2004-9064 I (Plans) SAN DIEGUITO ACADEMY MODERNIZATION RECYCLED WATER STANDARD PLAN NOTES
SDWD WATER NOTES FOR IMPROVEMENT PLANS GENERAL IMPROVEMENT NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE SAN ELIJO
JOINT POWERS AUTHORITY. BL VD.
2. DRINKING WATER FOUNTAINS AND DESIGNATE
D OUTDOOR EATING AREAS SHALL BE
PROTECTED AGAINST
OR RUNOFF.
. '
1. WATER MAINS, LATERALS AND APPURTENANCES SHALL BE CONSTRUCTED ACCORDING TO THE STANDARD 1. A PERMIT SHALL BE OBTAINED FROM THE ENCINITAS ENGINEERING
SERVICES DEPARTMENT FOR ANY CONTACT WITH RECYCLED WATER SPRAY,
SPECIFICATIONS OF THE CURRENT WATER AGENCIES' STANDARDS COMMITTEE (WASP). THE CONTRACTOR WORK WITHIN THE STREET RIGHT -OF -WAY.
SHALL AND HEREBY DOES GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTE R THE DATE OF 3. BEST MANAGEMENT PRACTICES SHALL BE USED
TO ELIMINATE OR CONTROL TO THE BEST EXTENT z
ACCEPTANCE.
P
2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH CITY OF ENCINITAS PUBLIC ROAD POSSIBLE PENDING, RUNOFF, OVERSPRAY AND MISTING.
- 521
STANDARDS. R VALUE TESTS SHALL BE REQUIRED PRIOR TO CONSTRUCTION. NS
2. UNLESS OTHERWISE NOTED, ALL CONNECTIONS TO EXISTING MAINS WILL BE MADE BY THE CONTRACTOR, 4. HOSE BIBS ARE STRICTLY PROHIBITED.
UNDER THE SUPERVISION
e+
F 3. APPROV
0 SAN DIEGUITO WATER DISTRICT AFTER PA AL OF THESE IMPROVEMENT PLANS AS SHOWN DO T
PAYMENT OF THE ESTIMATED COST BY ES NO CONSTITUTE APPROVAL OF ANY
THE DEVELOPER. CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY. 5. CROSS - CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER
LINES ARE STRICTLY PROJECT
PROHIBITED.
LOCATION 4�
4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL BE CONSTRUCTED, s
3. WHERE ELEVATIONS AND GRADES ARE NOT SHOWN ON THE WATER MAIN PROFILE, TOP OF PIPE CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER
AND PAVING. APPROVAL OF THE SAN ELIJO SANT
PROFILE IS 48 INCHES BELOW CENTERLINE FINISH GRADE OF STREET. 6. NO SUBSTITUTIONS OF PIPE MATERIALS WILL BE ALLOWED WITHOUT PRIOR
APPROVA POWERS AUTHORITY.
4. ALL SERVICES TO BE CONSTRUCTED CLEAR OF DRIVEWAYS. �,
5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE �.
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE E N C I N I S
NO OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER THE COWRACTOR IS 7. ALL MAINLINE PIPES SHALL HAVE WARNING TAPE
PER SAN ELIJO JOINT POWERS AUTHORITY'S RULES
5. CONTRACTOR TO FURNISH ONE INCH COPPER WATER SERVICE AND METER BOX FOR EACH RESIDENTIAL REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING
FACILITY SHOWN HEREON AND AND REGULATIONS. s9
��
LOT. ANY OTHER WHICH IS NOT OF RECORD OR NOT SHOWN ON THESE PLANS.
8. HOURS FOR IRRIGATION WITH RECYCLED WATER ARE FROM 10:00 P.M. TO 6:00 A.M. THE HOURS FOR COVE
6. CONTRACTORS SHALL ACQUIRE A TRENCHING PERMIT FROM THE CALIFORNIA DIVISION OF SAFETY FOR 6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK
TO BE DONE SHALL BE IRRIGATION WITH DISINFECTED TERTIARY RECYCLED WATER MAY BE MODIFIED BY THE LOCAL AUTHORITY.
