1989-9331 R (Plans) GENERAL NOTES STREET IMPROVEMENT P
WORK TO BE DONE
1. A PERMIT SHALL BE OBTAINED FROM THE CITY DEPARTMENT OF PUBLIC
WORKS FOR ANY WORK WITHIN THE STREET RIGHT -OF -WAY. IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE ACCORDING
TO THESE PLANS;
2. THE STRUCTURAL SECTION SHALL BE IN ACCORDANCE WITH CITY OF THE CURRENT SAN DIEGO COUNTY DEPARTMENT OF PUBLIC
WORKS STANDARD SPECIFICATIONS
ENCINITAS STANDARDS AND AS APPROVED BY THE CITY ENGINEER. AND SPECIAL PROVISIONS FOR IMPROVEMENT OF SUBDIVISION
STREETS AND STANDARD REFE-
RENCE DRAWINGS.
3. APPROVAL OF THESE IMPROVEMENT PLANS AS SHOWN DOES NOT CON-
STITUTE APPROVAL OF ANY CONSTRUCTION OUTSIDE THE PROJECT
BOUNDARY.
4. ALL UNDERGROUND UTILITIES WITHIN THE STREET RIGHT -OF -WAY SHALL LEGEND
BE CONSTRUCTED, CONNECTED AND TESTED PRIOR TO CONSTRUCTION OF ITEM SPECIFICATION SYMBOL QUANTITY
BERM, CURB, CROSS GUTTER AND PAVING.
AC PAVEMENT — 75 S.F.
5. THE EXISTENCE AND LOCATION OF EXISTING UNDERGROUND FACILITIES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE 6" AC BERM (TYPE A) STD DWG G -5 6 L.F.
iQ
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE
NO OTHER EXISTING FACILITIES EXCEPT AS SHOWN ON THESE PLANS. 6" TYPE "G" CURB & GUTTER STD DWG G -2 46
L.F.
HOWEVER, THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY
MEASURES TO PROTECT ANY EXISTING FACILITY SHOWN HEREON AND PCC SIDEWALK STD DWG G -7 �^'''_?� 170 S.F.
ANY OTHER WHICH IS NOT OF RECORD OR NOT SHOWN ON THESE PLANS.
PCC DRIVEWAY APRON STD DWG G -14 120 S.F.
6. LOCATION AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO
BE DONE SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR TO RELOCATE EXIST WATER METER — — y{]V 1 EA.
CONSTRUCTION OF NEW WORK. CONTRACTOR WILL MAKE EXPLORATORY
EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES SUFFI- AC OVERLAY — ® 938 S.F.
CIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF
REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING
FACILIITES.
7. THE CONTRACTOR SHALL NOTIFY THE SAN DIEGO GAS & ELECTRIC
COMPANY PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND
SHALL COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES.
NOTICE: ALL ELECTRICAL AND GAS SERVICES WITHIN THIS PROJECT ARE
"UNDERGROUND INSTALLATIONS ". FOR LOCATION OF ELECTRICAL
CABLES AND GAS PIPING AND APPURTENANCES CONTACT THE
DIEGO GAS & ELECTRIC COMPANY.
TELEPHONE: 1- 800 - 422 -4133
8. THE CONTRACTOR SHALL NOTIFY THE PACIFIC TELEPHONE COMPANY
PRIOR TO STARTING WORK NEAR COMPANY FACILITIES AND SHALL LEGAL DESCRIPTION
COORDINATE HIS WORK WITH COMPANY REPRESENTATIVES. LOT 19, BLOCK 5, MAP 1859, CITY OF ENCINITAS, COUNTY
NOTICE: ALL TELEPHONE SERVICES WITHIN THIS PROJECT BOUNDARY OF SAN DIEGO, STATE OF CALIFORNIA.
ARE "UNDERGROUND INSTALLATIONS ". FOR LOCATION OF
CABLES AND APPURTENANCES CONTACT THE PACIFIC TELE- A.P.N. 254 - 242 -20
PHONE COMPANY.
TELEPHONE: 1- 800 - 422 -4133.
9. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO CONTAC
THE UTILITY AGENCIES, ADVISE THEM OF THE PROPOSED IMPROVE- OWNER CERTIFICATE
MENTS, AND BEAR THE COST OF RELOCATIONS, IF NEEDED.
IT IS AGREED THAT FIELD CONDITIONS MAY REQUIRE CHANGES TO THESE PLANS.
