TPM 93-032
HYDROLOGY
Dear Mr. Jensen:
The purpose of this report is to calculate the existing Q100 that
crosses the offsite private easement road as proposed by the
Improvement Plans for "Burgundy Road (Private)".
The existing runoff tributary to the low point in Burgundy Road
(Node 1, Exhibit A) is 8.89 cfs as calculat~d herein. The
. . ,
proposed development does not 1n any way 1ncr~se or furth~
concentrate the 100 year runoff from the existing condition.\
'.
Due to the fact that a subterrainian storm drain system requires
acquisition of offsite easement rights, and is not warranted,
Burgundy Road was designed to simulate the existing drainage
patterns and flows. In an effort to minimize potential erosion
damage to adjacent properties, a 6" type 'A' AC berm is provided
along the proposed west edge of pavement. (E.P.) A cutoff wall
is then proposed underneath the west E.P. from the end of the
berm to 25' south of the low point to protect the pavement and
adjacent property from undermining and erosion.
It is the professional opinion of Pasco Engineering that the
proposed improvement of Burgundy Road will not increase the
runoff or the potential for erosion damage to adjacent
properties.
If you have any questions regarding the above, please do not
hesitate to contact us.
WP/js
Very truly yours,
PASCO ENGINEERING, INC.
i/J ~ tf? âI>c6
Wayne Pasco, President
RCE 29577
õ.... 8 e
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-92 Advanced Engineering Software (aes)
Ver. 1.3A Release Date: 3/06/92 License ID 1388
Analysis prepared by:
PASCO ENGINEERING, INC.
535 NORTH HWY. 101, SUITE A
SOLANA BEACH, CA. 92075
PHONE: (619) 259-8212 FAX: (619) 259-4812
************************** DESCRIPTION OF STUDY **************************
* YDROLOGY ANALYSIS * SUSI PE 525F *
* 100 YEAR STORM; TYPE "D" SOIL. *
* SEE EXHIBIT "A". * 9/9/93 MS *
**************************************************************************
- --------------------------------------------------------------------------
SER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
ILE NAME: 525HYDRO.DAT
IME/DATE OF STUDY: 15:53
9/ 9/1993
----------------------------------------------------------------------------
SAN DIEGO MANUAL CRITERIA
SER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) =
SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00
SPECIFIED PERCENT OF GRADIENTS(DEClMAL) TO USE
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED
OTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED
2.600
FOR FRICTION SLOPE =
.95
* **************************************************************************
FLOW PROCESS FROM NODE
3.00 TO NODE
2.00 IS CODE =
21
- --------------------------------------------------------------------------
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
= ==========================================================================
SOIL CLASSIFICATION IS "D"
ULTI-UNITS DEVELOPMENT RUNOFF COEFFICIENT = .7000
INITIAL SUBAREA FLOW-LENGTH = 400.00
UPSTREAM ELEVATION = 234.00
DOWNSTREAM ELEVATION = 230.50
ELEVATION DIFFERENCE = 3.50
URBAN SUBAREA OVERLAND TIME OF FLOW (MINUTES) =
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.365
SUBAREA RUNOFF(CFS) = 2.64
TOTAL AREA(ACRES) = 1.12
15.055
TOTAL RUNOFF(CFS) =
2.64
* **************************************************************************
FLOW PROCESS FROM NODE 2.00 TO NODE 1.00 IS CODE = 52
- --------------------------------------------------------------------------
»»>COMPUTE NATURAL VALLEY CHANNEL FLOW««<
»»>TRAVELTIME THRU SUBAREA««<
, . - -
= ========================~========================~===================
UPSTREAM NODE ELEVATION = 230.50
DOWNSTREAM NODE ELEVATION = 201.40
CHANNEL LENGTH THRU SUBAREA(FEET) =
CHANNEL SLOPE = .0560