ALL TRENCH WORK. CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. CONTRACTOR WILL MAKE IRRIGATION DURING PUBLIC USE
PERIODS WITH DISINFECTED TERTIARY RECYCLED WATER SHALL BE UNDER rn
P T
EX LORA ORY EXCAVATIONS CA ONS AND LOCATE EXISTING TH �
UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF E SUPERVISION OF THE DESIGNATED USER SUPERVISOR. IRRIGATION WITH WATER OF A LESSER
QUALITY 5
7. INSTALL FIRE HYDRANTS 2.5 FEET FROM FACE OF CURB IF NO SIDEWALK EXISTS OR 7 CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF R
z
h
FACE OF CURB WHERE SIDEWALK EXISTS OR WILL BE CONSTRUCTED. �� FROM LOCATION OF EXISTING FACILITIES. REVISIONS ARE NECESSARY BECAUSE OF ACTUAL T
DISINFECTED TERTIARY RECYCLED WATER SHALL BE BETWEEN THE HOURS OF 10:00 P.M. AND 6:00
M.
8. PROVIDE AIR RELEASE ASSEMBLIES AT ALL HIGH POINTS IN WATER MAIN. 7. THE CONTRACTOR SHALL NOTIFY SAN DIEGO GAS D ELECTRIC COMPANY PRIOR
TO STARTING WORK 9. BURIAL OF ALL WIRING AND PIPING SHALL MEET SAN EUJO JOINT POWERS AUTHORITY'S RULES AND SAN
NEAR COMPANY FACILITIES AND SHALL COORDINATE HIS/HER WORK WITH COMPANY REPRESENTATIVES. REGULATIONS. Eu,a
9. CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT FROM THE CITY OF ENCINITAS FOR ANY ��; ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE
"UNDERGROUND INSTALLATIONS ".
EXCAVATION WITHIN EXISTING CITY RIGHTS -OF -WAY. 10. NON- DESIGNATED USE AREAS SHALL BE PROTECTED FROM CONTACT WITH RECYCLED WATER,
WHETHER
FOR LOCATION OF ELECTRICAL CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE SAN DIEGO 13Y WINDBLOWN SPRAY OR BY DIRECT APPLICATION
THROUGH I
GAS do ELECTRIC COMPANY. G IRRIGATION OR OTHER USE. LACK OF
10. THE DISTRICT REQUIRES THAT COMPACTION TESTS BE TAKEN WHERE WATER LINES ARE INSTALLED TELEPHONE: (800) 422 -4133 PROTECTION, WHETHER BY
DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION, IS STRICTLY
WITHIN EXISTING COUNTY RIGHTS-OF-WAY, CITY OF -
ENCINITAS RIGHTS F
0 WAY OR PRIVATE EASEMENT
PROHIBITED.
AND THE RESULTS APPROVED BY THE CITY OF ENCINITAS, BEFORE THE WATER LINES ARE ACCEPTED AND 8. THE CONTRACTOR SHALL NOTIFY PACIFIC BELL PRIOR TO STARTING
WORK NEAR COMPANY FACILITIES
I NA
HALL COORDINATE HI _ V ICINITY
TE S /HER WORK WITH COMPANY REPRESENTATIVES. 11. IRRIGATION HEADS SHALL BE RELOCATED OR ADJUSTED TO MINIMIZE OR ELIMINATE OVER
SPRAYING ON MAP
P
A COPY SENT TO THE SAN DIEGUITO WATER DISTRICT OFFICE. ANDS
- DESIGNATED USE AREAS.
11. PRIOR TO AWARDING WATER LINE CONTRACT OWNER
, SHALL ADVISE PROSPECTIVE CONTRACTORS SIDEWALKS, STREETS AND NON TO NOTICE: ALL TELEPHONE SERVICES WITHIN THIS PROJECT BOUNDARY
ARE "UNDERGROUND INSTALLATIONS" NO SCALE
OBTAIN AND REVIEW CURRENT WATER AGENCIES STANDARDS COMMITTEE WASP SPECIFl 11 FOR
( CA OHS. LOCATION OF CABLES AND APPURTENANCES CONTACT PACIFIC C C BELL.
