1991-1018 R (Plans)N1379
1_
i
- - -- - - - _ - ( 4 -
- - j -�: -! -- -
- -- - -
!{� 1
Zf00 2f 50 3f00 _3f 50 �f00
•� EXIST PA/' /.f/G
C!/9B or ,SOIIiS'
Z •%
7 !1 - -
/l/OTE ,A,
A00 ? /On/fIL WO/7/f !✓ /L L 6E
�9EG'U /9.00 /F EX.CS`T //LE P/9YEMf I/T
SELT /O.V /.S /VOY ALLfP7 if6GE.
' %r. �cO.faz'covc. Sows- ry�s'ro r,-7J
Si1AVCUTfl.V00/Eh'LAY -� 1 � /A;9L SECT /o.V-
fI,S AAe sA.YY /J l P90I FULL OEPTh 5t5f'NAL
P/70✓rOE 's /%Gb7ff O.t/ST 6 "7Yi G ces w o X
77T,q,VS/T /O.V CO.t C. CYJ.9B 19<f6 5; !j-ZI CcN /G9
7 5EA2
--
�J
L
/t/O SCALE
OYE.9CC/7 F.fti^J GU77Fi9L/P
7a Tf1E _54,VC!/ G/.(/E TO FQ9M G(I71E.9 L/P
f AE�.src wmv FULL 5r.9Y/C7ZA9 -9t 5FC770 /. 0 Q
.vG7B�
THE EXISTING STREET SHALL BE CORE TESTED TO DETERMINE
THE EXISTING STRUCTURAL SECTION AND TO DETERMINE THE
EXTENT OF OVERLAY OR RECONSTRUCTION NECESSARY TO ACHIEVE n ri V J
THE REQUIRED "R" VALUES, TESTS SHALL BE PERFORMED AT
LOCATIONS APPROVED BY THE CITY ENGINEER. y h n C V \
�2 po N my t �
SITE
. hN N
0 �, pl � N � � � ♦ �' `l V � Dl 6�'KXfLON OEYiCE
S.O. N Q 3T17. P -5�
�. � k� � h � N3�Q �u \ 2'mrocsnc wArfarre�.v
♦ h V W 'kv I 3.0. .O. -5T0.
P-9
o;Q _ �;!
,� .Sq/✓CllT N0.9RY
4
7tJ • W �/� /f�EC� STO. G-ZJ
p Pi���/OE SMA?Tf1 CIl " N
0 So/✓/%7�T5ttiu. 3 p �. N 0 PflOP. COVEC• 50s✓s�
-- - ��-
� � �SAWCG/T�y f�E/Yrb/�E EX /ST `v�
/r7 .9.t42 C� -?AdF7 if/L/i"C!/.9,8
a6ln B//, SOwA � °9A,4/C� q7 u�H� W � -
\? p LGL�/TT /O t/ A e/O la9�GlES AS a J
M
NQ
�•.f LEGAL DESCR CHESTERFIELD DRIVE
1_ LOTS 5, 6 AND 7 IN BLOCK 31 OF TRACT 1369•
A RESUBDIVISION OF A PORTION OF CARDIFF, IN THE
COUNTY OF SAN DIEGO, STATE OF CALIFORNIA , ACCORDING
TO MAP 'WHEREOF NO. 1369, FILED IN THE OFFICE OF THE
COUNTY RECORDER OF SAN DIEGO COUNTY, JANUARY 15, 1912.
REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE SPECIAL DISTRICT
DESCRIPTION:1 /2" IRON PIN IN SAN DIEGUITO WATER DISTRICT
CONC. MON, IN CARDIFF O.C.0029
LOCATIONtAPPROX. 29' FROM SAN HORIZONTAL / °20 APPffO ✓EO
ELIJO AVE. BETWEEN 2 RR. TIE GUARD
POST ON PRLG. S. CB. LIVERPOOL DR. /._ a
RECORD FROM:S.D. COUNTY BENCHMKS VERTICAL
ELEV: 4.l P4 DATUMt5EA LEVEL,
OWNER'S STATEMENT
IT IS AGREED THAT FIELD CONDITIONS MAY REQUIRE CHANGES TO THESE
PLANS.
