Loading...
1988 PLANS FOR THE CONSTRUCTION OF STORM DRAIN IMPROVEMENTS IN THE CITY OF ENCINITAS VULCAN AVENUE - CMD 99B SANTA FE DRIVE CMD 01B SHEET INDEX GENERAL NOTES SHEET 1 - TITLE SHEET 1. A NO FEE PERMIT SHALL BE OBTAINED FROM THE CITY OF ENCINITAS ENGINEERING DEPARTMENT FOR ANY WORK WITHIN THE STREET RIGHT-OF-WAY. SHEET 2 - VULCAN AVENUE STORM DRAIN AND PROFILE 2. THE STRUCTURAL SECTION SHALL BE AS SHOWN ON THESE PLANS. PLAN A SHEET 3 - SANTA N DRIVE STORM DRAIN 3. APPROVAL OF THESE IMPROVEMEN PLANS AS SHOWN DOES NOT CONSTITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY. PLAN AND PROFILE 4. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE. THERE ARE NO OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. HOWEVER. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING FACILITY SHOWN HEREON AND ANY WHICH IS NOT OF RECORD S11 LEGEND OR NOT SHOWN ON THESE PLANS. PROPOSED FEATURES 5 S HALL BEE CON RME ELEV . FIELD MEASUREMENTS PRIOR TO CONSTRUCTION OF NEW WORK. $r LEUCADIA CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS AND LOCATE ALL EXISTING UNDERGROUND o PROPOSED STORM DRAIN FACILITIES PRIOR TO THE START OF ANY WORK WHICH CROSS NEW STORM DRAIN PIPE BLVD. s SIZE AND TYPE AS NOTED PROPOSED BY THIS PROJECT. SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES. PROPOSED CURB INLET 6. A. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS & ELECTRIC COMPANY PRIOR TO TYPE "A" PER SDRSD D - 1 PROPOSED CURB INLET STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES y n � VISTA DEL REY TYPE 'B" PER SDRSD D -2 NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE UNDERGROUND INSTALLATIONS S21 CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE . FOR LOCATION OF ELECTRICAL n ENaN1� PS SAN DIEGO GAS do ELECTRIC COMPANY. C fOR TRAFFIC LOOP DETECTOR TELEPHONE: (800) 422 -4133 -. D STREET �y B NEAR�OMPANY�FACIUTiES N AND PA CIFIC COMPANY REPRESENTATi�TMG WORK LOCATIONS ENCINITAS ��ptij, PROPOSED CURB AND GUTTER TELEPHONE: (fi19) 546 -3'606 it: y� PER SDRSD G -2 C. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGUITO WATER DISTRICT PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE WITH COMPANY REPRESENTATIVES SANTA FE DR. R ! PROPOSED CURB PER SDRSD G - NOTICE: FOR THE LOCATION OF WATER DISTRICT FACILITIES WITHIN 1L� s�ti �O THE PROJECT AREA TELEPHONE: (760) 633 -2709. D. THE CONTRACTOR SHALL NOTIFY COX CABLE TELEVISION COMPANY PRIOR TO STARTING WORK S9 NEAR COMPANY FACILITIES AND SHALL COORDINATE WITH COMPANY � NOTICE: FOR LOCATION OF CABLES AND APPURTENANCES w CONTACT COX CABLE TELEVISION COMPANY. � . BIRMINGHAM J ��- ABBREVIATIONS TELEPHONE: (800) 422 -4133 DRIVE w �� 7. CONTRACTOR SHALL RELOCATE ALL INTERFERING TRAFFIC SIGNS AS DIRECTED BY THE CITY >ffi AC - ASPHALT CONCRETE BCR = BEGIN CURB RETURN INSPEC c Q� PVMT - PAVEMENT ECR - END CURB RETURN - PORTLAND CEMENT CONCRETE (72.89) - EXISTING ELEVATION & WORKS CONSTRUCTION D (LATEST EDITION). THE THE SAN DIEGO STANDARD SPECIAL PROVISION VICINITY MAP P� UP =GUTTER UP PCR =POINT OF REVERSED CURVE THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (ADOPTED BY THE SAN DIEGO X - GTR =CROSS GUTTER (R) - RADIAL BEARING THE SAN DIEGO REGIONAL STANDARD DRAWINGS (LATEST EDITION). NO SCALE EP = EDGE OF PAVEMENT VERT. = VERTICAL REGIONAL STANDARDS COMITTEE). WI TC = TOP OF CURB VE R . = HORIZONTAL AND THE SPECIAL PROVISIONS FOR THIS PROJECT. SAN FL - FLOWUNE SDRSD = SAN DIEGO REGIONAL INV - PIPE INVERT STANDARD DRAWINGS 9. ALL PRIVATE IMPROVEMENTS IN THE PUBLIC RIGHT -OF -WAY DESIGNATED TO BE REMOVED SHALL BE ELIJO TB - TOP OF BERM EXIST. = EXISTING SALVAGED AND RETURNED TO THE PROPERTY OWNER. ALL PRIVATE IMPROVEMENTS OUTSIDE THE A BC =BEGIN CURB READ. - REQUIRE PUBLIC RIGHT -OF -WAY DAMAGED BY THE CONSTRUCTION OF THE PROJECT SHALL BE REPAIRED BY S21 EC END CURVE PVC = POLYVINYL CHLORIDE PIPE THE CONTRACTOR. 