TELEPHONE: (800) 422 -4133 12. RECYCLED WATER QUICK COUPLING VALVES SHALL BE OF A TYPE DESIGNATED FOR THE USE ON
12. THE CONTRACTOR SHALL NOTIFY THE DISTRICT'S INSPECTION DEPARTMENT 48 HOURS IN ADVANCE OF R
BEGINNING WORK TO ARRANGE FOR INSPECTION OF PROJECT. 9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTACT THE UTILITY AGENCIES, ADVISE
E WATER DISTRIBUTION SYSTEMS PER SAN ELIJO JOINT POWERS AUTHORITY'S RULES AND
REGULATIONS.
THEM OF THE PROPOSED IMPROVEMENTS, AND BEAR THE COST OF RELOCATIONS, IF NEEDED. 1.E�E�lQ
13. FILL AREAS MUST BE COMPACTED TO 90X, PRIOR TO PIPE INSTALLATION. 13. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER
HEADS, VALVE BOXES, ETC.) SHALL EXISTING CONTOUR
10. ALL TELEVISION SERVICES WITHIN THIS R ECT ARE "UNDERGROUND INSTALLATIONS FOR LOCATION _
BE COLOR - CODED PURPLE PER AWWA GUIDELINES AND SECTION 116815 OF THE CALIFORNIA HEALTH AND
14. APPROVAL OF THIS PLAN BY SAN DIEGUffO WATER DISTRICT DOES NOT CONSTITUTE A REPRESENTATION OF CABLES AND APPURTENANCES CONTACT IP800� 422 -4133. SAFETY
CODE. - - -. -
AS TO THE ACCURACY OF, THE LOTION OF, OR THE EXISTENCE OR NON- EXISTENCE OF, ANY
11 POWER SOURCES AND RUNS SERVING T EXISTING CURB & GUTTER - -
. STREET LIGHTS SHALL BE SHOWN ON THE "AS BUILT"
I ,UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS OF THIS PROJECT. 14. ALL IRRIGATION PIPES SHALL BE STENCILED WITH
THE WARNING "NON - POTABLE OR RECYC
EXISTING SIDEWALK L
IMPROVEMENT DRAWINGS. ALL SOURCES SHALL BE LOCATED WITHIN THE DEDICATED RIGHT -OF -WAY, OR (�
15. ALL EXISTING FACILITIES WHICH MAY EFFECT FINAL DESIGN, I.E., LINE CROSSINGS, LINE PARALLELING, WITHIN EASEMENTS DEDICATED TO THE CITY OF ENCINITAS.
WATERJ COLOR -CODED PURPLE AND LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE
OR TOP OF THE TRENCH PER THE SAN ELIJO JOINT POWERS AUTHORITY'S RULES AND REGULATIONS. 2' WATER SERVICE
PR OPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING OR PROPOSED UTILITY CROSSINGS 12. NO PAVING SHALL BE DONE UNTIL EXISTING POWER POLES ARE
RELOCATED OUTSIDE THE AREAS TO WS -08 W
WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL BE SHOWN ON IMPROVEMENT PLANS. ELECTRICAL AND BE PAVED. ABANDONMENT
15 ON NEW ON -SITE (POST - METER) POTABLE WATER, CONSTANT PRESSURE RECYCLED WATER
SEWER TO CROSS UNDER WATER MAINS UNLESS GIVEN WRITTEN PERMISSION B . Y SAN DIEGUITO WATER AND SEWER LINES
SHOULD BE PLACED A MINIMUM OF FOUR FEET APART OR AS DIRECTED BY THE 6' FIRE HYDRANT ;
DISTRICT. 13. PRIVATE ROAD IMPROVEMENTS SHOWN HEREON ARE FOR INFORMATION ONLY. CITY OFFICIALS WF -01, WF
-04 F-�- -�
PROJECT ENGINEER AND OR REGULATORY AGENCY. MEASUREMENTS SHALL BE BETWEEN FACING INSTALLATION SIGNATURE HEREON DOES NOT
CONSTITUTE APPROVAL 0 RESPONSIBILITY OF ANY KIND FOR THE DESIGN SURFACES, NOT PIPE CENTER LINES. � WT -01, WM -04
AP
16. WATER CONNECTIONS TO COMMERCIAL DEVELOPMENTS SHALL HAVE AN PROVED BACKFLOW DEVICE OR CONSTRUCTION OF THESE PRIVATE IMPROVEMENTS. (IF APPLICABLE).
