2003-1381 G (Plans)NoText
NoText
NoText
FORRADNO NOTES (c oNTINuED) F . SAN DIEGUITO WATER DISTRICT NOTES
1- 112" CRUSHED FILTER
ORIGINAL
1) REVIEW OF THIS PLAN BY SAN DIEGUITO WATER DISTRICT DOES NOT CONSTITUTE A ROCK FABRIC
E. STORM WA TER POLLUTION CONTROL BMP NOTES REPRESENTATION AS TO THE ACCURACY OF, THE LOCATION OF, OR THE EXISTENCE OR
GRADE
RELATIVE TO CONSTRUCTION ACTIVI TIES NONEXISTENCE OF, ANY UNDERGROUND UTILITY, PIPE OR STRUCTURE WITHIN THE LIMITS
,. .
OF THIS PROJECT. _
- CONCRETE WASHOUT
2) ALL EXISTING FACILITIES WHICH MAY AFFECT FINAL DESIGN, I.E., LINE CROSSINGS,
CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE WASHOUT LINE PARALLELING, OR PROPOSED CONNECTION SHALL BE FIELD VERIFIED. ALL EXISTING
3 MIN UNLESS OTHERWISE
SP
AREA TO CONTAIN WASHOUT WASTES ON SITE IT IS ILLEGAL TO WASH CONCRETE, OR PROPOSED UTILITY CROSSINGS WITHIN 10 FEET OF PROPOSED WATER MAINS SHALL
SPFIED BY SOILS ENGINEER
SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORM WATER BE SHOWN ON IMPROVEMENT PLANS. ELECTRIC AND SEWER TO CROSS UNDER WATER 1
1't SEC77ON A -A
CONVEYANCE SYSTEM OR ANY RECEIVING WATER. CONTRACTOR SHALL POST A SIGN MAINS UNLESS GIVEN WRITTEN PERMISSION BY SAN DIEGUITO WATER DISTRICT.
DESIGNATING THE WASHOUT LOCATION.
3) CONTRACTOR AND OWNER ARE RESPONSIBLE TO RELOCATE AND /OR ADJUST TO 000800 0 o A
GRADE ANY EXISTING WATER FACILITY (FIRE HYDRANT, METERS, VALVES, VALVE BOXES, 000000
- CONSTRUCTION SITE ACCESS ETC.) WHICH IS AFFECTED BY THEIR PROJECT. ALL AFFECTED WATER FACILITIES MUST � 0000000
°00000 °0 ° 0 0 0 0 0 0 0 0 0 0 0 0
MEET CURRENT SAN DIEGUITO WATER DISTRICT STANDARDS � IF FACILITIES DO NOT MEET 000000000000000000
0000000000000 0 0 0
STANDARDS, THEN THEY SHALL BE UPGRADED TO CURRENT STANDARDS AT THE 0 0 0
A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS 0 0 0 0 0 0 0 0 °0 °0 ° 0 ° 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
AND INGRESS TO PREVENT TRACKING DIRT OFF SITE OWNER S EXPENSE. THIS SHALL INCLUDE USING 0 0 0 0 0 0
0 0 0 0 0 0 0 0000 0 0 0 0 ° 0 ° 0 0 ° 0 0 ° 0 ° 0 ° 0 ° 0 ° 0 ° 0 °0 °0 °0°
MATERIAL SUCH AS GRAVEL AND / /P OR CORRUGATED STEEL PANELS LA TES. 20 00000000000000000 00000000000
0 0 0 0 0 0 0 0 0 0 0
°0 °0 ° 0 ° 0 ° 0 ° 0 ° 0 ° 0 ° 0 ° 0 16'
4) UTILITIES TO MAINTAIN MINIMUM 5 -FOOT SEPARATION WHEN PARALLELING WATER 0 0
CONSTRUCTION VEHICLES SERVICES. W O o ° o 0 ° °0 °0 °0 ° 0 ° 0 ° 0 ° 0 ° 0 ° 0 °0 °0 °0 °0 °0°
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
o 0
5 MINIMUM HORIZONTAL SEPARATION OF f0 FEEL REQUIRED BETWEEN FIRE HYDRANTS o° o° o° o °o °o ° o o ° 0 0 0 0 0 0
0 0 0000000000000 °
A SPECIFIC AREA AWAY FROM GUTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR cc 000000000000000000000000000000000
0 00000000000 0 0 0 0 ° 0 °0 °0 ° 0 ° 0 ° 0 ° 0 ° 0 °
CONSTRUCTION VEHICLES PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT AND SAN DIEGO GAS AND ELECTRIC VAULTS. 1%(
0 o 0
MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE. 0
6) ALL WATER SERVICES TO BE CONSTRUCTED CLEAR OF DRI VEWAYS AND ALL OTHER A
TRAVELED WAYS. WATER METERS MUST BE IN FRONT OF THE PARCEL THEY ARE •
— EROSION CONTROL SERVING. �°+ . 15' 24'
EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES SLOPED
SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING
EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND DETAIL 1 NOT TO SCALE
COVER VEGETATION, AND BONDED FIBER MATRIX.