10. ALL TELEVISION SERVICES WITHIN THIS PROJECT ARE "UNDERGROUND
INSTALLATIONS ". FOR LOCATION OF CABLES AND APPURTENANCES IT IS FURTHER AGREED THAT THE OWNER (DEVELOPER)
SHALL HAVE A REGISTERED
CONTACT DANIELS CABLEVISION. TELEPHONE: 1- 800 - 422 -4133 CIVIL ENGINEER MAKE SUCH CHANGES, ALTERATIONS OR
ADDITIONS TO THESE PLANS
WHICH THE DIRECTOR OF THE PUBLIC WORKS DETERMINES ARE NECESSARY AND
11. POWER SOURCES AND RUNS SERVING STREET LIGHTS SHALL BE DESIRABLE FOR THE PROPER COMPLETION OF THE IMPROVEMENTS.
SHOWN ON THE "AS- BUILT" IMPROVEMENT DRAWINGS. ALL SOURCES
SHALL BE LOCATED WITHIN THE DEDICATED RIGHT -OF -WAY, OR I I I FURTHER AGREE TO COMMENCE WORK ON ANY IMPROVEMENTS
SHOWN ON THESE
WITHIN EASEMENTS DEDICATED TO THE CITY OF ENCINITAS. '" I PLANS WITHIN EXISTING CITY RIGHT -OF -WAY WITHIN
60 DAYS AFTER ISSUANCE OF
THE CONSTRUCTION PERMIT AND TO PURSUE SUCH WORK ACTIVELY ON EVERY
12. PAVING SHALL NOT BE PERMITTED UNTIL EXISTING POWER POLES '
NORMAL WORKING DAY UNTIL COMPLETED, IRRESPECTIVE AND INDEPENDENT OF ANY
ARE RELOCATED OUTSIDE THE AREAS TO BE PAVED. I OTHER WORK ASSOCIATED WITH THIS PROJECT OR UNDER MY CONTROL.
a COLLIN JONES I z
1149 CORNISH IVE
PHOEBE STREET I ENCINITAS, CA 9 024
-- o — — - -- — — — - F M - - -- - -- — a - -- - - � (619) 753 -2898
N a l B I
E-E
O �I I
I 90' I25' DECLARATION OF RESPONSIBLE CHARGE
0120 1 1 I I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I
PROJECT HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS
SITE LEGEND i DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THE
Q - INDICATES PLAN DESIGN IS CONSISTENT WITH CURRENT STANDARDS.
SHEET NO.
_w--EXIST WATER LINE I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY
_ - -EXIST SEWER LINE THE CITY OF ENCINITAS IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE
Z ? D _ ME OF RESPONSIBILITIES FOR PROJECT DESIGN.
m
C- a z Z
TA RESOURCE DEVELOPMENT CORPORATION
ENCINITAS, CA CA 92024 E� Cf'i4 Ec,✓,I o
KEY MAP F
(619) 942 -1106 , � '��
pEBE ST GUS Sr SCALE 1 " =100' �Q�p CI C /., // Z
o A HJ BUILT BY: — * a
FH BRIAN %yam - BRIAN DONALD 's r te" • p
�� No. DONALD = y= RCE NO. 26175 LIC. EXP DATE: 3 -31 -90 9 r
CI VIL * 2 /2t /9 I> r �/ f �. Z
CI VIL
v'� Professional m
o�f...�;o, �'BeI<s r.I >.Ia,Ln, P_cE z(ons SITE ADDRESS o WILO\
....... , " 153 PHOEBE STREET
>Z LEUCADIA BL AD LEUCADIA, CA 92024 0
W to
FIRE PROTECTION AGENCY SEWER AGENCY WATER AGENCY
ENCINITAS FIRE DEPARTMENT A IA COUNTY R DISTRICT SAN DIEGUITO WATER DISTRICT SPECIAL USE PERMIT N0. 88-
328 -DR w
N u�
REZONE NO. NA ..
CO
VICINITY MAP APPROVED BY: APPROVED BY: APPROVED BY: �•A z
(NO SCALE) GRADING PERMIT NO. NA V) o
DATE: DATE: DATE: (NO GRADING PERMIT ISSUED w Z
OR REQUIRED FOR THIS SITE ) z z
REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE SPECIAL DISTRIC A Y APPROVALS CITY OF ENCINITAS PUBLIC
WORKS DEPARTMENT DRAWING NO. w a
Ar- DEEM W-AGT)4 1-911
'5 • CG 2964 4/11/ 3" BRASS DISK BELOW PLASTIC CAP PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED APP VED PLANS
FOR THE IMPROVEMENT OF:
s- t�utL-T i- MARKED USC & GS 1307 LOCATED
DATE: 1� 3 j$� BY: � BY:
ACROSS RR TRACKS FROM POST HORIZONTAL CITY ENGINEER A PORTION OF 9331—R
OFFICE 16' E. OF E. RAIL R.C.E. NO.: 26175 DATE: ( Sdac - .69 m
DATE: at, I Im
ELEVATION: 55.008' MSL VERTICAL ENGINEER PHOEBE STREET
EXP. 3/31/90 R.C.E. �, �L4' R.C.E. C2tb�t� SHEET 1 OF 2
WORK PROJECT N0.