INSTALLED TO THE DISTRICTS SATISFACTION AND CURRENT WATER AGENCIES STANDARDS COMMITTEE 14, ALL LUMINAIRES SHALL PROMDE TRUE 90' CUTOFF, AND ALLOW
NO ESCAPE OF LIGHT ABOVE THE 16. CONSTANT PRESSURE RECYCLED WATER LINES SHALL CROSS AT LEAST TWELVE INCHES BELOW AND I I
(WASC) STANDARDS, BACKFLOW DEVICES ARE TO BE INSTALLED DIRECTLY OUTSIDE CITY OF COUNTY
RIGHT-OF-WAY OR OUTSIDE WATER DISTRICT EASEMENT. REPAIR, MAINTENANCE AND ANNUAL TESTING OF HORIZONTAL POTABLE WATER LINES AND MAINTAIN AT
LEAST TWELVE INCHES CROSSING SEPARATION BETWEEN OTHER WT-01 E
BACKFLOW DEVICE ARE RESPONSIBILITY OF OWNER.
UTILITIES. FIRE SERVICE I
15. THE CONTRACTOR SHALL REQUEST FROM THE ENGINEERING SERVICES DEPARTMENT A
17. MINIMUM HORIZONTAL SEPARATION OF 10 FEET REQUIRED BETWEEN FIRE HYDRANTS AND SAN DIEGO PRE - CONSTRUCTION MEETING AND SHALL PROVIDE AT LEAST 48 HOURS
OF NOTICE FOR SUCH A MEETING. 17. IF A CONSTANT PRESSURE RECYCLED WATER LINE MUST BE INSTALLED ABOVE A POTABLE WATER LINE
GAS AND ELECTRIC VAULTS. PHONE NUMBER 633 -2770. OR LESS THAN TWELVE INCHES BELOW A POTABLE WATER LINE, THEN THE RECYCLED
WATER LINE SHALL 2' PVC WATER SERVICE WS MR--01 W
BE INSTALLED WITHIN AN APPROVED PROTECTIVE SLEEVE AS PER THE SAN ELIJO JOINT POWERS
18. UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER SERVICES. 16. THE DEVELOPER SHALL BE RESPONSIBLE THAT ANY MONUMENT OR
BENCH MARK WHICH IS AUTHORITY'S RULES AND REGULATIONS. FIRE SERVICE I
DISTURBED OR DESTROYED SHALL BE RE- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER
19. CONTRACTOR AND DEVELOPER ARE RESPONSIBLE TO RELOCATE ANY EXISTING WATER FACILITY (FIRE CHISELING THE LETTERS S AND � , OR A LICENSED LAND SURVEYOR.
RESPECTIVELY, 2 INCHES HIGH INTO THE FACE OF THE CURB. 18. DEVELOPER/CONTRACTOR SHALL CONDUCT A CROSS - CONNECTION TEST AND COVERAGE TEST AS W-01,
CA1E yE
HYDRANT, METERS, VALVES, VALVE BOXES, ETC.) THAT ARE EFFECTED BY THEIR PROJECT. 17. THE DEVELOPER SHE MAR TrE LOCATION OF EACH SEWER LATERAL
AND WATER SERVICE BY ENVIRONMEN DIRECTED BY TTHH TAL HEALTH PRIOR TO ANY USE OF RECYCLED WATER. E SAN ELUO JOINT POWERS AUTHORITY AND /OR THE SAN DIEGO COUNTY
DEPARTMENT OF W V- 04 , VT, WV WV-03 MI GIV
20. CONTRACTOR TO SUPPLY DOCUMENTATION SHOWING THAT ANY ASBESTOS WATER PIPES REMOVED FROM
THE GROUND WERE DISPOSED OF IN A MANNER ACCEPTABLE TO THE SAN DIEGO COUNTY WASTE DID\ 18. THE ADDRESS OF EACH LOT SHALL BE PAINTED ON THE CURB
IN A MANNER AND LOCATION 19. THE REQUIRED CROSS - CONNECTION CONTROL SHUTDOWN TEST SHALL BE MONITORED BY EITHER THE STORM DRAIN D D-61 SD
VISION. APPROVED BY THE INSPECTOR. SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH OR STATE HEALTH.
