1994-4041 G 1J { ~ 5 Category H c tr ( Name 6-J Plan ck. # recdescv Street Address I l-{35G5 Serial # I Description Year _. ALLIED EARTH TECHNOLOGY I j ROBERT CHAN, P.E. 1466 PIONEER WAY, SUITE 8 EL CAJON, CALIFORNIA 92020 TELEPHONE (619) 447-4747 SEP 20 1994 April 7, 1994 Mr. Wayne Landry 3369 Rocking Horse Circle Encinitas, CA. 92024 Subject: Project No. 94-25F301 Report of Compacted Filled Proposed Tennis Court Site 3369 Rocking Horse Circle Encinitas, California Ground Dear Mr. Landry: This report records our observations and the results of tests performed in connection with our inspection of the compaction of fill soils placed on certain areas of the proposed tennis court site on subject property, more specifically referred to as being Lot 50, according to Map thereof No. 11809, in the City of Encinitas, State of California. The grading reported herein was accomplished during the period between March 31 and April 6,1994, inclusive. Prior to grading, the site was cleared and grubbed. A key was excavated along the toe of the proposed fill slope through the topsoils into the underlying competent natural materials. All fill soils were then properly moistend, and uniformly compacted in lifts on the order of 6 to 8 inches. The depths of fill at which the tests were taken and the final test results are presented on page T-l, under "Table of Test Results". The laboratory determinations of the maximum dry density and optimum moisture content of the fill materials are set forth on the same page, under "Laboratory Test Results". The approximate location of the compacted filled ground and field density tests are presented on Figure No.1, entitled, "Approximate Location of Compacted Filled Ground" . Project No. 94-25F30l Mr. Wayne Landry 04/07/94 Page 2 The results of the tests and observations indicate that the soils placed and tested have been compacted to at least 90 percent of maximum dry density. Test results indicate that these fill soils will support the proposed tennis court without detrimental settle- ment. Laboratory test results indicate that the soils encountered on the site possess high expansion potential (Expansion Index = 92). It is recommended that the highly expansive nature of these soils be taken into consideration when design the concrete slab of the proposed tennis court. Post-tension slabs are recommended. Proper control of the site drainage and regular maintenance of all drainage facilities are important factors related to the overall stability of the soil mass. No surface water should be allowed to collect and/or pond on the building pad, and the runoff should be directed to flow into the street gutter or other suitable on-site drainage facilities. A safe allowable soil bearing value of 1,500 pounds per square foot may be used for the design of foundations, as presented in Table 29- B of the Uniform Building Code for clayey sands. Should you have any questions regarding the contents of this report, please feel free to contact our office at your convenience. This opportunity to be of service is sincerely appreciated. Page T-1, and Figure No. 1 are parts of this report. (3) Addressee - . .....-. ~ .---- tJLI VEhHlIlN '/I TE K to. lIfE ¡.flAlT ~ r--- ) j --- -:-- i I ~ . --- ~ . - '---?- -Ç 'I W.;' /1 ~ d .....¡ ~--u 1-1 r---¥ I. 0 r- -, \ lJ.¡ ~ ~ I ~~ I \ \ ~ f!j t.¡~ "'" ~ L _I . (? ~ .~ o. 0 Q:' lü1' LEGEND JlfPROY//1/ITE LtJ(fJT/t'N O¡::((J!1PlltTEll FILL£[! 6KtJUNO ~ IIPPl't'I/HIlTE LtZ'/T1tJN t'F RE/JJ PENf/TJI TEffT 11-/1- llílfL/áW UN.ë TJ? OF g¿tJf'£ TfJE ðF 5LOPE APPROXIMATE LOCATION OF COMPACTED FILLED GROUND PROJECT NO. 94-25F301 . ~, FIGURE NO.1 Project No. 94-25F301 Mr. Wayne Landry 04/07/94 Page T-1 LABORATORY TEST RESULTS 1. The maximum dry density and optimum moisture content of the fill soils were determined in accordance with A.S.T.M. D1557-78, Method A. The results of the test are presented as follows: Soil Type Description Maximum Optimum Dry Density Moisture Content (lbs./cu.ft.) (% Dry wt.) 1 Reddish brown clayey sand 123.0 11. 5 2. The Expansion Index of the most clayey soils encountered was determined in accordance with UBC Test Method 29-2. The results of the test are presented as follows: Soil Type Description Expansion Index 1 Reddish brown clayey sand 92 * * Considered to have high expansion potential TABLE OF TEST RESULTS ----- -- ---- ------- ----- -- ---- ------- Depth of Fill Moisture Dry Maximum Date Test Soil at Test Content Density Dry Density Relative of No. Type ((Ft.){% Dry Wt.)(lb./cu.ft.)(lb./cu.ft.) Compaction Test 1 1 + 2 13.1 114.5 123.0 93.1 03/31/94 2 1 + 4 17.3 111.4 123.0 90.5 04/01/94 3 1 + 6 13.2 110.7 123.0 90.0 04/06/94 4 1 + 6 14.1 112.1 123.0 91.1 04/06/94