Loading...
1999-5851 I (Plans) i • GENERAL NOTES IM E T PLA FOR HYGEIA A VENUE WORK TO BE DONE ALL WORK SHALL BE DONE IN ACCORDANCE WiTH THE STANDARD SPECIFICATIONS 1. A PERMIT SHALL BE OBTAINED FROM THE CiTY OF ENCINITAS FOR PUBLIC WORKS CONSTRUCTION LATEST EDITION), THE SAN DIEGO STANDARD ENGINEERING SERVICES DEPARTMENT FOR ANY WORK WITHIN SPECIAL PROVISI TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS THE STREET RIGHT -OF -WAY. CONSTRU 58 ROW AND THESAN ( ADOPTED IEGO AREA REGIONAL STANDARD R DI ST DRAWINGS (LATEST EDITION). 2" OF � STANDARDS S HALL ID AS BE APPROVED BY THE CITY CITY WATER NOTES ENGINEER. A "R VALUE TEST SHALL BE REQUIRED PRIOR TO IMPROVEMENTS STD. DWG. SYMBOLS QUANTITIES CONSTRUCTION. SAN DIEGUITO WATER DISTRICT WATER MAINS 3 WIDE PUBLIC LATERALS AND APPURTENANCES SMALL BE 5 50 20 18 1 S S ROAD EASEMENT PROPERTY LINE 3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT 1. , GRANTED PER CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE CONSTRUCTED ACCORDING TO THE STANDARD SPECIFICATIONS 8.5 �.S 2 o Z w FINAL MAP PROJECT BOUNDARY. OF THE SAN DIEGUITO WATER DISTRICT. THE CONTRACTOR o CENTERLINE SWILL AND HEREBY DOES GUARANTEE ALL WORK FOR A PERIOD 5.0't as OF ONE YEAR AFTER THE DATE OF ACCEPTANCE. � � �0 1 4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY FEATHER FOR = v hoc `L' EXISTING CONTOURS SHALL BE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO 2 UNLESS NOTED, SMOOTH TRANSITION , CONSTRUCTION OF BERM, CURB, CROSS GUTTER AND PAVING. VARIES MAINS WILL BE MADE BY THE CONTRACTOR, UNDER THE 2X 2% 1x_2X EXISTING SPOT ELEVATION (95.20) 5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND SUPERVISION OF SAN DiEGUITO WATER DISTRICT, AFTER 2% t E ---� FACILITIES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH PAYMENT OF THE ESTIMATED COST BY THE DEVELOPER. PROPOSED CONTOUR 102 ti OF THE AVAILABLE RECORDS TO THE BEST OF OUR KNOWLEDGE. THERE ARE NO OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON 3. WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE EXISTING CURB AC OVERLAY 1530 SF THESE PLANS. HOWEVER, THE CONTRACTOR IS REQUIRED TO WATER MAIN PROFIE, TOP OF PiPE PROFILE IS 48 INCHES BELOW TAKE PRECAUTIONARY MEASURES TO PROTECT THE EXISTING CENTER LINE FINISH GRADE OF STREET. GUTTER AND SIDEWALK EXISTING TYPE G -.'r " CURB FACILITIES SHOWN HEREON AND ANY OTHER WHICH IS NOT OF AC PAVEMENT AC STRUCTURAL SE ON 1420 SF I KOLLEQ CUR137 RECORD OR NOT SHOWN ON THESE PLANS. 