21. USE THE FOLLOWING VATS COMBINATIONS OF PLAIN END PIPE LENGTHS WITH Him DEFLECTION A1-1K G -7
I
19. ALL WORK SHALL E DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC 20. THE DESIGN AND LOCATIONS PROPOSED FOR
RECYCLED WATER b0 NOT DRINK SIGNS SHALL BE
COUPLINGS AND INTEGRAL BELL END PIPE FOR CURVED ALIGNMENTS IN BOTH HORIZONTAL AND VERTICAL WORKS CONSTRUCTION LATEST EDITION), THE SAN DIEGO STANDARD
SPECIAL PROVISIONS TO THE CALLED OUT ON THE PLANS.
BY THE SAN DIEGO Q S FOR PUBLIC WORKS CONSTRUCTION ADOPTED EGIONAL
DIRECTIONS. DO NOT BEND PIPE BETWEEN COUPLINGS. SAW CUT INTEGRAL BELL END OF STANDARD PIPE STANDARD SPECIFICATI
4' AC an 15' AGG. BASE
AND BEVEL END FOR USE WITH DEFLECTION COUPLINGS. USE 9.5 -FOOT PLAIN END PIPE LENGTHS WITH STANDARDS COMMITTEE), AND THE SAN DIEGO REGIONAL STANDARD
� D DRAWINGS (LATEST EDITION). 21. WHEN RECYCLED WATER BECOMES AVALABLE, AN ON -SITE USER SUPERVISOR SHALL BE DESIGNATED
DEFLECTION COUPLINGS FOR ALL RADII BETWEEN 140 FEET TO 270 FEET. USE 19 -FOOT PIPE LENGTH IN WRITING. THIS INDIVIDUAL SHALL BE
FAMILIAR WITH PLUMBING SYSTEMS, WITH THE PROPERTY, WITH g• FULL D AC REPAIR DETAIL SHEET 3
WITH DEFLECTION COUPLINGS FOR ALL RADII BETWEEN 270 FEET TO 560 FEET. USE AND INTEGRAL BELL YI1017K TO BE DONE THE BASIC CONCEPTS
OF BACKFLOW /CROSS - CONNECTION PROTECTION, THE RECYCLED PURVEYORS , RULES
END PIPE LENGTH JOINED TOGETHER WITH A 19 -FOOT PLAIN END PIPE LENGTH TO FORM A CHORD. USE AND REGULATIONS AND THE SPECIFIC REQUIREMENTS
OF A RECYCLED WATER SYSTEM. COPIES OF THE
DEFLECTION COUPLINGS ON EACH END OF THE CHORD AND CONTINUE THIS COMBINATION THROUGH THE THE IMPROVEMENTS CONSIST OF THE FOLLOWti<IG WORK TO BE DONE
ACCORDING DESIGNATION, WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE SAN ELUO JOINT POWERS
CURVED ALIGNMENT FOR ALL RADII BETWEEN 560 FEET TO 1,150 FEET. PIPE LENGTHS SHORTER THAT 9 ACCORDING TO THESE PLANS AND THE SPECIFICATIONS AND STANDARD
DRAWINGS AUTHORITY AND /OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. TRENCH BEDDING, BACKFILL
FEET WILL NOT BE USED UNLESS SPECIFICALLY AUTHORIZED THE BY T�fE DISTRICT'S REPRESENTATIVE. OF THE CITY OF ENCINITAS, AND THE SAN DIEGUITO WATER DISTRICT.