IT IS FURTHER AGREED THAT THE OWNER (DEVELOPER) SHALL HAVE A
REGISTERED CIVIL ENGINEER MAKE SUCH CHANGES, ALTERATIONS OR
ADDITIONS TO THESE PLANS WHICH THE DIRECTOR OF PUBLIC WORKS
DETERMINES ARE NECESSARY AND DESIRABLE FOR THE PROPER COMPLETION
OF THE IMPROVEMENTS.
I FURTHER AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS SHOWN ON
THESE PLANS WITHIN EXISTING COUNTY RIGHT -OF -WAY WITHIN 60 DAYS
AFTER ISSUANCE OF THE CONSTRUCTION PE)MIT AND TO PURSUE SUCH WORK
ACTIVELY ON .EVERY NORMAL WORKING DAY UNTIL COMPLETED, IRRESPECTIVE
AND INDEPENDENT OF ANY OTHER WORK ASSOCIATED WITH THIS PROJECT
OR UNDER MY CONTROL.
e_? Z7
CfIFfO /fi�-BY- T/a'E GQGI�E
�/.9�`7ES G. 57"1gTSE/F
74(o EOEGW6 /SS G9NE�
OL /YEA/f/A /N, CA. 92o
WORK TO BE DONE
THE IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE ACCORDING TO
THESE PLANS AND THE CURRENT COUNTY OF SAN DIEGO ENGINEERS DEPARTMENT
STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS FOR IMPROVEMENTS OF
SUBDIVISION STREETS AND THE REGIONAL STANDARD DRAWINGS.
LEGEND
IMPROVEMENT
STD. DWG. SYMBOL Q 7Y
EX /- 57 /�t/Ci CU.9B
EX /ST /�L/Ci S /OE/✓9Llr
PflO.R25E0 CO�r.0 Cl/RB
�-Z BB G.F
°/�OlY�5E0 CCWC S /GtE!✓9Gff
Ci - / 396 3. F.
PHOoosEO /79I�/ 1�Y
30 S F
1. A PERMIT SHALL BE OBTAINED FROM THE COUNTY DEPARTMENT OF TRANS-
PORTATION FOR ANY WORK WITHIN THE STREET RIGHT -OF -WAY.
2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH SAN DIEGO
COUNTY STANDARDS AND AS APPROVED BY THE MATERIALS LABORATORY
(SEE TYPICAL SECTION).
3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CONSTITUTE
APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT BOUNDARY.
4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL BE
CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF BERM, -
CURB, CROSS GUTTER AND PAVING.
5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE
RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO OTHER
EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS, HOWEVER,
THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO
PROTECT ANY EXISTING FACILITY SHOWN HEREON AND ANY OTHER WHICH
IS NOT OF RECORD OR NOW SHOWN ON THESE PLANS.
6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE
DONE SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR TO CONSTRUCTION
OF NEW WORK. CONTRACTOR WILL MAKE EXPLORATORY EXCAVATIONS AND
LOCATE EXISTING UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF
CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE
NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING FACILITIES.
7. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS AND ELECTRIC COMPANY
PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE
HIS WORK WITH COMPANY REPRESENTATIVES.
NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE
"UNDERGROUND INSTALLATIONS." FOR LOCATION OF ELECTRICAL
CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE
SAN DIEGO GAS AND ELECTRIC COMPANY.
TELEPHONE: (9Lb) 4Z2-t1.9_3
8. THE CONTRACTOR SHALL NOTIFY THE PACIFIC TELEPHONE COMPANY PRIOR
TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL COORDINATE
HIS WORK WITH COMPANY REPRESENTATIVES.