4. ALL SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS. TKl���IQ€"'.rA�14- - -- 6. LOCATION & ELEVATION OF IMPROVEMENTS TO BE MET BY WORK AC PAVEMENT OVERLAY CONSTRUCT ! G -4 180 LF TO BE DONE SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR 5. CONTRACTOR TO FURNISH ONE INCH COPPER WATER SERVICE AND METER BOX FOR EACH RESIDENTIAL LOT TO CONSTRUCTION OF NE WORK. CONTRACTOR WILL MAKE . " CONTRACTOR TO SAWCUT EXISTING A.C. STRUCTURAL SECTION � �� EXPLORATORY EXCAVATIONS AND LOCATE EXISTING UNDERGROUND 6. CONTRACTORS SHALL ACQUIRE A TRENCHING PERMIT FROM THE AC TO A NEAT EDGE UIN. 4" AC ON 6" AB FACILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT CALIFORNIA DIVISION OF SAFETY FOR ALL TRENCH WORK. CONSTRUCT CONCRETE DRIVEWAY G -14A 1 EA REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES TYPICAL CROSS SECTION HYGEiA AVE. EARTH SWALE 7. INSTALL FIRE HYDRANTS 2 FEET FROM BACK OF CURB, IF NO 7. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS do ELECTRIC SIDEWALK EXISTS, OR 7 FEET FROM FACE OF CURB WHERE STATION 5 +14 TO STATION 4 +95 COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SIDEWALK EXISTS OR WILL BE CONSTRUCTED. T. I. = 4.5 PROPOSED WATER LINE 17 LF SHALL COORDINATE HIS WORK WiTH COMPANY REPRESENTATIVES. NOT -TO -SCALE NOTICE: ALL ELECTRIC AND GAS SERVICES WITHIN THIS 8. PROVIDE AIR RELEASE ASSEMBLIES AT ALL HIGH POINTS IN PROPOSED FIRE HYDRANT SDWD P -1 1 EA PROJECT BOUNDARY ARE "UNDERGROUND WATER MAIN. INSTALLATIONS ". FOR LOCATION OF PROPOSED CURB OUTLET SDRSD D -25 1 2 EA ELECTRICAL CABLES AND GAS PIPING AND 9. CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT FROM 4 APPURTENANCES. THE CiTY OF ENCINITAS FOR ANY EXCAVATION WITHIN EXISTING TELEPHONE: 1 -800- 422 -4133 (DIG ALERT.) CITY RIG-OF -WAY. LEUCADIA BLVD. EXISTING SEWER LINE S S HTS Z FU/ 8. THE CONTRACTOR SHALL NOTIFY THE PACIFIC TELEPHONE COMPANY 10.THE DISTRICT REQUIRES THAT COMPACTION TESTS BE TAKEN = O EXISTING WATER LINE NM W PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES. s^ WHERE WATER LINES ARE INSTALLED WITHIN EXISTING COUNTY � RIGHTS -OF -WAY CITY OF ENCINITAS RIGHTS -OF -WAY, OR PRIVATE EXISTING GAS LINE G NOTICE: ALL TELEPHONE SERVICES WITHIN THIS � G PROJECT BOUNDARY ARE "UNDERGROUND Y O v INSTALLATIONS." FOR LOCATION OF ENCINITAS, BEFORE THE WATER LINES ARE ACCEPTED AND A Z EASEMENTS, THE RESULTS APPROVED BY THE CITY CUT SLOPE (2:1 MAX) CABLES AND APPURTENANCES CONTACT THE COPY SENT TO THE SAN DIEGUiTO WATER DISTRICT OFFICE. J TELEPHONE: 1 -800- 422 -4133 (DIG ALERT) o SiTE DAYLIGHiT LINE - - - - - - - - - 11. PRIOR TO AWARDING WATER LINE CONTRACT, OWNER SHALL 9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTACT ADVISE PROSPECTIVE CONTRACTORS TO OBTAIN AND REVIEW 1 WATER SERVICE W 6 EA THE UTILITY AGENCIES, ADVISE THEM OF THE PROPOSED CURRENT SAN DIEGUITO WATER