Loading...
1993-3709 I/PE/PM Street Address ~/1ó Category I 379 13 Serial # -rPm13/ Ó33 I Description Name 11P( 3 Year Plan ck. # recdescv L / . p.O ENGINEERING, INC. 535 NORTH HIGHWAY 101. SUITE A SOLANA BEACH. CA 92075 [619] 259-8212 FAX [619] 259-4812 8 ,/ WAYNE A. PASCO R.C.E. 29577 September 10, 1993 m Œ (~ ~ Ii iïJ ~ ~E 525F SEP 1 0 1993 ENGINEERING SERVICES CITY OF ENCINITAS City of Encinitas 505 So. Vulcan Encinitas, CA 92024 Attn: Hans Jensen RE: TPM 93-032 HYDROLOGY Dear Mr. Jensen: The purpose of this report is to calculate the existing Q100 that crosses the offsite private easement road as proposed by the Improvement Plans for "Burgundy Road (Private)". The existing runoff tributary to the low point in Burgundy Road (Node 1, Exhibit A) is 8.89 cfs as calculat~d herein. The . . , proposed development does not 1n any way 1ncr~se or furth~ concentrate the 100 year runoff from the existing condition.\ '. Due to the fact that a subterrainian storm drain system requires acquisition of offsite easement rights, and is not warranted, Burgundy Road was designed to simulate the existing drainage patterns and flows. In an effort to minimize potential erosion damage to adjacent properties, a 6" type 'A' AC berm is provided along the proposed west edge of pavement. (E.P.) A cutoff wall is then proposed underneath the west E.P. from the end of the berm to 25' south of the low point to protect the pavement and adjacent property from undermining and erosion. It is the professional opinion of Pasco Engineering that the proposed improvement of Burgundy Road will not increase the runoff or the potential for erosion damage to adjacent properties. If you have any questions regarding the above, please do not hesitate to contact us. WP/js Very truly yours, PASCO ENGINEERING, INC. i/J ~ tf? âI>c6 Wayne Pasco, President RCE 29577 õ.... 8 e **************************************************************************** RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT 1985,1981 HYDROLOGY MANUAL (c) Copyright 1982-92 Advanced Engineering Software (aes) Ver. 1.3A Release Date: 3/06/92 License ID 1388 Analysis prepared by: PASCO ENGINEERING, INC. 535 NORTH HWY. 101, SUITE A SOLANA BEACH, CA. 92075 PHONE: (619) 259-8212 FAX: (619) 259-4812 ************************** DESCRIPTION OF STUDY ************************** * YDROLOGY ANALYSIS * SUSI PE 525F * * 100 YEAR STORM; TYPE "D" SOIL. * * SEE EXHIBIT "A". * 9/9/93 MS * ************************************************************************** - -------------------------------------------------------------------------- SER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ILE NAME: 525HYDRO.DAT IME/DATE OF STUDY: 15:53 9/ 9/1993 ---------------------------------------------------------------------------- SAN DIEGO MANUAL CRITERIA SER SPECIFIED STORM EVENT(YEAR) = 100.00 6-HOUR DURATION PRECIPITATION (INCHES) = SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DEClMAL) TO USE SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED OTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED 2.600 FOR FRICTION SLOPE = .95 * ************************************************************************** FLOW PROCESS FROM NODE 3.00 TO NODE 2.00 IS CODE = 21 - -------------------------------------------------------------------------- »»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««< = ========================================================================== SOIL CLASSIFICATION IS "D" ULTI-UNITS DEVELOPMENT RUNOFF COEFFICIENT = .7000 INITIAL SUBAREA FLOW-LENGTH = 400.00 UPSTREAM ELEVATION = 234.00 DOWNSTREAM ELEVATION = 230.50 ELEVATION DIFFERENCE = 3.50 URBAN SUBAREA OVERLAND TIME OF FLOW (MINUTES) = 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.365 SUBAREA RUNOFF(CFS) = 2.64 TOTAL AREA(ACRES) = 1.12 15.055 TOTAL RUNOFF(CFS) = 2.64 * ************************************************************************** FLOW PROCESS FROM NODE 2.00 TO NODE 1.00 IS CODE = 52 - -------------------------------------------------------------------------- »»>COMPUTE NATURAL VALLEY CHANNEL FLOW««< »»>TRAVELTIME THRU SUBAREA««< , . - - = ========================~========================~=================== UPSTREAM NODE ELEVATION = 230.50 DOWNSTREAM NODE ELEVATION = 201.40 CHANNEL LENGTH THRU SUBAREA(FEET) = CHANNEL SLOPE = .0560 CHANNEL FLOW THRU SUBAREA (CFS) = 2.64 FLOW VELOCITY(FEET/SEC) = 4.32 (PER PLATE D-6.1) TRAVEL TIME(MIN.) = 2.01 TC(MIN.) = 17.06 520.00 * ************************************************************************** FLOW PROCESS FROM NODE 2.00 TO NODE 1. 