NOTICE: ALL TELEPHONE SERVICES WITHIN THIS PROJECT BOUNDARY ARE
"UNDERGROUND INSTALLATIONS." FOR LOCATION OF CABLES AND
APPURTENANCES CONTACT THE PACIFIC TELEPHONE COMPANY.
TELEPHONE t /gaol 4 J3
9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTACT THE
UTILITY AGENCIES, ADVISE THEM OF THE PROPOSED IMPROVEMENTS, AND
BEAR THE COST OF RELOCATIONS, IF NEEDED.
10. ALL TELEVISION SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND
INSTALLATIONS ". FOR LOCATION OF CABLES AND APPURTENANCES CONTACT
11. POWER SOURCES AND RUNS SERVING STREET LIGHTS SHALL BE SHOWN ON
THE "AS- BUILT" IMPROVEMENT DRAWINGS. ALL SOURCES SHALL BE LOCATED
WITHIN THE DEDICATED RIGHT -OF -WAY OR WITHIN EASEMENTS DEDICATED
TO THE COUNTY OF SAN DIEGO.
12. NO PAVING SHALL BE DONE UNTIL ALL EXISTING POWER POLES ARE
RELOCATED OUTSIDE THE AREAS TO BE PAVED.
13. ALL LUMINAIRES SHALL PROVIDE TRUE 90 CUTOFF, AND ALLOW NO ESCAPE
OF LIGHT ABOVE THE HORIZONTAL.
14. ALL. aR0, - ,6A1 A.C. Q1gy 1.(16 OF ALLEY AZZIO /N /,VG P f0,lvei)7y, S/lAGL ALE
f/EMOI'EO A.f/O A'EPL.9Cf.0 TO TF/E 3�grjSFi�T /GN/ �- Tl1E O /9EGT09 �
GY/BL /C
15. CONTRACTOR SHALL REQUEST FROM THE CITY ENGINEERS
OFFICE A PRECONSTRUCTION MEETING AND SHALL PROVIDE
AT LEAST 48 HOURS NOTICE FOR SUCH A MEETING.
DECLARATION OF RESPONSIBLE CHARGE
I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS
PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE
DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE
BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSIS-
TANT WITH CURRENT STANDARDS.
I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND
SPECIFICATIONS BY THE COUNTY OF SAN DIEGO IS CONFINED TO A
REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINNER OF WORK,
OF MY RESPONSIBILITIES FOR PROJECT DESIGN.
PIRO ENGINEERING
920 BOARDWALK STE.A
SAN MARCOS, CA. 92069
(619) 744 -3700
(24
BY: ,?/o_-.n, K , �� a DATE Z /B -9l
v
R.C.E. No. 24 000
EXPIRATION DATE
11 E/t/Yi/AlAe4 -Ir/Xl
910 Am"vre7*wte,4 .3Y/17Zr
.-r-q / /•7q/fCOS CA. 9ZGti9
�7Y ,qE� /STNAT /O�t/ dX�° /�9BS
O,(/ /Z -.3/- 93
DESIGNE BY I DRAWN BY i CHECKED BY
PLANS PREPARED UNDER SUPERVISION OF
DATE :
a4ley /r //90 R.C.E. NO.: iftD00
ENGINEER
EXP. /Z -31-93
RECO�M
BY:
DATE:
"-E-.
APP
A
& -f-
DA TE:
CITY OF ENCINITAS PUBLIC WORKS DEPARTMENT
PLA.t/S FDi'P THE /�7P/117liElYILSVT OF
CHESTERFIELD DRIVE
WORK PROJECT NO.
O
C
y � y11 Q
�0
JA
Q `C
z m�
(Jn
LLJ
LLJ LLI
Z
Z T
DRAWING N0. LLJ Q
1618 R
_ SHEET / OF /
FILE N0. 4✓o z-acz
VIC 11N17Y /"7/91
A149 .50i94E