DISTRICT'S SPECIFICATIONS. ENCINITAS BLVD. IMPROVEMENTS, AND BEAR THE COST OF RELOCATIONS IF NEEDED EARTHWORK QUANTITIES 10. ALL TELEVISIONS SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND 12•TNE CONTRACTOR SHALL NOTIFY THIS DISTRICT'S INSPECTION DEPARTMENT 48 HOURS IN ADVANCE OF BEGINNING WORK TO CUT 560 CY INSTALLATIONS*. FOR LOCATION OF CABLES AND APPURTENANCES ARRANG FOR INSPECTION OF PROJECT VICINITY MAP FILL 0 CY CONTACT: TELEPHONE 1 -800- 422 -4133 (DIG ALERT) NOT TO SCALE EXPORT 560 CY 11. POWER SOURCES AND RUNS SERVING STREET LIGHTS SHAD_ BE SHOWN 13. FILL AREAS MUST BE COMPACTED TO 90 W, PRIOR TO PIPE NOTE: ABOVE QUANTITIES REFLECT BOTTOM SURFACE ON THE 'AS- BUILT" IMPROVEMENT DRAWINGS. ALL SOURCES SHALL INSTALLATION. OF ASSUMED 10" STRUCTURAL SECTION BE LOCATED WITHIN THE DEDICATED RIGHT -OF -WAY OR WITHIN EASEMENTS DEDICATED TO THE CiTY OF ENCINITAS. 14.APPROVAL OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT QUANTITIES NOTE: DOES NOT CONSTITUTE A REPRESENTATION AS TO THE THE QUANTITIES ABOVE ARE ESTIMATED FOR BONDING AND PERMIT PURPOSES ONLY. 12. NO PAVING SHALL BE DONE UNTIL EXISTING POWER POLES ARE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR NON- CONTRACTOR IS RESPOSiBLE FOR VERIFYING ALL QUANTITIES AS A PART OF HIS BiD. RELOCATED OUTSIDE THE AREAS TO BE PAVED. EXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE 13. THE CONTRACTOR SHALL NOTIFY AND OBTAIN APPROVAL OF THE WITHIN THE LIMA of THIS PROJECT. OWNER /PERMITTEE LEGAL DESCRIPTION CITY ENGINEER PRIOR TO MAKING CHANGES IN THE FIELD. 15.ALL EXISTING FACILITIES WHICH MAY EFFECT FINAL DESIGN, I.E. KEVIN F. STEPHENS PORTION LOT 4, BLOCK "B MAP 1788 14. ALL SIGNS TO BE ALUMINUM WiTH 3 FOOT HIGH INTENSITY TYPE LINE CROSSING, LINE PARALLELING, OR PROPOSED CONNECTION 1500 W. 11TH AVENUE, SUITE 24 CITY OF ENCINITAS, STATE OF CALIFORNIA REFLECTIVE FACE OR EQUIVALENT. SMALL BE FIELD VERiFIED. ALL EXISTING OR PROPOSED UTILITY ESCONDIDO, CA 92029 APN# 256- 253 -06 CROSSINGS WITTHM 10 FEET of PROPOSED WATER MAINS SHALL BE SHOWN ON I � D SEWER TEL (760) 740 - 0885 IMPROVEMENT PLANS. ELECTRICAL �+ 15. CONTRACTOR SHALL REQUEST FROM THE CITY ENGINEERS OFFICE TO CROSS UNDER WATER MANS UNLESS GIVEN WRITTEN OWNERS CERTiFiVATE A PRECONSTRUCTiON MEETING AND SHALL PROVIDE AT LEAST 48 HOURS OF NOTICE FOR SUCH A MEETING. (633 - 2770) PERMISSION BY SAN DIEGUiTO W ATER DISTRICT PREPARED BY m I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST 16. ALL CUT AND FILL SLOPES OVER 3 FEET CREATED BY GRADING FOR 16.WATER CONNECTIONS TO COMMERCIAL DEVELOPMENTS SHALL SAN DIEGUITO ENGINEERING, INC. HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER ALL GRADING ACTIVITY STREETS AND DRIVEWAYS SHALL BE HYDRO SEEDED WITH CiTY OF HAVE AN APPROVED BACKFLOW DEVICE INSTALLED TO THE 4407 MANCHESTER AVENUE, SUITE 105 AND ADVISE ON THE COMPACTION AND STABILITY OF THE SITE. ENCINITAS APPROVED HYDROSEED MIXTURE. DISTRICT'S SATISFACTION. BACKFLOW DEVICES ARE TO BE ENCINITAS, CA 92024 HYDRO SEEDED SLOPED SHALL BE IRRIGATED BY WATER TRUCK INSTALLED DIRECTLY OUTSIDE CiTY OF COUNTY RIGHT- TEL: (760) 753 -5525 SIGNAT�=N ��Z=TEPHE7NS DATE: , � � W _ 1^ +� UNTIL THE MIXTURE GERMINATES AND GROWTH IS ESTABLISHED. OR OUTSIDE WATER DISTRICT EASEMENT. REPAIR MAINTENANCE AND ANNUAL TESTING OF BACKFLOW DEVICE ARE 17. ALL LUMINAIRES SHALL PROVIDE TRUE 90 DEGREES CUTOFF, AND RESPONSIBILITY OF OWNER. ALLOW NO ESCAPE OF LIGHT ABOVE HORIZONTAL (� 17. MINIMUM HORIZONTAL SEPARATION OF 10 FEET REQUIRED OWNER: KEVIN F. STEPHENS Z ADDRESS: 1500 W. 11TH AVENUE. SUITE 24 18. CONCENTRATED FLOWS ACROSS DRIVEWAYS AND /OR SIDEWALKS BETWEEN FIRE HYDRANTS AND SAN DIEGO GAS AND ELECTRIC _ SHALL NOT BE PERMITTED. DRAINAGE SHALL BE TRANSMITTED UNDER VAULTS. ESCONDIDO, CA 92029 SIDEWALK, THROUGH FACE OF CURB, TO GUTTER IN PUBLIC STREET. PHONE: TEL: (760) 740 - 0885 •► 19. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR 18. DES TO WATER MA INTAIN M 5 FOOT SEPARATION WHEN DECLARATION OF RESPONSIBLE CHARGE Z_ BENCH MARK WHiCH IS DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR 19.CONTRACTOR AND DEVELOPER ARE RESPONSIBLE TO RELOCATE I HEREBY DECLARE THAT 1 AM THE ENGINEER OF WORK FOR THIS PROJECT. IT IS AGREED THAT FIELD CONDITIONS MAY REQUIRE CHANGES TO THESE w A LICENSED LAND SURVEYOR ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PLANS. W 20. THE DEVELOPER SHALL MARK THE LOCATION OF EACH SEWER LATERAL VALVES, VALVE BOXES, ETC.) THAT ARE EFFECTED BY THEIR PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS ESS / , W AND WATER SERVICE BY CHISELING THE LETTERS "S" AND "W ", PROJECT. CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. �N R F IT IS FURTHER AGREED THAT THE OWNER (DEVELOPER) SHALL HAVE A Z RESPECTIVELY 2 INCHES HIGH INTO THE FACE OF THE CURB. y �� ° e REGISTERED CIVIL ENGINEER MAKE SUCH CHANGES, ALTERATIONS, OR I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS ADDITIONS TO THESE PLANS WHICH THE DIRECTOR OF ENGINEERING C7 21. THE ADDRESS OF EACH LOT SHALL BE PAINTED ON THE CURB IN A 20. CONTRACTOR T SUPPLY DOCUMENTATION SHOWING THAT ANY BY THE CITY OF ENCINITAS IS CONFINED TO A REVIEW ONLY AND DOES °A DETERMINES ARE NECESSARY AND DESIRABLE FOR THE PROPER Z MANNER AND LOCATION APPROVED BY THE INSPECTOR. ASBESTOS WATER PIPES REMOVED FROM THE GROUND WEE 13Y RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR NO. W44 COMPLETION OF THE IMPROVEMENTS. W DISPOSED OF IN A MANNER ACCEPTABLE TO THE SAN DIEGO PROJECT DESIGN �, EOM. 3-31-01 COUNTY WASTE DIVISION. 