CHANNEL FLOW THRU SUBAREA (CFS) = 2.64
FLOW VELOCITY(FEET/SEC) = 4.32 (PER PLATE D-6.1)
TRAVEL TIME(MIN.) = 2.01 TC(MIN.) = 17.06
520.00
* **************************************************************************
FLOW PROCESS FROM NODE
2.00 TO NODE
1. 00 IS CODE =
8
- --------------------------------------------------------------------------
»»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW««<
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.104
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA(ACRES) = 3.66 SUBAREA RUNOFF(CFS) =
TOTAL AREA(ACRES) = 4.78 TOTAL RUNOFF(CFS) =
TC(MIN) = 17.06
6.25
8.89
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
END OF STUDY SUMMARY:
PEAK FLOW RATE(CFS) =
TOTAL AREA(ACRES) =
8.89
4.78
Tc(MIN.) =
17.06
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
END OF RATIONAL METHOD ANALYSIS
õ 8 8
* **************************************************************************
HYDRAULIC ELEMENTS - I PROGRAM PACKAGE
(C) Copyright 1982-92 Advanced Engineering Software (aes)
Ver. 3.1A Release Date: 2/17/92 License ID 1388
Analysis prepared by:
PASCO ENGINEERING
535 NORTH HWY 101, SUITE A
SOLANA BEACH, CA. 92075
PHONE: (619) 259-8212 FAX (619) 259-4812
- --------------------------------------------------------------------------
TIME/DATE OF STUDY: 16: 9
9/ 9/1993
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
************************* DESCRIPTION OF STUDY **************************
* DEPTH OF FLOW CALCULATION. * SUSI PE 525F *
* NODE 1, EXHIBIT "A", LOW POINT OF ROAD. * *
* SEE IMPROVEMENT PLANS. * 9-9-93 MS *
*************************************************************************
* **************************************************************************
> »CHANNEL INPUT INFORMATION««
- --------------------------------------------------------------------------
CHANNEL Zl(HORIZONTAL/VERTICAL) =
Z2(HORIZONTAL/VERTICAL) =
BASEWIDTH(FEET) = .00
CONSTANT CHANNEL SLOPE(FEET/FEET) =
UNIFORM FLOW(CFS) = 8.90
MANNINGS FRICTION FACTOR = .0170
100.00
100.00
.020000
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
NORMAL-DEPTH FLOW INFORMATION:
- --------------------------------------------------------------------------
»»> NORMAL DEPTH(FEET) =
FLOW TOP-WIDTH(FEET) =
FLOW AREA(SQUARE FEET) =
HYDRAULIC DEPTH(FEET) = .09
FLOW AVERAGE VELOCITY(FEET/SEC.) =
UNIFORM FROUDE NUMBER = 1.432
PRESSURE + MOMENTUM(POUNDS) =
AVERAGED VELOCITY HEAD(FEET) =
SPECIFIC ENERGY(FEET) = .286
.19
37.77
3.57
2.50
57.05
.097
- --------------------------------------------------------------------------
- --------------------------------------------------------------------------
CRITICAL-DEPTH FLOW INFORMATION:
- --------------------------------------------------------------------------
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
AVERAGED
CRITICAL
FLOW TOP-WIDTH(FEET) =
FLOW AREA(SQUARE FEET) =
FLOW HYDRAULIC DEPTH(FEET) =
FLOW AVERAGE VELOCITY(FEET/SEC.) =
DEPTH (FEET) = .22
FLOW PRESSURE + MOMENTUM(POUNDS) =
CRITICAL FLOW VELOCITY HEAD(FEET) =
FLOW SPECIFIC ENERGY(FEET) = .272
43.63
4.76
.11
1.87
53.85
.054
= ==========================================================================
- --,
COUlITV OF" SAN DIEGO
DEPARTMENT OF SANITATION &
FLOOD CONTROL
--20../
ù
\
. I"
\ \
:<
~\
\ \
--.
-..<
(\
.'
¡:?~Jæ:T
¿oCA-77ó¿<)
330
301
151
1160
---u1
,
COUNTY OF SAN DIEGO
DEPARTMENT OF SANITATION &
FLOOD CONTROL
451
.
301
IS'
33°
PKClT'éLT
/71. .
~
tV /1/7°(717/'
tV ~7DClr'3tJ.,
451 . l
p":~,,, -
u.s. DEPARTilIEr-;rr OF- COMMERCE
NATIONAL OCEA:-."IC A="D ATJOSPHERIC ADMINISTRATION
I
SPECIAL STUDIES BRANCH, OFFICE OF IITDROLOGY, NATIONAL WEATHER SERVICE
301
H
t-<
I
;Þ
118°
451
30.
151
I 17°
451
30'
15'
I] 6°
VJ
/
......---.
-
/ ---- ~ q;;¡
<:.":)
. .,
,.,..)
-~--;.".
.\'
\\,