10. THE CONTRACTOR SHALL PROTECT EXISTING LANDSCAPING AND IMPROVEMENTS REMAINING IN PLACE. :.> NO LANDSCAPING OR IMPROVEMENTS SHALL BE DAMAGE OR REMOVED WITHOUT PRIOR APPROVAL OF THE CiTY. 11. THE CONTRACTOR SHALL BE RESPONSIBLE THAT ANY MONUMENT OR BENCHMARK Mini IS DISTURBED TRAFFIC CONTROL N OR LICENSED SHALL BE �- ESTABLISHED AND REPLACED BY A REGISTERED CIVIL ENGINEER OR A LICENSED LAND SURVEYOR. 12. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL BE CONSTRUCTED. CONNECTED 1. TRAFFIC CONTROL SHALL BE IN ACCORDANCE WITH SECTION 7 -10 OF THE STANDARD AND TESTED PRIOR TO CONSTRUCTION OF BERM, CURB, CROSS GUTTER. AND PAVING. SPECIFICATIONS. SPECIAL PROVISIONS AND CALTRANS MANUAL OF TRAFFIC CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES (1985 EDITION). 13. THE CONTRACTOR SHALL REQUEST FROM THE CITY ENGINEER'S OFFICE A PRE- CONSTUCTiON MEETING AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE FOR SUCH A MEEETiNG. CALL 1- 760 - 633 -2770. 2. THE CONTRACTOR SHALL MAINTAIN TRAFFIC FLOW IN BOTH DIRECTIONS IN CONFORMANCE WITH CALTRANS STANDARD PLAN T -11. T -12 OF T -13 DURING THE WORKING HOURS OF 9:00 14. THE CONTRACTOR SHALL MAINTAIN ADEQUATE DUST CONTROL MEASURES THROUGHT THE DURATION OF AM TO 3:00 PM, MONDAY THROUGH FRIDAY. UNLESS OTHERWISE AUTHORIZE, NO WORK THAT PROJECT CONSTRUCTION. PROJECT SITE MAINTENANCE SHALL CONFORM TO SECTION 7 -8 OF THE OBSTRUCTS NORMAL TRAFFIC FLOW WILL BE ALLOWED DURING THE HOURS OF 3:00 PM TO STANDARD SPECIFICATIONS 9:00 AM AND AT ALL TIMES SATURDAYS. SUNDAYS AND LEGAL HOLIDAYS. WHEN CONSTRUCTION OPERATIONS ARE NOT ACTIVELY IN PROGRESS THE CONTRACTOR SHALL 15. THE CONTRACTOR SHALL MAINTAIN A SET OF 'AS -BUILT' DRAWINGS ON WHICH ALL CHANGES OR MAINTAIN ALL TRAVELED LANES OF THE ROADWAY. VARIATIONS IN THE WORK. INCLUDING UTRITiM ARE TO BE RECORDED. A COPY OF SAID 'AS- BUILT DRAWINGS SHALL BE PROVIDED TO THE CITY OF ENCINITAS WHEN REQUESTED. 3. ACCESS TO PRIVATE PROPERTY SHALL BE MAINTAINED AT ALL TIMES 16. MATERIAL OR DEBRIS SHALL NOT BE STORED OR REMAIN IN THE PUBLIC RIGHT-OF-WAY WITHOUT 4. ALL TRAVEL LANES WILL BE A MINIMUM OF 12' WiDE UNLESS OTHERWISE SHOWN. APPROVAL BY THE CITY ENGINEER. 5. PEDESTRIAN FLOW WALL NOT BE DISTURBED UNLESS OTHERWISE SHOWN. 17. OCCUPATIONAL SAFETY A: HEALTH ADMMISTRATiON (OSHA) NOTE: THE CONTRACTOR IS REQUIRE TO OBTAIN A PERMIT FROM OSHA PRIOR TO COMMENCING CONSTRUCTION OF TRENCHES OR EXCAVATIONS 6. TRENCH PLATES TO BE PROVIDED MATH SKID RESISTANT SURFACE. WHICH ARE 5 FEET OR DEEPER AND INTO WHICH A PERSON IS REQUIRED TO DECEND. 7. THE CONTRACTOR SHALL NOTIFY ALL ADJACENT PROPERTY OWNERS OF THE PROPOSED POSSIBLE TRAFFIC DETOURS AT LEAST 72 HOURS PRIOR TO COMMENCING WORK. & ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TiMES DURING PROJECT CONSTRUCTION. REVISIONS PRO D DATE REFERENCES DATE BENCHMARK SCALE SPECIAL DISTRICT AS -BUILT APPROVALS CITY O F ENCINITAS ENGINEERING DEPARTMENT DRAWING NO. AS -BU /LT - '71 PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED APPROVED BYAL,4NARCN /BALD PUBLIC IMPROVEMENT PLANS FOR: AS NOTED HORIZONTAL AS SHOWN DATE. �i�� 0/f/ 7�/9101 STORM DRAIN IMPROVEMENTS STORM DRAIN REPLACEMENT BY: BY: VULCAN AVENUE SANTA FE DRIVE 0022"` DI ON SHEETS 2 & 3 VERTICAL AS SHOWN R.C.E. NO. LEROY BODAS R E NO. C 22312 ALAN ARCHIBALD RCE NO. C 21869 D STREET TO VISTA DEL REY DR. AT HOSPITAL AND SHOPPING CENTER ENGINEER EXP. DATE: DAB WORK PROJECT NO. CMD 998 a CMD 01B ENTRANCE SHEET 1 OF 3 i NoText NoText NoText NoText NoText NoText