22. ALL WORK SHALL BE DONE IN ACCORDANCE WiTH THE STANDARD `� �r<`' Ct r r � o�� I FURTHER AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS SHOWN SPECIFICATION FOR THE PUBLIC WORKS CONSTRUCTION (LATEST i''`ce of cKuk ON THESE PLANS WITHIN EXISTING CITY RIGHT -OF -WAY WITHIN 60 0 EDITION). THE SAN DIEGO STANDARD SPECIAL PROVISIONS TO THE SAN DIEGUITO ENGINEERING, INC. LNG DAYS AFTER THE ISSUANCE OF THE CONSTRUCTION PERMIT AND TO STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 4407 MANCHESTER AVENUE, SUITE 105 IVAN R. FOX RICE 38144 _ N (ADOPTED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE), AND - ENCINITAS, CALIFORNIA 92024 PURSUE SUCH WORK ACTIVELY ON EVERY NORMAL WORKING DAY UNTIL =) to THE SAN DIEGO REGIONAL STANDARD DRAWINGS (LATEST EDITION) PHONE: (760)753 -5525 Z COMPLETED, IRRESPECTIVE AND INDEPENDENT OF ANY OTHER WORK ��� ' ASSOCIATED WITH THIS PROJECT OR UNDER MY CONTROL. W DATE SIGNATURE DATE: / - 14 - 'A •� M SAN DIEGUITO ENGINEERING INC. SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT SEWER AGENCY « „ nder round Service Alert KEVIN F. STEPHENS L0 LEUCADIA COUNTY WATER DISTRICT AS BUILT Z r*. 4407 MANCHESTER, SUITE 105 1 1 PUBLIC SEWER SYSTEM APPROVAL I Coll: TOLL FREE < ENCINITAS CA 92024 APPROVED BY: DUDEK AND ASSOCIATES, INC. e'f OWNER: KEVIN F. STEPHENS V) O PHONE: (760) 753 -5525 i/�j DA 422 ADDRESS: L O W. I1TH 9VENU�E, SUiTE 24 CIVIL ENGINEERING • PLANNING BY : ��-- 3 31 coo Bar /y�(�}'l� DA -9- � i • -sr 1919 -32 RICE: t/'� -� DIP: �/ � PHONE: TEL;- (7so) 740 -0885 � LAND SURVEYING SIGNATURE EXPIRES 2 YRS FROM DATE C 26514 DATE JOB NUMBER TMiO woRKn�G YOU DIG A f REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE SPECIAL DISTRICT DESIGNED BY 71 DRAWN M7= CHECKED APPROVALS CITY O F' ENCINITAS ENGINEERING DEPARTMENT DRAWING NO. rc I CHANGE CU RB QUIT rR 1 1 4100 DESCRIPTION: SD. CO. STD. DISC STAMPED PLANS PREPARED UNDER THE SUPERVISION OF RECOMMENDED APPROVED IMPROVEMENT PLANS FOR: AND s +vf- u whc - FO OC. 173,1969 _ LOCATION: 1 -5 & LEUCADIA BLVD. BRIDGE HORIZONTAL N A APPROVED B N ROLLED cu iZ� ��' NO. 57 -554. MON SET IN CONIC X 1 . eY: BY: HYG E I A AVENUE 5 851 - 1 8 ELO A u OUTLET SIDEWALK O S.E. CDR. OF BRIDGE / R.C.E. NO. . , 38 ' )15 -80 I. r , I . a RECORD FROM: SO. CO. VERT. CONTROL VERTICAL N/A �i A IVAN R. FOX EXP 3- 3/- O/ DATE: 4 - 6 -1-65 WORK PROJECT NO. TM 98 - 100 ELEV.= 174.529 SET 1 OF 2 WGEIA- SHT1kDWG, SCALE: 1* =1', DATE: 12 -15 -99 FLE NO. 4868 NoText