NO EXCAVATION AND GRADING ACTIVITIES ARE ALLOWED DURING WET WEATHER STABILIZED CONSTRUCTION ENTRANCE
DI VERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE
CONSTRUCTION SITE CONTRACTOR SHALL PROTECT CHANNELS AGAINST EROSION USING
PERMANENT AND TEMPORARY EROSION CONTROL MEASURES.
REMOVE EXISTING ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS
SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL
GROUND COVER. DO NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP
DECREASE EROSION.
TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS
NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHALL BE
PREVENTED BY PLANTING FAST - GROWING ANNUAL AND PERENNIAL GRASSES TO SHIELD
AND BIND THE SOIL.
PLANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND
GRADING ACTIVITIES ARE COMPLETE
WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED.
ON —SITE CONSTRUCTION MATERIAL STORAGE
STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE
AND SPILLAGE CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY
DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR
ALL FUEL STORED ON -SITE.
ELIMINATE OR REDUCE POLLUTION OF STORM WATER FROM STOCKPILES KEPT ON -SITE.
STOCKPILES MAY INCLUDE SOIL, PARING MATERIALS, ASPHALT CONCRETE, AGGREGATE
BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORM WATER
FLOWS AND STORM DRAIN INLETS. STOCKPILES SHALL BE COVERED OR PROTECTED
WITH SOIL STABILIZATION MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT
BARRIER AROUND THE PERIMETER AT ALL TIMES.
.M
i
- TRAINING
CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS
SHALL BE TRAINED TO BE FAMILIAR WITH THE CITY OF ENCINITAS STORM WATER 10
POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAILABLE TO a
EVERYONE WORKING ON SITE THE PROPERTY OWNER(S) AND THE PRIME CONTRACTOR y •
MUST INFORM SUBCONTRACTORS ABOUT STORM WATER REQUIREMENTS AND THEIR OWN
RESPONSIBILITIES.
Y -+
a
- WASTE MANAGEMENT
CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE AND
UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON a
THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS
STRICTLY PROHIBITED. r.
0
NO SEEPAGE FROM DUMPSTERS SHALL BE DISCHARGED INTO STORM WATER. E•
BERMS/DIKES SHALL BE PLACED AROUND DUMPSTERS
TO DIVERT THE NATURAL STORM RUNOFF. DUMPSTERS SHALL BE CHECKED a
FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT ALL TIMES
DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS q � q
ROOFING OR COVERED WITH TARPS IN ORDER TO AVOID RAIN CONTACT WITH ANY L'o
TRASH MATERIAL. w
MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER -BASED PAINTS,
VEHICLE FLUIDS, BROKEN ASPHALT AND CONCRETE, WOOD, AND CLEARED VEGETATION U
CAN BE RECYCLED. NON - RECYCLABLE MATERIALS MUST BE TAKEN TO AN
APPROPRIA LANDFILL OR DISPOSED OF AS HAZARDOUS WASTE FOR INFORMATION ON QQ pF E SS /OH
DISPOSAL OF HAZARDOUS MATERIAL, CALL THE HAZARDOUS WASTE HOTLINE TOLL FREE 7
AT (800) 714 -1195. FOR INFORMATION ON LANDFILLS AND TO ORDER DUMPSTERS CALL ��`Z`� K ,o4s►!
EDCO AT (760) 436 -4151.
W � �
y � o �
POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES. PLACE TRASH CANS AND c� No 41022 m U
RECYCLING RECEPTACLES AROUND THE SITE. IRES
E� 3-31 -2007 *
PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR `!r CIVIL
LEAKS CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT AND LOCATE
PORTABLE TOILETS AWAY FROM STORM DRAIN INLETS ON PERVIOUS SURFACES. lF OF CA1. +o yy
Co c3
ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GUTTER, AND U
STORM DRAIN. CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT O
MAY HAVE TRAVELED AWAY FROM CONSTRUCTION SITE. m
ED BY BY DRAW CHEC
Y WN K �
REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE TN M DESIGNED B TN K APPROVALS CITY OF
ENCINITAS ENGINEERING DEPARTMENT DRAWING NO. �3
SHOULDER OF ARDEN DRIVE I L 3' *EST F HORIZONTAL: N/A PLANS PRE OSION OF RECOM APPRO GRADING PLAN FOR: —
1 381 -G
EP & APPROX. 60' SLY OF S'LY PL � BY / I/ I. �I/I BY. KNIPE RESIDENCE 03 017 MIN /CDP ELEV. 100.00
(ASSUMED) VERTICAL. N/A 609 ARDEN DRIVE APN 258 - 103 -08
ENGINEER OF WORK R.C.E. 41022 DATE: 112-31 0-a DATE: f �,�,
MICHAEL K. PASKO EXP. 313112007 T NOTES SHEET 4 OF 4 O
Dec 19, 2003 — 14: 43: 01 P: \03 -009 KNIPE \xrefs \03009GP1.DWG PLOT 0 1 =20