00 IS CODE = 8 - -------------------------------------------------------------------------- »»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW««< - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.104 SOIL CLASSIFICATION IS "D" SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500 SUBAREA AREA(ACRES) = 3.66 SUBAREA RUNOFF(CFS) = TOTAL AREA(ACRES) = 4.78 TOTAL RUNOFF(CFS) = TC(MIN) = 17.06 6.25 8.89 - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- END OF STUDY SUMMARY: PEAK FLOW RATE(CFS) = TOTAL AREA(ACRES) = 8.89 4.78 Tc(MIN.) = 17.06 - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- END OF RATIONAL METHOD ANALYSIS õ 8 8 * ************************************************************************** HYDRAULIC ELEMENTS - I PROGRAM PACKAGE (C) Copyright 1982-92 Advanced Engineering Software (aes) Ver. 3.1A Release Date: 2/17/92 License ID 1388 Analysis prepared by: PASCO ENGINEERING 535 NORTH HWY 101, SUITE A SOLANA BEACH, CA. 92075 PHONE: (619) 259-8212 FAX (619) 259-4812 - -------------------------------------------------------------------------- TIME/DATE OF STUDY: 16: 9 9/ 9/1993 - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- ************************* DESCRIPTION OF STUDY ************************** * DEPTH OF FLOW CALCULATION. * SUSI PE 525F * * NODE 1, EXHIBIT "A", LOW POINT OF ROAD. * * * SEE IMPROVEMENT PLANS. * 9-9-93 MS * ************************************************************************* * ************************************************************************** > »CHANNEL INPUT INFORMATION«« - -------------------------------------------------------------------------- CHANNEL Zl(HORIZONTAL/VERTICAL) = Z2(HORIZONTAL/VERTICAL) = BASEWIDTH(FEET) = .00 CONSTANT CHANNEL SLOPE(FEET/FEET) = UNIFORM FLOW(CFS) = 8.90 MANNINGS FRICTION FACTOR = .0170 100.00 100.00 .020000 - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- NORMAL-DEPTH FLOW INFORMATION: - -------------------------------------------------------------------------- »»> NORMAL DEPTH(FEET) = FLOW TOP-WIDTH(FEET) = FLOW AREA(SQUARE FEET) = HYDRAULIC DEPTH(FEET) = .09 FLOW AVERAGE VELOCITY(FEET/SEC.) = UNIFORM FROUDE NUMBER = 1.432 PRESSURE + MOMENTUM(POUNDS) = AVERAGED VELOCITY HEAD(FEET) = SPECIFIC ENERGY(FEET) = .286 .19 37.77 3.57 2.50 57.05 .097 - -------------------------------------------------------------------------- - -------------------------------------------------------------------------- CRITICAL-DEPTH FLOW INFORMATION: - -------------------------------------------------------------------------- CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL AVERAGED CRITICAL FLOW TOP-WIDTH(FEET) = FLOW AREA(SQUARE FEET) = FLOW HYDRAULIC DEPTH(FEET) = FLOW AVERAGE VELOCITY(FEET/SEC.) = DEPTH (FEET) = .22 FLOW PRESSURE + MOMENTUM(POUNDS) = CRITICAL FLOW VELOCITY HEAD(FEET) = FLOW SPECIFIC ENERGY(FEET) = .272 43.63 4.76 .11 1.87 53.85 .054 = ========================================================================== - --, COUlITV OF" SAN DIEGO DEPARTMENT OF SANITATION & FLOOD CONTROL --20../ ù \ . I" \ \ :< ~\ \ \ --. -..< (\ .' ¡:?~Jæ:T ¿oCA-77ó¿<) 330 301 151 1160 ---u1 , COUNTY OF SAN DIEGO DEPARTMENT OF SANITATION & FLOOD CONTROL 451 . 301 IS' 33° PKClT'éLT /71. . ~ tV /1/7°(717/' tV ~7DClr'3tJ., 451 . l p":~,,, - u.s. DEPARTilIEr-;rr OF- COMMERCE NATIONAL OCEA:-."IC A="D ATJOSPHERIC ADMINISTRATION I SPECIAL STUDIES BRANCH, OFFICE OF IITDROLOGY, NATIONAL WEATHER SERVICE 301 H t-< I ;Þ 118° 451 30. 151 I 17° 451 30' 15' I] 6° VJ / ......---. - / ---- ~ q;;¡ <:.":) . ., ,.,..) -~--;.". .\' \\,