1989-10 ~ RESOLUTION NO. 89-10 8 A RESOLUTION OF THE LEUCADIA COMMUNITY ADVISORY BOARD, CITY OF ENCINITAS, RECOMMENDING DENIAL BY THE PLANNING COMMISSION OF A TENTATIVE SUBDIVISION MAP AND MAJOR USE PERMIT FOR A 42.3 ACRE SITE LOCATED EAST OF SAXONY ROAD AT THE TERMINUS OF SWALLOWTAIL ROAD AND BELLA VISTA DRIVE (CASE NO.: 88-326 TM/MUP/EIA) WHEREAS, a Tentative Map to subdivide an existing 42.3 acre parcel into nineteen lots (one for +/- 26 acres of open space) and an application for a Major Use Permit to create a Planned Residential Development were filed by Fargo Industries Corporation; and, WHEREAS, Public Hearings were conducted by the Leucadia Community Advisory Board on the applications on March 16 and April 8 13, 1989; and, WHEREAS, the Leucadia Community Advisory Board found the following concerns, based on General Plan policies, and City development standards could not support a recommendation for eighteen (18) building lot sites: (1) Depth of Fill for Buildinq site Pads: The Board expressed a concern with the amount of fill needed to create building pads and driveway access. The amount of maximum fill on the 18 lots ranges from 0 to 14 feet. Section 23.24.460(I) of the Grading Ordinance reads: "FILL DEPTHS. Building structures upon fill materials in excess of 10 feet in depth shall not be allowed where all reasonable use of the property is otherwise precluded..." 8 CO/05/CRO6-302wp51(6-5-89\1) 8 (2) Pad Size and Relation to Lot Size: This concern raised by the Board related to usable pad area in relation to the lot size. The Board specifically denoted lots 6 through 12 as being small in width as compared to length and expressed concern over the small pad sizes. These pads range in size from approximately 10,000 to 13,000 square feet. Their ratio of pad to lot sizes range from 27 to 38 percent of the lot. This supports the Board's concern that the subdivision design may not conform to the intent of the General Plan's standard for the Rural Residential 1 Zoning Designation which states: "The purpose of this land use designation is to ensure that the rural character of certain areas of the City are maintained even with new residential development. This category is also useful in reducing the potential impacts of future development of sensitive areas in the City that would otherwise be affected by development at greater densities." 8 (3) Confiquration of Proposed Lots: The Board's discussion related to the "compact" nature of the width to length ratio of some of the proposed lots. In addition, the access needed for lots 5 and 6 is a 30 X 155 foot easement from "A" Street; and the amount of fill (approximately 17 feet) necessary to create a driveway access for lot 15 were expressed concerns of the Board. These concerns relate to the finding necessary to be made to exceed mid-range density of the zoning district. Specifically, that "the project design significantly exceeds the minimum standards for development". The present lot configuration would indicate that the applicant is striving for density above mid-range without consideration for a superior design. (4) Impacts to the Batiquitos Laqoon: The Board expressed a concern related to project impacts to Batiquitos Lagoon. The city's Environmental Consultant has specified the following mitigation measures intended to address this concern: 8 COjO5jCRO6-302wp52(6-5-89\1) A. All graded banks fronting the open space lot shall . be contoured with slopes varying from 1.5 to 1 through 2 to 1, averaglng 2 to 1, to simulate a natural landform. B. An erosion control landscape plan shall be prepared and implemented on the site. Drought tolerant, fire resistant, native plant materials shall be used. C. All grading activities shall be prohibited during the winter rain season (October 1st to April 15th) of each year. All permanent runoff and erOS1.on control devices shall be developed and installed prior to or concurrent with any on-site grading activities. D. A runoff control plan shall be prepared and implemented which will assure no increase in peak runoff rate from the developed site over the undeveloped site as a result of a 10 year frequency storm over a six-hour duration (10 year, 6 hour rainstorm). Runoff control shall be accomplished by such means as on-site detention and/or desiltation basins. Energy dissipating measures at the terminus of outflow drains shall be constructed. The Board expressed the opinion that the project, as proposed, 8 would not adequately protect environmentally constrained land to justify a density above mid-range (Section 30.16.010 B. 2. a. of the Zoning Ordinance); and, WHEREAS, due to expressed concerns, the Leucadia Community Advisory Board cannot recommend approval of the eighteen (18) buildable lot subdivision plan and still make the findings that: (a) The proposed map is consistent with the General Plan (Section 66474 of the Subdivision Map Act). (b) That the design or improvement of the proposed subdivision is consistent with the above mentioned General Plan policies and the City's Development Standards. (c) That the site is physically suitable for the proposed density of development. 8 CO/O5/CRO6-302wp5 3(6-5-89\1) . NOW THEREFORE, BE IT RESOLVED that the Leucadia Community Advisory Board recommends that the Planning Commission deny the 18 buildable and 1 open space lot subdivision as currently proposed. PASSED AND ADOPTED this 13th day of April, 1989 by the following vote, to wit: AYES: Kaden, Locko, Shur NAYS: Eldon, Harwood ABSENT: None /" / ABSTAIN: None /' Ir¡/ I i 1"'1 DOUGLAS HARWOOD, Chairperson of the Leu~adia Community 8 Advisory B1ard of the City of Encinitas¡ ATTEST: C~\ 1.V \2- C~~~ Craig R. Olson, Assistant Planner 8 CO/O5/CRO6-302Wp54(6-5-89\1)