AND CAP PER CITY OF
ENCINITAS STANDARD DRAWING.
STATEMENT OF ENGINEER O' WORK STANDARD SPECIFICATIONS IN CASE OF EMERGENCY CONTACT NAME AT PHONE NUMBER PEDESTRIAN RAMP
-
G 31
THE UNDERSIGNED ENGINEER AGREES THAT THE WORK PERFORMED BY THE ENGINEER SHALL COMPLY 1. STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (2000
CURB do GUTTER (TYPE 'G') G -2
WITH THE GENERALLY ACCEPTED STANDARDS AND PRACTICES OF THE ENGINEERS TRADE OR PROFESSION. EDITION), INCLUDING THE REGIONAL AND CITY OF SAN DIEGO
OR AFTER HOURS CONTACT AT
THE ENGINEER FURTHER AGREES THAT THE WORK PERFORMED HEREIN SHALL BE IN ACCORDANCE WITH SUPPLEMENT AMENDMENTS, DOCUMENT NO. 769845, FILED JULY 21,
2000. NAME PHONE NUMBER 6" AC BERM
THE RULES AND REGULATIONS REQUIRED BY THE CITY OF ENCINITAS, SAN DIEGUITO WATER DISTRICT, SAN G -5
ELUO JOINT POWER AUTHORITY, AND SAN DIEGO COUNTY ENVIRONMENTAL HEALTH IN ITS CAPACITY AS A 2. CALIFORNIA DEPARTMENT OF TRANSPORTATION, 'MANUAL OF TRAFFIC
PUBLIC ENTITY FOR THE PLANS OR DESIGN, AND IT THEREFORE DOES NOT RELIEVE THE ENGINEER OF CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES," (1996
22. ALL PUBLIC AND PRIVATE POTABLE WATER MAINS INCLUDING FIRE MAINS AND ANY WATER WELLS AND
RESPONSIBILITY FOR THE PLANS OR DESIGN OF IMPROVEMENTS BASED THEREON. THE ENGINEER AGREES EDITION), DOCUMENT NO. 769843, FILED JANUARY 24, 2000.
WATER COURSE WITH THE RECYCLED WATER PROJECT SHALL BE SHOWN ON THE PLANS. ABBREVIATIONS rr
TO INDEMNIFY AND HOLD HARMLESS THE CITY OF ENCINITAS, SAN DIEGUITO WATER DISTRICT, SAN ELIJO
JOINT POWER AUTHORITY, AND SAN DIEGO COUNTY ENVIRONMENTAL HEALTH AND ITS OFFICERS AGENTS 3. WATER AGENCIES STANDARDS DECEMBER 31 2003
AND EMPLOYEES FROM PROPERTY DAMAGE OR BODILY INJURY ARISING SOLELY FROM THE NEGLIGENT � 23. CALL OUT ON THE PLANS IF THERE ARE
OR ARE NOT DRINKING FOUNTAINS AND /OR DESIGNATED AC ASPHALT CONCRETE PP POWER POLE
ACTS, ERRORS, OR OMISSIONS OF THE ENGINEER AND HIS /HER AGENTS OR EMPLOYEES ACTING WITHIN STANDARD DRAWINGS OUTDOOR EATING AREAS ON THIS
SITE.
AD A�.SBESTOS CEMENT PIPE R PVC C� L A O�RIR E PIPE
THE COURSE AND SCOPE OF SUCH AGENCY AND EMPLOYMENT AND ARISING OUT OF THE WORK
PERFORMED BY THE ENGINEER. I. CITY OF SAN DIEGO STANDARD DRAWINGS, DOCUMENT NO. 769846, FILED 24. EDUCATE ALL MAINTENANCE PERSONNEL
ON A CONTINUOUS BASIS OF THE PRESENCE OF RECYCLED AVE AVENUE R.P.B.P. REDUCED PRESSURE OACK FLOW PREVENTER
JULY 21, 2000 WATER. PERSONNEL MUST BE INFORMED THAT RECYCLED WATER IS MEANT FOR IRRIGATION PURPOSES BLDG BUILDING
S SEWER
Q AtOFES.S /q ONLY, AND IS NOT APPROVED FOR DRINKING PURPOSES, HAND WASHING, CLEANING OF TOOLS, ETC. CENTER LINE
SCO SEWER CLEANOUT
7 2. WATER AGENCIES STANDARDS, DECEMBER 31, 2003 GIVEN THE HIGH TURNOVER RATE OF EMPLOYEES IN THE LANDSCAPE INDUSTRY IT IS
IMPORTANT THIS ONC CONCRETE SD STORM DRAIN
B 5 S Engineering, Inc. �� A l E ELECTRICAL S.D.R.S.D. SAN DIEGO REGIONAL STANDARD DRMAG
� � � INFORMATION BE DISSEMINATED ON AN ALMOST DAILY BASIS.
