TO PURSUE SUCH WORK Z 0. s S AL WORKING DAY UNTIL co L COMPLETED, / K ASSOCIATED WITH THE SEA BRIGHT COMPANY h Q ACTIVELY ON EVERY NORM co IRRESPECTIVE AND INDEPENDENT OF ANY OTHER WORK 4322 SEA BRIGHT PLACE , THIS PROJECT OR UNDER MY CONTROL. CARLSBAD, CA 92008 * sal -o: * j" clv�- NorE NO NEW FIRE HYDRANT Witt. 8E REQUi'fZED W `oFrJ►►. PRov1DED THE 15UILb}NGS ATE FULLY 1=1VE CALIFORNIA LIMITED LIABILITY CO. 'T 21 9 OWNERS: SEAVIEW VILLAS, LLC, A . BY �. DATE 8 51'RIN1Cl -EREd. RO ERT O. SUKUP RCt 28302 /o -ib - 98 AS 130 1Ur W SIGNATURE: ROBERT MUELLER DATE Q - ROBERT Q Sv KUP r-- � SIGNATURE DATE ' 3� 1� a 283oZ � • • ENCIUITAS F 112-E PROTECTION DST. DAs RAE - W W - REV I EVJEb tiY' .._ Z W pA-re : 9 0 Z E E E W Q AS H RING D PARTMENT DRAWING N 0. ALS C OF ENCINITAS T REFERENCES DATE BENCH MARK SCALE SPECIAL DISTRICT APPROV i"T'1r REVISIONS APPROVED DA s ALT • °� w tot sRtoc,E�1A7�61 N DIE �v ATER DISTQtG'T PLANS PREPARED UNDER SUPERVISION OF RE CO M N E A OV A LL E y i M PROV E 1�tE1�iT 5 8" SEWE MAIiJ 538 8 - Z >3U oESGR�PTICN H Y _ �� O �-- DATE : til is gY BY: CROSSES SAN EL - 1-'0 LAGOON HORIZONTAL I� REVIEWED NY: � �" 2-11(o ) 2 14 8 Z I S Q . NtAIJCNESTER AVE. C S" Z N.G. CoNclEsTE WING WAU., S-TN0 r, Z t DA 10 /1•111a o-�i� �. _ c R.C.E. NO. :2_ DATE: ZZ- DATE: O ISc STAMPED M' m 6b VERTICAL ENGINEER EXP. 3 311 WORK PROJECT N0. tO P, 940 2 I � ; S HEET OF 2 ELEV 19•'l°13 D ATUM : USC�GS SIGNATURE EY PiRE S L S FROM 017E I IZ4t3ERT o• suKuP W NoText