Loading...
1984-02 Amending Administrative Code (Re: Fire Hydrants and Re: Construction Water) RESOLUTION NO. RB4-2 RESOLUTION OF THE B01\RD OF DIR&:'IO!lS OF SAN D=rTO WATER DISTRIcr AMENDING =STRATIVE aJDE (Re Fire IIydrants and Re COnstruction Water) WHEREAS, it is in the interest of the District to arrend its Mninistrative COOei NCW, THEREFORE, IT IS HEREBY RESOLVED, DETERMINED AND ORDERED by the Board of Directors of San Dieguito Water District as follows: 1. '!hat the San Dieguito Water District .Administrative Code be arrended. as set forth in Exhibit A hereto. 2. '!hat the San Dieguito Water District Administrative COde be amended as set forth in Exhibit B hereto. 3. Ohat the foregoing arrendnent shall take effect imrediately. PASSED AND AOOPI'ED at a regular meeting of the Board of Directors of San Dieguito Water District held on the 23rd day of January, 1984 by the following vote, to wit: AYES: Directors Weston, Dashiell, Weidner and TcMnsend. NOES: None. ABSEm': Director Stone. President A'ITEST: 81 AMENDMENT TO SAN DIEGUITO WATER DISTRICT ADMINISTRATIVE CODE Article 22 of the SAN DIEGUITO WATER DISTRICT ADMINISTRATIVE CODE is amended to read 25 follows: Article 22. Fire Hydrants. Sec. 22.1. Ownership. lines are the Fire hydrants on District property of the District. Sec. 22.2. Location. Subject to section 22.6 hereof, whenever the District installs a new water main, it shall also install, at its own expense, such fire hydrants as it deems beneficial to provide fire protection service to the area. Prior to such installation, the District shall consult with the Encinitas Fire Protection District ("fire agency"), but the San Dieguito Water District shall be the sole judge of the number, size and locaton of such fire hydrants. Sec. 22.3. New Development. Whenever property is rezoned, subdivided or otherwise developed, the owner or developer shall pay for the installation of such fire hydrants as the fire agency shall determine. Sec. 22.4. Hydrants Requested By Fire Aqency. The District shall install additional fire hydrants, or upgrade existing fire hydrants, on existing lines of the District upon request of the fire agency, developer or property owner, provided the District determines that it has facilities to supply adequate water thereto, and the person or organization requesting installation pays for the installation thereof. Sec. 22.5. Other New Hydrants. The District may install additional fire hydrants, or upgrade existing fire hydrants, on existing lines of the District, at its own expense, as it deems beneficial to provide fire protection service to an area. Prior to such installation, the District shall consult with the fire agency, but the District shall be the sole judge of the number, size and location of such fire hydrants. Sec. 22.6. Repairs. Repairs of fire hydrants shall be accomplished by the District. The fire agency shall remove weeds and paint hydrants. The District will enter into written agreement with the fire agency to implement the foregOing rules and to provide for the maintenance, - 1 - ~~A repair, replacement and use of fire hydrants. The District shall not install fire hydrants pursuant to section 22.2 or 22.4 unless such an agreement has been executed by the fire agency. Sec. 22.7. Use of Fire Hydrants. No person, other than the District or the fire agency, shall use a District hydrant for any purpose without the express written consent of the District. Fire hydrants may be used for construction purposes in the manner provided in Article 20 hereof. Sec. 22.8. Liability of District. Nothing provided in this article shall obligate the District to install any particular fire hydrant. Nothing provided herein shall give any rights to third parties or increase or otherwise change the liabilities or responsibilities of the District to property owners or other members of the public. - 2 - Article 20. Sec. 20.1. Sec. 20.2. Sec. 20.3. ~ Sec. 20.4. Sec. 20.5. EXHIBIT B Construction Water. Use of Fire Hydrants. District fire hydrants may be used to supply construction water or other temp::.rary water in the It'anner provided in this article. Application. Any person desiring to utilize a fire hydrant for construction or other temporary water use shall file an application for installation of a construction rreter on fOITilS provided by the District. [)(:;!p:Jsit. A dePJsit shall be [E-id the District at the ti.rre of the application which shall be used for the follcwing purposes: A dep::>sit against loss or darmge to the construction rreter or hydrant, which shall be refunded if there is no loss or damage. A fee for installation, which shall not be refW1dable. A "use" fee to be put into an account kept for the purpose of repairs on hydrants within this District. A deposit for water charges. The dep:Jsi t will be refunded ufOn return of the rreter in gcx:xl condition less the rental fee, the installation charge and the cost of water used. No interest shall be paid on the arrount refunded. (RESOLUTION NO. R84-2 dated January 23, 1984) Water Rates. Water used through a construction rreter shall be established by the District. Location of Meter. The meter shall be la:::ated on the fire hydrant designated by District. The applicant may nove the construction IlEter within the sutxlivision ooundaries only after permission has been obtained fran the District. Applicant shall not nove the rreter fran one subdivision to another. If relc:cation fran one subdivision to another is required, this shall be aCe<::iTplishcd by a District employee at a charge established by the District. -20-1-