RESOURCE DEVELOPMENT CORPORATION JN89 -23C
(619) 942 -1106
-- - T -
- - - i
- - -- - -
- - - - PL - - - !i --
PROFILE
1 „ =10' HORIZONTAL - - - -
-- - - 1 - VERTICAL
- - -
- _ - - - 8
- - - - - - - -- -- - -
fj
I t -- - -- - -
- - - - -
-- - EX 7T 7a -
5 +00 +50 4 +00 +50 3 +00
STATIONING NOTE
x o O �c STATIONING IS BASED ON 0 +00
N
EXIST EP. LOCATED AT THE C L INTERSECTION
Q � o /
V 3 OF PHOEBE STREET AND OLD HIGH-
N 747630" E O I- " WAY 101.
+50 E VQP S EW tR
w w o w ��
0 0 EXS � �6 A WA TAR MCI [N ^�
(39.5 ,4C 04f� m o
C
,y ____
R/W izt'YAirtlniC� WALL �� — - - -- - -- - - - --
°.
C/L R/W EX /ST C B, GU rTER & SW
PER CO. F SAN DIEGO
4.5' 5.5' 20' 20' NOTE ��\P ° ° ° °
° OWG NO. CG 2964
FLARE END OF BERM E J ° °
14' 8' AS SHOWN R G L.F AG r3�P
0
0
EXIS77NG GRADE d 5� k �G {' , 3 ~_ _ 0 CL
( J
= N v Q W Q 0 5 10 20 30 40 0
\ EXIST /NG GRADE Q � >_ O �� V Q
NEW PCC SIDEWALK n n W SR SCALE: 1 " = 10' w
EXIST AC PKMT
PER S7D DWG G -7 "A & BASE
V o =
NEW CURB & GUTTER Z m p o J 0 0
V
AC h�v "�o
Ld
PER STD DWG G -2 � a
W/8 D.G. BASE. FOR 2% CROSS FALL W
U
NEW AC PA t/EMENT &BASE „ ......,, �
4' AC OVER 6" CLASS 11 BASE SECTION AS - BUILT
PHOEBE STREET NN
`v�°'~i •• BRIAN •• "C�y.^ :
DONALD
4 + = 1-� Z /zI /9c>
" " ' No. 26175 � p W O^i
(NO SCALE) '� = ° # civil * `
• v'j% P of al Q; 1 3vA'r� L�eJALp, 1zC Zfo l - [S DA-> -� Q c0
Z v
9 31 -90
OF C���` ' o
n. „p...M w Z
W W
DESIGNED BY DRAWN BY y Z z
REVISIONS APPROVED DATE REFERENCES DATE BENCH MARK SCALE SPECIAL DISTRICT APPROVALS CITY OF ENCINITAS PUBLIC
WORKS DEPARTMENT DRAWING NO. w a_
$L�oNI El�l9r e2 rES r,� vJ Z1- 3” BRASS DISK BELOW PLASTIC CAP PLANS PREPARED UNDER SUPERVISION OF RECOMMENDED APP
VED PLANS FOR THE IMPROVEMENT OF:
v,sE Ac- 50M Loct�rr,*4 LI• v MARKED USC & GS #1307 LOCATED
/�5- pjJILT ACROSS RR TRACKS FROM POST HORIZONTAL 1"10' DATE: I2 BY: Q - - BY: A PORTION OF 9331
—R
n
OFFICE 16 E. OF E. RAIL `` CITY ENG NEER
ELEVATION: 55.008' MSL VERTICAL 1 ° =8' �� J R.C.E. NO.: 26175 DATE: DATE: �S j 1gZft
BRIAN DONALD 3/31/90 PHOEBE STREET
EXP. R.C.E. �, lE+g R.C.E. G2RbA WORK PROJECT N0. SHEET 2 OF 2
RESOURCE DEVELOPMENT CORPORATION JN89 -23C
(619) 942 -1106