6859 Federal Boulevard 4, `� y ELECT ELECTRICAL SQ SQUARE
Lemon Grove, California 91945 y = = SHEET INDEX 25. A PHYSICAL SEPARATION SHALL BE PROVIDED BETWEEN ADJACENT AREAS IRRIGATED
WITH RECYCLED FD FOUND T TELEPHONE
(619) 582 -4992 FAX (619) 582 -7428 c� rn FF FINISHED FLOOR TC TOP OF CURB
oc 34867 DWG TITLE SHEET N0. WATER AND POTABLE WATER. SEPARATION SHALL BE PROVIDED BY DISTANCE, CONCRETE MOW STRIPS OR
OTHER APPROVED METHODS. FH FIRE HYDRANT TOP OF FOOTING
FL F LOW LINE OP OF GRATE
A4cnwk� �} crvt�- SHT 1 TITLE SHEET 1 FS FIRE SERVICE TRANS TRANSFORMER
7� - 26. THERE SHALL BE NO DIRECT (PIPE -TO -PIPE) DRAINAGE OF RECYCLED WATER INTO THE STORM FT FEET TW TOP
OF WALL
30 OF 0 DRAINS. G GAS TYP TYPICAL
- T HOMAS A. J RC 4867 DATE HB HOSE BIB W WATER
SHT_2 NARDO RD, MELBA RD, BONITA DR 2 27. ABSOLUTELY MINIMIZE BY BEST MANAGEMENT PRACTICES RECYCLED WATER RUNOFF TO STORM
DRAINS. HP HIGH PRESSURE W/ WITH
STREET IMPROVEMENTS OHE OVERHEAD ELECTRIC WM WATER METER
28. DESIGN OF BROW DITCHES AND CATCH BASINS SHALL ABSOLUTELY MINIMIZE RECYCLED WATER RUNOFF POC POINT OF CONNECTION
SHT_3 SANTA FE DR, NARDO RD, BONITA DR 3 INTO STORM DRAINS. ID
STREET IMPROVEMENTS 29. ALL RECYCLED WATER SPRINKLER CONTROL VALVES SHALL BE TAGGED WITH IDENTIFICATION TAGS.
TAGS SHALL BE WEATHERPROOF PLASTIC 3 X 4 PURPLE IN COLOR WITH WORDS "WARNING RECYCLED
WATER - DO NOT DRINK" IMPRINTED ON ONE SIDE, AND "AMSO - AGUA IMPURA - NO TOMAR" ON THE Engineering, Inc
L9 p fESS/
uraB�+ma J� Jller! SAN DIEGUITO WATER DISTRICT ENCINITAS FIRE DEPARTMENT SAN ELIJO JOINT POWER AUTHORITY ENVIRONMENTAL HEALTH OTHER
SIDE. IMPRINTING SHALL BE PERMANENT AND BLACK IN COLOR IB US Civil Eng ine e ring
v,
COUNTY OF SAN DIEGO � 'i
Land Surve h
M�ww REVIEWED BY: REVIEWED BY: REVIEWED DEPARTMENT OF ENVIRONMENTAL HEALTH ONE TAG SHALL BE ATTACHED TO EACH VALVE AS FOLLOWS:
6859 Federal Boulevard � n$
LAND USE DIVISION
NoText
NoText